Loading...
HomeMy WebLinkAboutSOUTHFORK NORTH TR DOnsite File AM Adft outhf%or wk SIM �mv Er w 1r1 Municipality of Anchorage Community Development Department Pogo I, o, 3 On -Site Water & Wastewater Program ` , At, y 1 1 - 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 995'19-6650 • http://www.n)uni.org/onsit�'I (�§0 tS-1904 Ofd -SITE WASTEWATER INSPECTION REPORT Permit Number. OSP 101 108 PID Number: 078-02-117 []X New ❑ Upgrade Name: vrAYrtE toes ABSORPTION FIELD ❑ Deep Trench ❑ Shollow Trench O Bed Cj Mound Address: i797 WEST RIVER DRIVE. EAGLE RIVER, AK 99577 ❑ Other Phone: No. or Bedrooms: Soil Rating: Total Depth he... original grade: (907) 301-3230 4 4.0 CPD/Sq. rt. 1.5 FEET (MAX.)rl. LEGAL. DESCRIPTIONDepth to pipe invert Item anginal grade; Crovel depth banaolh pipe: SEE DWG. rt. 0.54 rt Supdivision: Block: Lot: ria added abcve ariginol grade' Gravrl length SOUTHFORK NORTH - TRACT D SEE DWG. rt. 30 rt Township. Range: Section: Gravel -idlh• 9eds number of lines Distance act.reen lines. 5 rt. - - Ft SEPARATION DISTANCES Tala1 absorption area: 1 Number of trenr:hes 1 D.t bet—en bench.. _ To Se��c�',orption Lift Holding Public/Pfivole From Taieki Station Tank Sewcr Lincs �0 50. Ft.l r1 Well I 100+ 100+ 100'+ - 25'+ TANK ❑ Septic Z S.T.E.P. ❑Holding ❑ Other Manufacturer. Cepacity. Surface water) 100'+ 100'+ 100'+ - GREER TANK 1500 ca: Lot Line I 5'+ IMolerid; 10'+ 5'+ - N/A STEEL (DEEP BURIAL) NumL•er of Wmponmenle' 2 Foundation 5'+ 10'+ 5'+ - LIFT STATION! Curtain Drain NONE KNOWN Manufacturer: Capocily: GREER/OUANICS 1500 col. Remarks: THIS IS A OUANICS AEROCELE SYSTEM -Pump on- level at: TIMER Pump off' level at: TIMER Ffgh -aler olorm at 44•' • Pump ).lake & Moder P—Sc'-41T Elecincal Inspection, perlormec'. by RISING SON ELECTRIC PIPE MATERIAL -- SCH 40 F•louse to tank D3034 dTank nfiod PVC Installer GREEN GENERAL CONTRACTING Droinfield F810 CO/MT D3034 Inspector GEG, Ltd. BELCH MARK (Assumed elevation) 96.15 ;I Inspection Location and Description: Dotes: 1St 8/10/1D 2nd $/10/10 3rd 9/29/10 4th - BOTTOM OF SIDING AT POINT "B" ENGINrER'S.IEAL Community Development Department Approval OF ;IA Dote: � Conditional approval: Dote: S �r ��..• '7 411 711 i ; Q ... ..... . Vn tle�i�ey A�Gerness; UQ CohVe�'lOn o� A CA C'AT_r Qvaigt'cS 5 S%nl i1� Of�roVPd ZY�7,oZo-ev-E�t%cA 9' ' CE 7j 53 zf /r4�lf,V ly�li13 pct Approved:'—L LLQ : %. �J Dote: �� dP�o� ���t��QO�Q �r �1 In.pretian Rrpaft-1-1-12.aoc GARNESS ENGINEERING GROUP, Ltd AeroCefl'' ENGINEERING SALES CONSULTING Alasfva Atill,,orized Dealer June 30, 2020 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650 Anchorage, AK 99519-6650 (907) 343-7904 Ref: Southfork North S/D; Tract D (1797 {Nest River Drive, Anchorage, AK) Memo concerning converting CAT III AWWTS to CAT 11 AWWTS septic system To whom it may concern: The permitted septic system was installed on the referenced property on 8/10/2010 and was started up shortly after that. ARM Septic Services. LLC recently checked the monitoring tubes in the drainfield and found them to be dry. In order to simplify the overall operation and maintenance of the system, we are proposing that this unit be permanently configured as a CAT 11 system. Our justifications are as follows: The receiving soil has a percolation rate of 24 minutes per inch. Given this percolation rate, a 4.0 gpd/sq.ft. application rate is required for a Cat III system and a 2.0 gpd/sq.ft. application rate would be required for a Cat 11 system. There is 3.5+ feet of MOA filter sand below the drainrock in this drainfield. After the effluent passes through 2+ feet of MOA filter sand, the effluent should meet Cat III effluent quality levels. This system has 3.5+ feet of MOA filter sand above the native (insitu) soils. The residence on this property has a total of 4 bedrooms, so 150 sq./ft. of absorption area is required for CAT III effluent (600 gpd / 4.0). The existing 2010 drainfield has 150 sq./ft. of absorption area. In short, the drainfield meets the Cat III sizing requirements. At this time, we request that your department approve a CAT 11 configuration be used at the referenced property. Upon your concurrence, we will have ARM Septic Service, LLC, either leave the Jandy valve actuator in the discharge position; or have them completely remove the actuator. We w'll also ave them place a CAT II sticker on the control panel. "increlvA 1A , ess, F.E., M.S. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179' Fax: (907) 338-3246 * Website: www.garnessengineedng.com 143 S J 4,LVA WATEEl/�T Z� W___L Domestic - Commercial - Geothermal Phone 907-688-2759 www.suilivanwaterwells.com Well Log Permit Number: #SW 101108 Date of Issue 7/14/2010 Date Started: 7/22/2010 Date Completed: 7/22/2010 Property Description SOUTHFORK NORTH TRACT D Lot NONE Block NONE Parcel Identification Number: 07802117000 Is well located at approved permit location? IX Yes - No Section: Town: Range: Property Owner Name & Address: C & T CONSTRUCTION 11404 JESSIE MAE CIRCLE EAGLE RIVER, AK 99577 Borehole Data: Depth Method of Drilling [xJ air rotary ❑ cable tool Soil Type, Thickness & Water Strata From To Casing type: Casing Stickup 0 2 Wall thickness 0.25 inches Fill 2 5 Diameter 6 inches Total: 50 feet Overburden 5 7 Liner type: Diameter inches Depth: feet Yellow Clay & Gravel 7 46 2 Casing stick-up above ground: feet Static Water Level(from top of casing) 26 feet Yellow Sand & Gravel W/Clay 46 50 Pumping Level: feet after 1 hours pumping gpm Recovery Rate 7 gpm Method of Testing: Air Well Intake Opening Type IX I Open End [ ] Open Hole L] Screened Start feet Stopped feet Perforations Start feet Stopped feet Grout Type: Bentonite dry granular Volume: 50 Pounds Depth 44 Start 0 feet Stopped 44 feet Pump Intake Depth: feet Pump size: HP brand name - Well disinfected upon Completion? X !. Yes No Method of disinfection CHLORINE 50 PPM Comments: Water Sample Results: Arsenic: ug/1 Well Driller: -- Cole Sullivan Nitrates mg/l Sullivan Water Wells Total Coliform Bacteria colonies/100mL P.O. Box 670272 -_ Chugiak, AK 99567 Other bacteria: col/100mL (907) 688-2759 Attention: The property owner shall provide this log to DSD (onsite) and DNR within 30 days of completion. lq- I- CDT V! CY) CD I— I - Cy') co r - C) 0 (3) G) O x p A 0 (B O LL 0 cO C N \ n Q m \ Q z C' ) > N Q� cuN mil O z C� � d7 07 fD Q < Q y_ LD � U O N D L L Q LU LL Q 1-+••• p p m Z l LJ Im LOCN C 0 0 cO C N \ Q m \ Q z C' ) > N Q� cuN (3 Q O z O cu L W � d7 07 fD Q < Q Do 06 � � U J N LL LU LL Q 1-+••• p p m Z z CD O 1 N O C) OCD LL L f =Lij O U) a0 U CB i f` � U) 0 J J L 0 O Q N cn U of C O Q U � O O � O O -Q O O L O 0 E O > -o 0 a) Q � Q a) cu D L -U (n E > (1) O Q Q M N O O c a) � U x q. . L) 0 0 0 Q N Q� •� (3 Q O _Q O 0 O 1-+ V N O C .0— N O = ,5 N A � O C = 0 0 Q > to p An E 9 (un) o Q U O L- Q c a 0 o = m 0 3 Q ,N z Q >cu 0 O Qi L O Q Q cQ C Q N i N v � � O E X C)cuRf i L O d >, N > V/> 1 E -0 O o Q O >N O rL ^` _ ^2 0 •T O V`/ Q W Yom/ U W L.L V Q 4a c O N a 0 = � U c- ° CD CU N O A a 0- Q cn cu z W cnN OU °' cB = cu = Q F- O U O N O a (D x W 00 co 0 Q Q Qi Lo U) A, Ir— c co Oil V -r- d. �a I.L O U i ) V Z LLa �tf,( � L r ;~ N Q O .L I (D U O CO V _ � L Q Z � � Q) W 00 co 0 Q Q Qi Lo U) A, Ir— T (] a) LL > '-T Tb � V E V co O U) cu O U ) •O � L ;~ N UCL= +J L ❑ C U O cn O Q C\l El > C :3 > E U ❑ Q. U) C a- U m ❑ ❑ U a) � C � (D _0 Y LL �-- r V > C+7 ❑ .Q^ LCO O ❑ . cu Q cn (DL > ^' Q ❑ M _ U LU (D � a) m � ❑ O U cB m d 0 � � L Q. Q ❑ O J a) ❑ a >O >c6 U) C) O N R IL a O n a� 0 ❑ ❑ a c- LL O "_ r c ❑ m N d W O ❑Ln a. •> Q a) y.. Cf) U C/) cucn 0 O W v W W H a) N ca N ~ N Y Z o ca W LL O LL O M cn > m U c .c U) W W r O _0�.. o. a) U)L °' a O I— I— y Q Q > i5 a �> N M �f to cfl Wm 0 T (] a) LL > '-T Tb � V E V co O U) cu O 1.8 50 N/A 50 0.371 Forge Engineering 3/19/24 4/8/24 McDonald's 8/10/10 3.8 3.3 N/A N/A N/A 0 600 0 1440 0 > 600 6 0 6 Benjamin Schiller, P.E.3/19/24 (907) 522-7773 ARM Septic Services, LLC 7. Tasks for recirculating/discharge flows: - I Acceptable ❑ Unacceptable a. If applicable, Jandy valve functioning: ❑ Yes ❑ No N/A b. If applicable, Jandy Valve basin dry: ❑ Yes ❑ No -4 N/A c. Cleaned collection system in Aerocell unit: ❑ Yes ❑ No {6l Not Necessary d. Design recirculation ratio: 80 : 20 e. Actual recirculation ratio (Estimated): 6F0 8. Pump System: acceptable ❑Unacceptable a. Control panel in Auto: )JOY"es ❑ No b. Timer settings IFS Panel (No Override timer): ❑ Yes ON: Z^^- OFF: IZ -- Override —Override ON: Z !"-- Override OFF: — ❑ N/A c. Floats in correct placement: lKyes ❑ No d. Floats working properly: 24'es ❑ No e. High water alarm operational: EXes ❑ No f. High water alarm count: 7+ g. Pump Run Counts: h. Pump Run Time: _ ; t -A i. Float Error Counts:_ N/A b. Design Effective depth: the j. Total Override Counts: ir�j"^i/A _ k. Effluent Filter serviced: 2UYes ❑ No I. Tank lids secured after inspection: Nes ❑ No m. Weep hole functional: es ❑ No 9. Primary Tank ;jcceptable ❑Unacceptable d. Is there any surfacing effluent?: ❑ Yes a. Sludge and scum level checked: f V -Yes f t ❑ No b. Sludge/Scum levels: 1st: TJ 2nd:_ 3rd: c. Tank needs to be pumped: ❑ Yes 2�_No d. Water softener backwash discharging on system? ❑ Yes ❑ No e. How many people live on the system?: f. Tank lids/caps secured after inspection: AYes -1 No g. Last Date Tank pumped: vii 10. Drainfield: a. Type of Drainfield (circle one): Bed �5-wide Deep Trench b. Design Effective depth: the eet c. Checked Liquid Levels in Drainfiel Yes ❑ No MT#1 Liquid Level: Inches MT#2 Liquid Level: ---�� Inches MT#3 Liquid Level: Inches MT#4 Liquid Level: Inches d. Is there any surfacing effluent?: ❑ Yes No 17933 Old Glenn Highway *Chugiak, AK 99567 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com (PAGE 2 of 3) ARM Septic Services, LLC Maintenance Checklist: Advanced Treatment System Operational Checklist: Advanced Treatment System Legal Description: Street Address: Ljeo 14vtr- Service provided on: Date 10-17 - 2 Time: i0 4 Service provided by: Company: 4 Technician: (�fG✓1�� Date of last service: C,1 ^-; i " L 2.— By: ou Other: 1. Type of Aerocell Treatment System: Cat II -AeroCell Treatment System Cat III -AeroCell Treatment System 2. Conditions at media filter: VAcceptable ❑ Unacceptable a. Evaluate presence of odor within 10 It of perimeter of system: Olro—n6 ❑ Milo ❑ Stronnga ❑ Chemical ❑ Sour b. Source of odor, if present: N� 3. Manhole Risers and Pipe Caps: *cceptable ❑ Unacceptable a. Cover/s intact: 47,19 ❑ N.D. b. Method of securing cover: _S c. Insulation present on all lids? Yes ❑ No d. Any plumbing leaks or water intrusion: ❑ YesJg. e. Surface water/infiltration into components: ❑ Yes 1� No 4. Venting/Air supply: eVznceptable ❑ Unacceptable a. Air supply unit operating properly.es ElNo b. Venting appears operable. f�Yes 11 No 5. Media surface: Acceptable a. Biomat on surface. b. Uniform spray pattern. d. Ponding in/on media. e. Plugging/clogging of nozzles. f. Media appears to be settling. ❑ Unacceptable ❑ Yes )C -No Yes ❑ No Yes )�'No ❑ Yes ENo ❑ Yes Mo g. Appropriate maintenance performed. t* -Yes ❑ No h. Pest activity at surface. ❑ Yes<No 6. Effluent quality a. Effluent odor after passing through media filter:None b Effluent color after passing through media filter: Clear Mild ❑ Strong ❑ Brown ❑ Black L'2' —p W.t.t 3a.utta na 17933 Old Glenn Highway *Chugiak, AK 99567 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com (PAGE 1 of 3) ARM Septic Services, LLC" 11. Is the remote monitoring system functioning? (if no, describe in comments) ❑ Yes ❑ No a. Type of Monitoring system: b. Phone line working? ❑ Yes ❑ No ❑ N/A 12. Does this system receive an advisory notice/warning? (if so, describe in comments) ❑ Yes �Jo 13. Is the system in satisfactory condition/pass inspection? (if no, describe in comments) 1,. 'Yes ❑ No Other Comments: �Ct(( Service Provider: & �, f �-W Date: ` () I 17933 Old Glenn Hi ay Thugiak, AK 99567 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com (PAGE 3 of 3) MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of noa (\ of 20 Z u , by and between Dja(-`,-) , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Quantics located at (legal description) Southfork North Tr D 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). M-✓ Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, ``nni�ll repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Pagel of3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing (� guideluie %r' the construction, maintenance and repair of the Owner's AWWTS. QWWr agreesAomaintaiu„remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. SCYCEability• Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 F) LA O N k O LOT 1 BLOCK 6 LOT 2 BLOCK 6 LOT 4A PLAT #2019-107LOT 5 PLAT #86-205 LOT 3 BLOCK 5 S27° 3 0 ' 3 0 " E 4 6 3 . 8 2 N 6 1 ° 0 4 ' 4 7 " E 4 0 5 . 0 9 N14° 4 5 ' 1 2 " E 1 5 0 . 0 0 N19° 1 8 ' 0 3 " W 2 7 5 . 9 1 N2 3 ° 0 3 ' 5 3 " E 1 9 7 . 1 4 N6 2 ° 0 6 ' 5 4 " W 1 0 5 . 4 8 N00° 06' 45"W 131.80 S8 9 ° 5 8 ' 2 2 " E 1 4 9 . 0 0 S15° 00' 30"E 16.12 L =1 5 5 .9 5 R =7 1 4 .8 2 ℄ WE S T R I V E R DR I V E 3 0 . 0 ' 3 0 . 0 ' EDG E O F P A V E M E N T T E E E W S S SSSS SC 25' C R E E K M A I N T . E S M T . 65' U N D I S T U R B E D C R E E K E S M T . 100 ' S E P T I C S E T B A C K 2 0 ' D R A I N A G E E S M T . 10' T & E E S M T . 20' DRAINAGE ESMT. GRAVEL DRIVEWAY GRAVEL DRIVEWAY 1 0 0 ' W E L L R A D I U S 8 7 . 3 91.8 1 6 4 . 8 48.3 2 8 . 3 16.4 18.1 1 5 . 4 15. 4 1 0 . 7 13.8 1 0 . 7 Tract D Southfork North Subdivision 165,611 Sq. Ft. +/- 1797 West River Drive 3 Story Wood Frame House With Attached 2 Car Garage G E GRAVEL STAIRS S PREPARED BY: FRONTIER SURVEYS, LLC 650 W. 58th AVE. SUITE E, ANCHORAGE, AK 99518 907-460-1686 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING ID: SHEET 1 of 1 1.Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. Dimensions to property lines are plus/minus 0.1ft. 2.This document is created by Frontier Surveys for the purpose of an as-built survey for Morgan Michelsohn, only. 3.This document is based on Plat No. 88-12, Anchorage Recording District. General Notes DisclaimerLegend 1. This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible improvements and conditions at the time of the survey. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may reveal. It is the responsibility of the Owner to determine the existence of any easements, covenants, or restriction which do no appear on the record plat. Under no circumstances should this document be used for construction or for establishing a boundary or fence line. PS 1" = 50ft 10/13/2022 22-549KC Scale 1" = 50' AN AS-BUILT SURVEY OF TRACT D SOUTHFORK NORTH SUBDIVISION 1797 WEST RIVER DRIVE CONTAINING: 165,611 Sq. Ft. +/- (RECORD) RECORD PLAT: 88-12 Gas Meter Electric Meter/Outside Power Deck Septic Septic Tank M.H. E Elec. Pedestal Water Well Tel. Pedestal G E S T W Pierre M. Stragier No. L.S. - 9812 10/13/2022 R E GISTEREDPROFESSIO N A L L A N D S U RVEYOR SC MUNICIPALITY OF ANCHORAGE Development Services Department`, Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 078-021-17 Legal description Southfork North Tract D Site address 1797 West River Dr Eagle River Current property owner(s) Colleen Coadic Expiration Date: -2, 2 zj zo Z 3 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: M Original Certificate Date: 11/22/2022 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 ��1�UHMPAUTYOF o ;li — Development Services Department On -Site Water & Wastewater Section AHCHOR J° GE Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 078-021-17 Complete legal description Southfork North, Tract D Location (site address) 1797 West River Drive, Eagle River, AK Current property owner(s) Colleen Coadlc 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 907.929.2673 3. TYPE OF WATER SUPPLY: FE -1 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: A Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age J Z - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench X Wide Trench ❑ Seepage Pit Waiver request for: Distance: Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $-55-() Date of Payment 10 Z Is zao'-�_a COSA# 6SC2 2 /509 Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 COSA Checklist Legal Description: Southfork North Tr D Parcel ID: 078-021-17 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 7/22/10 Total depth 50 ft Cased to 50 ft ❑ Sanitary seal is functioning correctly 0 Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 9/27/22 Static water level at beginning of test 28 ft. Comments B. TANK DATA Measured operating fluid level in septic tank 48" Date of pumping 10/3/22 JR's ❑ Required maintenance completed, if AWWTS Comments: N/A D. ABSORPTION FIELD DATA Which system tested (date installed) 8/10/10 FOR ALL standpipes present per record drawing Total measured depth from grade 3.8 ft (max) Measured depth to pipe invert from grade 3.3 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced N/A gallons N/A date Any rejuvenation treatment (past 12 months) N/A If yes, enter date Comments/Deficienci COSA Checklist June 2022 Well production at time of test 1.8 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate 0.426 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L FO-1Arsenic less than MRL (ND) Collected by Forge Engineering Date 9/27/22 C. LIFT STATION LT ired maintenance completed Age of liftstation years Lift station material Comments: Adequacy test date 9/27/22 Results ❑ Pass Fluid depth prior to test 0 in Water added 600 gal New fluid depth 0 in Elapsed time 1440 min Final fluid depth 0 in Absorption rate ' 600 gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 6 in Effective depth used 0 in Effective depth remaining 6 in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' 0 Yes if No Community Sewer Manhole/Cleanout > 100' MM Yes if No ft Q Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' El Yes if No ft Holding Tank > 100' Q Yes if No ft Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' ❑ Yes if No ft 0 Yes if No ft ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Yes if No ft ❑ Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' n Yes if No ft Tank to Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' O Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells > 200' FE] Yes if No ft Water Service Line > 10' M Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Forge Engineering Engineer's Printed Name Benjamin Schiller, P.E. COSA Checklist—June 2022 Phone (907) 522-7773 Date 9/28/22 �- OFA/,c����� TM Benjaffo/Schiller 19F�, •, CE 12592 • c�`v�� k��PROFEWS 01 '® ������� ARM Septic Services, LLC Maintenance Checklist: Advanced Treatment System Operational Checklist: Advanced Treatment System Legal Description: ( Street Address: pc4l� "" ) Service provided on: Date: ' I�(�- 27 -Time: � Service provided by: Company: 4-111- Technician: e ('JMA y Date of last service: -N By:You Other 1. Type of Aerocell Treatment System: Cat II - AeroCell Treatment System Cat III -AeroCell Treatment System r-- 2. Conditions at media filter: acceptable ❑ Unacceptable a. Evaluate presence of odor within 10 ft of perimeter of system: ^'None ❑ Milo ❑ Strong ❑ Chemical ❑ Sour b. Source of odor, if present: & /W 3. Manhole Risers and Pipe Caps: 'Acceptable ❑ Unacceptable a. Cover/s intact: N- Yes ❑ No b. Method of securing cover: Cr J -C'/ c. Insulation present on all lids? S�-Yes ❑ No d. Any plumbing leaks or water intrusion: 'Yes ❑ No e. Surface water/infiltration into components: ❑ Yes No 4. Venbng/Air supply: acceptable ❑ rU�,n�acceptable a. Air supply unit operating properly. / � Yes L1 No b. Venting appears operable. !tel Yes ❑ No Enstrsearinp Water bosutta na wtCS (00104,'v^ -5 - 'T I . 5. Media surface: LVcceptable ❑ Unacceptable { `,1 C * a. Biomat on surface. *Yes ❑ No t �O x �� Q. (� 5c� �( � b. Uniform spray pattern. Yes 1�iN-No t 1' d. Ponding in,'on media. ❑Yes Y'No \,J �� 1 do S ` e. Plugging/clogging of nozzles. j Yes ElN f. Media appears to be settling. ❑ Yes Flo g. Appropriate maintenance performed. &Yes ❑ No h. Pest activity at surface. ❑ Yes Wlo 6. Effluent quality a. Effluent odor after passing through media filter: ,%one El Mild EJ Strong b. Effluent color after passing through media filter: Iklear ❑ Brown ❑ Black 17933 Old Glenn Highway `Chugiak, AK 99567 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com (PAGE 1 of 3) ARM Septic Services, LLC 7. Tasks for recirculating/discharge flows: L_l Acceptable ❑ Unacceptable a. If applicable, Jandy valve functioning: Lj Yes No k�-N/A b. If applicable, Jandy Valve basin dry: ❑ Yes ❑ No *-N/A c. Cleaned collection system in Aerocell unit: ❑ Yes ❑ No Not Necessary d. Design recirculation ratio: 80 : 20 e. Actual recirculation ratio (Estimated): ' 7 L" 8. Pump System: �Occeptable ❑Unacceptable a. Control panel in Auto: 5ryes ❑ No b. Timer settings IFS Panel (No Override timer): ❑ Yes ON: '-L �(Zr OFF: ( G � Override ON: Z`; 3O r, Override OFF: ❑ N/A QQ c. Floats in correct placement: Ye No'.tr+� 1v C� // c d. Floats workingproperly: d % P PerlY I�Yes ❑ No U" Lt e. High water alarm operational: XYes ❑ No f. High water alarm count: (PL(ft tf U g. Pump Run Counts:33 3 C)p h. Pump Run Time: i. Float Error Counts: 'KFN/A j. Total Override Counts: TVN/A k. Effluent Filter serviced: ! ^J�Yes ❑ No I. Tank lids secured after inspection: AYes ❑ No m. Weep hole functional: Les ❑ No 9. Primary Tank: El Acceptable [: {Tnacceptable a. Sludge and scum level checkev,: 1, , Yes Li No t b. Sludge/Scum levels: 1st:_2nd: 3rd: c. Tank needs to be pumped: t31Yes ❑ No d. Water softener backwash discharging on system7'❑ Yes ❑ No e. How many people live on the system?: f. Tank lids/caps secured after inspection Yes ❑ No g. Last Date Tank pumped: � - 2(7.2-0 10. Drainfield: a. Type of Drainfield (circle one): Bed Deep Trench b. Design Effective depth: inchesffeet c. Checked Liquid Levels in Drainfield: KYeS ❑ No MT#1 Liquid Level: Inches MT#2 Liquid Level:_ Inches MT#3 Liquid Level: Inches MT#4 Liquid Level: Inches d. Is there any surfacing effluent?: ❑ Yes No 17933 Old Glenn Highway "Chugiak, AK 99567 office/fax: (907) 688-9433 Email: ARMServicesAKCoutlook.com (PAGE 2 of 3) ARM Septic Services, LLC 11. Is the remote monitoring system fynctioning? (if no, describe in comments) Yes L1 No ,. / a. Type of Monitoring system: w. tj b. Phone line working? ❑ Yes ❑ No N /A 12. Does this system receive an advisory notice/warning? (if so, describe in comments) i -Yes ❑ No 13. Is the system in satisfactory condition/pass inspection? (if no, describe in comments) D Yes 1 }`No Other Comments: ` U M cc L%4L-S t cl� Q1r�o �ro \,j v Service Provider: , M 60 vC/ � I) A n�.o• ' 21- 7z 1 I X11 17933 Old Glenn Highway `Chugiak, AK 99567 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com (PAGE 3 of 3) 1P Invoice Date 11/17/2022 Invoice # 2022-161 Bill To Colleen Coadic 1797 West River Dr. Eagle River, AK 99577 JR's Septic Pumping and Excavation PO Box 773415 Eagle River, AK 99577-3415 Project Leak Repair Terms Net 30 Thank you for your business. Phone # 9076946454 E-mail jrsseptic@gmail.com Web Site www.jrspumping.com Total Balance Due Payments/Credits Cash, Check, and Credit Card are all accepted payment methods. DescriptionQuantity Rate Amount Equipment/crew to repair frost jacked foundation cleanout, first compartment cleanout, and leaking manhole riser. Expected 4-10 hours, only actual time will be invoiced. 7.5 hours actual. 7.5 250.00 1,875.00 3 bags of Bentanite/hole seal. 1 rubber coupling.1 170.00 170.00 $2,045.00 $2,045.00 $0.00 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this .2 jq*k- Day of 2082, by and between herein the "OWNER," and the Municipality of Anchorage, herein the "MUNI IPA TY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as —O-U-cc located at (legal description) 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) )noo Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page I of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. _)50 Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. ,jurisdiction: ('liaice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: r (signature) Date: a d- Za (print name) STATE OF ALASKA TFURD JUDICIAL DISTRICT The foregoi 20ff , by _ ss. ad before me this �� day of � C Zon C FOR ALASKA My Com xpires: Ou )D 2 MUNICIPALITY: • L0IIISE "''�. ��15 SOF . ` sAkr ,40411 (signature) Date: (print name) Title: (rev. 05/18/2018) Page 3 of 3 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this `��i Day of of 20 by and between 'A u .� � herein the "OWNER," and the Municipality of Anchorage; herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description) ' k- 2. 2. Maintenance. Repairs and Alterations. (Owner is required to read, understand and initial each section) _ Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page I of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. bL Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. _22 Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. 244 Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severahiiity. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By. (signature) (print name) STATE OF ALASKA THIRD JUDICIAL DISTRICT The foregoing i 201 . by MUNICIPALITY• was Date: ) ss. r�- before me this e;� day of IC FOR ALAS expires: _(signature) Date: (print name) Title: (rev. 05/18/2018) Page 3 of 3 Permit Number: OSP101108 Tax Code Number: 07802117000 Work Type: WellSeptic Permit Effective Dates: July 14, 2010 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial to July 14, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: SOUTHFORK NORTH Site LegalAddress: SOUTHFORK NORTH TR D G:1059 Owner/Address: THOMSON JOHN E 11404 JESSIE MAE CIR EAGLE RIVER AK 995770000 Site Mailing Address: Lot Size in Sq Ft: 165611 Total Bedrooms: 7 ¥( This permit is fOr the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERHIT APPLICATION FOR A SINGLE FAHILY DWELLING O~P !O)lO ~ Parce~ ~.~. 07'~' O'Z-.I'~ 7 Property owner(s) C/O JOHN THOMSON Day phone 240-2020 Mailing address 1 1404 JESSIE MAE CIRCLE, EAGLE RIVER, AK Site address Zip Code 99577 Legal description (Sub'd, Block& Lot) SOUTHFORK NORTH SUBDIVISION; TRACT D Legal description (Township, Section & Range) LotSize ]~11 Sq. Ft. N/A Number of Bedrooms THIS APPLICATION IS FOR ( ~]all that apply): Absorption Field [] Septic Tank [] Holding Tank [--1 Privy Private Well ~] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [--] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees:5 .'~O Date of Payment: '"7] ~J ~0 Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS June 30, 2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Well and Septic System for Southfork North Subdivision; Tract D To whom it may concern: The proposed 7 bedroom house is to be served by a private well and septic system. Due to the presence of impermeable soil, shallow groundwater and the large number of bedrooms for the proposed house, we are proposing that a Quanics Aerocell system be utilized for this property. We are proposing that a new 2500 gallon S.T.E.P. tank with Quanics pump/controls, a Quanics 1050 Aerocell unit, and a 5-wide trench type drainfield. Three test holes were excavated on the property. The drainfield will be designed around the 30 foot radius of Test Hole #3. The proposed well location is shown on the attached site plan and design drawing. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: South Fork River runs along the east property line and there is an intermittent stream along the north property line. The proposed septic system will be installed 100 feet from all surface waters. 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the drainfield is a 15-20 percent slope running approximately southwest to northeast. In short there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any ~uestions, please contact us at 337-6179. Thank you for your assistance. Je~:A ~ P.E., M.S. Presi~n! ' NOTE: Attached is a site plan drawing, a design drawing, two detail drawings, and three soil logs, which are all part of the design package for this septic system. (Contact G. E.G. Ltd for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com N',/ SOUTHFORK NORTH S/D' ~APPROXMATE LOCATON /./'~.,~,.../I / I ~"~ LOT 5. BLOCK 5. ' I OF INTERMITTENT STRE. Ak~'rJ_~"r ! / ! \. X ,..-. ? , ~, ! ' , -~~;;' I / / ,2! i,ou,,~o,~.o,,,~., ~., -~ ~ , 'xN 'xX'x./..- --...~~~/ i / ~ / / ',3 ~ 55 '-... I -.~, . !$ i hA "-J .oco.c~..w~ ~/ i IX "-.] ~., H~F OFLOT i/ ~ ~~ I ''' ~/ ~ ~ ', ', ,'= ,oo' JOHN THOMSON I 240-2020 I 1 OF 4 t~ ~ ~ ~;;~ .. SIT EP~N FOR PROPOSED WELL AND SEPTIC SYSTEM 6/30/2010 (Rev. 01/05) CULVERT AND INTERMITTENT STREAM~/ PROPOSED PROPOSED (SEE PAGE 4 OF 4) GEG. Ltd. HAS A 7 PAGE LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION. THE ENGINEER. WELL DRILLER. CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. NOTE: 1. PER THE OWNER. THE HOUSE HAS GARAGE DOOR ON EACH SIDE OF HOUSE. TANK CAN BE PUMPED THROUGH GARAGE. 2. THE DRIVEWAY SLOPE SHALL BE INSTALLED ACCORDING TO MOA REQUIREMENTS. \ / ALTERNATE PROPOSED JANDY vALvE PROPOSED 7 BEDROOM HOUSE SCALE: ~" = 40' FOUNDATION CLEANOUT~ 'PROPOSED 2500 GALLON S.T.E.P. TANK WITH QUANICS PUMP & CONTROLS (SEE PAGE 5 OF 4) INSULATE FEED AND RECIRCULATION LINES WITH 4" BY 4 FEET WIDE (CENTERED OVER PIPES) INSULATION 1050 QUANICS AEROCELL UNIT (SEE PAGE 5 OF 4) NUMBER OF BEDROOMS: 7 GALLONS PER DAY (GPD): 1050 PERCOLATION RATE/S: 24- MIN./INCH ALLOWABLE APPLICATION RATE: 4-.0 MINIMUM DRAINFIELD SO.FT.: 262.5 DRAINFIELD DESIGN: MAXIMUM DEPTH: 1.5 FEET (REMOVE ALL ORGANICS) WIDTH: 5 FEET LENGTH: 60 FEET M.O.A. APPROVED SAND FILTER: 5.5+ FEET EFFECTIVE: 0.5 FEET ACTUAL SQ.FT.: 500 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENEi~L CONTRACTORS E. 'RJDOR ROAD. SUITE 101 · ANCH01~N~E. ~K 99507 ' PHONE C907).~57-5179 * FAX (907)538-3246 · ~BSITE: m.gome~aen~ineedng.com PREPARED FOR: I PHONE NUMBER: I PAGE NUMBER: JOHN THOMSON I 240-2020 LEGAL DESCRIPTION: SOUTHFORK NORTH SUBDIVISION; TRACT D TYPE OF WORK: DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM (Rev. Ol/O~) 20F4 IDRAWN BY: DATEJ:. L. M. 6/~0/2010 /--4" CLEANOUT FROM AEROCELL UNITS - ~ ~/~] 5 FEE' WIDE I ~--4" MONIUTORING TUBE 4" CL,~NOUT'-/ ,. ' CO FEET LONG DESIGN CRITERIA: NUMBER OF BEDROOMS: 7 ~LONS PER DAY (GPD): 1050 PERCO~TION ~TE/S: 24 MIN./INCH ALLOW~LE APPLI~TION ~TE: 4.0 MINIMUM D~NFIELD SQ.~.: 262.5 DRAINFIELD DESIGN: M~IMUM DEPTH: 1.5 FE~ '~' '~l ~ FI~ G~E (REMOVE ALL ORGANICS) / WIDTH: 5 FEET / LENGTH: 60 FE~ / M.O.A. APPRO~D ~D FILTER: 5.5+ FEET FILTER F~RIC~ ~ EFFECTIVE: 0.5 FEET ~ . . . / ,ACTU~ SO.F~.: aO0 ~ ~ ~ REQUIRED TO BE TOPSOILED ~ ~ ~ ~ AND HYDROSEEDED. __ ORIGINAL G~DE ~ ~ ~ ~' ~ ~ 3 . ' ,,<~ '",'~'t'~ '~' ,~,, ',)'M ~:";',t ; ,,~? ~ ',"~ ~' ~,~"" ' ~'' ~~""~"'":" 6 FEET TO IMPI~RM~LE SOILS ~ FEET WIDE ... .....~ ~ CONSULTAN~ & GENE~L CONT~CTORS ~ ~ } ............ JOHN THOMSON I 240-2020 I or ~ ~IF'.:~ I~,n _." ..~ SOUTHFORK NORTH SUBDIVISION; TRACT O J.L.M. ~:Y~"'gl~.fiR.'"~/ DETAIL DRAWING OF PROPOSED DRAINFIELD 6/50/2010 (l~v. 01/05) ¥/)_ .,~ l~e/Frey ~. bar .... · c ~ ."~{2 ...' GARNESS ENGINEERING GROUP, Ltd. ..... '.. 7. y~l ~-~-~ CONSULTANTS & GENERAL CONTRACTORS = 3701 E. TUDOR ROAD. SUITE 101 * ANCHORAGe. AK. 99507 * PHONE: (907)337-6179 * FAX: (907)338-3246 * WEBSITE: ~,ne,~engineering.¢om ISOIL LOG - PERCOLATION TESTI LEGAL DESCRIPTION: SOUTHFORK NORTH SUBDIVISION; TRACT D, PERFORMED FOR: ED WOLLERT DATE: 1 ORGANICS TEST HOLE //1I SOIL CLASSIFICATIONS /ML GW POCKETS OF CL GP GC SW CL MIXED SP w/ GM/SM/ML (IMPERMEABLE) SM SC 1 0RG ML CL OL NH CH OH DEPTH TO GROUNDWATER DATE DRY 1 O/1/01 3.5' 10/9/01 SEE ATTACHED SITE PLAN DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 10/9/01 1 3:17 - 7- - 2 3:47 30 7" O" 3 3:47 _ 7- _ 4 4:17 30 7" O" 5 4:17 _ 7" _ 6 4:47 30 7" O" PERCOLATION RATE 120+ (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. A FOUR HOUR PRESOAK WAS PERFORHED: · YES SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: COMMENTS: SITE UNSUITABLE FOR AN ON-SITE SEPTIC SYSTEM. [] NO CALEB GALL PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS ~ERiFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: GARNESS ENGINEERING GROUP, Ltd. ~ ~ ONSU'T,',nTS & ~E.£",',' CO.T.~ ='rO~S ~ ~ ,o~~.,,,...~.~,~.~. I II I ~'/ I v,,) JSOIL LOG - PERCOLATION TESTI ~~"l .... : .... ORGANICS ~~ ITEST HOLE //2 CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROAD, SUITE 101 · ANCHORAGE, AK. 99507 · PHONE: (907)337-6179 · FAX: (907)3~-3246 · WEBSITE: LEGAL DESCRIPTION: PERFORMED FOR: GM/SM/ME w/ POCKETS OF ML GM/SM/ME w/ POCKETS OF CL (WET) CL MIXED w/ SOME GM/SM/ME IMPERMEABLE SOILS LOGGED BY: SOIL CLASSIFICATIONS GW GP GH GC SW __ SP SH SC ORG ML CL OL MH CH OH DEPTH TO GROUNDWATER DATE DRY 10/1/01 3.5' lO/9/Ol 3.0' 5/30/06 SEE ATTACHED SITE PLAN DATE READING CLOCK NET TildE WATER LEVEL NET DROP TildE (ldlNUTES) READING (INCHES) 10/9/01 1 3:18 - 6- - 2 3:28 10 O" 6" 3 3:28 - 6" _ 4 3:38 10 O" 6" 5 3:38 _ 6" - 6 3:48 10 1/4" 5 3/4" 7 3:48 - 6- - 8 3:58 10 1/2" 5 1/2" 9 3:58 - 6,, _ 10 4:08 10 1/2" 5 1/2" 11 4:08 _ 6" - 12 4:18 10 1/2" 5 1/2" PERCOLATION RATE 1.8 (HIN./INCH) PERC. HOLE DIA. 6 TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. A FOUR HOUR PRESOAK WAS PERFORHED: .YES [~JNO dODY MAUS PERCOLATION TEST PERFORHED BY: CALEB GALL (INCHES) COldldENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS/P~RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: '"7/Z,/I~ ~:: ~ :~:~ ::: ~ ~ CONSULTA.~ & GENERAL CONTRACTORS ~,o, ~. ~ ~. ~.,~ ,o,. ~c<~. ~. ,,~,. ~,: (~,)~,-,,~. ~: (~,)~-~,,~ · ~,~: ,~.,,-~.~ ~ ...... :"~ ' T~ '"~ ........... - ...... ' ' (feet) ORGANICS DEPTH ~ TEST HOLE ~3~  SOIL C~SSIFICATIONS GM/SM/ML ~ OW ~ ORG w/ POCKET ~ GP ~ HL OF CL '~ GH~ CL GC OL . < SW NH ,,.-.,.,,~SP CH ~x~D ~ s~ o~ S E E ATTACH E D CL w/ SOME~ISC ~/s./.. SITE PLAN (IMPERM~BLE) DEPTH TO DATE GROUNDWATER = DRY 10/1/01 ~.o' ~o/~/o~ 7.0' ~/~o/o~ ~o 7.~' ~/2~/~o 11 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) R~ADING (INCHES) 12 10/9/01 1 3:16 - - - 2 5:46 30 4 3/4" 1 1/4" ~ 3 5 3:46 - - - 4 4:16 30 4 3/4" 1 1/4" 14 5 4:16 _ - - 6 4:36 30 4 3/4" 1 1/4" 15 16 17 PERCOLATION RATE 24 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN B~TWEEN 2.0 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORNED: ~ YES ~ NO SOILS LOGGED BY: dODY MAUS PERCOLATION TEST PERFORHED BY: CALEB GALL COHHENTS: PERFORMED BY GEG, Ltd. I, dEFFREY A. GARNESS, CERTI~ THAT THIS WA~ P~RFORMED IN ACCORDANCE WITH ALL STATE AND MUNIGIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER DRY 10/1/01 6.0' lO/9/Ol 7.0' 5/30/06 7.5' 6/22/10 DATE: IDRAWN BY: 6/30/2010 I J.L.M. LEGAL DESCRIPTION: SOUTHFORK NORTH SUBDIVISION; TRACT D TYPE OF WORK: PROFILE OF QUANClS AEROCELL SYSTEM -r~:~ o~ PREPARED FOR: JOHN THOMSON PHONE NUMBER: 240-2020 Oz ~> ZO LOT 1BLOCK 6LOT 2BLOCK 6LOT 4APLAT #2019-107LOT 5PLAT #86-205LOT 3BLOCK 5S27° 30 ' 30"E 463 .82N61° 04' 47"E 405.09N14° 45' 12"E 150.00N19° 18 ' 03"W 275.91N23° 03' 53"E 197.14N6 2 ° 0 6 ' 5 4 " W 1 0 5 . 4 8 N00° 06' 45"W 131.80S89° 58' 22"E 149.00S15° 00' 30"E 16.12L=155.95R=714.82℄ WEST R IVER DR IVE 30.0' 30.0'EDGE OF PAVEMENTTEEEWSSSSSSSC25' CREEK MAINT. ESMT.65' UNDISTURBED CREEK ESMT.100' SEPTIC SETBACK20' DRAINAGE ESMT.10' T&E ESMT .20' DRAINAGE ESMT.GRAVEL DRIVEWAYGRAVEL DRIVEWAY100' WELL RADIUS87.3 91.8164.848.328.316.4 1 8 . 1 15.4 15.410.713.810.7Tract DSouthfork North Subdivision165,611 Sq. Ft. +/-1797 West River Drive3 Story Wood Frame HouseWith Attached 2 Car GarageG E GRAVEL STAIRSPREPARED BY:FRONTIER SURVEYS, LLC650 W. 58th AVE. SUITE E, ANCHORAGE, AK 99518907-460-1686DRAWN BY: CHECKED BY: DATE: SCALE:DRAWING ID: SHEET 1 of 11.Excepting for gross negligence, the liability for this survey shall notexceed the cost of preparing this survey. Dimensions to property linesare plus/minus 0.1ft.2.This document is created by Frontier Surveys for the purpose of anas-built survey for Morgan Michelsohn, only.3.This document is based on Plat No. 88-12, Anchorage RecordingDistrict.General Notes DisclaimerLegend1. This survey complies with the ASPLS Mortgage Location Standards. The survey represents visibleimprovements and conditions at the time of the survey. This document does not constitute a boundarysurvey and is subject to any inaccuracies that a subsequent boundary survey may reveal. It is theresponsibility of the Owner to determine the existence of any easements, covenants, or restrictionwhich do no appear on the record plat. Under no circumstances should this document be used forconstruction or for establishing a boundary or fence line.PS1" = 50ft10/13/202222-549KCScale 1" = 50'AN AS-BUILT SURVEY OFTRACT DSOUTHFORK NORTH SUBDIVISION1797 WEST RIVER DRIVECONTAINING: 165,611 Sq. Ft. +/- (RECORD)RECORD PLAT: 88-12Gas Meter Electric Meter/Outside Power DeckSepticSeptic Tank M.H.EElec. PedestalWater WellTel. PedestalGESTWPierre M. StragierNo. L.S. - 981210/13/2022REGISTEREDPROFESSIONALL A N D S U RVEYOR SC