ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Renewal
Date Issued: Jul 02, 2009
Expiration Date: Jul 02, 2010
Permit Number: SW090102
Legal Description: T12N R3W SEC 25 N2 NW4 NW4 NE4
Design Engineer: 0007 SPURKLAND ENGINEERING
Owner Name: MARTEN MARTENSEN
Owner Address: 5115 OLD SEWARD HWY
ANCHORAGE, AK 99503-
Parcel ID: 017-411-02
Site Address: NHN UPPER HUFFMAN
Lot Size: 217800 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
Ail construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and dosed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
A. Per the engineer-of-record: the house design will be elevated, allowing septic tank pump out to be within 100 feet
of the driveway. The location of the septic tank is only approved if the constructed house is elevated as proposed.
Date:
Date:, '~,~
ParcelI.D.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, A~aska 99507
www. muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
or'7"
Property owner(s) ~v~,nc-r~_.~ ~v%.~ ~.-r~.,,~ ~,-1~"~,--~
Mailingaddress ~"11~" o,/...c:, ~,.'~*..._.> .e..<...~ ~,~,.) .~
Site address -"r-t?..~ "~"~c3 '~c._ ~,F 1',3 7_.
Legal description (Sub'd, Block & Lot) 'T'I ~ ~ *'~-,".-5 c..~
Legal description (Township, Range & Section) '~-'l~. ~
LotSize ,?._l '7,
Day phone
Zip Code
~") ~ Zip Code
-.,,~...c- Z: ,>-- ~.
Sq. Ft.
Number of Bedrooms ~ /-7/
THIS APPLICATION IS FOR ([] all that apply):
Absorption Field
Septic Tank
Holding Tank
Priw
Private We,
Water Storage
THIS APPLICATION IS AN:
Initial ~
Upgrade
Renewal ~,
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush
Date of Payment:
Receipt Number:
(Rev. 11/05)
I
Waiver Fees:
Date of Payment:
Receipt Number.
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
{907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Jul 01, 2008
Expiration Date: Jul 01, 2009
Permit Number: SW080104
Legal Description: T12N R3W SEC 25 N2 NW4 NW4 NE4
Design Engineer: 0007 SPURKLAND ENGINEERING
Owner Name: MARTEN MARTENSEN
Owner Address: 10420 LONE TREE DRIVE
ANCHORAGE, AK 99516-
Parcel ID: 017-411-02
Site Address: NHN UPPER HUFFMAN
Lot Size: 217800 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] 'Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
A. Per the engineer-of-record: the house design will be elevated, allowing septic tank pump out to be within 100 feet
of the driveway. The location of the septic tank is only approved if the constructed house is elevated as proposed.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, Alaska 99507
www. muni.org/onsite
(907) 343-7904
ON-SITE SEVVER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
Property owner(s) MARTEN MARTENSEN
Mailing address 10420 LONE TREE DRIVE
Site address ~J~lk)I)ci~ ~()Pr--MAd
Legal description (Sub'd., Bilk & Lot)
Legal description ~ownship, Range & Se~ion) T12N R3W SEC 25 N2 NW4 NW4 NE4
Lot Size----~!7}, ~ Sq. Ft. ,umberof Bedr~ms 4
Day phone 227-3147
Zip Code 99516
Zip Code
THIS APPLICATION IS FOR ([~ all that apply): THIS APPLICATION IS AN:
Absorption Field [] Initial
Septic Tank [] Upgrade
Holding Tank [] Renewal
Privy []
Private Well []
Water Storage []
[]
[]
I certify that the above information is correct. I further certify that this application is being made for a
SinIle Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
PermitJRush Fees:
Date of Payment:
Receipt Number: (;~ ~c~'~'~'
(Rev, 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
Environmental Consulting and Design
I
Municipality of Anchorage
Development Services Department
Building Safety Division
On Site Water and Wastewater Program
4700 South Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519
Subject:
Permit SW 090102
T12N R3W SEC 25 N2 NW4 NW4 NE4
August 31, 2010
Ladies and Gentlemen:
To design the drain field for the above referenced property I used an application rate of 0.6 gal/sq.ft./day
based upon the percolation test conducted in conjunction with test hole//2 (22.6 min/in). For a four
bedroom residence this would require a minimum absorption area of 1000 sq.ft.
The previously approved design consists of two trenches 60 feet long with 5.5 feet of rock. This provides
an absorption area of 1320 sq.ft. While the soils logged in test holes #1 and #3 are generally similar to that
of test hole #2 some variation does exist. A percolation rate of 2 minutes per inch was observed in test hole
#1. The percolation test for test hole #3 was conducted in a shallow silt layer and was observed at 120
min/in. While a portion of the drain field absorption area may be in the silt layer, I believe an application
rate of 0.6 gal/sq.ft./day results in a conservative design that accounts for variability in the soils.
Below is a calculation of the absorption capacity of the proposed drain field based upon the soil
observation from the three test holes.
From Test hole #1 (approximately 50% of drain field area)
Effective depth of rock 5.5 feet
4.0 feet in soils rated at 1.2 gal./sq.fi./day
1.5 feet in soils unsuitable for stand septic system 0 gal./sq.ft./day
60 feet * 8 feet * 1.2gal/sq.ft./day + 60 feet * 3 feet * 0 gal./sq.ft./day = 576 gallons per day
From Test hole #2 (approximately 50 % of drain field area)
5.5 feet in soils rated at 0.6 gal./sq.ft./day
203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (907) 276-6013, SpurklandEng~gci.net
Environmental Consulting and Design
I
60 feet * 11 feet * 0.6 gal/sq.ft./day = 396 gallons per day
Total absorption Capacity = 972 gallons per day
If you have any questions or need additional information, please give me a call at 279-3916.
Sincerely,
Lars Spurkland, P.E.
Spurkland Engineering
I
203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (907) 276-6013, SpurklandEng~gci. net
Environmental Consulting and Design
I
SEPTIC SYSTEM DESIGN
TI2N R3W SEC 25 N2 NW4 NW4 NE4
Municipality of Anchorage
Development Services Department
On Site Water and Wastewater Program
4700 South Bmgaw Street
Anchorage, Alaska 99519
June 25, 2008
Subject:
Well & Septic Permit
TI2N R3W SEC 25 N2 NW4 NW4 NE4
Ladies and Gentlemen:
I am writing to request a permit for the construction ora new well and septic system for the above
referenced property. The proposed system will serve a 4-bedroom single-family residence.
System: A 1500 gallon STEP tank with a deep trench absorption field. The absorption field will
consist of 2 60 feet long trenches and contain 5.5 feet of sewer rock.
Soils: A test holes were excavated on September 5, 2007. See the attached soil logs. The soils
encountered were highly variable, but generally consisted of gravelly silt, silt, silty gravel, and
gravelly silty sand. Percolation rates varied between 120 min per inch in the silt oftest hole/13 and 2
minutes per inch in the silty sandy gravel in test hole #1. A conservative design was based on a
percolation rate of a highly silty area of the gravelly sand. Ground water was observed at 12' below
the ground surface in test hole #2 on June 4th, 2008. On June 24th all test holes were dry.
Surface Water: There are no surface waters within 100 feet ofeither the proposed septic system
area or the reserve site.
Topography: The topography of the area slopes to the west between 15%- 20 %. The drain field
will be installed parallel to the slope.
Waivers: No waivers am required.
203 West 15~h Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspurkland~gcl.net
[ ~ .. ~-.-..~ Environmental Consulting and Design
The installation of this septic system will not prevent wells and septic systems from being
installed on the adjacent lots. The proposed septic system will not change the general slope of
the area. Ponding and/or concentration of surface runoff will not result from this installation.
If you have any questions or concerns, please contact me at 279-3916.
Sincerely,
Lars Spurkland, P.E.
Civil Engineer
203 West 15~' Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspurkland~r~gci.net
Environmental Consulting and Design
I
SEPTIC SYSTEM DESIGN
TI2N IL;W SEC 25 N2 NW4 NW4 NE4
Municipality of Anchorage
Development Services Deparlment
On Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, Alaska 99519
June 23, 2008
We are submitting an application for the installation ora new well and septic system for the above referenced
property. The submittal consists of three (3) drawings showing the present improvements on the lot and the
adjoining properties. (sheet I/3), the proposed improvements oflhe lot, ofv, hich only the well and septic system is
subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and
· pcreolation tests ofapplicable testholes are also enclosed. The septic system deslgn is based on the following:
Groundwater at 12 ff.
Use deep trench with 5.5 feet effective depth
Soll Rating. From Testhole 6/4/08.
22.8 mtn/in = 0.6 gal'per sq.fVda
No. of Bedrooms 4
Required Area per Bedroom: 150/.6 --250 sq.ft.
Total area required: 250 x 4 = 1000 sqR
Bottom Rock At 7.5 feet
Top Rock At 2 feet
Rock Depth 5..5 feet
Total Trench Length ! 000/I I = 91 feet
SYSTEM CONFIGURATION
I$00 GAL. S.T.E.P. w/2 x 60 Fr TRENCIIES
TOTAL LENGTll 2 x 60 FT
TOTAL WIDTll 2 FT
TOTAL DEPTtl 7.0 let
ROCK DEPTII 5.5 FT
INSULATION 2 IN
COVER 2 FT (MIN)
203 West 15sh Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866)354-1597, Lspurkland~gci.net
uPP£;~ HUF£MAN £llAB
7'1~1 £$v SEC c~ ~
S8 NV4 NV4 N£4
N
1oo o
1oo c~oo ,9oo
SCALD 1' =
SPURKLAND ENGINEERING
205 W I$1'H. AVENUE
ANCN. Ar. 99S0~
(907) 279-Jgt~
Il7'12N £3g SEC25 ~Y2 Ng4 Ng4 NE4
I~ARI'EN I,(A£FENSEN
I S
EPTIC SYSI'EI~ DESIGN
DALE: JUNE 25, 2008
SHEEI': I/$ GRID: 2841
PE£MIF #SVOSOXXX PID # FI2N£3VS25N£Dl.d~g
I
No Veil ~ithln 180' oF Property Line to the North
UPPE£ HUFFMAN HI]AD
5,3' SECTION LINE EASEMENT
10' T&E EASEMENT
INSTAll 4-8£0£00kl SEPTIC SYSTEJt
1500 ~L
~O~ 2
TOTAL ~P~ 7
~K DEP~ 5.5
Reserve: Deep TrenchJ
Lengfh 60 Feel
~Tdlh 2 Feet
Total Depm 10 reel
Rock Depth 4.5 Feet
~ver 5.5 Feet
~ro?OSea
NOTES:
T12N P3V SEC 25
N2 NV4 NV4 NE4
SCALE, 1' = 50 FE
49th
~:PURKLAN[I
No.
SPURKLAND ENGINEERING
203 AY 15TH. AVENUE
ANCH. A~.
£$~[ SEC25 N2 NF~ N~ NEd
MARTEN MARTENSEN
SEPTIC SYSTEM DESIGN
DATE: JUNE 25, 2008
SHEET: 2/3 GRID: 2841
PE£MIT # PID # H2N£3VS25N2DI.d~9
N.T,S
7.0' Deep / ~:~. No. c~-t,~0o /~
5.5 ft o~ Septic Rock
~ffed~ve
Monigor
~' Cover'
Sg t Borrier
NO SCALE
5.5 ~ of Septic Rock'
Eff. d~e ~500 6AL SfEP TANK
· /
NO SCALE
SPURKLAND ENGINEERING I
203 W15th Ave
Anchorcge Ak 99501
TI2N R3~' S£5 N2 N~4 N~'4 N£4
MARTEN MARTEN$£N
SEPTIC SYSTEH DESIGN
DATE, ~ ~4, 2006'
SHEET~ 3/3 GRID~ ~6'41
PERMIT If S~¢0800XX PARCEL ID tf XX TI2NRJW$25N2D$.D~G
Performed For:.
Legal Description:
Municipality of Anchorage
Development Services Department
Suild[og Safety Di',';sion
On-Site Water and Wastewater Program
4700 South Sragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.munl.orglonsite
(907) 343-7904
Soils Log - Percolation Test
Slope
Date Pedo~ed:
Township, Range, Se~on:
Site Plan
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20.
WAS GROUND WATER
ENCOUNTERED?
IF YE S, AT VvHAT DEPTH?
Reading Date Gross Time Net Time Depth Io Water Net Drop
8" ,, ~:~0m I0 ~:n l~/8'' 5 Y~"
'' ,,
PERCOLATION RATE ~. (mJ~le~,¢~) PERC HOLE DIAMETER
TEST RUN BETWEEN '~ FT AND .l~ FT
PERFORMED IN ACCORDANCE ~,A/ITH ALL STATE AND MUNICIPAL ~-UIDELII~IE S IN EFFECT ON THIS DATE. DATE: ~1 Z ~IO~
Perlonmed For:.
Legal Desc~ption:
Development Se~ices Depa~ment I
Building Safe~ Dl~sion
On-S~e Water and Wastewater Pr~mm / . .~ ~.~. ~. F · .~. · t..
P.O. Box 196650 ~chomge, AK 99519~650
2-
3-
4-
5.
6-
7.
8-
9.
10.
11-
12.
13.
14.
15-
16-
17.
18-
19-
20.
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
Reading Date Gross Time Net Time Depth to Water Net {:~op
~'~" ~/V,~ ~ S:~ ~ i~/~"
PERCOLATION RATE '~I~ (rmmaesan~) PERC HOLE DtAMETER
TEST RUN BE'/%~VEEN [.~ FT AND ~"~ FT
PERFORMED SY: (.../)I[~ .~I')~,* ~ O4,~f.~ ' g (~j) I,~ CERTIFY TI-IAT THIS TES'I.[ WA~
PERFORMED IN ACCORDANCE VV1T~ ALL STATE AND MUNICIPAl. GUIDEliNES IN EFFECT ON THIS DATE. DATE:
· .
Munlc,pal,ty of Anchorage
Development Se~ices Depa~ment
Building Safe~ DMsion
On*Site Water and Wastewater Pr~m
~?00 soum B,~.~ st.
P.O. Box 196650 ~chomge, AK 99519~650
Soils Log- Percolation Test
Perfon~ed For:.
Legal De$c,'ipfion:
Slope Site Plan
~. S',\~
?.
17- ~'~"~
18-
19-
20-
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
IF YES. AT WHAT DEPTH?
Reading Date Gross TimeNet Time Depth to Water Net Drop
~,/~//~ 0 ~,, 4tzo Io"~ ,~"
Idl~" ,, .~ ~,:,, ,~'.so ~/,~" ~"
Io~l~" ,, ~ ~;~ 5~ 1o ~/~" ~1~"
IO~hu'' . 10 ~:. ~:~
PERCOLATION RATE
'lEST RUN BETWEEN
PERC HOLE DIAMETER
FT AND ~FT
PERFORMED IN ACCORDANCE V~ITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Elmore St,
P,O. Box 196650 Anchorage, AK 99519-6650
www.ci,anchorage .ak.us
(907) 343-7904
ON-SITE SEWER/VVELL SUBMITTAL COMMENT SHEET
To: Spurkland Enqlneerin.q
Legal description: T'I2N R3W SEC25 N2 NW4 NW4 NE4
~;;~Permit E]C.O.S.A. [-Ilnspection Report
The attached paperwork has been reviewed and is being returned for the following reasons:
~1. Soils Report Seal Date: The State of Alaska requires an engineer to "include the date each time
the registrant signs and seals a document". Please include the date on all signed and sealed
documents. (ref. Alaska Regulation 12 AAC 36.185 7d)
~. Septic Tank Pump Out Distance: The septic tank appears to be greater than 100 feet from the
driveway. Please substantiate the distance.
~. {~. Proposed Well Not Shown: Please show the proposed well on sheet 1/3.
(_4. Reserve Drainfield Design: The reserve drainfield design appears to be based on an assumed
percolation test value, Please substantiate.
Name of reviewer: Jay
Date: 6~30~2008
Please supply the necessary information and re-submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK