Loading...
HomeMy WebLinkAboutT15N R1W SEC 5 LT 32 & LT 33 N3T1 N RIW ec. Lot & 33 N3 051-032 -42  Municipality of Anchorage Development Services Department ~x :~--::::~ Building Safety Division On-Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: OSP101155 PID Number: 051 --05--242 Name: FRANCES RUSH Wastewater System: · New [] Upgrade Address: PO BOX 670445 *CHUGIAK, AK 99567 ABSORPTION FIELD Phane: No. of Bedrooms: C/O AGENT 5 [] Deep Trench [] Shallow Trench I Bed OMound mOther LEGAL DESCRIPTION ~oi, Rating: Total Depth from original grade: 0.7 GPO/Sq. Ft. 5.89 TO TOP OF SAND rt. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Grovel depth beneath pipe: - N 1/3 OF LOT 55 - 5.32 Ft. 0.57 Ft. Fill added above original grade: Grovel length: Township: 15N Range: 1W Section: 5 SEE DWG. rt. 76 Ft., Grovel width: Number of lines: Distance between lines:I WELL: [] New [] Upgrade 15 rt. 5 5 rt. ClassificoUon (Private, A,B,D): Total Depth: Cased To: Total obsorpUon oreo: Pipe materlol: PRIVATE 121 rt. 121 ~t. 1140 so. rt. D 3054/ F-810 Driller:. Dote Drilled: Static Water Level: Installer: Dote installed: WHEATON WATER WELLS 5/7/11 15 Ft. DIRT WORKS 11/12-17/2010 Yield: Pump Set At: Coslng Height Above Ground: 4 GP~ 112 Pt. 2 .t. TAN K SEPARATION DISTANCES I Septic E] Holding [] S.T.E.P. [] Other* T~o Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: Tank Field Station Tank Sewer Lines GREER 1500 Material: Number of comportments: Well 100'+ 100'+ -- -- 25'+ STEEL 2 Surface Water 100'+ 100'+ - - - LIFT STATION Lot Line 5'+ 10'+ -- __ __ Size ~n gallons: I Manufacturer:' Curtain Drain ' NONE KNOWN . Pump~ctrlcol Inspections performed by: I ~mo~: BENCH MARK Location and Description: GARAGE FLOOR SLAB @ NE CORNER. As .... d ~'levotion: 100o00 ENGINEER'S SEAL Inspections performed by: COG, Ltd. Dates: 1st 11/12/2010 2nd 11/12/2010 ~ OF 3rd 11/17/2010 Development Services Department Approval ~' 4~ Reviewed and approved by:~ Dote: ( PERMIT NUMBER: AS BUILT DRAWING PARCELID NUMBER: OSP1 01 1 55 - 051 -03-242 DESIGN CRITERIA RESERVE SITE: \ A D B NUMBER OF BEDROOMS: 5 \ DBL1 41.36 104.17 40.39 :/ \ DBL2 43.34 102.42 41o95 GALLONS PER DAY (GPD): 750 PERCO~TION RATE/S: <1 MINUTE/INCH \ DBL3 46.19 99.07 45.40 PROPOSED APPLICATION ~TE: 4.0 %~. DBL4 47.90 97.19 47.15 MINIMUM DRAINFIELD SQ.~.: 188 ~'~. DBL5 53.34 102.75 43.90 RESERVE DRAINFIELD DESIGN: ~ - DBL6 54.71 103.21 44.47 ~ ST1 46.86 101.03 43.05 M~IMUM DEPTH: 8.0 FE~ WIDTH: 5 FE~ ST2 52.17 ~03.16 43.13 LENGTH: 40 FE~ MT1 61.16 87.62 56.98 M.O.A. APPROVED SAND FILTER: 2 FE~ C03 60.61 88.93 55.89 EFFECTIVE: 0.5 FE~ C02 62.49 90.22 55.88 ACTUAL SQ.~.: 200 ~ C01 65.26 91.09 56.98 ~ MT2 66,69 90.97 57.88 ~ ~WATERLINE W~ INSTALLED PRIOR TO MT3 132 14 18 66 150.66 ~. / DRAINFIELD. WATERLINE LOCATION WAS ' ' ~% / F~GGED BY CONTRACTOR. C06 132.07 19,96 130.51 / x, / C05 133.62 23.12 131.03 / N / , 004 134.77 27.83 151.18 ~ NEW 4 BEDROOM , MT3 HOUSE DeL C/O'S 1 ~~' ~ GARAGE/SHOP ' -- NEW WELL DBL C/O'S ~ .... ~ / ~RESERVE SITE WILL / REQUIRE ADVACED ~ ~ ~ ~ / TR~TMENT. ~ / ~ , ~ x x AREA~ ~PE OF WOrk". DATE'. AS-BUILT DRAWING 11/19/2010 ~~ PERMIT NUMBER: AS BUILT DRAWING PARCELID NUMBER: OSP101155 - 051 -0.3-242 *EXTRA COVER OVER TANK TO ACCOUNT] FOR SETFLING IN SPRING 2011. J TOP OF TANK -..--% AT INLET = 9,3.89 ~/ ~ ,, / INVERT OF BUNG j AT INLET = 93.40 *FINAL GRADE = 98.40 ? ST 1 / ST2 AT OUTLET = 93.90 NEW 1500 GALLON /-~-~ SEPTIC TANK __~ ~-INVERT OF BUNG AT OUTLET = 93.14 '-- BOTFOM OF BED ~ j~ RELATIVE ELEVATIC~ :;'SE4OTTOM OF ~ RELATIVE ELEVATION OF BoTroM OF TESHOLE =82.54 (DRY) TESHOLE =84.54 WATER @ 85.54 GARNESS ENGINEiERING GROUP, Ltd. CONSULTANTS & GENERAL CONTFLACTORS 3701 I:' 'ruDoR ROAD, SUITE 101 * ANCHORAGF. AK 99507 * PHONE (907)~37-6179 * FAX (907):t38-3246 * WEBSffE: www.gornessengineeHng.com PREPARED FOR: PHONE NUMBER: ] PAGE NUMBER: FRANCES RUSH C/O AGENT I 2 OF 3 LEGAL DESCRIPTION: ]DRAWN BY: T15N, RlW, SEC 5, N1 /3 OF LOT 33 I PNB TYPE OF WORK:IIlDATE:1 PROFILE DRAWING /19/2010 A~ Gorness: ;CE-795, Mar 29 11 02:40p Wheaton Water Wells, Inc. 907-376-2030 Ma rk B egich Mayor Developing-hr 5ervfces Department Buildin9 Safel-y bivision On-Site Water & Wastewater Program 4700 Elmor¢ Street P.O. go× 196650 Anchorage, AK 99§19-6650 ~'eJw.mu ni.orq/ons i~e (9o7) 3~3-7~o~ Pump Installation Log Well Drilling Permit Number: O~ P / ¢¢/l~.~ Date of Issue: , - Parcel Identification Number: - Legal Description Block Lot Property Owner ~qame & Address: ' ~ump[nst~llationDate: 3 - 10 - I[ ' Pump I~take Depth Below Top of Well Casing: //~ ~ feet Pump Manufacturer's Name P.mp Size ¢~ bp Pitless Adapter B.riM Dept~: /~+ feet ~itless Adapter Manufacturer's Name: ~'~ ~O~ Well Disinfected Upon Completion? ~Yes No Method of Disinfection: Comments: Mailing Address: ~ 0 ~O~ Attention: The pump installer shall provide a pump installation log to DSD within 30 days of pump installation. Mar 29 11 02:39p Wheaton Water Wells, Inc. 907-376-2030 ~/'it]~lTOl~I ~ATEg llrl~I_J,S, INC. ~5~71~1S, ~/itras~, ~ 9~S7 (907) 37~-2041 Name: Preferred Custom Homes of Alaska Address: 3220 N. Arabian Lane City: Palmer State: AK Zip Code: 99645 Well Site: T15N, R1W, S5 Lot: 33 Block: Additional: Municipality of Anchorage Permit #OSP101155 ':Well Depth: 12t ft. Below Ground: 119 ft. Above Ground: 2 ft. GalfMin: 4 Static Level: 13 ft. Uasing: Liner Pipe: Screened: Perforated: Grouted: Depth: Develop. Method: Use of Wel[: Residential Drilling Method: Rotary Fluids Used: none Pump Installed: none Other: none t21' of 6" ID Steel rlOlle none none Bentonite 20' + Air From: To: 0 1 1 30 30 36 36 64 64 117 t17 12I Formation: topsoil wet silty gravel, sand, boulders silt fine silty sand, some gravel fine silty sand, gravel silty, gravel, sand, water ~)ate Drilled: 3-7-2011 Driller: Milo Pimer ASBUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: AND NO .NCaO C.MENTS INDICATED. IT IS THE RESPONSIOILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS~ OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OF FENCE LINES, OR FOR ESTABLISHING BOUND- ARY LINES. SEWARD & ASSOCIATES LAND SURVEYING SCALE; DATE~ GRID.' FB: 694-0829 Nov. Ii, ZUlU 1U'b3AM Garness Lnaineerina Group, Ltd. No.0085 P, 1 Municipality of Anchorage ONSITE WATER & WASTEWATER PROGRAM Ctt~MNGE ORDER, CONTACT PERSON ,~ mO~ ~ Ad PHONE ~)~'~ "~ ~ '7 ~ FAX PLEASE GIVE A DESCR[PT!ON OF THE CHANGE ..~,~.~a,~.-/'.~...~.. It~i~'"/'~.C~'O . ~~ LI~' CUSTOMER -= '2*0 On-Site, Commeats I' Review Issued Time (date) APPROVED (date) HOURLY ~TE $,,1..30 TOTAL TO BE PAZD/V~~ DATE PAID . / RECEIPT ~ On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101155 Tax Code Number: 05103242000 Work Type: WellSeptic Initial Permit Effective Dates: August 19, 2010 to August 19, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T15N R1W SEC 5 Site Legal Address: T15N R1W SEC 5 LT 32 & LT 33 N3 G:1557 Owner/Address: RUSH FRANCES N PO BOX 670443 CHUGIAK AK 995670443 Site Mailing Address: 22331 DAVIDSON DR, Chugiak Lot Size in Sq Ft: 79424 Total Bedrooms: 5 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Change Order #1 revises the location of the drainfield. Received Date: Issued By: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAI"'llLY DWELLING Parcel I.D. 0~'~-- 0'L~c~- L~0~ Property owner(s) C/O BROOK STILTNER Day phone 694-4800 Mailing address 11525 OLD GLENN HIGHWAY, EAGLE RIVER, AK Site address Zip Code 99577 Legaldescription(Sub'd, Block&Lot) N 1/5 OF BLM LOT 33 ar /-~+~ Legal description (Township, Section & Range) T15N, RIW, SECTION 5 Lot Size Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR ( [~]all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd, Permit/Rush Fees: Date of Payment: Receipt Number: (~ev. ~ ~/o5) Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS October 11, 2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Revisions to Septic Permit #OSP101155 for T15N, R1W, Section 5; N 1/3 of BLM Lot 33 To whom it may concern: Per the request of the owner, we have revised the septic system design for the referenced property. An additional test hole with soils classification, groundwater monitoring and percolation test was performed. Due to the new location of the garage/shop, we have moved the proposed septic site west of the original proposed location. The drainfield will be centered around TH#3 and TH#2. We have monitored TH#3 through high groundwater season and have modified the design accordingly. We request the sewer permit be amended to include these proposed changes. I am unaware/ systems. If assistanc Pre~/'del )f any adverse impacts this installation would have on adjacent wells or septic u have any questions, please contact me at 337-6179. Thank you for your '~ P.E., M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com GARNESS ENGINEERING GROUP, Ltd. August 9, 2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Well and Septic System for T15N, RIW, Section 5; N 1/3 of BLM Lot 33 To whom it may concern: The proposed 5 bedroom house will be served by a private well and septic system. Two test holes were excavated on the property. The proposed septic system will be designed around the 30 foot radii of these test holes. We are proposing that a 1500 gallon septic tank and a bed type drainfield with 2 foot sand filter be installed. The proposed well location is shown on the attached site plan. Comments regarding the proposed design are summarized as follows: 1. SOILS: Attached is a log which shows the soil classifications, groundwater monitoring, and the percolation test results. Since the percolation rate for the test holes were found to be less than 1 minute/inch, a sand filter is required and we have used a 0.7 gallons/day/ft2 application rate for this design. 2. BED DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing, the area around the drainfield is generally flat. In short there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you any questions, please contact me at 337-6179. Thank you for your assistance. Pres ~.E., M.S. NOTE: Attached is a site plan drawing, a design drawing, two soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 10l * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com / T15N, RlW. SECTION/5, LOT 24 / / /,,' x.,q ,,,/' xj T15N, RIW, i ~ECTION .5, LOT 25 ~ PROPOSED WELL- i /~--~/.. -PROPOSED 5 BEDROOM HOUSE X ~ / ' , ~--PROPOSED SEpTIc SYSTEM / I / . // (SEE DESIGN CRITERIA) : \ / / ,/ ~~ ~ I SECTION 5 LOT 34 ~. I ) I --~' ~ 7 ~--~ I 7 I~ /~ ~,N k. ~ / ~ ~ ~ / THj3J ~ ~ LTH[1 / ~0 ~ -- -- ~ERNA~ITE] LTHt2" ~-- 1/ /~ . ~ ~SEPTIC LOT 33 Ul~O' ~ ] '~ ~;?~ H P ~ J / ..... ': ~ ~ ~ ~ LOT ~3, S 1/3 T15N, RIW, ~ T15N, RIW, ECTION S, LOT .39 ~ SECTION 5, LOT 40 GARAGE/SHOP SCALE: 1" = 100' / e ness q"~' C' '~ SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM 10/8/2010 :~~ / / \ GEG. Ltd. HAS A 7 PAGE SPECIFICATION DESIGN CRITERIA: \ LETTER THAT PERTAINS TO THIS DESIGN. NUMBER OF BEDROOMS: 5 ~ TO OBTAIN A COPY OF THE LEI-FER // CONTACT GEG. BY PROCEEDING FORWARD GALLONS PER DAY (GPD): 750 ~ WITH THIS INSTALLATION. THE ENGINEER. PERCOLATION RATE/S: <1 &: 2.5 MIN./INCH ~ WELL DRILLER, CONTRACTOR AND PROPOSED APPLICATION RATE: 0.70 % PROPERTY OWNER AGREE THAT THEY MINIMUM DRAINFIELD SQ.FT.: 1072 HAVE READ THESE SPECIFICATIONS AND DRAINFIELD DESIGN: ,/~// AGREE CONDITIoNsTO ACCEPT OUTLINED.THE TERMS AND MAXIMUM DEPTH: 8 FEET WIDTH: 15 FEET "-- LENGTH: 75 FEET M.O.A. APPROVED SAND FILTER: 2 FEET EFFECTIVE: 0.5 FEET /--INSTALL FOUNDATION CLEANOUT ACTUAL SQ.F-F.: 1125 / ',~ //~INSTALL 4" BY 4' WIDE (CENTERED _.i' x // OVER PIPE) OF RIGID INSULATION ...~/ " / / UNDER DRIVEWAY ~ PROPOSED DRAINFIELD "~ ~ ' (SEE DESIGN CRITERIA) ~ , / / ~--PROPOSED1500GALLONSEPTIC TANK / ~ ~ : 50' BLM ESMT. ~ /co: ..... , ! !~P ~O&O~SnEnC PROPOSED /~. /~ ; ~ pRnpn¢:ED t\ 5 BEDROOM / I ' AI~,'~ ~'H P H G GE/S 0 ~ __ -]- - - 7 7- .... 7- - - --~-T T .... ~ INSTALL DOUBLE CLEANOUTS -,,,/ -- PROPOSED WATER LINE J / ~ ~x. MUST BE 10'+ FROM SEWER LINE CLEANOUTJ ! ~ .-~ /~ ~ INSTALL FOUNDATION - ~ ~ ~ c~",~/~ ~x ~ NOTE: THE CONTRACTOR SHALL HAVE THE 50 ~ x. _ FOOT BLM EASEMENTS THE SOUTH LOT LINE ,,.,?/Y .~_ /'~X X ~ AND THE EAST LOT LI~IE FLAGGED BY A ' I '%Y _,.~3~'''' ~ ~ ~._CC-~T,r" REGISTERED LAND SURVEYOR PRIOR TO ANY ~/ ..¥~/~/ o ~_~-. ,~ CONSTRUCT,ON. IN/ .~ ,~ ~ ~ AREA-~ / ,~/ ~ ~ x ~:: 0 /. ' x'"':;:F :~ J GARNESS ENGINEERING GROUP, Ltd ""~[..~. '"-~ PREPARED FOR BROOK STILTNERI694-4a00 I 2 OF 2 ~"~ ~ ".~lf~A~ess.-' , ~~v,. '.II~E- 75 (Rev. 01/05) G.ARNiESS ENGIN'EER.ING~ G. ROUP, Ltd.. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROAD. SUITE 101 * ANCHORAGE, AK. 99507 * PHONE: (907)337-6179 * FAX: (907)358-32~6 * WEBSITE: gomessengineering.com ISOIL LOG - PERCOLATION TESTI LEGAL DESCRIPTION: T15N, RlW, SECTION 5, N 1/5 OF BLM LOT 55 PERFORMED FOR: BROOK STILTNER DATE: 8/2/2010 ORGANICS TEST HOLE #1 SOILS LOGGED BY: COMMENTS: GP TO SP W/ LENSES OF SP THORUGHOUT SOIL CLASSIFICATIONS GW ~ ORG GP NIL GN CL GC OL SW NIH SP CH SM OH SC DEPTH TO GROUNDWATER DATE 15' 8/2/2010 12' 8/9/2010 SEE ATTACHED SITE PLAN DATE READING CLOCK NET TIME WATER LEVEL NET DROP TINE (MINUTES) READING (INCHES) 8/3/2010 1 - _ 6- _ 2 - <4 0" 6" 5 - _ 6- _ 4 - <4 0" 6" 5 - _ 6,, _ 6 - <4 O" 6" 7 - _ 6- _ 8 - <4 O" 6" PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. A FOUR HOUR PRESOAK WAS PERFORMED: [] YES · NO JODY MAUS PERCOLATION TEST PERFORMED BY: ROB CAMPBELL PERFORMED BY GE(;, Ltd. I, JEFFREY A. (;ARNESS, CERTIFY THAT THIS WAS PI~RFO~RMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL (;UIDELINES IN EFFECT ON THIS DATE: GARNESS ENGINiEERING GROUP, Ltd. '~ CONSULTANTS & GENERAL C;~O, NTRACTORS 01 E. TUDOR ROAD. SUITE 101 ' ~NCHORA~E.~ ~ ~ SO[~ LOG - PE._RC_OLAT/ON TEST LEGAL DESCRIPTION: T15N, RlW, SECTION 5, N 1/5 OF BLM LOT ,35 PERFORMED FOR: BROOK STILTNER DATE: 8/2/2010 ORGANICS 5701 E. TUDOR ROAD, SUITE 101 ' HICHOR.'~E. N(. 99507 ' PHONE: (907)357-6179 ' FAX: (907)538-3246 · WEBSITE: go~ngineedng.com TEST HOLE #2 SOIL CLASSIFICATIONS GP TO SP W/ LENSES OF SP THORUGHOUT SOILS LOGGED BY: GW ~ ORG GP ML GM CL GC OL SW MH SP CH __ SM OH SC DEPTH TO GROUNDWATER DATE 12' 8/2/2010 12' 8/9/2010 DRY 9/29/2010 SEE ATTACHED SITE PLAN DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 8/,3/2010 1 - _ 6" _ 2 '~ <4 0" - 6" 4 - <4 0" 6" 5 - _ 6,, _ 6 - <4 0" --~6;' ' 7 - _ 6,, _ 8 - <4 0" 6" PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. A FOUR HOUR PRESOAK WAS PERFORMED: [] YES · NO JODY MAUS PERCOLATION TEST PERFORMED BY: ROB CAMPBELL COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE~FC)RMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~[J,./(c, GARNESS ENGINiEERING GROUP, Ltd. ~'=~=- CONSULTANTS & GENERAl_ SOIl-O-ii LOG - P~R~QLAT~N TEST LEGAL DESCRIPTION: T15N, RlW, SECTION S, N 1/3 OF BLM LOT PERFORMED FOR: BROOK STILTNER DATE: 8/2/2010 ORGANICS 3701 £. TUDOR ROAD. SUITE 101 ' ANCHORA~£, AK, 99507 ' PHONE: (907)337-6179 ' FAX: (DOT)3.xS-.,~I246 · WE:BSITE: 9m'ne~eng;neer;ng.com [TEST HOLE SOIL CLASSIFICATIONS SM LENSE MIXED WITH GP TO SP GP TO SP W/ LENSES OF SP THROUGHOUT GW ~ ORG GP ML GM CL GC OL SW MH SP CH __ SM OH SC DEPTH TO GROUNDWATER DATE DAMP @ 13' 9/29/2010 DRY 10/8/2010 SEE ATTACHED SITE PLAN DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (HINUTES) READING (INCHES) 10/8/2010 1 - _ 6- _ 2 - - 10 MIN. 2" 4,, - 3 -- _ _ - 6, - _ 4 - 10 MIN. 2" 4" 5 - _ 6,, _ 6 - 1--6' MIN. 2" 4" 7 - _ 6,, _ 8 - 10 MIN. 2" 4" 9 - _ 6,, _ 10 - 10 MIN. 2" 4" 11 - _ 6,, _ 12 - 10 MIN. 2" 4" PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES SOILS LOGGED BY: COMMENTS: TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. A FOUR HOUR PRESOAK WAS PERFORMED: 1YES dODY MAUS PERCOLATION TEST PERFORMED BY: E~NO JODY MAUS PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS /PEF~FORMED IN ACCORDANCE WITHALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I hereby ce~ify ~hat/~.% have .s~veyed ~he following ~_.~. ~ ~ .~ ~ ~. ~' '~ t~ ~ ~ ~ ~ ~ ~ ~ · . ,~ ~ ~ Anchorage ~,ecordin~ ~eci~ct~ ~_~l-% pqsed ~p~oyements, as planned thereo~'~ w~ be wphm }~e property.lines and will not overlap or ~oacn on ~ne proper~y ~y~a adjacent thereto, :ihat no ~provements on property lying adjacent th~eto no roadways, transmission lines or other visible ease- ~~1~'~'~ . ments on sam property except as indicated hereon. Dated at Eagle Enter, Alaska It is the responsibffi~ of ~e B~der to / field check ~st~ces to lot ~es prior day of / . to co~en~g consWacfion. ROBERT C. JOHNSON SC~E: Registered ~and S~eyor No. 880-LS 1"= ~0 Box 456, Eagle River, Alaska Phone 694-~543 CERTIFICATE FOR A Parcel I.D. 051-032-42 1. GENERAL INFORMATION Municipality of AnChorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Eknore Road P.O, Box 196650. Anchorage, AK 99519-6650 . www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEHS :APPROVAL SINGLE FAHILY DWELLING Expiration Date: ~ /7_'¢[ // ./ Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address T15N, RIW, SEC 5, N 1//3 OF LOT 33 22331 DAVIDSON DRIVE *EAGLE RIVER~ AK FRANCES RUSH Day phone C/O AGENT 22331 DAVIDSON DRIVE *CHUGIAK, AK Day phone BROOKE STILTNER W// REMAX Day phone 694-4200 16600 CENTERFIELD DRIVE *EAGLE RIVER, AK 99577 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well · Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the tr:ansfer of title (except between spOuses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. STATEMENT OF ~NSPECT~ON 8Y ENG!NEER ve.,y Lh~,L mz As certi[~d by my seal ed hereto and as of the validation date shown be/ow, I"" ...... investigation, .-ba~n...: ~: , .,.:°~Scedures~ outlined in the Ce~ificate of On-Site ~ystems ~ppmval Guidelines. ~or this application, o, s~, u~ure indicated ,ffemin. I fu~her verify that based on the for the number o~ bedrooms and type ' '~, .... ,, ~n~om~uo~ uu~i~ud ~-om.~*~ ,v~u.~u,H=.~y u, ~,,~,~o, ~= files and from my ¢-,,~,/~¢,¢~. an~ i.sp~,¢o., on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of instaflation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E, Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide an.y warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is fo.r the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right v¢,ffatsoever. DSD SIGNATURE //'" Approved for ~ bedrooms, Disapproved. Conditional approval for Attachments: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. 11105) bedrooms, with the following ,, ~,.,:_~ .. ·. .. ~'~.. ArseR,O AdvisoF] Maintenance Agreements Supplemental' Engineer's Repo~ Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: T15N, RlW, SEC 5, N 1/3 OF LOT 33 WELL DATA Well type PRIVATE *PER CONVERSATION WITH DRILLER. IfA, B, or C provide PWSID# N/A Parcel ID: 051-032-42 Date completed 3/7/11 Total depth 121 .ft. Date of test Static water level 13 Well production 4 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Arsenic: 11.6 ugJL SEPTIC/HOLDING TANK DATA Tank Type/Material Tanksize 1500 gal. Sanitary seal (Y/N) YES Cased to '12i .ft. FROM WELL LOG 3/7/11 .ft. g.p.m. Nitrate 0.1 mg./L. Date of sample: 3/18/11 SEPTIC/STEEL Number of Compartments 2 Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 24 AT INSPECTION NEW WELL J g.p.m. Collected by: GEG, Ltd. Foundation cleanout (Y/N) YES Date of pumping NEW ABSORPTION FIELD DATA Date installed 11/12-17/11 Length 76 ft. Depression over tank (Y/N) NO Pumper. I'BELOW EXISTING GRADEI Soil rating (g.p.d./ft2o~ 0.7 Width 15 ft. Total depth *5.57 ft. Date of adequacy test PUBLIC SEWER Date installed 1 1/12-17/1 1 Cleanouts (Y/N) YES High water alarm (Y/N) N/A in. Wateradded - gal. New depth - in. in. Absorption rate >= 750+ g.p.d. NONE KNOWN If yes, give date - Fluid depth in absorption field before test - in. Elapsed Time: - min. Final fluid depth - Any rejuvenation treatment (past 12 mo.) (Y/N & type) System type BED Gravel below pipe 0.57 .ft. Eft. absorption area 1140 ft2 Monitoring tube YES Depression over field ~{I' '/-~ NEW Results(Pass/Fail) PASS For 5 bedrooms D. LIFT STATION Date installed "Pump on" level at E. in. SEPARATION DISTANCES Size in gallons "Pump off', leveL~--------h~---- Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot. 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'+ 100'+ Manhole/Access (Y/_~ J High water alarm level at Meets alarm & circuit requirements? On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A N/A Manure/animal excrete storage areas 100'+ Building foundation Water main Wells on adjacent lots SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: 5'+ Property line 5'+ N/'A Water service line. 10'+ 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots. 100'+ Absorption field 5'+ Surface water. 100'+ Building foundation 10'+ Water main N/A Driveway, parking/vehicle storage .in. 10'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined thr'oughfield inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this Engineer's Printed Name Date COSA Fee $ Date of Payment Receipt Number (05--' (Rev. 11/05) JEFFREY A. GARNESS Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Community Development Department Development Services Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Arsenic Advisory Certificate of On-Site Systems Approval # OSC 111089 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Lot 32 and 33 N2 of T15N R1W Sec 5 Subdivision. This inspection revealed an arsenic concentration of 11.6 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On-Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval.