Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 1H LT 23ARabbit Creek View & Heights Biock 1H Lot 23A #020-551-02 _ , o Adv.7nccd TrvvGrnent Skstem Ile GARNESS ENGINEERING GROUP, Ltd ° 'c.+arYn ENGINEERING o SALES o CONSULTING — January 25, 2019 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650. Anchorage, AK 99519-6650 (907) 343-7904 Ref: Rabbit Creek View & Heights S/D; Block 1 H, Lots 23A & 24A (16400 Carl Street, Anchorage, AK) Memo concerning converting CAT III AWWTS to CAT II AWWTS septic system To whom it may concern: The permitted septic system was installed on the referenced property on 9/6-7/2010 and was started up shortly after that. ARM Septic Services, LLC checked the monitoring tubes in the drainfield on 9/11/2018 and found them to be dry. In order to simplify the overall operation and maintenance of the system, we are proposing that this unit be permanently configured as a CAT I I system. Our justifications are as follows: • The receiving soil had percolation rates of 120 minutes per inch. Given this percolation rate, a 0.5 gpd/sq.ft. application rate is required for a Cat III system and a 0.3 gpd/sq.ft. application rate would be required for a Cat II system. There is also 4+ foot of MOA approved sand filter below the drainrock for this drainfield. We are proposing that Quanics Aerocell system be converted to a Cat II configuration and that after the effluent passes through 2+ feet of MOA approved sand filter, the effluent should meet Cat III effluent quality levels. Since this system has 4+ feet of MOA sand filter above the native, insitu soils, it is our opinion that the Quanics Aerocell system should be able to be used in a CAT II configuration and that the required 0.5 gpd/sq.ft. application rate has been met at the point of 2' below the bottom of the drainrock because of the MOA sand filter. The residences on this property have a total of 3 bedrooms, so 900 sq./ft. of absorption area is required for a CAT II system with a 2+ feet sand filter (450 gpd / 0.5). The existing 2010 drainfield has 966 sq./ft. of absorption area. In short, the drainfield meets the Cat III requirements (Cat II configuration + 2 foot sand filter) absorption area requirements. At this time, we request that your department approve a CAT II configuration be used at the referenced prope Upon your concurrence, we will have ARM Septic Service, LLC, either leave the Jandy valve a t for in the discharge position; or have them completely remove the actuator and leave the valve, the\open position. We will also have them place a CAT II sticker on the control S P.E. M.S. so l � AC 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Municipality of Anchorage = N• Development Services Department Building Safety Division On-Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number. OSP 101 178 PID Number: 020-551-02 Nome: MARY ELDRED Y Wastewater System: ❑ New ■ Upgrade Address: 16400 CARL STREET *ANCHORAGE, AK ABSORPTION FIELD Phone: No. of Bedrooms: (907) 441-8499 3 ❑Deep Trench ❑Shallow Trench ❑Bed ■ ound❑ Other �om LEGAL DESCRIPTION Soil Rating: f I � original grade: tot Depth fr SEE DWG. GPD/Sq. Ft. Ft. Block: Lot: - Subdivision: Depth to pipe bottom from original grade: Grovel depth beneath pipe: 1H 23A & 24A RABBIT CREEK HEIGHTS SEE DWG. Fl. 0.52 Ft. Township- Range: Section: Fill added above original grade: Gravel length: — — — SEE DWG. FL 46 Ft. WELL: ❑ New ❑ Upgrade Gravel width: 21 Number of lines: 4 Distance between linea 5 Ft, Ft. Classification (Private, A.D,C): Total Deat Caead Tw(BEDROCK) Total absorption area: Pipe material: Ft. FL 966 sa. Ft. D 3034/ F-810/SCH 40 Static Water Laval: FL Installer: WILCO CONTRACTORS Date installed: 9/6-8/2010 Driller. \ '�� Dote Drilled: � Yield: Pump Set At: Casing Height Above Ground: TANK GPM Ft. Ft SEPARATION DISTANCES ❑ Septic ❑ Holding ■ S.T.E.P. O Other* To $eptic Absorption Lift Holding Public/Private Manufacturer. GREER copacity in gallons: 1500 From Tank Feld Station Tank sewer Lines Well 100'+ 100'+ 100'+ — 25'+ Material: STEEL Number of compartments: 2 Surface Water 100'+ 100'+ 100'+ - - LIFT STATION Lot Line 5'+ 10'+ 10'+ _ — size in gallons: 1500 Manufacturer: GREER QUANICS 'Pump on' lave! at: 'Pump off' level at: High water alarm at: Foundation 5'+ 10'+ 10'-1- — — TIMER TIMER 1 44" Pump Make dt Model Electrical Inspections performed by: Curtain Drain — 50'+ — — — P—FS-41T I ED'S ELECTRIC Remarks: THIS IS A QUANICS AEROCELL SYSTEM BENCH MARK (xallon and Description: OLD HOLDING TANK WAS DECOMMISSIONED. TOP OF WINDOW TRIM, SW SIDE OF HOUSE TOPSOIL AND SEEDING WILL BE DONE IN THE SPRING 2011. Assumed Elevation: 104.26 Ltd. Inspections performed by: GEG, Dates: 1st 9/6/10 ENGINEER'S SEAT. 4�Qoo pp 2nd 3rd 9/7/10//10 Development Services Department Approval o° 49 -VPA Gt/ 0 " �_ ,p Conditional approval: Date: i! 0 .......... ...... 0 �•• -• . ••-••-•••••Q p� .J f r A. G ness• N pp� CE-79 �p Reviewed and approved by: _ Dater vtiOdPraf6sslall (Rev. 4/06) QQQ�p0p4 (0- 0 0 Z J m I z � C J a) m I A 00 co to W0 Om q W Z9'99 ® �131V'MQNnmjo Z�'Z9 = 31OH 1S31 30 W01108 30 NOUVA313 3AUV132J S3d0\ ZC'S6 ONVS 30 d01 ('OnV') LO°96 = 3N11 ouneI2i1S10 30 id3AN1 Sad S ' l LOZ 30 ONI2JdS 3H1 NI (13033S 0RJOV'3 �J311I) (INV0311OSd01 39 01 (MUNMM +9C'96 = > LA 00 00 NOIlV1(1SN1J 00 30V89 IVNIJ 00 1W 74 m z t ^� c� y )INYI d31S ividm d330 -VZ•62 = y `+ 1331S 3Of1VO O l NOIIV'9 009L ONne 30 12J3AN1 m '038 030Nnon 69'99 =E3 in0 m 30 d01 NO S11S NMdl 30 d01 iINn 11300213V b PPP}j - o '3AIVA k(INV WN831Nl /M IS 0 11300bDV SOINvno OS9 O 1 V r l f^1 C1, 69'99 =131N1 ANdl 30 d01 0 m y .-,o VoLSS-0V0 ���D000��oo �d�BW(1N DI ���db'd DNIAIvVN(I JLllflg-SV +0976 =30"O I`dNl3 8L L LO LdSO :thio( 1N ilMdld Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101178 O20551O2OOO Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: September 17, 2010 to September 17, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: RABBIT CREEK VIEW & HEIGHTS Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 1H LT 23A G:3340 Owner/Address: ELDRED MARY R 16400 CARL STREET ANCHORAGE AK 995165501 Site Mailing Address: 16400 CARL ST, Anchorage Lot Size in Sq Ft: 21869 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: A copy of the state stamped ingress/egress agreement to be submitted before the inspection report is approved. Received By: Issued By: Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERHIT APPLICATION FOR A SINGLE FAHILY DWELLING ~95,~0 /011 7~ Parcel I.D. 020-551-02 Day phone 441-8499 Property owner(s) MARY ELDRED Mailing address 16400 CARL STREET * ANCHORAGE, AK * 99516 Site address 16400 CARL STREET * ANCHORAGE, AK Zip Code 99516 Legal description (Sub'd, Block & Lot) RABBIT CREEK HEIGHTS S/D; BLOCK 1H, LOTS 23A & 24A Legal description (Township, Section & Range) N/A Lot Size ~- [~ ~ C~ Sq. Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR ( [] all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS August 23, 2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for Rabbit Creek Heights S/D; Block 1H, Lots 23A & 24A, To whom it may concern: The existing 3 bedroom house is served by a private well and a holding tank. We are proposing to install a new 1500 gallon S.T.E.P. tank with Quanics controls/floats and a bed type drainfield. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the drainfield is a 5-10% percent slope running south to north. 5. DRAINFIELD WIDTH VARIANCE: Due to the size and elevation of the proposed system, we are requesting a variance in drainfield width. We are proposing to install a 20 foot wide bed so that the resulting 3:1 slopes can be contained on the property. We are unaware of any adverse affects that this waiver would create for adjacent wells or septic systems. 6. DRAINFIELD DESIGN VARIANCE: We are proposing to remove the organic layer and build up the drainfield with MOA approved sand as required to meet the 6 foot separation distance to impermeable soils. We are unaware o?any adverse impacts this installation would have on adjacent wells or septic systems. If you have any,~l~'estions, please contact us at 337-6179° Thank you for your assistance. Presic m. So 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com I I'--- I XHTS I _~ I RABBIT CREEK HEIG BLOCK 2H, LOT 1 I -- I bOi I ~.___...i .~ I -J zl~'' SCALE: I Q:::: ' / I x ~":~oo' ~ I < / I 0 I RABBIT CREEK ~IGHTS, I /i I BLOCK 2H, LO~ 16 I /] I I I '~ I I ~~ I / Xl I / cu.~.,u ~.~ ~ I ........... j x L ~--. ........... ~*~*~ ..... ~ i x ,-- ....... ~S ~S ~ , ~ SEPTIC v ~/ / X ~ I MARINO DRIVEXx / ', x . , :---.. ~BBIT CREEK HEIGHTS,I ~BBtT CREEK HEIGHTS RABBIT CREEK BLOCK 4H, LOT ~ RABBIT CREE~ HEIGHTS, BLOCK 5H, LOT 39 HEIGHTS, ~BBI~ CREEK HEIGHTS BLOCK 4H~ LOT/5 ~ ~ BLOCK 5H, ~ LOT 38 ~ BLOCK 4H, LOT 4 / / X ~ /// PREPARED FOR: PHONE ..... '. ,~,, o~c~,~,o~: ' ' ~w, ~: ~ 'tL tF:-P:: .' ~PE OF WORK: ~'~: . . SITE PLAN 8/19/2010 Ltd. HAS A 7 PAGE SPECIFICATION GEG, DESIGN CRITERIA: DRAINFIELD DESIGN: LETTER THAT PERTAINS TO THIS DESIGN° NUMBER OF BEDROOMS: .3 MAXIMUM DEPTH: LIMITED TO TO OBTAIN A COPY OF THE LETTER GALLONS PER DAY (GPD): 450 REMOVAL OF ALL ORGANICS CONTACT GEG. BY PROCEEDING FORWARD PERCOLATION RATE/S: '120 MIN/IN WIDTH: 20' , WITH THIS INSTALLATION, THE ENGINEER, PROPOSED APPLICATION RATE: *0.5 LENGTH: 45' WELL DRILLER, CONTRACTOR AND MINIMUM DRAINFIELD SO.FT.: 900 M-O.A. APPROVED SAND FILTER: AS PROPERTY OWNER AGREE THAT THEY *ADVANCED TREATMENT SYSTEM REQUIRED TO BE 4' ABOVE HIGHEST HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND ORIGINAL GRADE ENCOUNTERED CONDITIONS OUTLINED. EFFECTIVE: 0.5' REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 900 ~;g APPX. LOCAT,ON-'- / SHED / / L PROPOSED 1500 GALLO~ 650 AEROCELL UN,T W/ %,~, ,NTERNAL ,ANDY (TO ~E ~ ~ NOTE: TESTHOLE S~ER LINE TO BE TO BE BACKFILLED REPLUMBED DURING AND COMPACTED CONSTRUCTION TO WITH NATIVE EXIT HOUSE ON NOTE: CONTRACTOR SHALL HAVE 100' WELL RADIUS AND WEST LOT LINE F~GGED BY a REGISTERED ' / PROFESSIONAL ~ND SU~OR PRIOR TO ~ CONSTRUCTION MARINO DRIVE t MARY ELDREDI907-441-8499 2 Of 5 ~'V~; LEGAL DESCRIPTION: ~D~WN BY: RABBIT CREEK HEIGHTS S/D; BLOCK 1H, LOTS 2~A ~ 24A A.J.G. ~ """-g'"-~'~/ ~PE OF WORK: DESIGN DRAWING OF PROPOSED SEPTIC SYSTEM 8/19/2010 (Rev. 01/05) IPROFILE VIEW OF1 PROPOSED BED I1"=10'I SLOPE) GROUNDWATER @ , RABBIT CREEK HEIGHTS S/D; BLOCK 1H, LOTS 25A & 24A A.J.G. PROFILE DRAWING OF PROPOSED SEPTIC SYSTEM 8/19/2010 (Rev. 01/05) LL~ RABBIT CREEK HEIG , ,, ~ I fl" I I BLOCK 2H, LOT 17 \/ ~ I u)', I \\\/ ~ I /, I BLOCK 2H, LO~ 16 ~ ~ I ~, I / ........................~ --~__ ~ X k .......... ~<-----¢- n _~, ...... y~---~ .... ~~ SHED~ ~ ~ I ~ ~ ~ ~' o ~ ~ ~ u o ~ SEPTIC 0 ,, ,, . ~_~_ ~ - ~ / - _~__/ -~ -~ARINO DRIVEk~ //~'~ ~ .~ ~aa~} CAKE, HE~S ~ / ~ ~ ak~,.~H, ~o, ~. ~o, ~ s,~ ,o~ · ~c.o~ ~ o~. ~,o,~ (~o~m~-~ · ~ (~on~-~ · w~s~ .~.~ .... ¢.,~,g.=~ ~ /.,", ,~ MARY ELDRED 545-1S01 4 Or 5 ~'¢~.¢ -~¢fr~y &~rnes~.. RABBIT CREEK HEIGHTS, BLOCK 1H, LOT 25A A.J.G. ~ GARNESS ENGINEE'RING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. 'TUDOR ROAD, SUITE 101 * ANCHORNSE, AK. 99507 * PHONE: (907)337-6179 * FAX: (907)338-3246 * WEBSIIE: gomessenglneertng.com ISOIl LOG - PERCOLATION TESTI LEGAL DESCRIPTION: RABBIT CREEK HEIGHTS S/D; BLOCK 1H, LOT 25A & 24A PERFORMED FOR: MARY ELDRED DATE: ORGANICS TEST HOLE #ql SOIL CLASSIFICATIONS ML CLAY GW ~ ORG GP GM CL GC OL SW HH SP CH SM OH SC DEPTH TO GROUNDWATER DATE DRY 8/16/2010 4' 8/17/2010 DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 8/17/2010 1 3:20 - 6- _ 2 3:50 30 5 3/4" 1/4" 3 3:50 - 6- _ 4 4:20 30 5 3/4" 1/4" 5 4:20 - 6,, _ 6 4:50 30 5 3/4" 1/4" PERCOLATION RATE 120 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) SOILS LOGGED BY: COMMENTS:. TEST RUN BETWEEN 0.5 FT. AND 1.5 FT. A FOUR HOUR PRESOAK WAS PERFORMED: · YES ROB CAMPBELL PERCOLATION TEST PERFORMED BY: [] NO ANDREW GRAY PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS )°ERFJ;)RMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: _~/Z_~/? m S 89°28'49"W !05.!7' S 89°28'49"W 105.03' ! 10' UTILITY EASEMENT [ 10' UTILITY EASEMENT, '--'~J~'~'~-~' Based upon an asbuilt ~ 5r5' survey by Shane Holt .....J / LS-6914, dated 8/23/07 ~~ ~ o . Existing 1250 gal Holding Tank Test H ~3 ~ / °well LOT LOT 24A ~ 8~°3~%4"~ ~04.~2~ ~ 8~°3~'44"E 74.~5' ~, Merino Drive Rabbit Creek Heigh~ BIk ~H Lots 23A & 24A Site Plan for Septic Upgrade . ~:&~.-" Ma~. Eldred Watkins Enqineering,~ inc. Parcel ID: 020-55~-02 Cindy W.' Ellis, P.E. P.O. Box ZZ0443 ';~ . CCDY W. E~US August 31, 2007 Anchorage, Alaska 99511-0443 Scale 1 inch = 30 ff Phone: (907)349-1851, Fax: (907) 349-1934 Performed For: Legal Description: 5- 6- 7- 8- 9- 11- 15- 20- Depth ',Feet', ML BOH Municipality of Anchorage Development Services Depa~ment Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. BOX 196650 Anchorage, AK 99519-6650 www.munLor§/onsite (907) 343-7904 Soils Log - Percolation Test Mary Eldred Rabbit Creek Heights, Block 1H, Lot 23A Test Hole #1 Fill 1.25 Organics 2.5 brown silt 4.5 blue clay 8.6 Slope  <1 ~% Date Performed: 7-17-07 Township, Range, Section: Site Plan Se e l~tt~tch,.~d SJ te Plain I I I I WAS GROUND WATER ENCOUNTERED? YES s IF YES, AT WHAT DEPTH? 3.25 L O Depth to Water After p Monitoring? 5.12 E w/curtain Date: 5-15-08 drain Reading Date Gross Time Net Time Depth to Water Net Drop 1 7-20-07 2:54 0 6 -- 2 3-4 5-6 3:24 3:24-3:54 3:54-4:24 30 30 30 6-4.25 6 -4.25 6 - 4.25 1.75 1.75 1.75 PERCOLATION RATE 17 (minutes/inch) TEST RUN BETWEEN 3.0 FT AND 3,5 COMMENTS 7 Hr Presoak prior to test. Curtain drain installed upgradient from TH and groundwater was monitored. PERC HOLE DIAMETER FT PERFORMED BY: Rocky Trainor/Cindy Ellis I Cindy Ellis P.E. CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN ¢¢FECT ON THIS DATE. DATE: 8-18-09 Performed For: Legal Description: Municipality of Anchorage Development Services Depsrtment Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ,Soils Lo0 - Percolation Test Mary Eldred 5- 6- 7- 8- 9- 10- 11- 12- 13- 15- 16- 17- 18- !9- 20- Rabbit Creek Heights, Block 1H, Lot 23A Slope Test Hole #2 i Organics l 2.0 ML Ibrownimpereable' 4.0 ML blue6.5 clay ~OH :10!~ I I I WAS GROUNDWATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water After Monitoring? ~" -.z,~,.. Date ~efformed: 7-~7-07 Township, ~an~o, Section: Site S~e ~tt;~ch_=d SJ.te Pl,~n I I I I I I I Reading Date: no PERCOLATION RATE TEST RUN BETWEEN COMMENTS No perc test conducted. Soil appears impermeable. Date Gross Time Net Time Depth to Water PERFORMED BY: Cindy Ellis I PERFORMED tN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. Net Drop (minutes/inch) PERC HOLE DIAMETER FT AND FT Cindy Ellis, P.E. CERTIFY THAT THIS TEST WAS DATE: 8-18-09 Performed For: Legal Descri'ption: Depth (Feet] 1- 2-~ 3- 4- 5- BOH 6- 7- 8- 10- 11- 12- 13- 14- 17- 18- 20- Municipality of Anchorage .Development Services DepaEment Building Safety Division On-Site VVater and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Soils Log - Percolation Test Mary Eldred Rabbit Creek Heights, Block 1H, Lot 23A Test Hole #3 Fill 1.3 __Organics 2.0 blue clay Date Performed: 7-17-07 5.0 Township, Range, Section: Slope I I i° ~\ I I I I Site Plan S( e ,tt tch ~d S: te P1 tn WAS GROUNDWATER ENCOUNTERED? no S IF YES, AT WHAT DEPTH? L O Depth to Water After p Monitoring? E Date: <]0% Reading Date Gross Time Net Time Depth to Water Net Drop .1 PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT COMMENTS No perc test conducted. Soil appears impermeable. t /'~.;',;-/ tf/:,-,/ f -* /., PERFORMED BY: Cindy Ellis I Oindy Ellis, P.E. /~ERTIFY THAT THIS TEST WA8 PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNIOIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 8-18-09 Undeveloped i / ..................... ' ~ ~5A . / 14A 13A 27A 26A 25A 24A , ,', TH~I '¢3~ ~ . ~ _?iveway [~ Undeveloped -:';: · ~ ~ ~ic Area ~ ~~// / ~ Septic Area ~~ o / ~ ¢ ¢: ~ o> ,.dew,o,ed ,.deve,o,ed ~ . WELL / ~ BLOOK 4H WELL < ~ ~ BLOOK ~H 38A 2A 3A ~ ~ ~ ~ ~- ~ ~ ~ 6A 39A 9~ 40A / / ~,~ Heigh~ Blk 1H Lo~ ~3~ & 24A Site Plan for Septic Upgrade Watkins Engineering, Inc. Cindy W. Ellis, P.E. P.O. Box ~Z0443 August 31, 2007 Anchorage, AK 99511-0443 Scale: 1" = 100' Phone: (907) 349-1851 Fax: (907) 349-1'934 '~.,.%. , 7 ~r- T m C 03 '-q rtl r-- Cig 0 X < ZO rq -40 Z ITl --t Cr-- Z~--. ---I Z 0 C 0 -4 CZ 13[] m IDRAWN BY: DATE:8/2$/2010 IJ.L.M. LEGAL DESCRIPTION: RABBIT CREEK HEIGHTS; BLOCK 1H, LOT 25A & 24a TYPE OF WORK: DESIGN OF QUANICS AEROCELL SYSTEM CONSULTANTS&GENIEP~LCO~ITI~ACrOt~S ~-- TUDOR ROLO, sung 101. ANCHORAGE, AK. 99507 PHONE= (go7) 337-6179/FAX: (gO7) 338 5246 PREPARED FOR: MARY ELDRED IPHONE NUMBER: 907-441 -8499 JPA,~E: OF 5 ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this ~__~t.~ Dayof ]r~'/Sxtz%~,3 , o~ 2010, by and between /~[o-~.~ ~ jC./(/'e'C/~/ herein the "OWNER." and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATERTREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as &_._LA-~. ~/C.£ /~ ¢ '~c'~ e $~located at_~c~}o[o,~r (re~/q l-}[s. /5t/4 d--3 ' ,Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an AWWTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipalit5 pursuant to ,Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On-Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals ceftin, that the systems are adequate for the homes that the3" support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The s~heduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On-Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On-Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of ($ ~) .00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversaO' date of the approx al by the Municipalit? of installcd system. 4. Term. The term of this Memorandum of Understanding shall be for the life of'the AWWTS. ]"he term begins on the date of approval by the Municipality of the installed sx stem and shall continue w'hile the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On-Site approval is issued to the new owner or transferee of the property. 5. Alterations~ Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality,. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibilits' of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations. rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: _2~,,( c .i'5'I ~o0/' C. Owner acknox~ledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. Owner: ______~//~ . _ Anchorage: Purchasing Officer C, An3' attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: Title: Date: '~.~{ C? Date: STATE OF ALASKA ) ) SS. THIRD JUDICIAL DISTRICT ) MUNICIPALITY: The foregoing instrument was.s~cknowledge,d before me thisCX/VdaY of 2OLd, by /%7 ~ ~/ dt~ . NOTARY PUBLIC FOR ALASKA My Commission expires: Z~','~Z. ~ ~-~:/(