July 8, 1999
Gerald Stranik
2601 BONIFACE PKWY
Anchorage, AK 995043144
Subject;
PROSPECT HEIGHTS #4 BLK 2 LT 1
Permit # SW9803 I0 PID #'015-091-60
The subject permit, issued 8/18/98 by this office for a single family well and/or on-site
wastewater system, is due to expire as of 8/18/99.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
If a licensed Professional Engineer has inspected the installation of the on-site wastewater
system, the original as-built inspection report must be sent to this office for review,
approval and documentation. All inspection reports must be submitted within 30 days of
construction completion.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date. However a new permit can be issuedJ?ee of
charge for a second year if the application for the renewal is received on or before the
date of expiration of the original permit for which a fee was paid.
When applying for a new permit after the original permit has expired or for more than a
secon, d year, the fees are.~$320.00 foran on-site wastewater permit and $120.00 for a well
permm
If you have any questions, please call this office at 343-4744.
Program Manager
On-site Services
enc: Copy of Permit
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Date Issued: Aug 18, 1998
Expiration Date: Aug 18, 1999
Permit Number: SW9803~10
Legal Description: PROSPECT HEIGHTS ~4 BLK 2 LT 1
Design Engineer: 0014 Anderson Engineering
Owner Name: Gerald Stranik
Owner Address: 6600 Wes Way
Anchorage, AK 99518-
Parcel ID: 015-091-60
Site Address:
Lot Size: 92023 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 (24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special previsions.
This Permit is issued for the construction of an innovative Recireulating Trickling Upflow Filter system. As a
condition of this permit,the owner shall make arrangements for the system to be sampled once a month for a
maximum of 12 consecutive months .The attached property owner agreement becomes a part of this permit
package.
August 5, 1998
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject:
Lot 1, Block 2, Prospect Heights Subdivision No. 4
Septic System Design
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 1, Block 2, Prospect Heights Subdivision No. 4 intends to
construct a 4 bedroom home on the lot. We are therefore requesting a well
and septic system permit be issued for the lot. The attached site plan and
backup documentation identify the size and location of the new septic
system and well proposed for the lot. It also shows the location of the
100' protective radius.
Three testholes were placed on the lot at the locations shown. In all
cases bedrock was encountered at depths between 5.5' and 6'. The
material above the bedrock, however, percolates well and there is no
evidence of groundwater. We are therefore proposing placement of a
recirculating septic tank with an upflow filter. This system requires an
absorption bed of 150 square feet based on a percolation rate less than 30
minutes per inch. We are designing a 300 square foot bed for additional
capacity.
Soil materials on the lot consist of peat and organic material for the
initial 1' to 1.5'. This material is underlain be silty sand and gravel to
depths of 5' and 6'. More than 2' of unsaturated percable soil is available
for the absorption bed. Our design shows placement of the distribution
piping at the ground surface. All organic material will be removed and
replaced with coarse sand. The bottom of the bed will be a minimum of 4'
to 5' above the bedrock layer.
The surface of the lot slopes from east to west at varying grades.
Lot 1; Block 2, Propsect Heights No. 4
August 5, 1998
Page Two
The
slope from the road is approximately 10%, but flattens out in the area of
the absorption bed. The slope then increases to 15% to 20% to the west
boundary of the lot. No conflicts will exist between the new system and
wells or septic systems in the area.
If the system is constructed as designed the following statements apply:
The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
The system, if constructed as designed, will have no adverse
impact on reserved space, either surface or subsurface, on any lots
located in the area.
The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern will
be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
\ THIS PROJECT
AREA MAP
SCALE 1"= 100'
/"-
I
1
/
I'
I
I
I
I
I
,/
/
/
/
/
/
/
/ /
/ /
/
15% - 20%
/
/
/
/ /
/ /
/
//
/
/
/
/
~ Jo
Proposed
Well
10%
SITE PLAN
-- SCALE 1" = 50'
I Jo
-- ~2,000 Gallon Recirculating
'~ _ Septic Tank
Four Bedroom / ~ Upflow Filter
Home /, ~
_ ~ Sample Basin
Absorption Bed
SYSTEM PLAN
NO SCALE
LOT 1, BLOCK 2, PROSPECT HEIGHTS
SUBDIVISION, NO. 4
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four Bedroom Home
Perc. Rate: 7 MinJInch
Application Rate: 4 GPD/SF
Shallow Bed System
2,000 Gallon Recirculating
Septic Tank with Upflow Filter
4 Bedrooms X 150 GPD = 600 Gallons Per Day
600 GPD/4.0 GPD/SF /15 LF Width -- 10 LF Total Length of Bed
Therefore: Construct a Shallow Bed System 15' Wide X 20' Long.
Distribution Piping to be Placed at Ground Surface. Mound Over Bed To
Provide 3' of Cover or Provide 2" of Direct Bury Insulation and 2' of
Cover. Replace Organic Material with Lake Otis Sand (Specification
Attached).
atural Backf
/ ~ 2" HI Direct Bury Insulation
Remove Existing Organic Material
Replace With Lake Otis Sand
(See Attached Specification)
1 ' Drainfield
Rock
.5'
2.5' 5' 5' 2.5'
NOTE:
SHALLOW BED SECTION
(NO SCALE)
Grade Area to Drain Away.
Maintain 4' Separation From Bedrock.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
f .. oo'.?:~ ,
PERFORMED FOR, Pamela Dahl DATE PERFOR~M~~
LEGAL DESCRIPTION: Lot 1, Block 2 r Pros- Township, Range, Sectiom '-, - -
1
2
3,
4-
5-
6
7
8
9,
10-
1I
pect Heights, No. 4' SLOPE
I3
14
15
16-
17-
18-
19-
20
COMMENTS
WAS GROUND WATER
SITE PLAN
ENCOUNTERED?
,.'E,. A','W.A','
DEPTH?
~ None
$'. ,.lo .~o
9:/I
PERCOLATION RATE 7
T~ST RUN BETWEEN
Test Cavity Presoaked Prior to Test.
(minutes/~ncl3} PERC HOLE DIAMETER
FT AND /'~ Fi'
· ' '""'--~'~"'"'~ THAT/?HI$~'EST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ', ~/f'S'-/~ ~
72-008 {Rev. 4/851
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH '& HUMAN SERVICES
825 'L" S~ee~ Anchorage, AJaska 99502~650
SOILS LOG -- PERCOLATION TEST
Pamela Dahl
LEGAl. DESCRI~IO~: Lot 1 r Block 2 r Pros- Townshil~, Range. Section:
pect Heights, No. 4' SLO,E
2
6,
7-
,,,J,,,o
8
9
10 WAS GROUND WATER
11-
I2-
13-
14-
16
17-
18-
. 2O
COMMENTS F]ateri ~ 1
ENCOUNTERED? No
E
IF YE~. AT WHAT ~
DEPTH? p.
None ~.. 8/5/qR
Gro~ Ne~
Time Time
'
Similar to Testhole No.
PERCOLATION RATE tminute~,ncn; pER¢ HOLE DIAMETER
TEb'T RUN BE'~VEEN FT AND FT
1
:ERFORMED SY. , ! ~~:~~HAT TH/S ~ WA~. P~RFORMED iN
CCORDANCE WITH ALL STATS AND MI2NICJPAL GUIDELINES IN EFFECT ON THIS DAT[ DATE: . ~/~/¢~
72~08 {Rev. 4/85)
Mu~cJpality of Anchorage
DEPARTMENT OF HEALTH '& HUMAN SERVICES
825 'L' stree~ Anchorage. AJaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:.., Pamela Dahl
LEGAL DESCRIFTION:,.Lot 1 r Block 2t
~ect Heights, No. 4
2
3
4,
$-
6
7
8
9-
10
12
15
16
19
20
COMMENTS
OATE PERFOF
Pros- Township, Range, Sectiorc
WAS GROUND WATE~
ENCOUNTERED? , NO
IF Y;~. AT WHAT
DEPTH?
None
Sl~ P~AN
· , {minute~.mcll) PERC HOL~ DIAMETER ,, ~ ~
TEST RUN BETWEEN., J PT AND ~ FT
Test Cavity Presoaked Prior to Test.
ACCORDANCE %%1TH ALL STATE AND MUNICIPAL GUIDEL NE$ IN EFFECT ON THiS DATF-- OAT;' '-- ~)/~/¢~ ~
72~08 (Rev. 4/S5)
0
RECIRCULATING LiFT
STATION SEPTIC TANK
WITH TRICKLING FI~.TER
& UPFLOW FILTEil
iNCflOr, iGE TiN[ i WELOHG, NC,
0
,<
~AN K
HEAD
MANHOLE
7"¢ HUB
HOLE IN
BAFFLE
W/6"¢
TANK
15
30" 80
MANHOLE
HEAD
~NG L~FT
STATION SEPTIC T.~NK
wrr. TRICKLING FILTER
RECIRCULATING LIFT
STATION SEPTIC TANK
WITH TRICKLING FILTER