Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 56T12N R3W c 33 6 018-192 -10 Permit Number: Tax Code Number: Work Type: Permit Effective Dates: Design Engineer: Subdivision: Site Legal Address: Owner/Address: Site Mailing Address: On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 OSPl11184 01819210000 WellSeptic Initial August 15, 2011 EBSC Engineering, LLC T12N R3W SEC 33 to August 14, 2012 T12N R3W SEC 33 LT 56 G:3034 HAKALA EDWARD L & MARY S 2901 CAPSTAN DR ANCHORAGE AK 995160000 14345 BUMPY RD, Anchorage Lot Size in Sq Ft: Total Bedrooms: 108900 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Permit includes slope waiver OSPl11209, allowing the drainfield to be 35 feet from a 40% maximum slope. Special Provisions: Inspections shall be in accordance with AMC 15.65.150. Received By: Issued By: Date: Date: P.O. Box 196650 4700 Elmore Road Anchoraqe, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 ,http://www.m uni.or.q/Onsite Development Services Department On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** WR#: OSPl11209 HA#: Permit: OSPl11184 PID#: 018-192-10 Legal Description: T12N R3W Sec33 Lot 56 Engineer: Edward Hakala Applicant: Edward & Mary Hakala Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the slope greater than 25% has been approved. The approved separation distance is 35 feet. This waiver approval applies to the existing absorption field to slope separation only. Any future. upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: =D=ai~: 8_/,~ Approved b ' ,~, N~am~ of Reviewer Rec#: 144750 Amount: $200.00 Date Paid: 8/812011 **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan Phone:907-343-7904 Fax:907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING ParcelI.D. ~.'i.; ~ ,- - ~' Property owner(s).. ~'k//~42~) ~W,~ /~A/'Ir'Z~ i~,4P--~ c4 Mailing address ~ o l ~ ;7-/1~ O~f,J~ Day phone Site address "~ L~ ,~ . .~,L~ .,.r~,.~i,. _ ~, ¢,,L - , Legal description (Sub'd., Block & Lot) "f--~l~ AJ /. ~'~? f/d, Legal description (Township, Range & Section) -~-(' 2 ,/U/ t' ~ Lot Size Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: ([~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Sin Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ~ ~ ~ Date of Payment:. "~- .~ ~--/// Rece~ptNumber: ¢ _~ :~ ¢/ ¢/ ~ Permit No. ~ ~ ~ -: Waiver Fees:. Date of Payment: Receipt Number: Waiver No. ~:'~ G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) August 8, 2011 ElO.19 EBSC Engineering LLC 11301 Olive Lane Anchorage, AK 99515 Phone: 907-222-1085 Fax: 907-222-5210 www. EBSCengineering.com Municipality of Anchorage, Development Service Department Building Safety Division On-Site Water & Wastewater Program 4700 EImore Road Anchorage AK 99519 PERMIT: 05Pl11184 Subject: Septic System Design, SLOPE WAIVER REQUEST T12N, R3W, Section 33, Lot 56 Mr. Jay Crewdson: I respectively request that the subject wastewater absorption field receive a waiver for slope distance. As shown on the design drawings, the FIVE-WIDE trench is located approximately 25-feet from a slope that exceeds 25%. Our interest is to keep the drainfield in the same location, thereby allowing a greater area for the future reserve. The waiver request is based on the following: · Based on the attached profile drawings, the treated wastewater will not surface if it percolates at 25% or more. · Downhill slope is on the same property Thank you for your consideration. If you have any questions, please contact me at 222-1085 Edward L. Hakala, P.E. Principal Civil Engineer Ej~ectively Building Sustainable Communities August 8, 2011 ElO.19 EBSC Engineering LLC 11301 Olive Lane Anchorage, AK 99515 Phone: 907-222-1085 Fax: 907-222-5210 www. EBSCengineering.com Municipality of Anchorage, Development Service Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road Anchorage AK 99519 PERMIT: 0SPl11184 Subject: Septic System Design, AMENDMENT T12N, R3W, Section 33, Lot 56 To whom it may concern: The proposed 4 bedroom house on this lot will be served by a private well and septic system. A test hole was dug on the property and percolation tests were performed. The water table was not encountered and was not recorded during the 7-day monitoring period beginning on 7/26/11. We are proposing that a 1250 gallon STEP tank and a FIVE-WIDE drainfield be installed on the property. Notes regarding the design are summarized as follows: 1. Soils: See the attached soil profile log which shows the soil classifications, groundwater monitoring, and percolation test results. Based on the field results, an application rate of 1.2 gallons/day/SF is recommended. 2. Five Wide design: a. Percolation Rate: 2 minutes/inch b. Proposed Application rate: 1.2 gallons/day/ft2 c. Number of Bedrooms:4 d. Design Flow: 600 gallons/day e. Absorption Area: 500 SF f. Total depth: 5 FT g. Effective depth: 3.0 FT h. Width:5 ft i. Reduction Factor: 0.58 j. Minimum Length: 58 ft k. Effective Absorption Area: 290 FT Surface Waters: there are no surface waters located within 100 feet of the proposed septic system. Topography: The drainfield will be located 50' from the cut bank to the east and approximately 25 feet northeast from a slope greater than 25%. A waiver request is included with this design submittal. If you have any questions, please contact me at 222-1085 S,~ rely, Edward L. Hakala, P.E. Principal Civil Engineer Ej~ectively Building Sustainable Communities R1 ~ ~ LOT ,~1 i ~ ~ Ti2N, R3W, SEC 33 .~ ~ RIO0. O0 \ m EXISTING LOT 40 LOT 55 ,~, ~ ' T12N, R3~ SEC 33 , ~ ~ ~~ ~ ~ T12N ~3~ SEC 33~ ~ I~, /l~ ~ U~W~ ~ rococo ~, , ' '/ ~ /~/ 6 '~ ~, ~ EX~ST~NO' HOUSE ~ ~ T~2~, ~ S~C ~ -- WELL ~ I WELL ~ Rtoo.~o ' ~ ' ~ ~ ~ ~ R~OO. OO ~ ~,,~ / ~/ ~oo.~ ~ ~'V~o~ ~ ~~ ~,~ T12N, R3~ SEC ~/~.. ~oo so~ ~ HA~LA RESIDENCE ~P~oF¢o FO~ CONSr~UCr/O~ ~.~ ...... ~ .~ o, ~¢..~/¢/~o¢~ SEPTIC DESIGN ~9/-~:."' ' ..... ~~.~ o~, ~. ~o~ T12N R3W, SEC 33 ~ 49~~ ~ ~ W "~' ,,,,,,,,,,,, .... ,,, ,, ,,,,',,,,,~ CHECKED BX' aH LOT 56 ~" ..... ' ..................... '""~ ............ " ~EDWARD L. HAKALA ~.. ,,,:, oo, ~ ~ C '~;::~ ~ . .. ,, ~ ~ ....... ~ ~ ......'~? ~, ...- ~R/D NO.: S~0~5 ering e%?0FE%~~ SHEET NO.: I OF ~ i130~OLiVELN. ANOHO~GEAK, 99515 (907~222-1085 I ~ M T1 - I I SEPTIC ~ AREA , ~ ........ I ~/, I~ ~o~o~ ~/~.- ~o ~x~ ~x~ HA~LA RESIDENCE APPROVED FOR CONSfRUCflOfl ~ ~.. s/~/~o~ ~ SEPTIC DESIGN ~x~ ~x. ~. T~2N R3W, SEC 33 c,rcr~ ~x- r~, LOT 56 . O~/D NO... swsoz5 nglneenng SHEET NO.: 2 OF 4 1~3010LIVELN. ANCHORAGEAK, 99515 (907~ 222-1085 PERMITrlNG SU~URFACE DISPOSAL RELD A PERMIT MUST SE OBTAINED FROM THE MUNtCIPAU1'f OF ANCHORAGE, DEPARTMENT OF HEALTH AND HUMAN 1~, WIDE DRAINFIELD MUST BE INSTALLED PARALLEL TO THE SLOPE CONTOUR. SERVICES TO MODIFY, UPGRADE OR INSTALL AN ON-SITE WASTEWATER DISPOSAL SYSTEM.~. WIDE ORAINFIELD NOT TO 8E INSTALLED ON A SLOPE GREATER THAN TWENTY--FIVE (25) PERCENT· 1~VO ~NSPECTIONS ARE REQUIRED BY A REGISTERED C~qL ENGINEER 5, SINGLE DRNNRELD LENGTH ONCLUD~NO LATERALS AND EXq'ENSIONS) SHALL NOT EXCEED ONE HUNDRED (100) PEET, l, WHEN ALL EXCAVATING iS COMPLETE. 4, GRAVEL DEPTH BELOW PIPE MUST 8E NO MORE THAN FORTY--EIGHT (48) INCHES. 2. WHEN THE SEPTIC TANK IS INSTALLED AND THE 5~TEM IS READY TO 8E BACKFILLED. 5. GRAVEL DEPTH OVER PERFORATED PIPE MUST BE TWO (2) INCHES MINIMUM. SEPTIC TANK REQUIREMENTS ~i GRAVEL MUST 8E ONE--HALF (1/2) INCH TO TWO AND ONE-HALF (2 1//2) INCH SCREENED. 1, MUNICIPAUTY OF ANCHORAGE APPROVED. TWO COMPARRAENTS - INSTALL LEVEL. WITH A MINIMUM VOLUME 98' WiDE DRAINFIELO BOTTOM MUST BE LEVEL THROUGHOUT THE ENTIRE LENGTH, OF 1000 GALLONS PLUS 250 GALLONS FOR EACH BEDROOM OVER B. GRAVEL MUST BE DISTRIBUTED UNIFORMLY THROUGHOUT THE WIDE DRAINFIELO. 2. WATERTIGHT COUPUNGS ON INLET AND OUTLET. . PERFORATED PIPE MUST BE iNSTALLED LEVEL WfrH PERFORATIONS DOWN. 5. MANHOLES MUST BE EQUIPPED WITH WATERTIGHT CASKETS, I0. SiLT BATTLER MATERIAL MUST BE INSTALLED ABOVE THE FINAL GRAVEL LA~ER AND BELOW THE NATIVE SOL 4. FIVE (5) FEET MINIMUM UNDIS*nJRBED SOIL 8E-RNEEN THE TANK AND TRENCH, AND THE TANK AND BACKFILL. INSULATION BATERIAL WILL SERVE AS A SiLT BARRIER. FOUNDATION. 11. SMEARED WIDE DRNNFIELD SIDEWALLS AND SOl,OM MUST BE RAKED OR SCARAFIED BEFORE GRAVEL PLACEMENT. 5. TANK MUST SE iNSULATED IF BURIED FOUR (4) FEET OR LESS. · TANK AND SOLID PIPE MUST BE SET ON WELL COMPACTEO, STABLE SOIL. 12. INSULATION MUST 8E INSTALLED WHEN ~ACKFILL DEPTH iS LESS THAN THIRTY--SIX (36) INCHES. FOUR (4) INCH DIAMETER WITH AIRTIGHT CAPS ABE REQUIRED: 15. RACKIFLL OVER FINAL GRAVEL LAYER MUST NOT BE LESS TF~N TWENTY--FOUR (24) INCHES. ONE (1) TO FOUR (4) FEET FROM FOUNDATION WALL: AND 14, THE FINISH GRADE OVER AN ABSORPTION RELD MUST BE MOUNDED TO PREVENT THE FORMATION OF A 7B) PRIOR TO ANY PRE-TANK NINES' DEGREE 8ENDS IN 4--INCH LINE, AND DEPRESSION AFTER SE'C[1JNG. C) IN BACH TANK COMPARTMENT; AND 15. A WIDE DRNNRELD MAY NOT BE INSTALLED IN SOIL HAVING A PERCOLA~ON RA~ FASTER THAN ONE MINUTE PER INCH WITHOUT A Bl~ ANALYSIS SHOWING F~F~h'-ONE (51) PERCENT OR MORE PASSING D) TWO ADJACENT OPPOSING CL~ANOUTS BETWEEN THE TANK AND THE ABSORPTION FIEL~ NOT MORE TF~N ~4 SIEVE. I0 F~ FROM THE TANK POSITIONED TO PRO. DE CLEANOUT ACCESS TOWARGS THE TANK AND TOWARDS THE ABSORPTION FIELD. 16. INSULATION MUST BE PLACED OVER ANY PIPE INSTALLED UNDER ORIVEWAYS OR PARKING ANEAS 8. ALL CLEANOUTS MUST EXTEND TO AT LEAST GROUND LEVEL. ~7. THERE MUST BE A MINIMUM OF FOUR (4) FEET OF VERTICAL SEPARATION BE-PNEEN THE BO~TOM OF THE · IN SOL~D PIPE RUNS, ASTM D-3034 MAY 8E USED IN LIEU OF CAST IRON. WIDE DRAINFIELD AND THE SEASONALLY HIGH GROUNDWATER TABLE. 10. ALL PIPE CONNECTIONS MUST BE WATER TIGHT. 18. THERE MUST BE A MINIMUM OF SIX (6) FEET OF VERTICAL SEPARATION BETWEEN THE BOTTOM OF THE 11. TANK MUST BE CLEANED AND PUMPED AT LEAST ONCE EVERY TWO (2) YEARS OR INSPECTED TO WIDE DRAINFIELO AND ANY IMPERMEABLE BARRIER SUCH AS BEDROCK, FRACTURED OR WEATHERED DERERMINE THE NEED FOR CLEANING AND PUMPING AT LEAST ONCE EACH YEAR. BEDROCK. CLAY OR OTHER MATERIAL WITH A PERCOLA~ON RATE GREATER THAN 120 MINUTES PER INCH· 12. TANK MUST BE ~NSTALLED AT A SITE ACCESSIBLE Y~AR-ROUND TO A PUMPING TRUCK· THE ACCESS SmE FOR THE PUMP TRUCK MUST NOT BE FURTHER THAN ONE-HUNDRED (100) FEET FROM THE TANK AT AN ELEVATION NOT MORE THAN ELEVEN (11) FEET HIGHER THAN THE BOTTOM OF THE TANK. t _ 2. O0 MIN #:1SLOPES~t- TOPSOIL & SEED BoP- 2"fRIGID INSULATION `36" SEWER ROCK / '~ ~ 6" GRAVEL BELOW PIPE BOT-4 58' - 2. O0 MIN ~/- MONITOR TUBE EA. END ~NA TIVE BACKFILL BOP- 1 j ,36" SEWER ROCK / "-2" RIGID INSULATION BELOW PIPE ROT-4j 1~"~ PIPE W/ ~"HOLES ~ 18" O.C. ,DO .,,,-MONITOR TUBE EA. END x~NA TIVE BACKFILL BOP- 1 j '~_ ~ DC2~T1 -~LS~ FC ~ DC1~ ~ T2 OG I ~ DESIGN CRITERIA: 4 BEDROOM x 150 = 600 GPD ~ ROT SOILS = 600 GPD ~ 1.2 GPD~SF = 500 SF '~'"'-1250 GALLON STEP TANK (500 SF ~ 5 FT.) x 0.58 = 58 FT HA LA RESIDENCE APPROFED FOR CONST~UCflOfl SEPTIC DESIGN ..... T 2N R3W, SEC 33 , .............................. sr. LOT 56 ~EDWARD L ~KALA ~,0~ CE 10580 GRID NO.. SWJOJ5 ngineering SHEET NO.: Z OF ~ 1130~ OLIVELN. ANCHORAGEAK, 99515 (907)222.1085 L~ Z Z L~ Performed For: Legal Description: 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- '17- ~8- 20- Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchoraqe.ak.us (907) 343-7904 Soils Log - Percolation Test Edward Hakala Lot 56 Slope 6-12" Organics GP: brown poorly graded gravel w/ sand i N ~ I N E E R'S/B~5'~(--' ~ , 9TH ,'-..! D,,¢¢¢~'. No.10580 · '_~-,,~ / Date . Pe¢o~ed' 8/~2/~ Township, Range, Se~ion: T12N, R3W, Sec. 33, S.M. Site Plan WAS GROUND WATER ENCOUNTERED? NO S G M: gray silty IF YES, AT WHAT DEPTH? L O Depth to Water After P ~rave, Monitoring? NONE E Date: Reading Date Gross Time Net Time Depth to Water Net Drop 1 8/12/2011 9:45 5 7-9/16" 5-9/16" 2 8/12/2011 9:50 5 4-5/16" 2-5/16" 3 8/12/2011 10:00 5 4-15-16" 2-15/16" 4 8/12/2011 10:10 5 4-1/8" 2-1/8" 5 8/12/2011 10:20 10 7-3/4" 5-3/4" 6 8/12/2011 10:30 10 5-3/4" 3-3/4" 7 8/12/2011 10:40 10 5-11/16" 3-11/16" Bottom of hole PERCOLATION RATE 3 (minutes/inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 1 FT AND 2 FT COMMENTS Good soils, no water observed on 5/9/11, or on 7/26/11. No water after 7-days monitorina. PERFORMED BY: Edward Hakala I Edward Hakala CERTIFY THAT THIS TEST WAS. PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~¢~'//~./~! Percolation Test Supplemental Data Performed for Edward Hakala Lot 56 --T12N, R3W, Sec 33 S.M. Reading Date Gross Time Net Time Depth to Water Net Drop 8/12/2011 9:40 0 2" i 8/12/2011 9:45 5 7-9/16" 5-9/16" 8/12/2011 9:45 0 2" 2 8/12/2011 9:50 5 4-5/16" 2-5/16" 8/12/2011 9:55 10 7-15/16" 5-15/16" 8/12/2011 9:55 0 2" 3 8/12/2011 10:00 5 4-15/16" 2-15/16" 8/12/2011 10:05 0 2" 4 8/12/2011 10:10 5 4-1/8" 2-1/8" 8/12/2011 10:10 0 2" 8/12/2011 10:15 5 4-1/4" 2-1/4" 8/12/2011 10:20 10 7-3/4" 5-3/4" 5 8/12/2011 10:20 0 2" 8/12/2011 10:25 5 3-1/4" 1-1/4" 6 8/12/2011 10:30 10 5-3/4" 3-3/4" 8/12/2011 10:30 0 2" 8/12/2011 10:35 5 3-3/16" 1-3/16" 7 8/12/2011 10:40 10 5-11/16" 3-11/16"