On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP111307
Tax Code Number: 05133201000
Work Type: WellSeptic Initial
Permit Effective Dates: October 28, 2011
to October 27, 2012
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: FIRE LAKE
Site Legal Address: FIRE LAKE LT 1 TR A G:0554
Owner/Address: BILLMAN DAN B & PATTI E
HC 1 BOX 1706 GLENNALLEN AK 995880000
Site Mailing Address:
Lot Size in Sq Ft: 108900
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date: / c~ l~) d'" / //
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907- 343-7997
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. O~-~ J - ~ ~ ~
Property owner(s) DAN BILLMAN
Mailing address HC01 BOX 1706 * GLENNALLEN, AK 99588
Day phone 250-3117
Site address HC01 BOX 1706 * GLENNALLEN, AK 99588
Legal description (Sub'd, Block& Lot) FIRE LAKE S/D; TRACT A OF LOT 1
Legal description (Township, Section & Range)
Lot Size ] (~ ~, c/O(~ Sq. Ft. Number of Bedrooms 3
THIS APPLICATION IS FOR:
( [] all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy [~]
Private Well []
Water Storage r~
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
SI. OPE WAIVER AND LOT LINE FOR DRAINFIELD.
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number: (~_2~ / ~'~ (~
Permit No. ~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
October 21,2011
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650,
Anchorage, AK 99519-6650
(907) 343-7904
Ref: Well and Septic Design for Fire Lake Subdivision; Tract A of Lot 1
To whom it may concern:
Per the request of the owner, we have designed a proposed well location and septic
system for a 3 bedroom house. Several test holes were excavated on the property. The
proposed septic system will be designed around the 30 foot radii of test holes #5 and
#6. We are proposing that a 1000 gallon septic tank and a bed type drainfield be
installed. We are also proposing that a sewage pump station be installed for the garage
which is on a lower pad from the house. The pressurized line from the sewage pump
station to the septic tank may need to be placed is arctic pipe with heat trace due to
outcroppings of bedrock between the garage and house location that will restrict burial
depth. Comments regarding the proposed design are summarized as follows:
1. SOILS: Attached are the logs which show the soil classifications, groundwater
monitoring, and the percolation test results. The percolation rate for TH#5 and TH#6
were found to be faster than 1 minute/inch so a 2 foot sand filter will be required. An
application rate of 0.7 gallons/day/ft2 is required for a bed type drainfield with a sand
filter.
2. BED DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There is surface water (intermittent stream) south of the
proposed septic system. The septic system will be installed 100+ feet of any surface
water.
4. TOPOGRAPHY AND SLOPE WAIVER REQUEST: As can be seen on the attached
design drawing, the proposed drainfield is to be installed on a fairly flat area in a swale.
The general topography for the property runs southeast to northwest. We have attached
a cross section detail drawing (page 3 of 4) which shows a profile of the slope
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
conditions in the most crucial area. We are requesting a waiver from the drainfield to a
slope that is greater than 25 percent. As can be seen on the profile, at a 25 percent
slope 2 feet above the top of the drainrock (filter fabric) the slope does not daylight
within 50 feet. However, we are requesting a 23 foot waiver from the drainfield to slope
that that is greater than 25 percent. The following is mitigating factors for the issuance
of the waiver:
· Given the porosity of the soils, there should be minimal risk with lateral migration
of the effluent.
· The area below the drainfield is heavily vegetated.
Given these mitigating factors, there is minimal risk with the granting of this waiver.
5. LOT LINE WAIVER REQUEST: We are also requesting a 5 foot lot line waiver from
the proposed drainfield to the east lot line. In order to maximize the distance for the
drainfield to the steep slopes were are proposing that the drainfield be installed parallel
to the east lot line. The property to the east is Chugach State Park. We are unaware of
any adverse impact on the neighboring property with the granting of this waiver.
We are unaware of any adverse impacts this installation would have on adjacent wells
or septic systems. If you have any questions, please contact me at 337-6179. Thank
you for your assistance.
, P.E., M.S.
NOTE: Attached is a site plan drawing, a design drawing, detail drawings, soil logs, and
a 7 page construction specification letter which are all part of the design package for
this septic system.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
FIRE LAKE S/D
TRACT A OF LOT 1
GEG TH#f-,, DRAINFIELD~
SCALE:
, / ~ / J TRACT E OF LOT 1
GARNESS ENGINEERING GROUP, Ltd.
FIRE LAKE S/D, TRACT A AND TRACT C Of LOT 1 J L M ~3e,,._; I"-fS.."
_ o fesmO~_~
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEMS 10/18/2011 "~
GEG, Ltd. HAS A 7 PAGE SPECIFICATION
DESIGN CRITERIA (ALTERNATE): DESIGN CRITERIA (PRIMARY): LETTER THAT PEmAINS TO THIS DESIGN.
USING ADVANCED WASTEWATER SYSTEM NUMBER OF BEDROOMS: 5 TO OBTNN A COPY OF THE LE'I'I'ER
NUMBER OF BEDROOMS: 3 GALLONS PER DAY (GPD): 450 CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
GALLONS PER DAY (GPD): 450 PERCOLATION RATE/S: <1 MIN./INCH WELL DRILLER, CONTRACTOR AND
PERCOLATION RATE/S: <1 MIN./INCH PROPOSED APPUCATION RATE: 0.70 PROPERTY OWNER AGREE THAT THEY
PROPOSED APPLICATION RATE: 4.0 MINIMUM DRAINFIELD SQ.FT.: 645 HAVE READ THESE SPECIFICATIONS AND
MINIMUM DRNNFIELD SQ.FT.: 113 AGREE TO ACCEPT THE TERMS AND
DRAINFIELD DESIGN: CONDITIONS OUTLINED.
DRAINFIELD DESIGN: MAXIMUM DEPTH: 5 FEET ~
MAXIMUM DEPTH' 5 FEET WIDTH: 15 FEET ...~'""-
WIDTH: 5 FEET ' LENGTH: 45 FEET ~..~'~' ~
LENGTH: 25 FEET M.O.A. APPROVED SAND FILTER: 2 FEET , ~ ac
M.O.A. APPROVED SAND FILTER: 2 FEET EFFECTIVE: 0.50 ~
EFFECTIVE: 0.50 ACTUAL SQ.FT.: 675 ~ '~ /
ACTUAL SQ.FT.: 125 j~' ~.-~-.. SMALL CU~BANK~ /
.GTE: THE CO.TRACTOR SHALL HAVE ~ .~ /~ % / \ / ~ z~
THE EAST LOT UNE AND THE 100 FOOT -~ GEG THal,-~ ~/
SETBACK FROM THE STREAM FLAGGED .~" ~ '' /
BY A REGISTERED LAND SURVEYOR .~-~' / %. ~' / / ~ ? ! O,
PRIOR TO CONSTRUCTION. ~... xx ..-- ~r /- / /('
.-~"~ ' OLD TH '\ /SEE CROSS SECTION ~/ ~ '~ -~,~ ~ o~' o
/~ ~/ INSTALL DBL CO"--~ // ~ ¥~'~',.
..' GEG T.~ ,~ROPOSED ,000 GALLO. ,~ /.~ ~+
,~ OLD TH,I, -~ ./ SEPTIC TANK~ // X/.~' ,'~
~ ~.~ ~ ~ ,/THICK INSULATION // ~ \ /// , ~ ,/" '~.'~ I
JPROPO~ED 24'e PVC SEWAGE PUMP STATIO~-~ / UNDER DRIVEWAY.-~/x ~ \?' "~'~
/ I x~
,,' / L ~%~ / / /'~ ~?~ ~ ............ IL_J
.o~__ ........... _./i ~1oo1\
/ ' ~ / ! / o-g~-~~ / ........................ / I-"~ --cf-I DRAINFIELD
' ! ~ / / / ~ SITE. WILL REQUIRE / /~,
~ ~CED WASTEWATER SYSTEM-./ ~ (......'~".~.J
", PROPOSED ,* ,~' LINE. ~/ ~ ~ / ~ / 'GEG T.~51'.. '~.
x\ REQUIRE TO BE/SLEEVED IN / ~ .,I( / , ] 'xx '~'
'~.R..CTIC PIPE WIT~ HEAT TRACE. /.! I '"'..
'-. / I / f/ , ",,
'~.~. / / ~1 I ·
C '"' PROPOSED 100 FEET WELL RADIU~ ,., I '~I~,.
/ I ~ ,oo. s~4BAc~ "%,
\ 1' = 4o' /
\ \ I
\ /
PREPARED
FOR:
IPHONE
NUMBER: I PAGE NUMBER:',,x.z~.~ .l"//""/'""~";~':';";,' .....
DAN BILLMAN I 250-5117 I 2 OF 4 ~ '-)/ef*~y
LEGAL DESCRIPTION: ' ' DRAWN BY: ~,"{]h~]"../ CE-,795,~
FIRE LAKE S/D; TRACT A OF LOT 1 JLM
' ' ' \'~L'~&~' .......
DESlG~ or PROPOSED ~EUL A~D SEPTIC SYSTE~ ~012~{20~
~o ~o;~.' IP.o.~ .u.B~-.. I
D ' ~
~ ~c.,~o.: ~ ~ ~: k~/~~" _.~1
.- -~
FI.E ~KE S/D; TRACT A OF LOT 1 I ~'~'~'
~ o~ wo.~= '
c.oss s~c~o, to. s~o~ w~w..~u~s~
4' MONITORING TUBE-----~O
I
4" MONITORING TUBE.~I~.
4.5 FEET LONG
-i
MONITORING TUBE
4.' CLEANO
4." CL~OUT-~
4" MONITORING TUBE
t--FROM SEPTIC TANK
4-' MONITORING TUBE-
4' CLE. ANOUT--~ 4' CLEANOUT--~ 4' CLEANOUT--~ ~
4-" MONITORING TUBER \ \ \ \
o cow,
~ .............................. ~
0.5 ~ OF E~ECTIVE ~ .............. ~ ~ ~
· ~ ~ct~ FE~ OF ~OA APPROV[D ~N~ F~[E~%~:~,] I I
........ I 4'+ TO GROUNDWA~R~
" 10 ~L[~ W~UL '1 6'+ TO ~EDROCK
'T~~D &: ~EDED IN SPRING 2012.
GARNESS iENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
TUDOR RON), SUIIE 101 * ANCHORAGE., AN 99507 * F~ONE (g07)~37-6179 E, FAX (g07)538-3246 * t~tEBSI/E= m~m.gome~ettgineer~ng.com
PREPARED FOR: I PHONE NUMBER:
DAN BILLMAN I 250-5117
LEGAL DESCRIPTION:
FIRE LAKE S/D; TRACT A OF LOT 1
TYPE OF WORK:
DETAIL DRAWING OF DRAINFIELD
PAGE NUMBER:
40F4
IDRAWN BY:
J.L.M.
DATE:lO/18/201 1
A~ Gerness
CE-7953
CP-GW W/
MULTIPLE
LENSES OF
SAND AND
LARGE
BOULDERS
SW
SP
SM
SC
SW
SP
SM
SC
ORG
ML
CL
OL
HH
CH
OH
DEPTH TO
GROUNDWATER DATE
6' 10/14/11
5.5' 10/18/11
5.5' 10/21/11
SEE ATTACHED SITE PLAN
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
.... ,tx~.s
........ ~¢¢~
............... BB%0~¢B
PERCOLATION RATE *<1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES
TEST RUN BETWEEN 4 FT. AND 5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: []YES
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY:
COMMENTS: *REQUIRES SAND FILTER
[~] NO
JODY MAUS
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS)PER¢ORMED IN ACCORDANCE
WITHALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS' DATE:
GARNESS ENGINEERING GROUP, Ltd.
o Rs~.,cs TEST HOU
SM (LOAM
W/ROOTS)
GP-GW W/
MULTIPLE
LENSES OF
SAND AND
LARGE
BOULDERS
SOIL CLASSIFICATIONS
GW
GP
GM
GC
SW
SP
SM
SC
ORG
ML
CL
OL
MH
CH
OH
DEPTH TO DATE
GROUNDWATER
SEEP @ 10' 10/14./11
DRY TO 11' 10/18/11
DRY TO 11' 10/21/11
SEE ATTACHED SITE PLAN
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
.......... ~x~.S ...........
x~\x~s,, ~- ' ........
........ ,S ~0
¢.o~ "
~,~5o?'~p , ' ..........
PERCOLATION RATE *<1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES
TEST RUN BETWEEN 4 FT. AND 5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [--~YES
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY:
COMMENTS: *REQUIRES SAND FILTER
I~ NO
JODY MAUS
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS/ PEI~FORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~lOIZI
GARNESS ENGINEERING GROUP, Ltd '" '"& ~0
LEGAL DESCRIPTION: FIRE LAKE s/g; T~OT A OF LOT 1 ~~A, ~arnes~.-' ~ ~j
ORGANICS TEST HOLE ~lJ 'q~~
s~ (LOA~
W/ROOTS) SOIL C~SSIFIOATIONS
Gw w/
POCKETS
OF SW
POSSIBLE
BEDROCK
AT BOTTOM
OF HOLE
GW ~ ORG
GP ML
GM CL
GC OL
SW NH
__ SP CH
SM OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 9/29/11
DRY 9/30/11
DRY 10/6/11
SEE ATTACHED SITE PLAN
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
~.¢%% 5~,~ \" .......... "... '
~¢¢¢ xO ................
.......... ~o~CB ,,~ .................... '
,',' ...........
PERCOLATION RATE *<1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 4 FT. AND 5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: J--JYES
SOILS LOGGED BY: dODY MAUS PERCOLATION TEST PERFORMED BY:
COMMENTS: *REQUIRES SAND FILTER
J~NO
JODY MAUS
PERFORMED BY GEG, Ltd. I, JEFFREY a. GARNESS, CERTIFY THAT THIS WAS. PEF~FORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: IC)/ZI,/]1
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENE~ONT~CTORS r~
ITEST HOLE
BEDROCK JUST
BELOW SURFACE.
RIDGE OF
BEDROCK BETWEEN
PROPOSED HOUSE
LOCATION AND
TEST HOLE #1.
SOIL CLASSIFICATIONS
GW
GP
GM
GC
SW
SP
SM
SC
ORG
HL
CL
OL
HH
CH
OH
DEPTH TO
GROUNDWATER DATE
SEE ATTACHED SITE PLAN
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIHE (MINUTES) READING (INCHES)
NO PERCOLATION TEST - SHALLOW BEDROCK
PERCOLATION RATE - (MIN./INCH) PERC. HOLE DIA. - (INCHES
TEST RUN BETWEEN - FT. AND - FT.
A FOUR HOUR PRESOAK WAS PERFORHED: E]YES
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORHED BY:
COHHENTS: SITE UNSUITABLE FOR ONSITE SEP~C SYSTEM.
[] NO
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS ,PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I~/'Z,I/iI