On-Site Water & Wastewater System Permit
OSPl11173
01701309000
WellSeptic
August 01,2011
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 EImore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to July 31, 2012
FLATTOP TECHNICAL SERVICES
T12N R3W SEC 25
T12N R3W SEC 25 S2SE4NE4SE4NW4 G:2840
CASSITY GLEN KEVIN
PO BOX 90354 ANCHORAGE AK 995090354
Site Mailing Address:
12940 MICHAEL RD, Anchorage
Lot Size in Sq Ft: 54450
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank
N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. d~ t 7
Property owner(s)
Mailing address
Site address
Day phone
Legal description (Sub'd., Block & Lot) .5 '2., _~ /.E '¢, N
Legal description (Township, Range & Section) -T' 12. I',/) ~'~
Lot Size Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR:
(1~ all that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
THIS APPLICATION IS AN:
Initial [~
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No. ~%~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 )
FLATTOP TECHNICAL SERVICES
CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS
TED MOORE, P.E.
PH./FAX: (907)345-1355
E-Mail: tgmoore~gci.net
July 24, 2011
14530 ECHO CANYON ROAD
ANCHORAGE, AK 99516
M.O.A. DSD
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for a
permit to install water supply and wastewater disposal facilities to serve a planned 3-bedroom residence
on S2, SE4, NE4, SE4, NW4, of Section 25, T12N, R3W, located at 12940 Michael Road. A site plan,
soils logs, design drawings and specifications and soils log are enclosed for your review.
Development of this property is complicated by the presence of an intermittent stream that traverses
roughly across the middle of the lot, leaving only limited areas that are greater than 100 feet from
surface water. To assess the feasibility of constructing wastewater disposal facilities on this property we
dug 3 test holes in May of 2009 at the locations shown on the site plan, and monitored groundwater
levels in each throughout the spring, summer and fall seasons. Test hole #2 proved to have the most
optimum soil conditions with clean, dry gravelly sand extending between 1.5 and 8.0 feet below ground
level. This sand material percs slightly faster than 1 minute per inch. A seasonal high groundwater
level was observed at 9.0 feet below ground level. A second perc test (2a) was conducted on 10/23/09
approximately 30 feet east of TH#2 to prove up a somewhat larger useable septic area.
Due to the excellent percolation characteristics of the native sand, in combination with the limited
available area, we propose to base the design on a soil application rate of 1.2 gpd/sq, fi, which is
normally used for soils with perc rates between 1 and 5 minutes per inch. This application rate should
work equally well for this cleaner material, and the native sand should provide adequate filtration of the
effluent. The proposed design is for a 5-foot wide drainfield with 2.5 feet of sewer gravel under the
distribution pipe. Using 1.2 gpd/sq, fi./day, the length of a standard 5-foot wide drainfield for a 3
bedroom residence would be (3 x 150)/01.2/5 = 75 lineal feet. With 2.5 feet of gravel under the
distribution pipe, the length reduction factor (calculated per the wastewater ordinance) would be 0.6364
- giving a total required drainfield length of 48 feet.
A replacement site for an ATS system is shown on the site plan. The proposed system is not expected to
have any significant impact on present or future water supply and wastewater disposal systems serving
adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or
on drainage. Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
WELL ,-'" ....
, N2, SE4, NE4, SE4, NW4, Sec 25, T12N, R3W .'"'
R = 100' _:~ ,'"
" "' INSTALL '?'",,,//
..-~'~ ./" '~ ' 1250 GALLON-----, ! '".,~. /
SEPTIC /~/// STEP TANK ~
SYSTEM ./..:'~ / ................... - ...... \
.... '/'// ........... P";bP... \ ',,~ R',:lOO'
'"-< ......... -:-: .... ! , ............ ? ....... '..... "i.,?.,j! ',-.:
"'-,, :~ '~- /" ! '"'-., '"'-,. R = 100' ~-. '"', '"->,71 ",, '~ --~ /11
",, PROPOSED ../ / "-, % ..... ~, ",,
'"", 3-BEDROOM ........... t '~. '"",. .... ",~ /~,""", '"" ~'"'. '",
" ....... ~ ~ "-T H /-'TJ',..,
" H ' ' - t ', x .... r
'. OUSE · '-. '. ;", ....
" ', #3 " " : g ~ ~I~ i
\ ',, ............ ~------/ .......... ~ ..... ..,. ~ \ i',, '--::,,,, ~ > .........
', o ',, .......... ~ ~' ....... ~ ',.,.~ ~.' ',, '.,.~ ~, ...........
, i ..... ':',, \
R = 100 >i ""-.. ~ ', "--., '-' ' ...... ..
, FM. WELL i '""- ~_ \ \ X ~ '~- ..:<, ...... '\ ~\x~- .... ',,,, _} .............
: '-. ..~- \ ~ X'- ,' '...-" t.-~:.x--'.,-. '.~
/ ......... U) ~ TEMF;.-..' ~ '"~'-, ;/T.B::< ...... ~ ~....~',, ....... ::,, -
/ ............................. ::;:::,.,~.!~,C..AB~~i...~~ ~,x~ <?.: .....
/' DRAINFIELD w. 2.5 GRAVEL J ........ ~' .:~.: '".. ~ "7' ..... \
' ,/' and 1' FILTER SAND UNDER ............ :>-'-:':~' ~,:..'-.'::_.~,:'< P-T-~'--._:
.-'"' PERF.DISTRIBUTION PIPE .... ........ M ATRF:AM~'--. ___~ ':--~u~/'% ~~:~;'~'~;' #2a -
.... "8ITL FOR 15' REPLACEMENT TRENCH FOR ) '"'"-, F~ -'"',.,. ,T,~H~,,,'" ~\'~? .....
ADV TRTMT. SYST. SIZED @ 4.0 GPD/SQ. FT .// "'". ",,,~1 "'",,, "'",, i~ESM T."
ii ii % R-lO0'- / : i } >i ............ [i /
i LOT 1 ' /
i ENGL~ S/D .
.,, . ~..'%, -,-.-~ ~ '"....
~' ~r~'e' ".~'- ~A '"' S2, SE4, NE4, SE4, NW4, Section 25, T12N, R3W
: ~ O~;' ~ TH '.%~ ~ %.. PROPOSED WELL AND SEPTIC SYSTEM
: ~ .7 ,r+~-- ;~,. ~ ......
.. ......................... ~. ... SITE PLAN
~ ~.~/'.,X ..... ~-.~',z, ~. .......
~ ~__ · THEODORE F. MOORE .e ..~ ~ SEPTIC ......... FLATTOP TECI-I~CAL SERVICES 1 INCH = 50 FEET
: '~i~: :. CE - 3589. ; ~Jl~ AREA 14530 ECHO CANYON ROAD DRAWN BY TFM
- · - 7'Z,' /'" *~-
~,~,, .o r ~{.~ ~.aF ANCHORAGE, ALASKA 99516 JULY, 2011
~ 'e,,e,o ,~:~ NOTE: CONTOUR
~Tm~ofess~O~ INTERVAL = 4' NOTE: THIS IS NOT A SURVEYED PLAT.
-- : ~'~'t~'~;~' ALL LOCATIONS SHOVVN ARE APPROXIMATE.
4" D-3034
FROM HSE.
1250-GALLON
STEP TANK
(w. 8' RISER)
1.25" DIA. SCHED. 40
PVC OR HDPE
M.T. 5~4~
1.25" DIA. SCHED. 40 PVC DISTRIBUTION PIPE
w. 3/16" DIA. HOLES IN BOTTOM AT 18" O.C.
48/
PLAN VIEW
SCALE 1" = 10'
48-FOOT LONG x 5-FOOT WIDE
SOIL ABSORPTION DRAINFIELD
w. 2.5' GRAVEL & 1.0' FILTER SAND
UNDER DISTRIBUTION PIPE
~ OF
I ~ · ~EODORE F. MOORE
V~ %. CE-3589 .~
MOUND FINAL GRADE 6"+ --
4" DIA. M.T. ~.
FILTER FABRIC ~
1.25" DIA. SCHED. 40 PVC ~
w 3/16" HOLES IN BOTTOM
SPACED 18" O.C.
3' SOIL
COVER
6
2.8' SEWER GRAVEL
1.0' FILTER SAND
ORIGINAL GROUND
DRAINFIELD
CROSS-SECTION "A - A"
SCALE' 1" = $'
S2, SE4, NE4, SE4, NW4, Sec. 25, T12N, R3W
SEPTIC SYSTEM DESIGN
PLAN AND CROSS-SECTION
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, AK, 99516
SCALE: AS SHOWN
DRAWN BY: TFM
JULY, 2011
J TEST HOLE # 2
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: S1/2, SE.!/~LNEI/4, SEI/4,~V~/!J~, Sec. 25, TI~2N, R_3_W,_~,M.
DATE PERFORMED: May 2Z~ 2_0__0.9 ........................
PERFORMED FOR: Kevi_n_Qa_s~sity ..................
DEPTH --
Pt.
(feet)
SM Reddish sandy loam
4
SP Gravelly sand
5 Clean, dry
7
8
9
10
11
12
13
14--
1{5 -4
18-
10
20-
GM Silty gravel
Soft, few boulders
Seeps below 10'
SLOPE
SITE PLAN
.,. ",-., ".,. 81"..
'.. ",.. . \ ",~ 0
", '-, '. "~-, :3>
#2 ~' 29 ;"-., P.~'
T.H.~ 3~'~0 -~' --..... J
l':'' -:- ~i ........... ~;ock Net Time Percometer Net Drop
uate I,(eaolng
Hme (minutes) Reading (inches)
[ L ~1 12:51:3~ 1 ] 21 7/8 I 1/~
~2. ..... ~5_3_~1~ ...... : . _2.~. 7!8 ..... ~ 1~2 _
[ Add~ater 12:53:47 23 3/8
COMMENTS:
PERCOLATION RATE <1 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN__2.5_, ...... FT AND 3.0' _ FT
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~'-~__..~ ._ _ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: "~ / ~- ~' _~. _//. ...........
TEST HOLE # 2
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: $1/2. SEl/4, NEll4. SEl/4, NWl/4. Sec. 25, T12N, R3W, S.M.
DATE PERFORMED: May 27. 2009
PERFORMED FOR: Kevin Cassity
DEPTH __
Pt.
(feet)
1 SM Reddish sandy loam
3
4
SP Gravelly sand
5 Clean. dry
6
7
lO
11
GM Silty gravel
Soft, few boulders
Seeps below 10'
SLOPE
Depth to Groundwater Date
Seeps at 10' 5/27/09
9.0' 6/9/09
11.5' 7/7/O9
Monitor tube dry 10/23/09
3 LO I
SITE PLAN
16
Perc
Test
#2a
Date Reading Clock Net Time Percometer Net Drop
Time (minutes) Reading (inches)
10/23/0 9
5-aallon pre-soak 2:33:40 23
Dry 2:35:40 2 17 6"+
PERCOLATION RATE <<1 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN 3.5' FTAND 4.0' FT
COMMENTS:
PERFORMED BY FLA'I-FOP TECHNICAL SERVICES. I ~"~ ~'~.¢',,.~. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~',',~ /
TEST HOLE # 1 ·
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: S1/2_, SEll4, NEll4, SEl/4, NWl/4, Sec. 25, T12N, R3W, S.M.
DATE PERFORMED: [Ylla~v_2~ 2_0_0_9
PERFORMED FOR: Kevin Cassit,j_
DEPTH __
(feet)
1
5
6
7
8
9
10
11
15
16
17-
18
19--
20--
COMMENTS:
Pt and loam
SP/SM Slightly silty gravelly sand
Gray/black, dry
Few scattered lenses of ML
SLOPE
SITE PLAN
GM Silty gravel
w. cobbles
and boulders
Depth to Groundwater Date
5/27/09
6/9/09
_ None
M.T. dry
M.T. dry_
MT. dry
7 / 7J_0__9
10/23/09
B.Ho
Reading Clock Net Time Percometer Net Drop
Time (minutes) Reading (inches)
5-ga[l_o_o Presoak~ 12:04:30 23 3/8
#1 12:05:30 1 19 7/8 3 1/2
#2
#3
12:Q6.'3_0
12:07:00
0.5
_1_8____
I 7/8
PERCOLATION RATE <1
TEST RUN BETWEEN 3.0
5~ga!.Lo_n~ pr e_s_oak_e n ti~eJ y_ab_s_o~b_~L _wltbi n _3_m i~n u te~
(minutes/inch) PERC HOLE DIAMETER
FT AND 3~5 FT
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~'"-~/' ~.t CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7
TEST HOLE # 3
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
DEPTH
(feet)
1-~
2
3--
Aw
11
Sl/2, SEl/4, NEll4, SEl/4, NWl/4, _Sec. 25, T12N, R3W, S.M. _
M a~L~ 7_~?-~Q09
Kevin Cassity
Pt.
SM Reddish sandy loam
SP Somewhat silty
Sandy gravel
GM Silty gravel
Water encountered
SLOPE
Depth to Groundwater Date
10' 5/27/09
7=.2.5' 6/9/09
10.3' 7/7/~__
M.T. dry 10/23/09
SITE PLAN
Reading
12.~D r_eAQ a k
Start
#1
Add water
#2
Add water
Clock Net Time Percometer Net Drop
Time (minutes) Reading (inches)
27 1/2
12:19:20 23 1/8
12:20:20 1 1 3/8
12:20:40
2:.t5
_ 21 3-/4
23 3/8
23 3/8
1 _1_/2___
#3 12:23:15 I 21 7/8 1 1/2
PERCOLATION RATE <1 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETVVEEN 2.75 FT AND 3.25 FT
COMMENTS:
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~ '~'~"'~--.¢.'-.¢_.=.. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ f ~- ¢ //I
o~lattop TechnicalSem, ices
14530 Bclto Canyon Poad, And~orage, AK 99516
Phone (907) 345-1355
S %, SE %, NE %, SE %, NW %, Section 25, T12N, R3W
12940 Michael Road
Wastewater disposal system
Specifications
1.0 General:
1.1 The scope of the project consists of installing a 1250-gallon STEP tank that pumps effluent
into a 48-foot long by 5-foot wide soil absorption drainfield with 1.0 feet of filter sand and 2.5 feet
below the horizontal distribution pipe (2.8' total gravel).
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work
around any buffed utilities.
1.4 Unless agreed otherwise, the contractor shall be responsible for any tree clearing and
grubbing necessary to complete the project.
1.5 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.6 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, and seeding all areas disturbed by the construction.
1.7 Prior to the start of construction the property owner shall arrange for a professional land
surveyor to stake out the proposed well location 2 feet south of the north property line and 28 feet east
of the intermittent stream. The surveyor should confirm that this well site is at least 103 feet from the
septic tank standpipes on the lot to the north. Next~ the surveyor should set laths at approximatelF 25-
foot intervals in the vicinity of the proposed STEP tank and drainfield to delineate the l O0-foot
protective radius from the well and the l O0-foot offset from the intermittent stream-
2.0 STEP Tank:
2.1 A new 1250-gallon Municipally approved STEP tank shall be installed in the general
location shown on the site plan, with particular care taken to minimize disturbance of mature trees, and
to ensure that it is outside the 100 foot setback from the well and surface water.
2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings.
2.3 The discharge line from the septic tank shall be 1.25" diameter schedule 40 PVC or HDPE.
2.4 The contractor shall be responsible to obtain the necessary Municipal electric permit and
inspection, and shall provide a copy of the electrical inspector's report to the engineer overseeing the
construction of the wastewater disposal system.
2.5 The second compartment of the tank containing the lift pump mechanism shall be equipped
with a watertight, insulated manhole riser and cover extending a minimum of 6" above final grade with
positive surface drainage away from the manhole. The contractor shall be responsible for determining
the necessary length of the manhole riser. The anticipated riser length is approximately 8 feet.
2.6 The on, off, and alarm floats shall be set at the elevations specified by the lift station
supplier, and their proper operation shall be verified by the contractor.
3.0 Soil absorption drainfield:
3.1 The soil absorption system shall be constructed in the location shown on the site plan by
excavating a 48-foot long by 5-foot wide drainfield footprint to a depth of 6 feet below ground level.
3.2 The bottom of the excavation should be level. A total of 1.0 feet of washed ISF filter sand
shall be placed in the excavation and compacted by foot to bring the elevation up to 5.0 feet b.g.l.
3.3 A total of 2.8 feet of sewer gravel shall be placed on top of the sand with the distribution
pipe laid level such that the pipe invert is no less than 2.5 feet above the bottom of the sewer gravel.
The distribution pipe shall be 1.25" diameter schedule 40 PVC with 3/16" holes drilled in the bottom
atl 8 inch spacing.
3.4 Monitor tubes shall be of 4" diameter and installed in the locations shown on the design
drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel, prior to
backfill.
3.6 The backfill shall be mounded a minimum of 6 inches above original ground level.
3.7 The homeowner shall be responsible for arranging to have the site finish graded after the
backfill material has stabilized, and for placement of adequate seed to promote rapid revegetation.
4.0 Inspections:
4.1 A minimum of 5 engineering inspections will be required during the course of the project:
(1) initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it conforms with the soil test information, (3) after the filter sand has
been placed and compacted, (4) after the sewer gravel is in place and the distribution pipes have been
laid and connected up to the septic tank, but prior to placement of filter fabric, and (5) after rough
backfill and grading is complete. The septic tank installation inspection shall be in conjunction with one
of the other listed inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far
in advance to ensure the availability of the engineer.