On -Site Wastewater Disposal System Permit
Permit Number: OSP201122
Work Type: Septic Upgrade
Tax Code Number: 01112286000
Site Legal Address: WARD LT 7 G:2222
Site Mailing Address: 6990 PENNY ROSE CIR, Anchorage
Owner: SHANDY JEDRECK
Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
�o
c
Ur
v
Dcpartment
Lot Size in Sq Ft:
Total Bedrooms:
5/29/2020
5/29/2021
42134
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By:
Date:
Issued By: Date
0
MUNICIPALITYIPALMUNICIPALITYOF /ANCHORAGE � ')
r
Development Services Department Phone: 907-343-7904
�V..-�
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 011-122-86
Property owner(s) JED SHANDY
Mailing address 6966 PENNY ROSE CIR ANCH AK
Site address 6966 PENNY ROSE CIR
Legal description (Sub'd., Block & Lot) WARD LOT 7
Day phone
Legal description (Township, Range & Section)
Lot Size 42,134 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
(® all that apply)
Absorption Field M
Septic Tank
El
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
APPLICATION IS AN:
Initial El
Upgrade ❑
Renewal ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
TYPE OF DWELLING:
Single Family (SF) 0
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance:
I certify that the above information is correct. I further certify that this is' in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: -414. ®U Waiver Fees:
Date of Payment: 511Q I aO Date of Payment:
Receipt Number: 61q!/.� Receipt Number:
Permit No. nl51 ice- Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
COVID-19
25% DISCOUNT APPLIED
May 29, 2020
Municipalities of Anchorage
Departments of Health and Human Services
P.O. Box 196650
Anchorage, Alaska 99519-6650
Fax 249-7847
Re: Septic Permit
Legal: WARD LOT 7
To Whom it may concern:
This is a request for a septic permit on the above referenced lot which is serviced
with a AWWU water line. From the soils logs done for the subdivision 3 test holes
were done with excellent soils, typical for Sand Lake. All of the 3 soil logs show
sand with a perc rates less than 1 min/inch, plus a sieve sample has been done which
shows over 70 percent sand. A simple gravity flow, deep trench has been designed
for this permit. The lot slopes to the south property line at about 5-8 percent then
runs east to the storm drainage pond on the next lot. The lot appears to have been
contoured recently due to no vegetation just a bare lot. No cut banks or slopes
greater than 25 percent are with 100 feet of the site. This new system will no impact
any of the surround properties.
Sincerely
Michael N. Anderson, P.E.
4661 Natrona
Anch, Ak 99516
Ph 727-8864
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201122, Deb Wockenfuss, 05/29/20
SEPTIC FIELD SECTION
DESIGN CRITERIA:
5.0' EFFECTIVE
4 BDRM X 150 = 600 GPD
SOILS = 600/1.2 = 500 GPD
500 GA/10 = 50'
2.0' WIDE
50' LONG
(1) TRENCH
9.0' DEEP
18
(TH#13)
3.5
SP
ORG 1.5'2.0'
-9.0
-4.0
MOUND OVER
FILTER FABRIC
SEWER ROCK
3,3(
GRADE
1"=50'
PROPOSED
WATER LINE
PROPOSED
HOUSE
SCALE:
DJRDRAWN:
DATE:
WARD LOT 7
Anchorage, Alaska
JEB SHANDY
5/17/2020
PROPERTY LINE
5.9' DRAINAGE
EASEMENT
15' DRAINAGE
EASEMENT
DRAINAGE BASIN (DRY)
10' UTILITY
EASEMENT
1250 GALLON PLASTIC
SEPTIC TANK W/ 20"
RISER
CO CO MT
DCO
CO
TCO
SEPTIC AREA
FROM TEST
HOLE DATA
PERC RATE FOR
THESE LOTS
WAS 1 MIN./ INCH
BY GARNESS
ENG.
TH#13
TH#14
TEST HOLE #13-15 FROM
SUBDIVISION SEE MOA
FILE, ALL PERC WERE 1
MIN/INCH
LOT SERVICED BY AWWU WATERLOT SE
RVI
CE
D BY A
W
W
U
WATE
R 5-8% SLOPE TYP.5-8% SLOPE TYP.CO
26.7'6% SLOPE TYP.
NO CUT BANKS
OR SLOPE >25%
WITHIN 50'
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201122, Deb Wockenfuss, 05/29/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201122, Deb Wockenfuss, 05/29/20
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water d Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: May 30, 2008
Expiration Date: May 30, 2009
Permit Number: SWO80064 Parcel ID: 011-122-86
Legal Description: WARD LOT 7
Design Engineer: 0014 ANDERSON ENGINEERING Site Address: NHN PENNY ROSE CIRCLE
Owner Name: BRENDAN & REBECCA MCKEE Lot Size: 42134 SO. FT.
Owner Address: PO BOX 221862 Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE, AK 99522 -
This permit is for the construction of:
n Disposal Field [?] Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By.
IMP
i
Date: 6- Z 09-
Municipality of Anchorage
-�\ Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 011-122-66
Property owner(s) Brendan & Rebecca McKee Day phone
Mailing address P.O. Box 221662 Anchorage, AK Zip Code 99522
Site address WAN Penny Rose Circle Anchorage, AK Zip Code 99516
Legal description (Sub'd., Block & Lot) Lot 7, Ward subdivision
Legal description (Township, Range & Section)
Lot Size 42.134 Sq. Ft.
THIS APPLICATION IS FOR (® all that apply):
Absorption Field El
Septic Tank
Holding Tank ❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms Four (4)
THIS APPLICATION IS AN:
Initial
Upgrade
❑
Renewal
❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: V{6 — Waiver Fees:
Date of Payment: `� r✓/?8 Aq
gLT
Receipt Number. & 7 ✓ /
(Rev. 11/05)
Date of Payment:
Receipt Number.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
May 28, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 7, Ward Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 7, Ward Subdivision intends to construct a new four-bedroom home
on the lot. We are therefore requesting a permit be issued for the construction of a new
septic system to accommodate the home. The subdivision is served by the AWWU
water system. The attached Site Plan and backup documentation identify the location
and configuration of the proposed septic system along with the alternate site. No
existing wells or septic systems are closer than 100' from the proposed septic system.
Drainage arrows are shown on the site plan showing the grade and direction of flow on
the lot. The drainage pattern will not be changed as a result of this project.
The test holes placed on the tract in the area of the absorption trench and alternate site
indicated clean sand (SM/SP/SW) material with some silt. The percolation rate of the
soil was determined to be less than 1 minute per inch. More than 50% of the soil
particles pass the No. 4 sieve and a sand liner is not required. No groundwater was
found during the placement of the test holes and none was noted during the monitoring
period. An application rate of 1.0 gallons per day per square foot was used in the
design of the absorption system. We are proposing to place a new 1,250 -gallon septic
tank and a 50' long by 3' wide by 6' effective depth absorption trench to treat and
dispose of the effluent generated in the house. The elevation of the distribution line in
the absorption trench will be 4' below the surface and the total depth will be 10'. A
minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption
trench and 4' over the septic tank.
The ground surface on the lot in the area of the absorption trench slopes from the south
to the north at a grade of 2% to 5%. The new trench will be constructed parallel with
the slope as much as possible in conformance with Municipal requirements. The new
Lot 7, Ward Subdivision
May 28, 2008
Page Two
septic system will be constructed a minimum of 100' from all wells and any surface
water and 10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any tots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
14"- . Lal�
Michael E. Anderson, P.E.
Attachments
°_ 19; 1
I
ME Esmt
uj
No
- w
0
q
IL
V)
c;
a,
Lot 1
10
VACANT
r4
40,168 C
00
sq.ft.
Lot 9
�j
CA
ALot 8
0
IC:
I;U
45,681
sq.ft.
IR
40,155
I
r
I
0
I
ICA
m
sq.ft.
1--I
u.0:
":t
S0713'36"E
Ix
49.97'
IM
Im
<
I
�7
11a.o1'—
Hanks Subdivision
Lot 2
40,262
sq.ft.
VACANT
Lot 3
249.83
— PENNY
--- — - - — - — - —
S89151,1 329.76'-- '0 - — - — aRROSECLE
A 249.69'
11 315' 134.00
C2 00'13'36'E
0!, 36'E � �5'GasEEsmt
50.03'
>2
Lot 4
VACANT
Lot 5
�10'
ME Esmt
uj
- w
0
V)
q
VACANT
Z
Lot 6
Lot 9
�j
CA
ALot 8
0
Lot 7
45,681
sq.ft.
rq
40,155
of
r
I
0
0
m
sq.ft.
rq
u.0:
":t
f
'r�
10' Utility Esmti—�, -- —
Ratcliffe i Subdivision
50*
(City lWater)3
2 -- I
0_
AREA PLAN
SCALE 1' = 100'
U)
uj
>1
V)
Z
0
0
<
PENNY
ROSE
CIRCLE
242.5X
Is. Cos
fa8pMent . X239.1 WARD SUBDIVISION
LOT 7
r1--�
\i \
\* \ 42,134 S.F.
1 \
Four \
Bedroom \ o
Home \�
\°ce
\
\7
\
\
1,250 Gallon \
Septic Tank \\
OTP15 �\
1; 50' Long x 3' Nide / \
6' Effective Depth \
gysorption Trench / \
®TP 14 I \\
K I \
Alternate
SiteIi \
Site\
®TP13 \\
1100' Set Back \
From Settlement
Pond \
---------------------- ---- ---------1
� 10' T. k E. Easement
•��P'(�, OF . ,•,••�� X245 X224.1
.... 49th :t •�
SITE PLAN
��;M[CHAEL E. AtIDERSOH �' �
�i No. cE-saet ' NJ SCALE 1' = 40'
•�1 .$7—J O-0 1-
LOT 7, WARD SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home Deep Trench System
Perc. Rate: < 1 Min./Inch 1,250 Gallon Septic Tank
Application Rate: 1.0 GPD/SF 6' Drainfield Rock
4 Bedrooms X 150 GPD/1.0 GPD/SF (Application Rate) = 600 SF Absorption Area
600 SF/12 SF/LF = 50 LF Trench Length
THEREFORE: Construct a 50' Long x T Wide x 6' Effective Depth Aborption Trench at the
Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth
to be 10' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide
2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area.
Natural
Backfill
3'6"
Geotextile
Fabric
6" 4" Perforated
PVC (Holes Down)
Fon
3'
Drainfield Rock
TYPICAL DEEP TRENCH SECTION
(NO SCALE) `4
NOTE: Grade Area Over Trench to Drain Away. : a
Minimum 6' Separation From Bedrock. :.,..a
Minimum 4' Separation From Groundwater. 7�1✓�
Minimum 100' Separation From Private Wells in the Area.
Minimum 1 00'Separation From Surface Water or Streams..�i�
Minimum 10' Separation From Water Service Line. d
49th •.':
No. CE4381
1
2
3
4
5
6
7
8
9
10
h
17
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION
ON-SITE WATER AND WASTEWATER PROGRAM
4700 SOUTH BRAGAW ANCHORAGE, AK 99519
PROJECT #: SOILS LOG - PERCOLATION TEST
PERFORMED FOR: LanTech.Inc. DATE PERFORMED: 2/17/05
LEGAL DESCRIPTION: Lot 7_ Johnston Subdivision
TEST HOLE # 13 SLOPE
[oil
OL
Brown and Orange
WAS GROUNDWATER
ENCOUNTERED? NO S
L
IF YES, WHAT DEPTH? 0
DEPTH OF WATER NoneP
AFTER MONITORING: E
DATE: 2/28/2005
•'P..:. MDUM Luuawrl
No. ¢.c381
BOH 18'
SITE PLAN .
N
See Site Plan
See Site Plan
READING DATE
GROSS
TIME
NET
TIME
SP
t'.
Start 2/18
11:45
Sloughing Sidewalk
6.88"
1
.5% Silt
,':.••"';'
Dr
.10"
Recharge
11:57
6.88"
2
12:07
10
Dr
.10"
Recharge
12:08
6.88"
3
12:18
10
Dr
OF
v..
�c�
•`....:
49th
0
WAS GROUNDWATER
ENCOUNTERED? NO S
L
IF YES, WHAT DEPTH? 0
DEPTH OF WATER NoneP
AFTER MONITORING: E
DATE: 2/28/2005
•'P..:. MDUM Luuawrl
No. ¢.c381
BOH 18'
SITE PLAN .
N
See Site Plan
See Site Plan
READING DATE
GROSS
TIME
NET
TIME
DEPTH TO
WATER
NET
DROP
Start 2/18
11:45
6.88"
1
11:55
10
Dr
.10"
Recharge
11:57
6.88"
2
12:07
10
Dr
.10"
Recharge
12:08
6.88"
3
12:18
10
Dr
PERC RATE: -1 MIN./INCH PERC. HOLE DIAMETER:
TEST RUN BETWEEN 4.0 FT. AND 5.0 T. .
COMMENTS: Test Hole Pre Soaked Prior to Percolation Test.
TEST PERFORMED BY: AH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/28/2005
2
3
4
5
6
7
8
9
17
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION
ON-SITE WATER AND WASTEWATER PROGRAM
4700 SOUTH BRAGAW ANCHORAGE, AK 99519
S01
PROJECT #: LS LOG -PERCOLATION TEST
PERFORMED FOR: LanTech.Inc. DATE PERFORMED: 2/17/05
LEGAL DESCRIPTION: Lot 7. Johnston Subdivision
TEST HOLE # 14
OG
OL
Brown and Orange
SP
Sloughing Sidewalls
.5% Silt
a
d
WAS GROUNDWATER
ENCOUNTERED? NO S
L
IF YES, WHAT DEPTH? 0
DEPTH OF WATER None P
AFTER MONITORING: E
DATE: 2/28/2005
BOH 18'
SITE PLAN
N
See Site Plan
See Site Plan
READING DATE
GROSS
TIME
NET
TIME
DEPTH TO
WATER
NET
DROP
Start 2/18.
12:52
6.88-
1
13:02
10
Dr
.10 -
Recharge
13:03
6.88-
2
13:13
10
Dr
.10"
Recharge
13:14
6.88-
3
13:24
10
nry
in -
PERI: RATE: -1 MIN./INCH PERC. HOLE DIAMETER:
TEST RUN BETWEEN-3.3—FT. AND. 4.5 T.
COMMENTS: Test Hole Pre Soaked Prior to Percolation Test.
TEST PERFORMED BY: AH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/28/2005
2
3
4
J
5
7
3
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION
ON-SITE WATER AND WASTEWATER PROGRAM
4700 SOUTH BRAGAW ANCHORAGE, AK 99519
PROJECT #: SOILS LOG — PERCOLATION TEST
PERFORMED FOR: LanTech Inc. DATE PERFORMED: 2/17/05
LEGAL DESCRIPTION: Lot a Johnston Subdivision
TEST HOLE # 15
OG
OL
Brown and Orange
SP
Sloughing Sidewalls
Gap Graded
<5% Sitt
WAS GROUNDWATER
ENCOUNTERED? NO
S
NET
TIME
L
IF YES, WHAT DEPTH?
0
DEPTH OF WATER
None
P
AFTER MONITORING:
E
DATE: 2/28/2005
13:50
Mous EANX a
No. CEAm
BOH 18'
SITE PLAN
N
See Site Plan
See Site Plan
READING DATE
GROSS
TIME
NET
TIME
DEPTH TO
WATER
NET
DROP
Start 2/18
1340
6.88'
1
13:50
10
Dr
-10"
Recharge
13:51
6.88"
2
14:01
10
Or
.10"
Recharge1
14:02
6.88"
31
14:12
10
Dry
.1 -0 -
PERI: RATE: .1 MIN./INCH PERC. HOLE DIAMETER: 8*
TEST RUN BETWEEN --i _0FT. AND 5.0 T.
COMMENTS: Test Hole Pre Soaked Prior to Percolation Test.
u1 ( 33
TEST PERFORMED BY: AH I, MICHAEL F. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL.GUIDELINES ON THIS DATE: 2/28/2005