HomeMy WebLinkAboutBAUMER S-3430t
i -
h
r"
r Lynn P. Wallace P.E.
4839 Tampa Circle
1th.:i1VEU Anchorage, Alaska 99.�U4
June 11, 1974
JUN ? 11974 Ahl
Mr. Rolf Strickland
Chief Sanitarian GARB OA1fttc+av°an40"nuou�i�ii"
3»u C Street OLPT.
Anchorage, Alaska 99503
Dear Mr. Strickland; Re: S-3430 Baumer Subdivision
The soils test holes for this subdivision were made to the depth of the
hardpan layer that supports the surficial soil deposits. This depth
ranged from 10-1/2 feet to 12-1/2 feet in the three test holes that
were excavated, as shown on the drawings and test logs which were
submitted.
The hardpan layer is a densly packed layer of non uniformly graded gravel
sand and rockflour, genera* classified as a CP soil. This hardpan layer
generally extends downward fur an additional ten to twenty feet in the
subject subdivision, before bedrock is encountered.
There is no evidence of a static water table on this hillside and all
water seeps observed or reported, occur above the hardpan layer. Wells
In the area are cased to bedrock and extend down approximately 75 to 80
feet or greater from the ground surface. The wells are supplied rrom
water seeping through the fractured bedrock from spurces on the mountains
above.
Utilizing this information, I have determined that deeper excavations would
not provide significantly different data and had the excavator stop after
successfully penetrating the hardpan layer. I therefor submit that the
_hardpan soil continues to a depth exceeding 17 feet and that no static
is
cc Don Lucas
ct
P. Wallace P.E.
9=1STIREd
(OON n
Greater Anchorage Area Borough
Planning Department
3500 Tudor Road
Anchorage, Alaska 99507
Attention: Mr. Wayne Mabry
Subject: Soils Evaluation
Resubdivision of
Addition $2
Dear Mr. Mabry:
4839 Tampa Circle
Anchorage, Alaska 99504
June 2, 1974
and Related Items - Baumer Subdivision,
TR 10, Donald C. Schroeder Subdivision,
The following information concerning the soils conditions for the
proposed Baumer Subdivision located on the Eagle River Road in Eagle
River, is submitted to satisfy the requirements of GAAB Ordinance
No. 112-72A, Chapter 21; and Title 18, Environmental Conservation,
18 AAC 72.060 of the State of Alaska. Test Hole logs and project
location maps follow the text.
SITE LOCATION AND DESCRIPTION. The approximately 4.5 acre parcel
to be subdivided is located five miles east of the Glenn Highway
on the Eagle River Road. The property is overgrown with Alders and
small Birch as a second growth after having been cleared for home-
steading. "The topography is generally sloping to the south
becoming steeper near Hammond Road to the north of the property.
EXISTING YELLS AND SUBSURFACE DRAIN FIELDS. The location of
existing wells on or near the parcel to be subdivided are shown on
the project location map. Water has-been located in this area
approximately 85' to 110' below the surface. Neighboring sub-
divisions (not shown on map) have wells of sufficient capacity to
supply domestic needs. The existance of reliable water sources
in this geological area has been proven sufficiently to Borough,
Officials in the immediate past. Previous chemical and bacterio-
logical testing of existing water sources has indicated that
drinking water quality standards are satisfied.
FIELD EXPLORATION. On May 27, 1974, three(3) testholes were
excavated on siEe to depths of 12-1/21,12' and 10-1/2' respect-
ively. The hole locations are shown on the location map. All
holes were excavated by Hamann Construction Company of Eagle River,
Alaska, using aCase Backhoe with a 1/2 CY bucket. Direct
observations were made on soil strata and grab samples were taken
both during and after excavation.
Testhole placement was made on each of the smaller three tracts
to insure that soil conditions were as expected. There is more
than sufficient room on the tracts to locate water and wastewater
facilities.
5343 0 JUL
2 1974:
Creater Anchorage n ^ r'^
orough "�
Page 2
June 2, 1974
GEOLOGY. The Eagle River drainage area is located within the Chugach
Mountains that border Cook Inlet. These mountains are a complex
mixture of deformed and metamorphosed sedimentary and igneous
rocks deposited during the late Paleozoic and Mesozoic Eras.
Five major Pleistocine glacial advances along the consequent or
subsequent lacustrine and alluvial deposits greatly influenced the
present topography of the area.
The surficial geologic unit of the site appears to be part of
the Eagle River cut as it worked through the late Pleistocene
lateral moraine deposits. The till of this deposit is commonly
sandy and stoney with cobbles common. Broken rock and sand pre-
dominate but silt and rock dust are ever present. Cobbles and
rocks are rounded rather than angular.
SUBSURFACE CONDITIONS. The ground cover over the site generally
consists o a few inches of organic cover underlain with silty
sandy gravel with a trace of organics for another three feet. The
surficial deposits of silty gravels or sandy silty gravels are
inter-spersed with cobbles. The upper layer of material is of
medium density and the lower level of harder density as evidenced
by the effort of the backhoe during excavation. A consolidated
layer was encountered at three feet but was broken through at four
and 1/2 feet. Below this layer was 5-1/2 feet of well graded
.'gravel. The soils in general can be classified as CW/GM by
the Unified Soil Classification System. The hardpan appears to be
a GP soil.
The gravelly soils contain about 608 by weight gravel or cobbles
a4ith the remainder sand and/or silt.
Groundwater'was encountered only as a seeping flow just above the
hardpan layer and not as a saturated level. Since the water was
flowing through the soil and not ponding, it is felt that the
ground water level is much lower than the depth of the test holes.
There was no visible evidence of ponded water,rather the soil
appeared to be well drained, but compact.
CONCLUSION. Sufficient exploration has been accomplished on this
sma subdivision for the intended use with individual on-site
water and sewer facilities. Each tract has sufficient acreage
to allow for replacement soil absorption systems should the
initial system fail.
The soils are suitable with respect to foundation bearing capacity
within the range of conventionally applied bearing pressures for
Greater Anchorage A�4a Borough
Page 3
June 2, 1974
residential continuous concrete footings. If other than convent-
ional loads are anticipated, professional help may be required to
design the foundation. The steep'slopes must be considered in
any foundation system.
Please contact the undersigned if any expansion or clarification
of these data is necessary.
P_,%Z-jk]•ace, P.E.
L
LYNN ►. VL1t61Cf `'%I