Loading...
HomeMy WebLinkAboutDAVISON LT 2S I. AC)k%.0 ac\a�0739) GAA Hal• ' GR' 4TER ANCHORAGE AREA BOROL'— i OL,ARTMENT OF ENVIRONMENTAL QUALI, nn 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 2798686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM 31�i - /� MAILING ` NAME �4' T O. TrfLi91 ADDRESSQOX,?,/,� ,%%� /Pif/!y PHONE:'- of` DESCRIPTIO SEPTIC TANK: .J f17 Lzq a )smn DISTANCE FROM WELL / � MATERIAL-f'r��G COMPARTMENTS . / 97 2 .f";VzVe -jr LIQUID LIQUID CAPACITY �OOG GALLONS. INSIDE LENGTH 1i INSIDE WIDTH DEPTH �- SEEPAGE SYSTEM: SEEPAGE PIT: i i / NUMBER OF PITS OUTSIDE DIAMETER ✓ OR WIDTH �+�' LENGTH �•-1 DEPTH / LINING MATERIAL Cil C������-�`�"" . DISTANCE FROM WELL / 9 , BUILDING FOUNDATION NEAREST LOT LINE a0 TZ' FiS�/7' TOTAL EFFECTIVE ABSORPTION AREA CWALL AREA) '�-3 '✓ SO. FT. TILE DRAIN FIELD: DISTANCE FROM WELI NUMBER OF BETWEEN LINES AREA SO. FT. LENGTH OF EACH LOT LIN TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: ��✓�6`d 4aWr DISTANCE FROM WATER TYPE,66,z DEPTH So �" , BUILDING FOUNDATION. SAMPLE NEAREST NEAREST SEPTIC i SEEPAGE / OTHER N«� LOT LINE �?U rf�/<o.Y. � f , SEWER LINE Z/,TANK 70 , SYSTEM PS , CESSPOOL -e . SOURCES "� DIAGRAM OF SYSTEM DISTANCES: ,00 7A c raw Anf.s 7i ' �...•r terra✓ f«j�ao i-fA17T eta'!�N Ja1l� 7JNt�4Aty ; DATE Z1,10'1Z9/'-2� APPROVED --' G.A.A.B. GREATER ANCHORAGE AREA BOROUGV� DEPr`'MENT OF ENVIRONMENTAL QU/ TY CASE 3500 TUDOR ROAD --� ANCHORAGE, ALASKA 99502 Performed For Robert D. Thomas Legal Descript on: Lot71 Block Subdivisione Performed 6/15/72 This Form Reports Soils -9 "— erco anon est Depth Sec 33 TS 12NR3W reet Soil Characteristics 2 3 -- Gray and tan silty sandy gravel GM ) ' 4 Gray sandy gravel, slightly silty. �7+7 �- Gray clean sandy gravel from 6' to 7.5 �� I w/silty sand seams and sand below 7.5' ? i 6 I 7 g 9 — 10 Was Ground Water Encountered? No 1p, .o If Yes, At What Depth? ReadingI Date I Gross Time Net Time IDepth to H2O I Net vercolatio.. R.E. Minute - Proposed Insta atTT o . Seepage Pit Depth Of Inlet Depth To BottomiOfFPitd COMMENTS: ft r Trenc 130 sa. of drainage area is required ner 6alr� 'vu DY:National Testinc Date:- 7::.7o ate:-__.... ._. GREh, ER ANCHORAGE AREA BOK./UGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6.650 ANCHORAGE. ALASKA 99502 TELEPKONE 279.6686 2187 PERMIT NO. SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT t ��� / /� S• MAILING ADDRESS XS " J PHONE / /` J \ INSTALLATION LOCATION ��•�/^ �-Sr '^ r ' "t //� �` H 5Z 7 LEGAL DESCRIPTION /'�> �T nI " J r( �/ ,�3 T/--Lv Pi'zo 5zll. yy (t INSTALLATION OF: SEPTIC TANK X SEEPAGE PIT DRAIN FIELD �pJG OTHER TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH 7� TO BE INSTALLED BY SOIL TEST RESULTS i� /�' NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED / y 7L FINAL INSPECTIONI 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE l('TYPE 5 ycer ` Q�''PAGE AREA SIZETYPE MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT cI / DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK 'SEEPAGE PIT CI / DRAIN FIELD I TO NEAREST LOT LINE. WELL TO SEPTIC TANK t ' SEEPAGE PIT �C DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD SEPTIC TANK, o1S ' SEEPAGE PIT �G O DRAIN FIELD TO RIVER. LAKE. STREAM. CASPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. - - 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FI ED WITH AIRTIGHT REMOVABLE "Cs ----- GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUT RITY Oy I. LICENSED bcSIGNER I CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE z APPLICANT'S SIGNATURE c Y� +�'•�+� R&M ENGINEERING & GEOLOGICAL CONSULTANTS 229 EAST 51st. AVE. — P.O. BOX 6087 _ ANCHORAGE, ALASKA 99503 r� TELEPHONE 907-279-0483 TELEX 090-35419 a Civil Engineers Geologists Land Surveyors JAMES W. ROONEY, P.E. RALPH R. MIGLIACCIO MALCOLM A. MENZIES. P.E., L.S. Engineering Geologist JAMES H. WELLMAN. P.E. June 19, 1972 R & M No. 26527 RECEIVED Mr. Robert Thomas Star Route A Box 245 JUNG . ly/Y Pm Anchorage, Alaska 99507 GREATER ANCHORAGE AREA BOROUGH DEPT. Of ENVIRONMENTAL QUALITY RE: Test Hole and Soil Log Report for Sanitary System W1-2, N=, Lot 182, Section 33, T12N, R3W Seward Meridian Dear Mr. Thomas: We are submitting herewith the test boring results and our comments re- garding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of June 14, 1972, and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strick- land of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 182 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor -mounted backhoe and the test hole was extended to a total depth of li feet below ground surface. One sample was recovered from the bottom of the test hole and retained for grain size analysis. The sample will be held in storage, up to approximately one month, for possible testing before it is discarded. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M ENGINEERING & GEOLOGICAL CONSULTANTS V �..�d `I James W. Rooney JWR:wb cc: Greater Anchorage Area Borough T.H.-1 6-15-72 .0 " d D b. �.'•9 b� SILTY SANDY GRAVEL W/TRACE ORGANICS (GM) �] 2 b Do SANDY GRAVEL (G W) J. ;::p! W/COBBLES g 5 0 0 ..a SAND, Grey (SW) •OO SANDY GRAVEL (GW) g W/COBBLES 0.• 0. e. `0 M 3.0' 6.0' %pRr^ 6.5' 11.0' No water table \— Note: Hole excavated with tractor mounted backhoe. Robert Thomas Property JEnglneeringaGeologloal Consultants LOG OF TEST BORING .►AIw eANKe ALASKA duN[AU Anchorage Alaska DATE 6-15-72 SCALE 1" =2' OWN BY GAW ICHKO BY WED IPFtOJ. No. 26527 DWO No. A-01 I WE/9 r� / -Rbl/ y i fsi 5. LEGAL DESCRIPTION / g A DEPT. G. - --CTION MUNICIPALITY OF ANCHORAGE ��, „//,��O'sr- DIAL l ; • DEPARTMENT OF HEALTH & ENVIRONMENTAL PROT ECTIDN� 825 L Street • Anchorage, Alaska 99507 ,iild25'19 9 p ENVIRONMENTAL ENGINEERING DIVISION NUMBER OF BEDHOOAIS Telephone 264-4720 RECEIVED. REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER ❑ MULTIPLE FAMILY PHONE Er -41n7S'G r D oL3 q -a MAILING ADDRES _ -r A. Q�X qI 7SO 7 ,, V y� PROPERTY RESIDENT (11 different from ^above) 1 PHONE i Nt 2. BUYER by this Department. PHONE MAILING ADDRESS 3. LENDING INSTITUTION PHONE F M C ncE MAILING ADDRESS G 3 RA Al c 4. REALTOR/AGENT.A16 AJ C PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION / g 3O STREET LOCATION L 117- -2- AVISO SO p 6. TYPE OF RESIDENCE NUMBER OF BEDHOOAIS D ---`SINGLE FAMILY ❑ One ❑ Four ❑ Other ❑ Two ❑ Five ❑ MULTIPLE FAMILY C§ --Three ❑ Six 7. WATER SUPPLY Za" INDIVIDUAL' ' ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) / /Sp77 8. SEWAGE DISPOSAL SYSTEM G;K INDIVIDUAL/ON-SITE" "If individual/on-site, give installation date /97z If system is over two (2) years old an adequacy test is required ❑ PUBLIC UTILITY by this Department. NOTE: THE IN 7EEQZE PROCESSING CAN BE INITIATED. (� o. t y C) THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS 1 TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR INSPECTION APPOINTMENTS DATE RECEIVED , TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY❑ ❑ ,MULTIPLEFAMILY NUMBER OF BEDROOMS ONE ❑ THREE ❑ j FIVE ❑ OTHER ❑ TWO. ❑ .', FOUR ❑', SIX 2. WATER SUPPLY ❑ INDIVIDUAL - ❑ COMMUNITY ❑ PUBLICUTILITY - Connection Verified PERMITNUMBER DEPTH OF WELL .. . DATE DRILLED LOG RECEIVED I 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER GATE INSTALLED (o INSTALLER I ❑Septi/c/ �T/a�n/k� or ❑Holding Tank'"'"' Size: /600 If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK ' y MANUFACTURER TOTAL ABSORPTION AREA ,, MATERIAL r j 4. DISTANCES WELLTO: Septic/Hoiding Tank Absorption Area Sewer Line - Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS 6"APPROVEDFOR BEDROOMS '^ ❑ CONDITIONAL APPROVAL (letter must accompany certificate) i -. ❑ DISAPPROVED - DATE BY( s LEGAL DESCRIPTION 72-010 (Rev. 7178) C s - June 29, 1979 Mr. Robert Thomas SRA Box 245 Anchorage, Alaska 99507 Re: Adequacy Test for Exist Davidson Subdivision. Dear Mr. Thomas: At your request our office c test on your existing septic location during the period a that your septic system cons and seepage pit. The septic tank had not been test. Since the -l -bedroom h time of the test. a normal d_., field is assumed. :K BENNY'S AND 3E CESSPOOL PUMPING tar Route A Box 144 HORAGE, ALASKA 99502 14.2632 or 349.1131 eusrwEhs ahoen ho. AghE o•r 3 +97q hA4E I]AD!DRESMs COD. tlAPOE Oh ACC r. 4CSE RET D. PAOO b i a, i -... __ TAX i — i w 11ECErvFC �r TOTAL p P or r All claims and returned good, MUST be 11083 a=0mWnlad by this bill �—_/_Cy -- _--�— _—SE91E8 lOB /��i f In accordance with the Anchorage Municipal Code, Chapter 15.65, Waste Water Disposal Regualtions, any on-site sewage disposal system "shall have adequate capacity to properly dispose of the maximum daily sewage flow." The maximum daily flow is computed at 75 gallons per capita -day (gcpd). Since "the population of dwellings shall be estimated at two persons per sleeping room," the maximum daily sewage flow for your -bedroom house is 450 gallons per day (gpd). To test the soil absorption capacity as well as the surge capability of your system, 110 percent of the mbximum daily flow or 500 gallons of clear water was added in*50-gallon increments to the seepage pit. The water was obtained from your on-site private well at its maximum sustained rate of about 4 gallons per minute (gpm). The liquid levels were monitored closely to detect any backup in the septic system. Mr. Robert Thomas June 29, 1979 Page -2- The attached Table of Test Data represents the depths of liquid in the septic tank and seepage pit, and the quantities of water added. The septic tank was determined £o be 9.3 feet deep (bottom of tank to ground surface) with an initial depth of 4.1 feet in the tank. The seepage pit was measured to be 9.3 feet deep with an initial depth of 0.5 feet. Ground elevation at the septic tank standpipe is approximately 1.7 feet higherthan at the seepage pit standpipe. The attached Summary of Test Results indicates that the liquid level in the seepage pit at the beginning of testing on Day 2 fell to 0_05 feet below its initial static level on Day 1, during a recovery period of 24 hours. On Day 3, the level had fallen to �•Ofeetbelow its static level on Day 2, during a recovery period of 24 hours. This results in an average rate of fall of 0.02 feet per hour. The level in the seepage pit at its highest level during the test (1.0 feet) was approximately 4.7 feet below the liquid level in the septic tank. Based on two days of testing, a percolation rate for your existing septic system of approximately 500 qpd is indicated. Since an on-site sewage disposal system for a 3 -bedroom dwelling must be capable of disposinq of 450 gallons of sewage per day, your septic system appears to be functioning satis- factorily at this time. Many factors affect the operation of a soil absorption type of sewage disposal system. Soil type, qroundwater depth, aqe and history of maintenance of the system. and types of waste are a few. This test has been performed in an attempt to model actual soil absorption capabilities of your septic system under normal useaqe by considerinq the deqree of saturation of the leach field and surge loads that might be imposed on the system. This test can only evaluate apparent performance at a given point in time, and cannot determine either the condition of the leach field, seepage pit or other components of the septic system, or the depth of the water table. We appreciate the opportunity given to perform this adequacy test. If you have any questions regarding this test, please contact this office.OFAt- ..... \\>t\' .. q Very truly yours, ;�.�P�.••"'•'A CgS`1 ALASKA SOILS INVESTIGATIONS to hen D. Shrader, P.E. Project Manager 4 �lc Stephen D. Shroder 4 No. 4118 • E '•. C Vi 4'-'•• a--..•'� Fes.. Mr. Robert Thomas JUne 29 . 1979 Page -3- SUMMARY OF TEST RESULTS D5001 D5t02 Daa 3 Wtr Added. Seepage Pit Rise in. Seepage Pit- 0.50' 0.55' Rise in Septic Tank 0.00' 0.00' Gallons Wtr Added per Ft of Rise (gal/ft) 1000 1000 Recovery Time between 24 24 Test (Hours) Drop in Pit during 0.55! 0.55' Recovery Average Rate of Fall (ft/hr) 0.02' 0.02' Average Absorption Rate (gal/day) 500 500 i Adequacy Test for PXiating Septic System Owners Mr. Robert Thomas Project No. 02779 Address: SRA Boz 245, Anchorage, Alaska 99507 Legal Description: Lot 29 Davidson Subdivision Componente of Septic. Syatem:•1000-gal septic tank; .seepage pit. Number of Bedrooms: 3 Occupied prior to test: Yes XX No Now long vacant: na Last pumped: April 1979 Test performed by: S. Shrader Initial Static Levels:. Septic Tank 4.1' TEST DATA Water meter/S.N. 22812186 Seepage Pit 0.5' Time ^ • + .Liquid Depth • ft- ** Water Added, gal Meter Reading, gal Remarks Seepare Pit. 2:48 6.0' 9.4' -0- 11,039 6/26779 Initial leve 2:53 " 9.4' -0- 11,039 Start test. 3:04 " 9.15' 50 11,089 3:17 " 9.05' 50 11,139 3:31 " 9.05' 60 11,199 3:41 9.00' 40 11,239 3:53 8.95' 50 11,2.89 4:04 8.95 50 11,339 4:18 " 8.95 50 11,389 4:29 " 8.92 50 11,439 4:41 it 8.90 50 119489 4:54 it 8.90 50 119539 End test. 500 gal 500 -gal 202 6.01 '9.45' -0- 119539 6/27/79 Initial lev ] 2:48 to 9.201' 50 11,589 3:00 9.10' 50 119639 3:12 ' 9.05' 50 11,689 3:26 " 9.05' 50 11,739 R bwner:•Mr. Robert Thomas w Project No. 02779 Legal Description: Lot 2,' Davidson Subdivision TEST DATA (Cont'd) Time Li i Depth, t Water Added, gal Meter Reading, gal Remarks Septic Tan Seepage Pit 3:38 6.0' 8.95' 50 11,789 3:50 of 8.95' 50 110839 4:02 8.95' 50 11,889 4:14 " 8.92' 50 11,939 4:27 8.90' 50 11,989 4:40 " 8.90' 50 12,039 es . Day 2. 2:30 6.0' 9.45' _0_ _ 'heck levels ,/28/79