HomeMy WebLinkAboutROLLING HILLS VIEW ESTATES BLK 3 LT 8Rolling Hills View Estates Block 3 Lot 8 #050 - 322 - 24 Municipality of Anchorage -tel Development Services Department e. Building Safety Division On -Site Water and Wastewater Program r•�"' , �� _ 4700 Bragaw Street ,(� S A P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-322-24 COSA # Expiration Date: — _0C 1. GENERAL INFORMATION Complete legal description Rolling HIlls View Estates S/D Block 3 Lot 8 Location (site address) 19138 Upper Skyline Drive Current Property owner(s) Estate of Grif Griffis, Suzanne Stone Day phone 503.939.1645 Mailing address 18150 SW Rosa Road, #21, Beaverton OR 97007 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 0 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Engineering Services, LLC Phone 272-8218 Address P.O. Box 102954, Anchorage, AK 99510 Engineer's Printed Name Steven R. Pannone, P.E. Date 10/27/08 Engineers Comments: In conducting an adequacy lest, l attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system Thesc conditions arc outside the control of the evaluator or this system. All systems eventually fail an satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. PES can therefore not provide any warranty for future performance nor give any estimate of how long the system will continue to meet the operational requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for 0 bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: l/�/%r'/�j . /� Original Certificate Date:J (nev. ,,N`+) f i'c v S 7e,ln/�. %�� I—n'I f f m y sf G I10, 4-, .S //P// L, ��IiPi I / h - s- fe- P /L Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: l/�/%r'/�j . /� Original Certificate Date:J (nev. ,,N`+) T Municipality of Anchorage ' Development Services Department - Building Safety Division ' On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Rolling Hills Views Estates S/D Blk 3 L8 Parcel ID: 050-322-24 A. WELL DATA Well type Private If A, B, or C provide PWSID q Date completed 7/1/1968 Sanitary seal (Y/N) Yes Total depth 148 ft. Cased to 148 ft. FROM WELL LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 4.36 mg/L Well Log (Y/N) No Wires properly protected (Y/N) Yes Casing height (above ground) 36 in. AT INSPECTION 8/23/2008 17 ft. 2.2 g.p.m. Other bacteria 0 colonies/100 mL Arsenic: ND ug/I Date of sample: 8/23/2008 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material N/A Date installed Tank size gal. Number of Compartments _ Cleanouts (Y/N) Foundation cleanout (Y/N) _ Depression over tank (Y/N) High water alarm (Y/N) Date of pumping C. ABSORPTION FIELD DATA Date installed Length Pumper Soil rating (g.p.d./ft2 or ftp bdrm) ft. Width System type ft. Gravel below pipe ft. Total depth_ ft. Eff. absorption area fe Monitoring tube _ Depression over field Date of adequacy test Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date ... D. LIFT STATION Date Installed "Pump on" level at Size in gallons in. "Pump oft" level at _ in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot N/A Manhole/Access (Y/N) _ High water alarm level at Meets alarm & circuit requirements? On adjacent lots 100+ Absorption field on lot N/A On adjacent lots 100+ Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line 100+ Holding tank 75+ Animal containment areas 100+ Manure/animal excrete storage areas 100+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation N/A Property line Absorption field Water main Water service line Surface water Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property tine N/A Building foundation Water main Water Service line Surface water Driveway, parking/vehicle storage _ Curtain drain Wells on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven R. Pannone, P.E. Date 10/27/2008 COSA Fee $_ Date of Paymenl Receipt Number (Rev. 11105) Waiver Fee $ _ Date of Payment Receipt Number, .......... ... ... . »._.._ M %Sleven H. Ponncrejl L� �,n'+., No.CE 8149E(,� •_�. 1.4 ff �V4 711 W. few RAI6 r0+ we Min wow suRyEY mr.F1cArm P= PUM L MAX11AIE fT-NlT <«F rwTMll PWAOMM AS-NXT — MwM wNC'rwlt A64MT awoT r�ur .. .. .. .asp wM1•.} D? PLANS tc LOT Sl Is TME pE3Id1 �L.m TMS $up%% R TAM Prepered by Robert E. Johns, Jr. & 'Assoc. 1N a 60' R� LAI s.. ,rft� J IoM k BTI W"Y ft °' T o-24- 36 °'" by--- 412 S ,6 I 10 27—J3 °"� riMUS4 "•O• 0303 �+ yah Mrw: Lot 8 Floc:;: & Follilef .Iills Latrte.=, E SYMBOLS • slT RE9AR ' ' DR wAOO R`AfgNLt tMD �ccna woo IWx M0ft u__.T mC =HM M{ `L.r' AMMM [LEY. i.—.:+ Meru r c c.o.. REV ? go- M. TNtIw AwI'w0X"ATC LOCATION. o'Nir. SM WTT Ow P[S CT10NS 4AY Iw[YExr QO..G M'RO`/CMONT] r"C" OQMO DRN AMC LOCAL .O SLMdNTCN PLAT. ALL DIDTANOCS APIC "Conn UNLrat OTHEPVA NOT AN rA4 T .T I[ UIEO rOR CCMJTRUCTI(M OR "" 6JTAOLM*N0 WokommY OR f•CNCC LOOM c AIL O SCAAC!fON ONLY Aw0 AblNIE$ fMAMO{AL LIAlX7TT OL4T fm Im c=r OF TME xmwy.. ![YALE OMJt ECAUNC. REFRpptlOT!pN MLY CRUS' FTnd3 RI aOAIL. Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineer Anchorage, Alaska 99510 (907) 272 8218 WELL & SEPTIC SYSTEM ADEQUACY INVESTIGATION Legal: Rolling Hills View S/D, Block 3, Lot 8 Owner: Estate of Grif Griffis Residence: 19138 Upper Skyline Drive, Eagle River AK 99577 Septic System: Tank Size: 2600 g Absorption System Type: Cesspool (from records) Absorption System Size: Unknown Absorption Area: Unknown s.f. Installation Date: Unknown Soil Rating: sf/br Date of Pumping: 8/23/03 By: JR's Pumping Date of Investigation: 8/12/08 Test Procedure: The well is located in the southern portion of the lot over a steep bank. It was drilled in 1968. It has a total depth of 148 feet, based on information obtained from the State of Alaska DNR. The test conducted on this well in August of 2008 showed the well could produce water at a rate of 2.2 gallons per minute (132 Gallons per hour) with a drawdown of 74 feet. The well cap needs to be replaced or at least some work performed on it to create a sanitary seal. The wire to the cap does not seal inside the well cap (this is required under Municipality of Anchorage Regulations). The wire to the well is run over the ground in a plastic conduit and is bare wire (not in a conduit) were it enters the well cap. The well casing extends above the ground 36 inches, but has a depression around the base that needs to be filled in to provide positive drainage away from the well casing. We performed a water quality test at the time of the investigation. The water was analyzed by SGS Testing Lab for bacteria, nitrates and Arsenic. The results of the analysis show that there are no bacteria, no detectable Arsenic and 4.36 mg/1 of Nitrates. The allowable limits for Nitrates are 10 mg(l, Coliform Bacteria is zero counts, Other Bacteria is 10 counts. Arsenic is test for and monitored, there is no maximum limit for private wells at this time. Conclusion: Based on the test performed and information obtained from the Owner, the septic system is does not meet MoA Code. See previous letter describing the septic system. The water supply system appears to be operating adequately and meets the operation requirements of the MoA Code. The minimum water a well must produce is 150 gallons per bedroom per day. For a three bedroom house, that equates out to 0.4 gallons per minute. This well is able to produce the required water. The well does not meet the Code requirements: The well is required to have a sanitary seal, and the wires are required to be protected from the house through the sanitary seal. Upgrade Procedures & Anticipated Cost This water system needs to be upgraded to meet the Municipality of Anchorage (MOA) On-site well code. The following needs to be performed to accomplish this upgrade: Bury well wire a minimum of 18 inches below grade. Install sanitary seal on well cap. Obtain Certificates of On Site Approval for sale The well work will cost approximately $1, 500 to bring the well into compliance. Page 1 of 2 Page 2 of 2 In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. We can therefore not give any estimate of how long the system will continue to meet the operational requirements of the State or Municipality of Anchorage. Please call me if you have any further questions or require assistance in developing the upgrade design. 'SCE \OF .44,1 A 49th GV ; ............ STEVE" PANNONE ' p� •.. CE -8149 `� Steven R. Pannone, P.E. Civil Engineer September 9, 2008 WgIi , Mquini SCS ReEN 1084220001 Client Name Pannone Eng. Srv. Project Namem 19138 Upper Skyline Printed Date/time 08222008 11:35 Client Sample ID P 19138 Upper Skyline Collected Date rime 08/122008 8:30 Matrix Drinking Water Received Date/time 08/12/2008 9:30 Technical Director SlePhen C. Ede PWSID 0 Sample Remarks: 4500 NO3 - Total NitratesMitrites - MS outside of QC criteria (biased low). LCS is within QC limits. Parameter Results Metals by ICP/MS Arsenic ND 5.00 Waters Department Total Nitratc/Nitriie-N 4.36 0.100 Allowable Prep Analysis Units Method Container ID Limits Date Dare Init ug/L EP200.8 C (<IO) mg/L SM20450ONO3-F B (<IO) Microbiolovy Laboratory Colony Cowu 0 col/IOOmL Sh120 92228 Total Coliform 0 c01/IOOmL Sh1209222B Fecal Coliform 0 col/100mL SM209222D A (<200) A (<1) A (<1) 08/16/08 08/19/08 NRB 0821/08 JDZ 08/12/08 DLC 08/12/08 DLC 08/12/08 DLC ?XG-3194 U. S. DEPT, OT THE T••TERIOR MASTER CARD tiI ,feud.: Let lent Lo al•1 e.ST nrMr• Cll W: LUC Owner or aer• ..c 4- Qt-ntuvLt GEOLOGICAL SURVEY WATER RESOURCES DIVLSLON c 11: tier 1.1 b-.IP/aft( 01 J4 'J►zn0 1e !c v Pis• D.�•27.i,9we �f • 9 E t — a yOp � r.Do: i E't1e_t AVI— t. AJUW1 L, _Lk1p&2J_E 7w) I+�Iuai tt .f E,,.W .. I <r d"e r.h11: C. (C) red Cert. CityJ Cort er Co, (I u, State(WAdaae/. ato Dln (A) Mrm • (D) fq (r) (R), (I> <M (■) (q U) Us- of Air eoM, Sattlio3, Com, baster. rewq rlr., w�•ri (S) (n lsr, R.d, 1M, E S, 4c, Stwk, In•tit, Yeood, bpueasa, %•drag.. Daaal'/ /, D".3T) (b) ether, O[h.r .. Of (a) <n) .ai: Asad•, Drat a, Sauk, Rest "'s- ce.. airy•.(U / (t) (D) (Y) est {, 4<A.r e, Tut. UeodW , lcher ats, G•teoled. •e© DATA AVAI WLE: Yall daul l Fne, Y/L wo.S A❑ TT• Mrd. lab. 4u; Field aaelfer chat. � .S� 0w1, rq•r data; tYe•p Yrs /�_ r•❑ h•e. •ualnt: yes ►w•oate Inrentorr: w, led; am • Ap<rt cele HrdY ��• •e 070 Lon date: WELL-DESCRIt TION CARD I© SAME AS ON MASTES CAPD, • th velli mit • • ' Maae ft D p• Ith ea..d• rer C.atn aeeuuq ►lye ahs "IC)ouo piri! r. evil �e IMI (0) eN)n j if.. Acis., odT)rt.. ahirid, eui (0) .. a.. (P.N.) . �suu) . plt" M•M•--had (A) (3) (CI (0) (M) (J) _ •• r,llad: air b.rod, tab uS, hYd (I) (R) (T) other u .�- nt ]at tee, at, saeau, tnnehlnd, drlrin, erlve il) Dateret., preselen, r+[Ary, w.h• 1t r 111.4. i9�8 9 6 of Fw•s /nub reuln R Driller:7 w e D Lift naw it r, bebit. cent. ]at. ew)tlylt• e,.l i'lyl a,• M) (I) (L) © r•(1) (E) Dn/ (cant.) (sorb.) "Sa. Siston. tot. tuber{, [urb, other I�rr Mt , Shalloro • Uead•let Pe, 86eo11M, Mne, !s, viJ) Ju.Iran$,_LD star row Dwtr,e. MT .bore ft NIoe LSD. Alt. MI Alt. LS _ ��(Z•CL— ' / • Z • 6 eQ deeura< / Yater . sur<. - , _T2 a��u© ft .bee. .bow. Data below M: It k.lw LSD , e� u: u . i LJ ©et Yield: - . d.t.d 'E` e.t..rlwe it ^���Ateuraer• a •clod br.�tE'w�'.�A!{��.,•L���J� YA [• DATA! Ir ' / 1 SuI •• •' ' SL (( I�(� rP �E•I rate hlerldt Nerd. ls`CoWu<). aiRD t ■ IOE(2 .2!Dat w P. �) /20 a► N/o•.72- 4 O• rnbc i yr t Steve Pannone From: Steve Pannone [stevep@ak.net] Sent: Sunday, July 06, 2008 10:58 AM To: 'eggnogg@alaska.net' Subject: Estate of Griff Griffis Mr. Nogg, I was asked to write you by Ms Suzanne Stone, Mr. Griffis daughter, concerning the status of the water supply and wastewater disposal system at 19138 Upper Skyline Drive. I performed a site investigation on July 1, 2008. This e-mail will document my findings, recommendations for future actions. 1 researched the MoA on-site record for this property. The MoA does not have any information on the water or wastewater system on this property. Site Inspection I arrived on site and located the wastewater disposal system and water supply system. The wastewater system is located on the south side of the house. A single stand pipe was found. Ms Stone informed me that the original system failed in the mid 80's and a new system was installed at that time. The water well is located further south of the wastewater system, over the hill and adjacent to the road. The well was drilled in about 1968. 1 have not been able to find a well log as of this writing. Based on my investigation and pumping records from JR's Pumping, the wastewater system is a cesspool. cesspools have been illegal as a wastewater system since Statehood (1959) when the State of Alaska adopted the Uniform Plumbing Code. The Municipality of Anchorage requires that the transfer of title of houses with an individual water and or wastewater system obtain a Certificate of Onsite Approval (COSA) from the MoA On -Site Department. The water and wastewater system must be a legal system and tested to show that it is operating in accordance with the original design for the number of bedrooms it serves. This system is not able to obtain a COSA due to the wastewater system. Recommendations I see two options for this property. 1) Ms. Stone informed me that the house is basically a tear -down. If the house is demolished I would recommend the cesspool be abandoned and filled at the same time. The property can be sold as a vacant lot with a well. The engineering cost for this option is about $2500 to perform a well flow test, water analysis and obtaining a MoA COSA. 2) The other option is to upgrade the septic system to a legal system. The Engineering costs would include designing a new septic system, overseeing its installation, record drawings, well flow test, water analysis, and obtaining a COSA is about $5,00. The construction cost to install the new system and abandon the cesspool is about $15,000. If I can be of any further assistance concerning this matter please contact me at the numbers 7/6/2008 rabc t ui c below. Steven R. Pannone, P.E. Pannone Engineering Services, LLC (907) 272-8218 Phone (907) 272-8211 Fax 7/6/2008