HomeMy WebLinkAboutDALZELL-SCHNEITER BLK 1 LT 1hal II- chneite Block I Lot I 01§-2 1 -10 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231286 PID Number: 015-291-10 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New N Upgrade Name BARB JACOBS ABSORPTION FIELD Site Address 0 Deep Trench 0 Wide Trench ❑ Bed ❑ Mound 10215 SCHNEITER DRIVE *ANCHOABedrooms ❑ Other Phone Number ofSoil Rating Total depth from original grade 907-830-4111 5*85 GPD/BED GPD/SF *S Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot *4 Ft. 4 DALZELL-SCHNEITER; BLOCK 1, LOT 1 Ft. Fill added above original grade Gravel length Township Range Section UNK Ft. 12 Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 4 Ft. Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line *440 Ft2 1 - Ft. Well 100'+ ** — — 25'+ TANK A Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water 100'+ 100'+ - _ GREER TANK 1500 Gal. Material Number of compartments Lot Line 5'+ 100'+ - - NA PLASTIC 2 Foundation 19+ 100'+ - _ LIFT STATION Manufacturer Capacity Remarks PER CONTRACTOR, EXISTING TANK WAS DECOMMISSIONED PER UPC Gal. *PER 1981 INSPECTION REPORT IN MOA RECORDS Alarm location Electrical installed by **SEE ATTACHED RECORD DRAWING PIPE MATERIAL House to tank EXISTI(\ Tank to D3034 Installer drainfield A+ HOME SERVICES Drainfield D3034 CO/MTD3034 Inspector GEG AND M.O.A. BENCH MARK (Assumed elevation) 1 qOAO ft Inspection 19i 11/1/2023 - Location and descri tion n� dates: tea p l" ^' 7' ' 3fd - 4th _ BOTTOM OF VERTICAL TRI AT�9( C NER OF HOUSE ON -SITE WATER AND WASTEWATER SECTION APPROVAL ngineer's Stamp Conditional Approval: of `%' 70 .:.... D � ..... ............. , J A. Q rness.� V, Septic System � P •. � y _ � Q 9. CE-795 p Approved v Date / 2 U Z �p�f� Qe Note: this approval does not include well permit requirements. G 'Prof essiolld\ �p� o, Date #AECC884 (Rev 05/02/18) PERMIT NUMBER: RECORD DRAWING PARCEL NUMBER: OSP231286 015-291-10 OTE: PIPE LOCATIONS•ARE SHOWN PER GEG SHOTS TAKEN WITH LEICA DISTO S910 LASER DISTANCE METER. SWING -TIES TO HOUSE CORNERS WERE GEN RATED IN AUTOTD. "I w U I I w ' ( Z y U�n/� \ I � VJ Q J W b 0 MILROB AVENUE EXISTING 5 BEDROOM HOUSE a DURING THE TANK INSTALL THE CONTRACTOR HAD REMOVED ABOUT 12 FEET OF THE NORTHERN PORTION OF THE DRAINFIELD. BASED UPON THIS FACT A CHANGE ORDER WAS ISSUED TO REBUILD THE DAMAGED PORTION OF THE FIELD. GEG WAS PRESENT TO INSPECT BOTTOM OF TRENCH AND TOP OF PIPE ON THE DRAINFIELD REPAIR. THE DRAINFIELD WAS REBUILT PER THE APPROVED CHANGEORDER IN MOA RECORDS. DALZELL-SCHNEITER; BLOCK 1, LOT 2 S�DBLt&2 / T I EBUILT PORTION OF DRAINFIELD /PER CONVERSATIONS WITH CONTRACTOR, THE DRAINFIELD ARC'S AND IS NOT A STRAIGHT LINE. / DRAINFIELD MAY BE OUTSIDE OF 100' WELL RADIUS. PER INSPECTION REPORT IN MOA RECORDS; THE / DRAINFIELD IS 1001+ FROM THE WELL ENGINEERING - SALES - CONSULTING GROUP, 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507' PHONE (907) 337-6179 • FAX (907) 336-3246 • WEBSITE, w gamenengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: BARB JACOBS 907-830-4111 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: DALZELL-SCHNEITER; BLOCK 1, LOT 1 D.J.G. TYPE OF WORK: DATE: SEPTIC TANK RECORD DRAWING 11/10/2023 N SCALE: IiiiaMMiiiiiiia 1"=40' PERMIT NUMBER RECORD DRAWING TOP OF TANK AT INTLET = INVERT OF BUNG AT INLET = 94.44 ELEVATIONS WERE DETERMINED FROM THE EXISTING PIPE ELEVATION. BOTTOM OF INVERT ON EXISTING DISTRIBUTION LINE WAS 93.82 TOP OF MH = 99.18 MH1 FINAL GRADE = 99.02-99.11 ST2 NEW 1500 GALLON GREER TANK 4-FEET FINAL GRADE = 99.20 FILTER FABRIC PARCEL ID NUMBER: 015-291-10 TOP OF TANK AT OUTLET = 95.04 OF PIPE = 93.82 BOTTOM OF TRENCH = 89.82 SALES E,K99N��E(GS ROAD,SUITE101 'ANCHORAGE, 07E77)3ci7F 7Igameqqer1 -FAX PREPARED FOR NUMBER: PAGE NUMBER:w_ RICHARD MAUER 907-830-4111 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: DALZELL-SCHNEITER; BLOCK 1, LOT 1 D.J.G. TYPE OF WORK: DATE: ♦ SEPTIC TANK PROFILE 11/13/2023 INVERT OF BUNG AT OUTLET = 94.14 .,aaaaarr r r � ....................... M `.y.� ..... ..................... 0 ♦♦ : Jeffrey . Garness .c4.4i AT AV LICE N E#414% ESa� ��•• #AECC884 J 7876 MILROB AVENUE co CY) z - N89051'05"E 150.00 /,T t-, 71 30 LOT I Storage 400 c1r) W Cl? 0) OH 11 'o -9.0 ci > to deck 12.0 deck - Co N N -7.0 fi 3 Story Manhole --o dp LO 70. Frame House ci lL L0 W LO well CM4 26.0 2.2 Chimney OH to Lot 2 W z 80 0 I 1.7 GH 0C) 3: C) C) Z Asphalt z U) 0 Septic vent (typ) SCALE: 1"= 50' — — — — — — — — — — — — — — — — — — — 25'Drainage & Utility Easement 30 50'Temphora Turnaround to be vacated Sc ne7 when er Dr. is dedicated & extended N89054'39"E 170.00 REVISED 11-10-23Addedn ole RECERTIFIED 11-09-23 eATE AS -BUILT NO CORNERS TIHI I Unsubdivided I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following OF Aft, described property: LOT 1, BLOCK 1, AW AW 49th DALZELL -SCHNEITER SUBDIVISION Anchorage Recording Precinct, Alaska, and that the errimprovements situated thereon are within the property lines 00 and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying i iz . adjacent thereto encroach on the premises in question and zabeth L Walatka .0 that there are no roadways, transmission lines or other AW visible easements on said property except as indicated 80M LS - , g- AW hereon. N�Ww O Dated at Anchorage, Alaska EASEMENTS OF RECORD, OTHER THANo SSIONP&- X),� this 3rd _day of AUGUST , 2023. THOSE SHOWN ON THE RECORDED FB 23-2, pg 30 % NNI I? FRED WALATKA & ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON FB 23-2, pg 30 1 r/—G/—()Z-3BE 907-248-1666 Engineers and Surveyors UNLESS OTHERWISE NOTED. FB 81-2, pg 43 This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright taw. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this producL W "ARNESS ENGINEERING GROUP, Ltd ff AeroCell ENGINEERING SA1�ES CONSULTING , .. ,. �,..., November 29, 2023 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Dalzell-Schneiter; Block 1, Lot 1 - Drainfield to Well Waiver To whom it may concern: The subject lot is served by a private well and septic system. A new cleanout and monitoring tube was installed in 2023 on the north side of the drainfield (see attached record drawing). Per the location of the new cleanout and the existing sump, it appears that the existing drainfield may encroach on the well. Based upon this possibility, we are requesting a variance from drainfield to well down to 98 feet. Justifications for granting this waiver is as follows: • The encroachment has existed for the life of the system (installed in 1978). • Water samples were pulled in 8/10/2023 and the nitrates were 5.65 mg/L • Per the MOA nitrate mapping, the nitrates are only moderately elevated for the area (east lot is 5.25 mg/L and southern lot is 6.0 mg/L) • The old steel septic tank was replaced with a new plastic septic tank. The old tank was located inside the 100' well radius. • The drainfield may be outside of the 100' well radius. Per the contractor who installed the tank, the drainfield "curved" away from the radius. • Per the inspection report in MOA records, the drainfield is 100'+ from the well. If you have any questions, please contact us at 337-6179. Thank you for your assistance. #r�Gc.ut34 t►/2gf 23 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Website: www.garnessengineering.com Municipality of Anchorage P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services. Division On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV231058 PI D#: 015-291-10 Permit#: OSP231286 Legal Description: DALZELL-SCHNEITER BLK 1 LT 1 Engineer: Jeff Garness, PE Your request for a waiver of the required 100' horizontal separation from the existing septic field to well has been approved. The approved separation distance is 98' from well to the septic field. This waiver approval applies to the existing absorption field and new septic tank only. Any future upgrade to the on -site wastewater disposal system will require all separation distances be met or another approval from this department ❑The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: iL 2 3 Approved by: Name of Reviewer .................................................................. a M M M a M ...... 1 **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231286 Work Type: SepticTank Initial Tax Code Number: 01529110000 Site Legal Address: DALZELL-SCHNEITER BLK 1 LT 1 G:2537 Site Mailing Address: 10215 SCHNEITER DR, Anchorage Owner: MAUER RICHARD D & Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: fADisposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date p�cnt i i-- % Q �+ Del) artnient Lot Size in Sq Ft: Total Bedrooms: 9/14/2023 9/13/2024 47418 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 1 t / Z / 20 -L- -3 Received By: t S J �, 'Tv l., E- G Issued By: Date: Date: 9 il /y zeL 5 MUMUPALrry OF ANCHORAGE Development Services Department ` P p Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel 1. D. 015-291-10 Property owner(s) BARB JACOBS Day phone 907-830-4111 Mailing address 10215 SCHNEITER DRIVE *ANCHORAGE, AK Site address 10215 SCHNEITER DRIVE *ANCHORAGE, AK Legal description (Sub'd., Block & Lot) DELZELL-SCHNEITER; BLOCK 1, LOT 1 Legal description (Township, Range & Section) N/A Lot Size Sq. Ft. Number of Bedrooms 4(5-BEDSEPTIC) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial 0 Single Family (SF) x❑ Septic Tank El Upgrade El(w/wo AD U) Holding Tank E]Renewal ❑ Duplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Z 2 Waiver Fees: Date of Payment: 12 S?�-, 2 Date of Payment: Receipt Number: (n Receipt Number: Permit No. C95 P L 3 1 Z R (,-) Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc ^� GARNESS ENGINEERING GROUP, Ltd. A3oCefl ENGINEERING<SALES-CONSULTING October 30'h, 2023 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic Tank Upgrade for Dalzell-Schneiter; Block 1, Lot 1 To whom it may concern: During the installation of the tank, the contractor A+ Home Services inadvertently excavated (removed) approximately 10-15 feet of the drainfield (at the north end). Per email correspondence with the MOA, the onsite department will allow A+ Home Services to reinstall the excavated portion of the drainfield as it was designed/installed in 1981, after a permit is issued. Below is a list of information regarding the proposed repair: • An adequacy test was performed in the south sump on 8/10/2023. The drainfield passed an adequacy test. • The drainfield has existed for approximately 42 years (installed in 1981). • The drainfield was installed in 85 min/inch, visually classified as GP (per the soil log by Lars Spurkland, PE in MOA records). Under current municipal code, a drainfield with this soil classification could not be installed without a sand filter. At the time of the installation, the drainfield met municipal code requirements. • The effective depth appears to be blended with native material. It was challenging to determine what was effective depth and what was native material. • The "repaired" section of field will use native material to backfill below the effective depth. • The contractor will install MOA spec drainrock to a depth of 4' below the exposed invert. • The drainfield may be as close as 98 feet from the existing well. A waiver may be requested with the record drawing. • Water samples were pulled on 8/15/2023 and the nitrates were 5.65 mg/L GEG did not perform a perolcation test, sieve analysis or soil log. We are unaware of any increased adverse impacts this repair/installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. n �.OF A r., M.S. lrL[.... . A_Gwess �'•� CE-7953 A_ F9 F9FpPROFESS0NP� ^� k'kN-, .ate - 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 / Q/ o2,3 Phone: (907) 337-6179 * Website: www.garnessengineering.com �3 0� Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231286, Curtis Townsend, 09/14/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231286, Curtis Townsend, 09/14/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231286, Curtis Townsend, 09/14/23 I~ O MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHO'-NE MAILING ADDRESS LEGAL DESCRIPTION ] Well I Absorption Dwelling PERMIT NO. ~ ~ Man ufacturer ~ ~~~ ~ ~~ Mate No. of compartments i Liq. c~aCty in gallons Inside length Width Liquid depth Z ~ ~B ~ IF HOMEMADE: ~ ~ DISTANCE Well Dwelling PERMIT NO. ~Z T~ ~ Well/ r Foundation t Nearest lot line PERMIT NO. ~__ ~ N o. oflines~ L engthofeach.~ Total length of lines ~ Top of tile to finish grade ~ , Material beneath tile Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area m Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Cla,~,~ ~ 'z~ Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO: Building foundation Sewer line Septic ta~o Absorption area(s) OTHER PIPE MATERI&LS SOIL TEST RATING INSTALLER REMARKS APPROVED ~~ DATE LEGAL 72-013 ~8) . DEF'FIRTMENT ,_I~HEALTH AND EN',,,'IRONMENTRL ~I}TECTIOh, · .. , ' ., L-];25 '"L" STREET., FtNCHOF.:AGE., F~K. 9950± t!.....~ E L L. ~ 1'4 [:, C, ~'-4 -- :5 ~ T ~ '=; ~ .~.,..~ E PERM I T Nn ,:' =:±F~:'~.'~. ':, FtF'F'LICFINT F.:NN'~LD LOWEN 2:~.9 E. INTL FIRF'T F--:D./ LOCAT I ON M I LF:OB,."SC:HNE I TER LEGAL LOT 1 BLK 1 DALZELL,/ SCHNEITER LC,]-SI~ '~,..]L, AF.:E T'-r.'PE OF SOIL ABSORPTION '_'-',"r'STEM IS: "FRENCH MAXIMUM NUMBER OF BE[:,ROOMS = 4 SOIL RATING ,::SL.] FT,-"E:R)=: 85 THE REQUIRED SIZE OF THE SnlL RE',SNRF'T!NN S'¢STEM [:, E F' T t.-~ ==' :=:: L E I"-.I ,_-:~ T H = THE LENGTH r:, ! MENS I ON IS THE LENGTH (IN FEET.':, OF THE TRENE:H OR DRFIINFIELD. THE DEPTH OF Ft TRENCH OF.: PIT IS THE DISTRNCE E,'ETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET::,. THERE IS NO SET WIDTH FOR TRENCHES. THE GRFt'v'EL [:,EF'TH IS THE MINIMUM [:,EF'TH OF -' '- ' · .~F.H,EL BETWEEN THE NUTFALL PIPE AND 'THE BOTTOM OF THE EXCFf4ATION (IN FEET). PERMIT RPPL. ICRNT HAS THE RESF'ONSIE:ILIT¥ TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF AN'¢ WELLS ADJACENT "FO THIS F'ROPERT'?' RN[:, THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. BACKFILLING OF RN'.-r' S"r'STEM 1.41THOLIT FINAL IN"-]F'ECTI ON RNE.', APPROVAL B'T' THIS [:'EPRRTMENT WILL BE SUBJECT TO PROSECLITION. MINIMUM DISTANCE E,'E'TWEEN A t.,IELL AN[." AN'¢ ON'-SITE SEWAGE DISPOSAL Sh-'STEM IS t88 FEET FOR R PRI',,/ATE WELL OF.: ±50 TO 200 FEET FROM R PUBLIC WELL DEF'END!NG UPON THE T"r'F'E OF F'UBLIC WELL MINIMUM DISTANCE FROM A PRIVATE t.4ELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUN. IT'-? SEWER LINE IS 75 FEET. .WELL LOGS ARE REbqUIRED AND MUST BE RETURNED TO THE [:'EF'RRTMENT W ITFIIN --":0 DA"r'S OF THE WELL COMPLETION. OTHER RE6!UIREMENTS MFI"r' RPPL"r'. SPECIFICRTION'-"; AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE F'ROPER INSTALLATION. F" E E: ir.1 I 'T E ;=-:: F' ]: F-: E :5 [::, E] ,2: E I"1 E: E-- F: 2~.: :.-L _. 1 S~ ;E: :.IL I E:ERTIF'T' THAT ±: t AM FAMILIAR I.,.IITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH B'.? TFIE MUNICIPALIT'T' OF ANCHORAGE. 2: I WILL INSTRL. L THE S'¢STEM IN ACCORDANCE WITH THE CODES. ~:: I UNDERSTAND THAT THE ON-SITE SEWER S¥S'TEM MR'¢ RE6!UiRE ENLARGEMENT IF THE RESIDENCE IS REME[:,ELE[, TO INCLU[:,E MORE THAN 4 E:E[:,R]]MS. SIGNE[:, '__ ~ / ~l~d~ t RF'F'L!C:A~ RONSLD LOWEN ~ 3 . / / ....... ...... PERMIT NO. FII_I~ I CIPRLITY OF DEPARTMENT Q~ERLTH AND ENVIRONMENTAL ITECTION 825 'L~TREET~ RNCHORAGE~ 2~4-4720 WELL R~WD CIN--SITE SEWER REAP1 IT APPLICANT LOCATION LEGAL RONSLD LOWEN 219 E. f~ I LR~ B, _ CHNE I TER LOT ';1. BLK t D~LZELL/ SCHNEITER INTL. ARPT RD. LOT_.cIZE ~44-5845 48000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM_IS-: TRENCH _ _ _ MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT?BR>= 85 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEF'TH= 8 LENGTH= 4~-~-- GRI~/E£, [~EPTH= 4 THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DR~INFIELD. THE DEPTH OF 8 TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET>. THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE E~CA~RTION <IN FEET). ~REQ. L!_I_~-._E_~_ _--'~--_E_?_T_I ~D TR~K S I ZE= 1250 GRLL~D~S PERMIT ~PPLIC~NT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF 8NY IIELL~ ADJACENT TO THIS PROPERTY 8ND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. Ti-lO (: -2 ) I I'~ISF'ECT I C'I~IS t-IRE REQL~ I RED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN 8 WELL AND ~NY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR 'A PRIVATE WELL OR i50 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE O~ PUBLIC WELL. - MINIMUM DISTANCE FROM A PRIVATE WELL TO R PRIVATE ~EWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQ. UIRED AND MUST BE RETURNED TO THE DEPARTblENT WITHIN ~E1 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS ~A'¢ RPPLY. SPECIFICA~'IONS AND CONSTRUCTION DIAGRAMS 8RE AVAILABLE TO INSURE PROPER INSTALLATION. PERM I T E.~-(P I RES DECEr-"IBER I CERTIFY THAT -. ,il' I AM FAMILIAR WITH THE REQUIREMENTS FOR CN-~ITE~ " =.EI IERS ~ , "AND WELLS RS SET I '~ - 'FORTH bY THE MLNIuIPFILITY OF ANCHORAGE. 2' I WILL INSTALL THE SYSTEM IN PI..CORDRNCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. '. ........ -¢_ / ISSUED EW ~~,~ __DATE_ -- MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: LOT I I~K ! ~T~ALT_.~ LL- SLOPE SITE PLAN 6 7 ~"'~8 ~S, OPTo q-/Nc~-/E s 9 7 WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? 10 11 12 13 14 S L O P E Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE (minutes/inch) -- ~ ~ TEST RUN BETWEEN FT AND FT _ /~ PERFORMED BY: ~, CERTIFIED BY DATE: 72-008 (6/79) unicipality of Anchorage Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. BOX 196650 Anchorage, Alaska 99519-6650 343-4744 June 22, 1989 Bruce Corwin, P.E. Corwin & Associates, Inc. 1000 East Dimond Boulevard, S%ite 205 Anchorage, Alaska 99515 Subject: Waiver Request fOr Lot 1 Block 1 Dalzell-Schn~iter S/D Waiver Request ~WR890026, PID #015-291-10 Dear Mr. Corwin: Your request for waiver of the required 100 foot separation of a septic system to a private well has been approved. The approved separation distance is 88 feet.~ This waiver approval applies ~o the existing septic system' to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. Sincerely,- Daniel J. Roth Civil Engineer On-site Services DJR/ljw~6 ENVIRONMENTAL SERVICES DIVISION & associates,inc. Consulting Engineers 1000 E. Dimond Blvd. · Suite 205 · Anchorage, Alaska 99515 · (907) 522-1311 June 9, 1989 Mr. Dan Roth Municipality of Anchorage Department of Health and Human Services 825 L Street Anchorage, Alaska 99501 SUBJECT: REQUEST FOR WAIVER OF SEPTIC TANK TO WELL SEPARATION DISTANCE ON LOT 1 BLK 1 DALZET.T./SCHN~TER SUBDMSION Dear Mr. Roth: When performing a Health Authority Approval on the above referenced project, it was brought to our attention that the septic tank is only 88' from the well. The system was installed in 1981 and the as-built shows that the well to tank separation distance is 100'. However, our field measurements disagree with this. We understand that your department requires our client, Federal National Mortgage Association, to apply for a waiver. We request a waiver for well to septic tank separation distance from the required 100 feet to 88 feet. Our basis for granting the waiver is as follows: This system has been in operation since 1981, and has not caused any adverse effects to the existing well water supply. The septic tank is a steel, 1500 gallon, 2 compartment Anchorage Tank and appears to be in good condition. The natural drainage from the tank is directed away from the well. The well log for this lot indicates the static water level was measured and found to be at 35'. After reviewing the well log it is apparent that we have thirty-five feet of sand and gravel which should allow adequate filtration so that the well will not be contaminated. Static water are as follows: levels of surrounding wells were measured and Dalzell/Schnieter Subdivision Leland Stanford Subdivision: Lot 1 Blk 1 35 Lot 2 Blk 1 27 Lot 3 Blk 1 28 Lot 2 Blk 2 44 Lot 14 Blk 2 42 Lot 15 Blk 2 38 Lot 3 36 We request approval of this waiver. contact us at 522-1311. If you have any questions, Very trul~?~?s, CO~,IN & ~'S oC~ATE S, v~BRUCE J .,~ CORWIN Pre~IdeDt INC. rq m'Z rq '~50,00----- 202.00 ! '- N 0c05'22'W m.-I~ ~,-_> o mm? /'f- ...... ~97.00 .... , .............. 213.8 7 ..... '- - 0°08,55" W - -'~ _279.73_~__._~/ .... Dr. ~: 101.59 >C' 1114 m--t /? / --4-- I m --I mp rtl z -4 NS~ 223; L .o~ g ~ . ogg / / ' ~ i' ,lO' UTILITY EASEMENT-._ ~ '~'~ '~30001300~j~[~' lO' UTILITY EAS E~ A-: .:-::::::-:~.~ 7-~-::-~:~ >~ ~.~.m~, .~/.~--. - ~. :'.' ~-~ ..... ~.,: ~ ~lO. OO ~ ~ BIRCH 679 C/,%/.S' &/£.¢£)/'//~-' '--~-) 989.56 proc. S0°08'55" E 1319.41 roes. " pp./ I AS-BU[LT NO CORNERS SET THIS DATE ~SEMENTS OF RECORD. OTHER THAN THOSE SHOWN ON THE RECORDED P~T ARE NOT SHOWN HEREON. I hereby certkfy that I have performed a Mo~r?gee's in- sp~ection of the following described property: ~" Anchorage Recording Precinct, Alaska, and that the improve- ments situated thereon are within the property lines and do not over]ap or encroach on the property lying adjacent there- to, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon· Dated at Anchorage, Alaska this ' -- _day of. ~': !'':' --- 19.._'_ -'- FRED WALAT},Za. & ASSt)CIATES Engineers and Surveyors ,,E~iViR, OiqMENTAL SERVICES DIVISION n JUN 1 q 1989 RECEIVED ~ ,4/ ~5/ oS&~ I~ ,/(''''- ~ ~ ~.z ~ it. · ~ ~ - ~ · i>,,:`~::.:.:?:::z::.:::~::,'::~::::::~ I , ~ ' ~ ~_ .,,,,, .~ ~ Implements ~t~u~$ed lher~n ore w~lhLn the LEGEND Jm~ovemen~ ~ pmpe~y lylno ~d]ooent ~ereto enc~oh ~ the pteml~ In ~e~lon ~nd tb~l ~ m~ent recovered there ~e no ro~ tr~n~ission lin~ ~ other Indloolnd hereon. AS-BUlL T moo ~. o~o~o e~vo. 8UIT8 205 LOT/ ~Loc~ / ANCHORAge, ALASKA ~ ~ ~ ~ - ~~1 T~ ~U~ (9 0 7) 522 - 1311 —— MILROB AVENUE co N89051'05"E 150.00 30 LOT 1 to Storage W 1,1.0 c 69.0 LO deck 12.0 deck CO ` Septic vant(typ) FY N TO + ° 70 3 Story .0 Frame o1b House 2 � v W (t— h Lo to well ci N 28.0 2.2 Chimney OH Zp 7oH S C) O Z Asphalt I I e 1 1 I 1 — ------------------- r 25' Drainage & Utility Easement 50' Temporaryry Turnaround to be vacated 30 when Schneiter Dr. is dedicated & extended N89054'39"E 170.00 Unsubdivided ASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED 11LAT ARE NOT SHOWN HEREON JNLESS OTHERWISE NOTED. ®Noy %, 1 of , �s AW 10 49th 00 00 / ; :� Elizabeth L. Wolatka �� �s,� 803 - LS �.� ®�'Fd ... • Q 5 s SS10140- ZC1BE 9 C'7 Rf') N iA Lot 2 SCALE: 1"= 50' REVISED 8-24-23 (� AS -BUILT NO RS SET THIS DATE 7876 I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT 1 BLOCK 1 DALZELL-SCHNEITER SUBDIVISION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 3rd day of AUGUST , 2023. FRED WALATKA & ASSOCIATES, L.L.C. 907-248-1686 Engineers and Surveyors This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. r ~ ·,. / =- Phone P[operty Owner Buyer Phone Lending Institution Phone Realty.-Co. & Agent Address ..... Zip Code .......... ~.Single Family [] Multiple Family No. of Bedrooms. [] Other Water Supply [~lndividual ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. [] Community For wells drilled prior to that date, give well depth (attach log if available). [] Public Utility ~..¢ !~.,~ Sewer Disposal '{~lndividual Year Individual Installed: [] Public Utility When Connected to Public Utility: [] Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Tir~3e '~'" Time Date Date Date Date Inspector Inspector Inspector Inspectop'~ (~"') APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received Well to Tank Septic Tank Size 72-023 (3/82) MUNICIPALITY F ANCHORAGE Development Services Department c 4 Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I. D. 015-291-10 Legal description DALZELL-SCHNEITER BLK 1 LT 1 Site address 10215 SCHNEITER DR Anchorage AK Current property owner(s) Barbara Jacobs Expiration Date: X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: M Original Certificate Date: This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field AdvisoryNitrate Advisory x Tank Age Advisory Arsenic Advisory Other COSA Approval —June 2022 Development Services Department rr ~Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 015-291-10 Complete legal description DALZELL-SCHNEITER; BLOCK 1, LOT 1 Location (site address) 10215 SCHNEITER DRIVE ANCHORAGE, AK Current property owner(s) BARB JACOBS 2. ON -SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 907-830-4111 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: R Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel X Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Z `oO Date of Payment 1 //Z I A 3 cosA # O.i C1,2� I H 50 Waiver Fee $ Date of Payment Waiver # COSAApplication_June 2022 COSA Checklist Legal Description: DALZELL-SCHNEITER; BLOCK 1, LOT 1 Parcel ID: 015-291-10 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA Al Well log is filed with Onsite (or attached) Date drilled 6/10/1981 Total depth 52 ft Cased to LINK ft D. Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 8/10/2023 Static water level at beginning of test 30.2 ft. Comments B. TANK DATA Measured operating fluid level in septic tank NEW Date of pumping - ❑ Required maintenance completed, if AWWTS Comments: NEW SEPTIC TANK - SEE ATTACHED RECORD DRAWINGS D. ABSORPTION FIELD DATA Which system tested (date installed) 7/10/81 & 11/3/2023 ❑■ ALL standpipes present per record drawing Total measured depth from grade 9.38 ft (max) Measured depth to pipe invert from grade 5.38 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. F0 Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced N/A gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Well production at time of test 4.4+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes 0 Nc AM Coliform bacteria is Negative Nitrate 5.65 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L 0 Arsenic less than MRL (ND) Collected by GEG Date 8/10/2023 C. LIFT STATION ❑ Required maintenance Age of lift station r Lift station erial Adequacy test date 8/10/2023 Results g Pass Fluid depth prior to test 0 Water added 993 gal New fluid depth *10 in Elapsed time 25 min Final fluid depth 0 in in Absorption rate 750+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 48 in Effective depth used 0 in Effective depth remaining 48 in Comments/Deficiencies: "AT THE TIME OF THE TEST, THE BOTTOM OF THE SUMP ONLY EXTENDED 1.5 FEET BELOW THE INVERT WATER WAS NOT NOTED IN THE SUMP FOR THE FIRST 276 GALLONS. THE DRAINFIELD WAS DRY DURING MT INSTALLATION ON 11/3/23 COSA Checklist —June 2022 ii�i3/23 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' QYes if No ft Me Yes if No ft Neighboring Tank > 100' no Yes if No ft Private Sewer/Septic Line > 25' Q Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No * ft Holding Tank > 100' FE-1 Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft 0 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' E Yes if No ft Q Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' g Yes if No ft Surface Water > 100' R Yes if No ft Tank to Property Line > 5' R Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' M Yes if No ft Private Wells > 100' Fn� Yes if No ft Water Main > 10' M Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS 'SEE ATTACHED RECORD DRAWING REGARDING SEPARATION DISTANCE OF EXISTING POR ION OF DRAINFIELD TO WELL SEE ATTACHED RECORD DRAWING FOR COMMENTS OF DRAINFIELD G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Gayness Engineering Group, LTD. (GEG) Engineer's Printed Name Jeffrey A. Gayness Phone 907-337-6179 Date di I �+123 In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. COSA Checklist June 2022 O F . �U��4 �....:... ........... �... .. f ey A G ness.:... Q� r 4Q4C LICENSE�profession o #AECC884 i?irVos,q tt�a�%�-�yu Nitrate Advisory Certificate of On -Site Systems Approval # OSC231450 Subdivision: DALZELL-SCHNEITER, Block: 1, Lot: 1 A water sample revealed a nitrate concentration of 5.65 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.