HomeMy WebLinkAboutTUXEDNI PARK WEST BLK 1 LT 7gob" X AM Tu wodri Ar m F -w AOL i WW" Municipality of Anchorage On-Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP1 91468 PID Number: 041-022-45 Dwelling: FR Single Family (SF) Fj with ADU ❑ Duplex (D) ❑ Two Single Family Project: FI-11 New F-1 Upgrade Name CHRISTOPHER MANION ABSORPTION FIELD 0 Deep Trench F-81 Wide Trench [] Bed ❑ Mound Site Address 9638 ATELIER DRIVE *ANCHORAGE, AK El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 716-388-2074 1 1.2 GPD/SFI 7 FEET MAX Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade SEE DWG Ft. Gravel depth beneath pipe 4 Ft. Subdivision Block Lot TUXEDNI PARK WEST; BLOCK 1, LOT 7 Fill added above original grade SEE DWG Ft. Gravel length 16.5 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 150+ Ft2 Ft. Well 100,+ 100'+ 1 00V+ 25'+ TANK 9 Septic El S.T.E.P. ❑ Holding 0 Other Manufacturer Capacity GREER TANK 1,000 Gal. Surface Water 100'+ 100'+ 10 0'+ Material Number of compartments Lot Line 5'+ 10'+ 51+ NA HDPE 2 Foundation 10'+ 10'+ 10'+ LIFT STATION Manufacturer Capacity Remarks ANCHORAGE TANK 76 Gal. Alarm location IN DWELLING Electrical installed by GLACIER ELECTRIC Installer PIPE MATERIAL House totank D3034 drainfield Tankto D1785 NORTHERN EXCAVATION Drainfield D3034 co/MTD3034 Inspector TIM ECKLUND AND DAVID GARNESS, PE BENCH MARK (Assumed elevation) 103.22 ft Inspection 1st 2/12/20 �d 2/19/20 dates: Location and description 2 t TOP OF MW 3`d2/19/20 4h 1 ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp k, OF Conditional Approval: Date 4 T en e� A ornest .' / '13 V EE-795 co Septic System Approved Date 10/1 5k&�C) Note: this approval does not include well permit requirements. #A CC884 Pro; sslo' tr<ev UO/UZI 1?5) .Ash PERMIT NUMBER: PARCEL ID NUMBER: OSP191468 RECORD DRAWING 041-022-45 A I B C ! / FCO 43.1 5.9 5.9Z `(i / / MH1 43.8 30.3 40.4 ��� / NEW DRAINFIELD ST1 45.3 34.7 44.9 O DBL1 46.0 35.9 46.1 / / 7 PV4.4 38.6 48.8 A MT1 71.6 65.0 74.3 P / C01 74.3 67.0 76.1 / _ — PUMP VAULT T2 MT2 65.7 68.4 78.8 f — CO CO2 63.6 66.2 76.7 / / / / DOUBLE 1 & 2MT O1 .H.#1 / :.••DRI�VEWAY�-' V / / • err-'t • \ H1 NEW 1 BEDROOM / HOUSE \ CO I \ \ 1 100' WELL RADIUS / N SCALE: 1"=40' �*\\\c lk 11 ���• Of 111 GARNESS ENGINEERING GROUP, Ltd 9 �'*10 ....::...........................::... ENGINEERING SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 701 -ANCHORAGE, AK 99507 -PHONE (907) 337L779 - FAX (907) 338-3246 - WEBSITE: vm+v.gamessengineenngcam e e e e � e � � e + ......... e e . . e . PREPARED FOR: PHONE NUMBER: PAGE NUMBER: �• %•, •• ,'�,.•� CHRISTOPHER MANION 716-388-2074 2 OF 3 �j %��3, r A. Garess w 1�% S CE- 96 =i LEGAL DESCRIPTION: DRAWN BY: #♦� �,•• 12�•�� TUXEDNI PARK WEST; BLOCK 1, LOT 7 D.J.G. 888 TYPE OF WORK: DATE: LICENSE 4444 ES" ���� � SEPTIC TANK AND DRAINFIELD RECORD DRAWING 5/4/2020 #AECC884 i PERMIT NUMBER: OSP191468 TOP OF TANK AT INLET= 95.08 - INVERT OF BUNG AT INLET = 94.37 TH RECORD DRAWING TOP OF MH = 10322 r— FINAL GRADE = 102.58 TOP OF MI -12 = 103.03 TOP OF TANK AT OUTLET = 95.09 PIPE INVERT AT INLET = 94.3 NEW 1000 GALLON H.D.P.E. GREER SEPTIC TANK RATED INVERT OF BUNG AT OUTLET = 94.30 FOR 10' BURIAL ORIGINAL GRADE AT HIGHEST POINT = 103.57 BOTTOM OF PUMP VAULT = 91.03 MT CO f- FINAL GRADE = 105.53-106.08 RELATIVE ELEVATION AT BOTTOM OF T.H. = 87.57 (GW AT 91.77 ON 2/18/20 - GWM ON 10/11/2019 AT 91.01 - LOWER THAN FEBRUARY) PER CONVERSATIONS WITH MOA, THE REQUIRED SEPARATION DISTANCE WILL BE FROM THE HIGH GROUNDWATER IN FEBRUARY WITHOUT THE 2' ADJUSTMENT FOR THE THEORETICAL HIGH GROUNDWATER MONITORING OF OCTOBER FILTER FABRIC INVERT OF PIPE = 100.57 BOTTOM OF TRENCH = 96.57 GARNESS ENGINEERING GROUP, Ltd CAI('-IAICr-DIKIf'- CAI CC flnKICI IITIAIt- 3701 E. TUDOR ROAD. SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 336-3246 • WEBSITE: w .gamessenginee PREPARED FOR: PHONE NUMBER: PAGE NUMBER: CHRISTOPHER MANION 716-388-2074 3 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: TUXEDNI PARK WEST; BLOCK 1, LOT 7 D.J.G. TYPE OF WORK: DATE: �, SEPTIC SYSTEM PROFILE RECORD DRAWING 3/24/2020 (?f'l' I S� PARCEL ID NUMBER - 041 -022-45 Certified Drilling L® ir ILI 111 OWNER OF LAND: Christopher Manion ADDRESS: 9638 Atelier Dr LEGAL DESCRIPTION Tuxedni Park West Blk 1 Lt 7 DATE: 1/14/2020 PERMIT OSP191468 DATE OF ISSUE: 10/22/19 NUMBER: TAX IDENTIFICATION 04102245000 NUMBER Is well located at approved permit location: ®Yes F—]No Method of Drilling: ®air rotary ❑cable tool Depth of Well: 144' Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 139 feet Liner type Static Water Level: Flowing feet Recovery Rate 6 ® gpm ❑ gph Method of Testing Air Well Intake Opening Type: © open end ❑open hole ❑ Screened Start feet Stopped ❑ Perforations Start feet Stopped Grout Type: Bentonite Volume: Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: ©yes ❑ no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 2 4 4 6 6 12 12 68 68 121 121 124 124 136 136 144 Casing Stickup Fill Overburden Silty Sand & Gravel Sand w/ Gravel Silt w/ Sand & Gravel Silty Sand & Gravel 1 GPM Tight Silty Sand & Gravel Sand & Gravel Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. Matsu Borough: Department of Environmental Conservation. Legal Description Property Owner Name & Address: t7elj �! moj- e-or A -fc e LER, V Pump Installation Date: Pump Intake Depth Below Top of Well Casing: 1,1`,o feet Pump Manufacturer's Name: Pump Model: Sbc% Q - Pump Size YZ lip Witless Adapter Burial Depth: 12, feet Witless Adapter Manufacturer's Name: "y Witless Adapter Installer: Well Disinfected Upon Completion? Z Yes Fj No Method of Disinfection: SAFZ— PC -CC Comments: Pump Installer Name: Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Z� heveloo ment Services bepartm-lent �a C li,Y d 9 e iv is; ori On -Site 141ater At Alasi wrra-ei, Prognam-, 0 1 4700 Elmore Rocd P.O. Box 19665,01 < V 4 Mark Begich Andhorege,AK, 99507 S A F r T Y Mayor (907%343-7904 Pump Installation Log Well Drilling Permit Number: 6 M, -LS � Date oflssue: Parcel Identification Num ber: � - 0? 1 ``�5 Legal Description Property Owner Name & Address: t7elj �! moj- e-or A -fc e LER, V Pump Installation Date: Pump Intake Depth Below Top of Well Casing: 1,1`,o feet Pump Manufacturer's Name: Pump Model: Sbc% Q - Pump Size YZ lip Witless Adapter Burial Depth: 12, feet Witless Adapter Manufacturer's Name: "y Witless Adapter Installer: Well Disinfected Upon Completion? Z Yes Fj No Method of Disinfection: SAFZ— PC -CC Comments: Pump Installer Name: Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Z� �.'pwoco Piton ier.+'1%+00+Ps.4 6--r To wewl Y CIPAUr`, Municipality of Anchorage Development Services Department P.O. Box 196650 - 4700 Elmore Road T Anchorage, Alaska 99519-6650 Info and Help: (907) 343-8211 °"�HOR►�` INSPECTIONS: Voice: (907) 343-8300 Fax: (907) 249-7777 5/11/2020 Inspection Report License/AP#: E19-2340 Parent AP#: R19-2751 Inspection #: 610744 Type: RES Status: Issued Address: 9638 ATELIER DR Parcel: 04102245000 Inspector: O.Burbridge P roj e ct: Resp Party: Descr: EXEMPT DETACHED SHOP WITH 1804 SQFT LIVING - MJDREVIEWED BY INDEPENDENT REVIEWING PROFESSIONALS MICHAEL ANDERSON AND TRAVIS JULIUSSEN Inspection ElecFin (Final Electrical) Item: Evaluation: Corrections Result Notes: some corrections made- septic system electrical install portion approved- see notes for remaining items Inspection Item Item Description =valuation 5/8/2020 Correct Below Corrected Code Ref: Location: Notes: electrical contractor performing work must assign permit to their license 5/8/2020 Correct Below Code Ref: Location: Notes: feeder from house to garage must be buried with minimum 2 feet of cover 5/8/2020 Correct Below Code Ref: Location: MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP191468 Work Type: WellSeptic Upgrade Tax Code Number: 04102245000 Site Legal Address: TUXEDNI PARK WEST BLK 1 LT 7 G:2042 Site Mailing Address: 9638 ATELIER DR, Anchorage Owner: MANION CHRISTOPHER J Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: ,�111�'I1j O� N, Y ` Department 10/22/2019 10/21/2020 146353 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received B� Issued By: Date: 10 /23 )],:i Date: Z r 1 MUNICIPALITY OF Community Development Department Development Services On -Site Water & Wastewater Program Parcel I.D. 041-022-45 ANCHORAGE On -Site Sewer/Well Permit Application For A Single Family Dwelling Property owner(s) CHRISTOPHER MANION Mailing address 6225 REDTOP CIRCLE "ANCHORAGE, AK Site address 6225 REDTOP CIRCLE "ANCHORAGE, AK Legal description (Sub'd, Block & Lot) TUXEDNI PARK WEST; BLOCK 1, LOT 7 Legal description (Township, Section & Range) Lot Size APPLICATION IS FOR: ( ® all that apply) Absorption Field Septic Tank Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Sq.Ft. Number of Bedrooms 1 (BEDROOM) APPLICATION IS AN: TYPE OF DEWELLING: Initial ❑ Single Family (SF) Upgrade ® (w/wo ADU) D ❑ Renewal El Duplex (D) Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: Distance: _- I I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. 05 P 10W_1�0g Waiver Fees: Date of Payment: Receipt Number: Waiver No. (Rev. 01 /11) GARNESS ENGINEERING GROUP, Ltd ENGINEERING o SALES o CONSULTING - I October 11 th, 2019 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic System Upgrade for ADU on Tuxedni Park West; Block 1, Lot 7 To whom it may concern: The subject lot is served by a private well and septic system. The homeowner is looking to construct an ADU on property that will require an additional private well and septic system. We are proposing to install a new 1000 -gallon HDPE septic tank and 5 -wide trench type drainfield. One testhole as excavated on the lot and the drainfield is designed within its 30 -foot radius. Comments regarding the design are summarized as follows: 1. SOILS: See attached 2019 testhole by Garness Engineering Group, Ltd. which shows the soil classifications, percolation test, and groundwater monitoring. A soil sample was pulled and submitted to a certified lab for a sieve analysis. As can be seen on the attached soil log, the visual classification was an SP (later classified as SM after sieve), and the soils percolated faster than 1 min/inch. In short, due to the visual classification and sieve analysis, a sand filter should not be required. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: There are no topography concerns. We are unaware of any adverse impacts this installation will have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. A Since teIy, /] , k. E., M.S. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com PARK LOT BLOCK 1, LOT 10 1 14 {EDNI PARK WEST ROW ACQUISITION PLAT; BLOCK 2, LOT 2 �\ TRACT A 1 1 I \ I I oJ5 I TUXEDNI PARK WEST; BLOC Z LOT.9I/ �// �� \\ O / 100' W DI I N" SEPTIC AREA I i TUXEDNI PARK WEST\ BLOCK 1, LOT 6 \\ / \X 0 LL RADIUS / I I 1 VACANT TUXEDNI PARK WEST; BLOCK 3, LOT 6 {EDNI PARK WEST; BLOCK 3, LOT 5 VACANT TUXEDNI PARK WEST; BLOCK 3,LOT 4 — I� I/ II / TUXEDNI PARK WEST; I BLOCK 3, LOT 3 GARNESS ENGINEERING GROUP, L ENGINEERING: SALES - CONSULTING :---- 3701 E. TUDOR ROAD, SUITE 101 *ANCHORAGE. AK 99507' PHONE (907) 337.6179' FAX (907) 338-3246' WEBSITE: v .aamessenaineerina nam PREPARED FOR: PHONE NUMBER: PAGE NUMBER: CHRISTOPHER MANION - 1 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: TUXEDNI PARK WEST; BLOCK 1, LOT 7 D.J.G. TYPE OF WORK: DATE: �.- SITE PLAN 10/10/2019 N I \I I I I v�0\JS SCALE: � 1" = 100' / 0FiVAi °! Q . >A, 4� �0 �.....'............................'..... � 0 i . . . ....................�... 1 Je rj�y . Game s :== ♦� Z i CE- AV LICENSE °°1\lklk"**•�•• #AECC884 \ c9s \ \ F Liv DESIGN CRITERIA: / NUMBER OF BEDROOMS: 1 GALLONS PER DAY (GPD): 150 GPD — PERCOLATION RATES: <1 MIN/INCH �• f PROPOSED APPLICATION RATE: 1.2 GPD/BEDROOM S IZL� C�l� MINIMUM DRAINFIELD SQ.FT.: 125 FTI DRAINFIELD DESIGN: N MAXIMUM DEPTH: 8 FEET WIDTH: 5 FEET LENGTH: 15 FEET EFFECTIVE: 4 FEET SCALE: REDUCTION FACTOR: 0.50 ACTUAL SQ.FT.: 150 FTI 1"=40' MOA APPROVEDD FILTER., NA IVE \a\ 1t♦AV♦ - --- -- — GARNESS ENGINEERING GROUP, Ltd • *' -- ENGINEERING c; SALES CONSULTING _— ---- 0 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 337-6179 -FAX (907) 338-3246' WEBSITE: w .gamessengineering.wm•• ll ••........../. • .. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: (n • ,f2 •••••G8f SS••: CHRISTOPHER MANION 716-388-2074 2 OF 2 �j�,'�•l� CE -79 3 =AV AV PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦♦ �` ••.,� ••�• TUXEDNI PARK WEST; BLOCK 1, LOT 7 D.J.G. ♦1�c�Q p••P�, sem• TYPE OF WORK: DATE: 1 0 b y. / /1� O I-• S16t 4: SEPTIC TANK UPGRADE DESIGN 4A J� �' # LICENSE ��11's's GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER NOTE: CONTRACTOR MUST HAVE ALL 100' WELL THAT PERTAINS TO THIS DESIGN. BY PROCEEDING NOTE: THERE WERE NO SURFACE WATERS RADII SHOWN, AND THE EAST, WEST, AND NORTH FORWARD WITH THIS INSTALLATION, THE OBSERVED DURING GEG SITE VISITS IN THE OPEN LOT LINES FLAGGED BY A PROFESSIONAL LAND ENGINEER, WELL DRILLER, CONTRACTOR AND CHANNELS NOTED ON THE MOA WETLANDS MAP SURVEYOR PRIOR TO CONSTRUCTION AND PROPERTY OWNER AGREE THAT THEY HAVE WHEN OUR GEG EMPLOYEE WALKED THE AREA ENGINEERS LAYOUT. READ THESE SPECIFICATIONS AND AGREE TO ON 10/1/19. ACCEPT THE TERMS AND CONDITIONS OUTLINED. s/ / n / PROPOSED DRAINFIELD XN MT i DBLICO'S COM ` RESERVED DRAINFIELD •1•• ••w •v \ RIV�VjlAY •;'DTH ��/�� ..r \ O ^-•"yam•, ST / _ • :' MH PROPOSED WE L FCO PROPOSED \ 1 BEDROOM TOPOSED 1,000 GALLON ADU ' GREER TANK \ \ /'ROpOS \ \ ED loon, wEL' RADII,, \ c9s \ \ F Liv DESIGN CRITERIA: / NUMBER OF BEDROOMS: 1 GALLONS PER DAY (GPD): 150 GPD — PERCOLATION RATES: <1 MIN/INCH �• f PROPOSED APPLICATION RATE: 1.2 GPD/BEDROOM S IZL� C�l� MINIMUM DRAINFIELD SQ.FT.: 125 FTI DRAINFIELD DESIGN: N MAXIMUM DEPTH: 8 FEET WIDTH: 5 FEET LENGTH: 15 FEET EFFECTIVE: 4 FEET SCALE: REDUCTION FACTOR: 0.50 ACTUAL SQ.FT.: 150 FTI 1"=40' MOA APPROVEDD FILTER., NA IVE \a\ 1t♦AV♦ - --- -- — GARNESS ENGINEERING GROUP, Ltd • *' -- ENGINEERING c; SALES CONSULTING _— ---- 0 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 337-6179 -FAX (907) 338-3246' WEBSITE: w .gamessengineering.wm•• ll ••........../. • .. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: (n • ,f2 •••••G8f SS••: CHRISTOPHER MANION 716-388-2074 2 OF 2 �j�,'�•l� CE -79 3 =AV AV PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦♦ �` ••.,� ••�• TUXEDNI PARK WEST; BLOCK 1, LOT 7 D.J.G. ♦1�c�Q p••P�, sem• TYPE OF WORK: DATE: 1 0 b y. / /1� O I-• S16t 4: SEPTIC TANK UPGRADE DESIGN 4A J� �' # LICENSE ��11's's GARNESS ENGINEERING GROUP, Ltd ENGINEERING o SALES o CONSULTING " 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507' PHONE (907)337-6179 ' FAX (907) 338-3246' WEBSITE: v gamesseagi.e.mn .cam SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: TUXEDNI PARK WEST; BLOCK 1, LOT 7 PERFORMED FOR: CHRISTOPHER MANION DATE: 10/4/2019 DEPTH (feet) ORG 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 TEST HOLE #1 SOIL CLASSIFICATIONS DEPTH TO DATE GROUNDWATER 14' 10/4/2019 12.5' 10/11/2019 SITE PLAN � ! Q �` `v Q Pc' N SCALE: 1"= 100' DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 10/11/2019 ABSORBED 6 INCHES IN LESS THAN 3 MINUTES 6 TIMES 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. TEST RUN BETWEEN 3 FT. AND 4 FT. 6 (INCHES) 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES E NO SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: DAVID GARNESS (.OMMFNTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERF RM IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: i 111111111 Ma 11111!11 NIIII • ..'., IIIIIIIII If��1���i YH� • DEPTH TO DATE GROUNDWATER 14' 10/4/2019 12.5' 10/11/2019 SITE PLAN � ! Q �` `v Q Pc' N SCALE: 1"= 100' DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 10/11/2019 ABSORBED 6 INCHES IN LESS THAN 3 MINUTES 6 TIMES 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. TEST RUN BETWEEN 3 FT. AND 4 FT. 6 (INCHES) 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES E NO SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: DAVID GARNESS (.OMMFNTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERF RM IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: i M A N CD m 0 Co CD CD CD D 0 0 2) co CD v N v cn CO U7 O W m 0 N 0 Co 00 4 O 0 E 0 N CD O O O 1 O O O 3 -n m Percent Passing by Weight 0 tV W P cn rn -4 00 CD n m 0 0 O O O o 0 0 O 0 O 0 N N � r' 3 --NN«• 3/4•• 1/2•• z CO) J/21 0 ,/4. m Q. CL X #s m� #10 Gi #16 CD #20 #30 #40 #50 #60 #100 #200 N tO f0 I � T 1 4 0 j CD O W CD O m V O O t0 O O O CD' O Q1 O O COOO O W O N -4 v M O O O O � W N y m O I 1 M —C—C CCCCCC C� CLCD C�CCCC-�_C- CLCLC.F41 C - T CCCC C C LC i _L_ - - I N � r' 3 --NN«• 3/4•• 1/2•• z CO) J/21 0 ,/4. m Q. CL X #s m� #10 Gi #16 CD #20 #30 #40 #50 #60 #100 #200 0 �s.m m rr CL CD N L) Cn o W — o co 3 co m o vi (D co N CD co m 0^ YJ O C U) 0 N N r Q Y/ N m _a r7� Cr 0 3 N tO f0 I � T 1 4 0 j CD O W CD O m V O O t0 O O O CD' O Q1 O O COOO O W O N -4 v M O O O O � W N y m O I 1 M 0 �s.m m rr CL CD N L) Cn o W — o co 3 co m o vi (D co N CD co m 0^ YJ O C U) 0 N N r Q Y/ N m _a r7� Cr 0 3 Municipality of Anchorage Development Services Department Building Safety Division - On -Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: OSP101230 PID Number: 041-022-45 Name: Christopher J. Manion Wastewater System: ❑✓ New ❑ Upgrade Address: 3864 Lincoln Ellsworth Court #A Anchorage, AK 99517 ABSORPTION FIELD Phone: Number of Bedrooms: 250-1860 6 V Deep Trench ❑Shallow Trench El Bed ❑ Mound ❑Other LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 1.2 GPD/Ft' 11.5-12 Ft. Block: 1 Lot: 7 Subdivision: Tuxedni Park Depth to pipe bottom from original grade: Gravel depth beneath pipe: tvr' 4.5-5 Ft. 7 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 0-1 Ft. 54 Ft. Well: ✓❑ New ❑ Upgrade Gravel width: Number of lines: D . istance between lines 3 Ft. 1 Ft Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material Private 175 Ft 100 Ft 756 Ft= ASTM D3034 PVC Driller: Dale Drilled: Static Water Level: Installer. Date Installed. Alpine Drilling 6/13/11 41 Fl Red Dog Excavating 11/3-5/2010 Yield: Pump Set at: Casing Height Above Ground: 20 GPM 174 Ft. 1 >2 Ft. TANK SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ubliGPrivate Manufacturer. Capacity. From Tank Field Station Tank Sewer Line Anchorage Tank 2,000 Gal. Well >100' >100' N/A N/A >25' Material: Steel Number of Compartments: Two (2) Surface Water >100' >100' N/A N/A LIFT STATION Size: Manufacturer Lot Line >5. >10' N/A N/A Gal. "Pump on" level at: "Pump off" level at: High water alar at: Foundation >5' >10' N/A N/A in. in. in. Curtain Drain None Noted Pump Make & Model Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: Garage Slab. Assumed Elevation: 100.0 Ft Inspections performed by: A. Harala Dates: 1St 11/3/2010 .`"► 46 1 ;% � 2nd 11/4/2010 Development Services Department Approval Conditional Approval Date:' Reviewed ���SS���NA' and approved b : !/(/ CTS/ Date:U-2-7-1 pP Y ►o i MunicipaIity of Anchorage F DEVEOPMENT SERVICES DEPARTMCNT Permit Number; OSP101230 4700 South Bragaw Street Anchorage, AK. 99599-5555- ,13-7904 i-; ,. ;:, ;41-022.45 PLAT NO. 2004-155 PARK WEST SUEDIVISIO.N LOT 7, BLOCK 1 % PLAN AS-131JIL_T SCALE 1" = 30' F..�ZSJ. H 845' 12.34' rl V -_ TUXEDNI X20.49' VU r �}1 00 �V J / -IN ec.. ry tl ti/ b/ A pY Mv, s4 \ 1 t si R 1 ! a PLAT NO. 2004-155 PARK WEST SUEDIVISIO.N LOT 7, BLOCK 1 % PLAN AS-131JIL_T SCALE 1" = 30' F..�ZSJ. H 845' 12.34' rl V -_ -,11,7 4 r �}1 00 -IN ec.. Municipality of Anchorage 3 of 3 DEVEOPMENTSERVECESDEPARTINFENT 11, 4700 South Bragaw Street Anchorage, AK. 99519-660' sA3-7904 On -Site Wastewater Disposal System or Well Inspecti n F2epeit Permit Number: OSP 101230 Pl0 r1c. 041-022-45 U iorno PROFILE AS -BUILT No Scale v � ... Permit Number: On -Site Water & Wastewater System Permit OSP101230 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Tax Code Number: 04102245000 Work Type: WellSeptic Initial Permit Effective Dates: October 06, 2010 to October 06, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: TUXEDNI PARK WEST Site Legal Address: TUXEDNI PARK WEST BILK 1 LT 7 G:2042 Owner/Address: MANION CHRISTOPHER J 3864 LINCOLN ELLSWORTH CT #A ANCHORAGE AK 995172355 4'eB... //_3 -ID h—q —7a Site Mailing Address: 6225 REDTOP CIR, Anchorage Lot Size in Sq Ft: 146353 Total Bedrooms: 6 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage /.'3-0 I Z'. 0") All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. A cross section of the drainfield and any slopes >25% within 50 feet down gradient of the drainfield shall be submitted with the Inspection Report. C0� ,n�pde5 ��e We I ), 0-T • !�lal�o Received I Issued By: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) October 5, 2010 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 1, Tuxedni Park Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The owner of Lot 7, Block 1, Tuxedni Park Subdivision intends to construct a new six - bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicate sitly gravel with sand (GW/GM). The percolation rate of the soil was determined to be 4.4 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 2,000 -gallon septic tank and a 54' long by 3' wide by 7' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 10'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the north. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be Lot 7, Block 1, Tuxedni Park Subdivision October 5, 2010 Page Two constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, C� Michael E. Anderson, P.E. Attachments Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 041-022-45 Property owner(s) Harding Homes of Alaska, Inc. Day phone 250-1860 Mailing address 5771 Heritage Heights Drive Anchorage, AK Zip Code 99516 Site address 6225 Redtop Circle Anchorage, AK Zip Code 99507 Legal description (Sub'd., Block & Lot) Lot 7, Block 1, Tuxedni Legal description (Township, Range & Section) Lot Size 146,353 Sq. Ft. THIS APPLICATION IS FOR (® all that apply) Absorption Field 7 Septic Tank 0 Holding Tank ❑ Privy ❑ Private Well E Water Storage ❑ Number of Bedrooms six (6) **PG �40 THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: -73 0 Date of Payment: ® 61? q Receipt Number: `� S ' / CJ (Rev. 11/05) Date of Payment: Receipt Number: I/ r. LOT 7, BLOCK 1, TUXEDNI PARK WEST SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Six Bedroom Home Deep Trench System Perc. Rate: 4 Min./Inch 2,000 Gallon Septic Tank Application Rate: 1.2 GPD/SF 7' Effective Depth 6 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/14 SF/LF = 53.6 LF Trench Length THEREFORE: Construct a 54' Long x 3' Wide x 7' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 10' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Natural Backfill 2'6" Geotextile Fabric 6" (� 4" Perforated I} PVC (Holes Down) Drainfield Rock T0" 3' TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 1 00'Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1- 2- 3- 4- 6- 7- 8- 9- 10- 11 1 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 7, BLOCK I, TUXEDNI PARK WEST PERFORMED FOR: HARDING HOMES DATE: 9/23/10 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA TEST HOLE 1 OB/OG SILTY GRAVEL WITH SAND GW/GM SLOPE SITE PLAN SEE SITE PLAN k 11 WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? NET TIME (MINUTES) WATERO (INCHES) DEPTH OF WATER AFTER MONITORING: NONE TEST HOLE PRESOAKED PRIOR TO TESTING: DATE OF MONITORING: 10/3/10 2:23/2:33 10 4.63"/7.00" DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATERO (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/3 1 2:23/2:33 10 4.63"/7.00" 2.37" 2 2:34/2:44 10 4.50"/6.75" 2.25" 3 2:45/2:55 10 4.50"/6.75" 2.25" 4 1/311 10 4.25"/6.50" 2.25" 5 3:12/3:13 10 3.63"/6.00" 2.37" 6 3:15/3:25 10 3.50"/5.75" 2.2511 PERCOLATION RATE: 4.4 (MIN/INCH) PERC. HOLE DIA. 6�INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST, TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/4/2010 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 1, TUXEDNI PARK WEST SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 2,000 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 54' long X 3' wide X 7' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 3' below the existing ground surface. Total depth of the trench will be 10' below the existing ground surface. The new absorption trench and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area and 10' from the water service line proposed for the lot. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 2,000 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 7, Block 1, Tuxedni Park West October 4, 2010 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 7, Block 1, Tuxedni Park West October 4, 2010 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A. B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Development Services Department Building Safety Division On -Site Water & Wastewater Program o <o 4700 Elmore Road z z P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: Date of Issue: lri Parcel Identification Number y/o�,�2 q/ )0--.o Legal Description Property Owner Name & Address: Y L Pump Installation Date: Pump Intake Depth Below Top of Well Casing: I' feet Pump Manufacturer's Name: .. a,,,y F �,- Pump Model: Pump Size j hp Pitless Adapter Burial Depth: I feet Pitless Adapter Manufacturer's Name: z Ff --., , , /r: Pitless Adapter Installer: Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: r Comments: Pump Installer Name: Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Alpine Drilling & Enterprisi.:s Well Log Permit\uatber:HSWOSP101230 Date of lssue: 10-6-10 Parcel luetrtificotiortNumber:410'.'.' <5:� Datc Started; 6-12-11 Date Completed; 6-13-11 Is w6f located m aprnovcd permit locarion? x 1'es Legal Description: Tuxedni Park West BA, 1 Lot property Owner Name & Address: Manion Christopher 3864 Lincoln Ellsworth Ct Borehole Data: Depth (ft) Snail Tt pc, Thickness & Water suaua From To sock -up viii >�nu9r�+crvellh cilr s; 11 t'+Al'1S'.Sihl' �(71'tlPel rt dPOCk _qtr 0 2 4 32 41 47 S5 94 97 163 WATER QUALITY TESTING Coliform CU Col/10®mL Nitrates 1, S mg/L Arsenic ug/L 4 32 41 4; SJ 94 9_1 188 1%i Method of Drillino a mi rotary ❑ c;11>I< m"' --_- Casin;; type: sr�r;. Well Thfc-kness:.'Jo_ iuuhcs Diameter: 6 inches Dcpth_ N}o fcct IJ ncr Ty pe: _ Diameter: __ incites Depth: _ feet Casing stickul)c' ,round::' 12c.'t static water Icvcl (iFoin ground lcv-`clj: 1 r; llumphigleveC bR leelAc-r 2 houri pumping _r�_. epm Recovery Rate 20_ npm Nlellro(I of Icstin;": air lilt Well lntakc Opening Type; ❑ Opcn Fad s Open I lole Ci SClocilc"I pert !ccl S � � tl ._ Pe;fbn trans Start tcc[ SI ped tzruut tvpc:wf; �ianures roiucr::. p Pump: NlAkc Dr�ih _ f'ex: Pump size ---- rq:� drr:nd Natr;i- it Well Disinfected C1)011 Completion? c YQ b'I Clhud of 7)is in th:.t ion: ebkn'inr lul:ir,v Comments: — _... Well Driller: 71- i.e Utrllmg& Erin; =+:[e, c � 0,490 i i ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: October 30, 2012 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 7, Block 1, Tuxedni Park West Subdivision Septic System Inspection Report COSA The area over the septic system was regraded this past summer. Grass turf was then placed in the area. Final grading has been completed and is acceptable. We hereby request the unconditional COSA be issued. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. Location (site:ad Current Property owrle� Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 4w, COSA # - -I . f a 10 ,�V( Expiration Date: 3 7 - /S 7, Block 1, Tuxedni Park West Subdivision Top Circle Anchorage, AK J. Manion Day phone 350-1860 3864 Lincoln Ellsworth Court #A Anchorage, AK 99517 Unless otherwise requested, COSA will be held by DSD for pickup. Day phone Day phone 2. NUMBER OF BEDROOMS: six (6) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ✓❑ Individual On-site ❑✓ Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson 5. DSD SIGNATURE Approved for Disapproved. bedrooms. Phone 522-7773 Date 10/30/2012 Conditional approval for bedrooms, with the following stipulations: Attachments COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineers Report Other By: Original Certificate Date: /a -.7,7-/2—, (Rev. 11105) Municipality of Anchorage • •.t 1 f L (!FM pment Services Department p� Building Safety Division n -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 4.¢-Je s t 4.17 Individual Water Storage o- 4.¢-Je s t CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 041-022-45 31. GENERAL INFORIU[ATION Complete Legal description Lot 7, COSA # 5(o Expiration Date: !7 1 % Block 1, Tuxedni Park West Subdivision Location (site.addrpds) 6225 Red Top Circle Anchorage, AK Current Property..owner(s) Christopher J. Manion • se. Day phone 350-1660 ` Nlailit�g address 3864 Uncoln Ellsworth Court 4A Anchorage, AK 99517 Lending agency Mailing address Real Estate Agent.; , M.Ailing,Address Unles�,otfa'envisexeguested, COSA will behold by DSD for pickup. 2. NUMB&OF BEDROOMS: six (6) 3. TYPE OF WATER SUPPLY: Individual Well 4.17 Individual Water Storage ❑ Y`a4`c; 1- YYYf Public Water System ❑ C. SAICYY CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 041-022-45 31. GENERAL INFORIU[ATION Complete Legal description Lot 7, COSA # 5(o Expiration Date: !7 1 % Block 1, Tuxedni Park West Subdivision Location (site.addrpds) 6225 Red Top Circle Anchorage, AK Current Property..owner(s) Christopher J. Manion • se. Day phone 350-1660 ` Nlailit�g address 3864 Uncoln Ellsworth Court 4A Anchorage, AK 99517 Lending agency Mailing address Real Estate Agent.; , M.Ailing,Address Unles�,otfa'envisexeguested, COSA will behold by DSD for pickup. 2. NUMB&OF BEDROOMS: six (6) 3. TYPE OF WATER SUPPLY: Individual Well 0 Individual Water Storage ❑ Community Glass Well ❑ Public Water System ❑ Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑✓ Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality.of.An4horage. Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin J. Schiller, P.E. 5. DSD IGNATURE Approved for (� _ bedrooms. Disapproved. Conditional approval forbedrooms, with the following stipulations: Phone 522-7773 Date 3/1/2012 . oen)artin j Schiller 3'•, CE.1592 ', 4�\������ Attachments: COSA Checklist Septic System Advisory Well Flow Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report )ther (Pa 11105) Original Certificate Date: Municipality of Anchorage IL CUP, , € , Development Services Department Building Safety Divisions c+ On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 7, Block 1, Tuxedni Park West Subdivision Parcel ID: 041-022-45 A. WELL DATA Well type Private If A, B, or C provide PWSID # — Well Log (YIN) Y _ Date completed 5/93/11 Sanitary seat (Y/N) Y Wires properly protected (YIN) `y Total depth n5 ft. Cased to 100 ft. Casing height (above ground) 124 n, FROM WELL LOG AT INSPECTION Date of test 5/13/11 Static water level 41 Well production 20 9 RM g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 1.57 mg/L Other bacteria 0 colonies/to:) mL Arsenic: N/D mg/I Date of sample: 12/1/11 Collected by: A. Harala B. SEPTICIHOLDING TANK DATA Tank Type/Material SeptidSteel Date installed 11/3/2010 Tank size 2.000 gal. Number of Compartments Two Cleanouts (YIN) v Foundation cleanout (YIN) Y Depression over tank (YIN) N High water alarm (Y/N) N _ Date of pumping New Construction Pumper NIA C. ABSORPTION FIELD DATA Date installed 1113-cd2010 Soil rating (g.p.d.M2 or ftz/bdrm ) 1.2 GPD/SF System type Deep Tranch Length 54 ft. Width 3 ft. Gravel below pipe 7 Total depth 12.13 ft. Eff. absorption area 756 ft2 Monitoring tube Y Depression over field N Date of adequacy test New const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added_ gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g PA. Any rejuvenation treatment (past 12 me.) (Y/N & type) N If yes, give date s P r � L l�]��I��-•iY_\�hlil Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at —in, "Pump offlevel at_ in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100 Public sewer main N/A Public sewer manhole/cleanout NIA Sewer Iseptic service line >25' Holding tank N/A Animal containment areas >57 Manure/animal excrete storage areas >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >T Property line >5 Absorption field >5' Water main N/A Water service line >10' Surface water >100' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >25 Curtain drain gone Noted Wells on adjacent lots >100' F. COMMENTS: G. ENGINEER'S CERTIFICATION I certify that i have determined through field inspections and 49i iHT YA review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. m ';�?� ;8enjanl ::J•ScFw!er P'^••^ Engineer's Printed Name Benjamin J. Schiller, P.E. A- T CE-1 592 w s d JlJ ,Date 3/1/2012 0�9�',I 2 •'���� ► � ¢ pROFF55VONP�®� CO C Ovid, Ovlµ I COSA Fee $ ���. <4 l O O Waiver Fee $ _ Date of Payment 3l2�� '012 Date of Payment Receipt Number d qG Receipt Number (Rev. 11105) � \�\ 0 t -A / A .0. 0 t -A