Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP131129
PID Number: 051-134-10 Ej New ❑ Upgrade
Name:
ABSORPTION FIELD
Troy Davis Homes
❑ Deep Trench ❑,' Shallow Trench ❑ Bed ❑ Mound
Address
165 E. Parks Highway Wasilla,
AK 99654
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
357-9394
3
.BGPDlSF
8 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4 Ft.
Gravel depth beneath pipe
4Ft.
Subdivision
Block Lot
Denali vue
4
Fill added above original grade
0-1 Ft.
Gravel length
- 57 Ft.
Township Range Section
Gravel width -
SFt.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
570 Flz
One
I Fl.
Well
>100'
>100'
N/A
N/A
125,
TANK El Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,OOOGal.
Surface Water
>100'
>100'
N/A
N/A
Material
Steel
Number of compartments
Two
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>5'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Pump on level at
Pump off level at
High water alarm
Remarks
in.
in.
-
Pump make and model
Electrical Inspections performedPIPEMATERIAL
]by
Housetotank D3034 Tank to D3Installer drainfieldNorthern
Excavation
orainfleld F810 CO/MT D3
Inspector MEA
BENCH MARK (Assumed elevation) 100.Oft
Inspection 1• 10/25/13
10/26/13
Location and description
dates:
2.a
Garage Slab.. -
3" 11/15/13
a
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
®�ttl►�1�
Conditional Approval:
Date
®� '•; f
a►
e
&Ow*.* 49 U ;
..• os s•e• .......
p.. :.............
E. ANDERSON e:
♦ moi'. CE -4381 g
�,`rl„••e /LSO —11
Approved
l�1'Fp'•..•...••�L`�4
� Date (oC.-3 D-
,��rESS10
.
`��
Inspection Report_1 1-12.doc
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
Permit No: OSP131129 7
N8232"F 180.50
Page 2 of 3
PID No.: 051-134-10
30.00
E—
E-
U)
—FU)
Iz
0
F
z
w
O
x
F
ALTERNATE SITE:
15 Long—. 5 Wide x 4'
Alternate Effective Depth Absorption
Site
Trench. Application Rate 4
DF
,%'
TH1
C4
M1 TH2
( w
®
w
z
J
® M2
I z
A 8 C
CS
81 15.5' 26.3'
S2 16.1' 30.0'
M1 17.3' 37.3'
lI
Lo
O
C4 18.9' 38.3'
C5 58.8 33.7' -
M2
r
1
O
0
55.6' 33.2'
n
�
c
E.My
ExiRY
L4
(O
w
Iwl
0
N
..E
Three BeMoom rouse
I o
oD
7cxaaasEa
MoPo
SVM,
M
N
0
Z
��xeoxl
I
r�
NOTE:
Water Service Location From
Contractor
Notes. 30'x80' ACCESS ESMT.
RECORDED IN BOOK 2034 PACE 3613
33' SECTION LINE ESMT.
T
_
20' T.& E. ESMT.
_�
10' UTILITY ESMT. 12' TRAIL ESMT,
50.00
gCq��♦i
N89°59'56"W 200.50
•����•�F��
�. P( ..........
••..>} ♦1
8
i ° 49th
�.....i. ............ ................ •....A
i.,.......:....^..`..^:..�`.`.`:: i
I -• MICHAEL E. ANDERSON
♦0�:• NO. CE -4381
PLAN AS—BUILT
.'.:
•
♦♦I�p
•�^�°�„�•
- SCALE 1' =-40'
E—
E-
U)
—FU)
Iz
0
F
z
w
O
x
F
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP131129
N
U � H
n n 97.3 8
92.8
88.81
81.0
No Groundwater
10-25-13
98.4
U) �y UU
1,000 Gallon
Septic Tank
FDrainfeldRock
PROFILE AS -BUILT -
No Scale
PID No. 051-134-10
Ni
MU
lT,
88.81
92.8
A
L 2013-032440-0
A
s Recording District 301 Anchorage
A 06110/201312:56 PM Page 1 of 4
EASEiV T
THIS EASEMENT AGREEMENT is made by and between MM&M
Contracting, Inc., an Alaska corporation, as owners of the Servient Parcel (hereafter
"Grantors"), whose address is P. O. Box 670495 Chugiak, AK. 99567 and BRENDA
ELLIOTT BOWLER, an individual, as owner of the Dominant Parcel (hereafter
"Grantee", whose address is P. O. Box 772828 Eagle River, AK 99577
1. The parties recite that:
A. The Grantors own real property located at Lot 7 Denali Vue Subdivision.
Chugiak, Alaska, and legally described as:
Lot 7, DENALI VUE SUBDIVISION, according to
Plat No. 205-152, records of the Anchorage Recording District,
Third Judicial District, State of Alaska.
The MM&M'S property as so described is hereafter referred to as the "Servient Parcel."
B. Grantees own real property in Chugiak, Alaska, located adjacent to the
Grantors. Grantees adjacent property is legally described as:
Lot 4, DENALI VIDE SUBDIVISION, according to Plat No.
205-152, records of the Anchorage Recording District,
Third Judicial District, State of Alaska.
Grantees property as so described is hereafter referred to as the "Dominant Parcel."
C. Grantees desires to obtain from the Grantors, and the Grantors desires to
grant to the Grantees a water Ime easement on the Grantors property.
NOW, THEREFORE, in consideration of the mutual promises made herein, and for other
good and valuable consideration, the receipt and sufficiency of which is acknowledged,
the parties agree as follows:
2. Grant of Water Line Area Easement on Serviant Parcel:
The Grantors, hereby grant and convey to the Grantees, and to its successors and assigns,
an easement in and on the Servient Parcel for a water line easement which is particularly
described as:
An area 20 feet wide and approximately 257.55 feet long as set forth and
described on the attached Appendix I Description/sketch, by Gastaldi
Land Survey dated Aug. 25, 2010.
This water line easement shall be for the purposes of installing, repairing and maintaining
a water line from the shared well located on Lot 7 to Lot 4 as noted on the attached
description and survey. This easement shall not in any manner be dedicated for. or
subject to, use by the public.
With the exception of the limitations described above. Grantor shall retain the
right to use the water line easement area for any purpose, not otherwise prohibited
by law or the covenants, conditions and restrictions applicable to the property,
provided that no action by Grantor or use of the waterline easement area shall
result in any obstruction being placed in this area that would prevent the
Dominate Parcel from being able to repair, replace, maintain the water line
servicing the Dominate Parcel.
3 Run With Land: The easements granted and created by this
Agreement are intended to and shall run with the land, with the benefit of
the easement appurtenant to the respective Dominant Parcel and the
burden of the easement appurtenant to the respective Servient Parcel.
4. Duration of Easement: The easement granted and created by this
Agreement shall be perpetual, except that this easement shall terminate if the Dominant
Parcel is connected to a private or public water system bringing in water from other than
the well on Lot 7 or a shared well from Lot 5, 5, or 8 Denali Vue Subdivision.
IN WITNESS WHEREOF, the parties have executed the Easement on the dates
indicated below.
M M & M CONTRACTING, INC.
Dated: !!
Michelle Myers, President
Owner, Servient Parcel
BRENDA ELLIOTT BOWLER by
2 Page 2 of 4
X013-C324&C-C
Bowler as Attorney in Fact
Dated: ` 4 f 1 67"'x`— t
Dominate Parcel
STATE OF ALASKA )
ss
THIRD JUDICIAL DISTRICT }
The foregoing instrument was acknowledged before me this 4 �/ day of
2013, by Michelle Myers, President of M M & M
Contracting, Inc., an Alaska corporation; on behalf of the corporation.
Notary Public in T for Alaska
�'t1,3 .• =`4 M Commission xgires:
STATE OF ALASKA )
) ss
THIRD JCTDICIAL DISTRICT )
The foregoing instrument was acknowledged before me this (o w�� day of
3 --Gln 6 2013, by Allen O. Bowler, Attorney in Fact for Brenda
Elliott Bowler owner of Lot 4 Denali Vue Subdivision.
Notary Public in ai6efor Alaska
My Commission Expires: _� -� 014,
AFTER RECORDING RETURN T0:
MM&M Contracting Inc.'
P. O. Box 670495 z P;
ChugWc, AK. 99567 tom_ t
111111111111 Hillpf,
3 Sage 3 of 4
2093.032446-0
QRSTRL4i L;M SLRkEy
l�rr o l X
— '—
Aug,
25 20i0
-
NY
_ N 87°00'45"E_
7`
t {
tff
i i
((.r7t•
;�at1
CJ
..
01
1
� f 7�l
I [3
9
t i rt
LOT 5
t e
i
l
i
t
I
4
I
ei sPTIsoo
_ S Sawn -E 145.07's
1p •f
i
i
t
1
1
t
� ]
t
I
1
3
I
CDMXW OF 20'
f
7
t
i
WAIERUNG. ESW.
3
EXHW A
LLT"# I
t
i
WnI/ SWMN 1£,1't5�t,
RlW. SK ALASKA
MORM CBSM=
t
�
I
E
}
tt
s
LM 4 r
201 T. be E F tf
Page 4 of S
2013-032440-0
907-761-2646
08:13:51 a.m. 12-20-2013 2/2
NON -OBJECTION TO EASEMENT ENCROACHMENT DOCUMENT
By this document Matanuska Telephone Association, Inc. (MTA) declares that it has no objection to the
encroachment of a water (service) line within the 20' telecommunications and electric easement located upon
Lot 4, Denali Vue Subdivision, Plat No. 2005-145, Anchorage Recording District, Third Judicial District,
State of Alaska.
Please be advised that MTA through the issuance of this document does not forfeit any of its rights to the use
of the area cited. In the exercise of these rights MTA will, if needed, upgrade, maintain, repair, and/or replace
buried or aerial telecommunications facilities within the easement. Any repairs that may be required to the
encroachment as a result of utility construction will be borne by the property owner of record. This document
does not authorize the placement of any additional encroachments within the easement area. Property owners
are required to obtain utility locates before doing any kind of work in the utility easements and will be liable
for any damages caused by their construction work in the easements.
This document is in no way an agreement to vacate any portion of the utility easement and should not be
interpreted as such.
Issued for Matanuska Telephone Association, Inc. this 19th day of December, 2013, by,
, Manager, OSP Engineering and Construction
THIS IS TO CERTIFY, that on this 19th day of December, 2013, before me the undersigned, a Notary Public in
and for the State of Alaska, duly commissioned and sworn as such, personally appeared Robbie Nash known to
me and to me known to be the individual named in and who executed the foregoing instrument and
acknowledged to me that he signed and sealed the same as a voluntary act and deed for the uses and purposes
therein mentioned.
IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written.
Notary Pu lic in�arid for/Alaska
My co ission expires: 11-20-2014
GRANTOR:
Matanuska Telephone Association Inc.
- Local
PO Box 3550 _
Long Distance
Palmer Alaska 99645-3550 -
Wireless
800.746.9510
Business Solutions
907.761.2510
Internet
907.761.2646 (fax)
Directory
www.mtasolutions.com DN
A64TANUSKA ELECTRIC ASSOCIATION, INC.
LETTER OF NON -OBJECTION
December 26, 2013
Troy Davis Homes
165 E. Parks Highway, Suite 200
Wasilla, AK 99645
Re: Lot 4, Denali Vue Subdivision (Plat 2005-152, Anchorager Recording District)
Dear Troy Davis Homes:
MEA has no objection to the encroachment of a copper water line buried at least ten feet deep located in
the utility easement as depicted on the attached as -built survey drawing, subject to the following conditions:
1. The improvement will in no way restrict or limit the current or future ability of MEA to fully enjoy the
benefits of the easement for any and all utility purposes that it presently enjoys under the easement.
2. MEA will be held harmless by the landowner from liability for any and all damages or injury to any
person or property that may result from the existing and future use of the easement by MEA, its
contractors, or assigns.
3. MEA will be held harmless by the landowner for any and all liability arising out of or relating to any use
of the easement by others under a Letter of Non -Objection.
4. The landowner will be liable for any damages caused to MEA facilities by the improvement in the
easement.
5. The landowner will be responsible for any special construction costs incurred by MEA due to the
improvement in the easement.
6. The landowner will assure compliance with all applicable safety codes relating to the improvement in
the easement.
7. Use of this letter by the landowner, their successors or assigns will constitute acceptance of these
conditions.
8. Alteration of these conditions shall invalidate this letter.
9. This letter is not effective unless it is recorded in the Anchorage Recording District before ownership of
the referenced property is changed from the above named landowner.
Sincerely,
Keith Quintavell
Right -of -Way Administrator
STATE OF ALASKA)SS-
THIS IS TO CERTIFY that on this 26 day of December, 2013 before me, the undersigned, a Notary Public
in and for the State of Alaska, duly commissioned �a%nd sworn as such, personally appeared
k e,1i 4 Q1Aih4c%V'
Known to me and to me known to be the individual(s) named in and w ootmp", the foregoing instrument
and acknowledged to me that he/she/they signed and sealed the sqgt$.Ql act and deed for the
uses and purposes therein mentioned.
IN WITNESS WHEREOF, I have hereunto set my hand and 0 I seal the day anp ye&r first above written
SEAL j �a,/j
rR r�-h
r
Notary Public in and of Alaska My commission expires 'iris,
vi�.�/� VP• "�p�
Return to: MEA, PO Box 2929, Palmer, AK 99645
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131129
Tax Code Number: 05113410000
Work Type: Septic
Permit Effective Dates: October 22, 2013 to October 22, 2014
Design Engineer: ANDERSON ENGINEERING
Subdivision: DENALI VUE
Site Legal Address: DENALI VUE LT 4 G:1261
Owner/Address: BOWLER BRENDA ELLIOTT
1720 WESTVIEW CIRCLE ANCHORAGE AK 995042934
Site Mailing Address: 19620 THORNTON ST, Chugiak
This permit is for the a nstruetion-of:
Y Disposal Field Y Septic Tank N Holding Tank
8,AZ O� s
10� 6 /3
Lot Size in Sq Ft: 54478
Total Bedrooms: 3
N Privy N Private Well N Water Storage
3 30
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
1. The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a
percolation test. The Engineer needs to do an additional percolation test prior to the construction
of the septic field. Please submit stamped and signed results with the As -built Inspection Report.
If the results require a design change, construction of the system will stop pending On -Site review
and approval. AMC 15.65.060.B.3 Two percolation tests needed.
2. The Inspection Report will not be approved without letters of non objection for the waterline in
the T&E easement.
3. The Inspection Report will not be approved until a copy of the community well easement for lot 7
is submitted.
Received By:
Issued By:
10 ,;P• t
Date:
Municipality of Anchorage
Development Services Division
On -Site Water and Wastewater Program
went S'
a
E O F�
t
Y n
Department
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSP131397 COSA#:
PID#: 051-134-10
Legal Description: Denali Vue L4
Engineer: Anderson Engineering
Applicant: Brenda Bowler
Permit#: OSP131129
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the excessive slope has been approved. The approved separation distance is 14.0 feet. The
alternate site is proposed to be 42 feet from an excessive slope.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
...............................................................................
Waiver is Granted: X Waiver is not Granted:
Date: w ZZ l Approved by: AZIA V
Name of Reviewer
.............................................................. ...............
Rae#: 09744G Amount: $200.00 Date Paid: 10121113
**** VARIANCEMAIVER REVIEW ****
MUNICIPALITY OF
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWERNWELL PERMIT APPLICATION
Parcel I.D. 051-134-10
Property owner(s) Brenda E. Bowler
Mailing address 1720 Westview Circle Anchorage, AK 99504
Day phone
Site address 19670 Thornton Street Chugiak, AK 99567
Legal description (Sub'd., Block & Lot) Denali Vue, Lot 4
Legal description (Township, Range & Section)
Lot Size 54,478 Sq. Ft. Number of Bedrooms Three (3)
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑ Initial 0
Single Family (SF)
(w/wo ADU)
Septic Tank 0 Upgrade ❑
Duplex (D)
❑
Holding Tank ❑ Renewal ❑
Multiple Dwellings
❑
Privy ❑
(SF and/or D)
Private Well
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Dis tance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: '5�50
Date of Payment: I D It 3
Receipt Number: bIJ$a-CA
Permit No. O")'Q( 6 \) d'�
Permit App_9-1-12.doc
Waiver Fees: $2.00
Date of Payment:
Receipt Number: D y71I Lf (rr
Waiver No.D `�� 1313 cf 7
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766(FAX)
June 10; 2013
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 4, Denali Vue Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer
The owner of Lot 4, Denali Vue Subdivision intends to construct a new three-bedroom
home on the lot. We are therefore requesting a permit be issued for the construction of
a new septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed septic system
along with the alternate site. No existing wells or septic systems are closer than 150'
from the proposed septic system. Drainage arrows are shown on the site plan showing
the grade and direction of flow on the lot. The drainage pattern will not be changed as
a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated sand and gravelly sand (GM/SM) with some silt. The percolation rate of the
soil was determined to be 8 minutes per inch. No groundwater was found and none
was noted during the monitoring period. An application rate of .8 gallons per day per
square foot was used in the design of the absorption system. We are proposing to
place a new 1,000 -gallon septic tank and a 57' long by 5' wide by 4' effective depth
absorption trench to treat and dispose of the effluent generated in the house. The
elevation of the distribution line in the absorption trench will be 4' below the surface and
the total depth will be 8'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be
placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the absorption trench slopes to the
northwest at a grade approximating 22%. The new trench will be constructed parallel
with the slope as much as possible in conformance with Municipal requirements. The
new septic system will be constructed a minimum of 150' from the Class C well in the
area and 100' from any surface water and 10'.
Lot 4, Denali Vue Subdivision
June 10, 2013
Page Two
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
-�; �.
agtn_ ..
MICHAEL E. ANDERSON
NO. CE -4381
LOT 7
DENALI VUE
VACANT
N89'59 56"W 200.50
Septic Area
(Approximate)
CHUGACH PARK ESTATES 8
------
*p�llllvljkll
` 49th °ys}�0
e : A
I
Existing Well
...................... ................
MICHAEL E. ANDERSON o"j 1\ (Approximate)
AREA MAP
'ti�
••. No. CE -4381 ,�a \
♦♦ ,��qiS������••• SCALE 1" = 100'
Interval O
N sai4 1 / N x'32„E �gp
E /SF
x herr to Tre h.
Site PO/SF
CO
MT
7
CO
TH2
SV
1,00 O
/ Septi Tank \ \
Three Baaroom HOYBe
GAR. F.F. 1118
Possible
Well
Location
x 4•
5-
r j)�
NOTE: /
No Surface Water Within 700' of the
Proposed Septic System.
�
33' SECTION LINE ESMT20' T.& E. ESWL ' _
10' UTILITY ESMT.
12' TRAIL ESMT.
OF
oil N89°59'56"W 200.50
�E glq�4
�P.••.....••• `J-4 �. LEGEND
r �p' 4J'r MT - Monitor Tube
FCO - Foundation Clean Out
49th TH - Test Hole
.
..: ... .... ..... ... ........ CO - Clean Out
•.�••.•d•;•-��•��� 2CO - Double Clean Out
MICHAEL E. ANDERSON •'Qp r /�
H
c ;
r' No. CE -4381 .'ti, � FL
SCALE 1" = 40'
30.00
30.00
LOT 4, DENALI VUE SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS
Three Bedroom House 5' Wide Trench System
Perc. Rate: 8 Min./Inch 1.000 Gallon Septic Tank
Application Rate: .8 GPD/SF 4' Drainfield Rock
3 Bedroom X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area
562.5 SF/5 SF/LF*.5 (Red. Factor) = 56.25 LF Trench Length
THEREFORE: Construct a 57' Long x 5' Wide x 4' Effective Depth Aborption Trench at the
Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth
to be 8' Below Existing Ground. Provide Sof Cover Over Trench and 4' Over Tank or Provide
2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area.
Natural
Backfill
3'6"
Geotextile
Fabric
6" 4" Perforated
PVC (Holes Down)
EN
5'
Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 150' Separation From Class C Well in the Area.
Minimum 100' Separation From Surface Water or Streams.
Minimum 10' Separation From Water Service Line.
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST I
LEGAL DESCRIPTION: Lot 4 Denali Vue Subdivision
PERFORMED FOR: Troy Davis Homes
DATE: 5/11/13 PROJECT No.:
PARCEL ID#: TECHNICIAN: JB
DEPTH TEST HOLE 1
(feet)
1 OB/OG
2
3
4
5 GM/SM
6
7
8
9
SLOPE
SI I L PLAN
SEE SITE PLAN
x
10
READING
WAS GROUND WATER ENCOUNTERED, No
IF YES n WHAT DEP CH"
NET TIME
(MINUTES)
DEPTH TO
WATER
(INCHES)
11
DEPTH Of WATER AFTER MONITORING- None P
5/31/13
1
10:35
3"
DATE Of MONITORING'. 6/8/13 E
11:05
12
13
14
15
BOH @ 16'
I
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH TO
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
5/31/13
1
10:35
3"
2
11:05
30
6.75"
3.75"
3
11:06
3.25"
4
11:36
30
7"
3.75"
5
11:38
3.5"
6
12:08
30
7.125"
3.625"
PERCOLATION RATE: $ (MIN/INCH) PERC. HOLE DIA. 9 (INCHES)
TEST RUN BETWEEN: 3 FT. and 4 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 5/31/13
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
DEPTH
(feet)
1 -
2
3
4
5
6
7
8-
9
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: Lot 4 Denali Vue Subdivision
PERFORMED FOR: Troy Davis Homes
DATE: 10/23/13 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. Harala
OB/OG
GM/SM
TEST HOLE 2
WAS GROUNDWATER ENCOUNTERED? iiv
1 O IF YES @ WHAT DEPTH?
11 DEPTH OF WATER AFTER MONITORING None 0p C
DATE OF MONITORING: 10/25/13
12
1
16 BOH @ 16'
17
18
19
49th
E. ANDERSON
SITE PLAN
SEE SITE PLAN
la
Y
a
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
10/23
1
3:14
1.25"
2
3:44
30
4.50"
3.25"
3
3:45
1.38"
4
4:15
30
4.40"
3.12"
5
4:16
1.63"
6
4:46
30
4.75"
3.1211
PERCOLATION RATE: 9.6 (MIN/INCH) PERC. HOLE DIA.. f (INCHES)
TEST RUN BETWEEN:4_FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 5/31/13
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
October 21, 2013
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 4, Denali Vue Subdivision
Absorption Trench to Slope Waiver
Primary and Alternate Site
Dear Onsite Services Engineer:
Lot 4, Denali Vue Subdivision has limited area for construction of a septic system due
to a steep slope to the west and the placement of the large house on the lot. We have
located an area with acceptable soils, but it is situated slightly more than 14' from a
break in grade greater than 25%. The alternate site is 42' from a break in grade greater
than 25% and is included in the waiver. We are therefore applying for a waiver allowing
placement of the absorption trenches at the location shown.
The imaginary line placed 2.5' above the distribution line and extended down at a 25%
grade does not daylight at a distance less than 50' from the edge of the absorption
trench. No migration of septic effluent
soils. In addition, no development is
recommend the waiver be issued.
Sincerely,
Michael E. Anderson, P.E.
` 49th
MICHAEL E. ANDERSON
N0. CE 4381
is expected due to the high permeability of the
expected to the west of this lot. We therefore
� � e®® B1 e 6E Q ♦®45®
0
N z
O~
Jr
000
Ln
77
z
O U-) L, J
% ren
Q V
8U1"� A}Jload m LLJ
o U�
LIJ
O LIJ
rn
O
J J
o Q (n
M z
LIJ
L
o
N
O
N
N
O
N
O
O U-) O In O un
N O O O1
0
I
N
9
7
O
_—G
0
N
i
i
i
� � e®® B1 e 6E Q ♦®45®
0
N z
O~
Jr
000
Ln
77
z
O U-) L, J
% ren
Q V
8U1"� A}Jload m LLJ
o U�
LIJ
O LIJ
rn
O
J J
o Q (n
M z
LIJ
L
o
N
O
N
N
O
N
O
O U-) O In O un
N O O O1
0
Cel 1 gtob
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWERIWELL SUBMITTAL COMMENT SHEET
To: ANDERSON ENG
Legal description: DENALI WE LT4
The attached paperwork has been reviewed and Is being returned for the following reasons:
❑
Original signature or stamp missing on
❑
Calculation error in design. _
❑
Additional soils information needed. _
❑
Water monitoring results inadequate.
❑
Discrepancy in information submitted. _
❑
Topographic information missing or inadequate. _
❑
Incomplete; missing
❑
Incomplete; missing
❑
Additional adequacy test information needed.
❑
Water sample unacceptable. _
❑
Measured/proposed distances/dimensions missing.
❑
Locations of all soils, percolation and water monitoring tests
not shown.
❑
Proposed system too deep for soils information submitted.
_
❑
Well log required.
❑
Omission in narrative. _
❑
®
Insufficient fill over tank or field._
Other. need toabandon old septic rield eomp}et erth rive�)-�N-
W'
Z.) ice P1�7
Name of reviewer: JOE GOODALL
Date: 5/16/2006
STA' S h-4 19" e'
marc 01 LJFc �-
� o„kI,Y� •�'
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
TA l k. o To iA y E vrrl pho,1E n AAF /uP, eF ro .Y tnv S ST .talo
/Z �/o lot -
/'W7 iN r,;kf 041'etl rsoVi 0M),
Hill ,� _—
•;tl,,,/•. •-
e{' t f I ([ e l l iuuul a wlwiisr ^ I
' �iJp�1j1•� 111 I:ti I ..
E
1 1
rna1/.al it/. I w c I
! J . 1 • J1y I' ! • 11 ° is:r.a... i • (1 i Q _j I
�� I.,II l 11E ,till. t p ivaaryu'moaw.at-----_a_+'••
I• • b
tt1 I Icl tt
�� 1,1i��1 � IIJ 1 n.//ra1•. ,. 1
� 1111 J t rilaal„!... r !:a ij
ilia Mc
� ggli
!l!1 �� t ! �1�`il'Is31ss1';� I � / !\\ 8 \\\ • s J '; o
J� y♦lhn.a»vn.m.J / \ r ! t 1'il '' I l�ll ` ♦IIIHrplq.a°°'i1/ ' \ Ir' 1 e
Iq
`< 1 ' /�
�l
J ;�+ill • ', all,
liI.-
fill
! I L
/ s
is s : It• ��,, cs
1, /��� !� t!;.! � �`• I �'--
�^
i� 11\''•t • \\ \\ � �it t� 1 �Is�' lit
11 \ \ !
• I • I I / / 1 1
CMYC.CH I I / R°R.f F11..[i III
'Iit
i!
N jai
L�
a s ° tl3 - "—�—ta •• t
Municipality of Anchorage
Development Services Department
111 Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWERIWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-134-10
Property owner(s) MM&M Contracting, Inc. Day phone 686-1236
Mailing address P.O. Box 670495 Chuglak, AK 99567 Zip Code
Site address N",PJ Thomton Street
Legal description (Sub'd., Block & Lot) Lot 4, Denali Vue Subdivision
Legal description (Township, Range & Section)
Lot Size 54,478 SF Sq. Ft.
THIS APPLICATION IS FOR (® all that apply):
Absorption Field m
Septic Tank 0
Holding Tank ❑
Privy ❑
Private Well ❑
Water Storage ❑
Number of Bedrooms
Code
Four(4)
THIS APPLICATION IS AN:
Initial
0
Upgrade
❑
Renewal
❑
1 certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: t 44 D Waiver Fees:
Date of Payment:
Date of Payment:
Receipt Number. 2 OJelfDReceipt Number.
(Rev. 11/05)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
May 10, 2006
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 4, Denali Vue Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the subject property intends to construct a new four-bedroom home on
the lot. We are therefore requesting a permit be issued for the construction of a new
septic system to serve the home. Water will be furnished to the lot from the
neighboring Class C Well and water system. The proposed water service line is shown
on the attached Site Plan. No conflicts exist with adjacent septic systems or wells and
the proposed septic system on this lot. The attached Site Plan and backup
documentation identify the location and configuration of the proposed water service
line, septic system and alternate site. The current drainage pattern is identified on the
Site Plan. The drainage pattern will be maintained after development of this lot is
complete.
Test holes were placed on the lot during the subdivision phase of the project. These
holes indicated silty, sandy gravel (S1) in the area of the absorption trench and
alternate site. The accepting soils were tested and found to have a percolation rate of
between 1 and 5 minutes per inch. Groundwater was not encountered during the
original test hole placement, and none was noted on April 30, 1997. Our design
includes the placement of a new 1,250 -gallon septic tank along with a 50' long by 5'
wide by 4' effective depth absorption trench to collect and treat the sewage generated
in the house. The bottom of the trench will be 8' below the surface. The distribution
pipe will be 4' below the surface. A minimum of 3' of cover will be placed atop the
trench and a minimum of 4' of cover will be placed atop the new septic tank.
The ground surface on the lot slopes at varying grades toward the southeast. The
ground slope in the area of the absorption trench is approximately 15%. The
absorption trench will be constructed parallel with the slope of the ground surface as
Lot 4, Denali Vue Subdivision
May 10, 2006
Page Two
much as possible in conformance with Municipal requirements. The new septic system
will be constructed a minimum of 100' from the well on this and on the adjacent lots. It
will also be constructed a minimum of 100' from any surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
WIL� ` �
Michael E. Anderson, P.E.
Attachments
Z
D
r
r C .. 180.42'
p m g 22'32'00 W
P U)
CD
C I
G_
U) i u1 I
0 110
Z Oio
I
-------- IR 6'I O
N I I I
O I
F—ij Lj I G' I O
rrl
V I
N
ED
Z
Ibo Z
C^
��
igs
S•
--1—V— — I
•••••,,, '',1•------------- _----------
tuawao03 oun iw11oK .t[_______ 1 n I
--------------------------------------
�A
Z 1 t `\\f�� I
•ga i� p '� i to ,,03 gwi •tt 3P lum •0t I
• P? (S Rs
is _ S89 49 56 E 318.58
FROM : COUNTRY REALTY PHONE NO. : 9076881236
TH1
Municipality of Anchorage
'-' OF_PARTMENT OF HEALTH 8 HUMAN SERVICES
11.5 `L- Street. Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
ss_
DATE PERFORMED: 411 X97
PERFORMED FOR:–-
LEGAL DESCRIPTION: Lot 1 Denali View Township, Range, Section:
SLOPE SITE PLAN
••* Organic Overburden
1 Ike TI Frozen to 1' PFM
" 'p,
2 .' Organic Silt with Sand
3 e • % and Roots to 3'
4 :0
6 9
7
9 a' • O
10' f%
d
11 .d,c
Q �,
12 _
13 'O
14
15
16
17
18
19
S1. Silty Sandy Gravel
Rock to 12" with
occasional Boulders to 3'
Bottom
WAS GROUNDWATER NO
ENCOUNTEREDt
IF YES, AT WNAT
DEPTH?
OtNh In WBtr Mer we
UPEnCOLAVON RALE n �5— Immultmmch) PEnC HOLE DIAMETER
TEST RUN BETWEEN 4.5 FT AND 5-0 FT
COMM@NTSc�ilc nT•�aoaked priorrunning percolation test
PERFORMED BY: Dee High I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIO@LINES IN EFFECT ON THIS DATE. DATE:
n.008 Inev. 41e5)
OEM==-=
UPEnCOLAVON RALE n �5— Immultmmch) PEnC HOLE DIAMETER
TEST RUN BETWEEN 4.5 FT AND 5-0 FT
COMM@NTSc�ilc nT•�aoaked priorrunning percolation test
PERFORMED BY: Dee High I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIO@LINES IN EFFECT ON THIS DATE. DATE:
n.008 Inev. 41e5)
LOT4, DENALI VUE
SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom House 5' Wide Trench System
Perc. Rate: < 1 Min./inch 1,250 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area
500 SF/5 LF (Width)' .5 (Red. Factor) = 50 LF Trench Length
THEREFORE: Construct a New 50' Long x 5' Wide x 4' Effective Depth Absorption Trench
Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be
8' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over
Absorption Trench.
3'6"
Chi
4'0"
TICAL 5'\
Natural
Backfill
5'
IDE TREN
(NO SCALE)
Geotextile
Fabric
4" Perforated
PVC (Holes Down)
Drainfield Rock
H SECTIOP'
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 4, DENALI VUE SUBDIVISION
GENERAL:
1. The scope of this project includes the procurement and placement of a new
1,250 -gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a new 50' long X 5' wide X 4' effective depth
absorption trench at the location also shown on the Site Plan. The
distribution line in the trench will be placed at 4' below the existing ground
surface. Total depth of the trench will be 8' below the existing ground
surface. A separation distance of 100' from all wells on adjacent lots and
100' between the septic tank and absorption trench and any surface water
must also be maintained. In addition, a separation distance of 10' between
components of the septic system and any water service line is required. A
minimum of 3' of fill is required over the absorption trench and 4' over the
septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be
placed.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
4. Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Department of Health and Human Services for system installations.
Owners installing their own systems must receive prior approval from
D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250 -gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 4, Denali Vue Subdivision
May 10, 2006
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
6. Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. Contractor shall verify this condition prior to placement of the
rock. All pockets of unacceptable materials must be removed and replaced.
Lot 4, Denali Vue Subdivision
May 10, 2006
Page 3 of 3
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5' to 2.5' in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as -built of the completed system.
• Municipality of Anchorage
On -Site Water and Wastewater Program
(907)343-7904 =+�
Certificate of On -Site Systems Approval
Parcel I.D. 051-134-10
1. GENERAL INFORMATION
Expiration Date:
- 30 -/q
Complete legal description Denali Vue, Lot 4
Location (site address) 19670 Thornton Drive Chugiak, AK 99567
Current Property owner(s) Troy Davis Homes Day phone
Mailing address 165 E. Parks Highway, Suite 200 Wasilla, AK 99645
Real Estate Agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU) DEC ( 2013
❑ Duplex I RUSHY
❑ Multiple Dwellings (Single Family and/or Duplex) ""
3. NUMBER OF BEDROOMS: Three
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual
i]
Individual Water Storage
❑
Holding Tank
❑
Community Class C Well
I]
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for:,
Received by: '' Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ �o J� t 3' 1 p
Date of Payment _(a t IIJ Ci
Receipt Number 9 i Cn
COSA # (:)S>Cl 31 la 51
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone
Address P.O. Box 240773 Anchorage, AK 99524
522-7773
Engineers Printed Name Michael E. Anderson, P.E. Date 12/30/2013
6. DSD SIGNATURE
System #1 Approved for 3 bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms,
A
r`
4 M ,NIC ri*$t�ANDER ^-I -,-
sf CE -4381
r so -!7 .
`0of sst
with the following stipulatioAA-1t, �
By: �Z � Original Certificate Date: ),2_ - 3 O - / 3
T uni ipali o horage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSAbluesheel_F :,� c
If more than 1 septic system is on the lot:
COSA Checklist # of _
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Denali Vue, Lot 4
A. WELL DATA
Parcel ID: 051-134-10
Well type If A, B, or C provide PWSID # Well Log (Y/N)
Date completed Sanitary seal (Y/N)_ Wires properly protected (Y/N)
Total depth ft. Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
Static water level ft.
Well production g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate N/D mg/L
Arsenic N/D ug/L Date of sample: 12/19/13
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,000 gal. Number of Compartments 2
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N
Date of pumping New Const. Pumper
C. ABSORPTION FIELD DATA
I
7
g.p.m.
Collected by: Anderson Engrg.
Date installed 10/25/13
Cleanouts(Y/N)
High water alarm (Y/N)
Y
N
Date installed 10/25/13 Soil rating (g.p.d./ft2 or ft2/bdrm) .8 GPD/SF System type 5 Wide
Length 57 ft. Width 5 ft. Gravel below pipe 4 ft.
Total depth 8 ft. Eff. absorption area 570 ft2 Monitoring tube Y Depression over field _N
Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes; give date
D. LIFT STATION
Date installed
"Pump on" level at
Datum
in.
Size in gallons Manhole/Access(Y/N)
"Pump oft" level at in. High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100'
Absorption field on lot >100'
Public sewer main
Sewer/septic service line
NIA
>25'
>50'
On adjacent lots > 100'
On adjacent lots > 100'
Public sewer manhole/cleanout N/A
Holding tank N/A
Animal containment areas Manure/animal excrete storage areas >d nn'
SEPTIC/HOLDING TANK ON LOT TO
Building foundation >5 Property line >5 Absorption field >5
Water main >10, Water service line >10' Surface water >100'
Wells on adjacent lots >1 00.1
ABSORPTION FIELD ON LOTTO
Property line >10' Building foundation >1 0Water main N/A
Water Service line >10' Surface water > 100 Driveway, parking/vehicle storage > 1
Curtain drain None Noted Wells on adjacent lots > 100'
I X9161 T1 11;;I11k&I
G. ENGINEER'S CERTIFICATION
®���•V,•"i` Qa,�
I certify that I have determined through field inspections and
P'• °\S•,�®®�
review of Municipal records that the above systems are in
•,� /
A •` 49THJ0
conformance with MOA COSA guidelines in effect on this date.
00..; -3 .....
Engineer's Printed Name Michael E. Anderson, P.E.
I� ••• • .elf
I m ®MICHAEL EO ANDERSON
:••. CE
Date 12/30/2013
-4381
��®rr^,D�r• 11--30-r7.•��`°`A.
COSA brown sheet 10-10-12.doc
7
LOT 4 HAS
54,478 SQ.FT. OF AREA
GRAPHIC SCALE. i Inch = 40 Feel
20 0 20 40 so
Recet of As—built 12-18-13
FOR: TROY DAVIS HOMES
FORBES & ASSOCIATES, INC.
P.O. BOX 232293
Anchorage, Alaska 99.523
(907) 227-5881
10-13-13 1" = 40'
Lot A.
Block
Grid As -Built Survey
NW 1261 2130201 DENALI VILE
Drawn by Field Book SUBDIVISION
CEF 243
I hereby certify that the property described hereon has been surveyed
by me, or at my direction, and that the improvements situated thereon
are within the property lines and do not overlap or encroach on the
property lyingadjacent thereto unless otherwise shown. That no
improvements on the property lying adjacent thereto encroach on the
premises in question and that there are no roadways, transmission
lines or other easements on said property except as shown.
It is the responsibility of the owner or builder, prior to construction,
to verify proposed building grade relative to finish grade and utility
connections and todetermine the existence of any easements, covenants,
or restrictions which do not appear on the recorded subdivision plat.
Listed distances prevail over sealing.
Reproduction may cause distortion.
1
CHARLES E. FORBES
". LS -7326
12-18-13 �
n
7
30.00
N82°22' 32"C 180.50
SEPPC ------------------
O
hm
O
�
9
iq
;h 93.3
r-1
W
Ln
W
29.7
m
O
CD
ENTRY
Ep
3.
G
W
I�
IN
T
G
�
O
J
20
o
mH
M
A3.0
PROPOSED
DRIVEyWAY
W
N
(C)
z
O
03
x
0
z
CARPORT
30.5
F
30'X80' ACCESS ESMT.
RECORDED IN HOOK 2034 PACE 3613
33' SECTION LINE ESMT.
_
20' T.& E. ESMT,
10' UTILITY ESMT. 12' TRAIL ESMT.
77
30.00
N89`59'56"W 200.50
8
GRAPHIC SCALE. i Inch = 40 Feel
20 0 20 40 so
Recet of As—built 12-18-13
FOR: TROY DAVIS HOMES
FORBES & ASSOCIATES, INC.
P.O. BOX 232293
Anchorage, Alaska 99.523
(907) 227-5881
10-13-13 1" = 40'
Lot A.
Block
Grid As -Built Survey
NW 1261 2130201 DENALI VILE
Drawn by Field Book SUBDIVISION
CEF 243
I hereby certify that the property described hereon has been surveyed
by me, or at my direction, and that the improvements situated thereon
are within the property lines and do not overlap or encroach on the
property lyingadjacent thereto unless otherwise shown. That no
improvements on the property lying adjacent thereto encroach on the
premises in question and that there are no roadways, transmission
lines or other easements on said property except as shown.
It is the responsibility of the owner or builder, prior to construction,
to verify proposed building grade relative to finish grade and utility
connections and todetermine the existence of any easements, covenants,
or restrictions which do not appear on the recorded subdivision plat.
Listed distances prevail over sealing.
Reproduction may cause distortion.
1
CHARLES E. FORBES
". LS -7326
12-18-13 �
n