MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division F f4 [(frA
On -Site Water & Wastewater Program M
ON-SITE SEWERM/ELL PERMIT APPLICATION MAY 18 2015
Gretchen Stuller
Parcel I.D. 0 -5 /— 13 1-/ —/ /
Property owner(s) _ �1��/ l0.✓77Zi7�.f/�J /� Day phone �5r- y077
Mailing address �?�•.� h
Siteaddress 11093Y fah
Legal description (Sub'd., Block & Lot) /,_���1/�L� (�//� GDTS
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms_
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(S all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF)
(w/wo ADU)
Septic Tank
Upgrade KDuplex
(D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
or
Permit/Rush Fees: 4,Q/5 --
Date of Payment: 5 I1RIA!5
Receipt Number: 09 a 1w
yment: �wQ%y�OtS YhOV edJJ
Number. ` 'Qv'�Na.
40.
MP15-J L2,?
d
S'wogoly� �: le .
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SW080146 PID Number: 015-134-11 ✓❑ New ❑ Upgrade
Name:
ABSORPTION FIELD
MM&M Contracting
❑ Deep Trench .'❑ Shallow Trench ❑ Bed ❑ Mound
Address
P.O. Box 670495 Chugiak, AK 99567
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
688-1236
4
1.2 GPD/SF
5 FL
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3 Ft.
Gravel depth beneath pipe
2Ft.
Subdivision - Block Lot
Fill added above original grade
4-5 Ft"
Gravel length
70 Ft.
Denali Vue 5
Township Range Section
Gravel width
5Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
- Septic Absorption Holding Sewer
Total absorption area
Number of trenches
Dist. between trenches
Lift Station
Tank Field Tank Line
50D Ft z
One
Ft.
From
Well
>100,
>100'
>100'
>75'
>25'
TANK El Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,25DGaI.
Surface Water
>100'
>100'
>100'
>100'
Material
- Steel
Number of compartments
Two
Lot Line
>5'
>10'
>5'
>5'
NA
Foundation
>5'
8'**
>5'
>5'
LIFT STATION
Manufacturer
Capacity
Gal"
Curtain Drain
None
Noted
Pump on level at
Pump off level at
High water alarm at
Remarks House was only recently constructed on the lot.
in.
in.
in.
**See Waiver. -
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL Housetotank D3034 Tankto D3034
drainfieid
Installer
MM&M Contracting
Draingeld F810 co/MT D3034
Inspector
BENCH MARK (Assumed elevation) 100.Oft
A.Harala
Inspection 1"7121/08 m 7/21/08 -
Location and description
dates: 2
Garage Slab.
3" 5/9/15 4'"
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
�F A 111
''%.
F,....... <0
Date
Conditional Approval:
a
• .•
j..................................
go %MICHAEL E. ANDERSON : �'
81
mw
Approved4Date uT-/ $
".�f ;F 5S1``p���w
.;
Inspection Report_1-1-12.dQc '
Permit Number: SWO80146
i I
I �
I I I
I I
I I I
I I
I I I
I I
I I
I I
I I I
I I
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
LOT 6
DRIVEWAY ESMT. FOR THE
BENEFIT OF LOT 5
(2015-000478-0)
10' T. & E. ESMT.
IN 87'00'45"E
I
I
LEGEND 3s\
4`?E
MT —
p
CO —
A B
TH —
S1
44.6' 49.4'
n
Ln
S2
52.4' 43.5
Mi
93.5' 11.5'
C4
26.0' 65.2'
C5
94.7' 12.3'
N
N
O
Z
LEGEND 3s\
4`?E
MT —
Monitor Tube
CO —
Clean Out
TH —
Test Hole
FCO
— Foundation Clean Out
2CO
— Double Clean Out
®TH2
S2
froom
ge
Nome
Page 2 of 3
PID No.: 051-134-11
I
� II\ I
\ II\ I
252.50'
LOT 5
PLOT N0. 2005-152
DENALI VUE SUBDIVISION
I
I
I
11
LOT 5 20' T. & E.
54.671 S.F. 3' SECTION LINE
S 89'56'58"E 144.07'
20' WATERLINE ESMT.
(2013-032440-0) \ \
PLAN AS -BUILT\\
SCALE V = 40'
5
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: SWO80146 PID No. 051-134-11
00.9
N U UN
Existing Finishetl
GmuntlWG1d�7
4.34.1
v 100.9 T 100.8 1,
PROFILE AS -BUILT -
No Scale
93.1
May 14, 2015
Municipality of Anchorage
Development Services Department
Building Safety Division
4700 Bragaw Street
Anchorage, AK 99507
Attention: Plan Review Engineer
On -Site Water and Wastewater
Subject: Lot 5, Denali Vue Subdivision
Septic Tank to Absorption Trench Waiver
Dear On Site Engineer:
The septic tank on Lot 5, Denali Vue Subdivision was constructed 2' from the edge of the
absorption trench. The trench was place first and the tank after the foundation was constructed.
The outlet of the tank is l' above the absorption trench. The trench has only a 2' effective depth.
The soils in the area are well graded gravel (GW) and little migration of sediment is expected.
The tank was constructed on well compacted ground and remains level after 7 years. The
placement of the septic tank at this location will have no adverse affect on the absorption trench.
We hereby request a waiver be issued allowing the septic tank to be 2' from the absorption
trench.
Sincerely,
OF gC
Michael E. Anderson, P.E. GJ�P•' 4 SQA
AW�a• 49TH ;
Attachments '~ t• yl �• yrj
IASL E. ANDERSON
CE -4381
RROFESSO
1,4% ��
May 14, 2015
Municipality of Anchorage
Development Services Department
Building Safety Division
4700 Bragaw Street
Anchorage, AK 99507
Attention: Plan Review Engineer
On -Site Water and Wastewater
Subject: Lot 5, Denali Vue Subdivision
Foundation to Absorption Trench Waiver
Dear On Site Engineer:
The house on Lot 5 Denali Vue Subdivsion was only recently constructed. The septic system
was constructed in 2008. The foundation wall was constructed 8' to 9' from the edge of the
absorption trench. The attached drawing illustrates the absorption trench and its location in
relation to the house foundation. The influence line of the footing and foundation when projected
down at a 1:1 slope does not encroach into the absorption trench. It is unlikely that the location
of the trench will have any influence on the foundation. We hereby request a waiver be issued
allowing the absorption trench to be 8' from the foundation wall.
Sincerely, ® �I
Michael E. Anderson, P.E.
Attachments
+A,. MICHAEL E. ANDERSON
J'. CE -4381 .•2� ,
�I��pROfESSlO�a���
DENALI VUE SUBDIVISION
LOT 5
FOUNDATION TO ABSORPTION
TRENCH WAIVER
SCALE 1" = 3'
Municipality of: Anchorage
Ment S
P
�4
a n
v
Q ry
N
epfw ment
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSVI51037 COSA#: OSC151220 Permit#: SWO680146
PID#i 051-134-11
Legal Description Denall Vue
Engineer. Anderson Engineering
Applicant: MMBM Contracting
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the foundation has been approved. The approved separation distance is 8.0 feet.
Also approved 2 feet separation distance tank to absorption field.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from:this department.
F The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver:
Notarized..letter(s) of non -objection have been received from the .owner(s) of the affected
adjacent property.
Adjacent properties are not affected by this waiver.
Waiver is Granted:`' XI. Waiver is not Granted:
Date:�J �'T 1 .� Approved by:
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program, 4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507 Page of
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW080146 PID Number: �t134-11
Name:
MM&M Contracting, Inc.
Wastewater System: ✓❑ New ❑ Upgrade
Address:
P.O. Box 670495 Chugiak, AK 99567
ABSORPTION FIELD
Phone. Number of Bedrooms:
688-1236 4
[1 Deep Trench rd Shallow Trench ❑Bed ❑Mound ❑ Other:
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grade.
1.2 GPD/Ft2
5 Ft.
Block, Lot: 5 Subdivision:
Denali Vue
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
3
Ft.
4 Ft.
Township. Range: Section:
Fill added above original grade:
Gravel Length:
2 Ft.
70 Ft.
Well: ❑ New ❑ Upgrade
Gravel width:
Number of lines:
Distance between lines.
5 Ft.
1
Ft.
Classification (Private, A, B, C):
Total Depth:
Cased to:
Total absorption area:
Pipe Matenal:
Class C
Ft
Ft
500 Ft2
ASTM D3034 PVC
Driller
Date Drilled:
Static Water Level:
Installer.
Date Installed:
Ft.
MM&M Contracting
7/20-22/2008
Yield,
Pump Set at:
Casing Height Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION DISTANCES
® Septic ❑ Holding ❑ S.T.E.P. ❑ Other:
To
Septic
Absorption
Lift
Holding
ublic/Private
Manufacturer:
Capacity:
From
Tank
Field
Station
Tank
Sewer Line
Anchorage Tank
1,250 Gal.
Well
>150'
>150'
N/A
N/A
>25'
Material:
Steel
Number of Compartments:
Two (2)
Surface Water
>100'
>100'
>100'
N/A
LIFT STATION
Size:
Manufacturer:
Lot Line
>5'
>10'
>5'
N/A
Gal.
"Pump on" level at:
"Pump off' level at:
High water alarm at
Foundation
>5'
>10'
>5'
N/A
in.
in.
in.
Curtain DrainNone
Noted
Pump Make & Model
Electrical Inspections performed by
Remarks
House Not In Place. No As Built Survey Completed.
BENCH MARK
Location and Description:
Locations are Not Accurate. Extensive Grading Required
Lowest Level Concrete Slab.
Assumed Elevation:
Over Entire Project. Elevations Will Change.
100.0
Ft.
�p
Inspections performed by: M. Anderson Dates: 1st 7/21/2008
�.,�°�` ©F
o+
2nd 7/22/2008
��.•�v
Development Services Department Approval
0 '
495.8 '
:d
00
Conditional Approval Date: 10
*;•'
y� J�
�s+p• .q..+• ewr+p.++s+e•
-*MICHAL1 I: AME"0N.: ,QT
Reviewed and approved by: ." y C `Date:
P �A+
(Rev. (AA)6)
IN
Permit Number: SW080146
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
DENALI VUE SUBDIVISION
LOT 5
54,671 S.F.
THORNTON DRIVE
S 89'56'58"E 241.03'
Pages
PID No.: 051-134-11
------------------------------------------ '
T 3' Section °0
Line Easement o
0
20' T. & E. Easement ---
—---------------- -------------------------------
E
m
0
w
W
i�
y
�rOde Rre,,k
Grode 3reok
A 1 8
S1 1 10.0' 29.2'
C4 1 15.4' 39.0-
M1 1 27.0' 42.2'
S 89.56'58'E 153.50'
®TH2
PLAN AS -BUILT
SCALE 1' = 40'
Drawing Prepared Without a Surveyed As Built.
Locations Not Exact. Driveway Not Complete.
N
00
Four Bedroom 6
Home a'
Ln
Foundation Only
(Exact Location Unknown) r,
® 4�
S1 v
Alternate Site
TH1
C5
49th
................................................
MICHAEL E. ANDERSON
A ��:, NO, CE -4381
•••��� pR�FESSI�Pi�••:
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW080146
/-98.4
U) UU
Page 3of3
PID No. 051-134-11
Existing /linished
Ground Ground
1,250 Gallon
Septic Tank
Y93.55 93.4
NOTE: House and Driveway Not Complete. Extensive Grading to be Completed Prior
to Project Completion. Elevations Shown Will Change.
93.1
U
97.3
Finished Grade
— —_
Existing Grade
84.0
No Groundwater
z
E—
i:Z
Drainfield Rock
70' (Trench Length)
91.1
LO
ii U
n 96.8 n
NOTE: House and Driveway Not Complete. Extensive Grading to be Completed Prior
to Project Completion. Elevations Shown Will Change.
PROFILE AS -BUILT -
No Scale
93.1
.•�P( 1�4
49�. th�...'�s%.
� =, MICHAEL E, ANDERSON•��,4
• �uu
✓��: No. CE -4381 1
►�.•� pR� ..••
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Jul 28, 2008
Expiration Date: Jul 28, 2009
Permit Number: SW080146 Parcel ID: 051-134-11
Legal Description: DENALI VUE LOT 5
Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 19639 THORNTON STREET
Owner Name: MMBM CONTRACTING, INC. Lot Size: 54671 SQ. FT.
Owner Address: PO BOX 670495 Total Bedrooms: 4 Permit Bedrooms: 4
CHUGIAK , AK 99567 -
This permit is for the construction of:
❑d Disposal Field g Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Date:
D
v
Issued By: ��1t'.1�� �%I,iI 7� Date:1a7G7y
Municipality of Anchorage
Development Services Department
Building Safety Division
Onsite Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWERIWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-134-11
Property owner(s) MM and M Contracting, Inc. Day phone 666-1236
Mailing
P.O. Box 670495 Chugiak, AK
Code 99567
Site address 7hdmtan Street Chugiak, AK Zip Code 99567
Legal description (Sub'd., Block & Lot) Lot 5, Denali Vue Subdivision
Legal description (Township, Range & Section)
Lot Size 54.671 Sq. Ft.
THIS APPLICATION IS FOR (® all that apply):
Absorption Field
El
Septic Tank
0
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms Four (4)
THIS APPLICATION IS AN:
Initial
0
Upgrade
❑
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
of property owner or authorized agent)
Permit/Rush Fees: LI(rn — Waiver Fees:
Date of Payment:
Receipt Number.
(Rev. 11105)
1�1 /III /05
Date of Payment:
Receipt Number.
ANDERSON ENGINEERING
P.O_ BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
July 16, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 5, Denali Vue Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 5, Denali Vue Subdivision intends to construct a new four-bedroom
home on the lot. We are therefore requesting a permit be issued for the construction of
a new septic system to accommodate the home. The lot will be served by a community
water system. The attached Site Plan and backup documentation identify the location
and configuration of the proposed septic system along with the alternate site. No
existing wells or septic systems are closer than 100' from the proposed well or septic
system. Drainage arrows are shown on the site plan showing the grade and direction of
flow on the lot. The drainage pattern will not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated silty sand with gravel (SM). The percolation rate of the soil was determined to
be between 1 and 5 minutes per inch. Groundwater was found at 11' below the surface
during the placement of the test holes and rose to 10' below the surface during the
monitoring period. An application rate of 1.2 gallons per day per square foot was used
in the design of the absorption system. We are proposing to place a new 1,250 -gallon
septic tank and a 70' long by 5' wide by 2' effective depth absorption trench to treat and
dispose of the effluent generated in the house. The elevation of the distribution line in
the absorption trench will be 3' below the surface and the total depth will be 5'. A
minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption
trench and 4' over the septic tank.
The ground surface on the lot in the area of the absorption trench slopes to the east at
a grade approximating 2%. The new trench will be constructed parallel with the slope
as much as possible in conformance with Municipal requirements. The new septic
system will be constructed a minimum of 100' from all wells and any surface water and
Lot 5, Denali Vue Subdivision
July 16, 2008
Page Two
10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
7-1-� (f aa -.n
Michael E. Anderson, P.E.
Attachments
V'C'A''. C. d\.;4 4'.^N
®ExfaHnq
Well
^ L13
L11
LOT 6
328,468 S.F.
7.54 ACRES
VACANT
10' T. do E.
10' T. do E. ESMT.
e, �y 1
' 49th
r '
....::.......
A�
I. MICHAEL r. AH➢ER$pJ
?e
m
y
0
0
Ln
N
5
LOT 8
521,000 S.F.
11.96 ACRES
VACANT
P Eq T E R S G A TIE
Existing
® Well
3
w
0o .
u7 n
i0
� v
N
O
LOT 5 •�
54,671 S.F.p�
1.26 ACRES yro
yp rye.
5
S 01'25'46'E
153.50'
AREA MAP
SCALE V = 100'
STREET
1318.94'
1319.62'1
S U B D.
4
!0' T. k E. ESMT.
SECTION UNE ESM
LOT 7
426,396 S.F.
9.79 ACRES
VACANT
DENALI VUE SUBDIVISION
LOT 5
54,671 S.F.
—3' Sectlon Lina Eoaement
I 20' T. h E. Easement
—1---------------
I
I
I _�_r�aaC H Ga4
I
I
THORNTON DRIVE
S 89'58'58'E 241.03'
--------------------------
-- ---- --- Y --- — ----e --
E
fo
S 89'58'58E 153.50'
Four Bedroom
Home
n J12*'
M
1,250 Gallon
. Septic Tank
OTH2 ®TM1 70' Lorq x S' Wide
x Y Etle<tive Depth
Atiaorptlon Tren<n
Alternate Ste
bl
al
SITE PLAN
SCALE V = 40'
jy
4t
MICHAEL E. ANDERSON
T
m
R
m
13
LOT 5, DENALI VUE SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home 5' Wide Trench System
Perc. Rate: <5 Min./Inch 1.250 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 2' Drainfield Rock
4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area
500 SF/5 SF/LF'.7 (Red. Factor) = 70 LF Trench Length
THEREFORE: Construct a 70' Long x 5' Wide x 2' Effective Depth Aborption Trench at the
Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth
to be 5' Belcw Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide
2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area.
Natural
Backfill
2'6"
LA
2'0"
5'
TYPICAL WIDE
Geotextile
Fabric
4" Perforated
PVC (Holes Down)
Drainfield Rock
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 150' Separation From Class C Well in the Area.
Minimum 100' Separation From Surface Water or Streams. .
Minimum 10' Separation From Water Service Line.
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 ELMORE STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION. LOT 5, DENALI VUE S/D
PERFORMED FOR: MM&M CONSTRUCTION
DATE: 5/27/2008 PROJECT No.: M0820
PARCEL ID#: TECHNICIAN: A. HARALA
TEMP: 48°
DEP'111 TEST HOLE # 1
(fcc0
v-rr-i
I
2
READING
OB/OG FROST TO I'
sLUVI
DEPTH OF
WATER
(INCHES)
INET DROP
(INCHES)
3
TEST HOLE PRESOAKED PRIOR TO TESTING:
4
_
N
CHARGE
.
SILTY SAND WITH GRAVEL (SM)
in
5
30
MEDIUM DENSE
3e
3
14:24
6
12.125
CHARGE
4
14:54
30
7
9.75
5
14:54
COBBLES TO 3"
11.625
CHARGE
6
8
30
1.875
9.75
9
I
11--4..;'-
13
14
15
16
17
18
19
SITE PAN
0 O
2 I
WAS GROUND WATER ENCOUNTERED? YES
IF YES@WIWT Or' II' O%
DEPTIi OF WATER AFTER MONRORING: 10' S%
Q DATEOFMONITORWG: ry010% 2
2-5%
BOH
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH OF
WATER
(INCHES)
INET DROP
(INCHES)
5/27/08
TEST HOLE PRESOAKED PRIOR TO TESTING:
1
13:54
11.5
CHARGE
2
14:24
30
1.625
9.875
3
14:24
12.125
CHARGE
4
14:54
30
2.375
9.75
5
14:54
11.625
CHARGE
6
15:24
30
1.875
9.75
PERCOLATION RATE 3.1 (MIN/NCH) PERC. HOLE DIA_ 6 (INCHES)
TEST RUN BETWEEN. 4_5 FT. and 5_5 FI'.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS TEST
WAS PERFORMED N ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES N EFFECT ON THIS
DATE: 7/17/2008
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 ELMORE STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 5, DENALI VUE S/D
PERFORINIED FOR: MMBM CONSTRUCTION
DATE: 5/27/2008 PROJECT No.: M0820
PARCEL ID#: TECHNICIAN: T. L. KIMBROUGH
D[PTFI
TEMP: 48°
TEST HOLE # 2
Irl T�
1
2
3
4 ]< -
5 ,..
6
7
8
9
11
12-
13-
14-
15-
16-
17
21314151617
18
19
OB/OG FROST TO I'
SILTY SAND WITH GRAVEL (SM)
MEDIUM DENSE
MOIST
SITE PAN
OH2 O
T
TRI
WAS GROUND WATER ENCOUNTERED? YES
IF YES rGT WI{ATD li 0%
Q DEPTH OF WATER AFTER MONITORING: 10' 25%
DATE OF MONITORING: 6iI I,0B
2-5
BOH
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
Dy ATER F
(INCHES)
NET DROP
I (INCHES)
5/27/08
TEST HOLE PRESOAKED PRIOR TO TESTING:
1
14:00
11.625
CHARGE
2
14:30
30
3.5
8.125
3
14:30
12.25
CHARGE
4
15:00
30
4.375
7.875
5
15:00
11.625
CHARGE
6
15:30
30
3.625
8.0
PERCOLATION RATE; -3-8 (MNIMCH) PERC. HOLE DIA, (INCIIES)
TEST RUN BETWEEN: L--5 FT. and 5.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. SAME SOIL AS THI.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS TEST
WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 9/11/2007
h
�A
n
l ■ C.
NNW 11'
t
■
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Elmore St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: Anderson Enaineering
Legal description: Denali Vue: Lot 5
®Permit ❑C.O.S.A. []Inspection Report
The attached paperwork has been reviewed and Is being returned for the following reasons:
1. Proposed Design - Engineer's Seal: The proposed design is required to be sealed by the
engineer -of -record. Please provide.
7/28/08 COMMENT REMAINS: The response to comments submittal does not include the
elevation view with design criteria for the absorption field or soils logs. Please submit these
documents with the engineer's seal, signature, and date.
2. Topography - Slope Gradient and Direction: The site plan shows slopes that do not appear to be
correctly describing the site topography. Please revise the site plan as needed to show the
correct slope gradient and direction. 7/28/08 SATISFIED.
Name of reviewer: Jay
Date: 7/22108, 7128108
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
F
Parcel I.D. 051-134-11
Municipality of Anchorage
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval
1. GENERAL INFORMATION
Expiration Date: _
S -1g-/S
� RUSH1 `
MAY 14 2015
Complete legal description Denali Vue, Lot 5 �-
Location (site address) 19834 Thornton Street Chugiak, AK 99567
Current Property owner(s) MM&M Contracting, Inc. Day phone 688-1236
Mailing address P.O. Box 670495 Chugiak, AK 99567
Real Estate Agent
2. TYPE OF DWELLING:
[K] Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: Four
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL: -
Individual Well
❑
Individual
El
Individual Water Storage
❑
Holding Tank
❑
Community Class C Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNarancerequest for: Absorption Trench to Foundation Distance: 81
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer. -
COSA Fee $ J i l , to S Waiver Fee $ Zt r5 • dV
Date of Payment Date of Payment
Receipt Number �^ Receipt Number dmf
COSA #�L'lr7lr�dCJ Waiver# �SvJ5J�7
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
Supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm
Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Michael E. Anderson, P.E. Date 5/14/2015
Engineers Printed Name ®o®V ®a®e _
OF,A4kaa+
6. DSD SIGNATURE ...........I NOINEERf8.......... 0
System #1 Approved for 1 bedrooms ' Y �. MICHAEL . 7 ERSON 4 p
�0 "i'. GE -4381
System #2 Approved for _ bedrooms ♦Osis ••�•��, �++
0
Foe.. 40 V
Disapproved tit994R 17ESS1Q44*
Conditional approval for bedrooms, with the following stiput�tRi1;!8'
By:bum'
Original Certificate Date:
Therage Development Services Division (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSAbluesheel ( :- -, c
If more than 1 septic system is on the lot:
COSA Checklist # _of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Denali Vue, Lot 5
A. WELL DATA
Well type Class C If A, B, or C provide PWSID #
Date completed Sanitary seal (Y/N)_
Total depth ft. Cased to ft.
FROM WELL LOG
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate ND mg/L
Arsenic ND ug/L Dateofsample: 5/11/15
Parcel ID: 051-134-11
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground) in.
AT INSPECTION
ft.
g.p.m.
Collected by: Anderson Engrg.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 7/21/08
Tank size 1'250 gal. Number of Compartments 2 Cleanouts (Y/N)
Foundation cleanout (YIN) Y Depression over tank (Y/N) N High water alarm (Y/N)
Date of pumping New Const. Pumper
C. ABSORPTION FIELD DATA
Y
N
Date installed 7/21/08 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type 5' Wide
Length 70 ft. Width 5 ft. Gravel below pipe 2 ft.
Total depth 9-10 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Const. Results (Pass/Fail) For—bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final Fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
No Add On Manhole - Gravity Flow to Absorption Trench.
D. LIFT STATION
Date installed
Size in gallons Manhole/Access (Y/N)
"Pump on" level at in.
"Pump off' level at in. High water alarm level at
Datum
Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot
On adjacent lots
Absorption field on lot
On adjacent lots
Public sewer manhole/cleanout
Public sewer main
Sewer /septic service line
Holding tank
Manure/animal excrete storage areas _
Animal containment areas
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >51 Property line >5r
Water main
>10, Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
$ **
Property line > 10' Building foundation
Water Service line >10 Surface water
>100'
1
Curtain drain
None Noted Wells on adjacent lots >100'
F. COMMENTS
**See Waiver.
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 5/14/2015
COSA brown sheet_10.1412.doc
2.**
Absorption field
Surface water >100'
Water main
>10'
Driveway, parking/vehicle storage >1 0,
n
.q
AEL E. ANDERSON : - �
CE -4381
PLAT NO. 2005-152
DENALI VUE SUBDIVISION
LOT 5
54,671 S.F.
LOT 6
DRIVEWAY ESMT. FOR THE
BENEFIT OF LOT 5
(2015-000478-0) —
i
i
ZZ 10' T. & E. ESMT. � -
-----------7 -
N 87°00'45"E
- - - - -
- - -
- - - - - - - -
- - - - - --- +
GASTALDI LAND
- -
SURVEYING, LLC
�
I
I
I
I
2000 E. DOWLING RD.. SUITE 8
COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 99507
APPEAR ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-5454
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
GRID
o
I
NW1261
5/14/2015
ESTABLISHING BOUNDARY OR FENCE LINES.
WJ
%
I
ANCHORAGE RECORDING DISTRICT, ALASKA
�
I
U'
I
I
DENAL15
LOT
5
I
I
.
77.9'
I
I
I
$�
2
SEPTIC SYSTEM h
�v
Ny
P
'K
'v11i ^O
(UPJ
I
I
I
104.6'
Ssaa
0
h�
I
I
I
I
`�sR.t
I
NI
F
to
7
?
e28.
20' T. & E. ESMT.
3' SECTION UNE ESMT.
S 89°56'58"E 144.07'
\
\ I
I
\
\ I
I
\ \
I
20' WATERLINE ESMT.—
—` I
\ \
(2013-032440-0)
I
1
LOT 7
A S- B U I L T
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
GASTALDI LAND
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
SURVEYING, LLC
IT IS THE RESPONSIBILITY OF THE OWNER TO
JEFF A. GASTALDI, R.L.S.
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
2000 E. DOWLING RD.. SUITE 8
COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 99507
APPEAR ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-5454
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
GRID
DATE
HEREON BE USED FOR CONSTRUCTION OR FOR
NW1261
5/14/2015
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
F.B.
JOB NO.
NOTE: NO CORNERS SET THIS DATE
2010-03
DENAL15
P)30'
0
N
IR
w
z
0
z
of
0
F
♦s♦•
111=40'
BUILDING DETAIL
SCALE: 1 "=20'
OF q +1
* ' 49TH
r ................. * i
0 w -Jeffery
A. Gataldi ff
: LS 6091.s Air
*/ .
6 401