HomeMy WebLinkAboutPARADISE VALLEY BLK 2 LT 25On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: SW2009034158
Tax Code Number: 02042315000
Work Type: WellSeptic Initial
Permit Effective Dates: December 06, 2010
Design Engineer:
Subdivision:
to December 06, 2011
GARNESS ENGINEERING GROUP LTD
PARADISE VALLEY
Site Legal Address: PARADISE VALLEY BLK 2 LT 25 G:3538
Owner/Address: LOWE DANIEL P 50% &
CALDEI FULVIA 50% 23009 ROSEBUD AVE CHUGIAK AK 995670000
Site Mailing Address: 18700 England CIR, Anchorage
Lot Size in Sq Ft: 86405
Total Bedrooms: 0
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
SPecial Provisions:
1. THE ENTIRE SUBSURFACE DISPOSAL FIELD AND/OR ALTERNATE IS NOT WITHIN A 30
FOOT RADIUS OF A PERCOLATION TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL
PERCOLATION TEST PRIOR TO THE CONSTRUCTION OF THE SEPTIC FIELD. PLEASE
SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS-BUILT INSPECTION REPORT. IF
THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP
PENDING ON-SITE REVIEW AND APPROVAL.
2. INSPECTION REPORT WILL NOT BE APPROVED UNTIL FILL INSTALLED AND HAS
TOPSOIL AND IS VEGETATED.
Date: / -,~Z 4/~/Ei~'
Date: ,,/' ~_~~'~'~.2
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww.muni.omlOnsite
Development Services Department
On-Site Water and Wastewater Prooram
I ~epal, tment
**** VAlANCE/WAIVER REVIEW ****
Waive~: OSP101283 Amended COSA#: ~
PID#: 020-423-15
Legal Description: Paradise Valley Block 2' Lot 25
Engineer: Garness Eneineerin.~ Groun
Permit~: SW2009034158
Applicant: Dan Lowe
Your request for a waiver of the required 100 feet horizontal separation from the absorption field
and tank to the private well has been approved. The approved separation distance is 75.0 feet. In
addition, the field may be located ~ from the property line and 32 feet from the excessive
slope. I
This waiver approval applies to the proposed absorption field and tank only. Any future upgrade
to the on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
Waiver is Granted: X
Waiver is not Granted:
Name o(Revie~r
Rec#: 014959 Amount: $850.00 Date Paid: 1211/10
Rec#. 088759 Amount: $200 Date Paid: 7122109
**** VARIANCE/WAIVER REVIEW ****
Paradise Valley Block 2 Lot 25
Parcel ID: 020-423-15
Waiver for 75 feet from field or tank to well
Amended March 24, 2011
General
1. Any overflowing sewage would be in a highly visable area and would be seen before
getting to the well head.
2 Category III Nitrogen reducing system will be used that meets ADEC secondary standards of
treatment.
3. The system has required regular maintenance inspections.
4. No shallow bedrock in neighboring wells.
ADEC Criteria
Water Table
Depth of water bearing zone in well 96 feet
Assumed bottom of field 8 feet
88 feet
Additional 26' added to depth of water in well due to different elevation.
Soil Sorption
Soil descriptions
DEC PTS Depth From Depth To Thickness Calc. Pts
Sand and Gravel 0.75 8 45 37 0.45
Boulder 0 45 49 4 0.00
Sand and Gravel 0.75 49 60 11 0.13
Clay 6 60 70 10 0.97
Points
Permeability
Soil descriptions
6.2
62 1.55 1.6
DEC PTS Depth From Depth To Thickness Calc. Pts
0.60
0.00
0.18
0.00
0.00
0.77
Sand and Gravel 1 8 45 37
Boulder 0 45 49 4
Sand and Gravel 1 49 60 11
Clay 0 60 70 10
0
Water Table Gradient -
Water table has no slope
Assume minimum +0% slope
62
Horizontal Separation
75 feet between septic tank/field and well
x=2.0
0.8
2.9
Total Points 13.5
As per ADEC waiver guidelines, with a minimum point value of 13.5, no bacterial polution possible but
chemical pollution possible but unlikely from household chemicals.
GARNESS ENGINEERING GROUE Ltd.
CONSULTANTS & GENERAL CONTRACTORS ,
March 17, 2011
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Request for Well Waiver Amendment for Paradise Valley, Block 2, Lot 25,
To Deb Wockenfuss:
The referenced lot has many challenges and constraints due to the topography. The area we proposed to have
the well drilled was found to be virtually impossible to drill at. The owner of the property is doing everything
reasonable within his power to drill as far away from the proposed septic location as possible. This includes,
moving material around and constructing a retaining wall that would allow the drill rig to get further back of
the property. We are requesting you amend the well waiver already approved for 75 feet fi'om the proposed
well to the proposed drainfield reserve site area to 75 feet to include the proposed drainfield reserve site area
and the proposed primary drainfield and STEP tank. The following are mitigating factors for the justification
of the waiver:
We are proposing to use a MOA category III Nitrogen reducing Quanics Aerocell unit that will
produce an effluent meeting State of Alaska DEC secondary standards.
The system is an advanced treatment system which requires regular maintenance inspections. The
downhill slope will be inspected during each site visit.
Attached are two surrounding well logs. The well logs indicate that there is no shallow bedrock and
the soil strata consist of sand, gravel, & clays.
We were able to locate one water sample pulled in 1991 for Paradise Valley Block 2, Lot 27 and its
nitrates level was 1 o3 mg/Lo
A 75 foot waiver was already granted from the proposed well to the proposed drainfield reserve site
area.
I believe there is minimal risk associated with the grating of this waiver. See attached cross section drawing.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If
you have any q~act us at 337-6179. Thank you for your assistance.
Jeff,.~ / Oi~itness~, M.S.
Presiden
3701 E. Tudor Road, Suite 101 * Anchorage, AK 9950%1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw St.
P.O. Box 196650
Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERHIT APPLICATION
FOR A SINGLE FAHILY DWELLING
Property owner(s) Don Lowe
Day phone 350-9856
Mailing address 23009 Rosebud Rood Avenue *Chugiok, AK 99567
Site address 18700 Enqlond Circle
Zip Code
Legal description (Sub'd, Block & Lot ) Porodise Volley B2 L25
Legal description (Township, Section & Range)
Lot Size ~'~ ~'i~ ~' Sq. Ft.
Number of Bedrooms
THIS APPLICATION IS FOR ( [] all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
Permit/Rush Fees:
Date of Payment: ~
Receipt Number:
(~.~. ~ ~/o~)
Waiver Fees: ~:~ 0 rO
Date of Payment: '-7/ ~)..,~/0 0.~
Receipt Number:
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
November 299 2010
REVISED 12/2/2010
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Revised Design: Well & Septic System for Paradise Valley, Block 2, Lot 25,
To Deb Wockenfuss:
We have previously submitted a design package for the referenced property and a permit has not been issued to
date. The owner has requested that we revise the design for the following reasons;
· The owner of the referenced property has recently re-graded his lot pushing the cutbank back.
· The house and its location have been re-platted.
· It was requested that we re-locate the proposed well location. The home owner informed us that he had met
with you and you advised him that because of the challenges he faces with steep slopes that he could apply
for a 75' waiver from the proposed well to the proposed septic system and/or proposed reserve site, so that
he could place his well in a more reasonable location°
The proposed 4 bedroom house is to be served by a private well and septic system. The topography of the lot
dictates that the new drainfield be installed on the south end of the property. We are proposing to install a
1500 gallon SoT.E.P. tank with Quanics control/floats, a 650 Aerocell unit, and a bed type drainfieldo Two test
holes were excavated on the property. The drainfield will be designed around the 30 foot radius of test hole
#1. Depending on the elevation of the plumbing from the house, a pump vault may be necessary to transfer
wastewater from the house to the STEP tank. Comments regarding the design are summarized as follows:
1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring, and the
percolation test results°
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system.
4. TOPOGRAPHY AND WAIVER REQUEST: As can be seen on the attached design drawing, the
average topography below the drainfield is a 60+ percent slope, running approximately south to north. The
proposed drainfield is currently residing 32' away from the top of the cutbank. We are requesting a 32' waiver
be granted from the drainfield to the cutbank. As can be seen on the attached drawing, at a 25% slope (starting
2 feet above the invert of the drainfield) the potential point of daylighting is greater than 50' horizontally from
the bed. The following are mitigating factors for the justification of these waivers:
· We are proposing to use a MOA category III Nitrogen reducing Quanics Aerocell unit that will
produce an effluent meeting State of Alaska DEC secondary standards in regards to BODS/TSS.
Consequently, if effluent were to daylight, there is less potential for environmental impact~
· The system is an advanced treatment system which requires regular maintenance inspections. The
downhill slope will be inspected during each site visit.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
· Given the porosity of the soil, there should be rapid downward migration and minimal lateral
migration of the effluent.
· The fill will be topsoiled and seeded to prevent erosion and inhibit surface daylightingo
· The slope is in a prominent location; therefore daylighting effluent will be immediately noted.
In short there is minimal risk associated with the grating of this waiver. See attached cross section drawing.
5. LOT LINE WAIVER REQUEST: We are requesting a 5 foot lot line waiver from both the proposed
drainfield to the south lot line and the reserve drainfield from the south & west lot lines°. Due to the limited
space and steep topography, placing the beds in the specified locations is the only viable optionsa The
following are mitigating factors for the justification of the waiver:
· We are proposing to use a MOA category III Nitrogen reducing Quanics Aerocell unit that will
produce an effluent meeting State of Alaska DEC secondary standards in regards to BODS/TSSo
Consequently, if effluent were to daylight, there is less potential for environmental impact°
· The system is an advanced treatment system which requires regular maintenance inspections. The
downhill slope will be inspected during each site visit.
· Given the porosity of the soil, there should be rapid downward migration and minimal lateral
migration of the effluent.
· There are no existing septic systems within 50 feet of the proposed drainfield or reserve site.
6. 75' WELL WAIVER REQUEST TO RESERVE SITE: Due to site constraints and the difficulties of
accessing areas where the well can meet the separation of both the proposed septic system and the reserve
drainfield site, we are requesting a 75' waiver be granted from the proposed well to the proposed reserve
drainfield site area. The following are mitigating factors for the justification of the waiver:
· We are proposing to use a MOA category III Nitrogen reducing Quanics Aerocell unit that will
produce an effluent meeting State of Alaska DEC secondary standards in regards to BODS/TSS
nitrate levels averaging less than 30 mg/L and fecal coliform levels averaging less than 20,000
Col/100 mL.
· The system is an advanced treatment system which requires regular maintenance inspections. The
downhill slope will be inspected during each site visit.
· Attached are two surrounding well logs. The well logs indicate that there is no shallow bedrock and
the soil strata consist of sand, gravel, & clays.
· We were able to locate one water sample pulled in 1991 for Paradise Valley Block 2, Lot 27 and its
nitrates level was 1~3 m~L.
In short there is minimal risk associated with the grating of this waiver. See attached cross section drawing.
~y adverse impacts this installation would have on adjacent wells or septic systems.
;, please contact us at 337-6179. Thank you for your assistance.
If
NOTE: Attached is a site plan drawing, a design drawing, two soil logs, which are all part of the design
package for this septic system (Contact G.E.G. Ltd. for 7page construction specification letter.)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.garnessengineering.com
-'"'"'"'"'~REVISED 11/29/2010~_____~
~,R,, ~B~IV, S,ON
PARADISE VALL~ SUBDIVISION / / ~% ~' ~ ~
LOT 24, BLOCK 2, ~ ~ ~ ~~~PROPOSED
~ ~ PA~DISE VALL~ ~ ~--~ARADISE VALL~ PA~DISE VALL~ j I
j.j ~ ~ LOT ~, BLOCK 2, J ~ LOT 28 BLOCK 2 LOT 29 BLOCK 2
~l N ~ k z .... I I
,-=,oo, ENGLAN~ h VENUE
......
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ~ ~ -~
DAN LOWE 440-5~55 1 OF 5 ~(;~
LEGAL DESCRIPTION: ' I DRAWN BY: kVO~
PARADISE VALLEY SUBDIVISION, LOT 25, BLOCK 2 PNB ~
SITE P~N , 1'1/29/2010
(Rev. 01/05)
CO
DESIGN CRITERIA:
NUMBER OF BEDROOMS: 4-
GALLONS PER DAY (GPD): 600 7/5/2
.ERCO~,,o. R*,EZS: <, .,N.Z,.~. R EVI S E D 0 1 1
PROPOSED APPLICATION RATE: 5.0
MINIMUM DRAINFIELD SQ.FT.: 120
DRAINFIELD DESIGN:
MAXIMUM DEPTH: 6 FEET
WIDTH: 8 FEET
LENGTH: 15 FEET
M.O.A. APPROVED SAND FILTER: 2 FEET
EFFECTIVE: 0.50 FEET
REDUCTION FACTOR: N/A
ACTUAL SQ.FT.: 120
GEG. Ltd. HAS A 7 PAGE SPECIFICATION ~. TR
LETTER THAT PERTAINS TO THIS DESIGN.
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION. THE ENGINEER.
WELL DRILLER. CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND ~ .-~' -'~ ~"
CONDITIONS OUTLINED. ~- ~ ~[ 'X,~Ox
NOTE: THE CONTRACTOR\
SHALL HAVE THE SOUTH LOT \_ .---~ -~. ~
LINE, NEARBY EASEMENTS. J ~ ~'~ ~ ~ ~,~ ~
FLAGGED BY A REGISTERED /" \.. ~ ~"~ \
LAND SURVEYOR PRIOR TO \~ / X \
CONSTRUCTION. \-~ ~/ X
PROPERTY MAY NEED AN ~r ,~7 - \
ADDITIONAL PUMP VAULT ~ \~ ~7 x_ -F(tO -
BETWEEN THE HOUSE AND ~ \~ .~/~ \ ~ / 1 .........
THE HOUSE. ~ \ ,~+~ / L ~t~ ~', CONTROLS
LOT 4 K iu~ ur h "~-
2 , BLOC 2, - J
N ~ ~ ~ ALTERNATE
PREPARED FOR: I PHONE NUMBER: m PAGE NUMBER: ~_~"
PARADISE VALLEY, BLOCK 2, LOT 25 J.L.M. X~;:.;
.PI OF WORK: DATE: REVISED
SEPTIC DESIGN 7/5/2011
FLAT
~
SCALE: 1 "= 5'
GARNESSc~.~N,?,.IT~ERING GROUP. Ltd
: ~l~-~.:',,~../I. lt.~ ..~
LEGAL DESCRIPTION:' D~WN BY:
PARADSE VALLEY, BLOCK 2, LOT 25 PNB
~PE OF WORK: DATE: ~rOfesS~o~/
SLOPE WAIVER 11/29/2010
Z
-0o
--<'7
~..-I
i"q rtl
--I
'7
m ~
0 --
0
0
0
0
· wi
I
0 C
C
-O
7
r--
7'
m
r~
O<
7
mo 7
-t7
0 m
T
~.Dm
713
'13
;:0
ITl
(./3
C (,/3
'-n
frl r'-
DATEi DRAWN BY:
11/29/2010 J.L.M.
LEGAL DESCRIPTION:
PARADISE VALLEY; BLOCK 2, LOT 25
'PfPE OF WORK:
DESIGN OF QUANICS AEROCELL SYSTEM
PREPARED FOR:
DAN LOWE
Z
~ 0
0 C
Z -~
0
C
m
I 'RNESS ENGIN E ::iNG OROUP, Ltd.
GrA ?
CONSULTANTS & GENERAL COMTI~ACrOES
440-3333 OF ~
GARNESS.EN'G INEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
,3701 E. TUDOR ROAD, SUiTE 101 * ANCHORAGE, AK. 99507 * PHONE: (907)557-6179 * FAX: (907)338-3246 * WEBSITE: gamessengineering.com
ISOIk LOG - PERCOLATION TESTI
LEGAL DESCRIPTION: PARADISE VALLEY SUBDIVISION, LOT 25, BLOCK 2,
PERFORMED FOR: CHRIS CHIEI · DATE: 3/8/2007
ORGANIC
LOAM
SOILS LOGGED BY:
TEST HOLE #2I
SOIL CLASSIFICATIONS
GW ~ ORG
GP PIL
GPI CL
GC GL
SW MH
SP CH
SP1 OH
SC
GP TO SP
MORE SAND
SOME SILT
w/DEPTH
DEPTH TO DATE
GROUNDWATER
DRY 3/8/2007
DRY 3/15/2007
osE,,
-+ TH~1F- -I ~- '
SCALE,:
DATE READING CLOCK NET TildE WATER LEVEL NET DROP
TildE (MINUTES) READING (INCHES)
PERCOLATION RATE - (MIN./INCH) PERC. HOLE DIA. -
TEST RUN BETWEEN - FT. AND - FT.
A FOUR HOUR PRESOAK WAS PERFORHED: [] YES []NO
JODY MAUS PERCOLATION TEST PERFORMED BY: -
(INCHES)
CONFIENTS:
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS /DERF, ORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
(;ARNIZSS IZN-(;INEERIN'G OROUP, Ltd
ORGANIC TEST HOLE ffl
5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK. 99507 * PHONE: (907)3;~7-6179 * FAX: (907)~,58-3246 * WEBSITE: garnessengineering.co
s~-O-FL--L-OI~ - ~ - P E---~--6[ ~ ~]-0-~- ~ ~ i
LEGAL DESCRIPTION' PARADISE VALLEY SUBDIVISION, LOT 25, BLOCK 2,
LOAM
GP TO SP
MORE SAND
SOME SILT
w/DEPTH
SOIL CLASSIFICATIONS
GW ~ ORG
GP I'dL
GM · CL
GC OL
SW MH
SP CH
SM OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 3/8/2007
DRY 3/15/2007
+ THO'1 F'
~ ~ TH#2 i,
SCALE,:
1" = 107
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
3/9/2007 1 12:20 - 6- _
2 12:21 1 - 6"
5 12:21 - 6,, _
4 12:22 1 - 6"
5 12:22 - 6- _
6 12:25 1 - 6"
7 12:23 - 6- _
8 12:24 1 - 6"
PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES
SOILS LOGGED BY:
COMMENTS:
TEST RUN BETWEEN 5.5 FT. AND 4.5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES
JODY MAUS PERCOLATION TEST PERFORMED BY:
[~NO
KYLE MAUS
PERFORMED BY GEG, Ltd. 1, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS, PEBFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: