HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 8H LT 18ARabbit Creek
View & Heights
Block 8H
Lot 18A
#020-571-43
• -'-� Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904 s T E T Y
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 020-571-43
1. GENERAL INFORMATION
Expiration Date:
Complete legal description Rabbit creek view & Heights Block 8H, Lot 18A___
Location (site address) 8111 Robert Dr. Anchorage, AK
Current Property owner(s) Robert Boothroyd & Gabriela Olsen Day phone
Mailing address
Real Estate Agent
8111 Robert Dr. Anchorage, AK
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
TYPE OF WASTEWATER DISPOSAL:
4. TYPE OF WATER SUPPLY:
Individual
Individual Well
®
Holding Tank
❑
Individual Water Storage
❑
Community
❑
Community Class _ Well
❑
Public Sewer
❑
Public Water System
❑
WaiverNariance request for:
Received by: _ _ _ _ Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee
Date of Payment
Receipt Number 0�.5�5'F5
COSA # Os C 2 113.6/
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
Distance:
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING INC. _ Phone 696-6111 _
Address 20441_ PTARMIGAN_ BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS _ Date i%Z�J
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition
of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface
conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate
during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can ArcTerra guarantee that no unseen ®r1 M1
encroachments, deficiencies or discrepancies exist. jt`,
Ae J
6. DSD SIGNATURE
fSystem #1 Approved for bedrooms.
System #2 Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following st*
OF
_ _ _ __ ._ _ _._._.__�•-'� SITE- ��--
v4 WP RP
FAfT S,E9,illl�ll
By �� `� Original Certificate Date: T b d
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist --- - _____ _ Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other--,--,--
COSA
ther___._
COSA blue sheet -10-10-12 doc
COSA Checklist
Legal Description: Rabbit Creek View & Heights block 8H Lot 18A Parcel ID:
If more than 7 septic system on lot: COSA Checklist # of Structure served by this system _
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 8/2/09
Total depth 246 ft
Cased to 177 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA 6/8/21
Static water level at beginning of test 27 ft.
Comments
B. TANK DATA
Age of tank(s) 13 years
Tank type/material Septic/Steel
Measured operating fluid level in septic tank 49"
U Standpipes/foundation cleanout per record drawing
Date of pumping 6/15/21
D. ABSORPTION FIELD DATA
Which system tested (date installed) I1 ;ils
E ALL standpipes present per record drawing
Total measured depth from grade 3.8 ft (max)
Measured depth to pipe invert from grade 3 ft (min)
❑ N/A — pressurized field
�■ Monitor tubes go to bottom of effective. If not, state
depth into effective
Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
020-571-43
Well production at time of test 4.3 gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes No
0 Coliform bacteria is Negative
Nitrate 0.658 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ND ug/L ❑ Arsenic less than MRL (ND)
Collected by Arcterra Consulting
Date of Sample 6/7/21
FT STATION
❑ Requ aintenance completed
Age of lift station years
Lift station material
Comments
Adequacy test date 6/8/21
Results p✓ Pass For 3 bedrooms
Fluid depth prior to test 0 in
Water added 450 gal
New depth 0 in
Elapsed time 10 min
Final fluid depth 0 in
Absorption rate 450+ gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot> 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
0 Yes
if No
ft
0 Yes
if No ft
Neighboring Tank > 100' 0 Yes
if No
ft
Private Sewer/Septic Line > 25'2] Yes
if No ft
Absorption Field on Lot > 100' 0 Yes
if No
ft
Holding Tank > 100' ® Yes
if No ft
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' ® Yes
if No ft
® Yes
if No
ft
ft
If septic tank is under driveway
comment below
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ®. Yes
if No
ft
0 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100'
® Yes if No ft
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
® Yes
Absorption Field > 5'
® Yes
if No
ft
Private Wells > 100'
0 Yes if No ft
Water Main > 10'
® Yes
if No
ft
Community Wells > 200'
0 Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells > 100' 0 Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No ft
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
/ certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
7 8 9 70
Inici
ge
On -Site W a d an�ro r rn 400
03
0 71, Z:
Aj
Certificate0 Approval
of
6 2 L
Parcel I.D. 020-571-43 Expiration Date:
1. GENERAL INFORMATION:
Complete legal description Rabbit Creek View & Heights; Block 8H, Lot 18A
Location (site address) 8111 Robert Drive *Anchorage, AK 99516
Current Property owner(s) Robert & Michelle Anderson Day phone 907-952-9395
Mailing address 8111 Robert Drive *Anchorage, AK 99516
Real Estate Agent Day phone
2. TYPE OF DWELLING:
Z Single Family (w/wo ADU)
1771 Duplex
F-1 Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
z
Individual
z
Individual Water Storage
EJ
Holding Tank
E71
Community Class Well
0
Community
❑
Public Water System
El
Public Sewer
❑
WaiverNariance request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
I
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 t
Engineer's Printed Name: Jeffrey A. Garness Date:
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
6. DSD SIGNATURE
System #1 Approved for
System #2 Approved for
Disapproved
Conditional approval for
By:
O F
.. . . ........... ...
J f. A. me
CE
c
. q G� � • cOG
\ o
vn� %ofess" <'�o
#AECC884
3 bedrooms OF
bedrooms
J pal -SITE �
bedrooms, with the follow tips N0TiER• AND
o \NASTEWATER 0
11)))))111
Original Certificate Date: ? I's 1 /
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineers work.
7. ATTACHMENTS:
COSA Checklist Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet_1010-12.doc
Legal Description: Rabbit Creek Heights & View; Block 8H, Lot 18A Parcel ID: 020-571-43
If more than 1 septic system on lot: COSA Checklist # of Structure served by this system
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 8/2/09
Total depth 230 ft
Cased to 177 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 9/5/19
Static water level at beginning of test 33.1 ft
Comments
B. TANK DATA
Age of tank(s) 11 years
Tank type/material septidmeel
Measured operating fluid level in septic tank
❑ Standpipes/foundation cleanout per record drawing
Date of pumping 9/8/18
Well production at time of test 3+ gPm
Water storage tank volume n/a gallons
Well disinfected for coliform test? ❑ Yes FOR No
❑ Coliform bacteria is Negative
Nitrate mg/L EZ"Nitrate less than MRL (ND)
Arsenic ug/L [2'*Arsenic less than MRL (ND)
Collected by GEG,Ltd.
Date of Sample 8127/19
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments
p
D. ABSORPTION FIELD DATA
V
Which system tested (date installed) 11 (5l s
Adequacy test date 9/5/19
-2
❑ALL standpipes present per record drawing
Results ❑✓ Pass For 3 bedrooms
Total measured depth from grade 3.8 ft (max)
Fluid depth prior to test 0 in
Measured depth to pipe invert from grade 2.4+ ft (min)
Water added 605 gal
F-1 N/A — pressurized field
New depth 3 in
:.
❑ Monitor tubes go to bottom of effective. If not, state
Elapsed time 30 min
depth into effective
❑ Code -required soil cover over field
Final fluid depth 0 in
❑ System presoaked
Absorption rate 450+ gpd
(Required if vacant for greater than 30 days prior to
Any rejuvenation treatment (past 12 months)
date of test)
Gallons introduced 2,027 gallons
_
If yes, enter date
Comments/Deficiencies: 'Pre-soaked on 914119- North Trench tested only- South trench at time of inspection was dry
COSA Checklist yellow sheet
WS
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
❑ Yes
if No *5+
Community Sewer Manhole/Cleanout > 100'
0 Yes
if No
ft
FvJ Yes
if No ft
Neighboring Tank > 100' 0 Yes
if No
ft
Private Sewer/Septic Line > 25'E] Yes
if No ft
Absorption Field on Lot > 100' 0 Yes
if No
ft
Holding Tank > 100' 0 Yes
if No ft
Neighboring Absorption Fields > 100'
Water Service Line > 10'
Yes
Animal Containment > 50' El Yes
if No ft
F/I Yes
if No
ft
Manure/Animal Excreta Storage > 100'
—❑✓
Community Sewer Main > 75' 0 Yes
if No
ft
Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
❑ Yes
if No *5+
ft
Surface Water > 100' U Yes if No ft
Property Line > 5'
0 Yes
if No
ft
Wells on Adjacent Lots: W % ;u coveLA-Ir
Absorption Field > 5'
Yes
if No
ft
Private Wells > 100' C� Z Yes if No ** ft
Water Main > 10'
Q Yes
if No
ft
Community Wells > 200' E✓ Yes if No ft
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Q Yes if No ft If absorption field is under driveway comment below
Property Line > 10' Q Yes if No ft Wells on Adjacent Lots:�w Cav�e-
Water Main > 10'❑ Yes if No ft Private Wells > 100' [TYes if No ** ft
Water Service Line, > 10' Yes if No ft Community Wells > 200' 0 Yes if No ft
Surface Water >,100'. Q Yes if No ft
F. ENGINEER'S COMMENTS
*Met code at time of installation
"Rabbit Creek View & Heights; Block 8H, Lots 2A, 23A, & 24A have structures on them but no
MOA well/septic documentation. Did not confirm separation distance to wells (if they exist) on these lots.
G. ENGINEER'S CERTIFICATION
1 certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
#AECC884
r