Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CINERAMA TERRACE BLK 3 LT 7
Cinerama Terrace Block 3 Lot 7 #020 - 541 -13 On-Site Water & Wastewater System Permit OSPl11092 02054113000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: Tax Code Number: Work Type: Initial Permit Effective Dates: June 14, 2011 to Design Engineer: SPURKLAND ENGINEERING Subdivision: CINERAMA TERRACE June 13,2012 Site Legal Address: ClNERAMATERRACE BLK 3 LT 7 G:3241 Owner/Address: MOOSES GIZZARD LLC 6424 SW LOOP DR PORTLAND OR 972210000 Site Mailing Address: 9050 SNOW BEAR DR, Anchorage Lot Size in Sq Ft: 71333 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Permit includes waiver OSP111104 allowing the drainfield to be 35 feet from a slope >25%. Received By: Issued By: Date: Date: Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchora,qe, Alaska 99519-6650 ® (907) 343-7904 · Fax (907) 343-7997 ,.http:llwww.muni.orqlOnsite Development Services Department On-Site Water and Wastewater Proqram epa]-tment **** VARIANCE/WAIVER REVIEW **** WR#: OSPl11104 HA#: Permit/C: OSPl11092 PID#: 020-541-~ 3. Legal Description: Cinerama Terrace, Block 3, Lot 7 Engineer: Spurkland En,qineerin,q Applicant: Will Henson. Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the slope greater than 25% has been approved. The approved separation distance is 35 feet. This waiver approval applies to the existing absorption field to slope separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 6/14/11 Approved by'~~. ~ Name of Reviewer Rec,#: 036922 Amount: $200.00 Date Paid: 6114111 **** VARIANCE/WAIVER REVIEW **** UNICIPALITY Community Development Department ~'--~~ Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan OF ANCHORAGE Phone:907-343-7904 Fax:907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Property owner(s) Mailing address Site address Legal description (Sub'd., Block & Lot) kLin4c~m~, 14~( Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: ([~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial .~, Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature'of property owner or authorized agent) Per Rush Fees: Date of Payment: Receipt Number: Permit No. O'b Waiver Fees: ,i~, ~ Date of Payment: Receipt Number: Waiver No. ~'~7~ G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) Environmental Consulting and Design SEPTIC SYSTEM DESIGN Cinerama Terrace Block 3 Lot 7 Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 June 1,2011 Subject: Septic System Installation Permit Snow Bear Lane Ladies and Gentlemen: I am writing to request a permit a well and septic system installation permit for the above referenced property. The proposed system will serve a 3-bedroom single-family residence. A soils log, design calculations, a site plan, design drawings and construction specifications are enclosed for your review. Design Calcs: No Groundwater observed to a depth of 16 feet below ground surface (5/19/2011) Soil Rating. From Testhole 8/3/2005 5.3 min/in = 1.2 gal per sq.fi/day No. of Bedrooms 3 Required Area per Bedroom: 150/1.2 =125 sq.ft. Total area required: 125 x 3 = 375 sqft System: We are proposing a 1000 gallon septic tank, and a shallow trench absorption field. The absorption field will be 50 feet long and 5 feet wide and contain 3.5 feet (600 sq.ft. effective) of sewer rock. Soils: A test hole was excavated on August 3rd, 2005. A second test hole was excavated on May 11,2011. See the attached soil logs. Ground water was monitored for through May 19,2011. Ground water was not observed. Surface Water: There are no surface waters within one hundred feet of the proposed septic system upgrade. o Topography: The lot slopes to the northwest at approximately 25-30 ¼. The entire area is th 203 West 15 Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Environmental Consulting and Design I heavily vegetated and in our opinion the day lighting of septic system effluent is not a concern. Waivers: ,~gOfi~ ~[~/9~ The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or concerns, please contact me at 279-3916. Sincerely, Lars Spurkland, P.E. Civil Engineer 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Environmental Consulting and Design Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 June 13, 2011 Subject: Slope Waiver Cinerama Terrace Blk 3 Lot 7 Ladies and Gentlemen: I am writing to request a slope waiver for the septic system absorption field at the above referenced property. The proposed absorption field is 35 feet away from a break in the slope (25 % to 50 %). A drawing has been submitted showing the existing conditions. According to MOA onsite slope waiver guidelines, effluent from this system does not appear to be at risk of day lighting. The current configuration of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. If you have any questions or concerns, please contact me at 279-3916. Sincerely, L-a~s Spu~kland, P.E. Civil Engineer 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net ,~ ta ~, '{" / Lo't;2 ~ ..~ IIii ~ I I I , ~ ~ ~11 ~ ~ ~ /Lot 7 I ~ ~ ~o~ ', ~ '~ / ~, ,~" / I j ~NOTE: THIS IS NOT ~ S~RV~D P~ WE~ · SEPTIC ~ ..... L~AT/ONS TAKEN ENOW ON-SITE WATER AND ~ASTE WATEN ~.l,..:~'~v~ ......... BEPARTWENT B~UWENTATION. A~ LOC~TIONS SHOWN ARE SChLE~ i' = 100 FE SPURK~NO ENGINEERING CIN~RAMA T~RRAC~ BLK 3 LT 7 SEPtiC SYSrEW DES/ON 20~ W 15rH. AVENUE DESIGN CONCEPTS, INC. DAF& JUNE 1, 2011 ANCH. AK. 9950~ SNOW BEAR ~NE SHEET: I/S (90Z) 279-~9~ PERMIT ~ OSPXXXXXX PIS ~ 011-~6~-0~ Cineromo TerroceBSL 7Bl. dw N ._ . X / ~ ................ ~... SPURK~ND ENGINEERING CINERAMA TERRACE BLK 3 LT 7 SEPtiC SYSTE~ DESIGn ZOZ · ~SrH. ~VE~UE OES~ CONCEPTS, ~C O~rE: ~U~E ~, ANCH. AK. 99501 (907) 279-J916 SNOW BEAR ~NE SHEET: 2/3 ORID: 3241 PERMI~ ~ ~2PXXXXX PIB ~ 011-262-02 Cinero~o TennoceB3L 7B2, d~9 t tandar'd Trench: 5' Wide 50' Lan9 6.$' 9eep Max 3.5' Sewer` Rock 3' Cover' Min. © ND SCALE 1000 9ol Sep tic tank ~ l}ouble Clean Outs ~ © / Mom/tom Cleonouty- _ Silt Bonnie 3,5 Ft of' Septic Rock Effective ND SCALE 1000 9ol, septic tank 203 ~/15th Ave Anchorage Ak 99501 279-3916 CINERAMA TERRACE BLK 3 LOT DESIGN CONCEPTS, INC SNOW BEAR LANE 7 SEPTIC SYSTEM DESIGN DATE: JUNE I, 2011 SHEET: 3/3 GRID: 3241 PERMIT tf OSPXXXXXX PARCEL ID If.O~ CINERAbIATERRACEBtL7D$.DWG II Performed For: Legal Description: 12- 13- 14- 15- ~7- , Lof SA/~D G~JXgf::L.. Municipality of Anchorage Development Services Department Building Safely Division On-Site Water and Wastewater Program 4700 South Bmgaw St. P.O. Box 196650 A~chorage, AK 99519-6650 www.ci.anchoraqe.ak.us (907) 343-7904 Soils Log - Percolation Test Oo , lA Date Pe, o med: J~lO~.k 3 (~t'~.~i~, ~¢~C~ Township, Range, Section: Slol~e WAS GROUND WATER Site Plan IF YES, AT V'IHAT DEPTH? Depth to Water After Monitoring? Reading II ID ¥~" I0 '16" Io 'l~. " " IO'J~" " Dale: PERCOLATION RATE TEST RUN 8ETV/EF.N Date I Gross Time Depth to Water t Net Drc3 I It: '.tq t "'Cie" :EFFORMED BY: L~¢..~ Sour I CERTIFY THAT THiS PEqFORMED Ihl ACCORDANCE ~//ITH ALL STATE AND MU,"I~CIPAL ~uIOE'LINES hN ~, FF_.CT OH T~IS DATE. DATE: Municipality of Anchorage ..~ (I~IG't1~EJ~R'~ Development Se~ices Depa~ment Building Safe~ Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 (907) 343-7904 Soils Log-Percolation Test Pe,ormed For: i[ ~ ~ Date Pe,ormed: LegalOescription: C~~.~ ~C~ ~J~ ~ ~ Township, Range, Section: Slope Site Plan 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 15- 16- 17- 20- WAS GROUND WATER ENCOUNTERED? IF YES, AT VVHAT DEPTH? Depth to Water After Monitoring? Date: s L o P E Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE .~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ?~ ~ FT AND '~, ~) FT COMMENTS PERFORMED BY: SF~/,,Z/~_/~.J .~..".~1~i~7,~, ~ ~- I ~--~"-'~ ,._~ '.~~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AN~ MUNICIPAL GUIDELt'NES IN EFFECT ON THIS DATE. DATE: Subject Property: Date: General: 1. Environmental Consulting and Design I Single Family On-site Wastewater Disposal System Construction and Material Specifications CINERAMA TERRACE BLOCK 3 LOT 7 June 1, 2011 The owner shall contract with a contractor to perform the work outlined in these specifications and plans in accordance with the attached MOA permit. There is not contractual arrangement between the contractor and the Engineer. The Engineer shall be the owner's representative and will inspect the work to document the contractors activities. Final acceptance of the contractors work rests with the owner and the MOA. The scope of the project includes the procurement and installation of a 3-bedroom on- site wastewater disposal system at the location depicted on the attached site plan drawings. The scope of the work also includes the installation of a new 1000 gallon septic tank, a drainfield comprised of i trenches,5-feet wide x 50-feet long, 6.5 feet deep, with 3.5 feet of septic rock below the distribution piping. All components of the proposed septic system must be constructed a minimum of 100 feet from any surface water or water wells in the area. A minimum of 4 feet of earthen cover is required over the septic tank and a minimum of two feet of cover is required over the drain field. In addition to the required earthen cover, 2-inch thick, 40 psi, direct bury board foam shall be installed directly over all installed piping. Construction shall be in accordance with the approved site plan and design drawings and any special provisions noted on the Municipal well and/or septic permit. All materials, components, workmanship and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA, Development Services Department, On-site Water and Wastewater Program (DSD) policies. The contractor is responsible for obtaining all underground utility locates, layout of the proposed system, and verifying and maintaining all required separation distances to lot lines, surface water, wells, steep slopes, etc. The property owner shall be responsible for final grading any depressions formed from settlement of backfill material. The property owner is also responsible for vegetation of all areas disturbed by septic system installation activities. Contractors installing wastewater disposal systems must be certified to do so by the MOA DSD, On-site Water Wastewater Program. Property owners installing their own systems must receive advanced approval from MOA DSD prior to system installation activities. The contractor shall ensure that ALL materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. Refer to "Standards and Specifications for Component Parts and Materials Used in the 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Environmental Consulting and Design I Construction of On-site Wastewater Disposal Systems", Dated December 2000, as provided by MOA DSD, On-site Water and Wastewater Program. Septic Tank Installation: 3. 4. 5. 6. 9. 10. 11. 12. 13. 14. 15. 16. A new septic tank, of the size specified in the design drawings, shall be procured from a qualified manufacture/supplier if the existing septic tank is found to be defective. Construction shall include two 4" diameter cleanouts for pumping access. The burial rating of the tank shall be adequate for the actual burial depth encountered. The tank shall be level and sufficiently bedded to prevent settling of shifting of the tank. All standpipes on the tank shall extend a minimum of 12inches above the final grade. Tanks installed with less than 4 feet of cover shall be insulated. The sewer service line from the house to the tank shall have a minimum slope of 2% unless prior approval is obtained from the engineer. The inlet and outlet lines from the tank shall be bedded in drain rock or the soil shall be sufficiently compacted to prevent future settlement of the soil. Septic tank inlets, outlets and cleanouts shall be fitted with water tight couplings. A cleanout shall be installed I to 4 feet from the foundation. Post tank cleanouts shall be installed per MOA requirements. Does not apply to pressurized lines. Tn areas with high ground water, the septic tank shall be sufficiently anchored to resist buoyancy forces when there is not adequate soil cover to resist uplift force. The contractor shall refer to the engineer for direction regarding this matter. The tank backfill shall be graded sufficiently to ensure positive drainage away from the tank. All holding tank and lift stations shall have an audible and visible alarm inside the residence being served. All lift stations shall be wired in compliance with all MOA guidelines and the Uniform Electrical Code. A municipal electrical permit and inspections must be obtained where required by the MOA. The contractor shall verify that the septic tank/lift station is a minimum of 100 feet from any residential water well, 150' from any class 'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. The contractor shall remove or abandon the existing tank in compliance with the Uniform Plumbing Code. Drain field Construction: 1. The drain field shall be excavated to the dimensions outlined in the design drawings. any discrepancies are noted, contact the engineer immediately for clarification. 2. The drain field shall be installed parallel to slope contours. 3. The bottom of the drain field shall be within 2' of level. If the sidewalls or bottom of the excavation become smeared, they must be raked or scarified prior to the placement of filter sand or drain rock. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net 9. 10. Znspections: 1. Environmenfol Consulting ond Design I The drain field must be a minimum of 5 feet from the test hole excavation. Distribution pipe is to be installed level with perforations facing downward, atop a level bed of drain field rock. Septic rock shall then be placed atop the distribution piping to provide a minimum of 2" of cover, level across the entire width and length of the trench, above the piping. A silt barrier must be installed at between the final drain rock and the native soil backfill. The silt barrier shall cover the entire drain rock surface. Monitor tubes must be 4" in diameter, installed in the locations depicted on the design drawings, and extend a minimum of 12" above final grade. The portion of the monitoring tube below the septic rock must be perforated and the portion above the drain rock shall be solid. Backfill over the final gravel layer must not be less than 2 feet. Insulation must be installed when the backfill depth is less than 3 feet. Drain field back fill shall be mounded to prevent depressions from forming due to subsequent settlement of backfill material. The contractor shall verify that the drain field is a minimum of 100 feet from any residential water well, 150' from any class 'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. A minimum of two inspections are required by the Municipality of Anchorage. These inspections must be conducted under the supervision of a Professional Engineer licensed to practice in the State of Alaska. The first inspection must be conducted after the excavation of the drain field and before the placement of any gravel. The septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, stand pipes, cleanouts, and insulation, but before the placement of any backfill. The contractor shall provide a legible copy of all field notes relating to system layout and construction to the engineer for the use in preparing the record drawings. The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours notice is required prior to the start of construction. Tf necessary, a preconstruction meeting will be held on-site. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net