HomeMy WebLinkAboutKENO HILLS #1 BLK 4 LT 6Keno Hills #1 Block 4 Lot 6 #020-171-15 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: ________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Municipality of Anchorage Page / of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: S iY/ qL 60 b �LPiD Number: D,9D -;71— 1---) Name: Wastewater System: New ❑ Upgrade Address: ABSORPTION FIELD Phone: No. of Bedrooms: Deep Trench ❑ Shallow Trench ❑ eetl ❑ Mound 0 Other LEGAL DESCRIPTION Soil Rating: Total Depth fromdrigi net grade: /.z GPD/ (-/ tAt. K Lot: Block: Subdivision: Depth Depth to pipe bottom fmm original grade: Gravel depth beneath pipe 1.1 P (may � — 'T o I i_L- S l Ft. 6- Ft. Township: Range: Section: Fill added above original grade: Gravel length: `^ ` . _ Ft. ;L Ft. WELL f2/New ❑ Upgrade Gravel width: Number of lines: 0stance between lures: I Ft. j Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: i� 1 ✓A- r iE 9,t nn -v Ft :3 Ft. !'7 G V 806 Ft. Driller: Date Drilled: Static water Lave" lq Installer: II�Q keI Date instgllfd: �y �/�f �1L /ALPit-4 5.17. q(f, FL /G, Yield: _ Pump Set at: 'ap Sce Casing Height Above Ground: TANK .� GPM r t N Ft. r F Ft. SEPARATION DISTANCES t (Septic ❑ Holding ❑ s.T.E.P. To Saptlo Absorption Lift Holding Publlc/PrIvaie Manufacturer: Cap city in gallons: From Tank Field Station Tank Sewer tinea <591 0-- /,12-;j0 weir i l;ZU ! 3I. >o'l Material: S ��e Number of Comp menta: Surface +�Xl= io2o` `= LIFT STATION Lot j- ?() f •[- Size in gallons: Manufacturer: Line Foundation q I "Pump on" level at: "Pump off" level at: High water alarm at: Curtain NON& 11.4", Pump Make & Model Electrical Inspections performed by: Drain e. Remarks: BENCH MARK Location and Descriptions. Assumed Elevation: • r' /ilrl-'- �,tIG)NfiER'SpSEAL ?�yxi Inspections performed by: Dates: 1st I. +' r. 2nd 12r �L s Department of Health d Hu Se vices appr v Reviewed and approved by: ate: - S r 724)13 IRep. 9/911 MOA 25 V History and reasoning for approving the Inspection Report for permit SW960062 History: • It appears to have never been approved because of an outstanding review comment regarding the drainfield possibly being less than 6 feet above the bottom of the testhole. • In 2013 a COSA was approved without addressing the unapproved 1996 Inspection Report. The COSA indicated the total depth of the drainfield was not too deep for the test hole. • Today, 12/3/15, COSA OSC151634 indicates the total depth of the drainfield is not too deep for the test hole. • The well log found in On -site's file for the property shows the same soils found in the soils log extending to a depth of 38 feet below grade. • In light of all these facts, On-site decided to approve the Inspection Report. ��y�s 0 25 50 75 7*,o#00- I 0 SCALE. 1" = 50 F �,.•' {x ; 49th No. CE -2225 I O ti Q a Q U 2 a y REPLACEMENT TR PRIMARY Millm � I 41, Z O ebb O o / we fes` mi I.... I .1 P. I 8£ H MgRK;•::• j TANK ACT I BENCH MAg,�K•'f 0 DATION" ASSUMED £LEVAFy DO TDBBEN SPURKLAND P.E. LOT 6, BLOCK 4 KENO HILLS #1 SEPTIC SYSTEM AS LT 203 W 75TH. AVENUE ANCH. AK. 99501 KEN BECKLEY DATE: JUNE 29, '1996 1 - 17300 ASHLAND DRIVE _ SHEET: 2/3 GRID: 3438 12 42 CLEAN OUT AND MONITOR --- Standard Trench 2' Wide 42' L ong 14' Deep 6' Sewer rock 4' Cover PRIMARY TRENCH NO SCALE /— Cleanouts 9& RLfa REPLACEMENT TRENCH V c f 5 8 f0 ■► w a -O-O- CLEANOUT 1250 got Septic tank Monitor, f NwE-'SS Mirof'/ 140 IF .•.•.•.•.•.•.•r,•,•,m o,•,a•g,.g ,go '�, , INVELE. 91.40 85. Ji - 6 Ft OF Septic Rock NO BEDROCK NO GROl TER 1250 gal. septic tonk GREER NU SCALE TESTHOLE , DEEPEND TO 20 FT. 6 BENCH MARK •• rouNDA ASSUMED ELEV. loo.00 FT 17JO0 ASHLAND DRIVE�, LOCATION OF WELL STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT WATER WELL RECORD CONTRACTOR INFORMATION: REMARK; : PLEASE MAIL WHITE COPY OF LOG TO: DNR/DIVISION OF MINING & WATER MGMT 3601 C St, Suite 800 Anchorage, Ak 99503-5935 Ph(907)762-2538,rax(907)562-1384 ]DRouOH ]LOCK SECTION OTRS SECTION TOWNSHIP RANGE MERIDIAN ' LLOT e. I ON 1 ❑E Y/ QS ❑W LOCATION/SKETCH: WELL OWNER: DEPTHS MEASURED FROM:❑casing top ❑ground surface WELL DEPTH: 5DATE OF COMPLETION 52,ADepth of hole: � `�� It Depth of casing: –4=ft –5� BOREHOLE DATA: Depth Material Type and Color From To r DEPTH TO STATIC WATER LEVEL: /9 it below map of casing ❑ ground surface '! / Date: S ! 77 1 9_ ^ METHOD OF DRILLING: $ air rotary ❑ cable tool ❑ other USE OF WELL: /9 domestic Q irrigation ❑ monitor � c�Y o400Q ❑ public supply Q other CASING STICKUP: .:2 ft. Diam: In. to _ ft p $ Casing type: in, t0 ft WELL INTAKE OPENING TYPE: ❑ open end ❑ Screened C7 perforated /j' open hole Depths of openings: to it SCREEN TYPE: Diam; In. Slot/Mesh Size: Length: ft GRAVEL PACK TYPE: Volume'used: Depth to top: GROUT TYPE: Volume: Depth: from - it to ft t' DEVELOPMENT l ETPD: Q`(� Pncv%otal t ut pSe r PUMPING LEVEL AND YIELD: �Z �it after ;2—� hrs � Ngatth & --- pumping gpm pt PUMP INTAKE DEPTH: ft Horsepower; WELL DISINFECTED UPON COMPLETION? S YES ❑ NO CONTRACTOR INFORMATION: REMARK; : PLEASE MAIL WHITE COPY OF LOG TO: DNR/DIVISION OF MINING & WATER MGMT 3601 C St, Suite 800 Anchorage, Ak 99503-5935 Ph(907)762-2538,rax(907)562-1384 � 0 �, / - $,fl.� i2c---u,EG� .E"k&- 3S«uo- \ )t \\ /\ Z; >1,4 k + 3� e * ƒ m � A #0,4 coPl PAGE 1 OF 1 + , MUNICIPALITY OF ANCHORAGE - 1 C`m ' DEPARTMENT OF HEALTH AND HUMAN SERVICES CLU P.O. BOX 196650, 825 "L" STREET, ROOM 502-A ANCHORAGE, ALASKA 99519-6650 hc40, cuw �`p � ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960062 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:SCHMIDT FAMILY TRUST OWNER ADDRESS:17300 ASHLAND DR ANCHORAGE, AK. 99516 PARCEL ID:02017115 LEGAL DESCRIPTION: KENO HILLS #1BLK 4 LT 6 LOT SIZE: 133729 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: DATE ISSUED: 4/29/96 EXPIRATION DATE: 4/29/97 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED ISSUED BY 5 -da 96 Ew CdrvSYdU /�� c-ro "I,"O _(Z7,7 A/ jg WAS G CNa� DATE: Vl36/1?6 DATE •�J G6/ T.SPURKLAND P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 6, BLOCK 4, KENO HILLS Ken Beckley No Ground Water or Impervious Layer to 16 ft. Use Standard Trench Soil Rating. < 1 min/in = See Sieve Analysis Use 1.2 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 15011.2 =125 sq.ft.. Total area required: 4 x 125 = 500 sq. ft. Finish Floor Elevation Basement 1062 Septic Tank Inlet 1060 Septic Tank Bottom 1056 Ground Elevation at Absorption Field 1064 Testhole Total Depth 16 Bottom trench elevation 1054 Rock depth 6 ft. Top of Rock Elev. 1060 Length of trench 500 / 12 = 41.67 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 42 FT TOTAL WIDTH 2 FT TOTAL DEPTH 10 FT ROCK DEPTH 6 F COVER 4FT SEPTIC TANK 1250 GAL NOTE: PUMPER ACCESS The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are natural surface / sub surface drainage courses on this lot. Proposed septic system is more than 100 feet distant from any surface water The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. �rs � 49004 � \v �– \ LOT 6 \v \ �x ✓9Rp��PG 0 �yo �` JO �` OQ LQT 3 _ _ 387.14 ' LOT 7 LOT 2 \ r9 50 49th �. �. T,• DEN •SPURKLAND .................... ! \\ �♦r�j'., NoEE-2225— �� F'P^ •'••- •• •'O Fay - 0 N LOT 2 1 LOT 3 I I I �0 LL, ti q I LOT 4 I I 0 56 100 150 SCALE 1" k 10Q FT, we]1 250 — 300 IIUbULN J UKKLANU F.L. I I LOT 6, BLOCK 4 KENO HILLS #1 I I SEPTIC SYSTEM DESIGN I 203 W 15TH. AVENUE - DATE: APRIL 5, 1996 ANCH. AK. 99501 KEN BECKLEY (OA7) 970_:ola 17300 ASNLAND DRIVE SHEET: 1/3 GRID: 3438 r 25 0 25 50 75 100 125 1,511 SCALE- I' - 50 FL •••�.aaq�11, 49th .1K ... t::100' n TD BEN SPURKLAND No, CE -2225 ��?;J 0 W h e a e 1301 FEET U ti ..�._ Q REPLACEMENT TREND PRIMARY TRf 30I'_ j TANK ACCESS I I TOBBEN SPURKLAND P.E.SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE LOT 6, BLOCK 4 KENO HILLS #I ANCH. AK. 99501 KEN BECKLEY DATE: APRIL 5, 1996 -- 17300 ASHLAND DRIVE SHEET: 2/3 GRID: 3438 0 w 3 0 Qj Qj 42 — s — — 10 1�-� to a► =� I a -0-0-O O CLEAN OUT AND MONTOR CLEANOUT 1250 gal Septic tank Standard Trench - 2' Vale 42' Long 10' Deep 6' Sewer rock 4' Cover NO SCALE Mira Fi 140 6 Ft of Septic Rock Cleanouts 4' Cover NR SCALE 0 Monitor 1054 NO BEDROCK NO GROUNDWATER 49th SPURKLAND rr_o�os Exist, Ground 4' Min Cover over Tank 1056 1,150 gal, septic tank BENCH MARK GARAGE FLOOR ASSUMED ELEV. lo72 TOBEEN SPURKLAND P.E. LOT 6 BLOCK 4 KENO HILLS SEPTIC SYSTEM DESI6N Anchorage Ak 9DATE: Ave Anchorage KEN RRCKLEY APRIL 5, 1996 Anc9501 ,,,, ,,.., 17300 ASHLAND DRIVE SHEET: .3/3 GRID: 34.?A • s, OW PERFORMED LEGAL Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 625 "U' Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST SLOPE (ENGINEERS SEAL) ?� � aU n •e I �'. `9 DATE PERFORMED: Section: 9 d d D U 10 11 ® a 12 r 6 � 13 r J b 14- 15- 4 15 16 17 T3 } >0 �i d1Nt _ A,7- ,-1 WAS GROUND WATER �) ENCOUNTERED? V S IF YES, AT WHAT L DEPTH? L p E Depth to Water Alter r Monitoring? Dale: •b Reading Date Gross Net Depth to - Net Time Time Water Drop 19 20--e_e— 017 r• mr71v� ' xe ` y7, �7� PERCOLATION RATE < (minutes/inch) PERC HOLE DIAMETER FfTEST RUNBETWEENFT AND FT COMMENTS S -Ca PERFORMED BY: _ J , ->- I Y _ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) -r" G !7MMpViSa 30 Lu3�HId 9 6 O c aR. 0.105 d 30 Y'Milud I.M. `b' •- � b M " n U � u y � xp� 3_ X X X � d, y � xp� 3_ el � n, u� W a SG 1-H 6 c d, xp� 3_ el � n, a J • Municipality of Anchor ° On -Site Water and wastewater Progra NOV 1 7 2015 r (907)'W-1904 s A e r r CERTIFICATE OF ON-SITE SYSTEMS A VAL_ Parcel I.D. 020-171-15 Expiration Date: 3 i 1 1. GENERAL INFORMATION Complete legal description KENO HILLS #1 BLOCK 4, LOT 6 Location (site address) 17300 ASHLAND DRIVE, ANCHORAGE, AK 99516 Current Property owner(s) ROBERT & KAREN WENTZ '' Day phone Mailing address 17300 ASHLAND DRIVE, ANCHORAGE AK 99516 Real Estate Agent Day phone ' 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or. Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank Community Class Well ❑ Community El Public Water, System ❑ Public Sewer El WaiverNariance request for: Distance: Received by: COSA to be released to the engineer, unless of - i quested by the. engineer. COSA Fee Waiver Fee $ Date of Payment t It g f L 5 Date of Payment Receipt Number 6-7d}5 EJ Receipt Number COSA# o5Ct s I (0314 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal.affixed hereto and as of the validation date shown below,'I verify that my investigation, . based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, Shows that the on-site water supply and/or wastewater disposal system is (are) safe,, functional and adequate for the number of bedrooms and type of structure indicated herein. t (further verify that based on the information obtained fromithe Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. - Phone 868-3791 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 11-17-2015 Engineer's Comments: This investigationwascompleted in compliance with ADEC and MOA regulations. The assessment of the: condition of the well and septic applies only to the conditions: as of the day -tested. The: flow andabsorptionrates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may. fluctuate during the year and the water usage of the family being served by the. system. The operational life of all well and septic systems are subject to these various and: dynamic characteristicsandare outside the control of the evaluator of the well and septic system. Therefore; ArcTerra can not giveany estimate of how long a system: will function satisfactory for current or future. occupants or. can ArcTerra guarantee that no unseen OF AL\ encroachments, deficiencies or discrepancies exist. / 4 �� , Ar '0'* 4,9 Tx 1 6. DSD SIGNATURE System #1 Approved for bedrooms.` ; 6 System #2 Approved for bedrooms. ,,nom° <� /'7 is °i °�oFesstoNA`' � Disapproved. Conditional approval for bedrooms, with the following stipulations: Y1 OF.,,1 WATER AND �� PP�CIGRAM�o^ By: 1 Original Certificate Date: Z�% C The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 byan independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work: 7. ATTACHMENTS:: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 1a-10-12.dw _ - If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this SYS—tem _ Certificate of On -Site Systems Approval Checklist Legal Description: KENO HILLS#1 BLOCK 4, LOT Parcel ID: 020.171.15 A. WELL DATA Well type PRVr If A, B, or C provide PWSID # _ Date completed 5117/1996 Sanitary seal (YIN) Y Total depth 226 ft. Cased to 63 ft. FROM WELL LOG Date of test 5/1711996 Static water level 19 ft. Well production 5 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 0.974 mg/L Arsenic: ND ug/L Date of sample: 11.6.2015 B. SEPTICIHOLDING TANK DATA Tank Type/Material SEPTIC I STEEL Tank size 1250 gal Number of Compartments 2 Foundation cleanout (YIN) Y Depression over tank (YIN) N Date of pumping 512212015 Pumper A+ C. ABSORPTION FIELD DATA Date installed 5/2211996 Soil rating (g.p.d./f:2 or a/bdrm)1.2 Length 42 ft. Width 2 ft. Total depth 12.5 ft. (Measured 11-6-15) Eff. absorption area 504 ftZ Well Log (YIN) Y Wires properly protected (YIN) Y Casing height (above ground) 18+ in. AT INSPECTION 11.6.2015 ft. Collected by: ARCTERRA Date installed 5/2111996 Cleanouts (YIN) High water alarm (YIN) N System type DEEP TRENCH Gravel below pipe 6 ft. Monitoring tube _Y Depression over field N Date of adequacy test 11-6.2015 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 in. Elapsed Time:1 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed "Pump on" level at _ in. Datum Size in gallons Manhole/Access (Y/N) "Pump off" level at —in. High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES WELL ON LOTTO: Septic tank/lift station on lot 1001+ Absorption field on lot 100'+ Public sewer main 75'+ Sewer/septic service line 25'+ Animal containment areas 50'+ SEPTIC/HOLDING TANK ON LOT TO: On adjacent lots 1004 On adjacent lots 1004 Public sewer manhole/cleanout 1001+ Holding tank 100'+ Manure/animal excrete storage areas 1004 Building foundation 51+ Property line 5'+ Absorption field 5'+ Water main 101+ Water service line 10'+ Surface water 100'+ Weiss on adjacent lots 1001+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 101+ Water Service line 10'+ Surface water 1001+ Driveway, parking/vehicle storage 104 Curtain drain 50'+ (NONE KNOWN) Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COS4A guidelines in effect on this date. Engineer's Printed Name KENNETH M. DUFFUS Date 11-17.2015 COSA canary sheet 2-645:ddc —d � \ ��OF AI'\� / // e� �r Apr � �%' a�g�tORAt' .s Parcel I.D. 020-171-15 �c e� Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description Location (site address) Expiration Date: S –7 ( 3 KENO HILLS #1 BLOCK 4 LOT 6 17300 ASHLAND DR., ANCHORAGE, AK 99516 Current Property owner(s) KEN BECKLEY Mailing address Real Estate Agent 2. TYPE OF DWELLING: Fxj Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 345-4552 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: NONE Distance: Received by: _ _� Date: ' 9 COSA to be released to t e engineer, unless otherwise requested by the engineer. - COSA Fee $ `T ID — Date of Payments ! r'� _ Receipt Number COSA#— OS Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below. I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application; shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm SPURKLAND ENGINEERING Address 203 W. 25TH AVE.,STE.202A, ANCHORAGE, AK 99501 Engineer's Printed Name LARS SPURKLAND 6. DSD SIGNATURE System #1 Approved for _ bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for Phone 279-3916 Date 5/1/2013 N, r� A f { 7, a itoo d bedrooms, with the following s0��RStSIU�` By: G Original Certificate Date: —7-13 The M nicip� ity o orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet ° n .. Nitrate Advisory. Arsenic Advisory'' Other If more than 1 septic system is on the lot: COSA Checklist # 1 of 1 Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: KENO HILLS #1 BLOCK 4 LOT 6 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID #- Date completed 5/17196 Sanitary seal (YIN) Y Total depth 228 ft. Cased to 63 ft FROM WELL LOG Date of test 5/17196 Static water level 19 Well production 5 WATER SAMPLE RESULTS ft. g. p. m. Coliform NEG colonies/100 mL Nitrate 0'924 mg/L Arsenic NO ug/L Date of sample: 4122/13 B. SEPTICIHOLDING TANK DATA Tank Type/Material GREER/ STEEL Parcel ID: 020-171-15 Well Log (YIN) Y Wires properly protected (YIN) Y Casing height (above ground) >18 in. AT INSPECTION 6/12/12 17 4.1 ft. 9 - p.m - Collected by: ANSON MOXNESS Tank size 1250 gal. Number of Compartments 2 Foundation cleanout (YIN) Y Depression over tank (YIN) N Date of pumping APRIL 22, 13 Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA Date installed 5/21/1996 Cleanouts (YIN) Y High water alarm (Y/N) N Date installed 5/22196 Soil rating (g.p.d./fiz or ftz/bdrm) 1'2 System type DEEP TRENCI Length 42 ft. Width 2 ft. Gravel below pipe 6 ft. Total depth 13'2 ft. Eff. absorption area 504 fe Monitoring tube Y Depression over field N Date of adequacy test 6/12/12 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test O in. Water added 600 gal. New depth 1 in. Elapsed Time: 10 min. Final fluid depth 0 in. Absorption rate >= 600 g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NO If yes, give date - D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons - in. "Pump off' level at E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot >100' Public sewer main NA Cycles tested >100' Sewer /septic service line 25 Animal containment areas >50' Manhole/Access (Y/N) --- in. in. High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots >100, On adjacent lots >100, Public sewer manhole/cleanout NA Holding tank NA Manure/animal excrete storage areas >100, SEPTIC/HOLDING TANK ON LOT TO: Building foundation 91 Property line >5 Water main NA Water service line >10, Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10 Building foundation >10 Water Service line >10 Curtain drain >50'(N.O.) F. COMMENTS G. ENGINEER'S CERTIFICATION Surface water >100'(N.O.) Wells on adjacent lots >100, I certify that i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name LARS SPURKAND Date 10/16/12 COSA brown sheet 10-10-12.doc Absorption field >5 Surface water >100- (N.O.) Water main, NA Driveway, parking/vehicle storage >5 .� �E.®�•A4,gslil // A, 10 AHS SPU, KLAND:� art►��A�,;_5��� 3.:�;��-� — *da aNV IHSd - -- W zz Ie!y I � W 1 0! / I/ I/ I / I/ / I 5 � 0 5"E 377•,59 . I/ 30HOM8 "M -3N0 PLOT PLAN _ AS BUILT X SCALE 1" - 50' GRID 3438 Project No. 12-051/A1 Lang & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Registered Land Surveyors (907) 522-5478 Phone 9 Y (907) 522-4925 Fax ken0iangsurvey.com m OF A/ / JonafharMongsurvey.co•.......... qr� I hereby S. BLOCK 4h I have surveyed the following del (Pio p1-42)• !AT 5, BLOCK 4, KENO t. Al SUBDIVISION, ADDN ipt (Plc} 71-42) (,; •: Mohoroge Recording DIsMo}, Alaska. and that the Improwm•nts sl}uaiad thereon aro # : 49� ••. a within the property lines and do not encroach onto the =adjacent """""""'•'• f'•••••••••• no Ira rovements on the thereto, that P property lying ys. trans thereto sor on the surveyed Promises and that there aro no roadways, transmission lines or other visible :r:: • Q Al..... eacemants on said properly except as Indicated heroon. KENNETH G. t'ANCC 5202 Dated this the I Day of 'Su.,,c• , 2o11, . of Anchorage. Alaska y¢,r�1t11- �p It is the responsibility of the owner to determine the existence of any easements, , '�fESS1aHN.1P' covenants, or restrictions which do not appear on the recorded subdivision plat.