HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 3H LT 16ARabbit Cr k View & H ight lock 3H Lot 16A 020- 561 -17 sen~ b~ : 3441976 SPINELL HOMES 04-26-11 04:09p Pg: 1/2 April 26, 2011 .'.:57 349-3 231 Anchorage Attention: Spinell Homes This letter is to confirm that the lift station at 15AJ16A Rabbit Creek Heights was wired in accordance with the 2008 National Electrical Code by a licensed Residential wiremam If you have any further questions please feel free to call our office at 349-3231. Thank you: Fuchs Electric Inc. Gary L Momosor Contractor Fax sen~ b9 : 34419?6 SPIHELL HOMES 04-26-11 04:10p Alpine Drilling & Ent rises Well Log Permit Number: #SWOSP101189 Date of Issue: 9-20-10 Parcel Identification Number: 020561170000 Date Started: ~ 1-23-10 Date Completed: 14-25-10 Is well located at approved p~rmit location? x Ye~ [] No Legal Description: Rabbit Creek View & Heights Bloc 3H Lot 16A G: 3340 Property Owner Name & Address: Benson Gunnar PO Box 232032 Anchorage, Alaska 99523 Borehole Data: Soil Type, Thickness & Water Strata Stick up organics silt gravelly silt silty gravelly sand & H20 silt silt w/ sand gravel lenses/1t20 silty gravel 1120 Bedrock Depth (ft) From To 0 d II 71 71 77 77 88 88 137 137 143 143 208 Method of Drilling x air rotary [] cable tool Casing type: steel Wall Thickness: .250 inches Diameter: _6 inches Depth: 14~6 feet Liner Type: ~ Diameter: ~ inches 'Depth: __ feet Casing st!~kup above ground: ~..feet Static water level (from ground level): O__feet Pu~ping level:. 208 feet after , o~. hours pumping_5 gpm Recovery Rate: _5 gpm Method of Testln_~: air till Well Intake ~Opening Type: [] Open End x Open Hole [] Screened Start feet Stopped~ [-] Perforations Start feet Stopped Grout Type: B.e. nt~ni~ aemen, t grout Depth: Start 0 feet feet feet Volume: 60 gal Stopped 20...2.+ feet Pump: Intake Depth ~ feet Pump size __ hp Brand Name __ Well Disinfected Upon Completion? x Yes I'[ No Method of Disinfection: Chlorine tab[¢t~ Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 Mark Begich Mayor Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 1966§0 Anchorage, AK 99§19-66§0 www.muni.orq/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SWOSPIOl189 Date of Issue: 9/20/10 Parcel Identification Number: 020-561-17 Replacement Only: YES NO Legal Description Lot 16A, Block 3H, Rabbit Creek Heights Property Owner Name & Address: Spinell Homes Pump Installation Date: 4/21/2011 Pump Intake Depth Below Top of Well Casing: 193' feet Pump Manufacturer's Name: Goulds Pump Model: IOSB07 Pump Size 3/4 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: Spinell Well Disinfected Upon Completion? [] Yes [] No Method of Disinfection: Recirc Comments: Pump Installer Name: Aarow Pump & kVell Service LLC PO Box l10496,Anchorage, AK. 99511 (907) 346- 9355 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: May 16,2011 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 16A, Block 3H, Rabbit Creek Heights Subdivision Certificate of On Site System Approval (COSA) The following modifications have been made in accordance with your review comments for the conditional COSA for the subject property: 1. The curtain drain was not installed. No groundwater or runoff water was encountered during October of last year. A drainage swale was completed along the eastern property line prior to the construction of the absorption bed. This swale may be effective in controlling the surface water which may affect the new bed. We intend to monitor the area during breakup of this year. It surface water becomes a problem, the drain will be installed. The final approval for the COSA will not be requested until after breakup. At that time we will know whether the curtain drain is necessary. 2. The percolation test was required because the alternate site was not totally within the 30' radius of a percolation test. The final as built shows both the primary and alternate sites within the 30' radii of the percolation tests. No further testing is therefore necessary. All percolation tests completed during construction however indicate the soil is consistent throughout the absorption area. 3. The buyer, Mr. Gunnar Benson, completed the Maintenance Agreement during the permitting phase of the project. 4. The waiver to surface water request has been modified to show the current status the absorption bed. It is attached to this memo. Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 ,,ht,,,tp:llwww.muni.or,qlOnsite Development Services Department On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** Waiverg: SP101190 REVISED COSA#:~ Permit#: OSP101189. PID#: 020-561-17 Legal Description: Rabbit Creek Heiqhts Block 3H Lot 16A Engineer: Anderson En.qineerinq Applicant: Benson Gunner Your request for a waiver of the required 100 feet horizontal separation from the absorption field to the surface water has been approved. The approved separation distance is 54.0 feet. This waiver approval applies to the existing absorption field to surface water separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: · ' Nam~ of Revi - er Rec#: 014407 Amount: $800.00 Date Paid: 9/7/10 **** VARIANCE/WAIVER REVIEW **** ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) May 16, 2011 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 16A, Block 3H, Rabbit Creek Heights Subdivision Septic Tank and Absorption Bed to Surface Water Waiver Dear Onsite Services Engineer: Very little surface area is available for construction of a septic system on Lot 16A, Block 3H, Rabbit Creek Heights Subdivision. The new absorption bed was constructed in the southeast corner of the lot which is located directly north of a flowing ditch on the south side of Diane Drive. The southwest corner of the new absorption bed site is 54' from the ditch. A waiver is therefore necessary from the 100' setback required by ordinance. An Advantex Treatment System was recently constructed on the lot which provides additional treatment to the septic effluent. In addition, the surface drainage path is away from the ditch at a 7% grade. If the system should ever overflow the effluent would follow the natural drainage path away from the ditch. The elevation of the ditch is currently higher than the existing ground in the area of the new absorption bed. The soils underlying the absorption bed are very good to excellent. The likelihood of a failed septic system and overflowing effluent are very Iow. Should the situation occur the flow is to the northwest away from the surface water. We therefore recommend the waiver be issued allowing the septic system to remain in its constructed location at 54' from the surface drainage. Sincerely, Michael E. Anderson, P.E. Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP101189 02056117000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: September 20, 2010 to September 20, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: RABBIT CREEK VIEW & HEIGHTS Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 3H LT 16A G:3340 Owner/Address: BENSON GUNNAR PO BOX 232032 ANCHORAGE AK 995230000 Site Mailing Address: 16401 DIANE DR, Anchorage Lot Size in Sq Ft: 21661 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. AMC 15.65.060.B3 Received Issued By: Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www. muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION t,/,~"'"'"~" 0~1~11 qO FORA SINGLE FAMILY DWELLING Parcel I.D. 020-561-17 Property owner(s) Spinell Homes, Inc. Mailing address 1900 w. Northern Lights Blvd. Suite 200 Anchorage, AK Site address 16401 Diane Drive Anchorage, AK Day phone 344-5678 Zip Code 99518 Zip Code 99516 Legal description (Sub'd., Block & Lot) Lot 16A, Block 3H, Rabbit Creek Heights Subdivision Legal description (Township, Range & Section) Lot Size 21,661 Sq. Ft. Number of Bedrooms Three (3) THIS APPLICATION IS FOR ([~ all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and i~ in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ~",~,~) ~ Z¢~ Waiver Fees: Date of Payment: Ot/~/](~ Date of Payment: Receipt Number: O / L~ L~ (f,) 7 Receipt Number: (Rev. 11/05) September 4, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 16A, Block 3H, Rabbit Creek Heights Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 16A, Block 3H, Rabbit Creek Heights Subdivision intends to construct a three-bedroom home on the lot. We are therefore requesting a permit be issued for a well and septic system to serve the new home. The available area for the septic system is limited by the presence of ground water close to the surface which make it difficult to place a conventional septic system. We therefore propose to place an Advantex Treatment System on the lot to provide the most effective treatment of the septic effluent prior to discharge into the surrounding soil strata. The location of the absorption system is shown on the attached Site Plan. A subdrain will also be placed to control surface and subsurface drainage in the area of the new absorption bed. Drainage patterns are also shown on the plan and will be modified somewhat as a result of the proposed construction. The ditch on the south side of Diane Drive flows nearly year round. A waiver request is attached to decrease the separation distance from the ditch to the absorption bed to 72'. Two test holes were placed on the lot by Watkins Engineering in November of 2004. A third test hole was recently placed in the area of the Watkins Test Hole No. 2. Ground water was found at a depth of 4' below the surface. The percolation rate in the materials encountered was 9 minutes per inch as opposed to 4 minutes per inch on the Watkins test. Our design provides for the bottom of the absorption bed to be at 2.5' above the ground surface. We are therefore proposing to place a three-bedroom Advantex Treatment System. The absorption bed will be 10' long x 15' wide for a total of 150 square feet of absorption area. The distribution line in the trench will be placed at 3.5' above the existing ground level. 2' of fill and 2" of insulation will be placed above the bed and 4' over the septic tank to meet Municipal Code and prevent freezing. The side slopes of the mound will be at 4:1 and extensive landscaping and fill will be reqUired to insure positive drainage away from the finished mound. Lot 16A, Block 3H, Rabbit Creek Heights Subdivision September 4, 2010 Page Two The ground surface of the lot slopes from the southeast to the northwest at a 7% slope. The bed will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from the well proposed for this lot. No conflicts exist between the proposed well and septic system and those in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: September 16, 2010 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 16A, Block 3H, Rabbit Creek Heights Subdivision Well and Septic System Construction Permit No. OSP101189 We reviewed your comments and offer the following response: 1. We measured the water levels in the monitor tubes yesterday, September 15, 2010, and found the water level in our Test Hole No. 3 at nearly 7'. Cindy Ellis' Test Hole No. 2 was at 4'. We found more than 2' of native unsaturated soil and invite your inspection to verify the levels. The previous summer has been much wetter than past years and the water table is probably higher now than typically found at this time of year. In addition, a ditch was installed in the recent past along the east property line which may be assisting in lowering the water table. The ditch is currently dry, but redirects surface runoff to the north and away from the test hole area. We have revised our Site Plan to utilize the ditch for the new subdrain planned for the lot. We therefore request that our measurements be used for the evaluation of the septic system design and issuance of the permit. 2. The calculations have been corrected on the soils log. The percolation rate changes by slightly more than a minute and is actually less conservative than the rate shown. 3. We are unsure of Cindy Ellis' water monitoring and prefer to rely on our data. As previously mentioned the past summer has been much wetter than the summer the test holes were placed. The water table today should therefore be higher than the year Cindy Ellis performed her monitoring. 4. The maintenance agreement will be forwarded directly by Spinell Homes. 5. We have modified the Site Plan somewhat based on our last field inspection. The modification resulted in moving the proposed absorption bed closer to the open ditch to the south. The request for modification to surface water has been change to 60'. ',\, 15 15 GEORGE COURT 26 27 20 AREA MAP SCALE 1' -- 100' RABBIT CREEK VIEW & LOTS PLAT NO. 2004-91 RABBIT CREEK HEIGHTS 15A & 16A, BLOCK 3H SUBDIVISION REPLAT LOT 15A 19,751 S.F, Under Driveway NOTE: Reconstruct Ellis TH2 to Match Characteristics of Existing Ground Prior to Construction of Absorption Bed. ~0o o / \ \ \ \ \ \ \ \ Proposed Well LOT 16A 19,751 S.F. \ / Outfall Subdroin 'hree Bedroom Advantex Treatment System with with AX20 Pod and Add On Lift Station. 10' Wide x 15' Long Absorption Bed, LEGEND MT - Monitor Tube FCO- Foundation Clean Out TH - Test Hole CO - Clean Out MH - Man Hole LS - Uff Station LOT 16A, BLOCK 3H, RABBIT CREEK HEIGHTS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Raised Bed System Perc. Rate: 4-9 Min./Inch Advantex Treatment System for 3 Bedroom Home Application Rate: 4 GPD/SF 500 Gallon Lift Station 2.5' (Min.) Coarse Sand 3 Bedrooms X 150 GPD/4 GPD/SF (Application Rate) = 112.5 SF Absorption Area 112.5 SF/15 SF (Width) = 7.5 LF Bed Length THEREFORE: Construct a 10' Long x 15' Wide Raised Absorption Bed as Shown Below. Remove Existing Organic Material and Replace with Coarse Sand. Level Bed Area with Coarse Sand. Place Distribution Piping at 3' Above Original Ground Surface. Provide 2" of Insulation and 2' of Cover Over Bed or 3' of Cover. Place Topsoil and Seed on Outer 6" of Mound. Replace With Clean Sand (See Specification) 1.5' Level Bed as Necessary With Clean Sand Min. NOTE: 2.5' 5' 5' 2.5' I I I I I See Specifications for Clean Coarse Sand. TYPICAL RAISED BED SECTION (NO SCALE) -\~. ....... ~ ..o%E ........ ".'~,. NOTE: Grade Area Surrounding Bed to Drain Away. ~/ 49th ~ ~ Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. ~~:'~~ Minimum 100' Separation From Wells in the Area. ~;~t;'"~i;~;;¢'~'.%~;~';~'7~ Minimum 100' Separation From Su~ace Water or Streams. _ ~.'¢.~ No. CE-4381 Minimum 10' Separation From Water Se~ice Line. ~'~,,:-~%...~_~v,~ ~...'~'~-~-- LOTS 15A & 16A, BLOCK 3H, RABBIT CREEK HEIGHTS SUBDIVISION ~xisting Ground Geotextile Fabric Drain __ Rock Perforated PVC Delta Drain TYPICAL SECTION SUBDRAIN NO SCALE 8- 9- 11- 12- 13- 15- 16- 17- 20- COMMENTS Performed For. Legal Description: ~M - Municipality of Anchorage Development Services Department Building Safeb. y Divisicn On-Site Water and Wastewater Program 4700 Elmore Road P.O. Bc0~ 196650 Anchorage, AK 99507 www. ci.ancharage~ak, us (907) 343-7904 Soils Log -PercOlation Test Spinell Homes / Rabbit Creek Heights Subd., Lot 16A, BIk 3H Slope i WAS GROUND WATER ENCOUNTERED? Yes S IF YES, AT WHAT DEpTH? -6.6' L 0 Depth to Water Aftra- p Monitoring? -4.0' E Dale: 8/30/2010 Reading Date Gross Time r Net'Time Depth to WaterNet Drop ~/~2o~o i;~:~u /~ -7. s ,~ ,' ~ I~ :0(o 5~, ~,&, II. ~ ?~'' ~. ~-" PERCOLATION RATE "~."~ ,.ej- (minutes/inch) TEST RUN BETWEEN -2.0 FT AND PERC CAVITY WAS PRE-SOAKED PERC HOLE DIAMP-.~EI~ -2.5 FT pROPERTiES, 6- 7- 10- 13- 14- 15- 16- 17- 18- 19'- 2O- COMME~[S Soils Log - Percolation Test Patti Helm 13,5 O~ ~: 11/30t04 Towmalp, ~nge, Section: Sae Pi~n s:4S 10 , ,, 3.0 3.0 10;02 1(3 3.125 2.875 10:14 10 3.562 2.438 10;26 10 3,562 2.438 10:37 10 3.625 2.375 10:49 lO 3.625 ?_375 PERCOLATX:)N RAI~ 4 m~-'~ lar~c ~)LE DiAne ~e~< e TE$1'RUNaEIWEEI~ 15 Iq' ANO 2.0 Fl' 9'd gg~-i717g-Z06 laSUeH esaJal eLL:LL [")L qo /,elAI ~ Desa'iptJ~: 13- 14- 15- 16.~, 17- 18- 19- Soils Log - Percolation Test Patti Helm ~=L A'T I 1Z'1t~ 10~0 0 6 - 2 mo:~ 30 5,~S 0-375 ..... -3 . ~0:31 0 6 - 4 1t:01 ~ 5.6~ 0.375 ~ ./'d ~gS'S-tz~-Z06 }@SUeH eseJel eLL:LL f3L qf~ AelAI MUNICIPALITY OF ANCHORAGE 0 fdl Development Services Department s Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 020-561-17 1. GENERAL INFORMATION Expiration Date: Complete legal description RABBIT CREEK VIEW & HEIGHTS BLOCK 3H LOT 16A Location (site address) 16401 DIANE DRIVE, ANCHORAGE, AK 99516 2, - 3---2 ( 2Z Current property owner(s) KURT NAGEL & LASHAWN DEIBERT-NAGEL Day phone Mailing address Real estate agent PO BOX 111215, ANCHORAGE, AK 99511 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment Date of Payment Receipt Number Receipt Number COSA # Waiver # STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 11/29/2021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & FkS 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Q',r� rI l �ZiL Curtis Huffman% CE 128991 / >>, �PROFESSOkV Conditional approval for bedrooms, with the following ``i,R tl WATERAND Original Certificate Date: f Zr 3 ^ 21 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist Legal Description: RABBIT CREEK VIEW & HEIGHTS BLOCK 3H, LOT 16A Parcel ID: 020-561-17 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ® Well log is filed with Onsite (or attached) Date drilled 11/25/2010 Total depth 208 ft Cased to 146 ft ® Sanitary seal is functioning correctly ® Wires are properly protected Casing height (above ground) 24+ in. Date of flow test for COSA 4/28/2011 Static water level at beginning of test ARTESIAN PLUG ft. Comments B. TANK DATA Age of tank(s) 11 years Tank type/material SEPTIC - ADVANTEX / STEEL Measured operating fluid level in septic tank * ® Standpipes/foundation cleanout per record drawing Date of pumping 7/2/2020 D. ABSORPTION FIELD DATA Which system tested (date installed) 12/2/2010 ® ALL standpipes present per record drawing Total measured depth from grade 6 ft (max) Measured depth to pipe invert from grade _ft (min) ® N/A — pressurized field ® Monitor tubes go to bottom of effective. If not, state depth into effective Well production at time of test 4.1 gpm _ . Water storage tank volume NA _gallons_. Well disinfected for coliform test? ❑ Yes ® Nc ® Coliform bacteria is Negative Nitrate 0.472 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ® Arsenic less than MRL (ND) Collected by FS Date of Sample 4/28/2021 & 11/12/21 C. LIFT STATION ® Required maintenance completed Age of lift station 11 years Lift station material PLASTIC — PUMP VAULT Comments: *ADVANTEX — SEE MAINT. Adequacy test date 4/28/2021 Results 2 Pass For 4bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 4_5 in Elapsed time 1185 min ®Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate 600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) If yes, enter date Gallons introduced gallons MIS NO SURFACE WATER OBSERVED IN DITCH ALONG ROAD AT TIME OF TEST. E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) ® Yes Septic Tank/Lift Station on Lot > 100' ft Surface Water > 100' ® Yes if No ft Community Sewer Manhole/Cleanout > 100' ® Yes if No ft ® Yes if No ft Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No ft Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No ft _N.eighb.oring_Absorption_Fields> 1-00' _ — _ __ _ ___ _Animal- Containment >_-50' ® Yes—if-No-ft ® Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ®Yes if No ft ® Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No ft Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No ft Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes . if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ❑ Yes if No *54+ ft F. ENGINEER'S COMMENTS *WAIVER #OSP101190 & NEW CODE ALLOWS 50'+ TO SURFACE WATER WITH CAT III SYSTEM. G. ENGINEER'S CERTIFICATION I certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Adw TH ...... ....v..`.. • Curtis Huffman CE 128991 ROFESSIONO'�— � 07/0612021 07:16 8686770 APLUS PAGE 08 394 814 I� ❑i0 ■o R son R wool on r Boom s o l■■ ■ ■■ ■ ■ ■ ■ i ■ on ■ ■i ■ ■ = 8 o on mons■■ n■ ORLON AnR i-0 Arra nTe,,j e Field Maintenance Report Anchors eTank Annual Ins uction P an7-97*D_qr.d1 Property 4vmerhrWXlD0 K op9nttOr - — Kurt Nage! Larry Betts 2nd Compartrnent Me Addraas Previous Contact Phono 16401 Diane Drive Anchorage AK 99516 (907) 555-5555 AX SR9 I0 N County ID k Pod 4RTU 8NL k Dote of Lint inapectlon AX -125966 0$P101188 1411684 RZ122351 07/07/2020 Retrieve O&M Info Daily flow_,, - Recim ratio Timor somings: Perform Field SamP1 Ing/Observations NTU (15 t NTUa) p ! (6-9) D4 (2.6) -I 4� Previous 2nd Compartrnent meat Ampre C5,0-.- Must - ❑ Earthy ❑ Moldy Nan-typlcl ❑ Sulflt iB ❑ Cabbage ❑ DOCay Oily film in PVu [ f Yes ❑ No Foam In tank ,dyes No Check Control Panel Recirc Amps Discharge Amps /,?,; Audible and visual alai nsOK Dial tone (tolometry an .f) A yes/N a inspect/Clean Pump system " " Insp Clean Rlsor/Lid ......... Splice Box .... . . . . ..........�( Float Cents .. . . . . . . .... . .....11�" Floats ........................ J`—' 0 Pump ................. ...::R.T SiotubVb Filter ...... . ...... . 6lotube Pump vault - , /�i Recirculating Splitter V i Iva_ .. _ , .. Imo+ Comments Signature�:' Measure Sludge/Scum Sludge Seam Int Compartment Current Previous Current Previous 2nd Compartrnent Current Previous CurrentT-IL"Ous Inspect/Clean AdvanTex Filter Inspect Clean Odor zNormal ❑ Pungent Laterals/Orifices z Biomat: / Normal ❑ SXCOSSIVa Pod Bottom ---/// Bridging/Pondl n/ Nonc/Minor ❑ Excessive Intake vent Inspect/Clean Discharge pump System r— Inap t Inspect Clean Risor/Lid Floats fJ Splice Sox Pump f r Float coals A / — Inspect/Service Other System Components Ins�po{ t Clean Inspect Clean Disinfection Equipment , I j✓1 Dispersal Lat,.rals/OriTrces — Observations �- Additional Services Rendered ❑ Cleanest textilo sheeta? ❑ Replaced UV items? ❑ RaplaOLWUsed othor items? Paris Used: W - Warranty, R a Bllable W appropriate Selection) w B item Number Descrilrtion Fiinal Safety Inspection R$V reinstalled Manifold reconnected; fluah valves closed Sum ma ry/Recommendations System performing; no further action needed � ASV Data Fax competed form to 1-866-384-7 Lids bolted on Control panel reac#Ivatod [Tank noods pumping ❑ Other? ZV ,5E, { 17iII11CIPALITY OF ANCHORAGE THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of of 20 , by and between Lyndsay & Travis Hammond , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description) AN ADVANTEX SYSTEM RABBIT CREEK VIEW & HEIGHTS BLOCK 3H LOT 16A 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) 4-1k Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. ``t` `� It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This 1 includes an annual maintenance fee (typically $400 to $600). 14�V Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. AAZ Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. L Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14:00,030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. �j Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. �. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 Q GYNE+ R- BY e) Date: 2 STATE OF ALASKA, ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before m s ? y of � 20..(, byTraviS J tkm� dC�j_, 0,1111. NOTARY PUBIAC FOR ALASKA My Commission expires:y5— 3 -� MUNICIPALITY: BY (signature) ����.a`'� STA "+`'�%'�. Al�p 14 PUBoo kTf ti %, �� •.;4� OF Pte' a� •' EA Date: S �2-0 —7 (print name) Title: (rev. 05/18/2018) Page 3 of 3 tic UU1 GULU 1J. U'+ UWQW r r U HI I—U../ I f—iUL 1U R srmmm Ems [AilvanTei '0 Field Maintenance Annual lnsp� Mian Properly Ovtner/Trackinp 8 Kurt Nagel Site Addroaa 16401 Diane Drive, Anchorage AK 99516 AX Site ID H County ID 6AX-125966 County Retrieve O&M Info D311y flow REcirc ratio Timer settings: Perform Field SamFd ng/Observations NTU (IS !t NTU-n) pi (6-9) DQ (2-6) 0/ Odor of Sample Typical must ❑ Earthy 0 Moldy Nontypical M, ulflc t ❑ Cabbage ❑ Decay Oily film In PVU [ Yes N No Foam in tank [_ Yes to Check Control Panel Recilr. Amps Disaharga Amps �3 Audible and visual aim nsQ)< Dial tone (tcMmctry on r) ❑ Yes KNo Inspect/Clean {pump 3yStein Inspect Clean Riser/Ud .......... ......... Splice Box ......... ...... . .. Float Corda ........ .......... Floats............. ....... . . Pump....................... Blatube" Filter . . . . . . .......... Biotube Pump Vault ............ Recirculating Splittar L Iva..... Comments _ �`—• Signature!_ Pod N 411684 366 578 till III BEEa 8an9 ISM AnchorageTank 907-272-3543 Opemtor Larry Betts Contact Phone (907) 5555556 RTU WUL N Date or Leet InmecUon RTU122851 05/18/2419 Measure Sludge/Scum Sludge Scum 1 at Compartment Currenz t` Previous, Current Previous 2nd Compartment Currant Previous Current Previous Inspect/Clean AdvanTex Filter Odor. j4 Normal ❑ Pungent 8iomat: Normal F� Excessive Bridging/Ponding: one/Minor ❑ exocs"two Inspect/Glean Discharge Pump System Inspect Riser/Lid Splice Box Float cords Inspect/Service Other System Components Inspect Clean Disinfection Equipment Dia Obsorvatlons Inspect Clean pemai LateralsfQrlAccs Additional Services Rendered ❑ Cleaned textlio sbcFts? ❑ Replaced UY items? ❑ Replaced/Us,)d other items? Parts Used: W = warranty, B � Billable t✓ appropriate selection) W B Item Number Description Final/Safety Inspection SV reinstalled nlfold reconnected; flush valves closed Summary/Recommendations System performing; no further action needed ❑ Call for secvlce Date Pax completed form to 1-866-384-7404 Lids bolted on Control panel reactivated ❑ Tank maids pumping ❑ Other? Inspect Clean Laterals/Orlfices ❑ Pod Bottom Intake Vont ❑ [nape Clean Floats Pump Inspect Clean pemai LateralsfQrlAccs Additional Services Rendered ❑ Cleaned textlio sbcFts? ❑ Replaced UY items? ❑ Replaced/Us,)d other items? Parts Used: W = warranty, B � Billable t✓ appropriate selection) W B Item Number Description Final/Safety Inspection SV reinstalled nlfold reconnected; flush valves closed Summary/Recommendations System performing; no further action needed ❑ Call for secvlce Date Pax completed form to 1-866-384-7404 Lids bolted on Control panel reactivated ❑ Tank maids pumping ❑ Other? Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-561-17 GENERAL INFORMATION Complete legal description Location (site address) COSA# 0~'~(~_\ \ Expiration Date: --// Lot 16A, Block 3H, Rabbit Creek View and Rabbit Creek Heights Subdivision Replat 16401 Diane Ddve Anchorage, AK 99516 Current Property owner(s) Spinell Homes, Inc. Day phone 343-1600 Mailing address 1900 W. Northern Lights Boulevard Suite 200 Anchorage, AK 99518 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: Three (3) TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class ~ Well [] Public Water System [] TYPE oF WASTEWATER DISPOSAL: Individual On-site [] IndividUal Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B Wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedf7 that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE Approved for Disapproved. ~'4~' Conditional approval for bedrooms. Phone 522-7773 Date 5/5/2011 bedrooms, with the following stipulations: - By: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory - Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: (Rev. 11/05) Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA Well type Pdvate Date completed 11/25/~0 Total depth 208 ft. Lot 16A, Block 3H, Rabbit Creek View and Heights Sub. Replat IfA, B, or C provide PWSID # Sanitary seal (Y/N) Y Date of test Static water level 0 Well production 5 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Arsenic: N/D mg/I B. SEPTIC/HOLDING TANK DATA Tank Type/Material Advantex/Fiberglass Tank size 1,500 gal. Foundation clean0ut (Y/N) Y Date of pumping New Const. C. ABSORPTION FIELD DATA Date installed 12/1-2/10 Parcel ID: 020-561-17 Cased to FROM VVELL LOG 11/25/10 146 ft. g.p.m. Nitrate .464 mg/L Date of sample: 4/26/11 Well Log (Y/N) Y Wires properly protected (Y/N) Casing height (above ground) __ AT INSPECTION g~p.m. Number of Compartments ~Two Depression over tank (Y/N) Pumper Soil rating (g.p.d./ft2 or ft2/bdrm) 4 GPD/SF Y >18 in. Length 25 ft. Width ~5 ft.. Total depth + 6.4 ft. Eft. absorption area 375 ft2 Monitoring tube Date of adequacy test New Const. Results (Pass/Fail) Fluid depth in absorption field before test in. Water added Elapsed Time: ~ min. Final fluid depth in. Any rejuvenation, treatment (past 12 mo.) (Y/N & type) Other bacteria N/^ colonies/100 mL Collected by: A. Harala ' Date installed 12/2/2010 Cleanouts (Y/N) Y High Water alarm (Y/N) Y System type Raised Bed Gravel below pipe .6 ft. Y Depression over field N .For · ' bedr°oms~ ~ gal. New depth in. Absorption rate >= g.p.d. If yes, give date LIFT STATION Date installed 12/2/2010 "Pump on" level at 4o Datum Bottom of Tank in. E. SEPARATION DISTANCES Size in gallons 500 "Pump ofF' level at 40 in. Cycles tested New Construction SEPARATION DISTANCES FROM VVELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >lOO' Public sewer main N/A Sewer/septic service line >25' Animal containment areas >50' Manhole/Access (Y/N) Y High water alarm level at 45 Meets alarm & circuit requirements? in. On adjacent lots >lOO' On adjacent lots >lOO' Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A > 100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Prope~q/line >5' Water main N/A Water service line >10' Wells on adjacent lots >lOO' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field >5' Surface water >1oo' Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water *54' Driveway, parking/vehicle storage, >25' Curtain drain None Noted Wells on adjacent lots >lOO' F, COMMENTS: *See Waiver to Surface Water. Right of ~!1~1 imm ~ .~e~,., ' -,~ v / ~ ~s~ / ~s~e de~e~ed ~ ~e/d/~s~e~/o~s s~d ~.. _ .~ ........ ~ ~n~ance w~h MOA COSA guidelines in effe~ on this date. ~~~~~ . Date 5/~2011 ~ r t~ ~ COSA Fee $ c~ ~:~ "~ ~, ~-"~- Waiver Fee $ Date of Payment ~--/~ //~ Date of Payment Receipt Number ~ ~/c/I ~ Receipt Number (Rev. 11/05) PLAT NO. 2004--91 RABBIT CREEK VIEW &:: RABBIT CREEK HEIGHTS SUBDIVISION REFILAT LOT 16A, BLOCK 5H 19,751 S.F. WELL \ \ · SEPTIC SYSTEM AS BUIL'F ~ H~-~-~,,, CERTIFY THAT'I.HAVE SURVEYED THE GASTALDI LAND PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY'OF'THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONs WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED 'SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR 5241/5341 1/21/2Oll ESTABLISHING. BOUNDARY' OR FENCE LINES. ANCHORAGE RECORDING D1S:'['RICT, ALASKA F.B. JOB NO. 10-09 RC15163H NOTE: NO .CORNERS SET 'THIS DATE. 1 "-30'