HomeMy WebLinkAboutPROSPECT HEIGHTS #4 BLK 2 LT 1Onsite File Prospect Hei*g s #4 x MOA has conf irmed that the upgrade has •z `'.' Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage, ak. us July 8, 1999 Gerald Stranik 2601 BONIFACE PKWY Anchorage, AK 995043144 Subject; PROSPECT HEIGHTS #4 BLK 2 LT 1 Permit # SW9803 I0 PID #'015-091-60 The subject permit, issued 8/18/98 by this office for a single family well and/or on-site wastewater system, is due to expire as of 8/18/99. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. However a new permit can be issuedJ?ee of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit for which a fee was paid. When applying for a new permit after the original permit has expired or for more than a secon, d year, the fees are.~$320.00 foran on-site wastewater permit and $120.00 for a well permm If you have any questions, please call this office at 343-4744. Program Manager On-site Services enc: Copy of Permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Aug 18, 1998 Expiration Date: Aug 18, 1999 Permit Number: SW9803~10 Legal Description: PROSPECT HEIGHTS ~4 BLK 2 LT 1 Design Engineer: 0014 Anderson Engineering Owner Name: Gerald Stranik Owner Address: 6600 Wes Way Anchorage, AK 99518- Parcel ID: 015-091-60 Site Address: Lot Size: 92023 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 (24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special previsions. This Permit is issued for the construction of an innovative Recireulating Trickling Upflow Filter system. As a condition of this permit,the owner shall make arrangements for the system to be sampled once a month for a maximum of 12 consecutive months .The attached property owner agreement becomes a part of this permit package. August 5, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 1, Block 2, Prospect Heights Subdivision No. 4 Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Block 2, Prospect Heights Subdivision No. 4 intends to construct a 4 bedroom home on the lot. We are therefore requesting a well and septic system permit be issued for the lot. The attached site plan and backup documentation identify the size and location of the new septic system and well proposed for the lot. It also shows the location of the 100' protective radius. Three testholes were placed on the lot at the locations shown. In all cases bedrock was encountered at depths between 5.5' and 6'. The material above the bedrock, however, percolates well and there is no evidence of groundwater. We are therefore proposing placement of a recirculating septic tank with an upflow filter. This system requires an absorption bed of 150 square feet based on a percolation rate less than 30 minutes per inch. We are designing a 300 square foot bed for additional capacity. Soil materials on the lot consist of peat and organic material for the initial 1' to 1.5'. This material is underlain be silty sand and gravel to depths of 5' and 6'. More than 2' of unsaturated percable soil is available for the absorption bed. Our design shows placement of the distribution piping at the ground surface. All organic material will be removed and replaced with coarse sand. The bottom of the bed will be a minimum of 4' to 5' above the bedrock layer. The surface of the lot slopes from east to west at varying grades. Lot 1; Block 2, Propsect Heights No. 4 August 5, 1998 Page Two The slope from the road is approximately 10%, but flattens out in the area of the absorption bed. The slope then increases to 15% to 20% to the west boundary of the lot. No conflicts will exist between the new system and wells or septic systems in the area. If the system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments \ THIS PROJECT AREA MAP SCALE 1"= 100' /"- I 1 / I' I I I I I ,/ / / / / / / / / / / / 15% - 20% / / / / / / / / // / / / / ~ Jo Proposed Well 10% SITE PLAN -- SCALE 1" = 50' I Jo -- ~2,000 Gallon Recirculating '~ _ Septic Tank Four Bedroom / ~ Upflow Filter Home /, ~ _ ~ Sample Basin Absorption Bed SYSTEM PLAN NO SCALE LOT 1, BLOCK 2, PROSPECT HEIGHTS SUBDIVISION, NO. 4 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: 7 MinJInch Application Rate: 4 GPD/SF Shallow Bed System 2,000 Gallon Recirculating Septic Tank with Upflow Filter 4 Bedrooms X 150 GPD = 600 Gallons Per Day 600 GPD/4.0 GPD/SF /15 LF Width -- 10 LF Total Length of Bed Therefore: Construct a Shallow Bed System 15' Wide X 20' Long. Distribution Piping to be Placed at Ground Surface. Mound Over Bed To Provide 3' of Cover or Provide 2" of Direct Bury Insulation and 2' of Cover. Replace Organic Material with Lake Otis Sand (Specification Attached). atural Backf / ~ 2" HI Direct Bury Insulation Remove Existing Organic Material Replace With Lake Otis Sand (See Attached Specification) 1 ' Drainfield Rock .5' 2.5' 5' 5' 2.5' NOTE: SHALLOW BED SECTION (NO SCALE) Grade Area to Drain Away. Maintain 4' Separation From Bedrock. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST f .. oo'.?:~ , PERFORMED FOR, Pamela Dahl DATE PERFOR~M~~ LEGAL DESCRIPTION: Lot 1, Block 2 r Pros- Township, Range, Sectiom '-, - - 1 2 3, 4- 5- 6 7 8 9, 10- 1I pect Heights, No. 4' SLOPE I3 14 15 16- 17- 18- 19- 20 COMMENTS WAS GROUND WATER SITE PLAN ENCOUNTERED? ,.'E,. A','W.A',' DEPTH? ~ None $'. ,.lo .~o 9:/I PERCOLATION RATE 7 T~ST RUN BETWEEN Test Cavity Presoaked Prior to Test. (minutes/~ncl3} PERC HOLE DIAMETER FT AND /'~ Fi' · ' '""'--~'~"'"'~ THAT/?HI$~'EST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ', ~/f'S'-/~ ~ 72-008 {Rev. 4/851 PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH '& HUMAN SERVICES 825 'L" S~ee~ Anchorage, AJaska 99502~650 SOILS LOG -- PERCOLATION TEST Pamela Dahl LEGAl. DESCRI~IO~: Lot 1 r Block 2 r Pros- Townshil~, Range. Section: pect Heights, No. 4' SLO,E 2 6, 7- ,,,J,,,o 8 9 10 WAS GROUND WATER 11- I2- 13- 14- 16 17- 18- . 2O COMMENTS F]ateri ~ 1 ENCOUNTERED? No E IF YE~. AT WHAT ~ DEPTH? p. None ~.. 8/5/qR Gro~ Ne~ Time Time ' Similar to Testhole No. PERCOLATION RATE tminute~,ncn; pER¢ HOLE DIAMETER TEb'T RUN BE'~VEEN FT AND FT 1 :ERFORMED SY. , ! ~~:~~HAT TH/S ~ WA~. P~RFORMED iN CCORDANCE WITH ALL STATS AND MI2NICJPAL GUIDELINES IN EFFECT ON THIS DAT[ DATE: . ~/~/¢~ 72~08 {Rev. 4/85) Mu~cJpality of Anchorage DEPARTMENT OF HEALTH '& HUMAN SERVICES 825 'L' stree~ Anchorage. AJaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR:.., Pamela Dahl LEGAL DESCRIFTION:,.Lot 1 r Block 2t ~ect Heights, No. 4 2 3 4, $- 6 7 8 9- 10 12 15 16 19 20 COMMENTS OATE PERFOF Pros- Township, Range, Sectiorc WAS GROUND WATE~ ENCOUNTERED? , NO IF Y;~. AT WHAT DEPTH? None Sl~ P~AN · , {minute~.mcll) PERC HOL~ DIAMETER ,, ~ ~ TEST RUN BETWEEN., J PT AND ~ FT Test Cavity Presoaked Prior to Test. ACCORDANCE %%1TH ALL STATE AND MUNICIPAL GUIDEL NE$ IN EFFECT ON THiS DATF-- OAT;' '-- ~)/~/¢~ ~ 72~08 (Rev. 4/S5) 0 RECIRCULATING LiFT STATION SEPTIC TANK WITH TRICKLING FI~.TER & UPFLOW FILTEil iNCflOr, iGE TiN[ i WELOHG, NC, 0 ,< ~AN K HEAD MANHOLE 7"¢ HUB HOLE IN BAFFLE W/6"¢ TANK 15 30" 80 MANHOLE HEAD ~NG L~FT STATION SEPTIC T.~NK wrr. TRICKLING FILTER RECIRCULATING LIFT STATION SEPTIC TANK WITH TRICKLING FILTER