HomeMy WebLinkAboutASPEN HIGHLANDS #3 BLK 3 LT 12Aspen
Highlands #3
Block 3
Lot 12
#017-013-74
Municipality of Anchorage
Community Development Department Page 1 of 3
On-Site Water & Wastewater Program
4700 Elmore St. - P.O. Box 196650 Anchorage, AK 99519-6650 • http:11www.muni.org/onsite a (907)343-7904
ORI-SITE WASTEWATER iNSPECTION REPORT
Permit Number: OSP121026 PID Number. 017-013-74 ❑ New ®Upgrade
Nome: DOUG MUTTER ABSORPTION FIELD.
Address: D Deep Trench D Shallow Trench IR Bed D Mound
7621 UPPER DEARMOUN RD *ANCH., AK 99516 E3 Other.
Phone: No. of Bedrooms: Soil Rating: Total Depth from original grade:
(907) 440-2082 4 3 .o GPD/Sq- Ft. *0.63 FL
LEGAL ®ESCPJPTION Depth to pipe Invert from orlginal grade: Grovel depth beneath pipe:
6" 0.22 t. 0.5 Fl.
Subdivision: Block: Let: Fill added above original grade: Gravel length:
ASPEN HIGHLANDS #3 3 12 SEE DWG. F. 40 Ft.
Township: — Range: — Section: _ Growl width: Beds Number of lutes Diolance betwaen fines
ap�p� �+�pp®�/+ 20 Ft. 4 5 Ft.
SEPARATION DISTANCES P�1 CES Total absarptlon Oreo: Number of tranches: DILL between lrenchex
To
Septic Absorption Lift Holding ublic/Private — —
From Tank Field Station Tank Sower Lines X00 sa- Ft. Ft
Well 100'+ 100'+ 100'+ — 25'+ TANK D Septic ®S.T.E.P. OHoldin ❑Other '
Manufacturer: Capacity.
Surface Water 100'+ 100'+ 100'+ — GREER 1500 GaL
Material: Number of compartments:
Lot Line 5'+ **5' 5'+ — N/A
STEEL 2
Foundation 5'+ 10'+ 5'+ — LIFT STATION
Curtain Drain Manufacturer: Capacity.
NONE KNOWN
GREER/QUANICS 1500 cal.
OLD TANK WAS DECOMMISSIONED PER UPC. pomp o" level at: Pump air level at: rh water alarm at:
Remarks: TIMER TIMER 46"
THIS IS A QUANICS AEROCELL SYSTEM. Pump Make & Model: Electrical Inspections perfarmed by.
"ORIGINAL GRADE WHEN SYSTEM WAS ORIGINALLY INSTALLED, P—SE-41T MOA
PIPE MATERIAL 5e,
** ct�iairi, � �
UNDER FILL/SYSTEM SOIL COVER. WAIVER GRANTED P Tank to
House to tan drainfield SCH 40
Installer Drainfield PVC.3034 CO/MT PVC 3034
REEKS EXCAVATING
Inspector GEG, Ltd. BENCHMARK (Assumed elevation)
100.00 Ff.
Inspection Location and Description:
Dates: 1st 3/22/12 2nd 3/22/12
3rd 3/23/12 4th 3/23/12 BOTTOM OF TRIM SW CORNER OF HOUSE.
ENGUYEER•S e
Community Development Department Approval
�4
Conditional approval: Date: p�,`P:• '-�-�
e r A�Go ess,=•..�
CE-79 qj
Approved: Date: pG` rofesSjor1aa
4400 o
Co h V 2.(S i a V) -�rb rn 0, CA T M —4-o o. /QAT 3( L�-r'ln i C S
SoS4em o ooI vved 7/.31/_J�-qP7 — -PdA,",,,
GARNESS ENGINEERING GROUP, Ltd AC ell'
_.� - ENGINEERING, SALES, CONSULTING-„ •-«�-- .,_ _ Alaska Aathorize¢iDealer
June 30, 2020
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Rd. P.O. Box 196650
Anchorage, AK 99519-6650
(907) 343-7904
Ref: Aspen Highlands SID #3; Block 3, Lot 12 (7621 Upper Dearmoun Rd., Anchorage, AK)
Memo concerning converting CAT III AWWTS to CAT 11 AWWTS septic system
To whom it may concern:
The permitted septic system was installed on the referenced property on 3/22-23/2012 and
started up shortly after the installation. ARM Septic Services, LLC has recently checked the
monitoring tubes in the drainfield and found them to be dry. In order to simplify the operation
and maintenance of the system, we are proposing that this unit be permanently configured
as a CAT 11 system. Our justifications are as follows:
According to Leroy Reid, P.E.'s 1982 soil log, the receiving soil has a percolation rate of 10
minutes per inch. Given this percolation rate, a 3.0 gpd/sq.ft. application rate is required for a
Cat 11 system.
The home has 4 bedrooms, so 200 sq./ft. of absorption area is required for a CAT If effluent
(600 gpd 13.0). The existing 2012 drainfield has 800 sq./ft of absorption area. We would also
like to note that there is 1 foot of MOA filter sand below the drainrock.
The approved On-site Wastewater Inspection Report stamped and signed on 9/9/2009 shows
the soil rating to be 6.0 gpd/sq.ft. We request the Inspection Report be amended to show a 3.0
gpd/sq.ft. application rate.
At this time, we request that your department approve a CAT 11 configuration to be used at
the referenced property. Upon your concurrence, we will have ARM Septic Service, LLC., go
to the property remove the actuator from the ball valve or leave the valve in the open position,
and have them dace a CAT 11 sticker on the control panel.
M.S.
Press el�e
3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineedng.com
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSP121026
01701374000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 995'19-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: March 15, 2012 to March 15, 2013
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: ASPEN HIGHLANDS #3
Site Legal Address: ASPEN HIGHLANDS #3 BLK 3 LT 12 G:2840
Owner/Address: MUTTER DOUGLAS L & CAROL SUE
7621 UPPER DEARMOUN ROAD ANCHORAGE AK 995163804
Site Mailing Address: 7621 UPPER DE ARMOUN RD, Anchorage
Lot Size in Sq Ft: 25274
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours pdor to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
.A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Previsions: 1. Construction equipment is prohibited from being on the bottom of the bed to
ensure that the native soils will not be compromised.
Special Provisions: 2. During construction, the elevation of the native organic layer must be verified
to ensure that the required separation to groundwater is met.
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww, muni,or,qlOnsite
Development Services Division
On-Site Water and Wastewater Prooram
**** VARIANCE/WAIVER REVIEW ****
WaiverS: OSP12t027 COSA#: Permit:
PID~: 017-013-74
Legal Description: Aspen Hiphlands #3 Block 3 Lot 12
Engineer: Garness En.clineerina Grou[~
OSPt2'1026
Applicant: Douo and Carol Mutter
Your request for a waiver of the required 10 feet horizontal separation fi.om the absorption field
to the property line has been approved. The approved separation distance is 5.0 feet.
This waiver approval applies to the proposed absorption field only..Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
appro-~al fi.om this department.
[] The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
[] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
[] Adjacent properties are not affected by this waiver.
Waiver is Granted: X Waiver is not Granted:
...... ~..q...~.. ............ ..... .......... .......~.~.m:. o.?.?.~t~.~..,.,,,, ..........
Recf~: 00537G Amount: $200.00 Date Paid: 3/6/12
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & Wastewater Program
Phone:907-343-7904
Fax: 907-343-7997
Mayor Dan Sullivan
On-Site Sewer/VVell Permit Application
For A Single Family Dwelling
Parcel I.D. 017-015-74-
Property owner(s) DOUG & CAROL MUTTER Day phone 44-0-2082
Mailing address 7621 UPPER BEARMOUN ROAD *ANCHORAGE, AK 99516
Site address 7621 UPPER DEARMOUN ROAD *ANCHORAGE, AK 99516
Legal description (Sub'd, Block & Lot ) ASPEN HIGHLANDS #5; BLOCK 5, LOT 12
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms 4-
THIS APPLICATION IS FOR:
( [] all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
PROPOSED DRAINFIELD TO WEST LOT LINE.
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of properly owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit NO. Osp
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No. OS
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
March 2, 2012
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Septic Upgrade for Aspen Highlands #3; Block 3, Lot 12
To whom it may concern:
The existing 4 bedroom house is served by a private well and septic system. The septic system is
in a state of failure and needs to be upgraded. We are proposing to rebuild the existing
(undersized) drainfield and install a new 1500 gallon S.T.E.P. tank with Qum~ics controls/floats,
and install a 650 Aerocell trickling filter. The proposed re-built bed will be 20 feet in width
rather than the 15 foot max stated in code. The additional 5 feet in width will not compromise the
longevity of the re-built bed due to the incorporation of a CAT III nitrogen removal systean.
Also, during construction the contractor will be prohibited from walking equipment on the
bottom of the bed to ensure that the native soils will not be compromised (Please state as
provision on permit). The Quanics product may be switched out with the Orenco Advantex
treatment system if the home owner chooses to do so. GEG discussed the option of digging
additional testholes with the homeowner to see if it would be possible to install a conventional
septic system and they opted not to pursue this choice.
1. SOILS: See the 1982 Leroy Reid, P.E. soil log (attached) which shows the soil
classifications, groundwater monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There is a road ditch to the south of the property which runs along
Upper DeArmoun Road and is filled with bone rock. There are no surface waters within 100 feet
of the proposed septic system.
4. TOPOGRAPHY: As can be seen on the attached design drawing the topography around the
drainfield is relatively flat. In short, there are no slope concerns.
5. LOT LINE WAIVER REQUEST: We are requesting a 5 foot lot line from the proposed
drainfleld to the west lot line. There is no concern of separation distances from the proposed
drainfield to either the well, house, or septic system located on Aspen Highlands #3: Block 3,
Lot 11 (property to the west). The elevation of final grades for the proposed bed will either be at
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. garnessengineering.com
grade or worst case scenario 1 foot above final grade. In short, there should be no conflict with
3:1 slopes encroaching onto the neighboring lot.
During construction, the elevation of the native organic layer (if it exists) will be verified next to
the bed. Ground water monitoring (G.W.M.) fzom 1981 was at 6 feet below grade. The new top
of sand elevation will be at 1 foot below the native organic layer or higher. In short the 5 foot
separation requirement to GW will be met. (Please state this as a provision on penni0.
We are unaware of any adverse impacts this installation and granting of the waiver request
would have on adjacent wells or septic systems. If you have any questions, please contact us at
337-6179· Thank you for your assistance.
NOTE: Attached is a site plan drawing, a design drawing, which are all part of the design
package for this septic system. (Contact G.E.G. Ltd. for 7page construction specification letter·)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. gamessengineering.¢om
r
.... _~ ..... I--~_~ ........ ~___~
KIMBERLY ~ / / / I
MANOR; ~ / / I N 100' WELL I
BLOCK 1, ~ ~ / 1Jo0' WELL J RADIUS
LOT 13 ~ ~ / ~DiUS I J
MANoR;KIMBERLY ~ MANoR;KIMBERLY ~ ~ ~ > KI M B E~ L~ KIMBERLY
BLOCK 1. ~ BLOCK 1, M~; MANOR;
I
GARN:ESS ENGINEERING GROUP, Ltd ~'"
DOUG A CAROL MUTTER 440-2082 J 1 OF ~
ASPEN HIGHLANDS ~3; BLOCK 3, LOT 12 PNB
~PE OF WORK: DATE:
SITE PLAN 3/2/12
(Rev. 01/05)
DESIGN CRITERIA:
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPO): 600
PERCOLATION RATE/S: *,3.55
PROPOSED APPLICATION RATE: **6
MINIMUM DRAINFIELD SQ.FT.:
*PER PREVIOUS DESIGN AND INSTALL
**ADVANCED TREATMENT
DRAINFIELD DESIGN:
MAXIMUM DEPTH: REMOVE ALL CONTAMINATED MATERlt
WIDTH: 20 FEET
LENGTH: 40 FEET
M.O.A. APPROVED SAND FILTER: SEE NOTE
EFFECTIVE: 0.5 FEET
REDUCTION FACTOR: N/A
ACTUAL SQ.FT.: BO0
GLO, Ltd. HAS A 7 PAGE SPECIFICATION
LETTER THAT PERTAINS TO THIS DESIGN.
TO OBTAIN A COPY OF THE LETTER
CONTACT GEO. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
CONDITIONS OUTLINED.
NOTE: THE CONTRACTOR
SHALL HAVE THE WEST LOT
LINE AND ALL WELL RADII
FLAGGED BY A REGISTERED
LAND SURVEYOR PRIOR TO
CONSTRUCTION.
ASPEN HIGHLANDS
BLOCK 3, LOT 11
100' WELL RADIUS
I
/
/
/
HOMEOWNER MAY SUBSTITUE THE QUANICS
TREATMENT SYSTEM FOR A LIKE PRODUCT SUCH
AS THE ORENCO ABVANTEX TREATMENT SYSTEM.
/ /
/ /
/ /
EXISTING SEPTIC TANK TO BE
-"DECOMMISSIONED" PER UPC.
,
EXISTING 4 BEDROOM
HOUSE
1500 GALLON
W/ QUANIBS
30NTROLS.
TN#l
*
NOTE f~l: 18' x 38' EXISTING DRAINFIELO~-
PROPOSED TO BE RE-BUILT AT 20' X 40'. '~'
REMOVE ALL CONTAMINATED MATERIAL AND IMPORT
MOA APPROVED SAND. REBUILO SAND ELEVATION
TO BE EQUAL TO OR HIGHER THAN THE
ELEVATION OF' THE EXISTING BED BOTTOM.
/
/
/ \
\
\
UPPER DEARMOUN ROAD \
ASPEN HIGHLANDS #3; BLOCK 3, LOT 12
~00' WELL RADIUS
SCALE:
1" = 40'
GARNESS ENGINEERING GROUP, Ltd.
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
DOUG & CAROL MUTTER 440-2082 2 OF .3
LEGAL DESCRIPTION: DRAWN BY:
ASPEN HIGHLANDS #3; BLOCK $, LOT 12 PNB
TYPE OF WORK: DATE:/3
SEPTIC DESIGN UPGRADE 2/'12
(Rev. 01105)
SHELL ' ~2 ~
~IGH WATER ~M
JANDY VALVE ~OAT 27"
/'650 TR~TMENT UNIT
/w~
/ / =." c~.o~=
/ /
24" INSULTED LID~ 4" BY 4' WIDE RIGID
/ UL LISTED SPLICE BOX /
UR~HANE WITH TOPCOAT~
.vc co. u,,
2" TO 4" OF INSU~TION
OVER TAN K.~ - II
............... ~ I~TIMER OVERRIDE FLOAT
~ 1500 GALLON S.T.E.P.
TANK SUPPLIED BY GREER TANK
AROUND ENTIRE PERIM~ER~ ~ ~P-SE-41T EFFLUENT PUMP
"RGH WATER ALARM 34 6")
3VERR,DE FLOAT 32"(44")
JANDY VALVE FLOAT 27" 39"( ~
ON/OFF FLOAT 15"(27')
(Rev. 01/05)
~ CONSULTANTS & GE~-4ERAL OONTFL~CTOR$
S01L LOG - PERCOLATION~
LEGAL DESCRIPTION: ASPEN .IGH~NDS
PERFORMED FO*' DOUg & CAROL MUTER DATE.~12
DEPTH ~
(feet)
' FILL/ORGANICS TEST HOLE
SOIL C~SSIFICATIONS
OM CL
GC OL
~ SP CH
SM OH
SEE ATTACHED SiTE PLAN
SC
DEPTH TO
GROUNDWATER DATE
~L DRY 2/21/12
~/28/12
SCALE:
10
11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (~NCHES)
i 2 2/21/12 1 2:~6 - 8.00,, -
2 3:13 50 5-12/16" 4/16"
13 3 3:13 - 6.00" -
4 3:43 30
1 ~ 5 3:43 6.00" -
6 4:13 30 5-12/16" 4/16"
16 PERK AT DEPTH OF 6 FEET INDICATES
~ IMPERMEABLE SOILS.
18
19 PERCOLATION RATE 120 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 2.5 FT. AN~ 3.5 FT.
20 A FOUR HOUR P~ESOAK WAS PERFORHED: ~ YES ~ NO
SOILS LOSGED BY: ROB CAMPBELL PERCOLATION TEST PERFO~HED BY: ROB CAMPBELL
COHHENTS:
PERFORMED BY GEG, Ltd. I, JEFFR~ A, GARNESS, CERTI~ THAT THIS WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
DEPTH TO
GROUNDWATER DATE
DRY 2/21/12
2/28/12
(907) 243-2282
KEN JOHNSON
KEN'S COMPANY
WATER WELL DRILLING
PUMP SALES & SERVICE
30 YEARS ALASKA DRILLING
3163 LINDEN DRIVE
ANCHORAGE, ALASKA 99502
AUGUST 26, 1983
TON GORE
600 Wo 45th # 6
Anchorage, Alaska 99503
( Wk. 266-3716
Hm. 561-8570 )
RE; Lot 12 Blk. 3 Aspen Highland Sub°
WATER WELL LOG
0 ft to 2 ft
2 ft to 17 ft
17 ft to 29 ft
29 ft to 35 ft
35 ft to 42 ft
42 ft ~ 49 ft
49 ft ~ 55 ft
55 ft to 57 ft
57 ft to 70 ft
70 ft to 77 ft
77 ft to 87 ft
87 ft to 102 ft
102 ft to104 ft
104 ft to 115 ft
115 ft to 120 ft
120 ft to 125 ft
125 ft to 127 ft
127 ft to 128 ft
128 ft to 138 ft
138 ft to 141 ft
141 ft ~ 149 ft
149 ft to 155 ft
155 ft to 161 ft
161 ft to175 ft
175 ft to 182 ft
182 ft to 189 ft
189 ft to 191 ft
191 ft to197 ft
197 ft to 200 ft
Brown silt & organics
Light brn silt & med. grav.
Water bearing sand ( seepage )
Lt brn silt and medo gray.
Course gravel and gray silt
Ned. gray & gray silt
Course grav& gray silt
Tight formation
Ned. gray & gray slt.
Course grav& gray silt
Light brn silt ( clay texture ) Some fine gravo
Same with small ~2o seams..½ Gpm..
Boulders ( rotate casing 180 degrees )
Course gray & it brn silt
Ned. grav& lto brn silt
Same but weeps H2o
Same but dry
Weeps .. 20 ft. head bails dry poor ~ecover~y.
Course gray & it brn silt dry..
Weep in 30 ft. bail dry poor recovery
Lt brn silt & med. grav . dry ..
Course grav ~and gray sil
Noulders..
Ned° gray & It brn silt
Clean Wate~-bearing Sand and gray I 1/2 Gpm
40 fto overnight static head
Course grav& brn silt dr~
Ned sand &grav. H20 I 1/2 GPM 35 ft head°
Course grav. and brn silt ..dry..
Clean med gravel and sand ,Water bearing
Three GPM
6!0 ft Head
Perforated casing at 175 ft to182 ft and 187 ft
to 191 ft with Star perforator.
Surged and bailed
Test bailed well 2 hours at 6 GPN
Static 140 ft ( 60 ft head )
Drawdown to 180 ft ( 40 ft. ) at 6 GPM
Bottom stable
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DATE PERFORMED: '~- ~"7" ~'~"''
SITE PLAN
WAS GROUND WATER S
ENCOUNTERED? L
O
P
E
IF YES, AT WHAT
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
·
/
PERCOLATION RATE ("r~i,m,tte~j nc h )
TEST RUN BETWEEN ~ p' 1~Tr.~ll~l!~ ~ .FT,,.~
~'/~ ~ 9~/, ~':~"~' ....'"'~'
72-008 (6/79) .... ' ~ .....
Test Hole ~12A-3
Lot 12, Block 3
TABLE A
W.O. ~A19800
Date: 5/27/81
Logged by: OMH
Depth in Feet
From To
0.0 1.0
1.0 6.0
6.0 8.0
8.0 10.0
Soil Description
Brown Peat, (Pt), moist, soft
F-2/F-3, brown Silty Gravelly Sand, (SM),
moist, med dense, poorly graded~ 3".+
F-4, brown Gravelly Sand~/ Silt, (ML), moist,
stiff, N.P.
F-l, brown Silty Sandy Gravel, (GM), saturated,
medium dense, poorly graded, 3"+
Sot 3/4" perforated PVC pipe to monitor water table
elevations,
Bottom of Test Hole:
Frost Line:
Free Water Level:
10.0 Feet
None observed
8.0 Feet
5/28/81 7.5 Feet
6/8/8'1 6.0 Feet
Sa.
No. Depthm
I 5'
2 10~
Type of Dry
Blows/6" M__~ Sample Strength GrouE)'
V SM
V GM
Temp.
Unified °F
Remarks:
1. Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
2. Dry Strength, N=None, L=Low, M=Medium, H=High.
3. Group refers to similar material, this study only.
4. General information, see Sheet 1.
5. Frost and Textural Classification, see Sheet 2.
6. Unified Classification, see Sheet 3.
2X - 2 -
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information Applicati6n Date 11-78-84
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot.12. Block 2. As~en Highland Subdivision
Location (address or directions)
7621 DeArmoun Rd.
(b) Applicants Name Tom Gore Telephone - Home 345-~7~siness
Applicants Address 7621 DeArmoun Rd.
(c) Applicant is (check one) Lending Institution ~--~ ; Owner/butlder~ ;
Buyer ; 0ther --U (explain);
(d) Lending Institution Alaska State Bank Telephone 265-2257
Address 310 E. Northern Lights Blvd.
(e) Real Estate Co. & Agen~
(f)
Heritage Homes
Address 207 E. Northern Lights Blvd.
Telephone 276-1333
Mail the HAA to the following address:
Will pickup
Ken Meckaen -- ~ ~-'~ ~ t L5 1515
2. ~ype of Residence
Single-Family~
Number of Bedrooms
3. Water Supply
Individual Well~
Multi-Family,~-~.
4
Other (describe)
Community
Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal,.
Onsite ~ Public ~-~ Community ~, Holding Tank ~
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
5. En$ineerin$ Firm Providin~ Inspections~ Tests, File Search~ Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
Name of Firm Arctic Engineers, Inc.
Address 1506 West 36th Ave., Ste. 201 Anchorage, AK 99503
(ENGINEER SEAL)
Date 11-28-84
DHEP Approval
Approved for
Approved~__
bedrooms
Disapproved __ Conditional
Terms of Conditional Approval
Telephone 561-%345
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS- AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DHEP SEAL)
RR4/eJ/D18
[Page 2 of 2]
7-19-84
ae
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (BAA)
CHECKLIST - FEBRUARY 1984
LEGAL:
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION~
NOV 1ga'-',.
RECEIVED
Lot 12, Blk 2, Aspen Highlands Subd.
Well Classification Individual
Well Log P~esent (Y/N) Y
Total Depth 200' Cased to
Static Water Level 140'
Casing HeightAbove Ground 12"+
Electrical Wiring in Conduit (Y/N)
Separation Distances frcm Well:
To Septic/HoldingTank on Lot
Date Campleted
191' (perf.)
If A, B, c~ C, D.E.C. App~oved(~/N) __
8-26-83 Yield..6 gPm ....
Depth of Grouting unknown
Pump Set At unknown
Sanitary Seal on Casing (Y/N)y
Y Dep~essionA~oundWellhead (Y/N)N
100' +
; On Adjoining Lots.~ !00'+
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line N/A ... To Nearest Public Sewer
Cleanout/Manhole N/A TO Nearest Sewer Service Line on LOt
Water Sample Collected By Duane Maney ; Date 11-27-84
Water Sample Test Results Satisfactory for Total Coliform
ComTents
100' + ; On Adjoining Lots 100' +
B. SEPTIC/HOLDING TANK DATA
Date Installed August 1983 Size 1250 No. of Compartments 2
Standpipes (Y/N.) Y ....... Air-tiGht Caps (Y/N). Y.. Foundation Cleanout (Y/N) Y
Depression over Tank .(Y/N) N Date Last Pumped installed in Aug. 1983 '
PumpinG/Maintenance Contract on File (Y/N) N ; fo~ ....
Holding Tank High-Water Alanm (y/N) .N Temporary Holding Tank Permit !..Y/N.) N .
Separation Distances f~cm Septic/Holding Tank:
To Water-Supply Well
To PFope~ty Line 5' +
To Water Main/Service Line
Course None Noted
100' ~
, N/A
TO Building Foundation. .5' +
To Disposal Field .... 5' +
To Stream, Pond, Lake, c~ Major D~ainage
Ccm~rents
Septic tank installed in August 1983.
[Page 1 of 2]
2-15-84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Stzata
Date I~stalled August 1983
Width of Field 18'
Square Feet of Absorption A~ea
Depression ove~ Field !,,Y/N)
Results of Last Adequacy Test
165 Type of System Design ~,Drainfie,l,d, ,
Length of Field 36'
Depth of Field 1.75 '. (a~p~ox.),
Gravel Bed Thickness 2.5" (approx.)
648 Standpipes P~esent (Y/N) Y
N Date of Last Adequacy Test installed in 8/83
installed in 8/83
Separation Distance f~cm Absorption Field:
To Water-Supply Well 100' +
To Building Foundation
Lot None
TO Wate~ Main/Service Line
18'
To P~operty Line 10' +
To Existing or Abandoned System cn
; On Adjoining Lots $0' + 4,,,
N/A, TO Cutbank(if present)
To Stream/Pond/Lake/or Majo~ D~ainage Course None Noted
TO D~iveway, Pa~king Area, or Vehicle Storage A~ea 10' +
Co~-~nts Absorption field installed in August 1983.
None
D. LIFT STATION N/A
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested fo~
E le ct~ i cal Code s (Y/N)
Ccm~ents
Dimensions
Manhole/access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles du~ing Adequacy Test.
M~ets MOA
** Check Permitted Bedroom Rating A~airk~t HAA Request
I certify that I have checked, verified, o~ confc~med to all MOA HAA Guidelines in effect
on the date of this inspection.
Signed Date
C~anyArctic Engineers, Inc. MOA No.
KB1/d5/s
[Page 2 of 2]
ST 84-001
Sheet
WATERWELL - TEST PUMP REPORT
Conducted by .t~_~.,4-)' ~ ~('~,~,,~.,,t.~,~. _.~,/4' ,.~,'~/_~',_;~" ~/~~~
Owner ~ ~ ~yZ-~.~ Address
Well Information: Ttl. Depth ~Depth of Casin~Screen From
Casing Size ~~reen Diam ~ Screen Slot
Pump Information: Intake Depth/~ P~mp ~e- -~ ~ /~ ~ ~,
Static Water Level /~ . Ay. Discharge ~ ~ GPM, Max. Drawdown
Pump On: Time /. ~ -Da~e/~~ Pump Off: - .Time
- / /- -
WATER PIEZO- FLOW REMARKS REMARKS
TIME LEVEL TUBE GPM
I~O / ~0 ~, ~ ~ ~