HomeMy WebLinkAboutCHAPEL BY THE SEA TR 1Onsite File Chapel by the Sea Tract 1 PID# 018-242-16 Formerly Turnagain Park Tracts 3, 4 and 5 Sep_29.2022 10:54 AM Anchorage Well & Pump Service Inc 9072430742 #0877 P 1/ 1 MUNICIPALITY OF ANCHORAGE Development Services department Phone: 007-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: Date of Issue- Parcel Identification Number: 018.242 _ 1 Legal Description Block Lot Property Owner Name & Address: CHAPEL BY THE SEA INC CHAPEL BY THE SEA TR 1 14730 TURNAGAIN BLUFF WAY ANCHORAGE, AK 995595 Pump Installation Date:. 09 - 28 - 2022 Pump Intake Depth Below Top of Well Casing: 100 Pump Manufacturer's Name: RED JACKET Pump Model: O I l IPump ,Size: 1.50 hp feet Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name, MARTIN O N Pitless Adapter Installer:.. . Well Disinfected Upon Completion? X Yes 0 No Method of Disinfection, PELLETS Comments: Pump Installer Name: ANCHORAGE WELL & PUMP SERVICE Company: 7640 KING STREET ANCHORAGE, AK 99518 Mailing Address: 907-243-0740 City: State: Zip: T Attention: The pump installer shall provide a. pump installation log to On-site within 30 days of pump installation. Municipality of Anchorage Development Services Department Building Safety Division s • _* On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Pagel of 3 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: OSP111317 PID Number: 018.242-16 Noma'pel by the Sea Inc. Wastewater System: ❑ New ® Upgrade Address: 0 Tur a ain Bluff Way ABSORPTION FIELD Phone: Number of Bedrooms: ® Deep Trench D Shallow Trench ❑ Bed O Mound p Other: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 1.2 GPD/Ft? 12 Ft. Block Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: Tract 1 Chapel by the Sea 5.0 Ft. 7.0 FL Township: Range: Section: Fill added above original grade: Gravel Length: 0 Ft. 40 Ft. Well: El New F-1 Upgrade Gravel ddth: Number of lines: Distance between lines: 3 Ft. 1 Ft. Classification (Private, A, B, C): Total Depth:Cased to: Total absorption area: Pipe Material: ExistingClass'B' Ft. FL 560 Ft= 3034 PVC Driller: Date Drilled Static Water Level: Malabar: Date Installed: Ft. Beek's Contracting 111312011 Yield : Pump Set at: Casing Height Above Ground: TANK GPM FL Fl. SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublic[PnNate Manufacturer: Capacity: From Tank Field Station Tank Sever Line Anchorage Tank 2000 Gal. Well 214.8 218.0 50+ Material: Steel Number of Compartments: 2 Surf.. Water 100+ 100+ LIFT STATION Lot Line 76.6 65.6 Size: Manufacturer: Gal. Foundation 9 23.7 "Pump on° level at "Pump off' level at: High water alarm at: .6 in. in. in. Curtain Drain N/A N/A Pump Make &Model Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: Garage FF Assumed Elevation: 100.0 Ft. Engineer's Stamp Inspections performed by: PANNONE ENG. SVC, LLC Dates: tat 1113/2011 11/312011 OF q��S�11 Development 2nd IV���P�E : �•'' �i Services Department Approval i fie•49 �� �♦�I Conditional Approval Date: .....5,• r..•../ f/ •• ';Steven R.Pannone, i Reviewed and approved by: �� r ( Date: 0 -/-2,) % No. L 8149 �1'��I l.••' �ffzi (Rev. a4/06) ♦+, 11 \\\�•• i EXISTING SEPTIC AREA ilk +\ ,118.0/ "/121.5 8.6 F2 M2 \tea@ TH 214.8 WALL (E) 65.4/ 4" R.I. PARSONAGE 2" 0 HDPE F.M. / 7' DEEP �C , �. .- / \ GRINDER PUMP � IN BASEMENT CLIFF SIDE o� �< W CLASS 'B' WELL (E) r y G PRESERVE FIELD (P) 40LF x 3'W x 7'ED, 12'TD -PRIMARY FIELD (P) 4OLF x 3'W x 7'ED, 1 GARAGE 'po. "t20r iTi 008 SEPTICICTANK (P) WITH DOUBLE CLEAN OUT y� , PARKING LOT TR 1 \ ABANDONED EXISTING DRAIN FIELD IN PLACE —1250g SEPTIC TANK (E) \ ABANDONED PER CODE 77 SANCTUARY NOTES: RECORD DRAWING PANNON21 ENG SVC, LLC P.O. BOX 100217 ANCHORAGE, AK 99510 ��p,.• PHONE (907) 272-8218 FAX (907) 272-8211 /g,•' j*:49TM CHAPEL BY THE SEA, TRACT 1 CHAPEL BY THE SEA INC. S'te've'n'or CE 8149 14730 TURNAGAIN BLUFF WAY ft Qs .• PLAN ANCHORAGE, AK 99515 11/11/11 1t Scale P.I.D.NO _• / 018-242-16 j PERMIT NO. OSP111317 Sheet 2 OF A B T1 18.5 39.9 T2 12.6 27.3 DC 13.1 25.7 F1 28.6 46.9 M 1 27.6 45.8 F2 32.9 25.6 M2 30.3 25.0 i EXISTING SEPTIC AREA ilk +\ ,118.0/ "/121.5 8.6 F2 M2 \tea@ TH 214.8 WALL (E) 65.4/ 4" R.I. PARSONAGE 2" 0 HDPE F.M. / 7' DEEP �C , �. .- / \ GRINDER PUMP � IN BASEMENT CLIFF SIDE o� �< W CLASS 'B' WELL (E) r y G PRESERVE FIELD (P) 40LF x 3'W x 7'ED, 12'TD -PRIMARY FIELD (P) 4OLF x 3'W x 7'ED, 1 GARAGE 'po. "t20r iTi 008 SEPTICICTANK (P) WITH DOUBLE CLEAN OUT y� , PARKING LOT TR 1 \ ABANDONED EXISTING DRAIN FIELD IN PLACE —1250g SEPTIC TANK (E) \ ABANDONED PER CODE 77 SANCTUARY NOTES: RECORD DRAWING PANNON21 ENG SVC, LLC P.O. BOX 100217 ANCHORAGE, AK 99510 ��p,.• PHONE (907) 272-8218 FAX (907) 272-8211 /g,•' j*:49TM CHAPEL BY THE SEA, TRACT 1 CHAPEL BY THE SEA INC. S'te've'n'or CE 8149 14730 TURNAGAIN BLUFF WAY ft Qs .• PLAN ANCHORAGE, AK 99515 11/11/11 1t Scale P.I.D.NO _• / 018-242-16 j PERMIT NO. OSP111317 Sheet 2 OF SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK WAS IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. A. SCOPE OF WORK: INSTALLED NEW 2000 GALLON SEPTIC TANK, AND NEW SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS NOT OBSERVED TO A DEPTH OF 18' AS EVIDENCED BY THE SOIL TEST HOLE. AN APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE. 4" 0 DRAIN PIPE o ^ FILTER FABRIC TH-1 o DRAIN ROCK 6" ABOVE PIPE INVERT ML 5.0 , 0.5j_ ROCK GP/ GP INOWATER c� SECTION DIP DUCTILE IRON PIPE TH TEST HOLE ILII MONITORED FOUNDATION CLEAN OUT T# -18.0 80.5 0 0 w m0 w mm 5 Z o m x OFU o x p paU QZ J ¢¢yZ� Z W 2 L5 6 U J JU �Q OF EQ U 2" DIA PRESSURIZED II n.0 II -O4 n II II �4" 0 DRAIN PIPE UNE FROM HOUSE 2000g SEPTIC TANK DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 2000g PERC RATE = 1-5 MPI SOIL RATING: 1.2 GPD/SF AREA RQD: 500 SF SYS. TYPE: DEEP TRENCH 7' ED MIN LENGTH: 35.7LF PROFILE ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M# MONITOR TUBE NO. RI RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE USED: FS FLOW SPLITTER 40 LF X 3' WIDE, 7' E.D., 12' TD F FUTURE WITHIN 5 YEARS TOTAL AREA: 560 SF ( ) F.M. 2" FORCE MAIN NOTES: PANNONE ENG SVC, LLC 'ORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 CHAPEL BY THE SEA, TRACT 1 CHAPEL BY THE SEA INC. 14730 TURNAGAIN BLUFF WAY DESIGN DETAILS ANCHORAGE, AK 99515 LEGEND — W WATER LINE/ WELL RADIUS — SS — NEW SEPTIC FM 2" FORCE MAI nL,9��'9,�� /11 PIC *:*49 TH Scale P.I.D.TNO Steven R. cannon;* 8-242-16 IQ.. CE 8149 s PERMIT N0. OSP111317 r 111j��oFEs��P`��-= Sheet 3 OF 4 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSPl11317 01824216000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: November 01, 2011 to October 31, 2012 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: CHAPEL BY THE SEA Site Legal Address: CHAPEL BY THE SEATR 1 G:3033 Owner/Address: CHAPEL BY THE SEA INC 14730 TURNAGAIN BLUFF WAY ANCHORAGE AK 995154158 Site Mailing Address: 14716 TURNAGAIN BLUFF WAY, Anchorage Lot Size in Sq Ft: 145310 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ Issued By: ~Py~'~'t'U? .r~/",~.;/~/~P~'--? UNICIPALITY Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan R d S H! , ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 'Parcel I.D. OJ~' Property owner(s) 4LI~,~PEL ~'¢ 'l'//&' ,.,~E',,¢ 1,4/(--. Day phone Mailing address Site address } L~"'/6O Legal description (Sub'd., Block & Lot) C~//,o~/.. B'¢ 1"1.~c= ,.5~; .-.~_~,4~-r Legal description (Township, Range & Section) Lot Size I/.'/~ ,_~10 Sq. Ft. Number of Bedrooms OF ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 THIS APPLICATION IS FOR: THIS APPLICATION IS AN: ([] all that apply) Absorption Field ~. Initial [] Septic Tank [~ Upgrade [~ Holding Tank [] Renewal [] Privy [] Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single .Family Dwelling and is in accordance with applicable Municipal Codes. (Sigl~rt'u~:e ~{L er or authorized agent) / Permit/Rush Fees: ,.~5% ,/ %'~- Waiver Fees: Date of Payment: /C~/~% I \~ Date of Payment: Receipt Number: C,~,~"~ ,3/, ~'~ Receipt Number: Permit No. ~_~¢ \ \\ ,'~'~'-~ Waiver No. G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) Pannone Engineering Services LLC Steven R. Pannone, Principal Re§istered Professional En§ineer E-maih steve@panenRak.com October 27, 2011 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Chapel by the Sea, Tract 1 Septic System Permit Upgrade Request Ladies and Gentlemen: I am writing to request a permit to construct an upgraded septic system be issued for this property. The proposed systems will serve an existing four-bedroom house. Currently the lot is developed. The existing system is in failure, and is located within the well radius on the lot. I am proposing that we install a conventional wastewater system with a 2,000g septic tank to gain the extra retention time needed due to the grinder pump/lift station located in the house. The northern most residence on the lot is served by a private well. The 4-bedroom house that the upgraded septic system will serve and the other buildings on the lot are served by a class 'B' well (AK2215663). The adjacent lot is served by a private well. 1. Soils. A single test hole was excavated by Pannone Engineering Service in October of 2011. See the soil log attached. Ground water was monitored for seven days. No ground water was monitored to a depth of 18 feet below ground level after the monitoring period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 1.2 gallons/day/square feet should be used for a conventional system. Soil Absorption System Design. a. See Sheet 2 of the design package 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the existing drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The topography in the area generally slopes to the southwest at 2 to 4%. Mailina: P,O~ Box ::L00217~ Anchora6e, AK }951,0~,07.17 PhysicaJ: 61,5 East 82® Ave, Cuite B6~ Anchoras~% AK 99503 Telephone: (907) 272---82i8 FAX: (907) 272-8211 Page 2 of 2 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments Mai~ing: P,O, Bo)( 100227, Anchorage~ AK 9951G, 02!~ Physica: 6.i. 5 East 827d Ave, Suite B6, Anchorage, AK ¢}9503 Telephone: (907) 272~8218 FAX; (907) 272-821t · ~ '"~ WELL (E) · :, w~ ..', ~ ', + ' , 0 ..~ ~ OF AL~ ~ o/2~/~ ~ FOR CONSTRUCTION P,O, BOX 100217 ANCHORAGE, AK 99510 ~ ..... ';~ ~o~E (,0~) ~-8~8 ~x (,0~) ~-8~ ~&~;' ~:~t, so~,~ ~,..~~ '..,,~ ~"=8o' .. . ......... 018-242-16 ~-~-. ~ o~ .'z~ 14750 TURNAGAIN BLUFF WAY ~li ... Sh~e~ PLAN ANCHORAGE, AK 99515 ,~~ 1 OF 4 ~l/I -" W ~/~ ~ k ~RESERVE ,?ELD ~P) // ~ EXSTNG SEPTIC AREA-- ~'"',, / ~ ~ /~ ~ ~ ~~pRIMARy FIELDN(p)~ '~~ 2000g SEPTIC TANK (P)~1~ (E) 5.7 ,,F k .... ~ ~OL7~~ :B:N:ON :XlSTINO DRAIN FILD ,OTIS: P~O~ ~G ~C, L~ ~ , .~ Dote ~o~ co~s~c~,o~ 0.o. oox ~oo~z ,~c,o~,o~. ,~ ~o ~Zgg~.~ ~o~ ~ .'a~ ~ ~ '(~'~ ~"=¢o' CHAPEL BY THE SEA INC. 14750 TURNAGAIN BLUFF WAY ,¢~C~~9.C~ PERMIT NO. PLAN ANCHORAGE, AK 99515 ,I~0~¢[~ Sheet SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS} FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. .3. A. SCOPE OF WORK: INSTALL NEW 2000 GALLON SEPTIC TANK, AND NEW SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS NOT OBSERVED TO A DEPTH OF 18' AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. /--4" 0 DRAIN PIPE / /--F,LTER TH-1 ]//--DRAIN ROCK 6" ABOVE PIPE INVERT 5 7.0 ~ ~-DRAIN ROCK GP/ GP 6.0 SECTION NO WATER MONITORED o z z z ~-~ 2" DIA PRESSURIZED/--4" 0 DRAIN PIPE LINE FROM HOUSE _ _ 20009 SEPTIC TANK DEEP TRENCH - SEE DESIGN PROFILE DESIGN PARAMETERS ABBREVIATIONS CU COPPER PRIMARY/RESERVE SEPTIC SYSTEM DIP DUCTILE IRON PIPE LEG EN D NO. BEDROOM: 4 (600 gpd} TH TEST HOLE W WATER LINE/ TANK SIZE: 2000g PERC RATE = 1-5 MPI FC FOUNDATION CLEAN OUT WELL RADIUS SOIL RATING: 1.2 GPD/SF T# TANK CLEAN OUT NO. AREA RQD: 500 SF C# CLEAN OUT NO. $$ NEW SEPTIC SYS. TYPE: DEEP TRENCH 7' ED M# MONITOR TUBE NO· MIN LENGTH: .35.7LF R.I. RIGID INSULATION FM 2" FORCE MAIN DCO DOUBLE CLEAN OUT DV DIVERTER VALVE USE: FS FLOW SPLITTER 40 LF X .3' WIDE, 7' E.D., 12' TD F FUTURE (WITHIN 5 YEARS} TOTAL AREA: 560 SF F.M. 2" FORCE MAIN NOTES: PANNONE ENO SVC, LLC ~-~ OF Al --~ Dete FOR CONSTRUCTION p.O. BOX 100217 ANCHORAGE, AK 99510 . PHOHE (907) 272-8218 FAX (907) 272-8211 ff~o~.:." x,,O~:.'.-~a S¢ole ~ ..... P.I.D. NO CHAPEL BY THE SEA, TRACT 1 ~.~ "o~018-242-16 CHAPEL BY THE SEA INC. I~¢~.'.. CE 8149 ..~_~ PERMIT NO. TURNAGAIN LUFF' DESIGN DETAILS ANCHORAGE, AK 99515 li~,,r~;,~:~,-n'~:.~ Sheet ,%~,~-~.~-,~. ,3 OF 4 TH-1 SOILS LOG - PERCOLATION TEST SLOPE / /' SITE PLAN 2 -- ML BROWN SILTS 4--~ X 6 -- ~ -TH 9-- 10 -- POORLY GRADED 11 GP G~VEL W/SOME 13 -- WAS GROUND WATER SLOPE ~4 -- ENCOUNTERED? N ]5 -- IF YES, AT ~AT TH ~6 ~ DEPTH? -0-' X 17 ~ DEPTH TO WATER A~R MONITORING? --- ~ 8 DATE: 10/24/2011 BOH DATE PERFORMED: 10/14/11 READING DATE CLOCK WATER TIME NET TIME LEVEL NET DROP R~DING ~ 10/14/11 8:35 5.79 2 8:42 10 MIN 11.91 6.12 (D) 3 8:43 5.79 4 8:50 10 MIN 11.91 6.12 (D) 5 8:51 5.79 - 6 8:58 10 MIN 11.91 6.12 (D) PEROLATION ~TE 1.15 (rain/inch) PERC HOLE DIAMETER 6 inches TEST RUN BE~EEN 6 ~AND 7 COMM~N~S: Test ho~e excavated by B~'S ~O~M~D ~: Steve~ ~. ~o~e, ~.~. ~ CER~I~ T~AT ~IS ~S~ WAS ~O~M~D IN ACCO~DANC~ WI~ A~ STA~ AND ~UNICI~A~ OUI~IN~S IN ~C~ ON T~ DA~ O~ ~HIS T~S~. NOTES: P~O~ P.O. BOX 100217 ANCHORAGE, AK 99510 FOR CONSTRUCTION ~0/28/~ PHONE (907) 272-8218 FAX (907) 272-8211 W"~ ~ '~ NTS .... CHAPEL BY THE SEA, TRACT 1 ~ 018-242-16 147~0 TURNAGAIN ~LUFF WAY ii ~.. .~ OSPl11~17 SOILS LOG ANCHORAGE, AK 99515 :~" ...... '~ WATER READING DATE CLOCK TIME NET TIME LEVEL NET DROP READING 1 10/14/11 8:35 5.79 2 8:42 10 MIN 11.91 6.12 (D) 3 8:43 5.79 4 8:50 10 MIN 11.91 6.12 (D) 5 8:51 5.79 - 6 8:58 10 MIN 11.91 6.12 (D) TH-1 SOILS LOG - PERCOLATION TEST 2 -- ML BROWN SILTS 3 4 X 6 ~ ~TH ~ 0 ~ ~OORkY GP/ SAND 11 ~ GP G~VEL W/SOME .~'' 13 WAS GROUND WATER SLOPE 14 -- i ENCOUNTERED? N ~ 5 -- IF YES, AT WHAT TH 16 -- DEPTH? -0-' X 17 ~ DEPTH TO WATER A~ER MONITORING? --- 18 DATE: 10/24/2011 BOH DATE PERFORMED: 10/14/11 R~DING DATE CLOCK WATER TIME NET TIME LEVEL NET DROP READING 2 8:42 ~ 10MIN 11.91 6.12(D) 3 8:43 5.79 4 8:50 10 MIN 11.91 6.12 (D) 5 8:51 5.79 6 8:58 10 MIN 11.91 6.12 (D) PERO~TION ~TE 1.15 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BE~EEN 6 ~AND 7 FT COMMENTS: Test hole excavated by BEEK'S CONTACTING. PERFORMED BY: Steven R. P~none, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. REVIEwNOTES:oNLY P~O~ ~Gf. 10/26/11 MoA P.0. BOX 100217 ANCHORAGE, AK 99510 XXXXXXXXX READING DATE CLOCK WATER TIME NET TIME LEVEL NET DROP READING ~ 10/14/11 8:35 5.79 2 8:42 10 MIN 11.91 6.12 (D) 3 8:43 5.79 4 8:50 10 MIN 11.91 6.12 (D) 5 8:51 5.79 6 8:58 10 MIN 11.91 6.12 (D) Municipality of Anchorage Page .._.[_--of .. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~tJqZ. O'3,1~, PIDNumber: °I~ Name: Wastewater System: E~New I-I Upgrade ~-,,: ABSORPTION FIELD Phone: No, of S~ms; ~eepTrench D Shallow Trench D Bed D Mound D Other Total ~pth from original grade: Gravel length: WELl-: New Upgrade SEPARATION DISTANCES ~eptic a Holding a S.T.E.P. s~,.~. ~ LI ET STATION. Foundation I ~ O I q ~-- Cumin Drain BENCH MARK Remarks: ~NGINEE~EAL Inspections Pedormed by: [ - ~ Dates: ls~ Department of Health a~d Human Se~ices approval ~t{".. ........ '" .x30 0 30 SCALE, 6O 1' = 60 FT. IOBBEN 5PURKLAND P.E, 203 ~ 15TH. AVENUE ANCH. AK. 99501 TRACT $ ~LO0( I TURNAGAIN PARK SEr' ~ TIc*~V R3V CHAPEL ~ THE 2E~ IN~ SEPTIC SYSTEM ASDUILT DATE, ~EC. 11, 199P SHEET, 3/3 GRID, 3033 J Monitor 4olNCH PERF . ~ Cleon Ou~ Stondord Trench: 53' LONG TOTAL 15' £EEP 5' DF SEVER £0CK 1250 GAL T~NK I0 ~. Hira Fi 140 5 £eet; OF sept;lC Rock . . Cleonou~$ _ ?5.f A!o Voter, No Bedrock [x~$t Ground 9 £~ Cover 87.42 TnBBEN SPURKLAND P,£. 203 ~/15TH. AVENUE AK. 99501 TRACT 5 BLOCK I TURNAGAIN PARK SECTION 22 TI2N R3~/ The lnc ~^T£, ~EC. IL 1992 ~;HEET, 3/3 GRID, 3133 PAGE I OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 'L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920313 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:CHAPEL BY THE SEA INC OWNER ADDRESS:14730 SEWARD HIGHWAY ANCHORAGE, AK 99515 DATE ISSUED: 9/29/92 EXPIRATION DATE: 9/29/93 PARCEL ID:01824209 LEGAL DESCRIPTION: TURNAGAIN PARK BLK 1 TR 5 LOT SIZE: 48458 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DURING CONSTRUCTION, A TEST HOLE MUST BE DUG TO AT LEAST 21 FEET TO CONFIRM THE ABSENCE OF BEDROCK. THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH THE APPROVED ENGINEER'S DESIGN DATED 090392. ~ ?,.~ RECEIV'ED BY: ~? ~_~,~~~ DATE: ISSUED BY: ~~~ - DATE: TRACT At~CHOR~E, ALASKA 9950i (907) 279-19~ SEPTIC SYSTE~ BLOCE · TURN~G~ I N CHAPEL BY THE SEA, INC. PARK No Ground Water er Impervious Layer to 19 ft. Llse Standard Trench Soil Rating. From test Duly 28, 1992 < 1 min/in = 1.2 gal/min Filter layer not required. See design comments and sieve analysis. Required Area per Bedroom: 150/1.2 = 125 sq.ft.. Tank inlet 9 feet below ground surface. 8 feet of cover on tank. Locate drainpipe 10 feet below ground. Use 5 feet of rock. Verify no bedrock during installation Number of Bedrooms 4 Present System designed for 5 Replacement site required Lengtl~ of Trench 125 x 4 / 10 = 50 ft. Existing tank 1000 gal Not large enough for 4 bedrooms Replace with 10 gage 1250 gal tank. SYSTEM CONFIGURATION STAN.A.D TRENCH TOTAL LENI3TH 50 FT. TOTAL WIDTH ~ FT. ~/ TOTAL DEPTH 15 FT'~ ~ RO~K DEPTH 5 FT. PUMP AND CRUSH EXISTING TANK .LEAVE EXISTING CONCRETE PIT PLACE Septic System Design Tract 5 Block 1, Turnagain Park on. 1 The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Pending and/or concentration of surface runoff will not rest~lt from this installation. The insitu material perc faster than 1 min. per inch. According to WASTE WATER REGULATIONS Chapter 15.65 AMC 15.65.060 C. 2. a sand filter must be installed onless the Engineer can show to the satisfaction o~ the Department that the submitted design will function in compliance with the intent of section 15.65.060. The insitu material is a poorly graded silty gravely sand that does not meet the gradation requirement for a filter sand. The purpose of the filter sand is to slow down the percolation rate and to insure filtration of the effluent. A absnrption pit was installed on this lot in 1972. At that time the house served was a two bedroom house. The soil report submitted in 1~72 as well as the soil log for the two adjoining lots show similar soil as the attached soil log. The absorption pit installed in 1~72 quit working in January 1~2. This year both the tank and the pit have been plumped several times. The fact that both the tank and the pit fill up after pumping shows that there in no broken pipes or blockages in the system. The cause of non performance is organic mat build up in the soil. The filter layer is installed in free draining soil to assure that this organic layer does develop. The demonstrated fact that the insitu material causes a a organic mat to form, shows that the intent of the code is being Septic System. Design Tract 5 Block 1, Turnagain Park po.2 Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LECAL DESCRIPTION: ~'V~,~ ,,~ ~V~ 1 2 3 4- 5- 6- 7 8 9 10 13- 14- 15 16 17 18 19-, 20- COMMENTS Township. Range. Section: TI ~t~/ 'J~.t'~//. SLOPE SITE 1>LAN · WAS GROUND WATER H ~) ENCOUNTERED? S IF YES, AT WHAT ~) DEPTH? P E Depth, Water After,.. ~--)~ I--,.. Moflit~rino? ~ Dat~ Cross Net Depth to Net Reading Date Time Time Water Drop IJ PERCOLATION RATE ~, (m,nutes/inch) PERC HOLE DIAMETER · ~'~...~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. . 72-008 (Rev. TnBBEN SPURKLAN~q P.E. PO3 ~ 15TH. AVENUE ANCH. AK. 99501 TRACT 5 BLOCK I TURNAGAIIq PARK $£C 32 TI,2Y, R3V CHAPEL Sr rl~ ~A l~ SEPTIC SYST£H DESIGN DATE~ S'EPE ,~ 199~ SH£ET~ 1/3 GRII~ 3832 In Cle~%0 tlon Cle~n N 30 0 30 60 90 %, TBBBEN SPURKLAND P,E, 803 ~/ 15TH. AVENUE ANCH. AK. 99501 SEPTIC SYST£NI DE~ZGN /~ATD ST_.PT, ~4, l~ ~;I-I[£T, P,"3 GRIZ), 3033 DEPARTI',IENT OF EBiVIR0:,'r. IEr~TAL I~UALITYx 3§00 TURk'%ROAD ANCHORAGE, ALASKA 99507/w'~'\ ;686 INSPECTIO~ REPORT ON-SIT£ SEWAGE DISPOSAL Si'STEM SEPTIC TANK: / / DISTANCE FROM WEU ~;) LIQUID CAPACITY // ~ O ~) GALLONS. MATERIAL COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPlH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PHS / OUTSIDE DIAMETER OR WIDTH , DISTANCE FROM WELL / TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) LENGTH ,/~ , DEPTH . BUILDZNG FOUNDATION .3 ~ m. FT. , TILE DRAIN FIELD: DISTANCE FROM WELL ~ . NEAREST LOT LINE NUMBER OF LINES DISTANCE BETWEEN LINES '-"---'~"'""~ENC ABSORPTION AREA SQ. FT. JENGTH OF EACH LINE ~ DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE ~YPFT~ ~ ~ CI~ ~cll DEPTH ............. WATER ~ BUILDING FOUNDATION. S~PLE NEAREST SEPTIC SEEPAGE [O? [INE SEWER LINE TANK . SYSTEM CESSPOOl TOTAL LENGTH .. OF LINES. IN. TOTAL E~FECTIVE IN. ABOVE TILE .. NEAREST OTHER · SOURCES u¢ll GREATER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM ~. APPLICATION AND PERMIT O. /-/ "~,~,~'~'/~-"--- .A,L,.G A~O,ESS. ~.C,'%'. Z'/,~' Z)'.,.D.E ~?'~-~.r~ COMPLETION DATE A,~T,CIPATED //~/(/d. /~ 1972"" FINAL IN~PECTIONf E4 HOUR HOTIC~ REQUIRED. BACKFILLING OF ANY By~I'~M INrTHOL~T FINAL IN~E~ION BY THE MINIMUM DIITANCEB. REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TOJIEEPAOE PiT. T0 f~;e DRAIN FIELD TO NEAREST LOT LINE. WELL TO ISEP'TtC TANK _ ~"(~ /~ DIqA~N FIELD WATER MAIN TO SEPTIC TANK _ ].0 ft · O.AIN F,ELD X0 ALSO CONS~DEK ^.EA WELLS. SEEPAGE PiT ~0 ft. SE~T~CTANK. 25 ft.. SEEPA"S PiT ]00 ft. D.^tN FIELD__50 DA,~-.' ~-- '/- 1 g" A,PL,~A,T', ,'O"^T""E,~?~/4'44 ~ .~ ' 3500 TUDOR R(!AD ,A:JCHORAGE, ALASKA 99502 CASE Performed For '-'~¢ev,~r'- Date Performed 9-2? Leaal Descrintton:.~.~.~.~- Block / Subdivision Th~s Form Reoorts ~olls [~fl]....~ Perc-~tion Test qeoth Feet Soil Characteristics 5~ 6~ 7~ 9. Was Ground Water Encountered?.~o,_ If Yes, At what Depth? Reading Date !-q---I--J-! ~ ! I ,. L I : I , i I I i Percolation Rate qiqute Gross Time Net Time Depth to 1120 tlet Droni /' Proposed InstallaticT~-,': 5e~r,,,:)e Pit Pr(~i-. Field De~.th of Inlet____ P, enth l~-j~-o-~(;m Of Pit Or Trench. '' Cn~.'?ENTS: ~..~f/~. ~.ly,. __?_~:~,~"~~..~__re_~.~..~_- ~ ..~' .~::~,.___~'~/ /.~!'-'"""""""'~ Pa,ia Certifie,t Rv: Date: 0 -dR2D ~ MUNICIPALITY OF ANCHORAGE i~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PRC~TECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT =~[ DISTANCE'O: I~' length Of ,,nes~ Trench --idt ~inche ~[~ Top of tile to finish grade/~ Material benealh tile tO 0 /~inches Total., ,~t,. abso.ption ..ea OTHER 8OIL TEST RATINGI 2~ . , . ?2~O13IRev. 3/78) · OI'-I--S I TE PEF.']'IlT NO. ( 820~5 ) APPLICANT RLRSK8 ENVIRONMENTAL CO LOCRT I ON LEGAL I~,ll_ml'-I I ~ I pFIL I T%-" EmF AI'.IC:HORF~GE DEF'ARTMENT ~ HEALTH Ri'.IE:, ENVIRONMENTAL r'"~OTECTIODI ~ 825 ~- STREET, ANCHORAGE, RK. 9~_J£~ 264-4?20 SE~-IER PER,'1 I T 1220 H 25TH AVE. SUITE B 9950 TURNRGAIH PARK S?D TRACT 4 LOT SIZE 999999 SQURRE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MRXIMUM NUMBER OF BEDROOMS = -~ SOIL RRTIHG (SO FT/BR>= 125 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH= :i.E' LE~-IGTH= .o__4 GRA%.'EL DEPTH= THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DRAINFIELD. THE DEPTH OF 8 TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND 8ND THE BOTTOM OF THE EXCAVATION (IN FEET>. THERE I5 NO SET I.IIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE'MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE 8ND THE BOTTOM OF THE EXCAVATION <IN FEET>. ~:EQI_I I RED SEPT I C T~r~K S I ZE= ~g~B~ GRLLCmNS PERMIT BPF'LICANT HAS THE RESPONSIBILITY TO IHFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF 8NY HELLS ADJACENT TO THIS PROPERTY 8ND THE HUMBER OF RESIDENCES THAT THE HELL HILL SERVE. Tl,lO ( 2 > I [~SPEgT I O[W9 PRE REQL11 F:ED --1-- BRCKFILLIHG OF ANY ~YSTEH HITHOLIT FINAL IHSPECTION RND RF'PROYRL BY THI~ DEPARTMENT I.IILL BE SUBJECT TO PRO5ECUTZON. MINIMUD1 DISTANCE BETHEEN R HELL AND ANY ON-SITE ~EHRGE DZSPOSRL 5M~TE~ 1~ FEET FOR R PRIVATE HELL OR 15~ TO 2~ FEET FROH R PUBLIC HELL DEPENDING UPON THE T~PE OF PUBLIC HELL. HINIHUM DISTRDICE FROM R PRIVATE H~LL TO R PRZVRTE ~EHER LINE Z~ 25 FEET AND TO R COMD1UNITM SEWER LZNE I~ 75 FEET. OTHER REQUIREMEHT5 MR~ APPLY. SPECIFICATIONS AND CONSTRUCTION DIRGRRr'15 ARE RVRILRBLE TO INSURE PROPER INSTALLATION. PERr~ I T EXF' I RES DECEF'IBER gl. I CERTIFY THAT l: I RM FRHILIAR HITH THE REQUIREMENTS FOR ON-SITE SEHERS AND HELLS RS SET FORTH BY THE MUNICIPALITY OF RNCHORRGE. 2: I HILL IHSTRLL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE I5 REMODELED TO INCLUDE HORE THAN 3 BEDROOMS. V4. 0 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 2644720 SOILS LOG -- PERCOLATION TEST ,,~ SmLS LOO'- r-I PERCOLATION TEST PERFORMEDFOR: LEGALDESCRIPTION: 3 4- 5- 7 8 9 DATE PERFORMED:~ SLOPE SITE PLAN \ 10- 11 13 14 15 16. 17- 18- 19- 20- WAS GROUND WATER ~) ~. ENCOUNTERED? O P E IF YES. AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE {minutes/inch) TES. TRUN ETWEEN . FTAND , FT 72-008 (6/79} '_ GREAr-'', ANCHORAGE AREA 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE_SEWAGE DISPOSAL SYSTEM LOCATION -- SEPTIC TANK= DISTANCE FROM WELL INSIDE LENGTH MANUFACTURER INSIDE WIDTH MATERIAL LIQUID DEPTH NUMBER OF COMPARTMENTS LIQUID CAPACITY GALLON~ TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES. ABSORPTION AREA DEPTH= TOP OF TILE TO FINISH GRADE FOUNDATION DISTANCE BETWEEN LINES NEAREST LOT LINE TOTAL LENGTH OF LINES ,TRENCH WIDTH IN. TOTAL EFFECTIVE SQ. PT. LENGTH OF EACH LINE DEPTH OF FILTER MATERIAL BENEATH TILE .IN. ABOVE TILE IN. WELL= TYPE BUILDING FOUNDATION CESSPOOL APPROVED. CONSTRUCTION NEAREST , LOT LINE NEAREST SEWER LINE DEPTH SEPTIC SEEPAGE TANK ,, SYSTEM OTHER SOURCES DISAPPROVED. __REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL' LOT SLOPE: REMARKS= DIAGRAM OF SYSTEM DATE ~.~, APPROVED Form PW-027 GreaTeR ANCHOrAgE AReA bOrOUt~H PERMIT NO ~ SEE~AC~E PIT DRAIN FIELD ~ OTHER SOIL TEST RESULTS ~ NOel THIS PERMIT IS NOT VALID WITHOUT ~I~ SEWAGE DISPOSAL SYSTE/~ -- APPLICATION AND PE~./~...~_ SEPTIC TANK SIZE /~'~) TYPE SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, RE;QUIRI~ME;NT~ FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE ,