Loading...
HomeMy WebLinkAboutSEAVIEW HEIGHTS BLK 2 LT 6 (LT 14)eC VleW Height lock 2 Lot 6 (lot 14) 011-261 -13 !:"() U C I~ 6-650 ((}37) :~64-4111 , NVIRONM','!_i'xlT/:',i. '2r}' i'(]TiON <Permit ~: 820873 January 31, 1983 TO: Permit Applicant Subject: Lot 14 Block 2 Tract 6 Seaview Heights Subdivision A permit issued by this department for an individual well and/or on-site sewer system has expired as of December 31, 1982. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log needs to be sent to this department for documentation of the installation date and to close the permit. ' If a private engineer inspected the installation of the on-site sewer system, please have them send us the as-bui!ts for our files and documentation. If there are any further questions, please call this office at 264-4720. Sincerel.~~ ~ Robert C. Pratt, R.S. Acting Program Manager Sewer and Water Program RCP/Ijw enc: Copy of Permit SWP/057 PERMIT NOo APPLICANT DAVE RAMME LOCATION LEGAL l-lLIr-~ I C: I F.~RL I T'-,-' C~F FtI'~C:HI~IRRGE /~/~~ DEPARTMENT ~ERLTH AND ENVIRONMENTAL ~TEOTION 825 'L~ ST n - ' --- REET., RN_.HORR~E., AK. 99~1 264-4720 ON--~ X TE ~E~E~ PE~ Z t 5- c~ ., ,-. /,, 2736 E 20TH 9950i 349-656i~/ -- LOT SIZE 999999 SQUARE FEET TYPE OF ~ _OIL ABSORPTION SYSTEM IS' TRENCH MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING (SQ FT?BR>= 85 THE REQUIRE[:, SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEF'TH= l~.-_~ LEf-IGTH= laRR%,,'EL [:"EPTH= 1 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVRTION (IN FEET). REI;;!U I RED SEF"T I C TRI'-IK S I ZE= ::!_1a00 GRLLOI'4S PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TL40 <2> I NSPEOTIO[4S RRE RE(;ILIIRED BRCKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION RND RPPROVRL BY THIS DEPRRTMENT WILL BE SUBJECT TO.PROSECUTION. MINIMUM DISTANCE BETWEEN R WELL AND RNY ON-SITE SEWAGE DISPOSAL SYSTEM IS i00 FEET FOR R PRIVATE WELL OR i50 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM R PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS RND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PERI'-I I T E:~4P I RES DECEMBER Z-i.. -'!982 I CERTIFY THAT i: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE: 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS. V4. 0 & '*ENGINEERS, INC. 7125 OLD SEWARD HW~ ANCHORAGEt ALASKA 99503 349-6561 PERCOLATION TEST 5 13 -o- 14 FF O. 4~93 SOILS LOG - PERCOLATION TEST / ~3 15 16 17 18 19 2O COMMENTS PERFORMED BY: 72-008 (6/79) ~; If'/ Mo;~,,,. 7~ 0,.7. /WAS GROUND WATER ~1~ ENCOUNTERED? IF YES, AT WHAT SITE PLAN E. SWANSON 1834-E Reading Date PERCOLATION RATE Gross Net Depth to Net Time Time Water Drop TI~ST RUN BETWEEN ' ?' ,. FT AND' (minutes/inch) ?'/' FT '> ~--~-~ CERTIFIED ATE: