HomeMy WebLinkAboutEAGLE CREST #1 TR B LT 26ogle Cres, T act Lot 26 050- 291 -25 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: OSP101194 PID Number: O_~0 "2_ ~ [ - Name: CYNTHIA BEVERLIN Wastewater System: [] New [] Upgrade Address: 19112 SECOND ST.; EAGLE RIVER, AK 99577 ABSORPTION FIELD Phone: Number of Bedrooms: 229-4168 3 [] Deep Trench [] Shallow Trench [] Bed [] Mound F'lOther: LEGAL DESCRIPTION so, Rating: Total Depth from original grade: 0.8 GPD/Ft2 8 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: B 26 EAGLE CREST #1 3.5 Ft. 4 Ft. Township: Range: Section: Fill added above odginal grade: Gravel Length: 0.5 Ft. (2) @ 29 Ft.  Gravelwidth: Number of lines: I Distance between lines: Well: [] New [] Lpg 5 Ft. 2I 10 Ft. Classification (Private, A, B, C): Total Depth.'~.~.-'~'~" Cased to: Total absorption area: Pipe Material: _~~Ft. Ft, 580 Ft2 ASTM D3034 Driller: ~ Date Ddlled: Static Water Level: Installer: Date Installed: Ft. GUARANTEED SERVICES 9/27/2010 ~ GPM PumpSetat: Ft. CasingHeightAb°veGr°und:Ft. TANK SEPARATION DISTANCES [7'l Septic [] Holding [] S.T.E.P. []Other: T~To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: From% Tank Field Station Tank Sewer Line GREER 1000 Gal. Material: Number of Compartments: Well 123' 103' N/A N/A N/A Steel 2 Surface Water N/A N/A N/A N/A ~ ~ "~ ElectdcalLiFTinspectionsSTATiO..~~~_ performed by: ~in' Size: Manufacturer: Lot Line 55' 25' N/A N/A Gal. "Pump on" level at: .... in. High water alarm at: Foundation 45' 38' N/A N/A ~ Curtain Drain N/A N/A N/A N/A ~ Remarks: A 17' DEEP GROUNDWATER MONITORING PORT WAS BENCH MARK Location and Description: INSTALLED AT THE BEGINNING OF CONSTRUCTION (9/24/10). DOWNSTAIRS STEP Assumed Elevation: GROUNDWATER WAS NOT OBSERVED DURING 7-DAY TEST. Ft. 3.8 Engineer's Stamp - ',,'t."' ..... Inspections performed by: KURT MACKENZIE Dates: 1st 9-27-10 "..'.%'t! ~...: ......... '.... f 2nd 9-29-10 Development Services Departmertt ADDrOVal ~7/"~~ '~.' ~]'" ~ '~ r'~) te: /O ~f1,~'¢¢/:"... NO. 2162-CE..." (,~.Reviewed and approved by:l:,0o) ~..4 ; ..ye '~._. /¢'~' j-'C'~Da 1/~4~,~.~.; ....... /~/~,/, O0 I Oo (D Z Ld~ ~0 D 090 <~Z Z ~,,~ OZ ~0 z=~~ oo~~ O0 APPROXIMAqE lOCATION OF ~- ABANDONED 12'x15' SEEPA(;E PI7 LEGEND (M) © © i~Tkl GWMT FND YPC (KGL 52020 FND 5/8" RBR RECORD (PLAT 65-70) MEASURED CLEANOUT MONITORING TUBE WATER VALVE TEST HOLE PERC TEST GROUNDWATER MONITORING TUBE 2nd STREET S89'58'00"E 132.00'(R) S89'51'48"E 132.02'(M) Z 000 GAL. SEPTIC TANK ~RAVEL ~ DRIVEWAY~ / © © ® ® © NW HOUSE COR. SW HOUSE COR. TANK CLEANOUT TRENCH CLEANOUT TRENCH CLEANOUT LOT 27 LOT 34 NOTES: 1. AS-BUILT SURVEY WAS PERFORMED ON OCT. 05, 2010 LOT 26 17,8~2 S.F. 0.~1 AC, 10' UTILITY EASEMENT S89'58'00"E 132.00'(R) / S89'52'25"E 132.10'(M) LOT 55 /xO\0S ~~ SEPTIC SYSTEM LOCATION TABLE A B C 1 44.3' 4-1.7' 56.6' 2 63.0' 44.7' 55.9' _OT .o L07 56 15 0 ,50 GRAPHIC SCALE 1 "=30' ENGINEERS AND LAND SURVEYORS 801 WEST FIREWEED LANE SUITE 201 ANCNORACE, ALASKA 99505-1801 ATF' 1 Q/Q,~/DQ1 Q PHONE (907)-274 5257 ~ D, ,_~: ..... / .... ~ - EAGLE CREST ADDITION 1 (LOT 26 TRACT B) SEPTIC AS-BUILT - PLAN VIEW PREPARED FOR: CINDI TRAPP iDRAWN BY: RLW DATE: 10-8-10 'CHECKED BY: MLG JOB N0.:2010-1659 MOA GRID:NWO054 SCALE: 1"=50' FIELD BOOK:2010-02 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101194 05029125000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 EImore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: September 14, 2010 to September 14, 2011 Design Engineer: F ROBERT BELL & ASSOCIATES Subdivision: EAGLE CREST #1 Site Legal Address: EAGLE CREST #1 TR BLT 26 G:0054 Owner/Address: TRAPP CYNTHIA R 19112 SECOND STREET EAGLE RIVER AK 995777209 Site Mailing Address: 19112 SECOND ST, Eagle River Lot Size in Sq Ft: 17820 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The septic tank may not be located under the driveway. Construction of the drainfield may proceed prior to obtaining 7-Day water monitoring results at the owner's own risk. Water monitoring results shall be submitted with the Inspection Report. Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road t P.O. Box 196650 ~, Anchorage, Alaska 99507 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING P Parcel I.D. 05029125 Property owner(s) Donald & Cynthia Beverlin Day phone 907-561-2257 Mailing address 19112 Second Street Zip Code 99577-7209 Site address Same Zip Code Legal description (Sub'd., Block & Lot) Eagle Crest #1 (Tract B, Lot 26) Legal description (Township, Range & Section) T14N, RlW, Section 7 Lot Size 17,820 .Sq. Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR ([~ all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] I certify that the above information THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal ~ is correct. I further certify that this application is being made for a Single Fam-i!y Dwelling and is in accordance with applicable Municipal Codes. (Signature o/~roperty owner or auth~e~~a ent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: F. Robert Bell and Associates F. Robert Bell and Associates 801 W. Fireweed Lane, Suite 201 Anchorage, Alaska 99504 September 24, 2010 Re: On-site Septic Design Narrative - Eagle Crest First Addition (Lot 26, Tract-B) Development Services Department On-site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska 99507 To Whom It May Concern: Proiect Summary: A three bedroom house located on the property described as Lot 26, Tract B of Eagle Crest First Addition has a failing on-site septic system in need of replacement. The existing 1000 gallon and 500 gallon single compartment tanks will be replaced with a 1000 gal. dual compartment tank. Also, the existing deep trench will be replaced with two shallow trenches to the east. The property is currently served by public water and on-site sewer. Existinl~ system: The existing system consists of unidentified four inch piping routed from a cleanout near the NW corner of the existing house which travels NW approximately 45 feet to the location of the existing 1000 gallon concrete tank which is currently either failing or being bypassed completely. The line then continues to the west approximately :[5 feet where it connects to a 500 gallon steel tank. The line departs the steel tank to the west and south an additional 30 feet to the middle of the 42'L x 6'D deep trench septic field that lies 13 feet east of the western property line. Domestic Waste Water & Septic Desi/~n Calculations: Tank Size: 1,000 gal. min. for 3-bedroom house (AMC :[5.65.50) Design Daily Flow: 450 gpd (3 bedrooms x 150 gpd / bedroom) Percolation Rate: 9.41 min. per inch (per MOA on-site records) Application Rate: 0.8 gpd/s.f. (per AMC 15.65.060 Table 1) Absorption Area: 450 gpd + 0.8 gpd/s.f. = 562.5 s.f. · Type of Septic Field: "5-Wide" Shallow Trench Width=5ft · Depth = 4 ft · Reduction Factor = (W+2)/(W+:[+2D) = (5 ft+2)/(5ft+:[+(2x4 ft)) = 7/14 = 0.5 Length = (562.5 s.f. + 5 ft) x 0.5 = 56.3 ft = (2) 28.1 ft (Use two 28.5 ft trenches) WASILLA 1365 E. Parks HWY Suite #203 Wasilla, AK 99654 PH: (907) 357-5247 ANCHORAGE 801 W. Fireweed LN Suite #201 Anchorage, AK 99503 PH: (907) 274-5257 FX: (907) 743-3480 PRUDHOE BAY P.O. Box 340010 Prudhoe Bay, AK 99734 PH: (907) 659-5000 September 24, 2010 Construction of New Septic System: The concrete tank will be partially demolished and filled with sand and the steel tank will be removed completely. The new tank will be installed between the existing tank locations. New piping will be installed from the existing foundation cleanout to the new tank and then from the new tank to the two new drainfields. The existing drainfield will be replaced with (2) 28.S'Lx5'Wx4'D shallow trenches located 12 feet and 27 feet east from the existing drainfield. At start of construction a groundwater monitoring tube extending to a depth of 12 feet shall be placed near the proposed absorption trenches' location. If groundwater is encountered, all work shall be stopped and contractor shall notify engineer. The 100' well radius for the well on Lot 35, south of the project site, shall be located by a licensed surveyor prior to drainfield construction. When construction is completed, a COSA will be performed on the new system. All construction and demolition shall be performed to meet the minimum standards detailed in the current Anchorage Municipal Code (AMC) Chapter :15.65. The septic tank and piping shall be installed on undisturbed native soils or in trenches that have been adequately compacted. The service line shall not exceed the maximum allowable slopes. Cleanouts shall be installed on the service line, septic tanks, and lateral ends. A monitoring tube shall be placed in each trench. All cleanouts and monitoring tubes shall extend a minimum I foot above finished grade. Maintenance of Septic System: Routine maintenance shall be performed on the system, including pumping of the septic tank at least every two years. Using garbage disposals and flushing of non-degradable items (coffee grounds, cigarette butts, tampons, paper towels, etc.) should be avoided. The owner should limit heavy surface loads on the area to maintain the structural integrity of the system. Trees and other large plants should be removed and maintained at an adequate distance to prevent roots from growing into the system. Preventing vehicle traffic over the septic system is also encouraged. Please contact me with any questions. Sincerely, Frank R. Bell P.E./P.L.S. Attachments: · Engineered Plans (F. Robert Bell & Assoc.; September 24, 2010) 2 of 2 d- ~o 0 cq 0 ~ 0 o Z nO_ F- < Ld <{ 0 BE Z uO © 3N¥-I M31A / / / b 0 Z <( z 0 Z hJ O_ LJ LO OO 0 ZD Z< OLS Q~ L~ Z 0~ ~0 z ~Z 0 0 rr Q_(D~ O~ <( © C9 o ~.~'. ~: ,,: ~. .-~ / I ~ '.~ .. '.~'~. .' ~/ O0 Z LO 0 0 -- Z -- ~ I ~ ~ ~ LO 0 ~Z--~ ~ 0 ~0~ ~0 ~ O0 O~ ~ z Z ~o z ~E~S~ o So i 0 ~Z ~©0~~ ~Om© ©~2~ °Io ~ZD o ~<~ MUNICIPALITY OF F ANCHORAGE Development Services DepartmentPhone: 907-343-7904 On -Site Water & Wastewater Section �`V'� Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 050-291-25-000 Expiration Date: 9/25/2025 Legal description EAGLE CREST #1 TR B LT 26 Site address 19112 SECOND ST Eagle River AK 99577 Current property owner(s) ROUWENHORST JOHN L & LESLEY G The On-site system(s) is/are approved for bedrooms X Conditional approval for 3 bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 10/29/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF __� Development Services Department On -Site Water & Wastewater Section ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcell.D. 05029125000 Complete legal description EAGLE CREST #1 TR B LT 26 Location (site address) 19112 SECOND ST Current property owner(s) ROUWENHORST 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS Day phone 687-9757 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑Q Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: X Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 14 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ■❑ Wide Trench ❑ Seepage Pit Waiver request for: Distance: Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Date of Payment COSA# Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 COSA Checklist Legal Description: EAGLE CREST #1 TR B LT 26 Parcel ID: 05029125000 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system _ A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Measured operating fluid level in septic tank 50 Date of pumping 9/25/24 ❑ Required maintenance completed, if AWWTS Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 9/27/10 0 ALL standpipes present per record drawing Total measured depth from grade 9 ft (max) Measured depth to pipe invert from grade 5 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. 0 Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficienci COSA Checklist June 2022 Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes 400166 ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 9/11/24 Results Q Pass Fluid depth prior to test 28 in Water added 450 gal New fluid depth 35 in Elapsed time 30 min Final fluid depth 29 in Absorption rate 450 gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 48 Effective depth used 29 in Effective depth remaining 19 in in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' Z] Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' [:]Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' ❑ Yes if No ft ❑ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑ Yes if No ft 71 Yes if No ft ❑■ N/A— Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' ■❑ Yes if No ft Surface Water > 100'■❑ Yes if No ft Tank to Property Line > 5' ■❑ Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' ❑■ Yes if No ft Private Wells > 100' ❑■ Yes if No ft Water Main > 10'■❑ Yes if No ft Community Wells > 200' ❑■ Yes if No ft Water Service Line > 10' Q Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm NorthRim Engineering Engineer's Printed Namc Steve Eng COSA Checkpst June 2022 Phone 694-7028 Date 10/17/24 AV Ar0 0 49 IE �1 Steve Eng 644 7, �± GE -6256? Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. Expiration Date: ./ O GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Day phone Mailing address /o///~ Lending agency U/,J ~'4.~o W/,J Day phone Mailing address Real Estate Agent Mailing Address i.' Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: ~ Day phone TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site Individual Water Storage [] Individual Holding Tank [] Community Class ~ Well [] Community On-site [] Public Water System ~ Public Sewer [] The Municipality.,of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my. investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(arc) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ~ /~o~_/.- L'~FL'_~ ~ .,~5'~oC.,t,~-T'-~5 Phone ~oq -~7.'L/- 502.50 Address~oi ~/. F',,~-~'c.JF_-F_-C)L~. 5.~Z. ~.o/_f,,~,dC... ,'~K' 9~5°~ Engineer's Printed Name ~c-'t?. A-~ ~, /~b Date /© DSD SIGNATURE ~/ Approved for 3 Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11105) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other ~ ~' _o~'-'(~riginal Certificate Date: Municipality of Anchorage Development Servicea Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legalbescription:..~--~C~/__~ C~.¢_.¢'7" -/~ ~. ~/_,~ ~, ~-~B'CT-~ ParcellD: 050-,,q~/-~5 A, WELL DATA Well type IfA, B, or C provide PWSID # .., Well Log (Y/N) ~ Date completed Sanitary seal (Y/N). Wires properly protected (Y/N). ~ Total depth ft. Cased to ...____ff. Casing heigh~ in. Date of test FROM WELL LOG AT INRP~=-('~ t'3 ~_. I.._N Static water level ~ ft. . ft.  ft. Well production g.p.m. · Coliform ~.--~¢olonies/lO0 mt ~mg/t 'coloniesllO0 mt. Nitrate ~ ug/L date of sample:. B: SEPTIC/HOLDING TANK DATA Tank Type/Material ..~E Tank size ./o~o gal. , Foundation cleanout (Y/N) Date of pumping /~///~ C. ABSORPTION FIELD DATA Number of .Compartments Depression over tank (Y/N) Pumper ... Other bacteda Collected by: Date installed. Cleanouts (Y/N) High water alarm (Y/N) .~/ Date installect: ~/~?/'/c Soil rating (g.p.d.lft2 or ft2/bdrm)O,~ ~5~c ', ~', ~a ' ' Length (~)¢<~- fl. Width.. 5 fl. Total depth ~ ~'ff. ' Eft. absorption area 5~ ff~ Monitoring tube ~ Depression over field ~ Date of adequacy test ~ Results (Pass/Fail) ~ For ~ bedrooms Fluid depth in absorption field before test ~ in. Water added ~ gal. ' New depth ~ in. Elapsed Time: ~/~ min. Final fluid depth ~ in. Any rejuvenation treatment (past 12 mo.) (YIN & type) / System type" Gravel below pipe ~ ff. Absorption rate >=/~//A' g.p.d. If yes, give date ~,//~" · D. LIFT STATION Date installed "Pump on" level at ~ in. Datum ~ E. SEPARATION DISTANCES Size in gallons "Pump off" ~~. Cycles tested Manhole/A~~)~~/'- High water alarm level at in. Meets alarm & circuit requirements? ' SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot .... /,J//} Absorption field on lot *Public sewer main Sewer/septic service line /,/.//~ 'Animal containment areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation ~'-~ '~ Property line ..~.~ On adjacent lots.. ~//~ On adjacent lots ,,/.//~ Public sewer manhole/cleanout Holding tank /~///,~' Manure/animal excrete storage areas Absorption field Surface water Water service line Water main_~ /O 'Wells on adjacent lots Water main ~ 70 '~r SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~5 / Building foundation 3~ '~ Water Service line Curtain drain COMMENTS Surface water. Wells on adjacent lots Driveway, parking/vehicle storage ~.~' / G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name. F'O~c~J/Z ,~. GE.Z-~ Date COSA Fee $ ~ Date of Payment Receipt Number. /*'~..~ (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number LEGEND (R) (M) A FND YPC (KGL 5202L) FND 5/8" RBR RECORD (PLAT MEASURED UTILITY POLE TELEPHONE PED. COMM. PED. ELECTRIC METER GAS METER CLEANOUT MONITORING TUBE WATER VALVE LOT 27 2nd STREET N~ S89'58'00"W 132.00'(R) S89'51 '48"E 32.02'(M) LOT 26 ~o ~ 17,832 S,F. WOOD DECK ~ ~/ L Ol 25 ARBOR / ~ ~ ~ / OR~FNHOUSE =~ ASPLS MORTGAGE LOCATION SURVEY STANDARDS FOR LOT 26 TRACT B OF EAGLE CREST ADDN. 1 WAS MADE ON PREPARED FOR: CINDI TRAPP DRAWN BY: MLG CHECKED BY: BMW JOB NO.: 2010-1659 MOA GRID:NWO054 SCALE: 1"=50' FIELD BOOK: 2010-02, OCT. 05. 2010 AND THAT THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND DO NOT OVERLAP OR ENCROACH ON THE PROPERTY QUESTION AND THAT THERE ARE NO ~ [3 ROADWAYS, TRANSMISSION LINES OR OTHER WEST FIREWEED LANE SUITE 201 VISIBLE EASEMENTS ON SAID PROPERTY ~(N}IcHoRAGE. ALASKA 99505-1801 EXCEPT AS INDICATED HEREON. PHONE (907) 274-5257 ENGINEERS AND LAND SURVEYORS VAUL-I [] 10' UTILITY EASEMENT LOT .54 S89'58'00"W 152.00'(R) N89'52'25"W 1..'32.10'(M) ~-'T; OF ,~L~'\ Mo: ,55 s°~ , ,--- ~,% ... ~, tt - , .. ..... .,,?,,. ,.' ',~.- '-r,,,.,~-- ..... . ~ ! GRAPHIC SCALE INFORMATION CONTAINED HEREON SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE. OR OTHER IMPROVEMENTS. -/~ ~_ -. FRAN'K R. B'~LL o" ,--~ '~, THIS MORTGAGE LOCATION SURVEY WAS PREPARED FOR CINDI TRAPP, AND SHOULD ONLY BE USED f~,'~.'.,,'-. NO. 3252-,S .-',~,.~ FOR A S,NGLE PROPERTY TRANSACT, ON. RE-USE OF TH,S DRAW,NO BY THE ORIG,NAL CUENT OR I.~:¢,,,~ '... ..... .... ~%x~ ~ BY OTHERS FOR ADDITIONAL USES WITHOUT EXPRESS CONSENT OF F. ROBERT BELL AND '\{~(?~.~.¢8,0,~" ~.,~L,.~~ ASSOCIATES ISA VIOLATION OF THE FEDERAL COPYRIGHT LAW. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF F. ROBERT BELL AND ASSOCIATES SHALL BE LIMITED TO THE \~'~q,~,~.-~.'*'~ AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. HEREBY CERTIFY THAT A SURVEY WAS PERFORMED IN ACCORDANCE WITH THE F. ~ObeF~C-~