HomeMy WebLinkAboutDENALI VUE LT 4benall'o Vue Lot 4 #051-134-10 Inspection Report_1 1-12.doc Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP131129 PID Number: 051-134-10 Ej New ❑ Upgrade Name: ABSORPTION FIELD Troy Davis Homes ❑ Deep Trench ❑,' Shallow Trench ❑ Bed ❑ Mound Address 165 E. Parks Highway Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 357-9394 3 .BGPDlSF 8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4 Ft. Gravel depth beneath pipe 4Ft. Subdivision Block Lot Denali vue 4 Fill added above original grade 0-1 Ft. Gravel length - 57 Ft. Township Range Section Gravel width - SFt. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 570 Flz One I Fl. Well >100' >100' N/A N/A 125, TANK El Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,OOOGal. Surface Water >100' >100' N/A N/A Material Steel Number of compartments Two Lot Line >5' >10' N/A N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Pump on level at Pump off level at High water alarm Remarks in. in. - Pump make and model Electrical Inspections performedPIPEMATERIAL ]by Housetotank D3034 Tank to D3Installer drainfieldNorthern Excavation orainfleld F810 CO/MT D3 Inspector MEA BENCH MARK (Assumed elevation) 100.Oft Inspection 1• 10/25/13 10/26/13 Location and description dates: 2.a Garage Slab.. - 3" 11/15/13 a COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL ®�ttl►�1� Conditional Approval: Date ®� '•; f a► e &Ow*.* 49 U ; ..• os s•e• ....... p.. :............. E. ANDERSON e: ♦ moi'. CE -4381 g �,`rl„••e /LSO —11 Approved l�1'Fp'•..•...••�L`�4 � Date (oC.-3 D- ,��rESS10 . `�� Inspection Report_1 1-12.doc Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Permit No: OSP131129 7 N8232"F 180.50 Page 2 of 3 PID No.: 051-134-10 30.00 E— E- U) —FU) Iz 0 F z w O x F ALTERNATE SITE: 15 Long—. 5 Wide x 4' Alternate Effective Depth Absorption Site Trench. Application Rate 4 DF ,%' TH1 C4 M1 TH2 ( w ® w z J ® M2 I z A 8 C CS 81 15.5' 26.3' S2 16.1' 30.0' M1 17.3' 37.3' lI Lo O C4 18.9' 38.3' C5 58.8 33.7' - M2 r 1 O 0 55.6' 33.2' n � c E.My ExiRY L4 (O w Iwl 0 N ..E Three BeMoom rouse I o oD 7cxaaasEa MoPo SVM, M N 0 Z ��xeoxl I r� NOTE: Water Service Location From Contractor Notes. 30'x80' ACCESS ESMT. RECORDED IN BOOK 2034 PACE 3613 33' SECTION LINE ESMT. T _ 20' T.& E. ESMT. _� 10' UTILITY ESMT. 12' TRAIL ESMT, 50.00 gCq��♦i N89°59'56"W 200.50 •����•�F�� �. P( .......... ••..>} ♦1 8 i ° 49th �.....i. ............ ................ •....A i.,.......:....^..`..^:..�`.`.`:: i I -• MICHAEL E. ANDERSON ♦0�:• NO. CE -4381 PLAN AS—BUILT .'.: • ♦♦I�p •�^�°�„�• - SCALE 1' =-40' E— E- U) —FU) Iz 0 F z w O x F Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP131129 N U � H n n 97.3 8 92.8 88.81 81.0 No Groundwater 10-25-13 98.4 U) �y UU 1,000 Gallon Septic Tank FDrainfeldRock PROFILE AS -BUILT - No Scale PID No. 051-134-10 Ni MU lT, 88.81 92.8 A L 2013-032440-0 A s Recording District 301 Anchorage A 06110/201312:56 PM Page 1 of 4 EASEiV T THIS EASEMENT AGREEMENT is made by and between MM&M Contracting, Inc., an Alaska corporation, as owners of the Servient Parcel (hereafter "Grantors"), whose address is P. O. Box 670495 Chugiak, AK. 99567 and BRENDA ELLIOTT BOWLER, an individual, as owner of the Dominant Parcel (hereafter "Grantee", whose address is P. O. Box 772828 Eagle River, AK 99577 1. The parties recite that: A. The Grantors own real property located at Lot 7 Denali Vue Subdivision. Chugiak, Alaska, and legally described as: Lot 7, DENALI VUE SUBDIVISION, according to Plat No. 205-152, records of the Anchorage Recording District, Third Judicial District, State of Alaska. The MM&M'S property as so described is hereafter referred to as the "Servient Parcel." B. Grantees own real property in Chugiak, Alaska, located adjacent to the Grantors. Grantees adjacent property is legally described as: Lot 4, DENALI VIDE SUBDIVISION, according to Plat No. 205-152, records of the Anchorage Recording District, Third Judicial District, State of Alaska. Grantees property as so described is hereafter referred to as the "Dominant Parcel." C. Grantees desires to obtain from the Grantors, and the Grantors desires to grant to the Grantees a water Ime easement on the Grantors property. NOW, THEREFORE, in consideration of the mutual promises made herein, and for other good and valuable consideration, the receipt and sufficiency of which is acknowledged, the parties agree as follows: 2. Grant of Water Line Area Easement on Serviant Parcel: The Grantors, hereby grant and convey to the Grantees, and to its successors and assigns, an easement in and on the Servient Parcel for a water line easement which is particularly described as: An area 20 feet wide and approximately 257.55 feet long as set forth and described on the attached Appendix I Description/sketch, by Gastaldi Land Survey dated Aug. 25, 2010. This water line easement shall be for the purposes of installing, repairing and maintaining a water line from the shared well located on Lot 7 to Lot 4 as noted on the attached description and survey. This easement shall not in any manner be dedicated for. or subject to, use by the public. With the exception of the limitations described above. Grantor shall retain the right to use the water line easement area for any purpose, not otherwise prohibited by law or the covenants, conditions and restrictions applicable to the property, provided that no action by Grantor or use of the waterline easement area shall result in any obstruction being placed in this area that would prevent the Dominate Parcel from being able to repair, replace, maintain the water line servicing the Dominate Parcel. 3 Run With Land: The easements granted and created by this Agreement are intended to and shall run with the land, with the benefit of the easement appurtenant to the respective Dominant Parcel and the burden of the easement appurtenant to the respective Servient Parcel. 4. Duration of Easement: The easement granted and created by this Agreement shall be perpetual, except that this easement shall terminate if the Dominant Parcel is connected to a private or public water system bringing in water from other than the well on Lot 7 or a shared well from Lot 5, 5, or 8 Denali Vue Subdivision. IN WITNESS WHEREOF, the parties have executed the Easement on the dates indicated below. M M & M CONTRACTING, INC. Dated: !! Michelle Myers, President Owner, Servient Parcel BRENDA ELLIOTT BOWLER by 2 Page 2 of 4 X013-C324&C-C Bowler as Attorney in Fact Dated: ` 4 f 1 67"'x`— t Dominate Parcel STATE OF ALASKA ) ss THIRD JUDICIAL DISTRICT } The foregoing instrument was acknowledged before me this 4 �/ day of 2013, by Michelle Myers, President of M M & M Contracting, Inc., an Alaska corporation; on behalf of the corporation. Notary Public in T for Alaska �'t1,3 .• =`4 M Commission xgires: STATE OF ALASKA ) ) ss THIRD JCTDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this (o w�� day of 3 --Gln 6 2013, by Allen O. Bowler, Attorney in Fact for Brenda Elliott Bowler owner of Lot 4 Denali Vue Subdivision. Notary Public in ai6efor Alaska My Commission Expires: _� -� 014, AFTER RECORDING RETURN T0: MM&M Contracting Inc.' P. O. Box 670495 z P; ChugWc, AK. 99567 tom_ t 111111111111 Hillpf, 3 Sage 3 of 4 2093.032446-0 QRSTRL4i L;M SLRkEy l�rr o l X — '— Aug, 25 20i0 - NY _ N 87°00'45"E_ 7` t { tff i i ((.r7t• ;�at1 CJ .. 01 1 � f 7�l I [3 9 t i rt LOT 5 t e i l i t I 4 I ei sPTIsoo _ S Sawn -E 145.07's 1p •f i i t 1 1 t � ] t I 1 3 I CDMXW OF 20' f 7 t i WAIERUNG. ESW. 3 EXHW A LLT"# I t i WnI/ SWMN 1£,1't5�t, RlW. SK ALASKA MORM CBSM= t � I E } tt s LM 4 r 201 T. be E F tf Page 4 of S 2013-032440-0 907-761-2646 08:13:51 a.m. 12-20-2013 2/2 NON -OBJECTION TO EASEMENT ENCROACHMENT DOCUMENT By this document Matanuska Telephone Association, Inc. (MTA) declares that it has no objection to the encroachment of a water (service) line within the 20' telecommunications and electric easement located upon Lot 4, Denali Vue Subdivision, Plat No. 2005-145, Anchorage Recording District, Third Judicial District, State of Alaska. Please be advised that MTA through the issuance of this document does not forfeit any of its rights to the use of the area cited. In the exercise of these rights MTA will, if needed, upgrade, maintain, repair, and/or replace buried or aerial telecommunications facilities within the easement. Any repairs that may be required to the encroachment as a result of utility construction will be borne by the property owner of record. This document does not authorize the placement of any additional encroachments within the easement area. Property owners are required to obtain utility locates before doing any kind of work in the utility easements and will be liable for any damages caused by their construction work in the easements. This document is in no way an agreement to vacate any portion of the utility easement and should not be interpreted as such. Issued for Matanuska Telephone Association, Inc. this 19th day of December, 2013, by, , Manager, OSP Engineering and Construction THIS IS TO CERTIFY, that on this 19th day of December, 2013, before me the undersigned, a Notary Public in and for the State of Alaska, duly commissioned and sworn as such, personally appeared Robbie Nash known to me and to me known to be the individual named in and who executed the foregoing instrument and acknowledged to me that he signed and sealed the same as a voluntary act and deed for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. Notary Pu lic in�arid for/Alaska My co ission expires: 11-20-2014 GRANTOR: Matanuska Telephone Association Inc. - Local PO Box 3550 _ Long Distance Palmer Alaska 99645-3550 - Wireless 800.746.9510 Business Solutions 907.761.2510 Internet 907.761.2646 (fax) Directory www.mtasolutions.com DN A64TANUSKA ELECTRIC ASSOCIATION, INC. LETTER OF NON -OBJECTION December 26, 2013 Troy Davis Homes 165 E. Parks Highway, Suite 200 Wasilla, AK 99645 Re: Lot 4, Denali Vue Subdivision (Plat 2005-152, Anchorager Recording District) Dear Troy Davis Homes: MEA has no objection to the encroachment of a copper water line buried at least ten feet deep located in the utility easement as depicted on the attached as -built survey drawing, subject to the following conditions: 1. The improvement will in no way restrict or limit the current or future ability of MEA to fully enjoy the benefits of the easement for any and all utility purposes that it presently enjoys under the easement. 2. MEA will be held harmless by the landowner from liability for any and all damages or injury to any person or property that may result from the existing and future use of the easement by MEA, its contractors, or assigns. 3. MEA will be held harmless by the landowner for any and all liability arising out of or relating to any use of the easement by others under a Letter of Non -Objection. 4. The landowner will be liable for any damages caused to MEA facilities by the improvement in the easement. 5. The landowner will be responsible for any special construction costs incurred by MEA due to the improvement in the easement. 6. The landowner will assure compliance with all applicable safety codes relating to the improvement in the easement. 7. Use of this letter by the landowner, their successors or assigns will constitute acceptance of these conditions. 8. Alteration of these conditions shall invalidate this letter. 9. This letter is not effective unless it is recorded in the Anchorage Recording District before ownership of the referenced property is changed from the above named landowner. Sincerely, Keith Quintavell Right -of -Way Administrator STATE OF ALASKA)SS- THIS IS TO CERTIFY that on this 26 day of December, 2013 before me, the undersigned, a Notary Public in and for the State of Alaska, duly commissioned �a%nd sworn as such, personally appeared k e,1i 4 Q1Aih4c%V' Known to me and to me known to be the individual(s) named in and w ootmp", the foregoing instrument and acknowledged to me that he/she/they signed and sealed the sqgt$.Ql act and deed for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and 0 I seal the day anp ye&r first above written SEAL j �a,/j rR r�-h r Notary Public in and of Alaska My commission expires 'iris, vi�.�/� VP• "�p� Return to: MEA, PO Box 2929, Palmer, AK 99645 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131129 Tax Code Number: 05113410000 Work Type: Septic Permit Effective Dates: October 22, 2013 to October 22, 2014 Design Engineer: ANDERSON ENGINEERING Subdivision: DENALI VUE Site Legal Address: DENALI VUE LT 4 G:1261 Owner/Address: BOWLER BRENDA ELLIOTT 1720 WESTVIEW CIRCLE ANCHORAGE AK 995042934 Site Mailing Address: 19620 THORNTON ST, Chugiak This permit is for the a nstruetion-of: Y Disposal Field Y Septic Tank N Holding Tank 8,AZ O� s 10� 6 /3 Lot Size in Sq Ft: 54478 Total Bedrooms: 3 N Privy N Private Well N Water Storage 3 30 All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. 1. The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.B.3 Two percolation tests needed. 2. The Inspection Report will not be approved without letters of non objection for the waterline in the T&E easement. 3. The Inspection Report will not be approved until a copy of the community well easement for lot 7 is submitted. Received By: Issued By: 10 ,;P• t Date: Municipality of Anchorage Development Services Division On -Site Water and Wastewater Program went S' a E O F� t Y n Department **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP131397 COSA#: PID#: 051-134-10 Legal Description: Denali Vue L4 Engineer: Anderson Engineering Applicant: Brenda Bowler Permit#: OSP131129 Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 14.0 feet. The alternate site is proposed to be 42 feet from an excessive slope. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: w ZZ l Approved by: AZIA V Name of Reviewer .............................................................. ............... Rae#: 09744G Amount: $200.00 Date Paid: 10121113 **** VARIANCEMAIVER REVIEW **** MUNICIPALITY OF Community Development Department Development Services Division On -Site Water & Wastewater Program ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERNWELL PERMIT APPLICATION Parcel I.D. 051-134-10 Property owner(s) Brenda E. Bowler Mailing address 1720 Westview Circle Anchorage, AK 99504 Day phone Site address 19670 Thornton Street Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Denali Vue, Lot 4 Legal description (Township, Range & Section) Lot Size 54,478 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial 0 Single Family (SF) (w/wo ADU) Septic Tank 0 Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: '5�50 Date of Payment: I D It 3 Receipt Number: bIJ$a-CA Permit No. O")'Q( 6 \) d'� Permit App_9-1-12.doc Waiver Fees: $2.00 Date of Payment: Receipt Number: D y71I Lf (rr Waiver No.D `�� 1313 cf 7 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766(FAX) June 10; 2013 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Denali Vue Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The owner of Lot 4, Denali Vue Subdivision intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. No existing wells or septic systems are closer than 150' from the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated sand and gravelly sand (GM/SM) with some silt. The percolation rate of the soil was determined to be 8 minutes per inch. No groundwater was found and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000 -gallon septic tank and a 57' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4' below the surface and the total depth will be 8'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the northwest at a grade approximating 22%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 150' from the Class C well in the area and 100' from any surface water and 10'. Lot 4, Denali Vue Subdivision June 10, 2013 Page Two If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments -�; �. agtn_ .. MICHAEL E. ANDERSON NO. CE -4381 LOT 7 DENALI VUE VACANT N89'59 56"W 200.50 Septic Area (Approximate) CHUGACH PARK ESTATES 8 ------ *p�llllvljkll ` 49th °ys}�0 e : A I Existing Well ...................... ................ MICHAEL E. ANDERSON o"j 1\ (Approximate) AREA MAP 'ti� ••. No. CE -4381 ,�a \ ♦♦ ,��qiS������••• SCALE 1" = 100' Interval O N sai4 1 / N x'32„E �gp E /SF x herr to Tre h. Site PO/SF CO MT 7 CO TH2 SV 1,00 O / Septi Tank \ \ Three Baaroom HOYBe GAR. F.F. 1118 Possible Well Location x 4• 5- r j)� NOTE: / No Surface Water Within 700' of the Proposed Septic System. � 33' SECTION LINE ESMT20' T.& E. ESWL ' _ 10' UTILITY ESMT. 12' TRAIL ESMT. OF oil N89°59'56"W 200.50 �E glq�4 �P.••.....••• `J-4 �. LEGEND r �p' 4J'r MT - Monitor Tube FCO - Foundation Clean Out 49th TH - Test Hole . ..: ... .... ..... ... ........ CO - Clean Out •.�••.•d•;•-��•��� 2CO - Double Clean Out MICHAEL E. ANDERSON •'Qp r /� H c ; r' No. CE -4381 .'ti, � FL SCALE 1" = 40' 30.00 30.00 LOT 4, DENALI VUE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Three Bedroom House 5' Wide Trench System Perc. Rate: 8 Min./Inch 1.000 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 3 Bedroom X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area 562.5 SF/5 SF/LF*.5 (Red. Factor) = 56.25 LF Trench Length THEREFORE: Construct a 57' Long x 5' Wide x 4' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide Sof Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. Natural Backfill 3'6" Geotextile Fabric 6" 4" Perforated PVC (Holes Down) EN 5' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 150' Separation From Class C Well in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST I LEGAL DESCRIPTION: Lot 4 Denali Vue Subdivision PERFORMED FOR: Troy Davis Homes DATE: 5/11/13 PROJECT No.: PARCEL ID#: TECHNICIAN: JB DEPTH TEST HOLE 1 (feet) 1 OB/OG 2 3 4 5 GM/SM 6 7 8 9 SLOPE SI I L PLAN SEE SITE PLAN x 10 READING WAS GROUND WATER ENCOUNTERED, No IF YES n WHAT DEP CH" NET TIME (MINUTES) DEPTH TO WATER (INCHES) 11 DEPTH Of WATER AFTER MONITORING- None P 5/31/13 1 10:35 3" DATE Of MONITORING'. 6/8/13 E 11:05 12 13 14 15 BOH @ 16' I DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 5/31/13 1 10:35 3" 2 11:05 30 6.75" 3.75" 3 11:06 3.25" 4 11:36 30 7" 3.75" 5 11:38 3.5" 6 12:08 30 7.125" 3.625" PERCOLATION RATE: $ (MIN/INCH) PERC. HOLE DIA. 9 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/31/13 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1 - 2 3 4 5 6 7 8- 9 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 4 Denali Vue Subdivision PERFORMED FOR: Troy Davis Homes DATE: 10/23/13 PROJECT No.: PARCEL ID#: TECHNICIAN: A. Harala OB/OG GM/SM TEST HOLE 2 WAS GROUNDWATER ENCOUNTERED? iiv 1 O IF YES @ WHAT DEPTH? 11 DEPTH OF WATER AFTER MONITORING None 0p C DATE OF MONITORING: 10/25/13 12 1 16 BOH @ 16' 17 18 19 49th E. ANDERSON SITE PLAN SEE SITE PLAN la Y a DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/23 1 3:14 1.25" 2 3:44 30 4.50" 3.25" 3 3:45 1.38" 4 4:15 30 4.40" 3.12" 5 4:16 1.63" 6 4:46 30 4.75" 3.1211 PERCOLATION RATE: 9.6 (MIN/INCH) PERC. HOLE DIA.. f (INCHES) TEST RUN BETWEEN:4_FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/31/13 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX October 21, 2013 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Denali Vue Subdivision Absorption Trench to Slope Waiver Primary and Alternate Site Dear Onsite Services Engineer: Lot 4, Denali Vue Subdivision has limited area for construction of a septic system due to a steep slope to the west and the placement of the large house on the lot. We have located an area with acceptable soils, but it is situated slightly more than 14' from a break in grade greater than 25%. The alternate site is 42' from a break in grade greater than 25% and is included in the waiver. We are therefore applying for a waiver allowing placement of the absorption trenches at the location shown. The imaginary line placed 2.5' above the distribution line and extended down at a 25% grade does not daylight at a distance less than 50' from the edge of the absorption trench. No migration of septic effluent soils. In addition, no development is recommend the waiver be issued. Sincerely, Michael E. Anderson, P.E. ` 49th MICHAEL E. ANDERSON N0. CE 4381 is expected due to the high permeability of the expected to the west of this lot. We therefore � � e®® B1 e 6E Q ♦®45® 0 N z O~ Jr 000 Ln 77 z O U-) L, J % ren Q V 8U1"� A}Jload m LLJ o U� LIJ O LIJ rn O J J o Q (n M z LIJ L o N O N N O N O O U-) O In O un N O O O1 0 I N 9 7 O _—G 0 N i i i � � e®® B1 e 6E Q ♦®45® 0 N z O~ Jr 000 Ln 77 z O U-) L, J % ren Q V 8U1"� A}Jload m LLJ o U� LIJ O LIJ rn O J J o Q (n M z LIJ L o N O N N O N O O U-) O In O un N O O O1 0 Cel 1 gtob Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERIWELL SUBMITTAL COMMENT SHEET To: ANDERSON ENG Legal description: DENALI WE LT4 The attached paperwork has been reviewed and Is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. _ ❑ Topographic information missing or inadequate. _ ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. _ ❑ Well log required. ❑ Omission in narrative. _ ❑ ® Insufficient fill over tank or field._ Other. need toabandon old septic rield eomp}et erth rive�)-�N- W' Z.) ice P1�7 Name of reviewer: JOE GOODALL Date: 5/16/2006 STA' S h-4 19" e' marc 01 LJFc �- � o„kI,Y� •�' Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK TA l k. o To iA y E vrrl pho,1E n AAF /uP, eF ro .Y tnv S ST .talo /Z �/o lot - /'W7 iN r,;kf 041'etl rsoVi 0M), Hill ,� _— •;tl,,,/•. •- e{' t f I ([ e l l iuuul a wlwiisr ^ I ' �iJp�1j1•� 111 I:ti I .. E 1 1 rna1/.al it/. I w c I ! J . 1 • J1y I' ! • 11 ° is:r.a... i • (1 i Q _j I �� I.,II l 11E ,till. t p ivaaryu'moaw.at-----_a_+'•• I• • b tt1 I Icl tt �� 1,1i��1 � IIJ 1 n.//ra1•. ,. 1 � 1111 J t rilaal„!... r !:a ij ilia Mc � ggli !l!1 �� t ! �1�`il'Is31ss1';� I � / !\\ 8 \\\ • s J '; o J� y♦lhn.a»vn.m.J / \ r ! t 1'il '' I l�ll ` ♦IIIHrplq.a°°'i1/ ' \ Ir' 1 e Iq `< 1 ' /� �l J ;�+ill • ', all, liI.- fill ! I L / s is s : It• ��,, cs 1, /��� !� t!;.! � �`• I �'-- �^ i� 11\''•t • \\ \\ � �it t� 1 �Is�' lit 11 \ \ ! • I • I I / / 1 1 CMYC.CH I I / R°R.f F11..[i III 'Iit i! N jai L� a s ° tl3 - "—�—ta •• t Municipality of Anchorage Development Services Department 111 Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-134-10 Property owner(s) MM&M Contracting, Inc. Day phone 686-1236 Mailing address P.O. Box 670495 Chuglak, AK 99567 Zip Code Site address N",PJ Thomton Street Legal description (Sub'd., Block & Lot) Lot 4, Denali Vue Subdivision Legal description (Township, Range & Section) Lot Size 54,478 SF Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field m Septic Tank 0 Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms Code Four(4) THIS APPLICATION IS AN: Initial 0 Upgrade ❑ Renewal ❑ 1 certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: t 44 D Waiver Fees: Date of Payment: Date of Payment: Receipt Number. 2 OJelfDReceipt Number. (Rev. 11/05) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 May 10, 2006 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Denali Vue Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of the subject property intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the home. Water will be furnished to the lot from the neighboring Class C Well and water system. The proposed water service line is shown on the attached Site Plan. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed water service line, septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes were placed on the lot during the subdivision phase of the project. These holes indicated silty, sandy gravel (S1) in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of between 1 and 5 minutes per inch. Groundwater was not encountered during the original test hole placement, and none was noted on April 30, 1997. Our design includes the placement of a new 1,250 -gallon septic tank along with a 50' long by 5' wide by 4' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 8' below the surface. The distribution pipe will be 4' below the surface. A minimum of 3' of cover will be placed atop the trench and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at varying grades toward the southeast. The ground slope in the area of the absorption trench is approximately 15%. The absorption trench will be constructed parallel with the slope of the ground surface as Lot 4, Denali Vue Subdivision May 10, 2006 Page Two much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from the well on this and on the adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, WIL� ` � Michael E. Anderson, P.E. Attachments Z D r r C .. 180.42' p m g 22'32'00 W P U) CD C I G_ U) i u1 I 0 110 Z Oio I -------- IR 6'I O N I I I O I F—ij Lj I G' I O rrl V I N ED Z Ibo Z C^ �� igs S• --1—V— — I •••••,,, '',1•------------- _---------- tuawao03 oun iw11oK .t[_______ 1 n I -------------------------------------- �A Z 1 t `\\f�� I •ga i� p '� i to ,,03 gwi •tt 3P lum •0t I • P? (S Rs is _ S89 49 56 E 318.58 FROM : COUNTRY REALTY PHONE NO. : 9076881236 TH1 Municipality of Anchorage '-' OF_PARTMENT OF HEALTH 8 HUMAN SERVICES 11.5 `L- Street. Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST ss_ DATE PERFORMED: 411 X97 PERFORMED FOR:–- LEGAL DESCRIPTION: Lot 1 Denali View Township, Range, Section: SLOPE SITE PLAN ••* Organic Overburden 1 Ike TI Frozen to 1' PFM " 'p, 2 .' Organic Silt with Sand 3 e • % and Roots to 3' 4 :0 6 9 7 9 a' • O 10' f% d 11 .d,c Q �, 12 _ 13 'O 14 15 16 17 18 19 S1. Silty Sandy Gravel Rock to 12" with occasional Boulders to 3' Bottom WAS GROUNDWATER NO ENCOUNTEREDt IF YES, AT WNAT DEPTH? OtNh In WBtr Mer we UPEnCOLAVON RALE n �5— Immultmmch) PEnC HOLE DIAMETER TEST RUN BETWEEN 4.5 FT AND 5-0 FT COMM@NTSc�ilc nT•�aoaked priorrunning percolation test PERFORMED BY: Dee High I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIO@LINES IN EFFECT ON THIS DATE. DATE: n.008 Inev. 41e5) OEM==-= UPEnCOLAVON RALE n �5— Immultmmch) PEnC HOLE DIAMETER TEST RUN BETWEEN 4.5 FT AND 5-0 FT COMM@NTSc�ilc nT•�aoaked priorrunning percolation test PERFORMED BY: Dee High I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIO@LINES IN EFFECT ON THIS DATE. DATE: n.008 Inev. 41e5) LOT4, DENALI VUE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom House 5' Wide Trench System Perc. Rate: < 1 Min./inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 LF (Width)' .5 (Red. Factor) = 50 LF Trench Length THEREFORE: Construct a New 50' Long x 5' Wide x 4' Effective Depth Absorption Trench Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. 3'6" Chi 4'0" TICAL 5'\ Natural Backfill 5' IDE TREN (NO SCALE) Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock H SECTIOP' NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 4, DENALI VUE SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 50' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 4' below the existing ground surface. Total depth of the trench will be 8' below the existing ground surface. A separation distance of 100' from all wells on adjacent lots and 100' between the septic tank and absorption trench and any surface water must also be maintained. In addition, a separation distance of 10' between components of the septic system and any water service line is required. A minimum of 3' of fill is required over the absorption trench and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 4, Denali Vue Subdivision May 10, 2006 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 4, Denali Vue Subdivision May 10, 2006 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5' to 2.5' in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. • Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 =+� Certificate of On -Site Systems Approval Parcel I.D. 051-134-10 1. GENERAL INFORMATION Expiration Date: - 30 -/q Complete legal description Denali Vue, Lot 4 Location (site address) 19670 Thornton Drive Chugiak, AK 99567 Current Property owner(s) Troy Davis Homes Day phone Mailing address 165 E. Parks Highway, Suite 200 Wasilla, AK 99645 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) DEC ( 2013 ❑ Duplex I RUSHY ❑ Multiple Dwellings (Single Family and/or Duplex) "" 3. NUMBER OF BEDROOMS: Three 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual i] Individual Water Storage ❑ Holding Tank ❑ Community Class C Well I] Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for:, Received by: '' Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ �o J� t 3' 1 p Date of Payment _(a t IIJ Ci Receipt Number 9 i Cn COSA # (:)S>Cl 31 la 51 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone Address P.O. Box 240773 Anchorage, AK 99524 522-7773 Engineers Printed Name Michael E. Anderson, P.E. Date 12/30/2013 6. DSD SIGNATURE System #1 Approved for 3 bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, A r` 4 M ,NIC ri*$t�ANDER ^-I -,- sf CE -4381 r so -!7 . `0of sst with the following stipulatioAA-1t, � By: �Z � Original Certificate Date: ),2_ - 3 O - / 3 T uni ipali o horage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSAbluesheel_F :,� c If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Denali Vue, Lot 4 A. WELL DATA Parcel ID: 051-134-10 Well type If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (Y/N)_ Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate N/D mg/L Arsenic N/D ug/L Date of sample: 12/19/13 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,000 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA I 7 g.p.m. Collected by: Anderson Engrg. Date installed 10/25/13 Cleanouts(Y/N) High water alarm (Y/N) Y N Date installed 10/25/13 Soil rating (g.p.d./ft2 or ft2/bdrm) .8 GPD/SF System type 5 Wide Length 57 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 8 ft. Eff. absorption area 570 ft2 Monitoring tube Y Depression over field _N Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes; give date D. LIFT STATION Date installed "Pump on" level at Datum in. Size in gallons Manhole/Access(Y/N) "Pump oft" level at in. High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main Sewer/septic service line NIA >25' >50' On adjacent lots > 100' On adjacent lots > 100' Public sewer manhole/cleanout N/A Holding tank N/A Animal containment areas Manure/animal excrete storage areas >d nn' SEPTIC/HOLDING TANK ON LOT TO Building foundation >5 Property line >5 Absorption field >5 Water main >10, Water service line >10' Surface water >100' Wells on adjacent lots >1 00.1 ABSORPTION FIELD ON LOTTO Property line >10' Building foundation >1 0Water main N/A Water Service line >10' Surface water > 100 Driveway, parking/vehicle storage > 1 Curtain drain None Noted Wells on adjacent lots > 100' I X9161 T1 11;;I11k&I G. ENGINEER'S CERTIFICATION ®���•V,•"i` Qa,� I certify that I have determined through field inspections and P'• °\S•,�®®� review of Municipal records that the above systems are in •,� / A •` 49THJ0 conformance with MOA COSA guidelines in effect on this date. 00..; -3 ..... Engineer's Printed Name Michael E. Anderson, P.E. I� ••• • .elf I m ®MICHAEL EO ANDERSON :••. CE Date 12/30/2013 -4381 ��®rr^,D�r• 11--30-r7.•��`°`A. COSA brown sheet 10-10-12.doc 7 LOT 4 HAS 54,478 SQ.FT. OF AREA GRAPHIC SCALE. i Inch = 40 Feel 20 0 20 40 so Recet of As—built 12-18-13 FOR: TROY DAVIS HOMES FORBES & ASSOCIATES, INC. P.O. BOX 232293 Anchorage, Alaska 99.523 (907) 227-5881 10-13-13 1" = 40' Lot A. Block Grid As -Built Survey NW 1261 2130201 DENALI VILE Drawn by Field Book SUBDIVISION CEF 243 I hereby certify that the property described hereon has been surveyed by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lyingadjacent thereto unless otherwise shown. That no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and todetermine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Listed distances prevail over sealing. Reproduction may cause distortion. 1 CHARLES E. FORBES ". LS -7326 12-18-13 � n 7 30.00 N82°22' 32"C 180.50 SEPPC ------------------ O hm O � 9 iq ;h 93.3 r-1 W Ln W 29.7 m O CD ENTRY Ep 3. G W I� IN T G � O J 20 o mH M A3.0 PROPOSED DRIVEyWAY W N (C) z O 03 x 0 z CARPORT 30.5 F 30'X80' ACCESS ESMT. RECORDED IN HOOK 2034 PACE 3613 33' SECTION LINE ESMT. _ 20' T.& E. ESMT, 10' UTILITY ESMT. 12' TRAIL ESMT. 77 30.00 N89`59'56"W 200.50 8 GRAPHIC SCALE. i Inch = 40 Feel 20 0 20 40 so Recet of As—built 12-18-13 FOR: TROY DAVIS HOMES FORBES & ASSOCIATES, INC. P.O. BOX 232293 Anchorage, Alaska 99.523 (907) 227-5881 10-13-13 1" = 40' Lot A. Block Grid As -Built Survey NW 1261 2130201 DENALI VILE Drawn by Field Book SUBDIVISION CEF 243 I hereby certify that the property described hereon has been surveyed by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lyingadjacent thereto unless otherwise shown. That no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and todetermine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Listed distances prevail over sealing. Reproduction may cause distortion. 1 CHARLES E. FORBES ". LS -7326 12-18-13 � n