HomeMy WebLinkAboutUS SURVEY 3042 LT 88C T10N R2E SEC 19U
3042
T10N R2E ,Sec. 19
Lo1' 88C
#020-113- 55
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
parCel I.D. 075-132-40
t. GENERAL INFORMATION
Expiration Date: 7- ,/~ - /,~.
Complete legal description
Location (site address)
TION, R2E, SEC 19, LOT 88C (~/~" ,~'~"~J~YF:'/~/
116 JEWEL MINE ROAD *GIRWOOD~ AK 99587
Currant Property owner(s)
Mailing address
Lending agency
Mailing address
RICK & DEBRA COLEY
Day phone C/O AGENT
116 JEWEL MINE ROAD *GIRWOOD~ AK 99587
Day phone
Real Estate Agent
SAM DANIEL W/ GLACIER REALTY
Day Phone 783-1910
~,;~,Malingaddress 174 HIGHTOWER'S RD *GIRDWOOD ROAD 99587
Un/ess othen~sa ~quested, COSA will be held by DSD for pickup.
2. NUMBER OF 'BEDROoMs:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
· Individual On-site []
[] Individual Holding tank []
[] Community On-sita []
[] Public Sewer ·
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems
Approval are valid for 90 days f~om the date of issue for properties served by a pdvate or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a pedod of up to one year with valid water
samples.) Certificates ara valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4, STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Phone 337-6179
Address 5701 E. TUDOR ROAD, SUITE 101 '~ ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A, GARNESS, P.E.
Date
Engineer's Comments:
· In conducting this eva/uafion, GEG, LtD. attempted to provide a thoreughj
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results descdbed the pedormance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operafionat fife of all wails and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluater of the system. Satisfactory lest
results do not guarantee futura perfarmanoe of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system wi//continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for'
the sofa benefit of the owner listed above. Any reliance upon or use of this report by any
other person or parly is not authodzed, nor wifi it confer any legal right whatsoever.
5. DSD SIGNATURE
~/" Approved for
bedrooms.
Disapproved.
Conditional approval for __
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
,)~~ Original Certificate Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
{907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
LegalDescription: TION, R2E, SEC 19, LOT 88C
A. WELL DATA
Well type PRIVATE
Dote completed UNK
Total depth 84 ft.
IfA, B, orC provide PWSID8 N/A
Sanitary seal (Y/N) YES
Cased to 60+ ft.
~, C~/{ ~/~'y13arcel ID: 075-132-40
Well Log (Y/N)/V' ~
wires pmpedy pmte~ed ~/N) YES
Casing height (above ground) 12+ in.
FROM WELL LOG AT INSPECTION
Date of test NO WELL LO0 4/2/12
Static water level ~ ft. 73 ft.
Well production ~ g.p.m. 5.52 .g.p.m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mi. Nitrate __mg./L.
Arsenic: i® ug./L. Date of sample: 4/2/12
B. SEPTIC/HOLDING TANK DATA
Collected by: GEG, Ltd,
PUBLIC SEWER
Tank Type/Material Date installed
Tank size.__ gal. Number of Compartments __ ~
Foundation cleanout (Y/N)__ De~ High water alarm (Y/N)
Pumper
C. ABSORPTION FIELD DATA
Date installed Soil rating (g.p.d./ft2or ~/bdrm).__ System type
Length ft. Width ft, Grav~.
Total depth ft. Eft. absorption area ft2 Monitoring tube.~ / Depression over field. ~
Date of adequacy test R~ For_ bedrooms
Fluid depth in absorption fiel~ in. Water added_ gal. New depth in.
Elapsed T'~ Final fluid depth in. Absorption rata >= g.p.d.
~/y~nation treatment (past 12 mo.) (YIN & type) If yes, give date
D. LIFT sTATION
Date installed Size in gallons Manhole~
"Pump on" level at_ _in. "Pum~ High water alarm level at in.
Datum -- Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot N/A
Absorption field on lot N/A
75'+
Public sewer main
Sewer/septic service line
Animal containment areas.
On adjacent lots N/A
On adjacent lots N/A
Public sewer manhole/cleanout 100'+
25'+ Holding tank 75%
50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation Property line Absorption field
Water main Water service line Surface water ~
Wells on adjacent lots ~
SEPARATION DISTANCE FROM ABSORPT~OT I?:' .
Water service Iine~ .~ s~n'veway, parking/vehicle storage
~ Wells on adjacent lots
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Pd.nts¢ Name JEFFREY A. GARNESS
Date uc/,,/Iz
COSA Fee $ q q6
Date of Payment q/tl] tZ
Receipt Number 6 I ~--~)~'~'~
(Rev. tl/05)
Waiver Fee $
Date of Payment
Receipt Number
SGS Reft#
Client Name
Pro.iect Name/#
Client Sample ID
Matrix
1121020001
Gamess Engineeriag Group, Ltd
T10N R2E Secl9 L88C USS Survey
T1 ON R2E Sccl9 L88C USS Survey
Drinking Water
Printed Date/Time
Collected Date/Time
Received Date/Time
Technical Director
04/09/2012 17:51
04/02/2012 15:15
04/02/2012 16:15
Stephen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00
ug/L EP200.8 C (<10) 04/04/12 04/05/12 ACF
Waters Department
Total Nitrate/Nitrite-N 0.515 0.100 mg/L SM21 4500NO3-F B 1<10) 04/05/12 LCE
Microbiolo91; Laboratory
E. Col/
Total Coliform
Negative 1 100mL SM2I 9223B A 04/02/I2 DLC
Negative I 100mL SM21 9223B A 04/02/12 DLC
2 of 4
Aarow Pump & Well Service, LLC
P.O. Box 110496
Anchorage, AK 99511
Office: (907) 346-9355 · Fax (907) 333-8976
Eagle River: (907) 622-9335
No. 9329
CUSTOMER
-1 [-
JOB SITE
"QUANTITY DESCRIPTION PRICE AMOUNT
/
LABOR HOURS RATE AMOUNT TOTAL MATERIAl
/ / / /
WORK ORDERED BY DATE COMP. TOTALLABOR
ThankYou
SIGNATURE
(I Hereby Acknowledge the Satisfactory Completion of the Above Described Work and agree that if above work is not paid for in 90 days I agree to allow Aarow
Pump & Well Service, bEC. the right to remove unpaid for equipment and charge for labor already per[ormed & labor to remove unpaid for equipment.)
TERMS: ACCOUNTS PAYABLE AT 10TH OF MONTH FOLLOWING PURCHASE.
SERVICE CHARGE AT RATE OF 1.5% PER MONTH WILL BE CHARGED ON OVERDUE ACCOUNTS.
0
/
/
/
/
0
0
DATE:
TO:
FROM:
SUBJECT:
MEMORANDUM
91-010 (5~78)
. US~
Date ~
' ZONE
ROVED
(lo,~e as sllotDll
~ccl
be changerl,
~t ]ir~ ob~nt~
t