HomeMy WebLinkAboutNORTH SLOPE BLK 4 LT 11ANor'th lop lock 4 Lo1' 1 lA 050- 581 -23  Municipality of Anchorage Development Services Department ~i'~ ~' Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: OSPl11078 PID Number: 050-581-23 Name: Troy Davis Homes, Inc. Wastewater System: [] New [] Upgrade Address: 165 E. Parks Highway Wasilla, AK 99654 ABSORPTION FIELD Phone: Number of Bedrooms: 357-9394 4 [] Deep Trench I)I Shallow Trench [] Bed [] Mound [] Other: Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION .6 GPD/Ft2 4.7-5.5 Ft. Block: 4 Lot: 1 lA Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe: North Slope 2.6-3.5 Ft. 2 Ft Township: Range: Section: Fill added above odginal grade: Gravel Length: .5-2 Ft. 106 Ft. Well: [] New [] Upgrade Gr~ve~ width: Number of lines: I Distance between Ii .... 5-8 Ft. 2 >10 Ft Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Private 191 Ft. 190 Ft, 757 Ft2 ASTM D3034 PVC Driller: Date Ddlled: StaticWater Level: Installer: Date Installed: Sullivan Water Wells 6/13/2011 60 Ft, Pomraning Excavation 6/23-24/2011 Yield: GPM Pump Set at: Ft. Casing Height Above Ground: 20 2 Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~ To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: ~rom~ Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Gal. Material: Number of Compartments: Well >100' >100' N/A N/A >25' Steel Two (2) surface water >100' >100' N/A N/A % / LIFT STATION Size: Manufacturer: Lot Line >5' >10' N/A N/A Gal, "Pump on" level at: "Pump off" level at: in. High water alarm at: Foundation >5' > 10' N/A N/A in. in, Pump Make & Model Electrical Inspections performed by: Cur[ain Drain None Noted R .... ks: BENCH MARK Location and Description: Concrete Slab Lower Level. Assumed Elevation: 100.0 Ft. Inspections performed by: A. Harala Dates: 1st 6/23/2011 2nd 6/24/2011 ~;~'..' Development Services Department Approval Conditional Approval Date: Reviewed and approved by: /'.~ .... / ,)/:'~ /Z'/~ Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP111078 F /--108.2 =~1,250 Gallon ~J I SepticTank 5--' I ' 103.35 Page 3 of 3 PID No. 050-581-23 102.0 101.2 107.5 105.5 Finished Grade / / Existing Grade -- Geotextile Fabric Drainfield Rock 100.0--/ 92.8 53' (Trench Length) I Groundwater @ 93.5' "~ 6/10/11 NORTH TRENCH 102.0 104.6 103.8 Finished Grade / / Existing Grade Geotextile Fabric Drainfield Rock 99.1 92.8 53' (Trench Length) Groundwater @ 93.5' 6/10/11 SOUTH TRENCH PROFILE AS-BUILT No Scale 101.2 Permit Number: 0SPl11078 ~TH1 NORTH SLOPE '~ LOT 1 la, SUBDIVISION BLOCK 4 50,851 S.F. s4 Four Bedroom Home Sl 1~.6' B 34.1' S2 I 20.2' 39.6' FSV 39.2' 58.5' C4 I 32.6' 48.1' M1 I 78.8' 95.8' M2 74.5' 100.1' C5 79.1' 98.0' C6 25.5' 55.8' FCO (~) THA 2-45' Long x 5' Wide x 1' Effective Depth Absorption Trenches Existing Well Page 2 of 3 PID No. 050-581-2,' NO CONFLICTS THIS LOT PLAN AS-BUILT SCALE 1' = 40' LEGEND C5 - Cleon Out M1 - Monitor Tube FSV - Flow Splitter Volve TH - Test Hole FCO - Founcotion Cleon Out Well Log Permit Number: OSP 111078 Date of Issue S/2512011 Date Started: 611312011 Date Completed: 611312011 Property Description NORTH SLOPE Lot llA Block 4 Property Owner Name & Address: Parcel Identification Number: 05058123000 Is well located at approved permit location? Section: Town: TROY DAVIS HOMES 165 E. PARKS HWY. #204B WASILLA, AK 99654 Borel~ole Data: Depth Soil Type, Thickness & Water Strata From To Casing Sfickup 0 2 Fill 2 4 Overburden 4 6 Silt Sand Gravel W/Cobbles 6 22 Hardpan WlBouldem 22 89 Silt Sand Gravel W/Clay 89 109 Hardpan W/Cobbles 109 186 Sand & Gravel 485 191 X~Yes Range: [~No Method of Drilling ~] air rotary ~] cable tool Casing type: Wall thickness 0.es inches Diameter 6 inches Total: 190 feet Liner type: Diameter inches Depth: feet Casing stick-up above ground: 2 feet Static Water Level(firom top of casing) Pumping Level: feet after 1 hours pumping gpm Recovery Rate 20 gpm M~h0d of Testing: Air 6o feet Well Intake Opening Type Screened Start feet Stopped feet Perforations Start feet Stopped Grout Type: Be~ntonite dry granular Volume: 100 Pounds Depth ~ Start o feet Stopped 44 feet Pump Intake Depth: i~ct Pump size: HP brand name Well disinfected upon Completion? iX! ~-~ No Method ofdisinfection CHLORINE 50 PPM Comments: 172 Water Sample Results: Amenic: ....... ug/l Well Driller: Cole Sullivan Nitrates , mg/I Sullivan Water Wells Total C01ifiarm Bacteria co[onies/100mL P.O. Box 670272 ............... Chugiak, AK 99567 Other bacteria: col/[ OOmL (907) 688-2759 Attention: The property owner shall provide this log to DSD (onsite) and DNR within 30 days of completion. 12/85/2811 23:34 9872438742 Pump lnstl ~p ML~ / hp INC. PAGE 82/82 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: December 19, 2011 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 11A, Block 4, North Slope Subdivision Septic System As Built/COSA No bedrock was found at or near Lot 11A, Block 4, North Slope Subdivision. The well log for this lot and the adjacent Lot 12 indicate the absence of bedrock to nearly 200'. We are confident no bedrock or impermeable soil lenses are found within 6' of the bottom of the absorption trenches. Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System OSPl11078 05058123000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: May 25, 2011 to May 24, 2012 Design Engineer: ANDERSON ENGINEERING Subdivision: NORTH SLOPE Site Legal Address: NORTH SLOPE BLK 4 LT 11A G:0703 Owner/Address: COX MARVIN DEAN PO BOX 771287 EAGLE RIVER AK 995770000 Permit Site Mailing Address: 30740 SAGWON AVE, Eagle River Lot Size in Sq Ft: 50851 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. MUNICIPALITY Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan OF ANCHORAGE ~ Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. (~'-O- ~"'~l- Property owner(s)/4./)~hlu~ ~T,~..,(_./' (.~ Day phone Mailing address ,DO. ~o,< 7717--$7 ~ ~q'-_.,~-z.~_- ~_,'z-r2, ¢¢14' Site address ~,¢.d-co.d Legal description (Sub'd., Block 8, Lot) ./1)o.¢,-r~/ 5~r'~- S,,'~, ~b;c~: Legal description (Township, Range & Section) Lot Size ~O~ ~S'~ Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: ([~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial ~ Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Sig~-~tu~e of proper~y owner or authorized agent) Perrr~t/Rush Fees: "D'~e of Payment: Receipt Number: Permit No. ~'~ V~ti~ar-Fees: Date of Payment: Receipt Number: Waiver No. G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677..7766 (FAX) June 10,2011 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1 lA, Block 4, North Slope Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 11A, Block 4, North Slope Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. No existing wells or septic systems are closer than 100' from the proposed well or septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated silty gravel with sand (GM). The percolation rate of the soil was determined to be between 6 and 15 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and 2 - 53' long by 5' wide by 2' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 5'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the southwest at a grade approximating 10%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface Lot 11A, Block 4, North Slope Subdivision June 10, 2011 Page Two water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: ]. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments Z o ALTERNATE SITE 2-45' Long x 5' Wide x 1' Effective Depth ~Absorption Trenches ®TH1 Existing Well NORTH SLOPE SUBDIVISION ~.. LOT 11A, BLOCK 4-  50,851 S.F. s4e o v ~6 ~' ~ Proposed ® Well Four Bedroom Home / / Gallon )tic Tank TH2 CO 2-55' Long x 5' Wide x 2' Effective Depth Absorption Trenches NO CONFLICTS THIS LOT SITE PLAN SCALE 1' = 40' LEGEND CO - Clean Out MT - Monitor Tube FSV - Flow Splitter Valve TH - Test Hole LOT 11A, E.~) cci BLOCK 4, NORTH SLOPE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Perc. Rate: 6 to 15 Min./Inch 1,000 Gallon Septic Tank Application Rate: .8 GPD/SF 2' Drainfield Rock 4 Bedrooms X 150 GPD/.8GPD/SF (Application Rate) = 750 SF Absorption Area 750SF/5 SF/LF*.7 (Red. Factor) = 105 LF Trench Length THEREFORE: Construct 2 Absorption Trenches Each 53' Long x 5' Wide x 2' Effective Depth. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 5' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Provide Flow Splitter Valve to Assure Even Flow to Each Trench. '6" 11 1011 Natural Backfill Geotextile Fabric 4I' Perforated PVC (Holes Down) -- Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION -- -- ~(~--~c~ .... ~;;,~%..o..~...~,~;, NOTE: Grade Area Over Trench to Drain Away. ,".~ ."' ~,~'~. M n m m ' ' - .-' 49th ~-~ u 6 Separabon From Bedrock. _-.....~ ............ .~ ............. ,~ ..... .~.,....~ Minimum 4' Separation From Groundwater. ~.~__ ~,.~,~./. Minimum 200' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. . ~6~,/~-... No. Minimum 10' Separation From Water Services in the Area ~'~'."-.~--"~_~,~ Minimum 10' Separation From Trench Sidewall to Trench ~idewall.'ee~,~l~'i~'(~'~_~.~ Performed For: Legal Description: COMMENTS Municipality of Anchorage Development'Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.~i,anch~raqe.ak.u$ , (907) 343-7904. Soils Log -'Percolation Test 2011 Pomraning Excavation, LLC DatePerformed: 6 / 2 / North Slope Sub&, L 1 lA, B 4 Slope WAS GROUND WATER ENCOUNTERED? No IF YEs, AT WHAT DEPTH? o Depth to Water After ~. p. MOnitoring? /('[ ~ E Township, Range, Section: ,/ Reading Date · Gross Time Net Time Depth to Water Net Drop 6/6/2011 I~': ~f,~ ~' ~,~ ''~ / /~:~1 / ~,~" PERCOLATION RATE 12 (minutes/inch) TEST RUN BETWEEN - 4.0 FT AND the test cavity was presoaked pdor to testing- PERC HOLE DIAMETER 7" --4.5' FT PERFORMED BY: A. Harala I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: SOILS LOG - PERCOLATION TEST TEST HOLE 1 OR ORGANICS 2-- 3-- SILTY SAND/ 4 -- SP/GP GRAVEL ~ W~ ~ W/ROCKS 7 BOH X 8-- TH .1o -- TH-1 TH-2 WAS GROUND WATER SLOPE 14 -- ENCOUNTERED? Y .15 -- iF YES, AT WHAT ; ~ TH 16 -- DEPTH? -6-' X '17 -- DEPTH TO WATER AFTER MONITORING? -5'- 18 DATE: 5/23/11 DATE PERFORMED: 05/06/11 READING DATE CLOCK WATER TIME NET TIME LEVEL NET DROP READING I 5/6/11 9:48 5.85 I 2 9:58 10 MIN 10.36 4.51 I 3 9:58 5.85 4 10:08 10 MIN 10.30 4.45 5 10:08 I 5.85 6 10:18 I 10MIN 10.28 4.43 PEROLATION RATE 2.3 (rain/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 2 FT AND 3 FT COMMENTS: Test hole excavated by FLINTSTONE ENTERPRISES. Test hole was pre-soaked before perc test. Test run for one hour. Last three readings shown. PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC, LLC '" FOR CONSTRUCTION P.0. B0X 102954 ANCHORAGE, AK 99.510 PHONE (907) 272-8218 FAX (907) 272-8211 Scale NORTH SLOPE S/D, BLOCK 4, LOT 11A '~'~'~"$'t~:'P~Fn'¢~&'~ o5o-581-2~ MARVIN DEAN COX SOILS LOG EAGLE RIVER, AK 99577 ~c'Yc')I~P/~0FESS~0~'ki~.~."¢""'~ Sheet READING DATE CLOCK WATER TIME NET TIME LEVEL NET DROP READING I 5/6/11 9:48 5.85 2 9:58 10 MIN 10.36 4.51 3 9:58 5.85 4 10:08 10 MIN 10.30 4.45 5 10:08 5.85 6 10:18 10 MIN 10.28 4.43 SOILS LOG - PERCOLATION TEST TEST HOLE 2 SILTY SAND/ 4 -- SP/GP GRAVEL W/ROCKS 5~ : ~ 5/20/201 7-- X 8 TH BOH 9~ 10 -- 11 -- ~5 ~ IF YES, AT WHAT TH 16 ~ DEPTH? ---' X 17 ~ DEPTH TO WATER AFTER MONITQRING? -6.5'- ~ 8 DATE: 5/20/11 CLOCK WATER DATE PERFORMED: 05/06/11 R~DING DATE TIME NET TIME LEVEL NET DROP READING ~ ~ 5/6/11 10:32 5.40 2 10:42 I 10 MIN 8.69 3.29 3 10:42 - 5.40 4 10:52 10 MIN 8.59 3.19 5 10:52 - 5.40 e 11:02 10 MIN 8.54 3.14 PERO~TION ~TE 3.2 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BE~EEN 2 FT AND 3 FT COMMENTS: Test hole excavated by FLINTSTONE ENTERPRISES. Test hole was pre-soaked before perc test. Test run for one hour. Last three readings sho~. PERFORMED BY: Steven R. P~none, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST~ NOTES:9g.~}~[, D~te FOR CONSTRUCTION P.0. BOX 102954 ANCHORAGE, AK 99510 ~&~l"' ~:~?~a 5/25/11 PH0iE (907) 272-8218 r~X (907) 272-8211 ~... ~..~ ~a sco~e MARVIN DEAN COX ¢J~~E~ 8~9 ,:/~;~ PERMIT NO. P.O. BOX 771287 ,~.. ..~ 0SP1~1078 -~--__~~ 4 OF 4 CLOCK WATER READING DATE TIME NET TIME LEVEL NET DROP READING 1 5/6/11 10:32 5.40 2 10:42 10 MIN 8.69 3.29 3 10:42 - 5.40 4 10:52 10 MIN 8.59 3.19 5 10:52 - 5.40 e 11:02 10 MIN 8.54 3.14 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 1. 050-58~-23 COSA# C)-~P,~ Expiration 'Date: GENERAL INFORMATION Complete legal description Lot 11A, Block 4, North Slope Subdivision Location (site address) 30740 Sagwon Avenue Eagle River, AK 99577 Current Property owner(s) Troy Davis Homes, Inc. Mailing addreSs 165 E. Parks Highway Wasilla, AK 99654 Day phone 357-9394 Lending agency Day phone Mailing address 2.'.NUMBER,OF B~:DROOMS: - 3. ,T~YPE OF'WA~TER SUPPLY: Individual W~II Individual Water Storage comrnunity Class __ Well Public Water System Real Estate Agent · ~;. ,~,il~rf~,,.Address Unless othefwise~requested, COSA will be held by DSD for pickup. "'~:i; Four (4) Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE ~/'~ Approved for. Disapproved. Conditional approval for bedrooms. Phone 522-7773 bedrooms, with the following stipulations: By: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other ~'~¢T4-~Origina' certificate Date: /2- Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Lot 1 lA, Block 4, North Slope Subdivision Legal Description: A. WELL.DATA Well type Private Date completed 6/13/201 Total depth 191 ft. If A, B, or C provide PWSID # ~ Sanitary sea! (Y/N) Y Cased to 190 ff. FROM WELL LOG 6/13/2011 60 ff. 20 g.p.m. Parcel ID: 050-581-23 Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Arsenic: N/D mg/I B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Foundation cleanout (Y/N) .Y . Date of pumping New Construction C. ABSORPTION FIELD DATA Date installed 6123.24/11 Length 106 ft. Total depth 5.7-7.5 ft. Well Log (Y/N) Y Wires properly protected (Y/N) ...... Casing height (above ground) >24. AT INSPECTION Nitrate .434 mg/L Date of sample: 11/16/11 Collected by: g.p.m. A. Harala Number of Compartments Two Depression over tank (Y/N) __ Pumper Date installed 6/23/2011 Cleanouts (Y/N) Y High water alarm (Y/N) Soil rating (g.p.d./ft2 or ft2/bdrm) .8 GPD/SF Width 5-8 ft. Eft. absorption area 757 ft2 Monitoring tube System type 5' Wide Trench Gravel below pipe 2 Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) __ For ~ bedrooms Fluid depth in absorption field before test in. Water added~ gal. New depth Elapsed Time: ~ min. Final fluid depth in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date in. in, g.p.d. LIFT STATION Date installed "Pump on" level at Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off" level at Cycles tested in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main N/A Sewer/septic service line >25' Animal containment areas >50' On adjacent lots >1oo' On adjacent lots >1oo' Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >lOC' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field . >5' Surface water >100' Property line >10' Building foundation >10' Water Service line >10' Surface water >lOC' Curtain drain None Noted Wells on adjacent lots >lOC' COMMENTS: Water main >10' Driveway, parking/vehicle storage >25' · certify that I have determined through field inspections and ~ ~ . -e~ ~. ~ . ~ ~ rev,aw of Mun/c,pal mcords that the above systems are ,n ~ ~~~ ~eeee ~e~e.~ confo~an~ with MOA COSA guidelines in effect on this date. ~ '~~ Engineer's Printed Name Michael E. Andemon. P.E. ~a~% ":' ~:~81 ..~ COSAFee $ (~ Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number SGS ReL# 1115631001 Client Name Anderson Engineering Printed Date/Time 11/23/2011 16:39 Project Name/# North SlopeS/D, Add#2, LI l, B4 Collected Date/Time 11/16/2011 13:45 Client Sample ID Private Well Water Laundry S Received Date/Time 11/16/2011 15:50 Matrix Drinking Water Technical Director Stephen C. Erie Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 11/16/11 11/23/11 NRB Waters Department Total Nitrate/Nitrite-N 0.434 0.100 mg/L SM20 4500NO3-F B (<10) 11/22/11 AYC Microbiology Laboratory Colony Count 0 col/100mL SM20 9222B A (<200) 11/16/11 DLC Fecal Coliform 0 col/100mL SM20 9222B A (<1) 11/16/11 DLC Total Coliform 0 col/100mL SM20 9222B A (<1) 11/16/11 DLC 10 ~E~LL o ORAiN LOT I1A BLOCK 4 HAS 50,851 SQ.FT. OF AREA -77. EXISTING HOUSE RETAINING W~ 'CL£4NouT -1.$' CANT RETAINING WALL ~S~PziC~ ~5 0 ~5 30 60 / ~ / FOR: TROY DAVIS HOMES LanMark Surveying, Inc. 9330 Vanguard Drive, Suite 131 Anchorage, Alaska 99507 (907) 562-6050 Date 10-11--11 Scale 1" = 30' Grid As-Built 603 &703 2110170 Drawn by CEF Field Book 238 I hereby cerLify that the property described hereon has been surveyed by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto unless otherwise shown. That no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Listed distances prevail over scaling. Reproduction may cause distortion. Legal Description Lot 1 lA Block 4 NORTH SLOPE SUBDIVISION ADDITION NO. 2 CHARLES E~ FORBES : ~ ~ ~'~',. 10-13-11 ,' 3 ~