HomeMy WebLinkAboutDAVISON LT 2S I.
AC)k%.0 ac\a�0739)
GAA Hal• ' GR' 4TER ANCHORAGE AREA BOROL'— i
OL,ARTMENT OF ENVIRONMENTAL QUALI, nn
3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 2798686
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
31�i -
/�
MAILING `
NAME �4' T O. TrfLi91 ADDRESSQOX,?,/,� ,%%� /Pif/!y PHONE:'- of`
DESCRIPTIO
SEPTIC TANK:
.J f17
Lzq a )smn
DISTANCE FROM WELL / � MATERIAL-f'r��G COMPARTMENTS .
/ 97 2 .f";VzVe -jr LIQUID
LIQUID CAPACITY �OOG GALLONS. INSIDE LENGTH 1i INSIDE WIDTH DEPTH �-
SEEPAGE SYSTEM: SEEPAGE PIT:
i i /
NUMBER OF PITS OUTSIDE DIAMETER ✓ OR WIDTH �+�' LENGTH �•-1 DEPTH /
LINING MATERIAL Cil C������-�`�"" . DISTANCE FROM WELL / 9 , BUILDING FOUNDATION
NEAREST LOT LINE a0 TZ' FiS�/7' TOTAL EFFECTIVE ABSORPTION AREA CWALL AREA) '�-3 '✓ SO. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELI
NUMBER OF
BETWEEN LINES
AREA SO. FT. LENGTH OF EACH
LOT LIN
TOTAL LENGTH
OF LINES
IN. TOTAL EFFECTIVE
DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE
WELL: ��✓�6`d 4aWr DISTANCE FROM WATER
TYPE,66,z DEPTH So �" , BUILDING FOUNDATION. SAMPLE NEAREST
NEAREST SEPTIC i SEEPAGE / OTHER N«�
LOT LINE �?U rf�/<o.Y. � f , SEWER LINE Z/,TANK 70 , SYSTEM PS , CESSPOOL -e . SOURCES "�
DIAGRAM OF SYSTEM
DISTANCES:
,00 7A c raw
Anf.s 7i '
�...•r terra✓
f«j�ao i-fA17T
eta'!�N Ja1l�
7JNt�4Aty ;
DATE Z1,10'1Z9/'-2� APPROVED --'
G.A.A.B.
GREATER ANCHORAGE AREA BOROUGV�
DEPr`'MENT OF ENVIRONMENTAL QU/ TY CASE
3500 TUDOR ROAD --�
ANCHORAGE, ALASKA 99502
Performed For Robert D. Thomas
Legal Descript on: Lot71 Block Subdivisione Performed 6/15/72
This Form Reports Soils -9 "—
erco anon est
Depth Sec 33 TS 12NR3W
reet
Soil Characteristics
2
3 --
Gray
and tan silty sandy gravel GM )
'
4
Gray
sandy gravel, slightly silty.
�7+7
�-
Gray
clean sandy gravel from 6' to 7.5
�� I
w/silty sand seams and sand below 7.5'
? i
6
I
7
g
9
—
10
Was Ground Water Encountered? No 1p,
.o
If Yes, At What Depth?
ReadingI Date I Gross Time
Net Time IDepth to H2O I Net
vercolatio.. R.E.
Minute -
Proposed Insta atTT o . Seepage Pit
Depth Of Inlet Depth To BottomiOfFPitd
COMMENTS: ft r Trenc
130 sa. of drainage area is required ner 6alr�
'vu DY:National Testinc
Date:-
7::.7o
ate:-__.... ._.
GREh, ER ANCHORAGE AREA BOK./UGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3500 TUDOR ROAD POUCH 6.650
ANCHORAGE. ALASKA 99502
TELEPKONE 279.6686
2187
PERMIT NO.
SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT
NAME OF APPLICANT t ��� / /� S• MAILING ADDRESS XS " J PHONE /
/` J \
INSTALLATION LOCATION ��•�/^ �-Sr '^ r ' "t //� �` H 5Z 7
LEGAL DESCRIPTION /'�> �T nI " J r( �/ ,�3 T/--Lv Pi'zo 5zll.
yy (t
INSTALLATION OF: SEPTIC TANK X SEEPAGE PIT DRAIN FIELD �pJG OTHER
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH 7� TO BE INSTALLED BY
SOIL TEST RESULTS i� /�' NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED / y 7L
FINAL INSPECTIONI 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE l('TYPE 5 ycer ` Q�''PAGE AREA SIZETYPE
MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT cI / DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK 'SEEPAGE PIT CI / DRAIN FIELD
I
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK t ' SEEPAGE PIT �C
DRAIN FIELD ALSO CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK, o1S ' SEEPAGE PIT �G O DRAIN FIELD
TO RIVER. LAKE. STREAM.
CASPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION S FEET INTO UNDISTURBED SOIL. - -
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FI ED WITH AIRTIGHT REMOVABLE "Cs -----
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
HEALTH AUT RITY
Oy I.
LICENSED bcSIGNER
I CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE z APPLICANT'S SIGNATURE c Y� +�'•�+�
R&M ENGINEERING & GEOLOGICAL CONSULTANTS
229 EAST 51st. AVE. — P.O. BOX 6087 _ ANCHORAGE, ALASKA 99503
r� TELEPHONE 907-279-0483 TELEX 090-35419
a Civil Engineers Geologists Land Surveyors
JAMES W. ROONEY, P.E. RALPH R. MIGLIACCIO
MALCOLM A. MENZIES. P.E., L.S. Engineering Geologist
JAMES H. WELLMAN. P.E.
June 19, 1972 R & M No. 26527
RECEIVED
Mr. Robert Thomas
Star Route A Box 245 JUNG . ly/Y Pm
Anchorage, Alaska 99507
GREATER ANCHORAGE AREA BOROUGH
DEPT. Of ENVIRONMENTAL QUALITY
RE: Test Hole and Soil Log Report for Sanitary System
W1-2, N=, Lot 182, Section 33, T12N, R3W Seward Meridian
Dear Mr. Thomas:
We are submitting herewith the test boring results and our comments re-
garding soil conditions encountered at the subject site. This investigation
was performed in accordance with your request of June 14, 1972, and those
procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strick-
land of the Greater Anchorage Area Borough Department of Environmental
Quality.
A single test hole was put down within the Lot 182 area for the purpose of
defining general subsurface soil conditions for the proposed sanitary system.
Excavation was accomplished with a tractor -mounted backhoe and the test
hole was extended to a total depth of li feet below ground surface. One sample
was recovered from the bottom of the test hole and retained for grain size
analysis. The sample will be held in storage, up to approximately one month,
for possible testing before it is discarded. The final log prepared for the
test hole has been included in Drawing A-01.
Ground water was not encountered in the test hole.
We appreciate being given this opportunity to be of service to you. Should
you have any questions with regard to the above, please do not hesitate to
contact us.
Very truly yours,
R & M ENGINEERING & GEOLOGICAL CONSULTANTS
V �..�d `I
James W. Rooney
JWR:wb
cc: Greater Anchorage Area Borough
T.H.-1
6-15-72
.0
" d
D b.
�.'•9
b�
SILTY SANDY GRAVEL
W/TRACE ORGANICS (GM)
�] 2
b
Do
SANDY GRAVEL (G W)
J.
;::p!
W/COBBLES
g 5
0 0
..a
SAND, Grey (SW)
•OO
SANDY GRAVEL (GW)
g
W/COBBLES
0.•
0.
e.
`0
M
3.0'
6.0' %pRr^
6.5'
11.0'
No water table \—
Note: Hole excavated with tractor mounted backhoe.
Robert Thomas Property
JEnglneeringaGeologloal Consultants LOG OF TEST BORING
.►AIw eANKe ALASKA duN[AU
Anchorage Alaska
DATE 6-15-72 SCALE 1" =2' OWN BY GAW ICHKO BY WED IPFtOJ. No. 26527 DWO No. A-01
I
WE/9
r� / -Rbl/
y i fsi
5. LEGAL DESCRIPTION
/ g
A
DEPT. G. -
--CTION
MUNICIPALITY OF ANCHORAGE ��, „//,��O'sr- DIAL l ;
•
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROT ECTIDN�
825 L Street • Anchorage, Alaska 99507
,iild25'19 9
p
ENVIRONMENTAL ENGINEERING DIVISION
NUMBER OF BEDHOOAIS
Telephone 264-4720 RECEIVED.
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTY OWNER
❑ MULTIPLE FAMILY
PHONE
Er
-41n7S'G
r D oL3
q -a
MAILING ADDRES
_
-r
A. Q�X qI 7SO 7
,, V
y�
PROPERTY RESIDENT (11 different from ^above) 1
PHONE
i
Nt
2. BUYER
by this Department.
PHONE
MAILING ADDRESS
3. LENDING INSTITUTION
PHONE
F M C ncE
MAILING ADDRESS
G
3 RA Al c
4. REALTOR/AGENT.A16
AJ C
PHONE
MAILING ADDRESS
5. LEGAL DESCRIPTION
/ g
3O
STREET LOCATION
L 117- -2- AVISO SO
p
6. TYPE OF RESIDENCE
NUMBER OF BEDHOOAIS
D ---`SINGLE FAMILY
❑ One ❑ Four ❑ Other
❑ Two ❑ Five
❑ MULTIPLE FAMILY
C§ --Three ❑ Six
7. WATER SUPPLY
Za" INDIVIDUAL'
' ATTACH WELL LOG. A well log is required for all wells drilled
❑ COMMUNITY
since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY
depth (attach log if available.) / /Sp77
8. SEWAGE DISPOSAL SYSTEM
G;K INDIVIDUAL/ON-SITE"
"If individual/on-site, give installation date /97z
If system is over two (2) years old an adequacy test is required
❑ PUBLIC UTILITY
by this Department.
NOTE: THE IN
7EEQZE PROCESSING CAN BE INITIATED.
(� o. t
y C)
THIS SIDE FOR OFFICIAL USE ONLY
INSPECTION APPOINTMENTS
1
TIME
TIME
TIME
DATE
DATE
DATE
INSPECTOR
INSPECTOR
INSPECTOR
INSPECTION APPOINTMENTS
DATE RECEIVED ,
TIME
TIME
TIME
DATE
DATE
DATE
INSPECTOR
INSPECTOR
INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY❑
❑ ,MULTIPLEFAMILY
NUMBER OF BEDROOMS
ONE ❑ THREE ❑ j FIVE ❑ OTHER
❑ TWO. ❑ .', FOUR ❑', SIX
2. WATER SUPPLY
❑ INDIVIDUAL -
❑ COMMUNITY
❑ PUBLICUTILITY
- Connection Verified
PERMITNUMBER
DEPTH OF WELL .. .
DATE DRILLED
LOG RECEIVED
I
3. SEWAGE DISPOSAL SYSTEM
❑INDIVIDUAL/ON -SITE
❑PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
GATE INSTALLED
(o
INSTALLER
I
❑Septi/c/ �T/a�n/k� or ❑Holding Tank'"'"'
Size: /600 If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK ' y
MANUFACTURER
TOTAL ABSORPTION AREA
,,
MATERIAL r j
4. DISTANCES
WELLTO:
Septic/Hoiding Tank
Absorption Area
Sewer Line -
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
6"APPROVEDFOR BEDROOMS '^
❑ CONDITIONAL APPROVAL (letter must accompany certificate) i -.
❑ DISAPPROVED
-
DATE
BY(
s
LEGAL DESCRIPTION
72-010 (Rev. 7178)
C s -
June 29, 1979
Mr. Robert Thomas
SRA Box 245
Anchorage, Alaska 99507
Re: Adequacy Test for Exist
Davidson Subdivision.
Dear Mr. Thomas:
At your request our office c
test on your existing septic
location during the period a
that your septic system cons
and seepage pit.
The septic tank had not been
test. Since the -l -bedroom h
time of the test. a normal d_.,
field is assumed.
:K BENNY'S AND
3E CESSPOOL PUMPING
tar Route A Box 144
HORAGE, ALASKA 99502
14.2632 or 349.1131
eusrwEhs ahoen ho.
AghE
o•r
3 +97q
hA4E
I]AD!DRESMs
COD.
tlAPOE Oh ACC r.
4CSE RET D.
PAOO
b i a,
i
-... __
TAX
i
—
i
w
11ECErvFC �r
TOTAL
p P or
r
All claims and returned good, MUST be
11083 a=0mWnlad by this bill �—_/_Cy
-- _--�— _—SE91E8 lOB /��i f
In accordance with the Anchorage Municipal Code, Chapter 15.65,
Waste Water Disposal Regualtions, any on-site sewage disposal
system "shall have adequate capacity to properly dispose of the
maximum daily sewage flow." The maximum daily flow is computed
at 75 gallons per capita -day (gcpd). Since "the population of
dwellings shall be estimated at two persons per sleeping room,"
the maximum daily sewage flow for your -bedroom house is 450
gallons per day (gpd).
To test the soil absorption capacity as well as the surge
capability of your system, 110 percent of the mbximum daily
flow or 500 gallons of clear water was added in*50-gallon
increments to the seepage pit. The water was obtained from
your on-site private well at its maximum sustained rate of
about 4 gallons per minute (gpm). The liquid levels were
monitored closely to detect any backup in the septic system.
Mr. Robert Thomas
June 29, 1979
Page -2-
The attached Table of Test Data represents the depths of
liquid in the septic tank and seepage pit, and the quantities
of water added. The septic tank was determined £o be 9.3 feet
deep (bottom of tank to ground surface) with an initial depth
of 4.1 feet in the tank. The seepage pit was measured to be
9.3 feet deep with an initial depth of 0.5 feet. Ground
elevation at the septic tank standpipe is approximately 1.7
feet higherthan at the seepage pit standpipe.
The attached Summary of Test Results indicates that the
liquid level in the seepage pit at the beginning of testing
on Day 2 fell to 0_05 feet below its initial static level on
Day 1, during a recovery period of 24 hours. On Day 3, the
level had fallen to �•Ofeetbelow its static level on Day 2,
during a recovery period of 24 hours. This results in an
average rate of fall of 0.02 feet per hour.
The level in the seepage pit at its highest level during the
test (1.0 feet) was approximately 4.7 feet below the liquid
level in the septic tank.
Based on two days of testing, a percolation rate for your
existing septic system of approximately 500 qpd is indicated.
Since an on-site sewage disposal system for a 3 -bedroom
dwelling must be capable of disposinq of 450 gallons of sewage
per day, your septic system appears to be functioning satis-
factorily at this time.
Many factors affect the operation of a soil absorption type
of sewage disposal system. Soil type, qroundwater depth, aqe
and history of maintenance of the system. and types of waste
are a few. This test has been performed in an attempt to
model actual soil absorption capabilities of your septic system
under normal useaqe by considerinq the deqree of saturation of
the leach field and surge loads that might be imposed on the
system. This test can only evaluate apparent performance at
a given point in time, and cannot determine either the condition
of the leach field, seepage pit or other components of the
septic system, or the depth of the water table.
We appreciate the opportunity given to perform this adequacy
test. If you have any questions regarding this test, please
contact this office.OFAt-
.....
\\>t\'
.. q
Very truly yours, ;�.�P�.••"'•'A CgS`1
ALASKA SOILS INVESTIGATIONS
to hen D. Shrader, P.E.
Project Manager
4
�lc
Stephen D. Shroder 4
No. 4118 • E
'•. C Vi
4'-'•• a--..•'� Fes..
Mr. Robert Thomas
JUne 29 . 1979
Page -3-
SUMMARY OF TEST RESULTS
D5001
D5t02
Daa 3
Wtr Added. Seepage Pit
Rise in. Seepage Pit-
0.50'
0.55'
Rise in Septic Tank
0.00'
0.00'
Gallons Wtr Added per
Ft of Rise (gal/ft)
1000
1000
Recovery Time between
24
24
Test (Hours)
Drop in Pit during
0.55!
0.55'
Recovery
Average Rate of Fall (ft/hr)
0.02'
0.02'
Average Absorption Rate
(gal/day)
500
500
i
Adequacy Test for PXiating Septic System
Owners Mr. Robert Thomas Project No. 02779
Address: SRA Boz 245, Anchorage, Alaska 99507
Legal Description: Lot 29 Davidson Subdivision
Componente of Septic. Syatem:•1000-gal septic tank; .seepage pit.
Number of Bedrooms: 3 Occupied prior to test: Yes XX No
Now long vacant: na Last pumped: April 1979
Test performed by: S. Shrader
Initial Static Levels:. Septic Tank 4.1'
TEST DATA
Water meter/S.N. 22812186
Seepage Pit 0.5'
Time
^ • + .Liquid Depth • ft- **
Water
Added, gal
Meter
Reading, gal
Remarks
Seepare Pit.
2:48
6.0'
9.4'
-0-
11,039
6/26779
Initial leve
2:53
"
9.4'
-0-
11,039
Start test.
3:04
"
9.15'
50
11,089
3:17
"
9.05'
50
11,139
3:31
"
9.05'
60
11,199
3:41
9.00'
40
11,239
3:53
8.95'
50
11,2.89
4:04
8.95
50
11,339
4:18
"
8.95
50
11,389
4:29
"
8.92
50
11,439
4:41
it
8.90
50
119489
4:54
it
8.90
50
119539
End test.
500 gal
500 -gal
202
6.01
'9.45'
-0-
119539
6/27/79
Initial lev ]
2:48
to
9.201'
50
11,589
3:00
9.10'
50
119639
3:12
'
9.05'
50
11,689
3:26
"
9.05'
50
11,739
R
bwner:•Mr. Robert Thomas
w
Project No. 02779
Legal Description: Lot 2,' Davidson Subdivision
TEST DATA (Cont'd)
Time
Li i Depth, t
Water
Added, gal
Meter
Reading, gal
Remarks
Septic Tan
Seepage Pit
3:38
6.0'
8.95'
50
11,789
3:50
of
8.95'
50
110839
4:02
8.95'
50
11,889
4:14
"
8.92'
50
11,939
4:27
8.90'
50
11,989
4:40
"
8.90'
50
12,039
es .
Day 2.
2:30
6.0'
9.45'
_0_
_
'heck levels
,/28/79