Loading...
HomeMy WebLinkAboutCROSS VIEW ESTATES BLK 1 LT 9Cross View Estates Block 1 Lot 9 #015-301-57 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121004 Tax Code Number: 01530157000 Work Type: WellSeptic Initial Permit Effective Dates: January 20, 2012 to January 19, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: CROSS ViEW ESTATES Site LegalAddress: CROSS VIEW ESTATES BLK 1 LT 9 G:2737 Owner/Address: MCALLEN CHARLES & ANGELA 240 BOTANICAL CIRCLE ANCHORAGE AK 995150000 Site Mailing Address: 5201 HERITAGE HEIGHTS DR, Anchorage Lot Size in Sq Ft: 46686 Total Bedrooms: 5 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Ddnking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours pdor to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close 0n the same day. B. Covered, sealed, and heated to prevent freezing. ' ~,, Special Provisions: '~.. The Engineer needs to do an additional test hole prior to the construction of the septic field to ,~letermine the ground water level and if there is an impermiable layer. C~nstruction may;proceed .- a[yo,,r own dsk before the 7 day water monitoring is complete. Please submit stamped and : signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. ~ ' MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan Phone:907-343-7904 Fax:907-343-7997 ON-SITE SEWERNVELL PERMIT APPLICATION 0 57 100ur FoR A SINGLE FAMILY DWELLING Parcel I.D. 015-301-57 Property owner(s): Charles and Angela McAIlen Mailing address: 240 Botanical Circle Anchorage, AK 99515 Site address: Heritage Heights Drive Anchorage, AK 995t 6 Legal description (Sub'd., Block & Lot): Cross View Estates, Block 1, Lot 9 Legal description (Township, Range & Section) Lot Size: 46,686 Sq. Ft. Number of Bedrooms: Five (5) Day phone: THIS APPLICATION IS FOR: ([~ all that apply) Absorption Field X Septic Tank X Holding Tank [] Privy [] Private Well X Water Storage [] THIS APPLICATION IS AN: Initial X Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. '72,0 Waiver Fees: Date of Payment: Receipt Number: Waiver No. C:\Users~And E ng\Desktop~Permit Application.docC:\Users~AndEng\Desktop~Permit Application.doc I ANDERSON ENGINEERING PiOi BOX 240773 I ANCHO~GE, AK 99524 I $22.7773 67~7766 :(F~) I Janua~ 4,2012 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Block 1, Cross View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 9, Block 1, Cross View Estates Subdivision intends to construct a new five-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trenches and alternate site indicate silty sand with gravel (SM/ML). The percolation rate of the soil was determined to be 8 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .6 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500-gallon septic tank and 2-4-2~I~,~§ by 3' w;,J= by 7.5' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench.. ............ v the surface and the tot_~! ,2_~pth will b~ 11.5'. A flow splitter valve will be placed to insure even flow to each trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. Only one test hole was placed on the lot during the subdivision process. The City approved the subdivision based on the single hole to a depth of 16'. None of the test ~o~ t Lot 9, Block 1, Cross Point Estates Subdivision January 4, 2012 Page Two holes in the subdivision indicate the presence of bedrock nor do any of the logs of water wells placed to date..Both the primary absorption system and the alternate site fall within the 30' radius of the single test hole. The ground surface on the lot in the area of the septic system slopes to the northwest at a shallow grade with some cross sloping from the east. The new trenches will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ~..Y~~'""~ ...................... ....,....~ '~OFESS ~~ / TALUS DRIVE LOT 9 BLOCK 1 LILAC PARK LOT B VACAN% LOT 6 / VACA~ LOT 10 VACANT NOTE: No Areas of Excess'we Slope or Surface Water are Within 100' of Any Part of the New Septic System, CROSS PLAT NO. 2006-171 VIEW ESTATES SUBDIVISION LOT 9, BLOCK ~ 46,686 S.F. Five Bedroom Home LEGEND ' ~ - Monitor Tub. FCO- Foundation Cl~n Out ~6 - c,... out FSV - Flow 5pli~er Va~e THG - Test Hole Gomess SCAL£ 1' = 50' LOT 9, BLOCK 1, CROSS VIEW ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home 5' Wide Trench System Perc. Rate: 8 MinJInch 1,500 Gallon Septic Tank Application Rate: .6 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPDI.6GPD/SF (Application Rate) = 1,250 SF Absorption Area 1,250 SF/5 SF/LF*.5 (Red. Factor) = 125 LF Trench Length THEREFORE: Construct 2 - 63' Long x 5' Wide x 4' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Place Splitter Valve to Insure Even Flow to Each Trench. Natural Backfill Geotextile Fabric 4" Perforated PVC (Holes Down) ~. OF A Dra~nfield Rock ~ ~ · ,, .... TYPICAL DEEP TRENCH SECTION NOTE: (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From 'Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. h700 [ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT ELMORE ROAD ANCHORAGE, AK 99519-6650 DEPTH (feet) LEGAL DESCRIPTION: PERFORMED FOR: DATE:_ PARCEL ID#: SOILS LOG - PERCOLATION TEST LOT 9, BLOCK I, CROSS VIEW ESTATES SUB. CHARLIE ['¢ICALLEN 2 /2 3 4 5 6 GH 7 8 9 13 14 16 17 18 B OH 19 2O PROJECT No.: TECHNICIAN: SLOPE B. SCHILLER WAS GROUND WATER ENCOUNTERED? NO ,P.,'Es @ WHAT D¢'.~.__ DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITOPdNG: 1/24/12 Professional Engineers Stamp: SITE PLAN SEE SiTE PLAN DATE READING GROSS TIHE NET TIMEI %~HERT0INETpROP I (~'NUTES) I(mNUTES) I ('NCHES) IONcHEs) I TEST HO.E PRESO XED PR,OR T2, TESTING: 1/24 1 9:01/9:u 10 1.13/7.50" 6.37" 2 9:12/9:22 10 1.25"/7.50" 6.25" 3 9:23/9:33 r 10 1.25"/7.38" 6.13" I 4 9'34/9'44 10 1.13"/7.25" 6.12" 5 9:45/9:55 10 1. IY'/7.25" 6.12" 6 9:56/10:06 10 1.13"/7.25" 6.12" PERCOLATION RATE: 1.6 (MIN/INCH PERC. HOLE DIA. 6" aNChmS TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE:, 1/24/2012 ISOIL LOG - PERCOLATION T£STI LEGAL DESCRIPTION' HERITAO£ HILLS SUBDIVISION ~1; TRACT C&D (PROPOSED LOT 9> DEPTH ~ (feet> l~---:-,~i ORGANICS ITH#9/PTS#524 I i LOAM SOiL CLASSIFICATIONS ~:-~.~,~ GW ~ OR6  GM CL GC OL i oSW MH sc SITE PLAN DEPTH TO GROUNDWATER DATE DRY 8/31/2005 SM/ML DRY 19/19/2005 I lO I 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP . TIME (MINUTES) READING (INCHES) 12 9/2/05 1 2:00 6" - 2 2:30 30 1" 5" 13 5 2:30 6" - 4 3:00 30 1" 5" 14 i 5 3:00 6" - 6 3:30 30 1" 5" 15 16-~. 18 PERCOLATION RATE *6 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 5 FT. AND 6 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: [] YES [] NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: CALEB GALL COMMENTS: *RECOMMEND USING A 0.6 APPLICATION RATE PERFORMED BY GEG, Ltd. I. JEFFREY A. GARNESS. CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: /'('~)J,~] DEPTH TO GROUNDWATER DATE DRY 8/31/200~ DRY 9/19/2005