Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CROSS VIEW ESTATES BLK 2 LT 26
Cross View Estates Block 2 Lot 26 #015-221-84 O .~,~ Municipality of Anchorage ,,.~:.=: ,. Development Services Department ,.t::~:----::---'"" Building Safety Division ~ On-Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 ~ ~ www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW080144 PID Number: 015--221 --84 Nome: BRUIN BUILDERS Wastewater System: · New [] Upgrade Address: .3120 DENALI STREET SUITE 8 * ANCHORAGE, AK ABSORPTION FIELD Phone: No. of Bedrooms: (907) 562-5640 4 · Deep Trench r-I Shallow Trench [] Bed E3Mound []Other Soll RoUng: Total Depth from original grade: LEGAL DESCRIPTION 0.8 GPD/S,. rt. 9.8 Ft. Block: Lot: Subdivision: Depth to pipe bottom from orlglnol grade: Gravel depth beneath pipe: 2 26 CROSS VIEW ESTATES 2.46 Ft. 7.0 Township: Range: Section: Fill added above original grade: Gravel length: - - - SEE DWG. Ft. 54+ Gravel width: Number of lines: Distance between lines: WELL: · New [] Upgrade 2.5 Ft. 1 - Classification (Private. A,B,C): Total Depth: Cased To: Total absorption oreo: Pipe material: PRIVATE 201 rt. 201 rt. 756 so. Ft. D 3054/ F-810 Driller:. Dote Drilled: Static Water Level: Installer:. Dote installed: ALPINE DRILLING & ENT. 8/23/08 152 rt. SANDERS & SANDERS 8/20-21/08 'Yield: GPM Pump Set At: Casing Height Above Ground: 20 Ft. 2 Ft. TANK SEPARATION DISTANCES · Septic [] Holding [] S.T.E.P. [] Other* T____~...~To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: monk Field Station Tank Sewer Unes ANCHORAGE TANK 1250 Material: Number of compartments: Well 100'+ 100'+ --' -- 25'+ STEEL 2 - - - LIFT STATION Surface Water lOO'+ lOO'+ Lot Line 5'+ 10'+ _ _ _ sizelnaal,I .... Uon~ I "Pump on" level ab~' · · High water alarm at: Foundation 5'+ 10'+ - - - Curtain Drain = NONE KNOWN = Inspections performed b~ I I · -~ / ~emorks: FOUNDATION INSTALLED BUT NO HOUSE BENCH MARK LocaUon and Description: IS BUILT BOTTOM OF TANK © ST2 Assumed EleveUon:89.04 ENGINEER'S SEAL Inspections performed by: OEO, Ltd. Dates: 1st 8/20/2008 ~<~.,.~%.~ 2nd 8/20/2008 ~-~'Cv Development Services Department Approval / ~'"'""'" ~"~"'1 ..... : .... Conditional approval: Dot e :. ~,'; ::~;~y~r'n'~ %L:f/.i/CE 79 ..-' %% I. Reviewed and approved by: / '~--~////~ ,//'~~ Dote:/c~-~~// ,~%~¢,o ,es¢O?~O,~e " AS BUILT DRAWING %W080144 - 015-22 A B ~ ST1 74.88 10.73 [ ~ ST2 78.24 17.17 I ~ ~,i DBL1 79.91 21 .~8 ~ CROSS Vl~ ESTATES. ~ BLOCK 2, LOT 25 ~ DBL2 80.72 23.41 I xx C01 61 16 44.16 ~ x · N SC~E: N I MT1 63.92 39.50 I~ u~N~ D~INFIELD N~ 1" = C02 105.95 31.30 ~ x~ MT2 102.59 28.69 I~~ x~ ~ C02~TH~57 ~ / I I I ~ ~"~~~::::..~'..~':.;"x ,' k ~' / / ~~:.:.'.'.~.f;::.-:':::.'~'Zt~ ~ ,/ / //,,' '.k. GARNESS ~ENGINEERING GROUP, Ltd. ~_~..~_'_4~:~, PREPPED FOR: I PHONE NUMBER:mPAGE NUMBER: I '¢~'" i~",% ...... l ............ BRUIN BUILDERS I 562-3640 I 2 OF 3 i(~ ¢ '..Je~r~y~orness.: CROSS VIEW ESTATES, LOT 26, BLOCK 2 K D ~ ~q~hfo, "¢.~'~1/~.~:-'"'.~J/ AS-BUILT BRAWlNG 10/7/2009 ~%%~ (Rev. 01/05) AS BUILT DRAWING ~W080144 - 015-221 -84 ST1 TOP OF TANK --x r::::l AT INLET = 9.3.96 ~~'1 I NEW 1250 GALLON SEPTIC TANK FINAL GRADE = 98.27-98.61 ST2 V~lNVERT OF BUNG AT OUTLET = 93.12 TH#57 ORIGINAL = 94.25 MT CO GRADE = TH#1 95.98-96.98 FABRIC Of PIPE = 91.45 BOTTOM OF TRENCH = 84.45 RELATIVE ELEVATION Of RELATIVE ELEVATION OF BOTTOM OF TEST HOLE = BOTTOM OF TEST HOLE = 78.25 (DRY) 77.75~ GARNE$S ENGINEERING GROUP, Ltd. '" CONSULTANTS & GENERAL CONTRACTORS 3701 F... TUDOR ROAD. SUllE 101 * ANCHORAGe, AK 99507 * PHONE (907)~,~7-6179 * FAX (907)~158-3246 * WEBsrlE: ww'e',g<:lmeasenglll~erlng.com PREPARED for: IPHONE NUMBER: I PAGE NUMBER: BRUIN BUILDERS I 562-,5640 I 5 OF ,'3 LEGAL DESCRIPTION: CROSS VIEW ESTATES, LOT 26, BLOCK 2 TYPE OF WORK: 4!9~ ".~§~ DRAWN BY: ¢--7953 .."_~/ K.D.M. ~ ] '" PROfiLE ~S-~U~LT 9/2/200~ (Rev. 01/05) OH :Alpin~ Drillin9 FAX NO, ;907 345 8202 F~b, 03 2009 04:12P~ Pi ALPINE DRILLING & ENTERPRISES Permit Number: #S.W060144 Date of Issue: 7-28-08 Date Started: 8-22-0_._____[8 Date Completed: 8-23-08 Parcel Identification Number: 015-221-84 Is well located at approved permit location? [~ Yes D No Legal Description: Property Owner Name & Address: Borehole Data: Soil Type, Thickness & Water Strata stick-up silt gravelly silt silty sandy grave/ silty gravel gravelly cobbly silt silty gravel. silt silty gravel silty water sand & gravel water sand & gravel Cross View Est BIk 2 Lot 26 Bruin B'uildersl Inc. 3120 Denali St Suite 8 Anchora~le, Alaska 99503 Depth (ft) Method of Drilling [] air rotary From To 0 2 2 8 8 52 52 56 56 84 84 96 96 101 101 152 152 181 181 198 198 201 [] cable tool Casing type: steel Wall Thickness: .025 inches Diameter: _6 inches Depth: 201 feet Liner Type: ~ Diameter: ~ inches Depth: ~ Casing stickup above ground: _2 feet 'feet Static water level (from ground level): 152 feet Pumping level: 200 feet after _2 hours pumping 2_Q0 gpm Recovery Rate: 20 gpm Method of Testing: air lift Well Intake Opening Type: [] Open End [] Open Hole [~ Screened Start ~ feet Stopped ~ [] Perforations Start ~ feet Stopped, Grout Type: bentonite granules Volume: 2_ Depth: Start _0 feet Stopped ? feet Pump: Intake Depth __ feet Pump size __ hp Brand Name Well Disinfected Upon Completion? [~ Yes [~] No Method of Disinfection: chlorine tablets Alpine Drilling & Enterprises P.O. Box ff0496 Anchorage, AK 99511-0496 Comments: Well Driller: Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property owner or the well driller shall provide a well log tO the Development Services Department within 60 days of completion0 Pump InstalIat]o~ Log V~eLI DrflIing Permit Number: Date of Lssue: Parcel Identification Number: Legal Desc2ption 19--72- L-Z 6 p~p ~mke De~th Bebw Top ofWe~ Cas~g: ~ ~:' feet Pump ~an~ac~rer's Name: :,~:--~ ': '' Pump Size hp lPifless _,&dapter Burial Depth: ,, feet t Property Owner Name l/ Atl:ention: lie pump mstzLIer shall provide a purmp in~talIation log to the DSB within 30 iaB of pu~np mmtailmriom. GA.RN-ESS .ENOINEER.I~G GROUP, Ltd.~ ~,~ ~c..~,o.. c.o~s ~,~ ~ s~.~,o.; ~o~ ~, ~oc. ~ . (f;et~ ~OROANIOS ~O'b LO0 *H¢1 2~ BLOAM SOIL CLASSIFJ:~TI:~S It :11111 .L.:::: ;$ ~, &' e , N q lllll SITE PLA 7 DEPTH TO DATE / IIIIII ......... .,~ CLOCK NET TIME I WATER LEVEL NET DROP 11~ ~J[~ll ua.~ xuau,,,u TINE (NINUTES) READING (INCH~ I PERCOLATION RATE - (MIN./INCH) PERC. HOLE DIA. - (INCHES) ~9 ~/ ~ TEST RUN BETWEEN - FT. AND - FT. 20 ~~ A FOUR HOUR PRESOAK WAS PERFORMED: ~ YES ~ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: - COMMENTS: PERFORMED BY GEG, L~d. I, dEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER DRY 8/20/2008 MUNICIPALITY OF ANCHORAGE Development Services Department On-Silo Waler & Wastewaler Program 4700 South Bragaw Streel P,O. Box lg6650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jul 28, 2008 Expiration Date: Jul 28, 2009 Permit Number: SW080144 Legal Description: CROSS VIEW ESTATES BLOCK 2 LOT 26 Design Engineer: 0855 GARNESS ENGINEERING GROU~ Owner Name: BRUIN BUILDERS, INC. Owner Address: 3120 DENALI STREET SUITE 8 ANCHORAGE, AK 99503- Parcel ID: 015-221-84 Site Address: NHN HERITAGE HEIGHTS DRIVE Lot Size: 43464 SQ. FT, Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A. The confirmation test hole indicated on the plans shall be excavated prior to construction. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.a nchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR .A SINGLE FAHILY DWELLING Parcel I.D. Property owner(s) ~F{UIN BUILDERS. INC. Day phone 562-3640 Mailing address ,3120 DENALI STREET. SUITE 8. ANCHORAGE. AK 99503 Legal description (Sub'd, Block & Lot ) CROSS V1EW ESTATES SUBDIVISION: LOT 26. BLOCK 2 Legal description (Township, Section & Range) Lot Size q 51 ~ (-~/''~ Sq. Ft. N/^ Number of Bedrooms 4 THIS APPLICATION IS FOR ( ~;~all that apply): THIS APPLICATION IS AN: Absorption Field [] Initial [] Septic Tank [] Upgrade [] Holding Tank ~ Renewal [] Pdvy U Pdvate Well [] Water Storage [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/RushFees: ~O 4 l"/-5 Date of Payment: ""~/~- ~ ) o~ Receipt Number: ~'~ ~, 5~ D (~. ~ 1/o~) Waiver Fees: Date of Payment: Receipt Number:. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS "~*'"'"-" July 22, 2008 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Bmgaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Well and Septic System for Cross View Estates; Lot 26, Block 2, To whom it may concern: The proposed 4 bedroom house will be served by a private well and septic system. A test hole was excavated on the property for the subdivision. We are proposing that a confirmation test hole be excavated prior to construction to confirm soil conditions and to encompass the prima~ and alternate site. We are proposing to that a new 1250 gallon septic tank and a dual deep trench type drainfields be installed. The drainfield will be designed around the 30 foot radii of the test holes. Comments regarding the design are summarized as follows: I. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. The percolation rate was found to be <1 minute/inch. However, the insitu sandy soils, which is a SM to ML material, will act as a sand filter. No sand filter should be required. This will be conf'u'med with the excavation of the additional test hole. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface wate~ within 100 feet ofthe proposed septic system. 4. TOPOGRAPllY: As can be seen on the attached design drawing, the average topography below the drainfield is a 10-15 percent slope running approximately east to west. In short, there are no slope conceras. We are unaware/~f any adverse impacts this installation would have on adjacent wells or septic systems. I f you have any ~u~stions," '~'~" please contact us at 337-6179. Thank you for your assistance. II NOTE~ Ittached is a site plan drawing, a design drawing, and one soil log, which are all part of thc design package for this septic ~vstem. (Contact G.£.G. £td. for ?page construction spec~fication letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Wcbsite: www.gamessengineering.com I CRO~S V1E'W ESTATES. CROSS ~ ~A~S. I I B~K 2, ~T 20 ~ I III .... T- ~ I c~ms ~ ~*~. I II // ~. ~ * * I BL~K 2, LOT 24 ~ I CROSS ~ ~A~S, I 8L~K 2, LOT lg i ~ , t ~ Il ~----~ ~ ', ', ~ ~1~- / i I ~, ~ / . ,, ,, , , : ~ -/ II I ~,~t~ I . ~T~ s~l I I ~ O~S~N, P~ ~ or ~) I I ~ ~L~ ~. LOT ~S J:--~4-. x XS r~"' ~ ~ I ~i~ ~L k~~----. ', ~'// /-~ 5,,~.~:---. ', I / --1' - ~' /I/1~~- ~ .... "~t . ~. ,, BRUIN fiUILDERS I 522-62~0 I 1 OF 2' ~ ~"? ~*~' es~.:, ~ ~,,~o. ~w, .,: ~,"t 2F-~?L..'".~/ CROSS VIEW ESTATES. LOT 26, BLOCK 2 J.LM. SITE P~N FOR PROPOSED WELL · SEPTIC SYSTEM 7/22/2008~%~/~ ~ i , , GEG. Ll.d. HAS A 7 PAGE SP£¢IFICATION NOTE: TILtE CONTRACTOR SHALL LL'TrER THAT PERTAINS TO ~HIS DESIGN. NUMBER Or eEDROOUS: 4, TO OBTAIN A COPY OF THE L[Ht:R J'~V~ THE CONFIRMATION TEST GN. LONS PER DAY (GPO): 600 CONTACT GIG. BY PROCEEDING FORWARD HOLE EXCAVATED PRIOR TO ANY P£RCOI.ATION R~T~/$: e<l MIN.INCH ~ TH~S ~N~ON. TH[ ~¢mNE£R. CONSTRUCTION. THE CONTRACTOR · ~NS~TU SANDY ~OILS W1LL ACT AS SAND F1LT[R WELL DRILLER, CONTRACTOR AND PROPOSED APPt. JC~TION RAT[: 0.8 PROPERTY O~ER .~CR£E ~T ~ SHALL HAVE THE NORTH LOT UNE UINlUUU D~NRD. D SO.FT.: 750 NAVE READ THESE SPEClRCA'~ONS AND AND THE 20 FOOT GAS EASEMENT AGREE TO ACCEPT THE TERMS AND FLAGGED BY A REGISTERED LAND CONDITIONS OUTLINED. DRAINFIELD DESIGN: SURVEYOR PRIOR TO ANY ~)uuu Do'm: 10 FEET I,u, xlu~ CONSTRUCTION. WIDTH: 2.5 FELT r.-ALTERNATE SITE. ~ILL REOUIRE L~NGTH: 54 Ir[ET LONG (20 27 FEET LONG EACH) / ADVANCED WASTEWAT[R b-YST[M. \\ [F'F[C/N~: 7 FEET / ~PROPOSED DRAINFi~:LDS \ __1~ , ~ ~¢rj,I Ya'll I ~ i I u dp t]Do [ICG r----' I~- I I / ----~-1 I I LLJ ! pROPOSED - /,.~ ~ s~.-//-4~" o _1 ?_o.._o_s~_ . \ j ~ ! PROPOSED 1250 G.~.LON/ ~ / ~o~ ~ ~ sEP.C TAN~~ / / ~ ~.':~ _1 / I ~:.~ ....... x.----% -' ' t ~ '"'~ -/", : J..'~. · ...~"~ .... . // / ' I ~-, ~i.'.'t' ///// :o. ' ' GARNESS ENGINEERING GROUP, Ltd. //q~:" ~g ~J~ ".?.' ~ PREPARED FOR PHONE NUMBER PAGE NUUBER: ~ ',~'~." BRU~N BUILDERS. INC. J SS~-~S40 ~ Or ~ k~e"-.~ 1"~?""~'', ~,/ CROSS VIEW ESTATES S/D; LOT 26. BLOCK 2 J.L.M. N~h~% '~1~.~.'~,~/ DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM 7/22/2008 GARNESS ENGII~TEERING GROUP, Ltd. ~c~.."~?_ ~' '"-..~?{'~ CONSULTANTS & GENER~AL CONTR,A*'TORS ~ ~.?__ ~so~c coo - ~.coc~x~o. ~sx~ ~~ L...].~ ~....~ LEC~ DESCRIPTION' CROSS ~ [~A~S SUBD~SION; LOT 26, BLOCK 2 ' ' ' DEPTH ~ ('~o"~'cs ITH~57/PTS~5121 .... .. GP ~ NL GC OL . ,, SW HH SP CH SH OH sc SEE A~ACHED SITE P~N DEPTH TO DATE GROUNDWATER DRY 8/3~/2005 9~[ll]lsu/ML DRY 9/19/2005 DRY 7/17/2008 10 1~ DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) 2 - 4 O" 6' 13 5 - - 6- _ 4 - 4 O" 6' 14 5 - _ 6- _ 6 - 4 O' 6' 15 16 17 18 19 PERCOLATION RATE *<1 (HiN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5 FT. ~D, 6 FT. 20 A FO~ HO~ PRESOAK WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY:, JODY MAUS PERCOLATION TEST PERFORHED BY: ~EB CALL COHHENTS: · INSITU SIL~ ~D SOI~ WILL ACT ~ ~D RLTER. RECOMMEND A 0.8 ~PLI~TION ~TE. PERFORMED BY GEG, Ltd, I, JEFFR~ A. GARNESS. CERTI~ T~T THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Municipality of Anchorage DevelOpment Services Department CERTIFICATE FOR A Parcel I.D. 015-221-84- 1. GENERAL INFORMATION Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEMS SINGLE FAHILY APPROVAL DWELLING COSA# C).iDP-_~ ~\ ~ Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency CROSS VIEW ESTATES; BLOCK 2, LOT 26 5082 HERITAGE HEIGHTS DRIVE *ANCHORAGE, AK BRUIN BUILDERS Day phone 47~-3 SYDNEY PARK CIRCLE *ANCHORAGE, AK 99516 562-3640 Day phone Mailing address Real Estate Agent Day phone Mailing address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: T~ dF WATER SUISC*~Y: ~'; " . .': , :., ~, . ¢., .. · "' Indivdua Well ~ . -~ - l,ndi~iCbal ,.V~ater..S,toE~ge ComCn'drrity ClaSS " Well 'P. ttbliC, water S, .y.stem ', 4 TYPE OF WASTEWATER DISPOSAL: · Individual On-site [] [] Individual Holding tank [] [] Community On-site [] [] Public Sewer El' The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address 3701 E. TUDOR ROAD, SUITE 101'* ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore.not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for ~( bedrooms. Disapproved. Conditional approval for Attachments: COSA Checklist Septic System Advisory bedrOoms, with the following stipulatione~.'~ ~..~ .~'~ ON-SITE ~ATER AND - . WASTEWATER .... Arsenic Advisory Maintenance Agreements Well Flow Advisory Nitrate Advisory (Rev. 11/05) Supplemental Engineer's Report Other Original Certificate Date: / [ ~/'.~-/~/ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Legal Description: CROSS VIEW ESTATES; BLOCK 2, LOT 26 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 8/25/08 Sanitary seal (Y/N) YES Total depth 201 ft. Cased to 201 .ft. FROM WELL LOG Date of test 8/23/08 Static water level 1 52 ft. Well ProdUction 20 g.p.m. WATER SAMPLE RESULTS: Coliform O cdlonies/100 mi. Arsenic: f~) B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1250 gal. Number of Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) __ Date of pumping : Pumper ,~ ;! !~i ',,' C. ABSORPTION FIELD DATA Date installed 8/20-21/08 Length 54+ ft. Total depth * 12.75 ft. Date of adequacy test Fluid depth in absorption field before test 0 in. Elapsed Time: 1098 min. Final fluid depth 2 Any rejuvenation treatment (past 12 mo.) (Y/N & type) Nitrate~ '3~,~ mg./L. Date of sample: 11/1/11 CHECKLIST Parcel ID: 015-221-84 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 11/1/11 155 ff. 8.16 g.p.m. YES Collected by: GEG, Ltd. YES 24 in. Date installed 8/20-21/08 Cleanouts (Y/N) YES NO High water alarm (Y/N) occ P -o [*BELOW EXISTING GRADEI Soil rating (g.p.d./ft~or~ 0.8 Width 2.5 ff. Eft. absorption area 756 ft2 Monitoring tube YES 11/1/11 Results (Pass/Fail) PASS Water added 1250gal. in. Absorption rate >= NONE KNOWN System type TRENCH Gravel below pipe 7.0 .ft. Depression over field NO For 4 bedrooms. New depth 22 in. 600+ g.p.d. If yes, give date - D. LIFT STATION Date installed "Pump on" level at__in. Datum ._-------- E. SEPARATION DISTANCES' SEPARATION DISTANCES FROM WELL ON LOT TO: F= Size in gallons Manhole/Access ~ s "Pump off" level et~-----in~"~-. High water alarm level at Cycles tested Meets alarm & circuit requirements? 100'+ Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas. 50'+ in. On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N//A 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5' + Property line 5' + Water main N/A Water service line. 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field 5' + Surface water. 100'+ Property line 10'+ Building foundation. 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ COMMENTS Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance, with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date I ' ] ~ /11 COSA Fee $ Date of Payment Receipt Number (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number. 10/06/2011 03:19 ~07~45074~ AWPS~ INC. PAG£ 03/05 SGS Ref.~ 1 l t 0556001 Ctie,t Name Anchorage Well & Pump Service Printed DategTime 02/24/2011 13:53 Project 1Name/# 5082 Bainbridge Colle¢tccl Date/Time 02/17/20] I 10:25 Client Sample ID Kitchen Sink Recelved Date/Time 02/17/20I ! 1.0:50 Matrix DrJrtking Water Technical Director SterJhen C, Ede Sample Remarks: All~wable ?r~p Analysis Parameter R.¢su[ts LOQ Unit* Method Container ID [ imJts Date Date [nit Metal~ b7 ICP/MS Arsenic ND 5,00 ug/L EP200.8 C (<1() 02/2~/I 1 02/23/1 ] NRB Wa~ D, ¢pa~-tment Total Nitrate/Ni!irire-N 1,20 O. lr0O rng/L $M2-0 4500NO3-F B (<1(7 02/19/11 AYC Mierobiolog~ Laboratory [3. Coli Ne~Zative 1 100mL $M20 9223B A 02/17/11 DLC Total Coliform Ne~ativ~ 1 100nlL SMi20 9223B A 02/17/1.1 DLC C 14.0' 15..5' 10.0' 3,0' 32.0' ~'~, CONC. WALK CX 10' T. & £. ESMT. N 00'08'17"E 224.71' 26.2' 26.1'