Certificate of On -Site Systems Approval
Parcel I.D. 015-484-15
1. GENERAL INFORMATION:
Complete legal description T12N, R3W, Sec 15, Lot 138
Expiration Date: ':1 )e C J , 0"? 0 f
Location (site address) 4721 E. 104th Avenue *Anchorage, AK 99507
Current Property owner(s) Ken & Heidi Schulz Day phone 502-387-7596
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
6
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual
❑
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
Public Water System
❑
Public Sewer
❑
WaiverNariance request for:
Distance:
Received by:
Date:
COSA to be released to the engineer, unless otherwise
requested by the
engineer.
COSA Fee $ J�SD Waiver Fee $
Date of Payment g 2(,o IN 44 Date of Payment
Receipt Number 0'b < < G Receipt Number
COSA # 05C,11 19 -DR -1 Waiver #
0
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineerinq Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness
19
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
#AECC884
6. DSD/ SIGNATURE
J System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedro\m+>(tftK6yag stipulations:
� \Q �'
ON-SITE
WATER AND
--mEWATERo�
PROGRAM
By: -2
116-94)
3
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 10-10-12.doc
COSA Checklist
Legal Description: T12N, R3W, Sec15, Lot 138
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑E Well log is filed with Onsite (or attached)
Date drilled 6/25/06
Total depth 266 ft
Cased to 266 ft
❑ Sanitary seal is functioning correctly
❑� Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 817/19
Static water level at beginning of test 195.5 ft
Comments
B. TANK DATA
Age of tank(s) _
Tank type/material
Measured operatin
❑ Stand ' /foul
e of pumping _
years
E{uitTlevel in septic tank
ation cleanout per record drawing
D. ABSORPTION FIELD DATA
Which system tested (date installed)
❑ ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for er than 30 days prior to
date of test)
Gallons ' oduced gallons
Co nts/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 015-484-15
Structure served by this system
Well production at time of test 6.0+ gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes ❑■ Nc
❑■ Coliform bacteria is Negative
Nitrate mg/L [% Nitrate less than MRL (ND)
Arsenic ug/L J)J Arsenic less than MRL (ND)
Collected by GEG
Date of Sample 8/12/19
C. LIFT STATION
❑ Required maintenance completed
Age of lift station yea
Lift station material
Comment
Adequacy test date
Results ❑ Pass For rooms
Fluid depth prior to to in
Water adde gal
N epth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
Eli
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
❑ Yes
if No
Community Sewer Manhole/Cleanout > 100'
P Yes
if No
ft
FV1 Yes
if No
Neighboring Tank > 100' 121 Yes
if No
ft
Private Sewer/Septic Line > 25' 0 Yes
if No
Absorption Field on Lot > 100' ❑v Yes
if No
ft
Holding Tank > 100' ❑✓ Yes
if No
Neighboring Absorption Fields > 100'
W rvice Line>0'
❑ Yes
Animal Containment > 50' ❑✓ Yes
if No
❑r Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' E] Yes
if No
ft
❑✓ Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
❑ Yes
if No
ft
Surface Water > 100' es if No "
Property Line > 5'
❑ Yes
if No
ft
Wells o • ent Lots:
Absorption Field > 5'
❑ Yes
if No
Private Wells > 100' ❑ Yes if No.
Water Main > 10'
Yes
if No
ft
Community Wells > 200' E] Yes if No.
W rvice Line>0'
❑ Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
❑ Yes
if No
ft
If absorption field is under drivewa n I
Property Line > 10'
❑ Yes
if No
ft
Wells on A • ots:
Water Main > 10'
❑ Yes
if No
Private Wells > 100' ❑ Yes if No
Water Service Line > 10'
es
if No
ft
Community Wells > 200' ❑ Yes if No
ater > 100'
❑ Yes
if No
ft
F. ENGINEER'S COMMENTS
No evaluation or testing was performed on the community septic system.
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
�.
Qp •"Je
r A. Gorne
-)3
VQO 9, '•
s
E 79
•mac O
e � o
Profess -to °aa
#AECC884
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
Jeff Garness
From: David Harper <dlharper2@gmail.com>
Sent: Wednesday, August 21, 2019 5:54 PM
To: Jeff Garness
Subject: 4721 E 104th Ave
Jeff, the well seal at the above location has been brought up to current MOA code requirements.
David Harper
Aarow Pump & Well Service, LLC
Sent from my iPhone
LOT 136A I Windowwell
�U
00
m O
C'7 O co O Well
�— CV T
O O
C`7 co
Mo
00
0 0
C:) 0 to
Z Z 0
O
LCA
LOT 117 S89058'31 "E 1330.18 (C)
EAST 329.87 (131-
280.18
BL
280.18 (C)
280.32 (M)
M 8 e S
:Flame
Ret. wall (lyp)
LOT 116
LOT 138
Septic vent (typ)
U
Do
0
/ \ Ln
0
O
e
Ge�cae��e�
J�
2.3 OH
Gravel dfiveWaY
N 280.18 (C)
S89058'31 "E 330.18 (P 2002-178
EAST 329.87 (BLM)
There exists an AGREEMENT TO PROVIDE ACCESS
recorded 6-28-2006, Serial No. 2006-042848-0
LOT 139
0
0
o Road Reservation
LO
CE E. 104th Avenue
EAST 329.87 (BLM)
LEGEND S89058'25"E 329.89 (C)
(BLM) Record per BLM survey dated 1-27-1965
(R) Record per Plat No. 2002-178 (BLM Lot 136A)
(C) Computed per Plat No. 2002-278
Note: There exists a variance from AMC 21.40-080.G3
in the R-6 District to allow both house and deck to
encroach into the 50' rear yard setback recorded
2-25-10, Serial No. 2010-008852-0.
as
o
D
SCALE: 1"= �,
EASEMENTS OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON
UNLESS OTHERWISE NOTED.
FB 19-3, pq 70-73
�.N\\\%,1
OF • A4,1 100
+I
49th -7
00
/ iza6eth L Walatke .
10
�� siF • 8036 - LS
7839D
r
c
0
.8I
U
. .
Oca
r
0
Ilf
pco
Z
O
CO m
I
o
U
U
~o C)
w
0
0
L6 I
r-
Z
0
Z Z
Q
— —
50.00
0
0
0
Ln
AS -BUILT NO CORNERS SET THIS DATE
I hereby certify that I have performed a Mortgagee's inspection
of the follov"ng described property. BLM LOT 138.
SECTION 15, T12N. R2W. S. M. AK
Anchorage Recording District Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission fines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 1st dayof AUGUST .2019.
FRED WALATKA & ASSOCIATES, LLC.
BE907-248-1666 Engineers and Surveyors