HomeMy WebLinkAboutDEARMOUN LT 15I)ea moun
Lot I
018-401
-02
Municipality of Anchorage
Community Development Department Page 1 of3
On-Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite • (907) 343-7904
ON-SITE WATER AND WASTEWATER INSPECTION REPORT
Permit Number: OSP111338 PID Number: 018-401-02
Name:
Jeff Carlstrom
WASTEWATER SYSTEM ❑ New ❑X Upgrade
ABSORPTION FIELD
❑ Deep Trench ❑X Shallow Trench ❑ Bed ❑ Mound
❑ other Dual 5-Wide
Address
13901 Ervin St, Anchorage, AK, 99516
Phone
907-562-5774
Number of Bedrooms
3
Soil Rating
0.8 GPD/SF
Total depth from original grade
10/10 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
7/7 Ft.
Gravel depth beneath pipe
3/3 Ft.
Subdivision
Dearmoun
Block Lot
15
Fill added above original grade
See dw . Ft.
Gravel length
2 33' 66 total Ft.
Township Range
- -
Section
-
Gravel width
5/5 Ft.
Beds: Number of LinesDistance
-
between lines
- Ft.
WfiJ,L (from logs/tests) ❑ New ❑ Upgrad
Classifica' Private, A, B, C)
Private (Exi )
Total Depth
Ca o
Ft.
Total absorption area
568+ Ft
Number of trenches
2
Dist. between trenches
10+ Ft.
Driller
Date Drilled Static Water Level
Ft.
TANK X❑ Septic ❑
S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1000 Gal.
Yield
GPM
Pumps Casing height above ground
Ft. Ft.
Matedal
Steel
Number of compartments
2
Water qualityto Coliform
Arsenic ug/L
Col/1
Nitrates mg/
LIFT STATION
Manufacturer
N/A
Capacity
Gal.
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
Lift Station Holding
Tank
Sewer
Line
Pump on level at
in.ii
Pump off level at
in.
High water alarm at
in.
Well
1001+
100'+
- -
25'+
Surface Water
100'+
100'+
- -
NA
Pump make and model
Electrical Inspections performed by
Lot Line
51+
101+
- -
Foundation
51+
101+
- -
PIPE MATERIAL D3034/F-810
Curtain Drain
NA
NA
NA NA
BENCH MARK Assumed elevation 100.00
Remarks:
Location and description
Top of flashing below siding, near FCO
Installer Wilco Contractors
Inspector GEG, Ltd.
Inspection 1-11/7/2011
dates:
2"° 11/8-9/2011
Engineer's Stamp
R Q,F
=y
"'" ""'
..........
r Ar erG rness,-'Q-�
7
.JOV
RaFESS
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
Approved Date S /
\\Gegl\gegfiles\ANCHO GE EA LOT 15\Inspection Report Form.doc
OSP -
NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER:
OSP111338 018-401-02
DEARMOUN LOT 14 /
'-
-I
/
I
A
B
C
/
FCO
14.39
9.73
26.35
/
\_
STI
87.76
77.22
88.60
_
ST2
93.58
82.87
194.0,31
NOTE: 100' WELL RADIUS WAS FLAGGED
NEW DRAINFIELDS
DBL1
95.54
84.77
95.87
PRIOR TO CONSTRUCTION BY REGISTERED
LAND SURVEYOR. 100' WELL TO DRAINFIELD
DBL2
96.19
85.43
196.43 1
SEPARATION VERIFIED DURING CONSTRUCTION.
FD
105.34
94.18
104.65
C01
107.24
97.65
109.13
CO3
\
CO2
124.87109.74116.45
5
CO2
MTI
124.26
109"62
116.74
��J
�;
° MTI
ALTERNATE SITE
I v
CO3
115.66
98.10
102.46
.11F"��' T2P /
I I WILL REQUIRE
�,�
ADVANCED TREATMENT
MT2
101.15
84.75
90.85
f
I n
C04
87.25
73.85
83.27
,OO 1 TH 1
I
I
m
C04
LJ
C01
C
m
I
NEW 1000 GALLON
m
B
SEPTIC TANK
EXISTING 3
° -
FCO i
-
BEDROOM
j
\
HOUSE
/
/
\
A / /
\
'•a
/ ° OLD
SEPTIC TANK AND \
CRIB
PUMPED, CRUSHED
/ AND ABANDONED IN PLACE
PER
CONTRACTOR \
DEARMOUN LOT 16
� I i
(-�SEPTIC
AREA
APPROXIMATE 100' WELL RADIUS
(SEE NOTE ON DESIGN)
GARNESS ENGINEERING GROUP, Ltd.
- CONSULTANTS & GENERAL CONTRACTORS --1 _. ,
5701 E WU 9080, SUOE 101 • MCHOWE, M 99W7 • PHONE (807).17-5IM • FM (907)79-3948 • Mmm- w .9om n8lna°Nn9.m
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
JEFF CARLSTROM 1 562-5774 1 2 OF 3
LEGAL DESCRIPTION: - DRAWN 6`
DEARMOUN S/D; LOT 15 1 A.J.G.
OF WORK: DATE:
AS -BUILT DRAWING OF NEW SEPTIC SYSTEM 1 12/19/2011
..... .......
A. arness.-
Pra
IPERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: I
OSP111338 018-401-02
TOP OF TANK
AT INLET = 93.94
INVERT OF BUNG
AT INLET - 93.48
EAST TRENCH
MT CO
ORIGINAL GRADE /
99.88
TH#1
NEW 1000 GALLON
SEPTIC TANK
FINAL GRADE =
101.45-101.95
FABRIC
ORIGINAL GR
= 99.77
- TOP OF TANK
AT OUTLET = 93.94
BUNG
= 93.31
WEST TRENCH
FINAL GRADE =
100.91-100.92
FABRIC
INVERT OF PIPE
F PIPE
.88 92.77
]• • OF BOTTOM OF
RELATIVETRENCH = 89.88 TRENCH - 89.77
• • I• RELATIVE•
F TESTHOLE = 83.77 (DRY)
GARNESS ENGINEERING GROUP, Ltd. per* : 4 T �I
CONSULTANTS& GENERAL CONTRACTORS p••.......• •• •...... .••••.•••
3701 E m R R . BURS 101 • M NOR90E, PN 99507 • PHONE (907)331-0179 • FM (907)330-3440 • WE959E: �nglnftmn rom
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0..... ••• . .... I ..........
JEFF CARLSTROM 562-5774 3 OF 3 of A. Gar ess.
.LEGAL DESCRIPTION: DRAWN BY: o0a CE- •0
DEARMOUN S/D; LOT 15 A.J.G. few ' •l'Ii �,rC !� c�v0
0 ey p�oo
TYPE OF WORK: DATE: 04O4p��or0fesslo�0o
PROFILE AS—BUILT DRAWING OF NEW SEPTIC SYSTEM 12/19/2011
On-Site Wastewater Disposal System Permit
Permit Number:
Tax Code Number:
Work Type:
OSPl11338
01840102000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: November 23, 2011 to November 22, 2012
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: DEARMOUN
Site LegalAddress: DEARMOUN LT 15 G:2935
Owner/Address: CARLSTROM JEFFREY P
910 CHUGACH WAY ANCHORAGE AK 995035637
Site Mailing Address: 13901 ERVIN RD, Anchorage
Lot Size in Sq Ft: 49500
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received I~: --
Issued By: g lr .- ,
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907- 343-7997
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D.
Property owner(s) JEFF CARLSTROM
Mailing address 13901 ERVIN STREET *ANCHORAGE, AK 99503
Day phone 562-5774
Site address 15901 ERVIN STREET *ANCHORAGE, AK 99505
Legal description (Sub'd, Block & Lot ) DEARMOUN LOT 15
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms
5
THIS APPLICATION IS FOR:
( [] all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS ,,,~ :, ,,,~;~:; ;,~: ~,: ~:~
November 8, 2011
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Septic Upgrade for DeArmoun Lot 15,
To whom it may concern:
The existing 3 bedroom house is served byan undocumented well and septic system. We are proposing to
abandon the undocumented septic system and install one of two options for a new septic system. The first
option is to install a new 1000 gallon septic tank and a dual 5-wide trench type drainfield. The second
option is to install a new 1000 gallon septic tank and a deep trench type drainfield. One test hole was
excavated on the property. The drainfields for both designs are designed around the 30 foot radius of this
test hole. Comments regarding the design are summarized as follows:
1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and the
percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system.
4. TOPOGRAPHY: As can be seen on the attached design drawing the topography around the
drainfield is relatively fiat. In short, there are no slope concerns.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems.
If you have any ions, please contact us at 337-6179. Thank you for your assistance.
U.S.
NOTE: Attached is a site plan drawing, a design drawing, one soil log, which are ail part of the design package for
this septic system. (Contact G. E.G. Ltd. for 7 page construction specification letter.)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.garnessengineering.com
DEARMOUN / / DEARMOUN ~ X 0
LOT 4 / LOT 1,3 X
----. / \ \
-.~ ! !
' ' ' ~' ~PTmC' ~ T12N. R~W, SEC
~ ~1 ~~ // AR~ ~ 27, LOT 52
LOT D~RMOUN 3 ~l '[ 'X ~, / / /
/ X x /
~RMOU~ X'.. /
X ~ LOT 14 ,//~ ~ WELL AND SEPTIC
- //~PTIC~ X ~ /' ~ ~ VSEPTIC ~ LOCATIONS ARE
~ ~ ~ ~ ~ ~ ~ AR~ UNKNOWN. FIELD
~ / AR~ ~ X VERI~.
o ~ ~ D~RMOUN I ~
~ ~ / ~ ' ~ LOT 15
X~ / ~ I
D~RMOUN ~1 / ~ X~
LOT 2 ~ / 1
/~ i~ ~ i~ w... A.~ s..~c
, /
_ ~ / / P~OPOSE~zSEPTIC- X I
D~RMOUN ~ D~RMOUN
LOT 1 / ~ ~ LOT 16 /
/ /
A HBUN
'
I ELMORE
I m BLOCK 1
FEJES I I LOT 1
LOT 2A I R3w,T12N. SEC
~ 1A33' LOT
1
SCALE: I
) mm I
. ...... ...
JEff CARLSTROM I s~2-s~I1 OF 2
LEGAL DESCRIPTION: DRAWN BY: ~%. ~ VCE779~5 ..' /~/
~PE OF WORK: DATE:
11/2/11
SITE
PLAN
DESIGN CRITERIA: / /
NUMBER OF BEDROOMS: ,.3 NOTE: THE CONTRACTOR / RESERVE DRAINFIELD DESIGN:
GALLONS PER DAY (GPD): 4-50 SHALL HAVE ALL WELL RADII MAXIMUM DEPTH: 10' MAX
PERCOLATION RATE/S: 7,5 --.. FLAGGED BY A REGISTERED WIDTH: 2.5'
PROPOSED APPLICATION RATE: 0.8 LAND SURVEYOR PRIOR TO LENGTH: 4-8'
MINIMUM DRAINFIELD SO.FT.: 565 CONSTRUCTION. M.O.A. APPROVED SAND FILTER: N/A
EFFECTIVE: 6.0'
DRAINFIELD DESIGN: × REDUCTION FACTOR: N/A
MAXIMUM DEPTH: 10' MAX DEARMOUN LOT 14 / / ACTUAL SQ.F[: 576
WIDTH: 5' / RESERVE SITE WILL REQUIRE
LENGTH: 2 @ ,35' =66' / A LIFTSTATION.
/
M,O,A, APPROVED SAND FILTER: N/A
REDUCTION FACTOR: 0.58
ACTUAL SQ.FT.: 568+ ~ ~'"~'- ~ ~
I
GEG, Ltd. HAS A 7 PAGE SPECIFICATION
LETTER THAT PERTAINS TO THIS DESIGN. ~ PROPOSED
TO OBTAIN A COPY OF THE LE'fTER ~ ~--DRAINFIELDS
CONTACT GEG. BY PROCEEDING FORWARD . /I
r RESERVE
SITE
WITH THIS INSTALLATION, THE ENGINEER, \ ~ I
I
WELL DRILLER, CONTRACTOR AND _ _,, C02/ 'CO~
PROPERTY OWNER AGREE THAT THEY ..~\~3.~~'~\ MT2~ MT4'~ mtI '~-
HAVE
READ THESE SPECIFICATIONS AND , ~'>~/' \ ~ ~ ~ II
CONDITIONS OUTLINED. ~00~>~ X ll II II
/%D,~O~O. ¢,~__~'~ GALLO~-~C TANK
~~_E_PZI_C.._T_ANK TO BE PUMPED,
~ / ENTED
DRAINFIELD TO BE
/ / ABANDONED IN PLACE.
/ / \
/ /
/ / \
% / / PER OWNER OF DEARMOUN LOT 16 THE WELL SERVING \
~ / ~' / THEIR PROPERTY IS LOCATED IN THE CEMENT PIT,
-'" ~--- ~ CONTRACTOR WILL BE REQUIRED TO STAKE 100' RADIUS
~S E~TI ~ FROM THE CLOSEST PO,NT OF THE P,T.
C
I RADIus
\ /
~ DEARMOUN LOT 16
SCALE:
40' CONSULTANTS & GENERAL CONTR, AOTOES
3701 E. TUDOR RO/~D, SUITE 101 ANCHORAGE, AK 99507 * PHONE (907)337-6179 * FAX (907)338-3246 * WEBSITE: ww~.gemessenglneering.com
JEFF CARLSTROM I 562-5774 2 OF 2
TYPE OF WORK: DATE: ~~
SEPTIC
SYSTEM UP GRADE DESIGN (OPTION 1) 11/2/11
'1 % '~"' .-
DESIGN CRITERIA: / /
NUMBER OF BEDROOMS: 3 NOTE: THE CONTRACTOR " RESERVE DRAINFIELD DESIGN:
GALLONS PER DAY (GPO): 4-50 SHALL HAVE ALL WELL RADII MAXIMUM DEPTH: 10' MAX
PERCOLATION RATE/S: 7.5 .--,. FLAGGED BY A REGISTERED WIDTH: 2.5'
PROPOSED APPLICATION RATE: 0.8 LAND SURVEYOR PRIOR TO LENGTH: 4-8'
MINIMUM DRAINFIELD SD.FT.: 56,3 CONSTRUCTION. M.O.A. APPROVED SAND FILTER: N/A
EFFECTIVE: 6.0'
DRAINFIELD DESIGN: / REDUCTION FACTOR: N/A
MAXIMUM DEPTH: 10' MAX DEARMOUN LOT 14- / / ACTUAL SD.FT.: 576
, WIDTH: 2.5'
LENGTH: 4-8' /
REDUCTION FACTOR: n/a ~ ,....--
I
ACTUAL SD.FT.: 576 ~ ~'"~-- ~ ~
I
GEG, Ltd. HaS A 7 PAGE SPECIFICATION
LETTER THAT PERTAINS TO THIS DESIGN. ~ PROPOSED
TO OBTAIN A COPY OF THE LETTER ~ ' f--DRAINFIELD
CONTACT GEG. BY PROCEEDING FORWARD . / r-RESERVE SITE
WltH..._T.H. IS_l,,l~T_A_LLATlON, THE ENGINEER, \ C02 ,/
Wh. ll UNILLLK, contractor AND . ~.x mt'J~l
PROPERTY OWNER AGREE THAT THEY .~\~3~/\ '"Il n'I
HAVE READ THESE SPECIFICATIONS AND _ ~.,'~" X II
CONDITIONS OUTLINED, f OO~/'" \ J l III
\ TH~,
ST1
/ ~V,~~" ? ~-'C i ~-PROPOSED %~
.... · : ..., .~ / ~
I
"~' ,~' / EXISTING UNDOCUMENTED
DRAINFIELD TO BE
/ / ABANDONED IN PLACE.
/ / \
/ /
/ \
/ / \
-.,,. / ,./ / PER OWNER OF DEARMOUN LOT 16 THE WELL SERVING \
~ /....~ ~-' ~ THEIR PROPERTY IS LOCATED IN THE CEMENT Pit.
'"'"--...._ CONTRACTOR WILL BE REQUIRED TO STAKE 100' RADIUS
EPTIFROM THE CLOSEST POINT OF THE PIT.
C
\ DEARMOUN LOT 16
\ I i/ SCALE:
:~?01 E. ~IDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 * PHONE (907)557-6179 * FAX (907)538-5246 * WEBSITE: www.gornesse¢lgineering.com
PREPARED FOR: I PHONE NUMBER: I PAGE NUMBER:
JEFF CARLSTROM I 562-5774 I 2 Of 2 ~'(/0~ ~ff/f~Y~' Go,ness...' ,~/
LEGAL DESCRIPTION: DRAWN BY: k~Oh~ "t/ CE-T~J
,I/'-. ,./_ _/_ .." -,,~/
DEARMOUN LOT 15 PNB
TyPE OF WORK: DATE- --~'~
SEPTIC SYSTEM UP GRADE DESIGN (OPTION 2) 11/2/11
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTFtJACTOR$
~ * WEBSI' game~nglnee~ng.com
CE-79 3 "
DATE'10/24/11
3701 E. TUDOR ROAD. SUITE 101 * ANCHORAGE. AN. 99507 * PHONE: (907)337-6179 * FAX: (907)358-3246 * WEBSITE:
[SOIL LOG - PERCOLATION TESTI
LEGAL DESCRIPTION: DEARMOUN LOT 15
PERFORMED FOR: JEFF CARLSTROM
ORGANICS [TEST HOLE #1 LOWER]
GW
GM TO ML
SOIL CLASSIFICATIONS
GP
GM
GC
SW
SP
SM
SC
ORG
ML
CL
OL
NH
CH
OH
DEPTH TO
GROUNDWATER DATE
DRY 10/24/11
DRY 11/1/11
SEE ATTACHED SITE PLAN
SCALE:
I I
1" = 100'
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
10/28/11 1 / - 6.00" -
2 / 30 2.00" 4.00"
3 / - 6.00" -
4/ 30 2.00" 4.00"
5 - 6.00" -
6 / 30 2.00" 4.00"
PERCOLATION RATE 7.5 (MIN./INCH) PERC. HOLE DIA. 6 (iNCHES
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY:
COMMENTS: PERCOLATION READINGS ARE TO CLOSEST 1/16 INCH
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS P~ERF~RMED
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
i'--I NO
ROB CAMPBELL
IN ACCORDANCE
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & :GENE~LA, L CONTRACTO:E~
3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AN. 99507 * PHONE: (907)337-6179 * FAX: (907)$$8-3246 * WEBSITE:
ISOIL LOG - PERCOLATION TESTI
LEGAL DESCRIPTION: DEARMOUN LOT 15
PERFORMED FOR: JEFF CARLSTROM DATE: 10/24/11
ORGANICS
GW
GM TO ML
ITEST HOLE #1 UPPER
SOIL CLASSIFICATIONS
GW ~ ORG
GP ML
GM CL
GC OL
SW MH
SP CH
sM OH SEE ATTACHED SITE PLAN
SC
DEPTH TO
GROUNDWATER DATE
DRY 10/24/11
DRY 11/1/11
SCALE:
I I
1" = 100'
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TINE (MINUTES) READING (INCHES)
10/28/11
ABSORBED 6" OF WATER IN LESS THAN A MINUTE - 4 TIMES
PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES
TEST RUN BETWEEN 1 FT. AND 2 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY:
COMMENTS: PERCOLATION READINGS ARE TO CLOSEST 1/16 INCH
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS I~ERI~ORMED
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
[~NO
ROB CAMPBELL
IN ACCORDANCE