Loading...
HomeMy WebLinkAboutSOUTHPARK #2 BLK 1 LT 23outhpark lock I Lot 23 020- 501 -13 On-Site Wastewater Disposal System Permit OSPl11120 02050113000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 EImore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: Tax Code Number: Work Type: Initial Permit Effective Dates: June 28, 2011 to Design Engineer: ANDERSON ENGINEERING Subdivision: SOUTHPARK #2 June 27,2012 Site LegalAddress: SOUTHPARK#2 BLK 1 LT 23 G:3236 Owner/Address: GMB FAMILY PARTNERS LTD 2431 W 100TH AVENUE ANCHORAGE AK 995152213 Site Mailing Address: 4711 Southpark Bluff DR, Anchorage Lot Size in Sq Ft: 27304 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation tests in each strata within the effective depth prior to the construction of the septic field. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. AMC 15.65.060.B3 Date: ~/?,~//i/ Date: ~ ~'~,/' MUNICIPALITY Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan OF ANCHORAGE k,~,~ Phone: 907-343-7904 -'- Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. ~)Z.¢?- -T'~:.l ... /.~ Property owner(s) ~ ,.=--~ T' /-/~*,~'4 L.:~~ Mailing address Day phone Site address Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size 'Z'~ '¢'C'*¢, Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: THIS APPLICATION IS AN: ([~ all that apply) Absorption Field ~ Initial ~ Septic Tank ~[' Upgrade [] Holding Tank [] Renewal [] Privy [] Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) ~Rush Fees: Date of Payment: Receipt Number: Permit No. O~L)'~ Waiver Fees: Date of Payment: ~//'P~ ~//! Receipt Number: O I ~ I "Z- ~ Waiver No. ~.GI:::) / t { {..3 ~ G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677~7766 (FAX) June 21,2011 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 23, Block 1, Southpark Subdivision No. 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 23, Block 1, Southpark Subdivision No. 2 intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The subdivision is currently served by a Class A Water System. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site and the proposed water service. No existing wells or septic systems conflict with the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated poorly graded sand and gravel (SP/GP) from 1.5' to 5.5' and silty sand (SM) to 10'. The percolation rate in the upper layer was determined to be 4 minutes per inch with the lower layer at 14 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An average application rate of 1.0 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and a 38' long by 3' wide by 8' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 2' below the surface and the total depth will be 10'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench is virtually flat with a slight grade to the west. The new trench will be constructed parallel with the contours Lot 23, Block 1, Southpark Subdivision No. 2 June 21,201'1 Page Two of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 24 NOTE: OF ~/~ Subdivision S~ed by A~U Adjocent Septic Sy~tem~. PLAT NO. 85-215 SOUTHPARK SUBDIVISION, ADDN. LOT 25, BLOCK 1 27,504 S.F. SECTION UNE ESblT. NO. 2 LEGEND SV - Septic Vent CO - Clean Out MT - Monitor Tube TH - Test Hole FCO - Foundation Cleanout / / / SYSTEM DESIGN 1,250 Gallon Septic Tank w/38' Long x 3' Wide x 8' Effective Depth Absorption Trench. / Alternate Site Four Bedroom Home / J / J j J 3' SITE PLAN SCALE 1' = 40' LOT 23, BLOCK 1, SOUTHPARK SUBDIVISION NO. 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 4-14 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.0 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/1.0 GPD/SF (Application Rate) = 600 SF Absorption Area 600 SF/16 SF/LF = 37.5 LF Trench Length THEREFORE: Construct a 38' Long x 3' Wide x 8' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 10' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 200' Separation from Class A Well in the Area. 1611 Natural Backfill ~ Geotextile " I Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION -- ---~-sc~--aT- .... .~..~ ........... Performed For: Legal Description: 2- 3- 4- 5- 6- 9- 10- 11- 13- 14- 15- 16- 18- 19- 20- COMMENTS MunicipalitY of Anchorage ~ Devel°pment Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. ci.anchoraqe.ak, us (907) 343-7904 Soils Log - Percolation Test MERIT HOMES Southpark Subd., No. 2, L 23, B 1 Slope .11I?, Ill Iii WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water After Monitoring? Date: Apr 30, '11 Da.~,~ormed: _Apd121,2011 Township, ,~ec.t_!on: ~ _ Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE , /,~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ' "~1/,~,./ ft AND ~ FT TEST CAVITY was presoaked prior to Percolation- PERFORMED BY: A. Harala j CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.. DATE: Performed For: Description: 2- 8- 9- 10. 11- ,~ '13- ~4- 15- ~.~l¢ 17- 18- 19- 20- COMMENTS TEST HOLE 2 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 EJmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchorage.ak.us (907) 343-7904 Soils Log - Percolation Test MERIT HOMES WAS GROUND WATER ENCOUNTERED? No IF YES, ATWHAT DEPTH? dry Depth to Water After Monitoring? nO water Date: Apr 30, '11 Reading Date . Gross Time Net Time 'Depth to Water Net Drop PERCOLATION RATE '~ (minutes/inch) PERC HOLE DIAMETER 8" TEST RUN BETWEEN 3 FT AND 3 1/2 FT Test Cavity was presoaked prior to testing - PERFORMED BY: A. Harala I CERTIFY THAT THIS TEST WAS PERFORMED fN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10- 11- 13- 14~ 15- 17- 18- 19- 20- Performed For: Legal Description: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchorage.ak.us (907) 343-7904 Soils Log - Percolation Test MERIT HOMES Southpark Subd., No. 2, L 23, B 1 Slope WAS GROUND WATER ENCOUNTERED? ' NO IF YES, AT WHAT DEPTH? L Depth to Water After ~0 ~,~EP Monitoring? Date: Apr 30, '11 Reading Date Gross Time Net Time Depth to Water Net Drop Apr 30, '11 PERCOLATION RATE .4 (minutes/inch) PERC HOLE DIAMETER 7" TEST RUN .E~EN "'1 ,T AND - "/,V,~,T COMMENTS TEST CAVITY was presoaked prior to Pemolation- PERFORMED BY: A. Harala I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522'7773 677-7766 (FAX) June 28,2011 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 23, Block 1, Southpark Subdivision No. 2 Absorption Trench to Slope Waiver Dear Onsite Services Engineer: Lot 23, Block 1, Southpark Subdivision No. 2 has limited area for construction of a septic system due to a steep slope to the northwest. We have located an area with acceptable soils, but it is situated slightly more than 46' from a break in grade greater than 25%. We are therefore applying for a waiver allowing placement of the absorption trench at this location. The trench is aligned from southeast to northwest and only 4' of the trench is closer than 50' from the bluff. A drawing is attached showing the impact of the trench on the slope. We therefore recommend a waiver be issued allowing placement of the new absorption trench within 40' of a slope greater than 25%. Sincerely, Michael E. Anderson, P.E. Attachment OF- 4/ ~"'X~ ....... ~ ...... ~ .......... ~'""~'""¢ ~g~ MICHAEL E. ANDERSON r-- z 0 0 cq 0 Z ~ 0 0 0 0 0'~ 0 0 --4 0 0 (..o 0 0'1 0 0 --' ~ ' 0 Cn 0 On Property Line