HomeMy WebLinkAboutSOUTHPOINTE BLK 3 LT 2outhpointe Block 3 Lot 2 #020-311-60 MOA has confirmed that the onsite systems have not been installed. Permit Number: #SW080204 Date of Issue: 9-23-08 Parcel Identification Number: 020-311-60 Date Started: 10-10-08 Date Completed: 10-12-08 Is well located at approved permit location? M Yes R No Legal Description: Southpointe Block 3 Lot 2 Property Owner Name & Address: Ross Biefing PO Box 902017 Lake Mary, Florida 32795 Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) From To Method of Drilling Z air rotary ❑cable tool Casing type: steel stick-up 0 3 Wall Thickness: .025 inches shot Rock 3 9 Diameter: 6 inches Depth: 54 feet bedrock 9 526 Liner Type: Diameter: inches Depth: _ feet Casing stickup above ground: 3 feet Static water level (from ground level): 71 feet Pumping level: feet after 24 hours pumping 3 gpm Recovery Rate: 3 gpm Method of Testknii: airlift Well Intake Opening Type: ❑ Open End Z Open Hole El Screened Start feet Stopped feet El Perforations Start feet Stopped feet Grout Type: bentonite chips Volume: 7 Depth: Start 3 feet Stopped 53 feet Pump: Intake Depth feet Pump size lip Brand Name Well Disinfected Upon Completion? Z Yes F-1 No Method of Disinfection: Comments: Well Driller: Alpine Drilling & Enterprises P.O. Box 110496 Anchorage, AK 99511-0496 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property owner or the well driller shall provide a well log to the Development Services Department within 60 days of completion. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water B Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM ) WATER SUPPLY PERMIT Initial Permit Number: SW080204 Legal Description: SOUTHPOINTE BLOCK 3 LOT 2 Design Engineer: 0014 ANDERSON ENGINEERING Owner Name: ROSS BIELING Owner Address: PO BOX 902017 LAKE MARY, FL 32795 - Date Issued: Sep 23, 2008 Expiration Date: Sep 23, 2009 Parcel ID: 020-311-60 Site Address: NHN SOUTHPOINTE RIDGE DRIVE Lot Size: 108453 SQ. FT. Total Bedrooms: 7 Permit Bedrooms: 7 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By. Date: z)3 n B / Date: `7 /w Municipality of Anchorage Development Services Department Building Safety Division _ On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I. D. 020-311-60 Property owner(S) Ross Bieling Day phone 272-2446 Mailing address P.O. Box 952017 Lake Mary, FL Zip Code 32795 Site address Southpointe Ridge Drive Anchorage, AK Zip Code 99516 Legal description (Sub'd., Block & Lot) Lot 2, Block 3, SouthpointeSubdivision Legal description (Township, Range & Section) Lot Size 108,453 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field El Septic Tank [] Holding Tank ❑ Privy ❑ Private Well 0 Water Storage ❑ Number of Bedrooms Seven (7) THIS APPLICATION IS AN: Initial 0 Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. N (Signature of property owner or authorized agent) Permit/RushFees: U ' 1'YZ) Date of Payment: Q I Uo la Receipt Number. bq qa3 (Rev. 11105) Waiver Fees: Date of Payment: Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX September 15, 2008 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 3, Southpointe Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Block 3, Southpointe Subdivision intends to construct a seven - bedroom home on the lot. We are therefore requesting a permit be issued for construction of a well and septic system to serve the new home. The size of the septic system and the proximity of bedrock to the ground surface limit the available area for the sewage disposal system and make it difficult to place a conventional septic system. We have therefore decided to place an Advantex Treatment System on the lot to provide the most effective treatment of the septic effluent prior to discharge into the surrounding soil strata. The location of the absorption system is shown on the attached Site Plan. Drainage patterns are also shown on the plan and will not be modified as a result of the proposed construction. The test holes placed on this lot revealed silty sand with gravel soils with some sand (SM/SP) underlain by bedrock. The percolation rate in the materials encountered in the area near the new system was 1 to 5 minutes per inch. No groundwater was found but bedrock was encountered at 6'-7' below the surface. Our design provides for the bottom of the absorption trench to be as shallow as possible. We are therefore proposing to place a seven -bedroom Advantex Treatment System. The absorption bed will be 30' long x 15' wide. The distribution line in the trench will be placed at the existing ground level. The organic layer will be removed and replaced with coarse sand. 3' of fill will be placed above the bed and 4' over the septic tank to meet Municipal Code and prevent freezing. Insulation with 2' of fill may be placed instead of the total 3' of cover. The ground surface of the lot slopes at 5% to the southeast near the location of the primary absorption bed site. A substantial amount of fill material has recently been added to the lot, but none in the area of the absorption beds. The beds will be Lot 2, Block 3, Southpointe Page Two constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from any surface water and 100' from the well proposed for this lot. No conflicts exist between the proposed well and septic system and those in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, y 4 cd,41 Michael E. Anderson, P.E. Attachments S � 101.65 II �\ N'934'ps„ \ < ? o� ��� '5. D\ w \ C) O o m \ D -I N n W 39 —iCY) 2 A m (OLn O ^ m \ 0 W --f \ 0 o ma N V \ o @N N ~ \ y � Obi '06•\\� cNJ� \ \ \ w \ \ 1 � f 168.69 D O r-. I z o $g -q D ti l g Ro• z / S AAS �Ro. 6'O 55t / ?9F � � O / z —1 \ \ \ SSS \ Jr. SS\ \ \ \ / I \ so \ m / ~ / \ F - 3m w I 00 c0 I m 0 / o � Cocrl o I V I \ / / D C) I o \ / / D Oo -' / z I it -� �� \�_3AI80 3041', /� Existing Ground LOT 2, BLOCK 3, SOUTHPOINTE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 7 Bedroom Home Raised Bed System Perc. Rate: 1-5 Min./inch 7 Bedroom Advantex Treatment System Application Rate: 4 GPD/SF 3,500 Gallon Tank w/2 AX20 Pods Raised Bed Absorption System 7 Bedrooms X 150 GPD/4 GPD/SF = 262.5 SF Absorption Area 262.5 SF/15 SF (Width) = 17.5 LF Bed Length THEREFORE: Construct an Oversized Raised Bed 30' Long x 15' Wide as Shown Below. Place Distribution Piping at Original Ground Surface. Remove Organics and Fill and Place Coarse Sand to Provide 4' Separation From Groundwater. Place Insulation and 2' of Cover Over Bed or Mound Over Bed Minimum of 3'. Place 4' of Fill Over Tank. Top 6" of Mound Must Be Topsoiled and Vegetated to Prevent Erosion. Natural Backfill 2" Insulation & 2' Cover •5, O O O ,5, Drainfield Rock 4" PVC Holes Down 1' or Coarse Sand (See Specification) As Required As Required for Levelling And Replacement of Fill and Organics. In Situ GM Soil 2.5' 5.0' 5.0' 2.5' TYPICAL BED SECTION (NO SCALE) NOTE: Grade Area Surrounding Bed to Drain Away. i Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Welts in the Area. Minimum 100' Separation From Surface Water or Streams. . Minimum 10' Separation From Water Service Line. Existing Performed For. Legal Description: 1 4 9 10 11 12 13 Municipality of Anchorage Department of Health & Humari Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Testhole Number 24 Run Elevation lttom Hole Was Groundwater Encountered? No If Yes, What Depth? Depth to Water After Monitoring None Date: 9/7/03 L Comments: e Performed: 11/1/99 Block 3 SII `ti:.•Q. I4 15 � �' •'� y .•........so AVCNML L ANDSWN : i CE -4381 17��`• •• ;-.4�; . 1 �p.7-it-Op .�-?�'r ��IFo 18 pQOF • St0 ��• • lei 1' I I Comments: e Performed: 11/1/99 Block 3 SII ®I' �ii� 1 � •' - •. /. ' • lei 1' I I � i' � ' // , / I i i \• \� 24 I 1 l 4t1. . 0 � 1 'il ill •��` \, Q Perc. Rate: 1.2 MIn/Inch Perc. Hole Diameter. 6. Test Run Between: T& 4' Performed By: TLK I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9/7/2003 z 4 5 6 7 8 9 10 11 17 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/ON-SITE WATER AND WASTEWATER PROGRAM 4700 SOUTH 13RAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: John Berqqren LEGAL DESCRIPTION: TEST HOLE # 23-A OG/OL Silty Sand with Some Gravel SM/SP 1. Bed Rock 7' WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: Mu._ DATE: DATE PERFORMED: 5/1/2003 No S NET TIME L NET DROP 0 11:42 None E 5/15/2003 1152 —fDTTS72003 Dry READING DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP Start 5/3 11:42 1.75' 1 1152 10 Dry 975' Recharge 11:53 1.63' 2 1203. 10 Dry 9 87' Recharge 1113 1.75' 3 1223 10 Dry 9.75' PERC RATE: .I MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN—LO—FT. AND 4 0 T. COMMENTS: Test Hole Pre Soaked Prior to Test. TEST PERFORMED BY: AH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 9/7/2003 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0850 SOILS LOG - PERCOLATION TEST Performed For. Legal Description: Testhole Number 23 Run Elevation C Hole e' 11 12 1 � II 1 �r 1 \1 Was Groundwater Encountered? No If Yes, What Depth? Depth to Water After Monitoring None Date: .5/15/03 Air *�1 74� 97nt fl� A* i 15 •Ctt/�i.�N4e..�......•`^-sSC0, �MICFIAEI [. ANDERSON v 18 0j`frf:• 4-/43 1171 c.?�.. q ; P -0 0 Comments: Date Performed: 2, Block 3 i i SITE PLAN /�/ ' R Perc. Rate: <1 Min/inch Perc. Hole Diameter. 8" Test Run Between: T& 4' Performed By: JDN I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9/7/2003 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BLOCK 3, SOUTHPOINTE SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new Seven Bedroom Advantex Treatment System including a 3,500 gallon tank with 2 AX -20 -Mode 1 a 40x94 Pods to serve the new home on the lot. System will be placed at the location shown on the Site Plan. The new septic system also includes the construction of a new 30' long X 15' wide absorption bed at the location also shown on the Site Plan and at the configuration shown. The distribution line in the bed will be placed at the existing ground surface. Organic material will be removed and replaced with coarse sand meeting the requirements outlined in the Sand Gradation Section of these specifications or with septic rock. The new system must be placed a minimum of 100' from the proposed well on the lot and those on adjacent lots and 100' from any surface water located near or on the lot. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines and easements. A final certified surveyor as built must be submitted showing the location of the septic system. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department Building Safety Division On Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On Site Water and Wastewater Program before beginning system installation. SEPTIC TANK INSTALLATION The Advantex Treatment System must be installed in conformance with specifications and regulations furnished by the manufacturer, Anchorage Tank and Orenco Systems Incorporated. No variances Lot 2, Block 3, Southpointe September 15, 2008 Page 2 of 4 from the manufacturer's specifications will be allowed without permission from the manufacturer and Municipal representatives. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. Lot 2, Block 3, Southpointe September 15, 2008 Page 3 of 4 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. SAND GRADATION: 1. Sand used to level the new absorption bed must have the following gradation: 50% Passed the No. 4 Sieve 2% Passed the No. 100 Sieve 1% Passed the No. 200 Sieve 2. The sand source must be approved prior to use. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. Lot 2, Block 3, Southpointe September 15, 2008 Page 4 of 4 The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Set.16. 20VI 12:5Er'.V anderson engineering 8).6145 P. 2 ADVANCED WASTEWATER TREATMENT SYSTEM 1tLUNTENANCE AND REPAIR AGREE.NIENT b1EMORA\`DUM OF UNDERSTANDING BETWEEN ,rI Y OF ANCMRORAGE A. e %7 a, THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this a6 /2Dayof_! t r.6eR of2oo$byandbetween 20st 61CW44 herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: I. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater A DV ANrex Ta cA^1NVJ1— Treatment System (AWWTS), described as S)( sroy1 located at 1drZ edr- 3 SO 'POIN E Anchorage,Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an AWWTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AW WTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC")15.65. B. Certificate of On -She Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. See.'6. 2005 12:5VV anderson ergir,eering 1a. 6143 F. 3 These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On -Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all the requirements of this agreement, the conditions of Operating permit, the requirements of the On -Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. fee. Owner shall pay to Municipality an annual fee of AJ O.J a✓' (S-0 .00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. JLrM. The term of this Memorandum of Understanding shall be for the life of the AN6VTS. Seo.16. 2003 12:59'rV aneerson engineering Ro.6145 P. 4 The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations, Installation and Removal of Additional Equipment. Owneragrees not to make any alterations, removal of parts or additions to the AWRTS without a Construction Permit from the Municipality. 6. Maintenance ond Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain A"TS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of mmaain�tenance and repair contained in the Owner's AWWTS Operating Permlt is: la C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. Se, -16. 2003 12:59PY anderson engineering 83.6145 P. 5 D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AWV67S upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for AW WTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Zonwaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. AMeLdment. A. This Memorandum of Understanding shall only be amended, modified or changed by a waiting, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Sec. 16. 2005 12:5S-4 anderson er.Eireerini N:. 6145 P. 1 Owner: Anchorage:rrchasin¢ Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions Of the Memorandum of Understanding. Date: �fo-c 4 � Se ti i 7. 0 8 STATE OF ALASKA THIRD JUDICIAL DISTRICT AIL'ATCIPALTTY: By: Title: Date: The foregoing instrument was acknowledged before me this I 'day of 20 0S by P.o S & j, NOTARY PUBLIC FOR My Commission expires: I1 /Li/ 12- 0TARY 'PUBLIC,:,