MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241072
Work Type: SepticTank Upgrade
Tax Code Number: 01827160000
Site Legal Address: TIMBERLUX #3 BLK G LT 6 G:3136
Site Mailing Address: 4645 MANYTELL AVE, Anchorage
Owner: CUSHMAN CHARLES R & KAREN L
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
�1»ant
f+
De partIII ell t
5/13/2024
5/13/2025
56400
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: I S .S—P C'7 C, Date:
Issued By: �/� Date: j Z
5
Development Services Department P P `� �� Phone: 907-343-7904
On -Site Water & Wastewater Section �=-' Fax: 907-343-7997
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 018-271-60
Property owner(s) KAREN CUSHMAN
Mailing address 4645 MAYTELL AVENUE *ANCHORAGE, AK
Site address 4645 MANYTELL AVENUE *ANCHORAGE, AK
Day phone 907-345-4571
Legal description (Sub'd., Block & Lot) TIMBERLUX #3; BLOCK G, LOT 6
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 4(5BEDSEPTIC)
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑ Initial
Single Family (SF) 0
Septic Tank
_'
0 Upgrade ®
(w/wo ADU)
Holding Tank
ElRenewal ❑
Duplex (D) El
Privy
❑
Multiple Dwellings ❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:ZZ C,
Date of Payment: y �30�2 y
Receipt Number: O CI V S 6 6
Permit No. 2 `{ j 07Z
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and WastewaterTormslClient Forms\Permit Application.doc
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241072, Curtis Townsend, 05/13/24
ARM Septic Services, LLC
4/12/24
Karen and Charles Cushman
4645 Manytell Avenue
Anchorage, AK
Subject: Reactex septic system site visit summary
To whom it may concern:
ARM Services was onsite in January (as well as a follow up visit in April) responding to the subject
property due to an alarm condition observed at the control panel. Upon arrival, the system control
panel was found to be in Auto, and the alarm tight on. The audible alarm appeared to have been
previously disconnected and did not appear to be making sound. Please see the below findings and
recommendations for repair. An April update can be found at the end of the report.
OBSERVATIONS:
Septic Tank:
-Upon arrival, the septic tank appeared to be operating about 3ft surcharged (overfull), and the two
pumps were not activating properly. Both of the pumps in the 2nd compartment/lift station were
tested, and initially did not appear to be responding to testing. The discharge pump was pulled and
intake screen checked; this was found to be fairly clogged with hair and biomat. ARM cleared the pump
intake fitter and tested again. Once the discharge pump was placed into hand, effluent was observed
properly leaving the lift station towards the upflow fitter. The liquid level appeared to be dropping in
the lift station during manual pumping of the discharge pump. The intake filter was cleaned on the
recirculation pump as well, and this pump property responded to testing as well. However, once the
liquid level was dropped in the lift station (by pumping out through the up -flow filter), it was observed
that there was a large steady stream of effluent returning to the tank during recirculation pump
testing. Further investigation revealed that this was likely due to a hole that was observed around the
pressurized line leading from the recirculation pump to the trickling filter. It is reasonable to believe
that the pressurized line is fractured or broken out side of the tank, as no iqui was o served reaching
the tric ing fitter see a ow . i e ARM was not a e to visually inspect the possible hole in the
sidewall of the riser, given the age of the tank (26+ years) it is likely that the original hole for the
pressurized line has rusted out and is not properly seated.
-The "discharge timer on" float did not appear to be contacting the panel properly during testing.
Despite the liquid level being high enough to activate the timers, the Discharge pump timer in the
control panel did not appear to be activated. During testing, it was intermittently observed activating
the timer, but not reliably.
-All of the components of the lift station were observed to be heavily biomatted during the site visit.
Annual maintenance helps to keep the components clean and operating property.
Summary: The system did not appear to be operating as it was designed due to a likely broken pipe
underground, and was pumping untreated effluent up to the drainfield. Given the age of the tank, it
may be worth replacing the tank vs. repairing these deficiencies
Trickling Filter:
-There was no observed flow through the spray nozzle during ARM's site visit. This can likely be
attributed to the previously mentioned broken pressurized line, as the pressurized line services this
fitter. The spray nozzle appeared to be clear, based upon a visual inspection.
-The treatment media was observed to be fairtv heavily biomatted and brid�in�, and did not appear to
have been in use for some time (likely due to the above broken pipe). It was also observed that the
vertical separator for the media sheets had fallen down and was no longer spacing the sheets out
properly.
Upflow filter:
-The drainfietd was observed to be dry when ARM arrived onsite, and maintained as such throughout
the site visit.
-The upflow filter appeared to be allowing liquid to pass through it property, and was observed
transferring liquid to the drainfietd.
17933 Old Glenn Highway *Chugiak, AK 99567
office: (907) 688-9433 Email: ARMServicesAK@outlook.com
_n v
ARM Septic Services, LLC
RECOMMENDATIONS:
-A proper maintenance and cleaning should be completed on all of the components of the lift station to
ensure proper treatment and operation.
-The Discharge pump timer on float should be replaced. (Due to the age of the system, it is possible
that other electrical deficiencies may be present and uncovered during float replacement.)
-The alarm should be reconnected to provide the code required outdoor alarm.
-The pressurized tine should be dug up and repaired, and hole in the sidewall of the tank seated to
prevent unwanted groundwater and surface water from entering the tank.
-Given the age of the tank and conditions found while onsite, it may be prudent to replace the
septic tank instead of completing repairs. Due to the tanks age, the sidewall of the tank may
not be able to be seated during the repair. Coupled with the conditions of the other components
in the system, the best use of funds may,he to upgrade the system to an Wgraded septic
system. Septic tanks have a lifespan of 20-30 years, and given an install ate of 1998, it is likely
that the tank has other holes. The system is quickly approaching the 30 year mark, at which the
point the tank would have to be replaced when the house is sold. Tank/system replacement
would supersede all other recommendations.
-The treatment media should be cleaned and treated to clear the biomat and bring the system back up
to health.
-The treatment pod's vertical separator should be installed correctly to maintain spacing between
sheets.
-To protect the drainfietd, it is recommended that proper maintenance, repairs, or replacements are
completed on the other components to prevent damage. It is reasonable to believe that the system
may continue operate for a short time in its current configuration, but if left long term the drainfield
may show signs of failure and require attention. Due to the probable broken pressurized line, there is
no secondary treatment happening to the effluent, and the system is pumping poorly treated effluent
to the drainfield. Poorly treated effluent can drastically shorten the lifespan of a drainfield.
APRIL UPDATE:
-ARM responded to a backup of the system, the cause of which was likely due to a tripped breaker. The
system was pumped down via pump truck to provide relief and the ability to inspect the system. During
the inspection, it was revealed that the recirculation pump was no longer properly responding to
testing, and appeared to be in need of replacement. Additionally, the foundation cleanout was
observed to be holding some liquid, so ARM snaked the line but did not find any obstructions. Further
investigation into the septic as built showed that the other cleanout next to the house was a part of a
venting system for the treatment pod, and not a part of the sewer line as thought while onsite. Other
site conditions were found to be as observed during the January site visit. Budgetary repair/
replacement costs include replacement of the sewer line from the house.
For a rough budgetary estimate, it is likely that all of the aforementioned repairs could cost $12 000-
18,000 (budgetary, subtract $3,500 if sewer tine from house is no rep ace wit repairs). Th_ !s option
wou still leave a 26+ year old tank serving the system, possibly leaking
and causing diminished
treatment. I spoke with JeffGarness over at Garness Engineering, and it is is opinion that a tank
upgrade wilt also require a treatment pod upgrade as welt, as the MOA will not approve continued use
of the existing treatment pod with a new tank install. Approximate cost for upgraded treatment system
and tank would run $45,000-$55,000 (price is depending on components required for the property, does
not include engineering or landscaping costs. These can be added to the quote if necessary once a path
forward is chosen and pre -bid site visits are made). We would recommend using Garness Engineering
for the design and permitting. As noted above, tank replacement would supersede any repairs.
ARM Septic is committed to helping you complete repairs on your budget and timeline to bring your
system up to health. Please don't hesitate to reach out if you have any questions or concerns.
Thank yougty Nat
haniel anberg
Septic Technician
ARM Septic Services
17933 Old Glenn Highway "Chugiak, AK 99567
office: (907) 688-9433 Email: ARMServicesAK@outlook.com
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241072, Curtis Townsend, 05/13/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241072, Curtis Townsend, 05/13/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241072, Curtis Townsend, 05/13/24
■
I
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this Day of of 20 by and between
Ka w- n wa here' the "OWNER," and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as �.WA►r-ly { (1r,
located at (legal description)
2. Maintenance, Repairs and Alterations.
(Owner is required to read, understand and initial each section)
- Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
f ` It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
C-L Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
�� Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. OS/18/2018) Pagel of 3
�-- Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
1C Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
OWNER:
By: ignature)
� a0Ant name)
STATE OF ALASKA )
ss.
THIRD JUDICIAL DISTRICT )
Date: �L! A�x I
The foregoing instrument was cknowledged before me this j day of A ,
20 t, by ('ClM?!/�i�t �tie��'1 S
NOTARY PUBLIC FOR ALASKA
My Commission expires: Im 2 64 2 OZ-9-
MUNIGYALITY:
1
By: (signature)
C D (print name)
CAMERON A. WILLIAMS
Notary Public
State of Alaska
My Commission Expires Jan 26, 2027
Date: 5 / 3 20 Z
Title: CAVIL
(rev. 05/18/2018) Page 3 of 3
vlrawvn ■ ■ 19-S
APR 2 6 2012
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water & Wastewater Program
4700 Elmore St. a P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite a (907)343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP121D35 PID Number: 015-271-60 ❑ New ®Upgrade
Name: KAREN CUSHMAN
ABSORPTION FIELD
❑ Deep Trench ❑ Shallow Trench ®Bed ❑Mound
Address:
4645 MANYTELL AVENUE *ANCHORAGE, AK 99516
❑ Other
Phone: No. of Bedrooms:
Soil Rating:
Total Depth tram original grade:
(907) 345-4571 4
4.0 GPD/Sq. Ft.
1.04 Ft.
LEGAL DESCRIPTION
Depth to pipe Invert tam original grade:
SEE DWG. Ft.
Grovel depth beneath pipe:
0.51 Ft.
Subdivision: Block: Lot:
Fill added above original grade:
Gravel length:
TIMBERLUX #3 G 6
SEE DWG.
25
Ft.
Ft.
aWn3 Ip: — anger — Section: —
Grovel width:
seds Number of linea
Distance between lines:
10 Ft.
2
5 Ft.
SEPARATIONDISTANCES
Total absorption area:
250
umber of trenches:
—
Dist. between trenches:
—
T°
Septic
Absorption
Lift
Holding Public/Private
rom
Tank
Field
Station
Tank Sewer Lines
SQ. Ft.
Ft.
Well
EXISTING
100'+
EXISTING
— 25'+
TANK ❑ Septic ®S.T.E.P. ❑Holding ❑Other
Manufacturer:
capacity.
Surface Water
EXISTING
100'+
EXISTING
—
EXISTING
Gal.
Lot Line
EXISTING
10'+
EXISTING
— N/A
Material:
Number of compartments:
Foundation
EXISTING
10'+
EXISTING
-
LIFT STATION
Curtain Drain
NONE KNOWN
Manufacturer:
Capacit,
EXISTING
Gal.
Remarks: OLD BED WAS REBUILT
"Pump on° level at:
Pump otF level at:
HI er alarm at:
ALL OTHER COPONENTS OF SEPTIC SYSTEM WERE LEFTPump
Make &Model:
ctncal Inspections performed by.
IN PLACE AND IS BEING UTILIZED.
PIPE MATERIAL
House to tank EXISTING Tank to EXISTING
drainfield
Installer
A+ HOME SERVICES
Drainfield D3034 CO/MT D3034
Inspector GEG, Ltd.
BENCH MARK (Assumed elevation)
98'94 Ft.
Inspection
Location and Description:
2nd 12 5 4 5 12
Dates: 1St 4 /
/ / /
3rd 4/6/12 4th
BOTTOM TRIM SW CORNER OF HOUSE
Community Development Department Approval
ENGINEER'S SEAL
oo F
4
o OF a�
Conditional approval: Date:
;' H v 0
':.. D
...................
D
p....:..........................p
'A •.d r A. Go ess: Q
�
4o4f^,...���I�2
Approved: /2 A-01
•...coo
Date:
4pof
QQo=oma
A
PERMIT NUMBER: PARCEL ID NUMBER:
OSP121035 AS -BUILT DRAWING 018-271-60
10' DRAINAGE & UTILITY EASEMENT
/
/
/
� I
\ I 700 WELL RADIUS
�\ I
� I
l
\\ 1
\ 1
\ MT2 \
\ CO2q- \ C
\\ / F07 \\ EXISTING 4 BEDROOM HOUSE
IIVENT �
I aMT1 \
\00 HH \
I VCEaJT
I C
70p• I
v
f EXISTING 2000 GALLON STEP
TANK & TRICKLING FILTER.
/ P
/ SCP
GARNESS ENGINEERING GROUP, Ltd..
,„ ......._...._.��___.— CONSULTANTS & GENERAL CONTRACTORS
1 E. NOOR RMO, SME 101 • MICMOWC Mt 99507 • PRONE (807)337-81)9 • FM (90'p3b M3 • WFB : v�w.9amwwn9i9rfin9.mm
lEPARED FOR: PHONE NUMBER: PAGE NUMBER:
KAREN CUSHMAN 345-4571 3 OF 3
GAL DESCRIPTION: DRAWN BY:
TIMBERLUX #3; BLOCK G, LOT 6 1 PNB
:TYPE OF WORK:
AS -BUILT DRAWING 4/9/12
(Rev. 01105)
oll!11,11"m
N
C3
O
J
A
B
C
C01
38.79
X9.65
MT1
j571..94
5854.095
53
CO2
6.10
42.79
44.14
MT2
57.14
44.11
45.03
/
/
/
� I
\ I 700 WELL RADIUS
�\ I
� I
l
\\ 1
\ 1
\ MT2 \
\ CO2q- \ C
\\ / F07 \\ EXISTING 4 BEDROOM HOUSE
IIVENT �
I aMT1 \
\00 HH \
I VCEaJT
I C
70p• I
v
f EXISTING 2000 GALLON STEP
TANK & TRICKLING FILTER.
/ P
/ SCP
GARNESS ENGINEERING GROUP, Ltd..
,„ ......._...._.��___.— CONSULTANTS & GENERAL CONTRACTORS
1 E. NOOR RMO, SME 101 • MICMOWC Mt 99507 • PRONE (807)337-81)9 • FM (90'p3b M3 • WFB : v�w.9amwwn9i9rfin9.mm
lEPARED FOR: PHONE NUMBER: PAGE NUMBER:
KAREN CUSHMAN 345-4571 3 OF 3
GAL DESCRIPTION: DRAWN BY:
TIMBERLUX #3; BLOCK G, LOT 6 1 PNB
:TYPE OF WORK:
AS -BUILT DRAWING 4/9/12
(Rev. 01105)
oll!11,11"m
N
C3
O
J
PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER:
-
OSP121035 018-271-60
NAL GRADE
= 96.96+
QF_.SAND IN
GINAL BED WAS 92.87
Of NEW SAND= 93.22 r
FABRIC
OF ORIGINAL
ORGANICS
=94.26
'.'.'MOA AP PRO VED SAND..'
INVERT OF DISTRIBUTION
10' WIDE LINE = 93.73 (AVG.)
BOTTOM OF
EXCAVATION
= 90.59
(AVG.)
_006000
0 4
0
GARNESS ENGINEERING GROUP, Ltd,* .. 4
..r*I
.,�:-; CONSULTANT'S & GENERAL CONTRACTORS==: .,, _ .,:- .. , _..�. . . ....... ........
3701 E NWR ROA. Win 101 • ANCHORA M 99507 • PHONE (907)337-61)9 • FAX (907),336-32M • NE M www.9ornc®mgln=Nn%com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: •• •• .. ....... .......
KAREN CUSHMAN 345-4571 2 OF 3 Qp ''., f A. ess;
LEGAL DESCRIPTION: DRAWN BY: V 9. CE -795 m�G
TIMBERLUX #3; BLOCK G, LOT 6 PNB NVQ�•i�.2 ca��
TYPE OF WORK: DATE:
PROFILE AS -BUILT DRAWING 4/9/12
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121035
Tax Code Number: 01827160000
Work Type: Septic Upgrade
q/�/Z 12:310
Permit Effective Dates: March 27, 2012 to March 27, 2013
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: TIMBERLUX #3
Site Legal Address: TIMBERLUX #3 BLK G LT 6 G:3136
Owner/Address: CUSHMAN CHARLES R & KAREN L
4645 MANYTELL AVE ANCHORAGE AK 995164122
Site Mailing Address: 4645 MANYTELL AVE, Anchorage Lot Size in Sq Ft: 56400
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By:
re i?ti(1� r lEli�I-
_1911'YN�w�
�l lwte u�a,�itw�jr �Er �ezr �"� (r+�fss
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program
Mayor Dan Sullivan
On -Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. 018-271—
Property owner(s) KAREN CUSHMAN Day phone 345-4571
Mailing address 4645 MANYTELL AVENUE *ANCHORAGE, AK 99516
Siteaddress 4645 MANYTELL AVENUE *ANCHORAGE, AK 99516
Legal description (Sub'd, Block & Lot) TIMBERLUX #3; BLOCK G LOT 6
Legal description (Township, Section & Range)
Lot Size
Sq.Ft.
Number of Bedrooms
4
THIS APPLICATION
IS FOR:
THIS APPLICATION IS AN:
(®all that apply)
Initial
❑
Absorption Field
®
Septic Tank
®
Upgrade
❑
Renewal
❑
Holding Tank
Privy
❑
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 14 JJU Waiver Fees:
Date of Payment: 3'ZZ IZ Date of Payment:
Receipt Number: 6 n 40 56
Permit No. 0 5 P 1 a l[ 0 55
Receipt Number:
Waiver No.
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
May 7, 2012
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907)343-7904
Ref: Timberlux #3; Block G, Lot 6, Request to Amend Permit OSP121035
To whom it may concern:
It has come to our attention that the existing upflow filter is plugged and in a state of failure. We are
Proposing to remove the existing upflow filter and replace it with a new one. We are requesting that the
MOA amend the existing permit to reflect this change.
If you have any questions, please contact us at 337-6179.
.S.
Thank you for your assistance.
1� 13 M1
u�lO�Li�c.J(s
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengincering.com
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
April 5, 2012
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907)343-7904
Ref: Timberlux #3; Block G, Lot 6
To whom it may concern:
It has come to our attention that it will not be possible to raise the sand height in the re -built drainfield to
an elevation that is 12 inches higher than the elevation of the existing top of sand. The limitation has to
do with the fact that the discharge line coming out of the existing upflow filter is fixed. If we remove the
sample port after the upflow filter, we can raise the height of the drainfield a maximum of four (4) inches.
I would argue that the height of the existing drainfield has adequate separation (4 feet) to seasonal high
groundwater because the design was based upon groundwater monitoring perforrr�ed by Lou Butera, RE,
during May of 1995. Butera monitored groundwater in TH #1 between 5/17/1995 and 5/26/19995 and it
varied between 5.8 feet and 6.0 feet below grade. The proposed top of sand in the re -built drainfield will
be 1.6 feet below the top of original grade. In short, the proposed top of sand will be greater than 4 feet
above the seasonal high groundwater table. An additional factor of safety in the design is provided by the
fact that effluent from the RUF system is passed through over 3 feet of sand in the existing upflow filter
before being discharged to the drainfield.
We are requesting that the MOA amend the permit to allow for the drainfield top of sand elevation (in the
rebuilt drainfield) to be raised to an elevation that is only 4 inches higher than the top of sand in the
existing drainfield.
If you have any questions, please contact us at 337-6179. Thank you for your assistance.
M.S.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
March 20, 2012
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907)343-7904
Ref: Proposed Septic Upgrade for Timberlux #3; Block G, Lot 6
To whom it may concern:
The existing 4 bedroom house is served by a private well and an Orenco "Reactex" septic system. The
drainfield is in a state of failure and needs to be upgraded. We are proposing to rebuild the existing
drainfield and re -utilize the existing 2000 gallon S.T.E.P. tank and existing trickling filter. The proposed
re -built bed will be 10 feet wide and 25 feet long (same as previous install).
1. SOILS: See the 1995 Louis Butera, P.E. soil log (attached) which shows the soil classifications,
groundwater monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There is a road ditch to the south of the property which runs along Mannytell
Avenue. The proposed re -built drainfield will be installed greater then 100' from this water source..
4. TOPOGRAPHY: As can be seen on the attached design drawing the topography around the
drainfield is relatively flat. In short, there are no slope concerns.
Ground water monitoring (G. W.M.) from 1995 was at 5.8 feet below grade. After the contaminated sand
is removed, MOA sand will be imported and built to an elevation equal to the existing top of sand.
We are unaware of any adverse impacts this installation and granting of the waiver request would have on
adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you
for your assistance.
NOTE: Attached is a site plan drawing and a design drawing, which are all part of the design package
for this septic system. (Contact G.E.G. Ltd. for 7page construction specification letter.)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
NUMBER OF BEDROOMS: 4 rr GALLONS PER DAY (GPD): 600
PERCOLATION RATE/S: •9.311
PROPOSED APPLICATION RATE: w*4
MINIMUM DRAINFIELD SO.FT.:150
APER PREVIOUS DESIGN AND INSTALL
MAXIMUM DEPTH: REMOVE ALL CONTAMINATED MA
WIDTH: 10'
LENGTH: 25'
M.O.A. APPROVED SAND FILTER: SEE NOTE #1
EFFECTIVE: 0.5 FEET
REDUCTION FACTOR: N/A
ACTUAL SO.FT.: 250
LETTER THAT PERTAINS TO THIS DESIGN.
TO OBTAIN A COPY OF THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
CONDITIONS OUTLINED.
NOTE g1: 10' x 25' EXISTING
DRAINFIELD PROPOSED TO BE
RE -BUILT AT 10' X 25'.
REMOVE ALL CONTAMINATED
MATERIAL AND IMPORT MOA
APPROVED SAND.SAND
LEVA TO BE
SAN THE ELEVATION OF
THE EXISTING TOP OF SAND.
MTC
I
'oo• I
i
i
i
i
10' DRAINAGE & UTILITY EASEMENT
MOUND MUST HAVE 3:1 SLOPES. IN
ADDITION, THE MOUND SHALL BE
_TATED AFTER SPRING BREAK-UP 201
/
/
/
/
/
I
_ 100' WELL RADIUS _
EXISTING 4 BEDROOM HOUSE ~o
\ J
H
d T
Go VE
— —
-EXISTING 2000 GALLON STEP _
TANK & TRICKLING FILTER TO
BE REMAIN AS IS. I •.. ° I�
MANYTELL AVE.
GARNESS ENGINEERING GROUP, Ltd. ✓* ; 4 -'7*
_.. ,.., CONSt9LTAPiTS &GENERAL CONTRACTORS _.. . • • • • • • . . . ..........
3701 E. RIDGR ROAD, SUITE 101 ANCHORAGE. AK M07 • PK E (907)337-8179 * FAX (907)338-3248 r MOM: www.9amemmglncerin9.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
KAREN CUSHMAN 345-4571 2 OF 2 y arness.•
AL DESCRIPTION: DRAWN BY: VU�9i •�/ CE
TIMBERLUX #3; BLOCK G, LOT 6 PNB QQew.•.
e
OF WORK: DATE: 04a'olof1
DESIGN UPGRADE FOR SEPTIC SYSTEM 3/20/12 004
I Municipality of Anchorage Page I of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ,5LJ9800sI PID Number: 015- Z.-71 — 610
Name:GiLES 4 KAR£'J Gush M AiJ
Wastewater System: ❑ New XUpgrade*
Address:
N1Ar✓Yr>:+<— Ave. F1rJua. AY_ 91614
ABSORPTION FIELD
Phone:
$ —11390/2-L7—OL/'7 to
No. of Bedrooms:
4❑Deep
I
Trench ❑Shallow Trench .� Bed ❑Mound $Other
LEGAL DESCRIPTION
Soil Rating:
0PPI.1cATrI 441Ti
Total Depth from original grade:
3'-**
GPD/Sq. Ft.
Lot: Block: subdivision:
G G
Depth to pipe bottom from original grade:
G ravel depth beneath Pipe
0.5
11 O)e
1' —I.s' Ft.
Ft.
Township:
Range:
Section:
Fill added above original grade:
Gravel length: 1
1 -. 15 CA:Y6R f Ft.
'ZS Ft.
WELL'New ❑ Upgra a
Gravel width: 1
1
Numberoflines:
:Z
Distance between lines:
I S
CXIS7
Ft.
Ft.
Classification e, ABC): Tot
Cased To:
Total absorption area:
Pipe material:
PKI 0%,re Ft.
Ft.
2$O SC. Ft.
A Td1 0-3034 Edlo
Driller. Drillad j
Static Water Level:
Installer: A+
Sff
Date installed: S/ZI /9$
Ft.
-es
Yield:
Pump Set at:
Casing Heg eGround:
TANK
GPM
Ft.
Ft.
SEPARATION
DISTANCES
❑Septic ❑Holding WS.T.E.P.
TorTantk
Absorption
Lift
Holding
Public/Private
Manufacturer:
Capacity in gallons:
From
Field
Station
Tank
Sewer Lines
fs� RA(� T /:k.
well
1107'±
115'1
—
75
Material:
STee�
Number of Compartments:
wafers
1oo`t
loo'+
LIFT STATION
Lot
Line
371±
1
58 f
�-
Size in gallons:
2000
Manufacturer:
rir-4MA6E Td� 02 a .SYS.
Foundation
��
(Pump
20tH1
on" level at:
a
"Pump off'level at:
kt
High water alarm at:
of
-t
4
y'4Curtain
Drain1Jo
iGNa
Pump Make & Model
(�t)aSt3NFIF
Electrical Inspections performed by:
M. 0. A -
Remarks: ?' Is A
BENCH MARK
T SE nc CVJ
Location and Description:
19 &ICA INAIC= TOP OF DE GIC AT
Stir NJo UPELoW Fi Lre2.
Pe to r " R"
alE 1 �+ OF S is 100e0
Assumed Elevation:
/Oo.o
ENGI`F111; AL
OF q��stl1
Inspections performed by: ��jes:ls 5 t9 �s
��••� eeeeee..
7320 East Chester MS- Circle 2nd S/lela8�k`
• • t
k. JA�ME'S P. YYILI,IAMS
Anchorage, Alaska 99504 3rd s t ge
c •, NO. VAS
Department of Health and Human Services approval
ito
Essio�����..
Reviewed and approved by: &4111—eh; /964* Date: _7 6` 14
72-013 (Raw. 9/91) MOA 25
PERMIT NUMBER: AS -BUILT DRAWING PARCEL 10:
SW980051 018-271-60
A B ___
VENT#21 47.25 23.5 ��' ���
C01 46.5 23.75
MH1 46.0 25.5
MH2 44.5 30.8 1/
SP 58.75 51.3
VENT#3 60.25 52.5
CO2 39.551.5
MT1 54.0 50.5
CO3 44.5 56.0
MT2 42.5 53.5
I
__
----------
100'
100' WELL RADIUS AWELL
ALTERNATE SITE`
\
\��
NEW 10'x25' BED
i 2
02
� n `
'oRT`("s ANG
P i H t'
/ �(%s Oti1
NEW UPLFOW FILTER
VENT#3 f .
/1 HH1
I
YEtiTM2
I o11,
WELL
i
�APPRwu 100
LOC -71,
1 --
nn
1
CO -- ---_
AIR VENT
/ EW 2000 GALLON < `
/ RECIRCULATING
i / SEPTC TANK
i
� rlwe
i
i
i
i
i i i
PREPARED ALASKA WATER & WASTEWATER 0
dPE C3F �j:9_`S�pp
Q
%•4Q
LEGAL DESCRIPIGN:
'T 9
TIMBERLUX SUBDIVISION #3, LOT 6, BLOCK G, ............
TYPE OF WORK:
AS -BUILT OF SEPTIC SYSTEM UPGRADE (R.U.F. SYSTEM)U�111>Y's.. ••• ••••
LIA r
.JAMES
PREPARED FOR: PHONE NUMBER:oOo o '.• NO. 9608
KAREN CUSHMAN 345-1890/227-0476 a C.E. ;
mm. 5/28/98 DRAWN J.L.M. s 1 = 40' PAGE --2 OF 3 4�e�prfesslo�o
PERMR NUMBER: AS -BUILT DRAWING PARCEL 10 271NUMBER.
SW980051 GRp p 018-271-60
FINALGIN NRADE =9fi 21 f R� 2 INCHES OF
iuN n ES OF
1 1/4
it
91
NAL GRADE
96.79
ORIGINAL GRADE
NORTH END = 95.54
SOUTH END = 95.21
CO3 = 94.12 t` oFILTER" CO2 = 94.12
TOP OF SAND FILTER
93.62 SAND LEVEL
MT1 = 93.62 BOTTOM OF SAND FILTER
NORTH END = 92.62
SOUTH END = 92.04
:PARED BY:
ALASKA WATER & WASTEWATER
TIMBERLUX SUBDIVISION X13, LOT 6, BLOCK G.
E OF WORK:
AS—BUILT OF SEPTIC SYSTEM (PROFILE AS—BUILT)
PARED FOR: PHONE I
KAREN CUSHMAN 345-1
E: DRAWN BY: SCA c.
5/28/98 J.L.M. N.T.S.
—0476
3 OF 3
NO. 9606
C.E.
f,— I Ck i r t f : 31 FR1 FRl)Id 'AF2GT i T
1,M -ITS EL.E(f7 ? d5 6181 `
...
'Vlip
ak F 7v
f�iupaClPA'url OF ANCHORAGE, BUILDING ✓AFE'!'Y DIVISIQ�'
1st
3500 .EASIT TIMOR ROAD
u ocnTrnni• �r, r.a raa.aeae fMQPrn•r!nAl• PAX (9071 342,M5 lFaF't'3
4 A -,No NUNWfWPLIAWE 0BUERVEl7 n
�
TIALS AS ESCR AWED F*LOW ] CURREC71OiVS ES3EN . _
t 1 •fL1. NEEXAiuiiN�z._��.JI�:EE�I.LQN.,L� f�fd'C C-CfJCE�L UtVTIL REIA„'°
A
COMI AENTS.
f 4. Iry x/ flv
l �u J N 51`x' % i
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE gpyyl
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502 zj fj.i9.Cf (o
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW980051 DATE ISSUED: 4/03/98
DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES EXPIRATION DATE: 4/03/99
OWNER NAME:CUSHMAN CHARLES R & KAREN L
OWNER ADDRESS:4645 MANYTELL AVE
ANCHORAGE, AK 99516
PARCEL ID:01827160
LEGAL DESCRIPTION:
TIMBERLUX #3 BLK G LT 6
LOT SIZE: 56400 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THIS IS A PERMIT FOR A RECIRCLUATING UPFLOW FILTER SYSTEM.
A SAMPLING AGREEMENT SHALL BE SUBMITTED TO THE MUNICIPALITY
BEFORE THE SYSTEM IS GIVEN FINAL APPROVAL.
RECEIVED BY:
DATE: y/- 3 - gg
ISSUED BY: //Li�i�// / /�G�if/�J DATE: �'J S. %�
Alaska Water & Wastewater
Agby
7320 East}I16du g0ENVI0LER01i;TAPhone(907) 337-6179e Fax (9Anchorage3$ 32$JiCFSQ�4s"O'y
Consulting Engineers MAR 9j 1998
ECEI11F1)
March 16, 1998
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On -Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Septic System Upgrade for Lot 6, Bk G, Timberlux S/D.
RECIIiCULATING UPFLOW FILTER (RUF) SYSTEM
To whom it may concern:
1. GENERAL: The existing 4 bedroom home is served by a private septic system and well.
The existing bed system is encroaching groundwater and surface water and must be upgraded. A
septic upgrade permit (SW950249) was issued by your Department in August of 1995, however
the proposed upgrade was never installed. The owner has now requested our firm to redesign a
septic system which would allow for a smaller leachfield than the previous design. We propose to
install a Recirculating Upflow Filter (RUF) system as designed by Anchorage Tank & Welding.
In May 1995 three test holes were excavated and soil percolation tests performed by Eagle River
Engineering Services. The original soil logs are on file in your department (see attached copies).
The soils are summarized as follows:
2. SOIL CONDITIONS: Per Municipal records three test holes were excavated on May 16,
1995 to an average depth of 8 feet. he soils profile for TH #1 consists of 2.5 feet of organics
(mainly fill and topsoil) followed by a GM material. Groundwater was encountered during the
excavation at a depth of 6 feet, and was monitored at the 5.8 foot depth ten days later. A
percolation test was performed between the depths of 3.0 and 4:0 feet and the absorption rate was
measured at approximately 9 minutes/inch (see attached soil logs).
3. DRAINFIELD: The intent is to install a Recirculating Upflow Filter (RUF) system that will
allow the use of a small drainfield in the area of TH 41. The size of the drainfield will be based
upon the previously established criteria for the RUF systems, which dictates that soils percolating
between 1 & 30 minutes/inch have an allowable appli4kion rate of 4 gpd/ft2 and soils percolating
between 30 &. 60 minutes/inch have an allowable application rate of 2 gpd/0. Given the perk
PNVlRNICIP
C Alliyal; .
NMTNTgt SFRv e"S 0RA UE
tCN
MAR 23 1998
rate of 9.3 minutes/inch the 4 gpd/ft2 application rate would apply. We are proposing to install
10 foot wide bed that is 25 feet long and has an effective depth of 6 inches. This corresponds to
an absorption area of 250 ft2, or an application rate of 2.4 gpd/ft2 (assuming 600 gpd total flow).
4. ORENCO PACKAGE SYSTEM: The STEP tank with the trickling and upflow filters will
be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by
Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. Since you are
familiar with the operation of the system I won't elaborate. As with their standard STEP tank, it
is equipped with a high water alarm per M.O.A requirements.
5. SURFACE WATER: There is a surface water source within the road ditch which flows east
to west along Mannytell Avenue. It has been previously determined by the Municipality that the
water which flows within this ditch is definitely surface water. The proposed upgrade is designed
to be installed greater than 100 ft. from this water source.
6. TOPOGRAPHY: The slope of the ground at the proposed upgrade site is basically flat (less
than 2%). There are no slopes greater than 25% within 50 feet of the proposed bed.
7. CLOSING: I am open to any suggestions from your department that would be an
improvement to the proposed system. I am unaware of any negative impacts that this installation
would impose on adjacent wells, or septic systems. If you have any questions, please call me a
337-6179, or 244-9612.
S' cerely,
James P. Williams, P.E.
Civil Engineer
•
10' DRAINAGE & UTILITY EASEMENT twplP�L+TI`IIr
•
------ - ------- _ - —'- - — - --- - '-- — ` — - —`
;4tal
'
r'l
PROPOSED DRAINFIELD� INSTALL 10' WIDE, 25'
LONG BED, USE 1,0' SAND FILTER BELOW
DRAINROCK. (SEE DETAIL DRAWING).
CONTRACTOR SHALL HAVE ADJACENT
WELL RADII LOCATED (FLAGGED) PRIOR
TO CONSTRUCTION.
-
LOT 6 AI OX• cunk-r4dt-1 02"N
OGIbTIJr•+ {SCR. OWNcb�
L
REPLACEMENT
1.25' DIA, NAE
SITE 10'x25'
(SEE ➢ETAIL D
NEW
`` /O ADDrTrpN
LOT 7
(TYP)
a�
n
exrs
°k TING
a T
rHn! 4 B.pRM
(TYP HSE.
WELL
��,
SAMPLE PORT
UPFLOW FILTER PER`:'
'
ANCH. TANK DESIGN'
r"l INSTALL FCO:I__' _
NEW STEP TANK WITH
RECIRCULATING FILTER
4' DIA. ASTM D3034 SOLID PIPE -
SLOPED AT 1/4' PER FOOT
THR2
EXISTING SEPTIC SYSTEM ORIENTATION
AND LOCATION PER MDA RECORDS...
AND FROM 1994 AS -BUILT SURVEY.
<,,,.
(TO BE PROPERLY ABANDONED PER
UPC) i"-'
1;NOTE ENSURE 100' MIN. SEPARATION BTWN. SEPTIC
AVE.
�ooQF ^ 0�4
UPGRADE AND SURFACE WATER WITHIN ROAD DITCH. MANYTELL
o ..
SEPTIC UPGRADE, TIMBERLUX #3, LUT 6, BK G
;' 4
PREPARED FOR! KAREN CUSHMAN
..!. . •• •••.......... •••
P ;James P.Williams;
a CE -9608
ppe
PREPARED BY ALASKA WATER & WASTEWATER
��tlpro fesslo���
DATE+ 3/16/98
DRAWN: WILLIAMS
SCALE 1° = 40'
MIN COVER = 2 FEET.
SLOTTED PVC PIPE.
4 INCHES OF BLUEBDARD
OVER TOP OF FILTER,
DRAINROCK FROM TOP OF BLOCK PEA, TO
2 INCHES OVER TOP OF SLOTTED PVC PIPE.
MANHOLE LID (TYP.)
X
�
O
6
i9, r
Yy>,,_
76' DIA.
`2.5 FEET MIN OF ANCHORAGE
SAND AND GRAVELS 'BLOCK PEA'.
INFILTRATOR CHAMBER (12 INCHES TALL)
ON BOTTOM OF TANK IS COVERED WITH
MIN. OF 2 INCHES OF DRAINROCK. BOTTOM
OF BOX TO BOTTOM OF BLOCK PEA IS
APPROX, 15 INCHES.
BAR 23 199'8
"EcElllpl�
NWITH RECIRCULATING TRICKLING EW 2000 GALLON STEP TANK. 14 IN
DIA, PVC
FROM HOUSE.
FILTER, PER ANCHORAGE TANK DESIGN.
SET TANK LEVEL
1.25 INCH DIA. HDPE PRESSURE LINE
FROM STEP TANK. CHECK VALVE
IN STEP TANK PREVENTS BACK-
FLOW TO TANK. MIN BURIAL DEPTH
OF 4 FEET, AND 4 INCHES OF INSULA-
TION BOARD (2 FEET WIDE) OVER THE
TOP OF THE PIPE, FOR EFFECTIVE
BURIAL DEPTH OF 8 FEET.
NOTE, THE UPFLOW CHAMBER SHALL BE INSULATED WITH 2'
OF SPRAYED URETHANE, BY ANCHORAGE TANK.
SEPTIC UPGRADE: LOT 6, BK G, TIMBERLUX #3 S/D.
PREPARED FOR+ KAREN CUSHMAN
ALASKA WATER & WASTEWATER CONSULTANTS
DATE: 3/16/98 1 DWN+ WILLIAMS I SCALE; NTS
49
,James P. �lIliams;
CE -9608 ,
ENTIRE AREA OVER DRAINFIELD SHALL BE TOPSOILED AND RESEEDED,
2 FOOT MIN. COVER OVER TOP OF ➢RAINROCK.
4 INCH DIA. DRAINPIPE. LAID LEVEL WITHIN .01 2.5'
2.5' FEET. PROVIDE 6 INCHES OF CLEAN DRAINROCK
CAS&G) BELOW PIPE, AND 2 INCHES OVER TOP.
3,1 SLOPE
MAX. Cep PROVIDE FILTER FABRIC & MT 3Q SLOPE
Tr
n T INSULATION OVER TOP OF DRAINROCK. n MAX.
REMOVE TOP 36 INCHES OF SOIL. LEVEL WITH 12'+ OF SAND AS REQUIRED.
SAND SHALL BE CENTRAL PAVING PRODUCTS 'WINTER ROAD SAND' OR APPROVED EQUAL.
25 FEET
FOR LOCATION OF CLEAN -OUTS AND MONITORING TUBES, SEE THE 40 SCALE SITE PLAN.
A. BED LENGTH = 25 FEET
B. BED WIDTH = 10 FEET
C. TOTAL ABSORPTION AREA = 250 SQ. FT,
D. MAX. DEPTH OF EXCAVATION = 3 FT.
E. MIN. DEPTH OF FILTER SAND = 1.0 FT,
MT
I.- - FILTER -SAND, 'I.- '., I
2.5 --1 5.0
10.0
2.5
SEPTIC UPGRADE: LUT 6, BK G, TIMBERLUX #3 S/D.
PREPARED FOR: KAREN CUSHMAN
ALASKA WATER & WASTEWATER
DATE 3/16/99 DWN, WILLIAMS SCALE1 NTS
ASTM D3034
5 FT. LONG
4 INCH DIA.
MANIFOLD
ASTM F810 PERF PIPE, 20 FT. LENGTH CTYP)
3,1 MIN.
m
,James P. Williams;
CE -9608 ,
e,. ..... . °9-
Municipality of Anchorage
Department of Health and Human Services -
825 "L" Street MUNrCiPAhr
RickMayot(om, P.O. Box 196650 Anchorage,
Alaska
las a99519-6650htiFNV�RA� cH1A(gg��� s pf�r�lUy
Dear Homeowner/Prospective Buyer: MAR 2 3 1998
The on-site wastewater disposal system you are purchasing/installing is an "alternative&cfi#, F
disposal system. This system, known as a "Recirculating/Upflow Filter Septic System", is undergoing
testing within the Municipality of Anchorage under the Alternative System section of the Wastewater
Disposal Regulations (AMC 15.65). There are certain risks involved with the ownership of one of these
systems:
1. The technology used in this system has been shown to be effective in other areas. The system is
currently undergoing a two year testing period in Anchorage under the guidance of the Department of
Health and Human Services (DHHS) and the State of Alaska Department of Environmental Conservation
(ADEC) to determine its effectiveness in a subarctic environment.
2. The system for this property received a vertical separation distance waiver from both State of
Alaska and Anchorage Municipal Codes to ground water. This waiver was granted due to the system's
expected performance within the site conditions on this property.
I (we) certify that I (we) have read the above statements and am (are) aware of the risks outlined. I (we)
also certify that I (we) am (are) in the process of purchasing (property legal description):
c6tdes P-6as k ��
(Purchaser Signature)
Notarize Here
ate,, i �N kA LOLI
(Purchaser Name)
1-� 14 d. OA
(Purchaser Signature)
State of "C V34–a— n.
On this l q4k-\ day of v3YUII`
,
(2�nar les + K0Lx en CuQ,4t�han personally appeared before .me,
who is personally known to me
whose identity I proved on the basis of 4afl)(–
whose identity I proved on the oath/affirmation of
, a credible witness
to be the signer`of the above document, and he/she acknowledged that he/she signed it.
Notkt5tublic
My commission expires My Commission Expires
March 40, 1999
M
PROPERTY OWNER AGREEMENT
FOR THE MAINTENANCE OF AN
ON-SITE WASTEWATER DISPOSAL
SYSTEM
MAI? 2 3 1598
This agreement, dated 199.a, is made between the Muni
Anchorage Department of Health and Human Services (DHHS) and the prop ��F11
owner(s) of: R .4
This agreement is made for the purpose of maintaining an on-site wastewater disposal
system on the subject property.
The property owners agree to the following:
Submit to the Municipality of Anchorage, on an annual basis, an inspection and
operation statement from a registered professional engineer. This inspection and
operation statement shall verify that the engineer has inspected all effluent and air
pumps, timers, and alarms, and that any deficiencies have been repaired and that the
system is functioning as designed.
(Signature)
(Printed Name)
--------------------------------Notarize Here
(Signature)
(Printed Name)
State of 1%04*-O� On this Ig4k day of rno.XC, 1qq
RLLren 'I Qk10- -1eS Cl,�!'�personally appeared before me,
who is personally known to me y�
whose identity I proved on the basis of pQL.
whose identity I proved on the oath/affirmation of
a credible witness
to be the signer of the above document, and he/she acknowledged t at he s d it.
j
y Public
My commission expires yExpires
JUL-06-98 10:46 RM
SAMPLING AGREEMENT
P.02
The parties agree that Susan Oswalt & Associates (contractor) will provide monthly sampling
services for the Upflow Filter System installed on Lot 6, Block G, Timberlux Subdivision as
required by the Municipality of Anchorage, Department of Health & Human Services, during
the designated testing period.
At presentt the contractor will take samples from the outfall of the nitrate treatment apparatus;
however, changes to this matrix may occur. If any changes to the sampling arc required by
the Municipality, this agreement. will remain in force and samples will be collected as
required.
It is understood that the required testing period will be six (6) months. It is also understood
that although the cost of laboratory charges for this service will be borne by the
Municipality, the actual sampling labor costs will be borne by the property owner signing
this agreement. The cost of sampling will be at the rate of $45/hour, Additional services
provided for this system will be charged at the same rate.
The property owner agrees to keep sampling areas clear of snow and to provide reasonable
access to these areas, including access to any control panel within the dwelling. The
contractor will make every effort to give adequate notice to the property owner prior to
sampling.
This agreement may be terminated by either party with a minimum of ten (10) days' notice.
Dated;—1 "S -
(�? � l `iC0 lkt-lig
Signature of Property Owner Susan Oswalt & Associates
Alaska Water & Wastewater
7320 East Chester Heights Circle — Anchorage — Alaska 99504
(907) 337-6179 — Fax (907) 338-3246
Consulting Engineers
July 13, 1998
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On -Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Attn: Jeff Poet
:03
Ref Timberlux S/D, Lot 6, Bk G, Abandonment of Septic Tank.
Dear Mr. Poet:
RECEIVED
JUL 141998
Municipality of Anchorage
Dept. Health & Human Services
As required by the permit, the old septic tank on this property was abandoned. The tank was
pumped, the top ripped open, and the cavity filled with soil. If you have any questions, please
contact me at 337-6179, or 244-9612.
S' erely,
WDL"' es P. Williams, P.E.
vil Engineer
Munieipality of Anehorage
Department of Health and Human Services
825 "U' Street
Mayor Rick Myrom, P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
August 29, 1996
Charles R Cushman
Karen L Cushman
4645 Manytell Avenue
Anchorage, Alaska 99516 4122
Subject: Lot 6 Block G Timberlux Subdivision 03
Permit #SW950249, PID #018-271-60
The subject permit, issued August 29, 1995 by this office for a
single family well and/or on-site wastewater system, has
expired as of August 29, 1996.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as -built inspection report must be sent to this office for
review, approval and documentation. All inspection reports,
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
am Manager
to Services
enc: Copy of Permit
cc: Eagle River Engineering Services
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW950249 DATE ISSUED: 8/29/95
DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES EXPIRATION DATE: 8/29/96
OWNER NAME:CUSHMAN CHARLES R & KAREN L
OWNER ADDRESS:4645 MANYTELL AVE
ANCHORAGE, AK 99516
PARCEL ID:01827160
LEGAL DESCRIPTION:
TIMBERLUX #3 BLK G LT 6
LOT SIZE: 56400 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
AN IMPORTED SAND FILTER LAYER MUST BE INSTALLED TO
MAINTAIN A MINIMUM OF FOUR FOOT RTICAL SEPARATION
FROM A GROUND WAT: TABLE OF 5.p/ FT.W THE SOUTHG END
OF THE BED AND THE N 4_E OF THE BED.
RECEIVED BY;
ISSUED BY:
DATE:- 91-zl
DATE • ��
Louis Butera, P.E.
Registered Civil Engineer
August 23, 1995
Robbie Robinson
Manager, On -Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Timberlux #3 Lot 6, Block G
Dear Mr. Robinson:
We consider the drainage channel located on the above referenced property to be attributable to
snow melt, and therefore does not meet the definition of surface water which would require a
100' setback. The upgrade design utilizes a bed with a 2' sand filter and corrects a failing trench
system located in the groundwater table. We are going to recommend to the owner that an air
supply system be added six inches below the bed gravel in the sand layer to facilitate an aerobic
process. Please process the permit as soon as possible to allow construction this fall.
If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
\ G : \ W PD O C S \ 1995 \ 95-03 5A. LT R
P.O. Box 773294 • Eagle River, Alaska 99577 • Telephone (907) 694-5195 • Fax (907) 694-3297
MESIP, RIldQT EUSAIR AUS BCS TICICIT)
Louis Butera, P.E.
Registered Civil Engineer
June 28, 1995
Dan Roth
Manager, On -Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Timberlux #3 Lot 6, Block G
Narrative & Septic Upgrade Application
Dear Mr. Roth:
We are applying for a permit to construct an upgrade leachfield for the above referenced property.
This property has experienced continual problems due to changing neighborhood drainage
patterns.
We logged three test holes in the available septic area and found an acceptable receiving gravel
soil layer in two representative test holes, that may be usable for a conventional system with a
sand filter layer.
The permit request is for an imported sand filter layer over gravel with a varying water table depth
of one to two feet below native gravel soil as recorded during the high water level period during
break-up this season. The final separation distance to the water table will be at four feet vertical
distance utilizing sand fill. This is outlined on the attached profile drawings. Effluent delivery
will be pressurized and will utilize the OSI intermittent sand filter type control unit for a timed
dosing. The system is located on what we believe is the only area of the lot to have acceptable
soil In this position, we are located 60 feet from a seasonal drainage path that runs in the road
ditch. Tl cira-inage-w .Toni #Wyew! and was particyl riy,strong.due to the extreme run -
S d 29j1his seaA. &lWoDucnported1a be dry„ and therebore.,may not be considered a permanent
Aar cQminua1 drainage or surface water. requiring a 100 foot setback. ,The proposed leachfield
would have no affect on this drainage as is located on a level area at a higher elevation with no
possibility of surface run-off to the drainage course.
As this is an upgrade of an existing unsatisfactory system, reserve area is not a consideration. The
impact on neighboring systems is negligible and drainage patterns will not be affected.
If you have any questions please call our office at 694-5195. /
�/
,&� '
411-
Sincerely, ,
Louis Butera, P.E.
1GAWPD0CS\ 1995595-035A.NAR
P.O. Box 773294 • Eagle River, Alaska 99577 • Telephone (907) 694-5195 • Fax (907) 694-3297
SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM
LEGAL: Tbnberlux #3 Lot 6, Block G
06/23/95
A. GENERAL.
1. The septic uprade plan is for a single family residence only.
2. The drawing and or site plan shall be a part of this specification.
3. All materials and workmanship shall meet the Anchorage Department of Health
requirements.
4. All soil tests are advisory to the design and are to be verified or modified in the
field by the engineer.
5. All excavations and depths are advisory and are to be verified in the field by the
contractor to meet Municipality of Anchorage requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements
and to locate any adjacent multi -family wells.
7. The excavation is to be exactly in the area shown on the site plan, any deviation
requires engineer approval.
8. It is always recommended that a surveyor locate the nearest lot line position and
the location of any easements.
B. SEPTIC TANK WITH LIFT STATION
1. The septic tank shall be an Anchorage Tank 1,500 gallon septic tank with integral
OSI lift station pump model OSI-20-HHF and intermittant sand filter type
controller, SICTETMRO with programmable timer.
C. BED
1. The bed is to follow the natural land contour to maintain uniform total depth of the
bed bottom.
2. The bottom of the bed shall be level, plus or minus 1.5".
3. A 2' approved filter sand layer shall be required at a total depth of 6'.
3. The total depth of the gravel layer is not to exceed 4' at any point.
4. The effluent line is to be a 1-1/4" PVC line with 1/8" holes drilled 27-3/8" OC
within the leachfield, placed face up with orifice shields placed over holes. Line
from tank to field is to be 1-1/4" HDPE.
5. The bed gravel is to be covered with typar fabric material.
6. Soil or combination of soil and extruded board insulation to a depth of 3' or
equivalent is to be placed over the bed. Mounded side slopes not to exceed 3:1.
7_ The area over the bed is to be finish graded to prevent ponding of surface water
runoff.
8. The septic tank and leachfield must not be closer than 100' to any existing private
well, 150' to any Class "C" well, or 200 feet to any community well.
RECOMMENDED LEACHFIELD DIMENSIONS:
APPROXIMATE TOTAL DEPTH = 5' bottom of sand filter layer
SAND FILTER DEPTH = 2' of approved material
GRAVEL DEPTH = 6" under pipe, 2" over pipe
BED LENGTH = 57' BED WIDTH = 15'
SOIL RATING = 0.7 GPD/ft2 BEDROOM CAPACITY = 4
SEPTIC TANK = 1,500 with lift station
LEACHPIPE HOLE SPACING = 1/8" holes at 27-3/8" OC
Twenty-four (24) hours notice required for all inspections.
GAWPD0CS\1995\95-035A.SPC 1
15/8" REBAR
GRADE
TER FABRICo \�1-1/4' 45' EL
SEWER ROCK
000b'.LATERAL END
C o 0 0
PRESSURE PIPE CLEANOUT
A
2' PVC MAN'.
1-1/4' SCHED.40 PVC
1/8" HOLES 27-3/8"
WITH ORIFICE SHIELI
THi
1500
GAL
\
TANK
W/LIFT
�4'PVC
J k�3MJ.
WELL
q4'
PVC
4BR
NOUSE
ABANDON
EXST.TANK I
LEACHFIELD
® -
TEST HOLE
• -
MONITOR TUBE
o -
SEWER CLEANOUT
-0 -
WELL
-
CULVERT
— — — -
EASEMENT
—
rvicrinic i rA�Wru
Lu
rn
0
O
2
SEPTIC SITE PLAN (v1)
LEGAL: TIMBERLUX #3 LOT 6, BLK G = PAF OF
OWNER: CUSHMAN
CONTRACTOR: CUSHMAN * .4 TH
JOB # 95-035B DATE: 06/23/95 SCALE 1" = 50' i
EAGLE RIVER ENGINEERING SERVICES �j c LOUIS A. BU TERA � 0
;p CE -6736
P.O. Box 773294
EAGLE RIVER, AK. 99577 1111pROFES510NP ��
(907) 694-5195 FAX: (907) 694-3297 ������..��
NORTH END
OF BED
a ...m .' .v. N's)
WATER LEVEL
n w.m
SOUTH END
OF BED
LEACH BED TO BE EXCAVATED TO THE NATURAL
GRAVEL LAYER, APPROX. 97.2' ELEV. TO BE
BACKFILLED WITH APPROVED FILTER SAND TO AN
ELEVATION OF 100.06'.
BM = TOP OF REBAR AT SW LOT CORNER
BE® ELEVATT ONS (v2)oFwi%%
LEGAL: TIMBERLUX # 3 LOT 6 BLK G��;:••::.
OWNER: CUSHMAN
CONTRACTOR: N/A B.°"° ...•.... °
•ua a .. r...... .. •°°' �°
JOB # 95-035BDATE: 5/30/95 1 VERT. SCALE i° =10' Louis A.Bulera w
EAGLE RIVER ENGINEERING SERVICES 73
P.O.
P.O. Box 773294 �8F�p8�FESso���
EAGLE RIVER, AK. 99577
(907) 694-5195 FAX: (907) 694-3297
MEN
NORTH END
OF BED
a ...m .' .v. N's)
WATER LEVEL
n w.m
SOUTH END
OF BED
LEACH BED TO BE EXCAVATED TO THE NATURAL
GRAVEL LAYER, APPROX. 97.2' ELEV. TO BE
BACKFILLED WITH APPROVED FILTER SAND TO AN
ELEVATION OF 100.06'.
BM = TOP OF REBAR AT SW LOT CORNER
BE® ELEVATT ONS (v2)oFwi%%
LEGAL: TIMBERLUX # 3 LOT 6 BLK G��;:••::.
OWNER: CUSHMAN
CONTRACTOR: N/A B.°"° ...•.... °
•ua a .. r...... .. •°°' �°
JOB # 95-035BDATE: 5/30/95 1 VERT. SCALE i° =10' Louis A.Bulera w
EAGLE RIVER ENGINEERING SERVICES 73
P.O.
P.O. Box 773294 �8F�p8�FESso���
EAGLE RIVER, AK. 99577
(907) 694-5195 FAX: (907) 694-3297
EAGLE RIVER
ENGINEERING SERVICES SHEET NO.
P.O. Box 773294
EAGLE RIVER, AK 99577 CALCULATED
(907) 694-5195 CHECKED BY.
_ 0.
WWGTWH Ond SW4291
- 67
(ENGINEER'S SEAL)
e +r Municipality at Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: Co.S%,..•, ..✓ DATE PERFORMED: S,//6 /^73
LEGAL DESCRIPTION: //H•,6�r w,3 6 /G Township, Range, Section:
SLOPE SITE PLAN
F11 L
Pi I (FFe n
2 b.Pl6rN yL r+PtU>L
q qt I 3 -
I
1 4
5-
6-
7-
8-
9-
r 6 789
r
16
17
18
19
20
WAS GROUND WATER
ENCOUNTERED? YES
IF YES, ATWHAT 61
DEPTH?
Depth WWW After ��
Manilaring? Oat
aL
a
Reading
Date
Gross
Time
12
�e•,aeaes
ae. e•+•ease
13
0.
$89
Louis A. Butera e
°. 4
o
CE -6736
T e sj
14
ad
a��flFROFESSt���®
la.,,-„
;"4d "
/7/s
15
13, rr
16
17
18
19
20
WAS GROUND WATER
ENCOUNTERED? YES
IF YES, ATWHAT 61
DEPTH?
Depth WWW After ��
Manilaring? Oat
aL
a
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
for
..
o
l3: 43
la.,,-„
;"4d "
/7/s
13, rr
t n »: ,
3 146 .
„
S -/7-9f
,ti: a6
/O
3 Y16e
"hi
3
PERCOLATION RATE �° � (mmuteslmch) PERC HOLE DIAMETER
TEST RUN BETWEEN 3 FT AND 2 FT
COMMENTS
PERFORMED BY: E• R•£. S, 1 - CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: e/d- % ss
(ENGINEER'S SEAL)
e y° Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG - PERCOLATION TEST
PERFORMED FOR: Cu.r4'.N DATE PERFORMED: S//6 /9J
LEGAL DESCRIPTION: ///ii6esr Township, Range, Section:
TM ZT I( I�ISLOPEE SITE PLAN
E T U 1 I I
2
0
10
11
M� c/n y /r/Lr
CN QENSE ,ow!y
V
5:5° iGw}
Gro. ve/ �sgNn
i
12
S
61 QI
p
E
G _
i'A 9t
a •,
M!U ^ T
13
14-
Reading Date
V'
°Louis
16
���
A. 8utera
CE.6736
#&
. k° l
T'e°
7, rot.
°Oe°°.�
T7
aia:�ppn nclt ��t®
18
19
20
COMMENTS
WAS GROUND WATER
ee,r•nl.r Genf VF_S
III
11
IF YES, AT WHAT
DEPTH?
Depth to Water Mier
Monitoring? 5�S Batt
S
61 QI
p
E
G _
i'A 9t
v 1 _ ; &jo J.
Reading Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
Otr t
#&
. k° l
3 T,". s
7, rot.
7- f -79-4r
l3.Y0
yr?S"
7'(la
6"
!"
PERCOLATION RATE 7 (minutes/inch) PERC HOLE DIAMETER 6�
TEST RUN BETWEEN s'� FTAND %S— FT
PERFORMED BY: E'R'E't i -12�15"ss CERTIFY THAT/THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 6185)
(ENGINEER'S SEAL)
Municipality Anchorage
DEPARTMENT OF HEALTH &HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: of .x,4, •. DATE PERFORMED: S//6,9J
LEGAL DESCRIPTION: ! r/1'/ZL-r s/u x #m3 6 �G Township, Range, Section:
Tli 3 SLOPE SITE PLAN
FEETI ���
10
it
18-
19-
20-
COMMENTS
f`
���
2
m c /csr
3'
cc
4-
D e Nr C /
5-
56(G
see
$mm.
14
P
ip
..
6-
6�
a®^mm
(G w�
CE -6736
18
eD
�
8
17-
7
s
10
it
18-
19-
20-
COMMENTS
���
A fes`-�j•rta��
2
12-
F
13-
13see
see
$mm.
14
P
ip
..
15
6�
a®^mm
�.. .. ...,
r
Louis A. Burerc
CE -6736
18
eD
�
17-
7
181920COMMENTS
WAS GROUND WATER
ENCOUNTERED?
IF VES, AT WHAT
DEPTH?
yES
S
L
7 0
P
E
Depth to Waer Alter y6-
Manitarinpl C' I Oe1e: i = 45"
PERCOLATION RATE (mmuteWmch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
PERFORMED BY: E• R. t.S, I �'y"'� CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 57 dZZ LT
72.008 (Rev. 4185)
EAGLE RIVER
ENGINEERING SERVICES
P.O. Box 773294
Eagle River, Alaska 99577
(907) 694-5195
ERES Project No.: 95-035
Calculated By: LB
Date: 5/30/95
Single Family 4 Bedroom Dwelling
Bed Subsurface Wastewater Disposal Field
Water use at 150 gallons per bedroom =
Percolation rate =
Wastewater application rate =
Required absorption area =
Bed width (W) _
Gravel depth (D) _
600 gallons
<1 minutes per inch
0.7 gallons per day per square foot
857 square feet
15 feet
1 feet
Required length = Required absorption area / Bed width
Required length = 857 / 15
Required length = 57 feet
Total Excavation Depth = 4* feet
LOUIS A. BUTERA,=c�
to J'j CE -5735 fV��G
4�04� �OFESS10NPao��
SINGLE FAMILY ON-SITE WORKSHEET
ERES PROJECT NUMBER: 95-035
CALCULATED BY: LB
LEGAL DESCRIPTION: TIMBERLUX#3 LOT 6 BLKG
NUMBER OF BEDROOMS: 4
WATER USE PER BEDROOM: 150
GALLONS
PERCOLATION RATE: <1
MINUTES PER INCH
DEPTH TO GROUNDWATER: 6
FEET
DEPTH TO IMPERMEABLE LAYER: 8
FEET
USABLE SOIL STRATA
ANTICIPATED DEPTH OF COVER: 2
FEET
TOTAL USABLE DEPTH:
2
MOUND OR BED SYSTEM
USABLE SOIL STRATA DEPTH:
0
WASTEWATER APPLICATION RATE:
0.7
GAUSQ.FT
ABSORPTION AREA REQUIREMENT:
857
SQ.FT
MINIMUM BED LENGTH
12 FEET WIDE BED
71
FEET
15 FEET WIDE BED
57
FEET
TRENCH SYSTEM
WASTEWATER APPLICATION RATE:
N/S
GAL/SQ.FT
ABSORPTION AREA REQUIREMENT:
#VALUEI
SQ.FT
SHALLOW TRENCH OPTIONS
DEEP TRENCH OPTIONS
5 FEET WIDE TRENCH
3 FEET WIDE TRENCH
EFFECTIVE REQUIRED TRENCH
EFFECTIVE REQUIRED TRENCH
DEPTH (FT) LENGTH (FT)
DEPTH (FT)
LENGTH (FT)
I NA
4
NA
2 NA
4.5
NA
2.5 NA
5
NA
3 NA
5.5
NA
3.5 NA
6
NA
4 NA
7
NA
8
NA
9
NA
DESIGN SPECIFICS
FIELD SYSTEM: B (B=BED, S=SHALLOW TRENCH & D=DEEP TRENCH)
GRAVEL DEPTH: 1 FEET
TRENCH OR BED WIDTH: 15 FEET
LENGTH: 57 FEET
TOTAL
EXCAVATION
DEPTH: 4` FEET
. 2' FILTER SAND UNDER SEWER ROCK
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
..W -I� I
MUNICIPALITY OF ANCHORAGE
®. DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION )SEP 2 8'1,984
ENVIRONMENTAL ENGINEERING DIVISION -
825 LStreet- Anchorage, Alaska 99501 Telephone 264-4720 ((��
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION Rggg(('' TE ! V LE D
NAME
PHONE
3v95703
VrNEW
❑UPGRADE
MAILING ADDRESS /
LEGAL DESCRIPTION
LOCATION /-1a'1 r{/r.
NO. OF BEDROOMS 3
-
U Y
DISTANCETO:
Well
/10 well
Absorption area
Zy
Dwelling
/lob' rYI
PERMIT NO.
/„ '/fT7
7 [..n
_
WZQ -
~
Manufacturer �n c%ora'I
Material S 1
No. of compartments
N
Liq. capacity in gallons
I C'00
IF HOMEMADE:
Inside length
Width
Liquid depth
J C7z
DISTANCE TO:
Well
Dwelling
PERMIT NO.
= Z F
Manufacturer -
Material
Liquid capacity in gallons
LU
DISTANCE TO:
Well
'lot- '1
Foundation
"p+- .h
Nearest lot line
Y
PERMIT NO.
Lt ••n(Poe
J LL Z
FZW
No. of lines S�
Lang h of each li a
7- 7- 3 30
Total length of Ii es
/!`�
Trench width
L/6 inches
Distance between lines
os
I.-
p
Top of tile to finish grade
t. J
Material beneath tile
( inches
Total effective absor doR�area
��f
w
C7
Length
Width
Depth
PERMIT NO.
Q F
as
W
Type of crib
Crib diameter
Crib depth
Total effective absorption area
y
DISTANCE TO:
Well -
Building foundation
Nearest lot line
J
Class
Depth
Driller
Distance to lot line
PERMIT NO. -
w
�
-
DISTANCE TO:
Building foundation
Sewer line
Septic tank _
Absorption area(s)
OTHER
PIPE MATERIALS
PV e
SOIL TEST RATING
/`/O CT
INSTALLER
OWn el
REMARKS
N
6 5�
3 6 6
3
GD= y 'W a r B, t 7Ae /••/
wa-k— i viten+ •7e Irene 4, . /2a 'Ari ne
� 6<d 6 D� '. MOA- ST S yoz
iR ted. /
/' / Wat //7ovnckJ Cvee i ve i t
cou( r- Over S PA_ -
JT
rt
n
PROVED - DATE LEGAL%
Q ,+)
(Rev. 3/78)
' 6*'JL. k l f-- A F°IA - I -VY CJF E=eq`.1 b-1 7i A9
.
DEPARTMENT OF,HEALTH AND ENVIRONMENTAL PROTECTION
i 825 L STREET, ANCHORAGE, AK 99501"
k n 264-4720 .
"FERM'T NOp .840929
'
&MATE'lED:: . 11/01/84
1PPLI AlUT: CHARLES' R CUSHMAN `
Ad1RESS: 7209 FOXRIDQE CT. #2
r ANCHORAGE, Ak 99504
CONTACT `PHONE: '349-57 03
,GAL,`DESCRIP: "SUBDIVISION: TIMBERLUX #3' LOT: 6.,
BLOCK:. G '`�
SECTION: 34 TOWNSHIP: 12N RANGE:.3W
T SIZE: 1.25A (SQ.FT. OR ACRES)
SOT JCjItATIOM: MANYTELL
G'
EDROOMS: 3
` st.eci below are the options available to, you in designing your
septic, "
,lity. 4 em Ch se the,option that best fits your site. `
- - - - - - -- _ - - - - - - - - - -
- - - -
H1CJ PIPE,BOTTOM"(FT.) 3.5
DEPTH (FT.)" 0.5
DEPTH iFT.)
EL�
ANYFL,WIDTH (FT.) 18<0
AVEL LENGTH IFT:). 37.0,)
'ry
RAVS -VOLUME.(CU.YDS24.740
�%;NI{
SALE fgALS) 1, (.)00.OIL
DATING (SO. F.T. /BR) 1.46
DEPTH TO PIPE BOTTOM <: 4.0 FT. MAY REQUIRE, A. LIFT STATION
TANK MUST.HAVE,'AT LEAST TWO COMPARTMENTS
tify that:
�
am fAM1liar with the requirements for on-site seaters' and'
wells :as #'y < f,.
forth by t -he Municipality of Anchorage (MOA) and the State'oi
Alas�ea„,-
wilI_.install the system in accordance with all MOA,codes'and
retl8t <'
'Yn.-compliance with the design criteria of this permit.
r
.,I' Will adhe"re to all MOA and State of Alaska • requirements,
for the se
`
r= 'distanc" from any existing well, wastewater disposal system, or. publ1c'
-sewerasystem on this or any ad;ja�ent or nearby lot.
4, �-.und�rstalzd,t.hat this permit is valid for a maximum of .3
-;
bedrooms
i any'.enlargement will require an additional permit.
$
A 'OVT STATION T8 INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
Ii FAV ELECTRICAL PERMIT AND INSPECTION MUST 'BE OBTAINEDa
(2) ASUi1
T'y', Via'
1i #. APPROVEB WITHOUT AN ELECTRICAL INSPECTION REPORT; AND
(3) ;THE
r.
1
i I("FL WORK MUST BE DONE BY A LICENSED ELECTRICIAN.
10NFI<
,
BATEa��
Vo
APPLICANT: CHARL' R-CUSHMAN
ISSU` BY DaTEr
�f_Y^'+`."
; V11
G ..< -- i - -• _•r�
>
Z
y
MUNICIPALITY OF ANCHORAGE
DepartmenSpf Health and Environment Protection
825 L Street, Anchorage, AK. 99501
264-4720
Permit u o 7,1# g # HANDWRITTEN PERMIT # # #
n '
WELL AND* ON-SITE SEWER PERMIT
Applicant: C{ H L�� i� l( 1i' /9A) Mailing Address:
Location: Phone/ -Number :
Q�f /20
Legal Description: (,��% i� CS, zeaXL Lot
Type of Soil Absorption System Is:
Trench: �Drainfield: _ --.Seepage Bed:
Size:
Holding Tank:
Maximum Number of Bedrooms: .3 Soil Rating(sq.ft/br)
The Required Size of the Soil Absorption System Is:
DEPTH LENGTH _:63 GRAVEL DEPTH ! WIDTH �• S
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
* * REQUIRED SEPTI C) TANK SIZE _ �GALLONS # #
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
# # # TWO(2) INSPECTIONS AREa•REQUIRED # # #
Backfilling of any system without final inspect 6n and approval by this departure.
will be subject to prosecution. 1.
Minimum distance between a well and any on-site sewage disposal system is 100 fe
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other -requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 $ # # #
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence is remodeled to include more that bedrooms.
Signed: &(LA.((Li1lM(Ar1 Issued by: ✓f l�
Applicant p o U
Date:
SWP/024(1/81)
OQ � _0
a
• SOILS LOG c`I
MUNICIPALITY OF ANCHORAGE Vo7- I
' DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION
TEST
825 L. Street, Anchorage, Alaska 99501 264-4720
/SPOILS LOG — PERCOLATION TEST
PERFORMED FOR: Kar-er1 �—• US4/Yr/—r1 DATEPERFORMED: y�`a
LEGAL DESCRIPTION: [.�-1 6 -A/,cx 6 Z-fAr /�.. jE `� I H- 1I
o�P� SLOTPE SITE PLAN
y� / u I7} peai-
2 /
.. 3L S,-1k�Gla 1
4
5 I� C1 W\
0
7
s_. 9
cw �o
1� "O/Cloy
11
/
12
13 /
14
15tis'04T.o
W
17
18
19
(.10,
S1`I'I`I S¢rtl
WAS GROUND WATER
ENCOUNTERED?
t,./ t
6
Depth to
Water
yr...�l
gDime CI{'°' layCb
IF YES, AT WHAT
2 'wi g�
--
1
DEPTH?
SUh1t C-IQy
g�l�k. AJ(
(„�
all mrKed
`}-
2
USA
MENNNNNNEE
MWEENNOW
■E■■.■■■■■
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
--
`}-
2
e
oo
rs'
{ Yr
S^D
3
IM
a
bo
^o
{HJ
{0
2�
• ZY
S
w
{Tp
to
v
20
PERFLATION RATE
TES` -RUN BETWEEN
PERFORMED BY: �c7 9F sTgYo2% CERTIFIED BY:
0 72-008 (6/79)
-7y
ID (minutes/in i
FT ANT FT a{ 1 13
DATE:
0
KEN'S COMPANY
WATER WELL DRILLING
PUMP SALES & SERVICE
(907) 243-2282 30 YEARS ALASKA DRILLING 3163 LINDEN DRIVE
KEN JOHNSON ANCHORAGE, ALASKA 99502
SERT!. 25, 1984
CHARLES R. CHUSHMAN
7209 Foxridge Circle # 2
Anchorage, ;Alaska 99502 ( 349-5703 )
RE LOT 6 Blk 6 Timberlux �Iubd.
WATER WELL LOG
0 ft to 3 ft Course grav & and organics
3 ft
to
18
ft
Course grav & gray silt
18
ft
to
31
ft
Med. gray & dark gray silt
31
ft
to
35
ft
Same but weeps some H2 0
35
ft
t038
ft
Course grav and graysilt
38
ft
to
45
ft
Fin grav & brn silt
45
ft
to
59
ft
Same but weeps H2O
59
ft
to
72
ft
Course grav & gray silt dry ( tight )
72
ft
to
82
ft
Same.. tight formation but weeps
82
ft
to
94
ft.
Med. grav & gray slt ( dry )
94
ft
to
115
ft
ourse grav & brn silt with cobbles.
115
ft
to 121 ft
%ater bearing sand & grave
121 ft glean med. gravel & sand water bearing
Static water level 76 ft. ( toc )
Test bailed 12 hours at 6.6 GPM with 15' DD.
Good recovery
Bottom Stable
Total casing 121' -("
*UK-Cr�'Ty o < c o ce (^,' LD� ��
&FT. OF
EMUZONNIENTAL r,i�.� i:iION
DECO 5 1984 \tv a
RECEIVED
0 0
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information Application Date
(a) Legal Description (include lot, block, subdivision, section, township, range)
Iof(o d/& -,t 7-2,w BE4/ai/, 7/.Z At Ser'_ 3�
Location (address or directions)
(b) Applicants Name,_Telephone - Hom Susi e s�
Applicants AddressZQL
(c) Applicant is (check one) Lending Institution Owner/builder ;
Buyer 1__1 ; Other [� (explain);
(d) Lending Institution rpk�-.T ���!1
�-ems{aL y3Aa,)k Telephone --7:?74/- CES'(OS
Address'lZ
(e) Real Estate Co. 5 Agent
Address
-Telephone
(f) Mail the HAA to the following address: (� � r
0
4L -4s MA-v�gELL- 4V
Ah0l C, "Ct.Q A& q45-) 6
2. Type of Residence
Single -Family r77 Multi -Family
Number of Bedrooms .3
3. Water Supply
Individual Well � Community
Other (describe)
Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal
Onsite LX I Public E:�j Community [=I Holding Tank =
Note: If community well system, must have
written
confirmation from the
State
Department of Environmental Conservation
V
attesting
to the legality and
status.
[Page 1 of 2]
Engineering Firm Providing Inspections, Tests, File Search, Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, T
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula�-
tions in effect on the date of this inspection.
Name of
Date _?//7*1:
O
f. DHEP Approval
Approved for bedrooms By
Approved Disapproved
of
J -'F /'-T
CAUTION
Telephone 'ZI 10AIZ)
Conditional _
P:C.£.L.T P %o rN L,
I dui '
er
4,3
C. Reid, Jr. e•�:,�
. 2251-E • c '' '
r
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESE._-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DHEP SEAL)
RR4/ej/D18
[Page 2 of 2] 7-19-84
*MUNICIPALITY OF ANCHORAGE (MOA
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984 I"l5
Legal Description .c rI mra z
A. WELL DATA
Well Classification 1121611 e If A, B, or C, D.E.C. Approved(Y/N) N/�
Well Log Present) Date Ccnpleted ?IZ3-15-y Yield(
Total Depth /,2! Cased to /-,?/ ' Depth of GroutingNc�cxzusi/l��
Static Water Level 76Pump Set At Nof ax /off
Casing Height Above Ground Sanitary Seal on Casing Y )
Electrical Wiring in Conduit ) ` Z Depression Around Wellhead (Y
Separation Distances from Well:
To Septic/Holding Tank on Lot /03 On Adjoining Lots >!oo
To Nearest Edge of Absorption Field on Lot_22a On Adjoining Lots >ioo"
To Nearest Public Sewer Line To Nearest Public Sewer
Cleancut/Manhole AIIA To Nearest Sewer Service Line on Lot N111
Water Sample Collected By Lpol ; Date °212%S
Water Sample Test Results
B. SEPTIC/HOLDING TANK DATA
Date Installed � /S' C/ Size loco No. of Ccmpartments Z
Standpipes )(9) Air -tight Caps CYN) Foundation Cleanout Oy)
Depression over Tank (YA Date Last Pumped A 4
77
Pumping/Maintenance Contract on File (YIN) +q,A- ; for ku J.k
Holding Tank High -Water Alarm (Y/N) k)(/1- Temporary Holding Tank Permit (YM) 0-A
Separation Distances from Septic/Holding Tank:
To Water -Supply Wall /01 To Building Foundation fh:3
To Property Line To Disposal Field �2,2 r
To Water Main/Service Lire �� To Stream, Pond, Lake, or Major Drainage
Course > /c o' t
Receipt #
Date Paid: g�
Amount:
[Page 1 of 21
2-15-84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata /�,Dfia•' Type of System Design Sc!)
Date Installed WO /5-,( Length of Field
Width of Field t f� Depth of Field
Gravel Bed Thickness 0,5-
Square
,5Square Feet of Absorption Area Standpipes Present S J )
SD
Depression over Field (Y} Date of Last Adequacy Test
Results of Last Adequacy 'Lest 4
Separation Distance Fran Absorption Field:
To Water -Supply Wall /33 i CO To Property Line 514
To Building Foundation si /0, To Existing or Abandoned System cn
Lot wId. ; On Adjoining Lots T 30/ 0
To Water Main/Service Line 'V/4 To Cutbank(if present) 'WA
To Stream/Pond/Lake/or Major Drainage Course > IOU ,
To Driveway, Parking Area, or Vehicle Storage Area P7 /CO
Comnents r ,>. ,,,,,o Z,___ �1/.K: ^Y. ., Abll L$
D. LIFT STATION
Date Installed IV (A- Dimensions
Size in Gallons "v(/- Manhole/Access (Y/Iii'
"Pump On" Level at lid- "Pump Off" Level at u -)[A
High Water Alarm Level at —;7/t Vent .(YM) 1,0 /14
Tested for N(A, Pumping Cycles during Adequacy Test. Meets MOA
Electrical Ccdes(Y/N) A,)f,4-
Ccwents
** Check Permitted Bedroan Rating Against HAA Request **
I certify that I have checked, verified, or confcrmd to all MOA HAA r res in effect
on the date of this inspection.
Signed ��� Date
Y/`1�S ®r2z0xl� .°,°1
Company /-/�.� MOA No. *!A
OM.flB ua 6iqq
�.���'lk!.t�f.-BL�R_l�.• �i4 �•+.aa epo "6iq
RB1/d5/s
PROFESSI�����
(Page 2 of 21 Gem e"`'
{�, 2-15-84
Sent By: Alaska Water & Wastewater Consu; 907 338 3246; Dec -15-99 9:33; Page 2/2
ALASKA WATER F& WASTEWATER
CONSULTANTS. INC. r. ..v 11111�1.m 11 sr
December 13, 1999
Anchorage Tank & Welding, Inc.
2700 Porcupine Drive
Anchorage, Alaska 99501
Attn: Lowell MacNutt
Subject: Timberlux, Lot 6, Bk G. Chuck and Karen Cushman Property
Dear Lowell:
On 11/22/99 1 prepared a letter which addressed the recirculating trickling filter (RTF) on the
subject property. It was noted at that time that the liquid level in the bed type drainfield was
about 10 inches deep and that a plumbing leak was evident. Since that time the plumbing leak
was repaired, and the homeowners began to exercise a more 'normal" frequency of washing
clothes. On 12/14/99 I checked the liquid level in the bed an found it to be around 1.75 inches
deep (only 250 square feet of surface are in the bed). This corresponds to only about 90 gallons
of effluent in the pore space of the drainrock. Given the hard usage that is placed on this system,
the operating level is reasonable. In short, this system now appears to be operating normally.
If you have any
v. c. A+ Home Semites, Inc.
MOA, DHHS
please contact me at 337-6179.
M. S.
6901 Debarr Road, Suite 2-B * Anchorage, Alaska 99504
Ph: (907) 337-6179 * Fax: (907) 33R-3246 * awws@alaska.net