HomeMy WebLinkAboutDRAKE BLK 4 LT 7I r=ke
lock 4
Lot 7
017-462
-03
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-~904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Date Issued: Nov 04, 2009
Expiration Date: Nov 04, 2010
Permit Number: SW090229
Legal Description: DRAKE BLOCK 4 LOT 7
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: CHRIS KENDRICKS
Owner Address: 12421 SILVER SPRINGS
ANCHORAGE, AK 99516-
Parcel ID: 017-462-03
Site Address: 2701 FLYWAY AVENUE
Lot Size: 99307 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank
Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
1. 100' RADIUS OF THE NEIGHBORING WELLS ARE TO BE SURVEYED AND STAKED. IF THE RESULTS
REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW
AND APPROVAL.
2. THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN A 30 FOOT RADIUS OF A PERCOLATION
TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST DURING THE CONSTRUCTION
OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS-BUILT
INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM
WILL STOP PENDING ON-SITE REVIEW AND APPROVAL.
Received By:
Issued By:
Date:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, Alaska 99507
www. muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Property owner(s) (ll/..:iA~:):~, 4~h phone
Mailing address /~'( '~ ' ~" ' ' ;: "~'' ~
~ / ~,~.'~U.~ ./~Z')',:'~'Z~ Zip Code
Legal description (Sub'd., Block & Lot) ~ d Z'~ ~,,. ~ [~
Legal description (Township, Range & Section)
,o, siz 7 ,t.
Number of Bedrooms
THIS APPLICATION IS FOR ([~ all that apply).;
Absorption Field E~~'
septic Tank E~'/
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
t certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owr/er or authored agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Date Issued: Oct 30, 2007
Expiration Date: Oct 29, 2008
Permit Number: SW070298
Legal Description: DRAKE BLOCK 4 LOT 7
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: CHRIS KENDRICKS
Owner Address: 12421 SILVER SPRINGS
ANCHORAGE, AK 99516-
Parcel ID: 017-462-03
Site Address: 2701 FLYWAY AVENUE
Lot Size: 99307 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank
[] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
1. 100' RADIUS OF THE NEIGHBORING WELLS ARE TO BE SURVEYED AND STAKED. IF THE RESULTS
REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW
AND APPROVAL.
2. THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN A 30 FOOT RADIUS OF A PERCOLATION
TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST DURING THE CONSTRUCTION
OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS-BUILT
INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM
WILL STOP PENDING ON-SITE REVIEW AND APPROVAL.
Received By: ./~. '(~-
Issued By:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www. muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. ~ i,~L, q(_¢,
Property owner(s) _(/_ x~.~ J? / .% '"/--)4~'~E:~'..~.,.C,~-d~,~ Day phone
Mailing address /~/ ~.~/% ~v~:~ ~ ~/~ Zip Code
.
Legal description (Sub'd., Block & ~) - /~~ ~ ~ L ~
Legal description (Township, Range & Section)
Lot Size ~'~.?~ Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR ([~ all that apply): THIS APPLICATION IS AN:
Absorption Field [] Initial
Septic Tank [] Upgrade
Holding Tank [] Renewal
Privy []
Private Well []
Water Storages_. []
I certify that t/be information is correct. I further certify that this application is being made for a
Single Fa/~//~elling and is in .accordance with applicable Municipal Codes.
(Si~ature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev, 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Date Issued: Sap 19, 2006
Expiration Date: Sap 19, 2007
Permit Number: SW060305
Legal Description: DRAKE BLOCK 4 LOT 7
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: RACHEL S. SCOTT
Owner Address: PO BOX 111073
ANCHORAGE, AK 99511-
Parcel ID: 017-462-03
Site Address: 2701 FLYWAY AVENUE
Lot Size: 99307 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank
[] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
1. 100' RADIUS OF THE NEIGHBORING WELLS ARE TO BE SURVEYED AND STAKED. IF THE RESULTS
REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW
AND APPROVAL.
2. THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN A 30 FOOT RADIUS OF A PERCOLATION
TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST DURING THE CONSTRUCTION
OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS-BUILT
INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM
WILL STOP PENDING ON-SITE REVIEW AND APPROVAL.
Issued By: /~,.,¢/~ ('/(/)(77 ~¢~ ;~?/f.c"L,.~
Date:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-462-03
Property owner(s) Rached S. Scott
Mailing address P.O. Box 111073 Anchorage, AK 99511
Site address 2701 Flyway Avenue Anchorage, AK 99516
Day phone 250-1850
.Zip Code
.Zip Code
Legal description (Sub'd., Block & Lot) Lot 7, Block 4, Drake Subdivision
Legal description (Township, Range & Section)
Lot Size ~C~ Sq. Ft. Number of Bedrooms
Four (4)
THIS APPLICATION IS FOR ([~ all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Si§nature of property owner or authorized aflent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
MEMORANDUM
DATE:
November 4, 2009
TO:
Deb Wockenfuss
FROM:
Mike Anderson, P.E.
SUBJECT:
Lot 7, Block 4, Drake Subdivision
Septic System Permit
The proposed design for the septic system on Lot 7, Block 4, Drake Subdivision has not
been affected by development in the area since it was originally issued. All conditions
pertaining to the original design and permit remain in effect today.
The subsurface soil conditions on the lot indicate a slow percolation rate. The original
design and approved permit allowed a 24' wide absorption bed. The width was
expanded from 15' to 24' to minimize the length required and to 'allow the entire bed to
remain within the 30' radius of the test hole. Since the bed is pressurized and an
Advantex Treatment System is being installed the width of the bed is appropriate for
this application.
The new owner of the property has executed a maintenance agreement and the original
Wetlands Permit for the lot has been extended. We therefore recommend the septic
system construction permit be renewed.
MEMORANDUM
DATE:
September 19, 2006
TO:
Deb Wockenfuss
FROM:
Mike Anderson, P.E.
SUBJECT:
Lot 7, Block 4, Drake Subdivision
Well and Septic System Construction Permit
We attempted to locate the wells adjacent to Lot 7 as accurately as possible and have
added a note to the Site Plan stating the wells must be located along with their
respective 100' protective radii prior to construction of the new septic system. In
addition, the absorption beds can be moved 10' to the east and not conflict with the
proposed driveway on the lot. If the well locations are found to conflict to the point
requiring a design change, construction of the system will stop pending On Site review
and approval. Additional percolation testing will also be accomplished during
construction of the septic system. Again, if the results require a design change,
construction of the system will stop pending On Site review and approval.
MEMORANDUM
DATE:
September 8, 2006
TO:
Deb Wockenfuss
FROM:
Mike Anderson, P.E.
SUBJECT:
Lot 7, Block 4, Drake Subdivision
Well and Septic System Construction Permit
Attached is a revised Site Plan for the subject lot. We have changed the orientation of
the lots to the west and added wells on each lot. The well on Lot 8B was constructed
this summer. No permit could be found to provide further information. The absorption
beds have been moved to be outside the protective radii for these wells.
A wetlands permit has been procured for the lot and is provided for your use. In
addition an Advanced Wastewater Treatment System Maintenance and Repair
Agreement has also been signed and is attached.
Groundwater levels have remained stable since our monitoring in July. An Advantex
Treatment System has been designed for the lot which can be placed within 2' of the
groundwater level if necessary. Based on our observations we are confident the bottom
of the absorption bed will not encroach closer than 2' to the groundwater.
April 18, 2006
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 7, Block 4, Drake Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 7 Block 4, Drake Subdivision intends to construct a four-bedroom
home on the lot. We are therefore requesting a permit be issued for a septic system to
serve the new home. The soil conditions on the lot are marginal with percolation rates
varying up to 120 minutes per inch. We have therefore decided to place an Advantex
Treatment System on the lot to provide the most effective treatment of the septic
effluent prior to discharge into the surrounding soil strata. The location of the
absorption system is shown on the attached Site Plan. Drainage patterns are also
shown on the plan and will not be modified as a result of the proposed construction.
The test holes placed on this lot revealed peat and fill material to depths of 4' to 6'
underlain by silty sand and gravel. The percolation rate in the materials encountered
was less than 1 minute per inch in the SP strata of Test Hole No. I to 120 minutes per
inch in the silt strata of Test Hole No. 2. Groundwater was found during the excavation
at 8' below the surface and has risen slightly during monitoring. We have chosen to
construct the absorption bed in the silty material near Test Hole No. 2 where the
groundwater elevations have stabilized at lower levels. We are therefore proposing to
place a four-bedroom Advantex Treatment System. The absorption bed will be 50' long
x 24' wide. The distribution line in the trenches will be placed at 1.5' below the existing
ground level. Approximately 2' of coarse sand will be required to replace the peat and
fill material and to raise the bed to at least 4' above the groundwater. A minimum of 3'
of fill will be placed over the bed and 4' over the septic tank to meet Municipal Code
and prevent freezing.
The grOund surface of the lot is basically flat near the location of the primary absorption
bed with only a slight slope to the east. The bed will be constructed parallel with the
slope as much as possible in conformance with Municipal requirements. All
Lot 7, Block 4, Drake
April '18, 2006
Page Two
components of the new septic system will be constructed a minimum of 100' from the
well proposed for the lot and any surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
o
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
MERGANSER
~69.50 330,00 330,00
i 1 2 3
103 U'~ll Esm~
....... 8_~_9,_3~_
_o. --.._~... ~ -'~"~--'- 6
~/. LLU / ~.m~>:~ ~ \
~3 330.00 330.00
/~~
/
55.00 ~ ~ ~ 150.00 ~ 50.00 150.00
I
I A~U WATER AND S~ER SE~ICE
I
8 9 j 24 25 42
I
I
I
I
5' - ..... ;,, ........... ' '
~ OF ~/'~.
~g~ MICHAEL E, ANDERSON
~.~n~ No, CE-4381
AREA HAP '~" '~'
~6'OOE
~'OOg
m
LOT 7, BLOCK 4, DRAKE
SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
4 Bedroom Home Shallow Bed System
Perc. Rate: 120 Min./Inch 4 Bedroom Advantex Treatment System
Application Rate: .5 GPD/SF 500 Gallon Add On Lift Station
4 Bedrooms X 150 GPD/.5 GPD/SF -- 1,200 SF Absorption Area
1,200 SF/24 LF (Width) -- 50 LF Bed Length
THEREFORE: Construct a Shallow Bed 50' Long x 24' Wide as Shown Below.
Place Distribution Piping at 1.5' Below the Ground Surface. Remove Organics and Place
Coarse Sand to Provide 4' Separation From Groundwater. Place Insulation
and 2' of Cover Over Bed or Mound Over Bed Minimum of 3'. Place 4' of Fill Over Tank.
Existing Ground
As Required
Top 6" of Mound Must Be Topsoiled
and Vegetated to Prevent Erosion.
Natural Backfill
2" Insulation & 2' Cover (Min.)
/ / / / / / / / /
0 0 0 0
Drainfield Rock ~ .
Coarse Sand (See Specification)
As Required for Levelling
And Replacement of Fill and Organics.
1" PVC
3/16" Holes
10 Each Lateral
Existing Ground
In Situ ML Soil
3' 6' 6' 6' 3'
NOTE:
TYPICAL BED SECTION
(NO SCALE)
Grade Area Surrounding Bed to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
Minimum 10' Separation From Water Service Line.
Z
ADVANTEXsEPTiC SYSTEMAX'20 ~~--~ANCHORAGE TANK & WELDING, INC.
~ ~~ 2700 PORCUPINE DRIVE ~ ~
S.TANDARD ,~,~ ANCHORAGE, ALASKA L,~I J'
Performed For:
Legal Description:
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20-
LOT 7, BLK 4
COMMENTS
Municipality of Anchorage
Development Services. Department
Building Safety Division
On-Site Water and Wastewater Prog{am
4700 South Bragaw St.
P.O. Box 198650 Anchorage, AK 9951.9-6650
www. ci.anchoraae.ak.us
(907) 343-7904
Soils Log - Percolation Test
DRAKE, ' ~.-/'~1::>,
Slope
Bate Performed:
Township, Range, Section:
Site Plan
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT DEPTH? L.,.
Depth to Water. After O
P
Monitoring? '~"~ "~"~ E
Reading .' Date Gress Time Net Time Depth to Water Net Drop
PERCOLATION RATE ,~ ~.. (minutes/inch) PERC HOLE DIAMETER
TEST R'UN BETWEEN 6'~' FT' 'AND '""7' ¢ FT
PERFORMED IN ACCORDANCE WITH ALl'STATE AND MuNIcIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Performed For:
Legal Description:
9-
12-
15-
20-
Municipality of Anchorage
Development Services, Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 9951.9-6650
www.ci.anchoraae.ak us
(907) 343-7904
Soils Log- Percolation Test
LOT 7, BLK 4 DRAKE
,Slope
Date Performed:
Township, Range, Section:
Site Plan
WAS GROUND WATER
ENCOUNTERED?
S
YES, AT WHAT DEPTH? ~(//,,~. :. · L
IF
O
Depth to Water. After ' I 'p
Reading .' Date Gross Time Net Time Depth tb Water Net Drop
~ES~U~ETWEE~ ~,~ FT' 'A~O ~,0 ~T
COMMENTS
pERFORMED BY: ..,~. ~-t""~ ~ ' '~~-~' (~-~ERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ ,,-/~ '¢~
OPINION OF COMPLIANCE
ANCHORAGE GENERAL PERMIT 93-1 ON
File Number: POA-2006-1416
Municipal Reference Number: Furrow Creek 06-A
Permitee: Chris Kendrick
Expiration Date: November 2, 2011 (time extension)
The permitee will perform work in waters of the U.S. (wetlands) in accordance with the terms and conditions
of the Anchorage General Permit, as specified below:
Project Location: 2701 Flyway Ave, Anchorage, AK. Lot 7, Block 4, Drake Subdivision.
Map #: 94 Wetland Unit#: 77
Work Description: Construction of s.f. home, with driveway, well and septic system.
Wetlands fill amounts: 800 Cubic Yards, 0.13 Acres
All work will be performed in accordance with the attached plan, sheets 1-4 of 4, dated
August 14, 2006; updated 8131106. Current As-Built attached (updated Nov, 2009).
Anchorage General Permit Conditions:
General conditions:
Water Quality Certification. You must comply with all conditions specified as part of the Alaska
Department of Environmental Conservation Water Quality Certification, which is part of these
General Permits (GPs).
Historic and Archaeological Sites. These GPs do not authorize activities, including the use of
material borrow sites, in or that adversely affect known historic properties listed or potentially
eligible for the National Register of Historic Places, nor any such sites listed or found to be
potentially eligible in the future. The permittee shall stop work when cultural resources are
inadvertently discovered during the course of work and notify the Corps. The Corps will enter into
consultation with the Alaska State Historic Preservation Office to determine if historic properties will
be affected by the permitted work. Work shall resume after cultural resources have been evaluated
pursuant to Section 106 of the National Historic Preservation Act.
Inspections. You must permit the District Engineer, or his designated representatives, to inspect
the authorized activity at any time deemed necessary to ensure that it is being, or has been
accomplished in accordance with the terms and conditions of these GPs.
Maintenance. You must maintain the authorized activity in good state, and in conformance with
the terms and conditions of these GPs. You are not relieved of this requirement even if you
abandon the authorized activity, although you may make a good faith or legal transfer to a third
party, as described below. Should you wish to cease to maintain the activity or abandon it without
a good faith transfer, you must obtain a modification of the GP authorization from the Corps
Regulatory Branch either directly, or through Municipal Planning Staff. Such modification may
require restoration of the area.
Sale or Transfer of Property. If you sell or transfer the property associated with the authorized
activity, you must obtain the signature of the new property owner as the transferee in the space
provided on this document and submit a copy of that page to the Municipal Planning Department
and/or Corps Regulatory Branch, along with appropriate documentation of the transaction. You
Chris Kendrick
POA-2006-1416
Furrow Creek 06-A; time extension
must submit this information within 30 days of the property transfer, to validate transfer of the GP
authorization to the new party.
Project site restrictions and design criteria:
Construction Timing Window. To protect nesting migratory birds, as required by the Migratory
Bird Treaty Act, no work (i.e., clearing, grading, excavation, stockpiling, or placing of fill) may occur
on the site between April 15 and July 15, unless: a) the site is sufficiently disturbed prior to April 15
to eliminate suitable nesting habitat; and, b) construction activity will occur continuously through
June 15.
Note: Clearing or other disturbance of the site prior to April 15 may require Corps or other
authorization.
Local Flooding. The project shall incorporate design and construction features/methods
necessary to ensure that the proposed project will not cause flooding of adjacent properties or
public infrastructure.
Stormwater Functions. The applicant shall demonstrate that the project plans include sufficient
measures to effectively replace the site's pre-project stormwater retention and filtration capacity.
The measures shall be sufficient to approximate zero net runoff increase for storms with 2-year
frequency and no more than two times net runoff increase for storms with a 10-year frequency,
including flows from subdrains. Verification that the project's stormwater design meets this criterion
must be obtained from the Municipal Wetland Management Section or its designee, and must be
included with the GP application package.
Project-specific conditions:
Time Limit. GP authorization of this project expires on: November 2, 2011. If you need
more time to complete the authorized activity, submit a request for extension under these GPs to
the Municipal Planning Department prior to the expiration date. You may not continue work beyond
the expiration date until receiving notification to that effect from the Municipal Planning Department
or the Corps Regulatory Branch.
Note: Permitee should aflow at least one month for processing of extension requests.
Other Approvals Required Before Starting Work. You must not disturb wetlands for this project
until you have obtained all applicable Municipal and State approvals required for the work. These
approvals include, but are not limited to:
Municipality of Anchoraqe:
[] Land Use Permit
[] Grading & Fill Permit
[] Building Permit
[] Right-of-Way Permit
[] Flood Hazard Permit
[] Utility Agreement(s)
[] Rezoning Approval
[] Preliminary Plat Approval
[] Subdivision Agreement
[] Stormwater Treatment Plan
[] Parks Right-of-Entry Permit
[] Wastewater Disposal
[] Urban Design Commission
[] Geotechnical Commission
Alaska Department of Environmental Conservation:
[] Stormwater Treatment Plan
[] Wastewater Disposal
[] Soil Remediation Plan
Chris Kendrick
POA-2006-1416
Furrow Creek 06-A; time extension
If any of these---or other--approvals result in a change to the attached plans, you must provide a
description of the change and a revised plan(s) to either Municipal Planning Department Staff or
the Corps Regulatory Branch, and may not proceed with the project until the change is authorized.
4. Offset Unavoidable Impacts. To offset the unavoidable adverse impacts of the project to the
aquatic environment, the permittee:
[] shall provide an In-Lieu Fee in the amount of ($6,939 x acrea,qe =) $ prior to disturbing
wetlands for this project. You may either submit this fee directly to the Great Land Trust or other
nonprofit conservation group with whom the Corps has a Memorandum of Agreement or request
that Municipal Planning Department Staff forward it to them. In either case, the fee transmittal shall
include both the GP reference number for the project and the extent of wetlands impact (square
feet or acres) it is intended to offset.
[] Excluding lots located in new subdivision developments, single family homes impacting less
than 16,500 square feet of wetlands are exempt from this requirement.
[] shall sign a Tolling Agreement with the Corps of Engineers, Regulatory Branch
Limits on Work Area. You must not conduct any of the following activities in wetlands or
waterbodies beyond the approved project footprint (or in any other avoidance area identified above)
during either construction or operation of the project/facility:
Discharge of fill material (even temporarily), including stockpiles; or,
Excavation and sidecasting/backfilling; or,
Mechanized landclearing; or,
Operation, parking/storage or servicing of equipment.
Construction Runoff. You must employ runoff control measures necessary to preclude or
minimize both erosion and the transport of sediment, pollutants, and solid waste beyond the
approved project footprint. These measures shall include, but are not limited to:
Phasing of Site Preparation (to minimize the extent of exposed soil);
Silt Fence;
Reroute Offsite Runoff around Disturbed Soils (e.g., dike/ditch)
Mulching (e.g., wood chips, straw, grass clippings, gravel);
Matting (e.g., jute, straw, coir);
Sheeting for Stockpiles, Temporarily Exposed Slopes (e.g., plastic, geotextile fabric);
Check Dams in Ditches/Drainageways (e.g., hay bales, sand bags, gravel berms);
Surface Roughening (to slow runoff down slope);
Terracing of Slopes;
Sediment Trap(s);
Temporary Sediment Basin;
Storm Drain Inlet Protection (e.g., hay bales, sand bags, gravel berm)
Outlet Filtering/Stabilization for Construction Dewatering;
Revegetation of Fills and Disturbed Soils
Onsite petroleum spill/leak response equipment and supplies and provision for their
proper disposal
Contaminated Soil. If contaminated soils are discovered during construction, you must
immediately cease all work in the vicinity of the contamination, contact the Alaska Department of
Environmental Conservation for instructions, and defer any further activity until you receive ADEC
approval to continue.
Endangered Species. The activity must not jeopardize the continued existence of a threatened or
endangered species, as identified under the Endangered Species Act, nor endanger the critical
habitat of such species.
Chris Kendrick
POA-2006-1416
Furrow Creek 06-A; time extension
Your signature below, as permittee, confirms that you accept and agree to comply with the terms
and conditions of~en~eral Permit 95-10N, as supplemented in this document.
SIGN PEF~IlTTEE TITLE
(L WN ) NAM 'AND
PRINT PERMITTEE (LANDOWNER) NAME AND TITLE
(DA~E)
(DATE)
Opinion of Compliance
The signature below confirms the Municipality of Anchorage's opinion that the project
described above meets the terms and conditions of Anchorage General Permit 93-10N.
/
· ./ ~ . ,<, L~ ~.~'<'''' ,
SI(~N MUNIC1/'PAL OFFICIAL, NAME & TITLE (DATE)
PRINT MUNICIPAL OFFICIAL, NAME & TITLE
(DATE)
When the work authorized by the Anchorage General Permit is still in existence at the time the
property is transferred the terms and conditions of the permit will continue to be binding on the
new owner(s) of the property. To validate the transfer of the permit and the associated liabilities
associated with compliance with its terms and conditions have the transferee sign and date
below.
(TRANSFEREE) (DATE)
Attachments: Final Project Plans (sheets 1-4 of 4, dated August 14, 2006; updated 8131106)
Current As-Built attached (updated Nov, 2009)
Chris Kendrick
POA-2006-1416
Furrow Creek 06-A; time extension
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT
MEMORANDUM OF UNDERSTANDING
BETWEEN MUNI~PALITY OF ,6~CI-/~RAGE
THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this
~ Dayof N~;'~m[¢.( or 200 C{, by and between Cl,/'~) /.IX ~,"~''
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Memorandum of Understanding agree as follows:
1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality
grants permission to Owner to utilize and operate an Advanced Wastewater
Treatment System (AWWTS), described as ~d~va~'P¢~ located
at Dcc,,~e~ /~c[ /-7 , Anchorage, Alaska.
2. Definitions.
A. Alteration. Any change to the design or function of an AWWTS that
Includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design. Prior to
performing any alterations to an AWWTS the owner must obtain a
Wastewater Disposal System Construction Permit from the Municipality
pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65.
B. Certificate of On-Site Systems Approval. An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with AMC 15.65.
These approvals certify that the systems are adequate for the homes that
they support and meet the codes that were in place at the time of system
construction.
C. Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
D. Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included in
the original design which would allow the AWWTS to continue to
perform as designed.
E. Permit (Construction) An On-Site Wastewater Disposal System
Construction Permit as defined by AMC 15.65.
F. Permit (Operating) An Advanced Wastewater Treatment System
Operating Permit. An annual permit, issued by the Municipality, that
allows the Owner to operate an AWWTS, upon meeting all the
requirements of this agreement, the conditions of Operating Permit, the
requirements of the On-Site Wastewater System Construction Permit and
all relevant provisions of AMC 15.65
3. Fee. Owner shall pay to Municipality an annual fee of 75_~c6;
($ ~/ .00), payable on or before the issuance of the operating permit and annually
thereafter. The annual fee is due on or before the anniversary date of the approval by the
Municipality of installed system.
4. Term. The term of this Memorandum of Understanding shall be for the life of the
AWWTS.
The term begins on the date of approval by the Municipality of the installed system and
shall continue while the AWWTS system is in use or operational or until the property is
sold or title is transferred by owner and a new certificate of On-Site approval is issued to
the new owner or transferee of the property.
5. Alterations~ Installation and Removal of Additional Equipment. Owner agrees
not to make any alterations, removal of parts or additions to the AWWTS without a
Construction Permit from the Municipality.
6. Maintenance and Repairs.
A. Tl~oughout the term of this Memorandum of Understanding, the Owner shall
maintain AWWTS in good repair. In addition, it shall be the responsibility of the
Owner during the term of this Memorandum of Understanding, and any extensions or
renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2)
maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs.
Further, Owner agrees to comply will all applicable ordinance, laws, regulations,
rules and orders for the AWWTS.
B. Owner agrees to provide the Municipality a written schedule of routine
maintenance and repairs which have been performed on the system pursuant to the
terms and conditions contained in the Owner's AWWTS Operating Permit. This
schedule shall be submitted to the Municipality annually upon the renewal of the
permit. The schedule of maintenance and repair contained in the Owner's AWWTS
Operating Permit is: x//~a ( I¥
C. Owner acknowledges that the f'me schedule for failing to maintain and repair an
AWWTS are codified in AMC 14.60.
D. Owner agrees that only maintenance, repair personnel certified by the
Municipality will inspect and make any necessary maintenance, repairs or permitted
alterations to the system.
E. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
F. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On-Site Systems Approval.
G. Owner agrees that the relevant provisions of the standard specification guidebook
for AWWTS is the governing professional guidelines for the construction,
maintenance and repair of the Owner's AWWTS.
7. Nonwaiver. The failure of either party at any time to enforce a provision of this
Memorandum of Understanding shall in no way constitute a waiver of the provisions,
nor in any way effect the validity of the Memorandum of Understanding or any part
hereof, or the right of such party thereafter to enforce each and every provision
hereof.
8. Amendment.
A. This Memorandum of Understanding shall only be amended, modified or changed
by a writing, executed by authorized representatives of the parties, with the same
formality of this Memorandum of Understanding was executed and such writing shall
be attached to this Memorandum of Understanding as an amendment.
B. For the purposes o.f any amendment modification or change to the terms and
conditions of this contract, the only authorized representatives of the parties are:
Anchorage: Purchasing Officer
C. Any attempt to amend, modify, or change this contract by either an
unauthorized representative or unauthorized means shall be void.
9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of
Understanding shall be brought in the Superior Court for the Third Judicial District of the
State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and
obligations of the parties under this Memorandum of Understanding.
10. Severability. Any provisions of this Memorandum of Understanding decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining provisions
of the Memorandum of Understanding.
OWNER:
By:
Date: ~
STATE OF ALASKA
MUNICIPALITY:
Title~ '
Date: /[/Zff~
)
)
THIRD JUDICIAL DISTRICT )
~regoin, g/instrument was a~, k, nowledged, before me this ~/~id~ay of
The
N(~ARY PUBLIC Fog AI.~4~CKA / ?
My Commission expires: ~'//;,~:2 ~'~ :
P