HomeMy WebLinkAboutSHANGRI-LA LT 19Shcxngri -La
Lot 19
#020 - 043 - 37
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 020-043-37
1. GENERAL INFORMATION:
Complete legal description SHANGRI-LA: LOT 19
Expiration Date: J —' � Z��Z
Location (site address) 6796 Shangri-La *Anchorage 99516
Current Property owner(s) Lisbeth Berge
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone 242-6125
Day phone-.
3. NUMBER OF BEDROOMS:
5
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 55 O Waiver Fee $
Date of Payment 1 a 15 b 21 Date of Payment
Receipt Number 0')N'39 G Receipt Number
COSA# 056.21 t 715 Waiver#
dl
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road Suite 101- Anchorage Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness Date: 12- /1412-/
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
6.D�IGNATURE
System #1 Approved for bedrooms
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
bedrooms, with the followi
#AECC884
\?NLITY
n/ r
o wqT 'SITE
lg�tipo(4& '
q Np
r P, v rr
Original Certificate Date: i z—[G - 7-1
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist Nitrate Advisory_
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
C0SA'%'-.;heck1ist
Legal Description: SHANGRI-LA; LOT 19
if more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
(IIm Well log is filed with Onsite (or attached)
Date drilled 8/21108
Total depth 301 ft
Cased to 47 fit
Sanitary seal is functioning correctly
�M Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 12/7/21
Static water level at beginning of test 26.1 ft
Comments
B, TANK DATA
Age of tank(s) 13 years
Tank type/material SEPT"" _
fvieasured operating fluid level in septic tank -
i�l Sandpipes/foundation cleanout per record drawing
Date of pumping SEE ATTACHED MAINTANENCE
D. ADSORPTION FIELD DATA
Which system tested (date installed) 8/20/08
W ALL standpipes present per record drawing
T otai measured depth from grade 6.25 ft (max)
.Measured depth to pipe invert from grade 3.83 ft (min)
❑ N/A — pressurized field
U Monitor tubes go to bottom of effective. If not, state
depth into effective
U Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced N/A gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 020-043-37
Structure served by this system
Well production at time of test 1.6 gpm
Water storage tank volume 300x3 gallons
Well disinfected for coliform test? ❑ Yes F1 1-1 No
[1foliform bacteria is Negative
Nitrate ' ' `j mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L Yrsenic less than MRL (ND)
Collected by GEG
Date of Sample 1213/21
C. LIFT STATION
❑ Required maintenance completed
Age of lift station 13 years
Lift station material STEEL
Comments,-
Adequacy
omments:
Adequacy test date 12/7121
Results [Z]Pass For 5 bedrooms
Fluid depth prior to test 0 in
Water added 792 gal
New depth 4 in
Elapsed time 40 min
Final fluid depth 0 in
Absorption rate 750+ gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date N/A
Q�1
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
❑ Yes
**501+
Community Sewer Manhole/Cleanout > 100'
❑ Yes
if No
ft
❑✓ Yes
if No ft
Neighboring Tank > 100' M Yes
if No
ft
Private Sewer/Septic Line > 25' ❑ Yes
if No ft
Absorption Field on Lot > 100'
p _ ❑Yes
if No
**50+
ft
Holding Tank > 100' Q Yes
if No ft
Neighboring Absorption Fields > 100'
Water Main > 10'
Q
Animal Containment > 50' ✓ Yes
if No ft
✓❑ Yes
if No
ft
Water Service Line > 10'
❑✓
Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' El Yes
if No
it
Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
❑ Yes
if No *5'+
ft
Surface Water > 100'
❑ Yes if No —501+
ft
Property Line > 5'
❑✓
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Absorption Field > 5'
❑✓
Yes
if No
fit
Private Wells > 100'
❑ Yes if No **50'+ ft
Water Main > 10'
Q
Yes
if. No
ft
Community Wells > 200'
❑ Yes if No ft
Water Service Line > 10'
❑✓
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
❑✓
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
❑
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Q
Yes
if No
ft
Private Wells > 100' **50+
_ ❑Yes if No ft
Water Service Line > 10'
❑✓
Yes
if No
ft
Community Wells > 200' Z Yes if No ft
Surface Water > 100'
❑
Yes
if No **501+
ft
F. ENGINEER'S COMMENTS
*MET CODE AT TIME OF INSTALL **AWWTS -SINGLE 2000 -GALLON ADVANTEX
TANK WAS INSTALLED & APPROVED BY MOA IN 2009.
G. ENGINEER'S CERTIFICATION ��`JOF
I certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance with pl , i H y i
MOA COSA guidelines in effect on this date. G • � j •
.
. .... ....:.. .
�% J ff;,-yless:
l� CF— 79 - 3
si. c°i G
�f
CCSA Checklist yellow sheet v V�/ p,o f e s stor°\ o
#AECC884
www.muni.org/onsite
Nitrate Advisory
Certificate of On -Site Systems Approval # OSC 211715
Subdivision: Shangri-la Lot 19
A water sample revealed a nitrate concentration of 6.84 milligrams per liter (mg/Q.
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Please see the attached "Nitrate Fact Sheet" for important
information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
From Northern Testing Laboratories, Inc.
Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate
is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.
SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of
ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the
oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners,
food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil.
TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years but is
associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of
young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood
stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry
oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the
concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered
from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.
TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home
water treatment systems such as softening, or iron filtration does not readily remove nitrate. The best
method for limiting nitrate in well water is source control. This can include avoiding overdosing of
fertilizer near the well and maintaining good separation distances between septic tank leach fields and
the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged
ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.
TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a
spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect
the activity of nitrate in water. This laboratory uses several different wet chemical methods approved
under the public water supply laboratory certification program. They also have test kits available, which
the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can
monitor the change in nitrate levels from their well. They recommend comparing the test kit results
against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend
using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER. TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this Day of Q-A- of 20 21 , by and between
Al j7 j a SEVCAI AIA 7149 herein the "OWNER," and the Municipality of
Rpm
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as Advo, te- J,'S rern
located at (legal description)
mAaepo 1-4 L-73
2. Maintenance, Repairs and Alterations.
(Owner is required to read, understand and initial each section)
- r Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
r 1. przn,
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
wner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2018)
Pagel of 3
*�, -
Owner acknowledges that the Municipality may request records of maintenance and
4 repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
�. Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
OWNER:
By: ignature) Date: l F— 9
THAJI;�-CV", (print name)
STATE OF- E*Sf ik M SSS Ot,L(1 )
) ss.
5� UOVis Co%.AA tq )
h
The foregoing instrument was acknowledged before me this`� day of 2(t
20_QL, by
NOTARY PUBLIC FOR 1'SSQ�
My Commission expires: j3�1 S
KRISTIN PONZAR
Notary Public - Notary Seal
STATE OF MISSOURI
St Louis County
My Commission Expires: May 19, 2025
Commission ##21273287
MUNICIPALITY:
BY \� (signature) Dater
(print name) Title:
(rev. 05/18/2018) Page 3 of 3
05/31/2021 14:12 8686770 APLUS PAGE 03
401 313
mew n IN sal on » men Room on I on
am RT i 5 INMO a M. R R 111 R BE 0
mm I IBM MEMO OEM man so a NONE
oil IN E
IN Y
®111
*hMwffLai.10 Field MaintenanceAnchorageTank
Annual InspE.ction 907-272-3543
Pmparty OwnadTtacWng i operator
Jahn & Lisboth Mui Dletto Larry Betts
SnoAddreia Come Phwe
6796 Shangri-La C t1e, Anchorage AK 99516 (907) 3487464
AX 649 10 R Cwmty 10 A Pod q RTU ANL I Data d L=1n=pctVon
AX -119343 SWO80063 406679 406672 RTU115202 03/24/2021
Retrieve O&M info
Daily flow
Recirc ratio
Tatter setttings; -S I )A
Perform Field Sampl'ng/Observations
MfU (15 xNTUs} p (6-9} DO (2-6)
1
51\
Odor of Sample
Typical WMust [I Earthy ❑Moldy
Non-typk:al asultN a ❑Cabbego ❑Davy
ofy film in pVU [ lyes to
o
Foam in tank [ I yes
Check Control Pano
Rociro Amps DischsMe Amps
Aurgble anti visual ala ns OK
Dias tone (t¢kemotry of y) Yes ❑ No
inspect/Ciean Pump system
Inspect Clean
Rl"rAJd .......... ..........
Sptice Box ......... .........
Float Cords ........ ..........
Floats ............. ..........
Pump............. ..........
Biotube° Fitter ...... ..........
131olube Pump Vault . ..........
Rocircitatino Sputter' We......
comments U r
Measure Sludge/Scum
Sludge
Scam
1stCompartmant
Current Q
V
Previotts
Cummt
Previous
2nd Compwtmont
Current
Previous
Current
Previous
Inspect/Clean AdvanTex Filter
Insp Ci n
Odor: Normal ❑ Pungent t.ateratslOdflcas
Biomat: Normal 0 Excesai a Pod Bottom
Bridging/Ponding None/Minor ❑ excessive intake vent
inspect(Clean Discharge Pump System
ins to CI n
Rlser/Ll Floats "
spl' Box // Pump
/jJrr � r
oat co �J li
Inspect/Service Other Systarn Components
In, t d�e,ra,n ins C
Disinfection Equipmom N..1 Dispersal f'es
Observations
AddHional Services Rendered
❑ Cleaned textile shoats? ❑ Replaced W items?
❑ Ropiaced/Used other Rams?
Parts Used; W o Waanaanty, S = Biftbla (l appropriata selection)
W a Item Number Description
Final/Safety Inspection
® RSV reinstalled (j LM halted on
dmwffold reconnected; flush valves closed Control Pattal reactivated
Sumpary/Recommendations
V System perf—Ing; no further action needod
i� Cast for service
❑ TVk meds pumping
C other?
signmtvre____.-- ^ 4 nate, Sf' 1-1 %--2„ 01
Fax completed foam to 1-866�384-7404