Municipality of Anchorage
Development Services Department ~'~
Building Safety Division
On-Site Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 4
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: OSP101160 PID Number: 05133307000
Name:
Dennis Anderson Wastewater System: [] New [] Upgrade
Address:
18820 Fish Hatchery Rd., Anchorage, AK 99577 ABSORPTION FIELD
Phone: Number of Bedrooms:
907-229-0065 4 [] Deep Trench I~i Shallow Trench [] Bed [] Mound [] Other:
Soil Rating: Total Depth from odginal grade:
LEGAL DESCRIPTION 6 GPD/F+ 5
Ft.
Block: TR F Lot: 3 Subdivision: Depth to pipe bottom from original grade:Gravel depth beneath pipe:
Fire Lake 2 Ft. 3 Ft.
Township: Range: Section: Fill added above original grade: Gravel Length:
* 2-4 Ft. 20 Ft.
Gravel width: Number of lines: I Distance between lines:
Well: [] New [] Upgrade 5 Ft. 1IN/A Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
Private 59 Ft. 59 Ft. 400 Ft2 ASTM 3034 PVC
Ddller: Date Ddlled: Static Water Level: Installer: Date Installed:
Sullivan Water Wells 9/16/2010 17 Ft. Dirty Deeds Const. 10/5/2010
Yield: I Pump Set at: I Casing Height Above Ground:
15 GPMI 48 Ft.I 2 Ft. TANK
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other:
T'~_ To Septic Absorption Lift Holding )ublic/Private Manufacturer: Capacity:
Tank Field Station Tank Sewer Line Orenco-Advantex ,~0(-20 1500 Gal.
Material: Number of Compartments:
Well >100' >100' N/A N/A >25' Fiberglass/Polyester (FRP) Two + Filter
SurtaceWater >100' >100' N/A N/A ~ / LIFT STATION
Size: Manufacturer:
Lot Line >5' >10' N/A N/A Gal. ORENCO
"Pump on' level at: "Pump cfr' level at: in. High water alarm at:
Foundation >5' >10' N/A N/A 48 in. 30 52 in.
Pump Make & Model Electrical Inspections performed by:
Curtain Drain None Noted 52 Rising Son Electric, Inc.
Remarks:
* Denotes 2" of rigid insulation installed over system BENCH MARK
Location and Description:
components in addition to the 2-4 feet of ground cover. Top of Well Sanitary Seal Cap
Assumed Elevation:
100.00 Ft.
Engineer's Stamp
Inspections performed by: TL Kimbrough Dates: 1st 10/5/10 @ 12:00
Development Services Department Approval
Conditional Approval Date: ~"*,' 49~,,¢"'~*; o* '
.~/
\
UPPER FIRE LAKE
~ ~ / \
~ \ RECOVERED
O ~
NO WELL OR SEPIIC '~
FOUND ON PARK ~ k ~ ~ %~,e~O~
PARCEL ~ ~ ~ ~ /
~ ~ ~j/ 1"= 50'
~ ~ LOT 1
PARK r m ~ ALTERNATE TRENCH
>10~ ~ ~TBAC
(b~se point) Q. ~ SUBD. PLAT
$ C4 38.5 37.1 ~ EXIS~N~C
'~' ~ ow~.u.~
~ C5 41.5 47.C
u M1 36.8 35.7 ~
~ M242.9 45.7 < CREEK
/
S~ 50.0 50.C
S2 51.0 53.~
FISH TCHER Y RD.__
5 T~CT "H"
ALASKA RIM ENGINEERING, INC. SlIE P LAN
P.O. Box 2749, PALMER, AK 99645
9131 E. FRONTAGE ROAD, SUITE 1 R EC 0 R D D WO.
PH: (907)745-0222 : FAX: (907)746-0222
EMAIL: akrim~alaskadm.com : WEB: www.~laskarim.com CONVENTIONAL SINGLE
FAMILY RESIDENTIAL
~;. c~ ,o~o
LEGAL DESCRIPTION: LOT 5, TRACT "F", FIRE ~KE SUBDIVISION ~' ......... "~
SCALE: 1 = 50' ~ FILE: 1000268_MOA ~ PAGE: 2 of 4 ~ ~2010
A B C D E
C1 27.1 5.5
C2 47.9 50.1
C3 46.0 48.4
C4 38.5 37.i
C5 41.5 47.C
M1 36.8 35.7
M242.9 45.7
S1 50.0 50.0
S2 51.0 55.6
F1 50.5 51.7
Wl 51.9 27.7
~ 4" PERFORATED PVC ---~
SOLID 4" PVC __/ =
· 2% SLOPE , CLEANOUT (typ)
20'
DRAINFIELD
PLAN VIEW
~-- MONITOR TUBE
PERFORATED PVC
HOLE 0RIENTAT/ON
(HOLES DO!~N)
SECTION X-X
GEOTEXT]LE --~
TRENCH DETAIL
N'0'I~ 2: ~ 0F 4-1~I~T OF ~ C0~
(OR EQ~) 0~R ~SO~ON ~N~. 0~
~ OF ~ ~S~O~ ~' (OR EQ.) ~Y
BE ~ FOR 0~ FOOT OF ~ CO~
~ TO A ~ OF ~0 ~C~S OF ~ON.
GROUND SURFACE
COVER
GROUNDWATER
ERMEABLE LAVEI~
TRENCH SECTION
t
3' EFFECTIVE DEPTH
t
P,~MOVF~ABLE CAP
NON-PERFORATED PVC
ABOVE SEWER ROCK
---- COUPLING
~--~111 I/IE ~_ ~;
MONITOR TUBE
DETAIL
Conventional Single Family Residential
SEPTIC SYSTEM RECORD DWG.
DE$O~,~,,O,'E~A~ LOL 3, Trac[ "F", Fire Lake Subd.
ENG~NC.
P.O. BOX 2749
PALMER, ALASKA 99645
PHONE: (907)745-0222
FAX: (907)746-0222
Not: %0 scale W0:10-00268
D~S,~. 9/10/10 CO.,'.~ED i0/5/10
ALASKA RIM ENGINEERING. INC. DATE DATF SHEET 3 OF 4
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP101160
Page 4 of 4
PID No. 051-133-30
2' RI])GI]) INSULATION
(TYP)
/-- 102,04 /
/ /- lo~.o7 ~, 8 /
_/_ / ~ lo~,o~ I1 I1 /
TOM = 100,00 --~ ~
m,m
8' RI1)GID INSULATION
(TYP)
Geo'tex'tile ~
Fo. brlc . _
99,48 ~? UrainFletct ~ ~99 35
96.88 96.29
PROFILE AS-BUILT
Scole: 1" = 10'
12/02/2010 20:43 FAX ~001/001
A1RG'rI¢ PUMP & WE:IL INC.
Jim Sullivan
PO Box 770197
E~le ~v~, AK ~77
(90~ 2~8-2~ 10
Pump Installation Log
Well Drilling Permit Number: SW
Parcel Identification Number:
Date of Issue:
Legal Description:Block:Lot: 3
Properg.' Owner Name & Address:
Pump Installation Date: t
Pump Intake Depth Below Top of Well
Pump Manufacturer's Name: Deml~stcr
Pump Model: ] 03-.50~'$V,.-~a,, 2.30'
Pump Size: hp //2--
Pitless Adapter Burial Depth: /
Pitle.~ Adapter ManufactureFs Name:
Pitless Adapter Installer: .t~--':_: - .
Well Disinfected Upon Completion? Yes
Method of Disinfection: Chlorine
Comnl¢llt $;
Pump Installer Name:
Arctic Pump & Well, Inc.
,4rcttc Pump & Wdl. Inc.
Page I of/
FROM : ANDERSON FAX NO. : 907 696 4282 No~. 22 2010 02:51PH P2
161
Well Log
PamfitNtanber: OSP ~o~so Date of Issue st~et;o~o
Date Started: 9/16/20'10 Date Complete& 9P16/2010
Property Description FIRE LAKE SUBDIVISION TRACT F Lot
$ ~lock NONE
Property Owner Name & Address:
Berehole. Data:
Soil Types Thickness & Water Strata
Casing Stickup
Overburden
Silt & Sand
Sand Grovel Silt
Parcel Identification Number: osaaas0?0o0
Is welt located at approved permit location? ~]Yes
Section: Town: Range:
DENNIS ANDERSON
t9~70 FISH HATCHERY RD. EAGLE RIVEI~ AK 99577
Method. of gh'illiog .., [k-'~.,air rotary,
Depth
From To
0 2
2 6
Casing type:
Wall thickness
Diameter
Liner type:
Diameter
0.25 inches
inches Total:
f~..¢able tool .........
feet
17 feet
inches Depth: feet
Casing stick-up above ground: 2 feet
Static Water Level (from top of casing)
Pumping Level: feet afar
I hours pumping gpm
Recovery ~ate 16 gpm
Method of Testing: Air
Well Intake Opening Type
~ Open End ~ Open Hole
~'~ Screened Start feet Stopped feet
{'"{ Perforatio~ S?,,,art .,,,. feet Stopped t~et
Grout Type: Bentonite dnj granular Volmc: ~0 Pounds
................................................................................................... Depth--.,.
Water Sample Results:
Attention:
44...-- Start , ,0 feet, Stopped ........ 44-.,,g-eet ......
Pump Intake Depth: feet
Pmnp size: lip brmtd nmne
Well disinfected upon Completion?
Method of disinfection CHLORINI~ 50 PPM
Comment~: BEDROCK ~ 60'. DRILLED TO 64' TO VERiFy
BEDROCK AND PULLED CASING BACK TO $$'
Well Driller:
Cole Sullivan
Sullivan Water Wells
P.O. Box 670~72
Chugiak. AK S~867
(907) 688-27S9
The properS' owner shall provide this Icg to DSD (onsite) and DNP.. with/n 30 days of completlon,
Mov 2B 2010 1:31PM RISIMG SOM ELECTRIC BO?-G22-Gg?? pm~e i
0'2'2-0777
October 22, 2010
Alaska Ram Engineering Inc.
Attn: Tim
P:O. Box 2749
Palmer, AK 99645
Re: 19170 Fish Hatchery Road - Eagle River, AK 99577
Dear Tim:
The liffc station at the above referenced property has been wired in accordance with NEC
and State/Local codes.
Thank you.
Kevin~S. HOrnbuclde, Owner
Adminlstrabor 'License Number 1284
Specialty Contractor License Number 27285
cc: file
SG_S
SGS Ref.# l 106666001
Client Name Anderson, Dennis G. Printed Date/Time 01/05/2011 11:24
Project Name/# Lot 3 Tr F Eagle River AK Collected Date/Time 12/20/2010 11:45
Client Sample ID Lot 3 Tr F Eagle River AK Received Date/Time 12/20/2010 12:50
Matrix Drinking Water Technical Director Stephen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container 1D Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00 ug/L EP200.8 C (<10) 12/21/10 12/27/10 KDC
Waters Department
Total Nitrate/Nitrite-N 1.62 0.100 mg/L SM20 4500NO3-F B (<10) 12/22/10 AYC
Microbiolog~ Laboratory
E. Coli Negative I 100mL SM20 9223B A 12/20/10 DLC
Total Coliform Nel~ative I 100mL SM20 9223B A 12/20/10 DLC
Phone (907) 7X5-0222
Fax {907) 746-0222
akr m@a aska::,m.co~
BOX 974~
/,.ias~a 99645
March 30, 2011
Mr. Jeff Poet
Municipality of Anchorage
On-Site Water and Wastewater
4700 Elmore Road
Anchorage, AK 99507
Tract F, Lot 3, Fire Lake Subdivision
Wastewater System Test Hole Elevations
Dear Jeff,
You communicated in your letter of February 23,2011 for additional information for the final
On-Site Wastewater Disposal System Inspection Report. You requested bottom of, original, and
final ground elevations of the test hole monitor tubes used for the installation of the above single
family residences wastewater disposal system (WWS).
Ground water elevations were monitored and logged per MOA regulations prior to installation of
the WWS. There was not any ground water infiltration into either of the test holes during the
monitoring stage as per our report. Additionally, the septic tank and the absorption trench were
installed at the maximum vertical elevation allowable (two (2) feet of soils cover with two (2)
inches of insulation installed.)
The wastewater installing contractor removed the monitor tubes after the monitoring of ground
water per permit documentation. This was done during the clearing and grubbing stage of
construction. Unfortunately, this was done before our personnel were informed and had the
opportunity to collect the test hole elevation data. The missing monitor tubes and final grading
negates the possibility of collecting and documenting the requested pre-construction elevation
datum.
All additional requests in your communication have been addressed and forwarded with this
letter.
Sincerely,
i/./"' '/~/!/'
k-~l~a~'l~eS- A. Lee~ ~.E.
AKRIM Project No. 10-00268
On-Site Water & Wastewater System Permit
OSP101160
05133307000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 EImore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number:
Tax Code Number:
Work Type: Initial
Permit Effective Dates: September 15, 2010 to
Design Engineer: ALASKA RIM ENGINEERING
Subdivision: FIRE LAKE
September 15, 2011
Site Legal Address: FIRE LAKE LT 3 TR F G:0554
Owner/Address: ANDERSON DENNIS G & SHARON A
18820 FISH HATCHERY RD EAGLE RIVER AK 995779208
Site Mailing Address:
18713 FISH HATCHERY RD, Eagle River
Lot Size in Sq Ft: 47190
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, Alaska 99507
www. muni.org/onsite
(907) 343;7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
/.:Lc~./,/U/I,-,., FOR A SINGLE FAMILY DWELLING
Parcel I.D. ~- / -' '~ '''': % ' "'~
Property owner(s)
Mailing address
Day phone
Zip Code
Site address
Legal description (Sub'd., Block & Lot)
.Zip Code
Legal description (Township, Range & Section)
Lot Size ~7., !~0 Sq. Ft.
Number of Bedrooms /------/
THIS APPLICATION IS FOR ([~ all that apply):
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
THIS APPLICATION IS AN:
Initial [~'
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Si,~ature of property ow-ner or authorized agent)
Permit/Rush Fees: 7 '-~ (7 Waiver Fees:
Date of Payment: ~ / ~ - ? O Date of Payment:
Receipt Number: I '~ ~ ~' // Receipt Number:
(Rev. 11/05)
Phone (907) 745-0222
Fax (907) 746-0222
akrim@alaskarim.com
P.O. Box 2749
Palmer', Alaska 99645
September 10, 2010
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Programs
4700 South Bragaw Street
Anchorage, Alaska 99519-6650
Subject:
Lot 3, Tract "F", Fire Lake Subdivision
Septic System Design and Well Permit Application
Impacts to Adjacent Lots and Water Bodies
Dear On-Site Services Engineer:
The owner of Lot 3, Tract "F", Fire Lake Subdivision intends to construct a new well and a four-
bedroom wastewater system on the lot. We are therefore requesting a permit be issued for
the construction of a new well and septic system to accommodate the existing home. The
attached Site Plan and backup documentation identify the location and configuration of the
proposed septic system along with the alternate site
No existing wells or septic systems are closer than 100 feet from the proposed well or septic
system. The National Wetlands Inventory states there are no wetlands on Upper Fire Lake.
Therefore, there are no wetlands closer than 100 feet of the proposed wastewater system. The
drainage arrows are shown on the site plan showing the grade and direction of flow on the lot
to the North. The drainage pattern will not be changed as a result of the project.
The above lot East and West property lines, as well as the adjoining Park Lot to the West, are
inhabited by natural Birch, White Spruce, and Green Alder. The stream and lake edge are
populated with Wild Roses and other smaller natural indigence foliage cover. The center of the
lot is lawn grasses indigence to Alaska. The lawn is mowed and maintained.
Page ! of 3
Engineers · Planners ° Surveyors
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
Lot 3, Tract "F", Fire Lake Subdivision
September 10, 2010
1. A foundation cleanout shall be installed one to four feet from the building foundation.
Two deanouts are required between tank and the drain field on gravity flow systems.
2. Final grading over the tank shall be such that a positive slope exists away from the septic
tank.
DRAIN FIELD CONSTRUCTUION:
1. The drain field shall be constructed to the dimensions shown on the design. The bottom
of the trench shall be within 2 inches of level.
2. Distribution piping must be placed level with perforations down atop a level bed of
drain field rock. Rock should then be placed over the pipe to provide a minimum of 2
inches of cover.
3. A silt barrier or geo-textile fabric must be placed between the drain field rock and the
natural soil backfill.
4. Monitor tubes must be 4 inches in diameter and installed at then locations shown on
the design. The portion below the distribution line must be perforated. The portion
above the distribution line must be solid.
5. Contractor shall verify the septic tank and drain field are a minimum 100 feet away from
any private wells in the area, 150 feet from a Class "C" Well or 200 feet from a Class "A"
or "B" community well.
6. Direct bury insulation must be placed over the distribution system if less than 3 feet of
backfill depth is available. Finish grade over the trench must be mounted to prevent
settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum of 2 feet of natural unsaturated and 4' of accepting soil is required below
the drain field rock for a 5 foot wide trench. Contractor shall verify this condition prior
to placement of the rock. All pockets of unacceptable materials must be removed and
replaced.
MATERIAL SPECIFICATION:
1. Septic tanks must be constructed by a municipality approved septic tank manufacturer.
2. The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Page 2 of 3
Lot 3, Tract F, Fire Lake Subdivision
September 10, 2010
If the system is constructed with our design the following statements apply:
1. The system, if constructed as designed, will have no adverse impact on the wells in the
area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing septic
systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve space,
either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Charles A. Leet, P.E.
Page 3 of 3
DESIGN FACTORS:
FOUR (4) BEDROOM HOUSE
PERC. RATE 1-5 ]~fIN/INCH
AWWTS APPLICATION RATE 6 GPD/SF
SYSTEM REQU1RMENTS:
FIVE (5') FEET WIDE TRENCH SYSTEM
1.500 ADVANTEX SEPTIC TANK AND COFFIN
THREE (3') FEET DRAINFIELD ROCK
(4 BEDROOMS X 150 GPD)/6 GPD/SF (Application Rate) =100 SF ABSORPTION AREA
100 SF/5 FT * .58 (RF) = 11.6 LF TRENCH LENGTH
O
O O
CONSTRUCT A GRAVITY FLOW ABSORTION TRENCH ~0' LONG X 5' WIDE X 3'
EFFECTIVE DEPTH. FLOW LINE ELEVATION IN TRENCH TO BE 2' BELOW 0RIGINAL
GROUND SURFACE. PROVIDE 4' COVER OVER SEPTIC TANK AND 3' COVER OVER
ABSORPTION TRENCH.
NATURAL
BACKFILL
GEOTEXTILE FABRIC
'4" PERFORATED PVC
-.5" - 2.5" SEWER ROCK
TYPICAL 5' WIDE TRENCH SECTION
NOTE:
Grade area ove trench to drain away.
Minimum 6" separation from bedrock.
Minimum 4' separation from groungwater.
Minimum 100' separation from wells in the area.
minimum 100' separation from surface water.
Single Family Residential
SEPTIC SYSTEM DESIGN
Lot 3 Tract "F"
, , Fire Lake Subdivision
RECORD DRAWING
This record drawing represents the as-constructed condition of the improvements
documented above. Based on periodic visual observation and information
obtained from the installer, this data appears reasonable and represents that the
project was constructed in general conformance with current 18 AAC 72
regulations and ADEC policies.
Not to scale WO: 10-00288
ALASKA ~M g~l~g~. INC. ~TF ~Tf00/00/09 SHEET 1 OF 2
~ON1TOR TL~E A?
DRMNFIELD
PLAN VIEW
I
PSRFOI~T~D PVC
HOI~ OE1EMTA3~ON
SECTION X-X
TRENCH DETAIL
]~ ~ ~ ~F ~-~ OF ~ ~
(OR ~UW~ ~ ~oN ~. o~
~ ~ A M~ ~ ~ m~ OF m~o~.
4' MiN.
B' g~ DgPTH
E REMOVEARU~ CAP
NON-PERFORATED PVC
ABOVE 9EWER ~CK
CO~G
~ ~11 Ilk ~
~ONWOg
DETAIL
TRENCH SECTION
COnventional Single Family Residential
SEPTIC SYSTEM RECORD DWG.
o.~.,.~o~- Lot 3, Tract "F", Fire Lake Subd.
~W¢.~,~ ~.~ P.O. BOX 2749
PALMER, ALASKA 99645
PHONE: (907)745-0222
FAX: (907)746-0222
Not to scale WO: 10-00~B0
ALASKA RIM ENGINEERING, INC, ~iE ~TF SHEET 2 OF ~
~EC,~RDING DISTRIC~ . - ,/ /
UPPER FIRE LAKE ,-
/ /~ HICH WATER ~
. / / ~ T~E l~ ........ 5/8" REBAR
~ / / / A PROPOSEu
~ I ~APPROX GLO ' / WELL
~"' ~ 1500 GALLON '
NO WELL OR SEPTIC ~ ~V/~ ADVAN~X // ~ _../~LOT 1
FOUND ON PARK ~ ~SEPTiC SYS~M ~ /~ /~
~ ~ R MILLER
11.8 ~~~ ~20 LONG x 5 WIDE-- ~Y~ r. ~- ·
TEST HOLE ~ ~ ~ ABSORPTION TRENCH ~8~ ~ ~ ( Z
P~T
, ,~ .. ~ ~ . 2006-150
.~ ~ J EXIS~NG TANK/SAS ~ ~ ~ ~ ~
LEGEND: ~:~l~ k k ~ P~T 2006-150
(M)=MEASURED DATA ~ ~lt?~'* N C~EEK
(R)=RECORD DATA 0 mll~ ~ ~
W.D.=WlTNESS DISTANCE ~ ~J ~ / ~ .... .~ ~ ~ ~m ~ ~ ~ RECO~REDk 2 ~/2"
C/O=CLEAN OUT ~ ~J /~ ~~ LU'~' ~ ~ ~ ALUMINUM MONUMENT
FCO=FOUNOATION CLEAN OUT ~l . .~' ~ ~ ~ ~LS 6918, 2006
MT=MONITOR TUBE ~ > I/.~' ~ ~
sv=s~m~c V~NT ~? :~ ~&' ~ ~ .~
~ /~ z.~~'W ~ 65~j~ EXISTING WELL
FISH HA TCHER Y RD.
X TRACT "H"
THIS D~WING REPRESENTS THE AS-~ONST8U~TED ~ONDmON OF THE IMPROVEMENTS DOCUMENTED ABOVE. BASED ON
PERIODI~ VISUAL OBSERVATION AND INFORMATION OBTAINED FROM THE INSTALLER, THIS DATA A~8S R~SONAB~E AND
REPRESENTS THAT THE ~ROdECT WAS CONSTRUCTED IN GENIAL ~ONFORMAN~E WITH CURRENT ~C 72 ~EGU~TION AND
ADEC ~OLICIES.
P.O. Box 2749, PALMER, AK 99645
9131 E. FRONTAGE ROAD, SUITE 1 DRAWING
EMAIL: akrim~alaskarim.com : WEB: www.~laskarim.~om CONVENTIONAL SINGLE
LEGAL DESORIPTION: LOT 3, TRAOT "F", FIRE ~KE SUBDIVISION ~": ......... ~"~
NOTES:
1. NO PRELIMINARY FIELD WORK PERFORMED THIS DATE .
2. THE FINAL SEPTIC AREA IS TO BE DETERMINED IN THE FIELD WITH THE
VERIFICATION OF SOILS AND NEIGHBORING WELLS.
.3. THE FINAL DWELLING LOCATION AND FINISHED FLOOR ELEVATION IS TO BE
I DETERMINED IN THE FIELD BY THE CONTRACTOR.
I 4-. THE FINAL WELL LOCATION TO BE DETERMINED IN THE FIELD WITH THE
VERIFICATION OF NEIGHBORING SEPTIC.
i 5. BUILDING SETBACKS DERIVED FROM M.O.A. SETBACK REQUIREMENTS. IT IS THE USERS
~.~.~. RESPONSIBILI'm~' TO ENSURE THAT SAID SETBACK IS THE MOST CURRENT AND RESTRICTIVE.
· ..,. ....... .....~" \ ~,-- ~ ,. --
/
i EXlSTIN j '-.
EXCLUSION NOTE: IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER, PRIOR TO CONSTRUCTION, TO VERIFY PROPOSED
BUILDING GRADE RELATIVE TO FINISHED GRADE AND UTILmES CONNECTIONS, AND TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
THIS DRAWING REPRESENTS THE AS-CONSTRUCTED CONDITION OF THE IMPROVEMENTS DOCUMENTED ABOVE. BASED ON
PERIODIC VISUAL OBSERVATION AND INFORMATION OBTAINED FROM THE INSTALLER, THIS DATA APPEARS REASONABLE AND
REPRESENTS THAT THE PROJECT WAS CONSTRUCTED IN GENERAL CONFORMANCE WITH CURRENT AAC 72 REGULATION AND
ADEC POLICIES.
ALASKA RIM ENGINEERING, INC. AREA MAP
P.O. Box 2749, PALMER, AK 99645
9131 E. FRONTAGE ROAD, SUITE 1 DRAWING
PH: (907)745-0222 : FAX: (907)7<6-0222 ~~,'~,~
EMAIL: akrim@alaskarim.com : WEB: www.alaskarim.com CONVENTIONAL SINGLE ........................
FAMILY RESIDENTIAL ~/~J~;~t ~/~. CE 10480 .%~
.... ~ ~4~' ....... "~
LEGAL DESCRIPTION: LOT 5, TRACT F, FIRE LAKE SUBDIVISION ~¥~:'-""::'*\-~
SCALE: 1" = 100' I I PAGE: 2 of 2 I ®2o~o
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
ALASKA RIM ENGINEERING, INC.
01,:,1 Frontage Road, Palmer, Alaska 99(345
Phone: 907-743-0222 Fax: 907-74(3-0222
SOILS LOG - PERCOLATION TEST
Performed For: Dennis Anderson Date:
Legal Description: Lot 3, Tract "F", Fh'e Lake Subdivision
Township, Range, Section:
Parcel ID#: Project #:
TEST HOLE # 2 ]
OB/(X~
WELL GRADED SANDS W/
GRAVELS. DRY. CLEAN
SOME FINES (SW)
7/25/2010
10-00268
Type of Test: [] Percolation [] Visual
Slope Site Plan
...: 2._5.%.
BOH
x,V:k$ GROI_rND ~2-kTER
ENCOUNTERED?
IF YES. AT WHAT DEPTH'?.
DEPTH OF WATER
AFTER MONITORING?
DA~:
NO
NONE
8/5/10
o : : : : < 2%: : : : : :
20
COMMENTS:
Test Hole Presoaked Pri~ to Testing
Date Reading G~ss Thue Net Thne ~p~'to Net Drop
Water .
7/26/10 1 0905 10.75
2 0915 10 1.375 9.375
3 0915 11.875
4 0925 10 1.875 10.0
5 0925 11.625
6 0935 10 1.875 9.75
PERCOLATION RATE: 1.03 (MIN/INCH) PERC. HOLE DIA. , 6 (INCHES)
TEST RUN BETWEEN: 3.5 FT. and 4.5 FT.
Wastewater application rate per ADEC 18 AAC 72 Table C = 1.2 gpd/sq, ft.
TEST PERFORMED BY: T.L. KIMBROUGH: I, CHARLES A. LEET CERTIFY THAT THIS TEST WAS PERFORMED
IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUDELINES IN EFFECT ON THIS DATE: ~/,ZG //2~ t/°
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
ALASKA RIM ENGINEERING, INC.
01,:,1 Frontage Road, Palmer, Alaska 99(345
Phone: 907-743-0222 Fax: 907-74(3-0222
SOILS LOG - PERCOLATION TEST
Performed For: Dennis Anderson Date:
Legal Description: Lot 3, Tract "F", Fh'e Lake Subdivision
Township, Range, Section:
Parcel ID#: Project #:
TEST HOLE # 2 ]
OB/(X~
WELL GRADED SANDS W/
GRAVELS. DRY. CLEAN
SOME FINES (SW)
7/25/2010
10-00268
Type of Test: [] Percolation [] Visual
Slope Site Plan
...: 2._5.%.
BOH
x,V:k$ GROI_rND ~2-kTER
ENCOUNTERED?
IF YES. AT WHAT DEPTH'?.
DEPTH OF WATER
AFTER MONITORING?
DA~:
NO
NONE
8/5/10
o : : : : < 2%: : : : : :
20
COMMENTS:
Test Hole Presoaked Pri~ to Testing
Date Reading G~ss Thue Net Thne ~p~'to Net Drop
Water .
7/26/10 1 0905 10.75
2 0915 10 1.375 9.375
3 0915 11.875
4 0925 10 1.875 10.0
5 0925 11.625
6 0935 10 1.875 9.75
PERCOLATION RATE: 1.03 (MIN/INCH) PERC. HOLE DIA. , 6 (INCHES)
TEST RUN BETWEEN: 3.5 FT. and 4.5 FT.
Wastewater application rate per ADEC 18 AAC 72 Table C = 1.2 gpd/sq, ft.
TEST PERFORMED BY: T.L. KIMBROUGH: I, CHARLES A. LEET CERTIFY THAT THIS TEST WAS PERFORMED
IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUDELINES IN EFFECT ON THIS DATE: ~/,ZG //2~ t/°
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
ALASKA RIM ENGINEERING, INC.
c '~ 1~. "
01,:,1 Frontage Road. Palmer, Alaska 99(345
Phone: 9(37-745-0222 Fax: 907-746-0222
SOILS LOG- PERCOLATION TEST
Performed For: Dennis Anderson Date:
Legal Description: Lot 3. Tract "F". Fire Lake Subdivision
Township, Range, Section:
Parcel ID#: Project #:
TEST HOLE# I l
OB/OG
WELL GRADED SANDS W/
GRAVELS. DRY. CLEAN
SOME FINES (SW)
7/25/2010
10-00268
Type of Test: [] Percolation [] Visual
Slope
'". 2'-5!o'
Site Plan
BOH
WAS GROUND WATER
ENC(XrNTERED?
IF 'xES. AT \~TL~kT DEPTH?.
DEPTH OF WATER
AFTER MONITORING?
DATE:
Sl ::
NONE
8/5/10 e
20
COMMENTS:
Test Hole Presoaked Prior to Testing
Date Reading Gross Tm)e Net Tm~e D._epth to Net Drop
Water
7/26/10 1 0900 11.125
2 0910 10 1.25 9.875
3 0910 11.375
4 0920 10 1.625 9.75
5 0930 11.875
6 0940 I0 2.0 9.875
PERCOLATION RATE:. !...01 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 3,5 FT. and 4.5 FT.
Wastewater application rate per ADEC 18 AAC 72 Table C = 1.2 gpd/scl.' ff ,
TEST PERFORMED BY: T.L. KIMBROUGH: I. CHARLES A. LEET CERTIFY THAT THIS TEST WAS PERFOR~D
IN ACCORDANCE WITH ALL STATE AND IVRrNICIPLE GUIDELINES IN EFFECT ON THIS DATE: ?/~/,/~/g)
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
Subject: Lot 3, Tract "F", Fire Lake Subdivision
September 13, 2010
GENERAL:
1. The scope of this project includes the procurement and placement of a new (AWTS Class
III) 1,500 gallon Advantex septic tank and treatment system at the location shown on
the Site Plan. Work also includes the construction of a new 20' long X 5' wide X 3'
effective depth distribution trench (see attached calc sheet) at the location shown on
the Site Plan. The distribution line will be placed 2.0' below the existing ground surface.
Total depth of the trench will be 5.0' below existing ground surface. The new
absorption trench and septic tank must be placed a minimum of 100' from all private
wells and any surface water in the area as well as 10' from any water service line
proposed for the lot. A minimum of 3' of cover is required over the absorption trench
and 4' of cover over the septic tank.
2. Construction shall be in accordance with the approved site plan, design drawings,
Municipal Permit with any special provisions or conditions, and all applicable State and
Municipal Wastewater Disposal Regulations.
3. The contractor will be responsible for obtaining all underground utility locates and for
the layout of the septic system and verification of the location of all property lines and
easements.
4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading
areas subsequently depressed from soil settling. Property owner shall be responsible
for vegetation of affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the Municipal
Development Services Department Building Safety Division Onsite Water and
Wastewater Program for system installation. Owners installing their own systems must
receive prior approval from the Onsite Water and Wastewater Program before
beginning installation.
SEPTIC TANK INSTALLATION:
1. A new (AWTS Class III) 1,500 gallon Advantex septic tank and treatment system must be
purchased from Anchorage Tank and Welding and installed at the location shown
2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction
shall have two 4" cleanouts for pumping as well as vault lid for pump service.
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank.
4. Tanks installed without 4' of cover shall have a minimum of direct burial insulation.
5. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
Page 1 of 3
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
Lot 3, Tract "F", Fire Lake Subdivision
September 13, 2010
1. A foundation cleanout shall be installed one to four feet from the building foundation.
Two cleanouts are required between tank and the drain field on gravity flow systems.
2. Final grading over the tank shall be such that a positive slope exists away from the septic
tank.
DRAIN FIELD CONSTRUCTION:
1. The drain field shall be constructed to the dimensions shown on the design. The bottom
of the trench shall be within 2 inches of level.
2. Distribution piping must be placed level with perforations down atop a level bed of
drain field rock. Rock should then be placed over the pipe to provide a minimum of 2
inches of cover.
3. A silt barrier or geo-textile fabric must be placed between the drain field rock and the
natural soil backfill.
4. Monitor tubes must be 4 inches in diameter and installed at then locations shown on
the design. The portion below the distribution line must be perforated. The portion
above the distribution line must be solid.
5. Contractor shall verify the septic tank and drain field are a minimum 100 feet away from
any private wells in the area, 150 feet from a Class "C" Well or 200 feet from a Class "A"
or "B" community well.
6. Direct bury insulation must be placed over the distribution system if less than 3 feet of
backfill depth is available. Finish grade over the trench must be mounted to prevent
settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum of 2 feet of natural unsaturated and 4' of accepting soil is required below
the drain field rock for a 5 foot wide trench. Contractor shall verify this condition prior
to placement of the rock. All pockets of unacceptable materials must be removed and
replaced.
MATERIAL SPECIFICATION:
1. Septic tanks must be constructed by a municipality approved septic tank manufacturer.
2. The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Page 2 of 3
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
Lot 3, Tract "F", Fire Lake Subdivision
September 13, 2010
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid),
ASTM F810 or H.D.P.E. (perforated, but not solid), and ASTM D2662 or A.8.S.
(perforated and solid).
3. Insulation shall be at least 2 inches thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Ferco, or
equal).
5. A permeable geo-textile fabric (Typar, Mirafi, or equal) must be installed between the
final drain rock layer and the native soil layer.
6. All drain rock shall be .5 inch to 2.5 inch in diameter with less than 3% passing the #200
sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections must
be conducted under the supervision of a professional engineer registered in the State of
Alaska. The first inspection must be conducted after the excavation of trenches, beds,
or pits and before the installation of any gravel. A septic tank may be set in place, but
may not be backfilled.
The second inspection must be conducted after the placement of the geo-textile fabric,
gravel, distribution piping, standpipes, cleanouts, and insulation. No backfill should be
in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes for use
in preparing the certified as-built of the completed system.
Charles A. Leet, P.E.
Alaska Rim Engineering, inc.
Page 3 of 3
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT
MEMORANDUM OF UNDERSTANDING
BETWEEN MUNICIPALITY OF ANCHORAGE
AND
THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Memorandum of Understanding agree as follows:
1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality
grants permission to Owner to utilize and operate an Advanced Wastewater
Treatment System (AWWTS), described as /'~ ~//~;t ~,-t -~/--G.~' located
2. Definitions.
A. Alteration. Any change to the design or function of an AWWTS that
Includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design. Prior to
performing any alterations to an AWWTS the owner must obtain a
Wastewater Disposal System Construction Permit from the Municipality
pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65.
B. Certificate of On-Site Systems Approval. An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with AMC 15.65.
The term begins on the date of approval by the Municipality of the installed system and
shall continue while the AWWTS system is in use or operational or until the property is
sold or title is transferred by owner and a new certificate of On-Site approval is issued to
the new owner or transferee of the property.
5. Alterations~ Installation and Removal of Additional Equipment. Owner agrees
not to make any alterations, removal of parts or additions to the AWWTS without a
Construction Permit from the Municipality.
6. Maintenance and Repairs.
A. Throughout the term of this Memorandum of Understanding, the Owner shall
maintain AWWTS in good repair. In addition, it shall be the responsibility of the
Owner during the term of this Memorandum of Understanding, and any extensions or
renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2)
maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs.
Further, Owner agrees to comply will all applicable ordinance, laws, regulations,
rules and orders for the AWWTS.
B. Owner agrees to provide the Municipality a written schedule of routine
maintenance and repairs which have been performed on the system pursuant to the
terms and conditions contained in the Owner's AWWTS Operating Permit. This
schedule shall be submitted to the Municipality annually upon the renewal of the
permit. The schedule of maintenance and repair contained in the Owner's AWWTS
Operating Permit is:
/
C. Owner acknowledges that the fine schedule for failing to maintain and repair an
AWWTS are codified in AMC 14.60.
Ovmer:
Anchorage: Purchasin~ Officer
C. Any attempt to amend, modify, or change this contract by either an
unauthorized representative or unauthorized means shall be void.
9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of
Understanding shall be brought in the Superior Court for the Third Judicial District of the
State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and
obligations of the parties under this Memorandum of Understanding.
10. Severability. Any provisions of this Memorandum of Understanding decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining provisions
of the Memorandum of Understanding.
OWNF..R: , ~~.~
By:..~k'~'-~ .~?~ff,~ ~ By:
nate~ ~~; Date:Title:
STATE OF ALASKA )
) SS.
THIRD JUDICIAL DISTRICT )
MUNICIPALITY:
,
The foregoing instrument was acknowledged before me this /'7 clhy of
20(o',byD~'_r~,~,.~ ~c.-,,~. ~,~.1~,...~ ,the
NOTARY PUBLIC FOR ALASKA
My Commission expires: z.., t >¢-~ d;