HomeMy WebLinkAboutTHE LANDINGS BLK 1 LT 4The Landings Block 1 Lot 4 #020-061- 1 1 Municipality of Anchorage e Development Services Department e Building Safety Division Onsite Water & Wastewater Program, 4700 Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 Page 1 3 of Onsite Wastewater Disposal System and/or Well Inspection Report Permit Number: OSP101224 PID Number: 020-061-11 Name: WAYNE ELLIS Wastewater System: ■ New ❑ Upgrade Address: 16045 HYANNIS CIRCLE *ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) N/A 3 []Deep Trench ❑ Shallow Trench ■ Bed ❑ Mound ❑ Other LEGAL DESCRIPTION Soil Rating: 2.0 Total Depth from original grade: GPD/Sq. Ft. 1 FOOT ABOVE O.G. Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 1 4 THE LANDINGS SEE DWG. 0.52 Ft, Ft. Township: Range: Section: — Fill added above original grade: (ravel length: — — 4+ Ft. 20 Ft. WELL. ® New ❑ Upgrade Gravel width: 15 Number a lines: 3 Distance between lines: 5 Ft. Ft. Classification (Private, A,B,C): Total Depth: Cased To:teEMiadc) Total absorption area: Pipe material: PRIVATE 380 Fl 55 n 300 so. Ft. D 3034/ F-810/SCH 40 Driller. HEFTY DRILLING Date Drilled: 4/28/11 Static Water Level: 83 Installer. WILCO CONTRACTORS Dote installed: 6/24-28/11 F Yield: Pump Set At: Casing Height Above Ground: 3 350 2 TANK GPM Ft. Ft. SEPARATION DISTANCES 0Septic EI Holding MS.T.E.P. ❑Other* TO From Septic Tank Absorption Field Lift Station Holding Tank Public/Private Sewer Lines Manufacturer. GREER Capacity In gallons: 1500 Well 100'+ 100'+ 100'+ — 25 + Material: STEEL Number of compartments: 2 Surface Water 100'+ 100'+ 100'+ - - LIFT STATION Lot Line. 5'+ 10'+ 10'+ — — Size in gallons: Monufacturer: 1500 GREER QUANICS Foundation 5'+ 10'+ 10'+ — — "pump on level at: "Pump air level at: 1 High water alarm at: TIMER TIMER 46 Curtain Drain NONE KNOWN Pump Make & Model: I Electrical Inspections performed by. P—FE-41T M.O.A. Remarks: THIS IS A QUANICS AEROCELL SYSTEM BENCH MARK Location and Dexription: moqetabd. 4 1: vl 11- BOTTOM OF SIDING NW SIDE OF HOUSE Assumed Elevation: 100.00 Fr Inspections performed by: GEG, Ltd. Dates: 1st 6/24/11 ENGINEEWS SEAL 006000 2nd 6/27/11o OF �F . • ......... qs�0 3rd x/27/1 1 �0 Q . �0 Developmept Servi s D partment Approval o � 49 p.............. ..... 0 / D Conditional approval: _ Date: 1144 / D D / 6 eff A. ness. Q O�O w { G /S y, '. E-7153 � �O ce0 few f•I' �d�4"° Reviewed and approved by: Date: I -i 9' 1 (Rev. 4/06) ��d Prof �4 ressiorl \ 000006 PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: OSP101224 020-061-11 i SEPTIC PIPE Y / D' 10 x FATR� FCO 24.47 16.53 ST1 15.71 48.71 MH1 24.13 56.56 POD 1 36.19 68.69 POD 2 35.00 68.79 MT1 39.39 177.10 C01 38.67 176.26 CO2 39.51 174.54 CO3 41.081 73.31 C04 60.72 93.62 MT2 59.19 92.49 C05 59.91 94.71 C06 59.05 95.80 C07 42.30 78.59 LOT 3, BLOCK 1 THE LANDINGS S/D � v NEW BED / C04 •r �� C052 \ 03 f650 AEROCELL �•� I C2 UNIT � :. NEW 1500 GALLON STEP MT 1 MH TANK ST1 FC V. USE OF RESERVE DRAINFIELD WILL REQUIRE 9 \ RE-ROUTING OF DRIVEWAY. O `Al` LOT 5, BLOCK 1 N \ THE LANDINGS S/D PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: - OSP101224 020-061-11 FINAL GRADE = 99.19-99.54 TOP OF TANK INLET = 94.19 INVERT OF BUNG INLET = 93.59 - 1500 GALLON 10 GAUGE STEEL - DEEP BURIAL S.T.E.P TANK 4" INSULATION - FINAL GRADE 100.22-100.23 ORIGINAL GRADE = 96.13 HIGHEST POINT 650 AEROCELL POD W/ INTERNAL JANDY VALVE - TOP OF TANK OUTLET = 94.17 2" INSULATION -FILTER FABRIC TO DRAIN FIELD TO BE TOPSOIL AND VEGETATED IN SPRING OF 2012. 'INVERT OF DISTRIBUTION LINE = 97.65 TOP OF SAND = 97.13 15' WIDE BOTTOM OF BED EXCAVATION BOTTOM OF BED INSPECTED BY MOA (JEFF POET) = 94.13-93.52 - RELATIVE ELEVATION OF BOTTOM OF TESTHOLE = 80.13 (GROUNDWATER @ 92.13 ON 6/24/11) 'f 2-feJrffing, enc. Well Log Waren Well Dri(ring andTu"!p Set -re /%'1Cr0r4ge, %&44 007) 45-05;93. Drilling Started.04 r 21,2011 Cotnpleted: 04/2812011 Subdivision: BLOCK I LOT Property Owncr Name & Address: Wilco Contractors rite:Hyannis Cir. 16701 Ransom Ridge ,City/Borough. Anchorage The Landings 1 1 4 Anchorage, AK 99516 Meridian Township Range Section _ _ hof _ _ _ '/4of %a ort/a BOREHOLE DATA(from top of casing)Depth Drilling method: (X) Air rotary. ( ) Cubic tool, Other Material; Type, Color & wettim From To Well usc: ( ) I'ublic su 1 PP Y• (X) Uomcstic; Other __ stickup 0 2 Depth ofhole: 380 tt, Casing stickup: 2 It Casing type: sten_) _ _ 'rhickness: _250 inches Casing diameter: 6 inclics Casing depth: 55 ft overburden 2 4 Liner tvpc: FVC Diameter: 4.5 inches Depth: 20' to 380' sand $ gravel 4 20 Static water (from top of casing): 83 ft on 04 !28 /2011 Pumping level & yield: f4et atter _.. hours at .. _ gp n Recovery rate: 3 gpnt, Method of testing: airlift rocky 20 22 Development method: airlift Duration: 1 hour bedrock 22 380 Wcll intake opening type: ( ) Open end. (X ) Open hole, Other ._ Scrccucd: Start: _ - li. Stopped . - _ ft Scrcen type-. „ _ - Slot/mesh size: - Performed. Start: R, Stopped: _ ft Stan: y ft, Stopped: li . Note: .......... ­­ .................................. ------------------------------------------------- Grout type._ bentonite volume - Dcpth; from ground surface to 20 It Pump intake dept[: �.. ft Pump size:._ hp, Brand name: Was well disinfected upon completion? (X) Yes, ( ) No Method of disinfcction:CialCiUM.H ochlorite.(Chlorins)... Dri Her comment.V disclaimers-.Drilled.overSlZe..into.bedt:ock.... to set .casing-_and,-.grout,.per-muni,code....................... _....•._ Water entering well thru fractures ctures at d_e_ pths of . 120' and 300' for a total of 3 gpm. ...--- I...................................................................................................... Welldriller name: _ Johnny Company name: hefty Marling address:....hag InC 3.540 Akula Dr. .............................................................. city; Anchorage_ State: AK zip 99516 Phone number : ( 907 .) 345 - 0593 fax: 345-4700 Drillers signature: j Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Section 4700 South Biagaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.tnuni.org/onsite (907)343-7904 T " d 9t722822: 01 kttention: Property owner shall provide a well log to the SSD within 60 days of well completion. Pcrmit trumbcr: OSP101224 Date of Issue: Oct / 21 /2010 Pared Identification Number: Is well located at approved permit iucation? (X) Yes or ( )No : WO�:U HG2 *0 T T02 -2-n1 NOV-3-2011 09:29A FROM: TO:3383246 P.2 Pum Installation � � LAS ",5� b' , NAit 0;-Ga���g ABOVE GROUND DATE: L% 1 CASING (�t)4V.- T Pitless Adapter Manufacturer's Name: ) V �M j�r, 6 0 X Pitless Adapter Installer: I 1 1 v i PUMP TVPE t` o J t-=. J MAKE ��Ln � o 1j)i ,� MODE. /0 r(� SERIAL f Pmnp — - f/ Motor DROP TYPE: Ty" TY C � I 0 Sko I � � aondttten P BL P01" CAE: Tyll I G� 6 k e d— Su. I l hal, a w Condition iV ttll � '11 e l ELECTRICAL: vat. `� V AnVs I WATER TANK: �. �. HELL CASOM 51n DRL TV9 ICASED NM& Freon rr� � To {� WTAKE STRUCTUR$: Two I Fran U0, To �Dy� OPEN NOIF: From J To V 0 / �Vc. go, well was disinfected upon completion, method: calcium hypochlorite. JI ��`1-Cefty Drung, CCiInc Water Weffand Pump Service Anchorage, Alaska (907) 345-0593 On -Site Water & Wastewater System Permit Permit Number: OSP101224 Tax Code Number: 02006111000 Work Type: WellSeptic Initial Permit Effective Dates: October 21, 2010 to October 21, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: THE LANDINGS Site Legal Address: THE LANDINGS BILK 1 LT 4 G:3235 Owner/Address: ELLIS WAYNE E 5700 LAKE OTIS PARKWAY #C-56 ANCHORAGE AK 995071754 Site Mailing Address: 16045 Hyannis CIR, Anchorage Lot Size in Sq Ft: 26270 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Permit includes waiver OSP101225, allowing the well to be a minimum of 50 feet from the AWWU public sewer force main and manholes. Received Issued By J L LQ% Z Date: v Z Date: G� c� MUNICIPALITY OF ANCHORAGE. Development Services Department On -Site Water & Wastewater Program - 4700 Elmore Road, PO Box 196650�r ��z3rPT�aat Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101224 Tax Code Number: 02006111000 Work Type: WellSeptic Initial Permit Effective Dates: October 21, 2010 to October 21, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: THE LANDINGS Site Legal Address: THE LANDINGS BILK 1 LT 4 G:3235 Owner/Address: ELLIS WAYNE E 5700 LAKE OTIS PARKWAY #C-56 ANCHORAGE AK 995071754 Site Mailing Address: 16045 Hyannis CIR, Anchorage Lot Size in Sq Ft: 26270 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Permit includes waiver OSP101225, allowing the well to be a minimum of 50 feet from the AWWU public sewer force main and manholes. Received Issued By J L LQ% Z Date: v Z Date: G� c� Mul Anchorage, p C Wehorage !0 Elmore Road 7904 0 Fax (907) 343-7997 Insite :es Department _ . awater Program men r cS , 4 Department H * * * * VARIANCE/WAIVER REVIEW * * * * WR#: OSP101225 HA#: Permit#:OSP101224 PID#: 020-061-11 Legal Description: The Landings, Blk 1. Lt 4 Engineer: GEG Applicant: Wilco Contractors Your request for a waiver of the required 75 feet horizontal separation from the public sewer trunk to the private well has been approved. The approved separation distance is,5AK feet. 41-5 14 rl T(,' Your request for a waiver of the required 100 feet horizontal separation from the public sewer manhole to the private well has been approved. The approved separation distance is.5�feet. P e,1 This waiver approval applies to the existing public sewer trunk and manholes to private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ■ MEMEMNENNNNN MEN ENE MEN MOENonNoBEENE0MENNEENNEMEREEN NNEEM■NNMMNNNMNMNMNMNNMMNE■. Waiver is Granted: X Waiver is not Granted: Date: 10/21/2010 Approved by , Name of Reviewer ............................................................................... Rec#: 071420 Amount: $1,050.00 Date Paid: 9/29/2010 **** VARIAN C E/WAIVER REVIEW **** Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION Uurianc� �rj- PJD /22.5 FOR A SINGLE FAMILY DWELLING D5►��012Z. y Parcel I.D. 020-061-11 Property owner(s) WILCO CONTRACTORS Day phone 345-6288 Mailing address 16701 RANSOM RIDGE * ANCHORAGE AK * 99516 Site address 16045 HYANNIS CIRLCE * ANCHORAGE. AK Zip Code 99516 Legal description (Sub'd, Block & Lot ) THE LANDINGS S/D: BLOCK 1, LOT 4 Legal description (Township, Section & Range) N/A Lot Sizes 27b Sq.Ft. THIS APPLICATION IS FOR ( ® all that apply) Absorption Field Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Number of Bedrooms THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees:. 5 --� O -i- 0 U Waiver Fees: 1,(250 Date of Payment: 17 — —�_) 1 / L) Date of Payment: I I / c` Receipt Number: p (J 2 1 % Receipt Number: 7 (Rev. 11/05) .1 Co I GARNESS ENGINEERING GROUP, Ltd. mawmawAns CONSULTANTS & GENERAL CONTRACTORS October 19, 2010 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road, P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Septic Upgrade for The Landings S/D; Block 1, Lot 4, To whom it may concern: The proposed 3 bedroom house will be served by a private well and septic system. We are proposing to install a new 1500 gallon S.T.E.P. tank with Quanics controls and floats, and a bed type drainfield. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: The topography in the area of the proposed drainfield is relatively flat. In short, there are no slope concerns. 5. WAIVER FROM WELL TO SEWER FORCE MAIN: Due to site constraints limiting the available space to put a well on this property, we are requesting you waive the distance from the proposed well to the existing AWWU public sewer force main and manholes. We are requesting that the allowable separation distance be waived (from the required 75 feet and 100 feet) down to feet. Justification for the waivers is as follows: � Q. � r so"Q'- � • sS Attached are the AWWU records showing the location and description of the sewer force main. The main is constructed of ductile iron, pressure tested with corrosion control provisions. See attached logs from surrounding wells and past water sample results. This area is not problematic for nitrates or bacteria in the groundwater. There is a swale between the force main and the proposed well that would intercept and 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com divert any wastewater (away from the well) that might inadvertently be released via the air relief vents on the AWWU force main. Based upon the aforementioned facts, we believe there is minimal risk associated with granting this waiver. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you love any questions, please contact us at 337-6179. Thank you for your assistance. Jeffrey YrnP.. ., M.S. NOTE. Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com 00' WELL RADIUS I ( LOT 1, BLOCK 1 LOT 2, BLe(CK 1 THE LANDINGS S/D HE LANDAGS S/D , �> ` \ / LOT 3, BLOCK 1 \ / THE LANDINGS S/D PROPOSED 100' WELL RADIUS / \\ 1 100' RADIUS L T 1, BLOCK 2 \ � lb TH� LANDINGS S/D \'10 ' WELL U `� PROPOSED /4 0' W L RADIUS BUILDING / -PROPOSED SEPTIC\ \ / \ \ STEM Vn LOT 5, BLOCK 1 / THE LANDINGS S/D LOT 6, BLOCK 1 LOl/ 2, BLOCK 2 j ti ���y� / / THE LANDINGS S/D THE/ LANDINGS S/D1 0' WELL US �ti ` L I \ I 1 ELL RADI \ LOT 7, BLOCK 1 _ \ l t'• �� \ �1�,� THE LANDINGS S/D LOT 3, BLOCK 2 THE LANDINNGSS/D / 0 \ \ \ LOT 8, BLOCK 1 \THE LANDINGS S/D LOT 4, BLOCK 2 THE LANDINGS S/D \ • ' \��\ \\ SCALE: ,. • `� \ 1" = 100' •\ 0006�O�O ,q Op GARNESS ENGINEERING GROUP, Ltd. 4 :• 4-)Q�* CONSULTANTS & GENERAL CONTRACTORS • • • . • • • • ; • •'• ` • • . • • • 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-6179 • FAX (907)338-3248 WEBSITE: w gomeseengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: a.✓~ I WILCO CONTRACTORS 345-6288 1 OF 3 O ME— THE O .JefA. Gayness.LEGAL DESCRIPTION: DRAWN BY: LANDINGS BLOCK 1. LOT 4 A.J.G. TYPE OF WORK: DATE: �pppO'10 a\o SITE PLAN 10/13/2010 ipe mm�e c v) **MAXIMUM DEPTH: 2' WIDTH: 15' LENGTH: 20' M.O.A. APPROVED SAND FILTER: 3' EFFECTIVE: 0.5' REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 300 NOTE: CONTRACTOR SHALL HAVE EASEMENT FLAGGED BY A PROFESSIONAL LAND SURVEYOR PRIOR TO CONSTRUCTION **EXCAVATION WILL BE LIMITED TO TWO L FEET. THREE FEET OF SAND WILL BE TH PLACED IN THE BED, THE TOP OF SAND WILL BE ONE FOOT ABOVE O.G. ELEVATION SHOTS WILL BE TAKEN IN THE v FIELD TO ENSURE THAT THERE WILL BE A MINIMUM OF 5 FEET OF SEPARATION BETWWEN THE BOTTOM OF THE FIELD AND GROUNDWATER. REVISED / /APPROXIMATE LOCATIONIX \ / / OF NEW WELL 1 / \\`� Pa��O�-te \ MATE 7 / PROPOSE PROPOSED BUILDING PROPG�ED 650 \ AyE,�.Rfd ELL IT INTERNAL \� SANDY VALVE \ 1 \ \0 / /PROPOSED \ 0 \ � \ \r0� /\ GALLON S.T.E.P. TANK \ 0. e a\ e \ ��EDGE OF \� LOT 5, BLOCK 1 7' FROM N \ \ PAVEMENT THE LANDINGS S/D \ PER AWWU \ I \\ RECORDS SCALE: a v \\� 1" = 40, 0006�p 0 _ Op a4 p GARNES'>�° EENGINEERING�GRIa�JF Ltd. �* -� 4 ..... .........:..� o 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 ° PHONE (907)337-6179 • FAX (907)336-3246 ' WEBSITE: www.gom engineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: a . ••• • •••••. 4_ WILCO CONTRACTORS 345-6288 2 OF 3 e A. Gayness: li LEGAL DESCRIPTION: DRAWN BY: oOo 9 CE \ THE LANDINGS BLOCK 1, LOT 4 A.J.G. ap��I o0 �O000���o TYPE OF WORK: DATE: 4 DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM 6/24/11 LETTER THAT PERTAINS TO THIS DESIGN. NUMBER OF BEDROOMS: 3 TO OBTAIN A COPY OF THE LETTER GALLONS PER DAY (GPD): 450 CONTACT GEG. BY PROCEEDING FORWARD PERCOLATION RATE/S: 40 WITH THIS INSTALLATION, THE ENGINEER, PROPOSED APPLICATION RATE: *2.0 GPD/FT' WELL DRILLER, CONTRACTOR AND MINIMUM DRAINFIELD SQ.FT.: 225 PROPERTY OWNER AGREE THAT THEY *ADVANCED TREATMENT SYSTEM HAVE READ THESE SPECIFICATIONS AND AGREETO ACCEPT THE AND DRAINFIELD DESIGN: CONDITIONSOUTLINED. **MAXIMUM DEPTH: 2' WIDTH: 15' LENGTH: 20' M.O.A. APPROVED SAND FILTER: 3' EFFECTIVE: 0.5' REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 300 NOTE: CONTRACTOR SHALL HAVE EASEMENT FLAGGED BY A PROFESSIONAL LAND SURVEYOR PRIOR TO CONSTRUCTION **EXCAVATION WILL BE LIMITED TO TWO L FEET. THREE FEET OF SAND WILL BE TH PLACED IN THE BED, THE TOP OF SAND WILL BE ONE FOOT ABOVE O.G. ELEVATION SHOTS WILL BE TAKEN IN THE v FIELD TO ENSURE THAT THERE WILL BE A MINIMUM OF 5 FEET OF SEPARATION BETWWEN THE BOTTOM OF THE FIELD AND GROUNDWATER. REVISED / /APPROXIMATE LOCATIONIX \ / / OF NEW WELL 1 / \\`� Pa��O�-te \ MATE 7 / PROPOSE PROPOSED BUILDING PROPG�ED 650 \ AyE,�.Rfd ELL IT INTERNAL \� SANDY VALVE \ 1 \ \0 / /PROPOSED \ 0 \ � \ \r0� /\ GALLON S.T.E.P. TANK \ 0. e a\ e \ ��EDGE OF \� LOT 5, BLOCK 1 7' FROM N \ \ PAVEMENT THE LANDINGS S/D \ PER AWWU \ I \\ RECORDS SCALE: a v \\� 1" = 40, 0006�p 0 _ Op a4 p GARNES'>�° EENGINEERING�GRIa�JF Ltd. �* -� 4 ..... .........:..� o 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 ° PHONE (907)337-6179 • FAX (907)336-3246 ' WEBSITE: www.gom engineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: a . ••• • •••••. 4_ WILCO CONTRACTORS 345-6288 2 OF 3 e A. Gayness: li LEGAL DESCRIPTION: DRAWN BY: oOo 9 CE \ THE LANDINGS BLOCK 1, LOT 4 A.J.G. ap��I o0 �O000���o TYPE OF WORK: DATE: 4 DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM 6/24/11 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK. 99507 " PHONE: (907)337-6179 " FAX: (907)336-3246 - WEBSITE: gamessengineeris SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: THE LANDINGS S/D; BLOCK 1, LOT 4 PERFORMED FOR: WILCO CONTRACTORS DATE: 8/19/2010 DEPTH (feet) ORGANICS TEST HOLE #11 1 2 SOIL CLASSIFICATIONS ��"\ THE LALu I NDINGS S/D GW ORG 3 :::..:.:, GP ML ,– GM CL 4 G C OL N OPOSED o°a o SW MH I / 00 °,/ELL RADIUS / 5 SP CH SM �' OH �\TH#1 1� 6 SC �.` �.° // `` PROPOSED BUILDING 7 DEPTH TO GROUNDWATER DATE \`��� 8 GM DRY 8/19/2010'^LOT 5\BL®QK , 8' 9/27/2010 AIC \ v % THE LANDINGS S/a 9 FA 10 �� \ �Ey t " = loo, DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 TIME (MINUTES) READING (INCHES) 12 8/20/2010 1 2:40 – 6" – 2 3:10 30 5 1/4" 3/4" 13 3 3:10 – 6" – 4 3:40 30 5 1/4" 3/4" 14 5 3:40 – 6" – 15 6 4:10 30 5 1/4" 3/4" 16—B.O.H. 17 18 19 PERCOLATION RATE 40 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.5 FT. AND 6.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ANDREW GRAY COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS P RFOR ED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: C 2-S 0 0 0 �Zo�oxZoo O0{A DD -n� �1�0DZA r O •r1 rr m� D OD Z� fI --I 2 om Dom; mD 3 N � O 0 D3-NW(,i x(TJN� C, U mLA ZI �J00 Ln CO O AO�i a aD a a0 z •P � O Ue 0 < n z� I Zn r c 0 mN I mz v� C:N)�z O mN m Z� �m;u60-p 00 0 " I ? c Z mo �D fmTl� 25->Z1 N� (n -uv rnA I .Z70 Zmm mm X I I D� m0Z7 ro � f�m z I 0 0 (n r = T10 TI S 0 -uN ;u mI Z oN- m 41 C nZ;; C y O Om�En -r m Z m m C 0 ; r D I 0 —0 cn -u mz + ;7 c- ---j_ (n B m D n0 V)o Z m 0 mm -v m c 0 X _ -i;a Z m5 oD < < D m- 00 Z� m M 0 0 X m m � T, o Ti r m -Ti o r c 0 Z -Ti r m 0 D c K: O u Z O m u771 N Z7 N i7 Ui O ; N mD Z C ;uN � � 0 z - O Z r <C)m 0)0Z 0 C Ui Z m 0 �� z \OD m m�� z m N _ T co Z D 0m1 0 r M� < ZO Z D m 0 z r D 0 < D m Z m m r 0 -Ti m� 02 m z Og 0 0 Z � �o ox Di z r 00600 Op o� OF pp c 49 DATE: DRAWN BY: Q .•D 9/28/2010 A.J.G.`~' .;.. LEGAL DESCRIPTION: / •: ,le�.uu..,�� ,... .. , . .....�..�.. ,, oo.� ' .J ffr A.. G..... S.... THE LANDINGS S D; BLOCK 1, LOT 12 �.x[�R�:ESS ENGINEERING GROUP, Ltd. Q �� ° �195TYPE OF WORK: CONSULTANTS&GENERALCON'TFACTOFS SDESIGN OF QUANICS AER0CELL SYSTEM3701 E TUDOR ROAD SUITE 101. ANCHORAGE �• ��, �0 (R07) ,37_q,�iF : (qo,) „8 axle • WEBSRE a ww.gomeuent PREPARED FOR:4p P °\ WILCO CONTRACTORS PHONE NUMBER: PAGE: p�4p�OOoOo 907-345-6288 3 OF 3 Municipality of Anchorage _ . r On -Site Water & Wastewater Program n x (907)343-7904 9 e-- t S S"Au,-1 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I. D. 020-061-11 _ Expiration Date: 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Real Estate Agent 16045 HYANNIS CIRCLE *ANCHORAGE, SHARON SKELTON 16045 H,AKimc Day phone 552-5731 LINDA HOPP N1 PRUDENTIAL Day phone 351-5399 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single F- mily and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: individual Weil --- Individual Water Storage Community Class_ _Well Public Water System 3 TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ ❑: Community On-site ❑ Public Sewer ❑ Received by: Z�� COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee Date of Receipt Number COSA # O 5 Gs j j l tit tf Date: 3A7 / Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. /further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with at/ applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name Engineer's Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC a W MOA DSD Guidefires & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that me y fluctuate during ti -e year, and the water usage of the family being served by `Le system. These conditions e.re outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guara 1:ee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for 3 bedrooms. System #2 Apprcved for bedrooms. _D_1sapproved - - Conditional approval for bedrooms, with the following Phone 337-6179 Date 3 ( �7 /13 O_S`������ tOF (((fe��/ ` �= ON-SITE - WATER AND Ab+Gv4" --- U.^ — PROGRAN The Municipality or Anchorage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory /-,Other By: �d L (Re v. 1.... Original Certificate Date: :� -,-q / ��� If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: THE LANDINGS; BLOCK 1, LOT 4 Parcel ID: 020-061-11 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 4/28/11 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 380 ft. _Cased to 55 ft. Casing height (above ground) 24 in. Date of test Static water level FROM WELL LOG 4/28/11 ft. AT INSPECTION NEW WELL ft. Well production 3 g.p.m. 9-P M. WATER SAMPLE RESULTS: Coliform�0 colonies/100 ml. NitrateN0 mg./L. Collected by: GEG. Ltd. Arsenic:o. 10 ug./L. Date of sample: 3/19/13 B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEP/STEEL Date installed 6/24-27/11 Tank size 1500 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping Pumper NOT NEEDED PER QUANICS SERVICE PROVIDER C. ABSORPTION FIELD DATA]*BELOW EXISTING GRADE QUANICS AEROCELL SYSTEM Date installed 6/24-27/11 Soil rating (g.p.d./ftor /bdrm)2.0 System type BED Length 20 ft. Width 15 ft. Gravel below pipe 0.52 ft. Total depth *3.09+ ft. Eff. absorption area 300 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) PASS For E bedrooms Fluid depth in absorption field before test = in. Water added =gal. New depth in. Elapsed Time: — min. Final fluid depth in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date — D. LIFT STATION Date installed 6/24-27/11 Size in gallons 1500 Manhole/Access (Y/N) YES "Pump on" level at TIMER in. "Pump off' level atTIMER in. High water alarm level at 46 in. Datum BOTTOM OF TANK Cycles tested NEW Meets alar & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main *45'+ Public sewer manhole/cleanout *45'+ Sewer /septic service line 25'+ Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parkingivehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *WR#OSP101225 G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Print Y Na Te JEFFREY A. GARNESS Date 31 IN (Rev. 11/05) Municipality of Anchorage &, • '� Development Services Department °_ Building Safety Division 1 s E r On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-061-11 COSA# L"5L. 1. GENERAL INFORMATION Expiration Date: _� 1,2 t 11R Complete legal description THE LANDINGS; BLOCK 1 LOT 4 Location (site address) 16045 HYANNIS CIRCLE *ANCHORAGE AK Current Property owner(s) WILCO CONTRACTORS Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing address 16701 RANSOM RIDGE *ANCHORAGE, AK 99516 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY^ Individual Well Individual Water Storage ❑ Community. Class Well ❑ Public Water System ❑ Day phone Day phone 345-6288 TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, l verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE M Approved for bedrooms. Disapproved. Conditional approval for Attachments: COSA Checklist l� Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report NitrataAdvisory f/ Other By (Rev. 11105) Phone 337-6179 Date 11 IS7 / 0 t%11111,x'" WAtAWATER Original Certificate Date: i Municipality of Anchorage �F........ ...::::::::.::::::: Development Services Department ; a` • ; x Building Safety Division On -Site Water & Wastewater Program ' A ` ` T' 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: THE LANDINGS; BLOCK 1, LOT 4 Parcel ID: 020-061-11 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N A Date completed 4/28/1 1 Sanitary seal (Y/N) YES Total depth 380 ft. Cased to 55 ft. FROM WELL LOG Date of test 4/28/11 Static water level 83 _ft. Well production 3 g.p.m. Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 24 in. AT INSPECTION NEW WELL ft. g. p. m. WATER SAMPLE RESULTS: Coliform ® A colonies/100 ml. Nitrate �mg./L. Collected by: GEG, Ltd. Arsenic. -I. g 9 ug./L. Date of sample: Id (� B. SEPTICIHOLDING TANK DATA Tank Type/Material STEP/STEEL Date installed 6/24-27/11 Tank size. 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping NEW Pumper - C. ABSORPTION FIELD DATA *BELOW FINAL cRAOE Date installed 61 24-27/1d./ftzor m 2.0 System type BED / Soil rating (g•p• /bdr Length 20 ft. Width 15 ft. Gravel below pipe 0.52 ft. Total depth *3.09+ ft. Eff. absorption area 300 ft2 Monitoring tube YES Depression over field NO NEW Results Pass/Fail PASS For 3 bedrooms Date of adequacy test ( ) Fluid depth in absorption field before test - in. Water added - gal. New depth - in. Elapsed Time: - min. Final fluid depth - in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - D. LIFT STATION Date installed 6/24-27/11 Size in gallons 1500 Manhole/Access (Y/N) YES "Pump on" level at TIMER in. "Pump off' level at TIMER in. High water alarm level at 46 in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main *45'+ Public sewer manhole/cleanout *5V S f — Sewer /septic service line 25'+ Holding tank N/A Animal containment areas 50'+ Manuretanimal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots '100'+ F. COMMENTS *WR OSP101225 4otS�0 4 G. ENGINEER'S CERTIFICATION o I certify that/ have determined through field inspections and p * 9 T �D review of Municipal records that the above systems are in . • • • ..... Q conformance with MOA COSA guidelines in effect on this Q 11 date. Je rey . Gar ess. Q Engineer's Printed Name JEFFREY A. GARNESS QQO� CE— 0 Date 11 f 1511f 4��� Il,! ... A,�oo �e(Y'°rofess-W' G\ essi 'G\ lk 4l WE COSA Fee $ 11 EW3�)bWk c) (cO Ptpe Waiver Fee $ Date of Payment Date of Payment Receipt Number_ n 0 (,o Receipt Number (Rev. 11/05) o� In x� a I 0 m 1 G D I 0 m 1 G D r O H 2co ODX.SHa Om n -iH m V1 n •--I S m m D O O m D mc (n A 2 m co TO y C m H z :°<zm Boz � m Gl m m m z L 1 z z 2 1 mLn y u D�DLAA� w O r lD/1 v 0 H VPQ 1 z H H CS) D O m D H z a ~2 Nm-ni H V1 OLA VOAi�m O w -ID vm iN m A> w 00z N S I O Z O D 3 n z' m n m D 0 x u'ngor to tinSSH1 3 � 1 m H � C p wa,so < Z --I j Y :E O m A T my � M � � H Vi Municipality of Anchorage , On -Site Water & Wastewater Program - (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 020-061-11 Expiration Date: m 1 y 1. GENERAL INFORMATION Complete legal description THE LANDINGS; BLOCK 1, LOT 4 Location (site address) 16045 HYANNIS CIRCLE *ANCHORAGE. AK Current Property owner(s) SHARON SKELTON Day phone 552-5731 Mailing address 16045 HYANNIS CIRCLE *ANCHORAGE. AK Real Estate Agent LINDA HOPP W/ PRUDENTIAL Day phone 351-5399 2. TYPE OF DVKELLING: 0 Sim l a Family (w/wo ADU) ❑ Dup!ex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Ccai.'nunity Class Well ❑ Community On-site ❑ Punoc Water System ❑ Public Sewer ❑ Receiveo by: / < Date: COSA to be re' rased to the engineer, unless otherwise requested by the engineer. COSA Fee F$ Date of Receipt Number COSA# ._ I ( I�4 -7 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation date shown below, Iverify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation: . Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 1Z. 1/./ 12- Engineer's Z Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. ;y 6. DSD SIGNATURE System #1 Approved for 3 bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following ON-SITE WATER AND WASTEWATER PROGRAM ))))3)1111 The Municipality or Anchorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) bascxl only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory Septic System L.dvisory Arsenic Advisory Well Flow Advisory Other By: /j %�Q Original Certificate Date: (Rev. IM) If more than 1 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: THE LANDINGS; BLOCK 1, LOT 4 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 4/28/11 Sanitary seal (Y/N) YES Total depth 380 ft. Cased to 55 ft. FROM WELL LOG Parcel ID: 020-061-11 Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 24 in. AT INSPECTION Date of test 4/28/11 NEW WELL Static water level 83 Well production 3 g.p.m. 9 - p.m -WATER SAMPLE RESULTS: n �,�'/n Coliform 0A colonies/100 ml. Nitrate%mg./L. Collected by: GEG. Ltd. Arsenic :Lug./L. Date of sample: 11/16/12 B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEP/STEEL Date installed 6/24-27/11 Tank size 1500 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Date of pumping Depression over tank (Y/N) NO High water alarm (YIN) YES Pumper bar eeVtAui" rw l r C. ABSORPTION FIELD DATA *BELOW EXISTING GRADEf QUANICS AEROCELL SYSTEM Date installed 6/24-27/11 Soil rating (g.p.d./ftor /bdrm 2_0 System type BED Length 20 ft. Width 15 ft. Gravel below pipe 0.52 ft. Total depth *3.09+ ft. Eff. absorption area 300 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test = in. Water added =gal. New depth =in. Elapsed Time: = min. Final fluid depth = in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date - D. LIFT STATION Date installed 6/24-27/11 Size in gallons 1500 Manhole/Access (Y/N) YES "Pump on" level at TIMER in. "Pump of level at TIMER in. High water alarm level at 46 in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on Public sewer main 100'+ *45'+ Sewer /septic service line 25'+ On adjacent lots 100'+ Public sewer manhole/cleanout *45'+ Holding tank Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Properly line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parkingtvehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *WR#OSP101225 Moo'Y'A 6n4-�zaefn.Ez�.- G. ENGINEER'S CERTIFICATION I car* that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Printed Name JEFFREY A. GARNESS Date (Rev. 11/05) EC -12-2012 04:27 AM P.01 a( .. Around the Clock Pumpingg Anchorage Ala�aSpruce 99516 rive 907-345.9126 Unit # / Legal Description: Z (QD c> � Hoare Owners Name: Billing Address: Phone #1 Phone #2 Phone #3 Start up date: Dates of Service Timer -ON min Timer -OFF min Override -ON min Override -OFF min Pump Run Time min o High Level Count Low Level Count 1 Orfice Clogged Y/N Orfice Cleaned Y/N Phone Line Checked Tank Levels Checked Pumping__ Needed Floats Checked NMIv ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE AND TI IIS MEMORANDUM OF UNDERSTANDING made and entered into as of this Day of /Vwtryt6e! of 20A by and between ers,c herein the "OWNER," and the Municipality of Anchorage, herein the `MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (A W WTS), described /aas Or trl,.t i L 5 located at ' h t _ CL nC1 S Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an A W 4V IS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. Fhese approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an A W WTS that were included in the original design which Would allow the A W WTS to continue to perform as designed. E. Permit (Construction) An On -Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an A W WTS. upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On -Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of ($ U.00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for the life of the AWWTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AW WTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations. Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the A W WTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. 'Throughout the term of this Memorandum of Understanding, the Owner shall maintain AW WTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further. Owner agrees to comply will all applicable ordinance. laws, regulations. rules and orders for the A W WS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's A W WTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's A W WTS Operating Permit is: C. Owner acknowledges that the tine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the A W WTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certifi ;ate of On -Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for A W WTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's A W WTS. 7. Nonwaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terns and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: Purc,iasing Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: By:! -- Date: 12 — 7 STATE OP ALASKA THIRD JUDICIAL DISTRICT MUNICIPALITY: By: Title: Date: } ss. The foregoing instrument was acknowledged before me this -A day 20_�L, by •tom) � � ���_ NOTARY PUBLIC FOR ALASKA My Commission expires: ` Io lU 5 0EIIII N I Ck /0,P fd ORARy N•. �` Q s * PL)13V yl e L� • C lig c$a++••:UNE+A0i0t N� y®�',41E IOf pP`;'