Loading...
HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 24BEagle River Valley Ranchettes Lot 24B #050-223-20 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 050-223-20 Expiration Date: 5IT/2117 Legal description EAGLE RIVER VALLEY RANCHETTES LOT 24B Site address 18732 Twenty Grand Rd Eagle River Current property owner(s) Melissa and David Romero X The On-site system(s) is/are approved for 3 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: By: �'� Original Certificate Date:_7J1?a "i This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory X Arsenic Advisory Other COSA Approval June 2022 �, t Oj' ;ice Development Services Department _ Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 050-223-20 Complete legal description EAGLE RIVER VALLEY RANCHETTES LOT 24B Location (site address) 18732 TWENTY GRAND ROAD, EAGLE RIVER, AK 99577 Current property owner(s) MELISSA & DAVID ROMERO Day phone 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ® Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 25 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Date of Payment COSA # QSC' P"; to 673 003 Waiver Fee $ Date of Payment Waiver # COSA Application.doc Septic Tank Advisory Certificate of On -Site Systems Approval # OSC231019 Subdivision: Eagle River Valley Ranchettes Block: , Lot: 24B The septic tank for this property is 25 years old. The average life for a steel septic tank is 20 years. Typical replacement costs range from $7,000 to $11,000. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. COSA Checklist.docx COSA Checklist Legal Description: EAGLE RIVER VALLEY RANCHETTES LOT 24B Parcel ID: 050-223-20 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA - PUBLIC &/OR CLASS “A” WATER Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank 48” Date of pumping 1/24/2023 Required maintenance completed, if AWWTS Comments: 25-YR S.T. – SEE MOA ADVISORY C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 10/1988 ALL standpipes present per record drawing Total measured depth from grade 6.9 ft (max) Measured depth to pipe invert from grade 3.4 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective 4.26’ - MOA IR: 4.5’ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 1/25/2023 Results Pass Fluid depth prior to test 43 in (INCLUDING MISSING ED) Water added 450 gal (SHOTS SHOW -3” MISSING ED) New fluid depth 55 in (INTO INVERT) Elapsed time 1440 min Final fluid depth 42 in Absorption rate 450 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 54 in Effective depth used 43 in Effective depth remaining 11 in Comments/Deficiencies: Elevation shots show 4.26’ of the 4.5’ MOA ED. System barely passes septic adequacy test. JRs fixed caps & switched diverter to 1998 trench which was dry & per shots had 3.26’ effective depth of the MOA 4.5’ ED. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS Separations per visual observations, available MOA on-site record documents and the attached AWWU documents. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 2/07/2023 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 2/7/2023 Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Na'"e:~'7-~.'~ ~ ~o Wastewater System: ~ New ~Upgrade Address: Phone: ~ ~3~ I NO. of Bedrooms: ~ ~ Deep Trench ~ShallowTrench ~ Bed ~ Mound B Other TotaID th fr~moriginalgrade- LEGAL DESCRIPTION SoilRati.g; /'~ GPD/Sq. Ft. ~ ' Subdivision: Deplh I~ pipe bottom from original grade: Gravel depth beneath pipe Township: IRa IS n:7 /'~ ' fit. Ft. ~*~ n~e~ ~ Fill added above original grade: Gravel length: Gravel width: ~ Number of lines: I Distance between ~in~: WELL: ~/ ~ New B Upgrade ~ ~ Ft. ~I ~ Ft. Classification [Private, A,B,C): Total Depth: ~d TO: Total absorption area: Pipe material: Y~ ~mp~at:~r=lle~ ~p~ Date Drill~d:~ Stab~W~ter L~vel: rnst~der:~ ~ate i Casing Height Above Ground: ~. .~. TANK SEPARATION DISTANCES ~Septic D Holding D S.T.E.P. TO Septic Absocption LiR HoJding ~ublic/Private Manufacturer: Capacity in gallons: From Tank Field Stalion Tank Sewer Lines Well ~¢ [ Surface Foundation ~ ' ~- / ~ "Pump on" revel at:~"Pump o~,1~ a~:II HiOh water alarm at: Curtain Pump M~lectrical Inspections performed by: Drain Remarks: ¢~// ~ ~ BENCH MARK Location and Description: , . I Assumed Elevation: ENGINEER'S SEAL Department of Health and Human Services approval Reviewed and approved by: ¢~.~ / ~. 72-013 (Rev 9/91) MOA 25 Permit No. $W970240 Page 2 of Municipality of Anchorocje DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 Te~phone: 343-474-4 On-Site Westewater Disposal System end/or Well Inspection Report Legal Description: Eagle River Valley Ranchettea Lot 24B PID No.: 05022320 2 TWENTY GRAND ST. S 89'59'15" E 133.00 OI~IVE ~THI ~ T~ENCH : ] o SEWER CL~NOUT EXISTING LEACHFIELD N 8~59'15" ~ SCALE 1"=30' 6/16/98 ELEVATIONS (NDT TD SCALE) A-C = 87' B-C = A-D = 126.4' B-D = 136' BLOCK LOT(S) ADDRESS / &7 '\? .N Ke.ybox As-Built Date Work Performed Condition of Kevbox/Comrrrent s PAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM {UPGRADE) PERMIT PERMIT NUMBER:SW970240 DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES OWNER NAME:PONTO STEPHEN OWNER ADDRESS:P O. BOX 240003 ANCHORAGE, AK 99524 DATE ISSUED: 8/05/97 EXPIRATION DATE: 8/05/98 PARCEL ID:05022320 LEGAL DESCRIPTION: '~L~?:iR!¥ER VAL~E~ RANQHE~TE$ LT 24,B '; LOT SIZE: 17955 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18A-AC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ~ DATE: DATE: Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax July 29, 1997 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Eagle River Valley Ranchettes Lot 4b Narrative & Permit Application Dear Mr. Cross: The proposed septic upgrade will have very limited impact on adjacent properties for the following reasons: 1. 3. 4. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. The surrounding lots are served by public water, allowing sufficient room for septic sites. Immediate neighboring septic systems are all +30' distance. Reserve space is adequate, due to absorption capacity. Drainage will not be affected and is not a major consideration in our design. MUNICIPALITY OF ANCHORAG~ ENVIRONMENJ"AL SERVICES DIVISION RECEIVED \1997197-042-N~..DOC Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax LEGAL: SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM Eagle River Valley Ranchettes Lot 24B 7f29/97 A. GENERAL 1. The well and septic plan are for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. Ali soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Consen~ation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaining open test hole excavations shall be filled. B. SEPTIC TANK 1. The existing septic tank shall be removed and replaced,~iy a tank with a minimum capacity of 1000 gallons and be of MOA approved design. C. TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 7 at any point. 4. The sewer line is to replace the existing sewer line that leads to the existing trench. The effluent line within the trench shall be laid level within 0.03'. 5. The trench gravel is to be covered with typar fabric material. 6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leachfield. 7. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leachfield must not be closer than I00' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH = 7' GRAVEL DEPTH = 4.5' under pipe, 2" over pipe TRENCH LENGTH = 42' TRENCH WIDTH = 3' SOIL RATING = 1.2 GPD/ft2 BEDROOM CAPACITY = 3 SEPTIC TANK = I000 -- Twenty-four (24) hours notice required for all inspections. \1997~97-042-spc.doc Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~1 7''~ LEGAL DESCRIPTION:~,~;2z~' ~ I 2 3- 4- 5 6 7 8 9 10- 11 13- 14- 15- 16- 17 18 19 2O COMMENTS DATE PERF~%~iORMED: ~ .~/~z'.~.~ ~e,~.~#.J'ownship, Range, Section: SLOPE fi WAS G.OUND WATER /V¢ ENCOUNTERED? SITE PLAN S IF YES, AT WHAT /~// DEPTH? PE Oeplh to Waler Alia' /a Moniloring? ¢~/~. Dale:. ?-3o-f 7 Reading Date Gross Net Depth to Net Time Time Water Drop I l 6:"15 5-,X~ ,, PERCOLATION RATE '~' ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT RERFORMED BY: *~'"',¢'¢"'~'"'~ I ~ CERTIFY THAT THIS TEST WAS RERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~- ~'~ --~ ~ 72-008 (Rev. 4/85) TWENTY GRAND ST.. 133.00 r c_~ HOUS~ ? ~ ~EP~CE SEPTIC +30' ~ ~1 / Tl~CH '- NO WELL / ~ ~ / WATER UNE Note: cro~s[n9 ~aIerline ~ - TEST HO~ ~iJize ~O' *olid ~e~ion ~ ~e~erllne · - MONITOR TUBE o - S~ER C~NOUT ce~ered over ~aterline trench. + - K~BOX NO SURFACE WATER -~- ~SEMENT PROPOSED ~CHFIE~ NO KNOWN CURTAIN DRAINS II I I I -. [XIS~NG ~CHRELD LEGAL: Eaqle River Volley ~enchettes Lot 24b ~[~ CONTRACTOR:N(A JOB~ 97-042 DATE: 7/28/97 I SCALE 1" = 30' ~ P.O. Box 773~4 EAGLE RIVER, A~ 99577 ~ o · (907) 694-S1~5 FAX: (~07) 694-3~97 EAGLE RIVER ENGINEERING SERVICES '- ~ P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 ERES Project No.: 97-042 Calculated By: LB Date: 7/28/97 Legal: Eagle River Ranchettes Lot 24b Single Family 3 Bedroom Dwelling TEST HOLE Deep Trench Subsur[ace Wastewater Disposal Field Water use at 150 gallons per bedroom = 450 gallons Percolation rate = 3.8 roinutes per inch Wastewater application rate = 1.2 gallons per day per square foot Required absorption area = 375 square feet Trench width 0/V) = 3 feet Gravel depth (D) = 4.5 feet Required length = Required absorption area / 2 / D Required length -- 375 / 2 Required length = 42 feet Total Excavation Depth = 6.5 feet / 4.5 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division 825 "L" Stree;~, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name $ f"~-v¢,,. /% ,-., Address Phone(s) Permit No. No. of Bedrooms LEGAL DESCRIPTION Lot 1 Bl°c~a~ Subdivision Township, Range, S~tion TANKS WELL DISTANCES SEPTIC ABSORPTION WELL TANK FIELD LOT LINE FOUNDATION ,~ / ~ ? / ,,~',,~ AS-BUILT DIAGRAM (Show location of well septic system, property lines, toundation, driveway, water bodies, etc,j SEPTIC [] HOLDING Capacity in gallons No, of Compartments TYPE OF SYSTEM ~"TRENCH [] BED [] W, DRAIN [] OTHER Depth to pipe bottom from Total depth from original grade original grade ~ FT ~', ,,..C'"' Gravel depth beneath pipe Fill added above original grade Gravel length ~'-0 FT Total absorption area J-J~-o SQ ET Numberolli~/es So~.~ng~ SQ ~CT Pipe meterial Date Installed WELLS [] PRIVATE [~' OTHER (Identilv) Classification (A,B,C) Total Depth ET Cased to Installer A Date InstaUed: IEMARKS: Eagle River Engineering Services ~. ~. ~; 7732;; Municipal and St~ ~r~ ~date; cmlily that this inspection was pedormed according lo all Date: ~'~/~ M U N I [; I P A I. I T" 0 F A N C H 0 R A G E Depa~tmeFrl of Health ~ Human Sel-vices 825 L Street, Anchorage, Alaska 99501 343-47R0 u N S I I E S E ~ E R P E ~ M I Permit Number: 880~04 Dat~* ];msued: 09/~:3/88 Upg~'aoe Encr ineer Designed Owner Name.~ STEVe'tN PON¥O Owner Address: 2251 SUNBURS"f CIRCLE ANCHORAGE. Al< 9950 1 Phone: 274-9282 Parcel ]:d: Loi egal: Subclivision: ~,~ VLE¥ R~Nc~HF.~'T~.S Lo~ S~ction: 7 Township~ 14N Range: 1W Lot Size 18000 ~sq. ft. op ac~es) Max Bedrooms: This Permit: 3 f'otal Capacity: 5 24B SEP'I'IC TANK: Minimu~ total septic tank capacity: 1~000 gallons. Each septic must have at leasl ~ compartments. Depth to top of septic ~ank(e) < 4.0 reo~ires insul, ation over tank(s). INFORFI D.H.H.S,. PRIO] lO 1S'I & 2ND INSPECTIONS BY ENGINEER, IF ~-~-lkd< OFFICE HOURS~ CALL 543-4681 AND LEAVE A MESSAGE. k;ONSI'RUCT PER ENGINEERS ATFACNED APPROVED DESIGN. ~d!._b ,~'ERMI'I' EXPIRES 12/31/88 AND VALID FOR A SINGLE ~:AMILY HOME. I C;ERI'IFY I'HAT: 1. I am Familiar with '[.r~e requirements ~or on-site sewers and wells as set ~ort. h by the Municipal.~ty o~ Anchora~e (MOA) ano the State ef Alaska. I will install the system in ac:c:ordanc:e with all MOA codes and requlations, and in compliance with the desimn criteria o~ this permit will adhere to all MOA and State o~ Alaska req~iremmnt, s ~or the set back distances ~rem any existing well, wastewate~ disposal system or public sewerage sys'~.em on this or any adjacent or nearby lot. I understand tha'~ this permit ~s valid for a maximum o£ 3 bedrooms. I ~ ...... .;nderstand that the capacity o~ the tetal eystem is 5 bedrooms and will require an additional permit DATE: STEVEN PONTO any enlargement gned: (Owner) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVI RONMENTAL PROTECTION 925 g Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: DATE PERPDRMED: LEGAL DESCRIPTION: 1 4 5 6 7 9 SLOPE SITE PLAN 10- 11 14 15- 16- 17- 18- 19- 20- WAS GROUND WATER ENCOUNTERED? IF YES, ATWHAT ' II''"''~" 7 0-3% Gross Net Depth to Net Reading Date Time Time Water Drop / ,, ~.~ ...z.~ ,,,,,... /~, ._.,,.:, ~-~. .2 .,~'~ ~ 3..~z /o ~,~ 6 -~ /_~ ~ ,, ~1~ ~o~,~ ~-5~ /.'~~ ~ /, ~f /~ /~,~ ~ - ~- ~' / - ~" COMMENTS ~,~ 4 w-~-~-~_- Eagle River Engineering Services PERFORMED BY: p..n. ~...x 77339~ CERTIFIED BY: Eagle River, Al( 99577 69~N5195 72-008 [6/79) PERCOLATION RATE ~ ,*/.d/(minutes/inch) TEST RUN BETWEEN ~ FT AND ~' ~-~ FT /5'o .5-,~_/~-,,~ ~4,~'~ ../' DATE:~ SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: LOT 24B Eagle River Valley Ranchettes GENERAL The well and septic plan are for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. All materials and workmanship shall meet the Anchorage Department of Health and State Department Of Environmental Conservation require- ments. Ail soil tests are advisory to the design and are to be verified or modified in the field by the engineer. Ail excavations and depths are advisory and are to be verified or modified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Oonservation requirements. 6. It is the reeponsibility of the owner to obtain ail necessary permits or easements and to locate any adjacent multi-family weiie. ?, The excavation is to be exactly in the area ehown on the site plan, any deviation requires engineer approval. It is aiwaye recommended that a surveyor locate the nearest lot line position and the location of any eaeements. TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of -the trench shall be level, plus or minus 1.5". The total depth of the trench excavation is not to exceed 7' at any point. 4. The sewer line is to replace the existing sewer line that leads to the existing pit. 5. The trench gravel is to be covered with typar fabric material. Soil Or combination of soil and extruded board insulation to a depth of 4' or equivalent is to be placed over the leachfield. 7· The area over the trench is to be finish graded to prevent ponding of surface water runoff. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS TOTAL DEPTH : 7' GRAVEL DEPTH : 5' TRENOH LEN~GT~45~RENOH WIDTH Soil Rating : 150 /~/f~ ~ -- RDAI)~ 133' ~ HSE FENCE' (+lOC LEACH ~ENCH ~ KE~BDX, +[0~+ ~ 10' UTIL, ESNT, ~VATERLINE EASEMENT EXISTING LEACH NEW LE~CH FIEL~ CLEANDUT - SCALD 1' = 30~ WELL AND SEPTIC SITE PLAN LEGAL~ LOT 24~, EAGLE RIVER VALLEY RANCHETTES D~NER, MR, STEVE PDNTD CDNTRACTBR~ CHUCK BARR EAGLE RIVER ENGINEERING SERVICES EAGLE RIVER, AK, 99577 694-5195 · : RE -R ANCHORAGE AREA BO IGH HH[~} ~' Depar{m~nf of Environmental Quality ~ !. ,'..: NSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME /~"~{/'~" ~'-~:'{f~'/~/V~7~)~7/'~//~/MAILING ADDRESS'/'/'4~"~ ~: ........ LOCATION ~Y~'~' ~/~/~/~ lEGAL · !-~ SEPTIC TAN K: '* ~: ' NUMBER OF ~?'~ DISTANCE '' '~ ~.~T~:]~/x~, MATERIAL g]/~ /~,-~'~..~ 3 COMPARTMENTS. -~F RD M WELL MANUFACTURER INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY GALLONS. SEEPAGE PIT: "i NUMBER OF PITS DIAMETER _ OR WIDTH ', LINING MATERIAL CRIB SIZE: DIAMETER BUILDING FOUNDATION ~/'//, NEAREST LOT L':iNE ~ ~ ~ : ;ADDITIONAL ,~BSORpT.ION LENGTH/7', DEPTH DEPTH DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SQ. FT. f,~;:.,:: - . , . BUILDING FOUNDATION -- CESSPOOL APPROVED CONSTRUCTION NEAREST LOT LINE OTHER SOURCES DISAPPROVED DEPTH NEAREST SEPTIC SEEPAGE SEWER LI NE TANK. SYSTEM REMARKS DISTANCE FROM: · -INSTALLED BY: : ?:~REMARKS: : .... ' DIAGRAM OF SYSTEM ' 1~66 ~,q L, ~?.r~,; DATE o~ "APPROVE • • <.) '1 8 9 70 7 Pie aU Municipality o :�'* c�b>org J � G On-Site Water and Wa fAte`r 'Pegi i a mill a f = = (907) 343- • 2017 UPM - S F E T Y alP !CT 30 2017 • ! 7'44 .% .� Certificate of On-Site S4: -ms Approv I c la o Parcel I.D. 050-223-20 Expiration Date: / 0 — 1. GENERAL INFORMATION: Complete legal description EAGLE RIVER VALLY RANCHETTES; LOT 24B Location (site address) 18732 Twenty Grand Road *Eagle River 99577 Current Property owner(s) Beth Yost Day phone 304-932-1855 Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: • Single Family (w/wo ADU) n Duplex Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ • Community Class Well ❑ Community ❑ Public Water System ® Public Sewer ❑ WaiverNariance request for: Distance: Received bye ..` ' Date: 10/3) /r7 COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5-2- * 3J5-.vf Waiver Fee $ Date of Payment /030/17 Date of Payment Receipt Number OCPJ 33 Receipt Number COSA# ( SC/�-1 3 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: Q44oCo'pp� In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system oQ Or ,g L j'N in accordance with the guidelines and regulations established by the Municipality of Anchorage and O .��,•••.. •.., Skl A industry practices. The reported results describe the condition of the system/s on the date's of the QO �`.-' i -. oU evaluation. Separation distances were measured to readilyidentifiable features. Hidden defects or • U encroachments may exist that were not identified during the evaluation. The operational life of all wells �* 9 TH Alf. ••,*v0 and septic systems depend upon a variety of variables, including but not limited to, soil conditions, '''''''' '''' ' '' 0 groundwater levels (that may fluctuate during the year), quality of construction (materials and VA workmanship),and the water usage of the family utilizing the system/s. These conditions can vary, and /.•.••••• Q are outside the control of GEG. Satisfactory test results do not guarantee future performance of the �►' •Je fr : d system/s; therefore, GEG makes no warranty(express or implied) regarding the future performance of (Q m 1=7953 .' a;�� the well or septic system. GEG makes no representation whether an alternative well or septic system Q 9 f �c¢4 can be installed on the property in the event either of the current systems fail to perform adequately in Q�fP,- •/.Q ,3 0• o the future. The content of this report is for the sole benefit of the person/party that retained GEG to Q04 Pr0fess;onc perform the evaluation. Reliance upon the information provided in this report by any other person or �0�pgooQ party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE KSystem #1 Approved for ,S bedrooms System #2 Approved for bedrooms Disapproved 0 GNpp,LITY op ii,.. Conditional approval for bedrooms, with the follo ,---"\-% s' tip 5 ions: �y'"vV,47 .ATE 0'.. CD IIIA ST AND =, PR" 11 6.RVICE.? By: ( 1 v'--\- v-ioi Original Certificate Date: j D")l(` F ---( The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: EAGLE RIVER VALLY RANCHETTES; LOT 24B Parcel ID: 050-223-20 A. WELL DATA AVVWU Well type If A. B, or C provide PWSID# Well Log (YIN) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N Total depth ft. Cased to ft. Casing height(ab. - ground) in. FROM WELL LOG AT I -` CTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RES • Coliform colonies/100 ml. Nitrate mg./L. Collected by: enic: ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 6/8-9/98 Tank size 1000 gal. Number of Compartments 2 Cleanouts (YIN) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 9/19/17 Pumper JR'S PUMPING SERVICE C. ABSORPTION FIELD DATA -BELOW EXISTING GRADE AT MT Date installed 10/1988 Soil rating (g.p.d./ft'ort Jbd))_ 150 System type TRENCH Length 50 ft. Width 3 ft. Gravel below pipe 4.5 ft. Total depth `7 ft. Eff. absorption area 450 ft Monitoring tube YES Depression over field NO Date of adequacy test 10/25/17 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 14 in. Water added 1298 gal. New depth 49 in. Elapsed Time: 120 min. Final fluid depth 35 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - -TESTED 1988 TRENCH ONLY 1998 TRENCH WAS NOT TESTABLE WHEN EVALUATED ON 9/19/17 FLOW SWITCHED TO 1988 TRENCH APPROXIMATLEY 5 WEEKS PRIOR TO PERFORMING ADEQUACY TEST INFORMATION ON 1998 TRENCH IS IN MOA RECORDS VIABILITY OF 1998 TRENCH IS UNCERTAIN. D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) "Pump on"level at in. "Pump off' level at •• •• wa er alarm level at in. • - - Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: AWWU Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main '•• sewer manhole/cleanout Sewer/septic service line Holding tank - containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line `10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main •10'+ Water service line '10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *PER LOUIS BUTERA, P.E. INSPECTION REPORT DATED 6/9/1998 40.001,1.•aii41 f 4 G. ENGINEER'S CERTIFICATION 4P4' \>:••'.... . 4'•'••+ +�7• • I certify that I have determined through field inspections and • ' '1As . i records that the above systems are in /1l review of Municipal ec y iq •toconformance with MOA COSA guidelines in effect on this �• ••• r date. 0 •' ! •. Gar ess _ Engineer's Printed Name JEFFREY A. GARNESS 10 --d, E— M ;*. / .Q ' .•. i0 10 4,- Date l0/16 // �0 PROFESSI�4♦♦ LICENSE �M111taus♦♦r #AECC884 (Rev.10/12/12) _ .v '.s9is'� x.73 4 0 , . I ‘' ` - • - ; . . 4 -'4 b I ji -- I 4,1' e C:ri.,1 % ij jP ' ��/ [1 • . i y. • • • -�.g". ASBUI LT SEWARD & ASSOCIATES LAND SURVEYING 6 9 4-0 8 2 9 HEREBY CERTIFY THAT- I HAVE SURVEYED THE ' i + SCALE_ +moo`s FOLLOWING DESCRI BED PROPERTY: •� OF A l ' % vie- ,i0,44107( ji,r4. iF40.d'4l-•S ‘e7-72'57-87 ~DATE- �'<<..-• •-r•-.4 4ND THAT NO ENCROACHMENTS EXIST EXCEPT AS r c ;•• INDICATED. !T I 5 THE RESPONSIBILITY OF THE .,:----‘----'2. : -. 49 L 7MYNER TO DETERMINE THE EXCiSTENCE OF ANY GRID: # :.. EASEMENTS, COVENANTS, OR RESTRICTIONS .t/ sP 1 f� -2.4,-z-- YHICH DO NOT APPEAR ON THE RECORDED S I- --- 1 a,.,., Mork 5.w,rd . PISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FE /�� # '. 15-6918 _ �p WY DATA HEREON BE US ED FOR CONSTRUCTION _ t Ay-.'• .. r )F FENCE LINES, OR FOR ESTABLISHING BOUND- Di�tAMllirl= kot :Ticx'a t- ° !RV LINES. ,d' likot i MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.# O~'~"~"~"~ ~'~) '~ HAA# ~-t 1. GENERAL INFORMATION Complete legal description Location (site address or directions) ;,~t#~., ~ '.~r;~ -- ~.,, ~ending agency ...... ., Mailino address · ", Day phone Day phone Address Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: "~ '~ TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- · lng to the legality and status of system. 4. ~ TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72~)25 (Rev, 1/91) Front MOA#21 = STATEMENT OF INSPECTION BY ENGINEER. AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. ..... Name of Firm EAGLE RIVER ENGII',~EER!Nr; ~ EAGLE Ri'v'E,'~,/-.~' ~257 ? Phone Address P.O. BOX 77329~ Engineer's signature ~_---- Date .. .' Approved for ~K~E bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments By: The Municipality of Anchorage Department of Health and Human Services [DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage R E C E ! ^~~ DEPARTMENT OF HEALTH & HUMAN SERVICES JUN '1 9 Environmental Services Division MUNICIPALITY OF 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907f~a~ALS~WCES DIVISION Health Authority Approval Checklist Legal Description: ~'-a,~/~ &/,/¢~' ~/~/,/<.,y /~c/;,~¢.~ ,/2~arcel I.D.: A. WELLDATA ~/,¢ Well type Log present (Y/N) Total depth Sanitary seal (Y/N) Date of test Static water level Well production WATER SAM~SU LTS: ~ate of sample: IfA, B, or C, attach ADEC letter. ADEc water sys Date completed ~ C~eight (above ground) Cased to / Wires properly protected (Y/N) FROM WELL L~ AT INSPECTION J g.p.m, g.p.m. Nitrate Other bacteria Collected by: SEPTIC/HOLDING TANK DATA Date installed ~L-~'-.¢~' Tank size Foundation cleangut-(Y/N), ~ ~ Depression (Y/N) ~ Date of PuM~iQ~;~ '~g.[' L,, Pumper ~/e ABSOR~iON'FiELD DATA ~- ~ -~, Date in~tallod ~- f- ~ ,~il ratin~ (~.p.d./~~ or ~/bd~) Length ~ / Width ~-jw Effective abs~[ion area "'~>~ ~ Date of adequacy test ~e ~ ~7~ Number of Compartments '~- Cleanouts (Y/N) Y High water alarm (Y/N) /'//.4' Gravel thickness below pipe Monitoring Tube present (Y/N) /v Results (Pass/Fail) /L/'~ /& System type "~,~' c b /'/'~C'~ Total depth ~'~ Depression over field (Y/N) ~ For -~ bedrooms ~ion field before test (in.); Immediately after gal. water added (in.): Fluid depth (ins) Minutes later: Absorpti6h rate = g.p.d. Peroxide treatment (past 12 months) (Y/N) If yes, give date 72-026 (Rev. 3/96)* D. LIFT STATION /4_///- Date installed Mauh~le/Accese~'Y/N) High water alarm level at* E. SEPARATION DISTANCES Size in gallons  "Pump off" level at* *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: ,p~¢~,)/c Septie~ank on lot Absorption field on lot Public sewer main On adjacent lots SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Property line /~ Absorption field Foundation Water main/service line '.7_,~ ~ Surface water/drainage +/~'~ Wefts on adjacent lots SEPARATION DISTANCE FROMABSORPTION FIELD ON LOTTO: Property line Surface water Curtain drain Building foundation ~/" Water main/service line Driveway, parkingAfehicle storage area ~-~-' Wells on adjacent lots ¢-.Z~ ' F. ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review, in conformance with MOA HAA guidelines in effect on this date. Signature ~ Date HAAFee $ ~ ~ ' 4~'~ Date Of Payment ~///?'/?"-~ Receipt Number ~'~// ('7' ~ ~/d~ Waiver Fee $. Date of Payment Receipt Number 72-026 (Rev. 3/96)* MUNICIPALITY O? ANCW. JK~,~u MUNICIPALITY OF ANCHORAGE DEPT. ~' DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECT~O~ ~ :'~],". :JiON 825 L Street - Anchorage, Alaska 99501 /:AR E~VlRO~ENTAb E~GI~EERI~6 DIVISION Telephone 264-4720 RECEIVED REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE Marvin & Shiela Moore 694-3620 MAILING ADDRESS c/o Area Inc. P.O. 249 Eaqle River, Alaska 99577 PROPERTY RESIDENT (If different from above) PHONE 2. BUYER Stephen Ponte PHONE MAILING ADDRESS Box 8022 Anchoraqe, Alaska 995~8 3. LENDING INSTITUTION Peoples Bank PHONE MAILING ADDRESS 4. REALTOR/AGENT Area Realtors Maureen Clayton MAILING ADDRESS P. O. 249 EaGle River. Alaska 99577 PHONE 694-9555 5. LEGAL DESCRIPTION Eaale River Ranch~ttes Lot 241~ STREET LOC.~TI ON 20 Grand St. Eagl~ Riv~.r. 6, TYPE OF RESIDENCE Ek SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS [] One [] Four E~ Two [] Five [] Three [] Six [] Other 7. WATER SUPPLY [] INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [~i COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTILITY depth (attach log if available.} 8. SEWAGE DISPOSAL SYSTEM [~ INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date _ _ If system is over two (2) years old .L ~' I 5 . an adequacy test ~s required [] PUBLIC UTI LITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, 72-010(3/78) DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSP ECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or [] Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ~]~'~PPROV ED FOR ,~' BEDROOMS [] CONDITIONAL APPROVAL (letter must accompan.v..~ertificate) [] DISAPPROVED LEGAL DESCRIPTION 72-010 (Rev. 3/78) July 11, 1979 Area Realtors, Inc. Parkgate Professional Building Eagle River, Alaska 99577 Attention: Morene Clayton EN'¢~RONMEN]AL P~:OT~CTION JUL I m?.Q RFCFIVED R&MNo. 951228 Re: Adequacy Test on Existing Sanitary, Sewer System; Lot 24B, Eagle River Ranchetts Subdivision, Eagle River, Alaska~ Dear Mr. Clayton: Per your request of July 9, 1979, we conducted a test of the sanitary sewer system on the above described property. 1000 gallons were pm~ped from the septic tank prior to the performance of the test on the seepage pit. During the test the liquid level in the seepage pit was monitored as 1000 gallons were removed and 1000 gallons were pumped back into the seepage pit to the inlet level. All liquid levels were measured below the top of the standpipe and are shown in the following table: Initial Water Second 24-Hour Total Reading Added Reading Reading Drop (gallons) 7 ' 1" lO00 4 ' 4" 5 ' 2" 10" The average specific capacity is 30.3 gallons per inch° After twenty four hours the liquid level was measured again at 5 feet 2 inches. It had dropped 10 inches. This indicates an average effluent acceptance rate of 303 gallons per day for the surrounding soils. If the 2 bedroom residence on the property is to house 4 people, the average load on the system can be expected to be 300 gallons per day. We can therefore conclude that the system is disposing of effluent at an adequate rate for a 2 bedroom residence. We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or if we can be of additional service to you. VerTtruly yours, ~ary/~. Smith Project Manager GAS/rm/AT&SI~A ~CHANICAL ENGINEER DAVID S~]ENK~kMP ~94~-9055 N G 1 R IN ClIANICAL ENGINEERS CIVIL ENGINEERS SRB 196X Eagle River, Alaska 99577 ~IVIL ENGIMEER ~OBERT A. S[~FER 694-2979 Maureen Clayton Area Realty Eagle River, Alaska 99577 :.' .' s,!vmo,,,,:,. ~R.,(,- ]' , RECEIVED. Reference Lot 24, Eagle River Ranchettes property, owneo by Mr. Marvin Moore. An.adequacy test was conducted on the sewer system (septic tank and seepage pit) located on the referenced property on 30 and 31 March 1979. The septic tank was pumped and verified to have a capacity of 1,000 'gallons. The seeoage pit appeared to b~ full .of water. I: had approxi- mately 800 gallons removed from the pit, The pit'was then recharged with 900 gallons of water which left water standing in the clean-out pipe. At the end of 24 hours, water was still standing in the clean-out pipe. As a result, it Can be concluded that: (1) the clean-out pipe has been shoved down into the crib making an accurate measurement impossible, or (2) the system has completely failed. It is recommended that, after break-up, excavation of the crib should be performed to determine 'the exact depth of the clean-out pipe. If it has been extended into the crib, it should be raised to the top of the crib and a new adequacy test performed. It is estimated that this could cost approximately $300 to $400, including the adequa%y test. If St is found that the system has i:aii~d, then an upgrading ef the system will be required. It is estimated that the system can be upgraded at a cost of approximately $1500, providing that soils are suitable for the installa- tion of a leaching trench. ~/t~OBkRT A. SHAreR, P.E CF: Mr. Marvin Moo~e Sun Realty (Darlene Nicholaysen) Municipality of Anchorage, Dept .C~2~'~7~ ?.~.,~/~ of Health & Environmental Protection ~:' ~~:./~/.. SAFECO Title Co.