HomeMy WebLinkAboutCURRIN LT 3Currin
Lot 3
#017-341-18
—aftv"ME I I A
DEC 14 2012
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • hftp://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP121043
PID Number: 017-341-18 ❑ New E) Upgrade
Name:
Spinell Homes, Inc.
ABSORPTION FIELD
0 Deep Trench El Shallow Trench E1 Bed El Mound
Address
1 900 W. Northern Lights,
Anchorage, AK 99517
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
344-5678
4
.45GPD/SF
11.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.0 Ft.
Gravel depth beneath pipe
8.OFt.
Subdivision4
C..V R-R+rJ
Block Lot
4-- 7-5
Fill added above original grade
2-4 Ft.
Gravel length
1 84 Ft.
Township Range Section
Gravel width
3Ft.
Beds: Number of Lines
I
Distance between lines
I Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
1,344Ft2
TWO
I >16Ft.
well
>100'
>100'
N/A
N/A
>25'
TANK O Septic ❑ S.T.E.P. ❑ Holding []Other
Manufacturer
Anchorage Tank
Capacity
1125OGal.
Surface Water
>100'
>100'
NIA
NIA
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
Steel
Two
NA
Foundation
>5'
>10'
N/A
NIA
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
Remarks
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPEMATERIAL Housetotank D3034 Tankto D3034
drainfield
Pomraning Excavation
Drainfield HDPE CO/MT D3034
Inspector MEA
BENCHMARK (Assumed elevation) 100.Oft
Inspection,
dates: t° 6/11/12 2 a 6/11/12
Location and description
p
V 6113/12 41h
Back Door Stoop.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineers Stamp
.•••� OF ••♦�
Conditional Approval:
Date
.•�P�'" '
�
4��
4L
=
�..... ....49th.. _...fi
0
I ..... .............. ................ •
MICHAEL E. ANDERSON .•�
'•_�%
♦� f•1,
No. CE -4381
�� TF •'•.. LSA•+=F�:
Approved
/
/rt/ • /q"* Date Ia 1 /2�
••.
♦�4 �e;
�.....
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
Permit No.: OSP121043 On -Site Wastewater Disposal System or Well Inspection Report
1 10' T. & E. ESMT.
S
. c9.
E 49th W -"-.t*
E. ANDERSON
PLAT N0. 83-548
CURRIN SUBDIVISION
LOT 3
42,354 S.F.
CURRIN CIRCLE
to
N
,--120.50' R=1,,,. _
Page 2 of 3
PID No. 017-341-18
A B
S1 28.1' 23.4'
S2 27.5' 31.2'
C4 19.9' 37.1'
C6 40.8' 42.5'
M1 48.3' 73.3'
M2 57.9' 76.0'
FSV 29.6' 39.5'
C5 53.9' 79.7'
C7 182.6' 181.2'
WellH,0
10
lHome
F
\
-'
1S3M
G
uTERNA _r c
ntez Treatment System
W/8A0'WL=9'vsDepWid.
meaapir. Trench
FSV\
THB®��
ry0
N0�.
�
0
�
\\\CM2 Mt
,L7°
LEGE
tP
M1 — Monitor Tube
G
2
FCO — Foundation Clean Out
TH — Test Hole
C5 — Clean Out
FSV — Flow Splitter Valve
S7 — Septic Vent
T. & E. ESMT.
PLAN AS -BUILT
SCALE V = 50'
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP121043
X
PID No. 017-341-18
98.2
LO
U
42' (Trench Length)
42' (Trench Length)
PROFILE AS -BUILT
No Scale
92.7
114
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
MEMORANDUM
DATE: December 14, 2012
TO: Jeff Poet
FROM: Mike Anderson, P.E.
SUBJECT: Lot 3, Currin Subdivision
Septic System Permit No. OSP121043
Substantial grading was completed on the lot prior to placement of the new absorption
system. We discussed the alignment of the new absorption trenches during the first
inspections and agreed placement of the trenches in a north/south direction was
acceptable. The surface of the lot in the area of the new trenches was virtually flat at
the time of construction. The entire absorption area remains in the accepting soils
identified during the test hole exploraton and percolation testing.
Alpine Drilling & Enterprises
Well Log
Permit Number: #SW 121048 Date of Issue: 5-21-12 Parcel Identification Number: 1734118000
Date Started: 6-20-12 Date Completed: 6-22-12 Is well located at approved permit location? x Yes ❑ No
Legal Description: Currin Lot 3
Property Owner Name & Address: Grove Lawrence & Cynthia A - Spinnel Homes
PO Box 222253
Anchorage, Alaska 99522
Borehole Data:
Depth (ft)
Method of Drilling x air rotary ❑ cable tool
Soil Type, Thickness & Water Strata
From
To
Casing type: steel
Stick-up
0
2
Wall Thickness:.250 inches
sill
2
4
Diameter: 6 inches Depth: 287 feet
Liner Type:
sandy silty gravel
4
85
Diameter: inches Depth: feet
gravelly sill
85
91
Casing stickup above ground: 2 feet
Static water level (from ground level): 243 feet
sandy silty gravel 91 105
silt
105
121
Pumping level: 285 feet after
silty gravel
121
182
2 hours pumping 20 gpm
Recovery Rate: 20 gpm
silt
182
201
Method of Testing: air li t
gravelly silt
201
215
Well Intake Opening Type:
gravel
215
230
x Open End ❑ Open Hole
gravelly silt
230
235
❑ Screened Start feet Stopped feet
❑ Perforations Start feet Stopped feet
silty gravel
silty water sand & gravel
235
261
261
263
Grout Type: bentonite Volume: 2 bgs
Depth: Start 0 feet Stopped ? feet
Pump: Intake Depth feet
gravelly silt 263 282
water sand & gravel
282
287
Pump size hp Brand Name
Well Disinfected Upon Completion? x Yes ❑ No
Method of Disinfection: chlorine tablets
Comments:
Well Driller: Alpine Drilling & Enterprises
PO Box 110496
Anchorage AK 99511
Development Services Department
Building Safety Division
�r On -Site Water & Wastewater Program *A9
4700 Elmore RoadP.O. Box 196650Mark Begich Anchorage, AK 99507
Mayor www.muni.oro/onsite
(907)343-7904
Pump Installation Log
Well Drilling Permit Number: SW 121048
Parcel Identification Number: 1734116000
Legal Description
Lot 3 Currin Sub.
Pump Installation Date: 11114/2012
Pump Intake Depth Below Top of Well Casing: 272
Pump Manufacturer's Name: crundfos
Pump Model: 15 SQE-15-290
Pump Size 1 112 hp
Pitless Adapter Burial Depth: N/A feet
Pitless Adapter Manufacturer's Name: N/A
Pitless Adapter Installer: rdA
Well Disinfected Upon Completion? 0 Yes ❑ No
Method of Disinfection: chlorine tablets
Comments:
Pump Installer Name: Aarow Pump & Well Service, LLC
P.O. Box 110496
Anchorage, AK 99511-0496
feet
Date of Issue: 5/21/2012
Property Owner Name & Address:
Lawrence & G/nthia Gromt (.Spinel) Homes)
P.O. Box 222253
Anchorage, AK 99522-2253
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121043
Tax Code Number: 01734118000
Work Type: WellSeptic Initial
Permit Effective Dates: May 21, 2012 to May 21, 2013
Design Engineer: ANDERSON ENGINEERING
Subdivision: CURRIN
Site Legal Address: CURRIN LT 3 G:2937
Owner/Address: GROVE LAWRENCE & CYNTHIA A
PO BOX 222253 ANCHORAGE AK 995222253
Site Mailing Address: 5020 Currin CIR, Anchorage Lot Size in Sq Ft:
Total Bedrooms:
This permit is for the construction of:
42354
4
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Receive
Issued
C 0 1 rev-ses 4,kk &00"�1-e1d.
Municipality of Anchorage
Development Services Division
On -Site Water and Wastewater Program
ftelp"tt"�'t
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSP121127 COSA#:
PID#: 017-341-18
Legal Description: Currin Lot 3
Engineer: Anderson Engineering
Applicant: Lawernce & Cynthia Grove
Permit#: OSP121043
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the slope steeper than 25% has been approved. The approved separation distance is 7 feet.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
® The affected adjacent property owner(s) have been given a notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
❑ Adjacent properties are not affected by this waiver.
............................................................................. 0.
Waiver is Granted: X Waiver is not Granted:
Date: b l07 /,2 Approved by!l
Name of Reviewer
................... Nunn............... e .............. women ........... ..........
Rec#: 02056G Amount: $200.00 Date Paid: 6/11/12
**** VARIANCEMAIVER REVIEW ****
MUNICIPALITY OF
F
Community Development Department
Development Services Division–�
On -Site Water & Wastewater Program
Mayor Dan Sullivan
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcell.D. 017-341-18
Property owner(s): Spinell Homes, Inc.
Phone: 907-343-7904
Fax: 907-343-7997
Day phone: 344-5678
Mailing address : 1900W. Northern Lts. Blvd., Suite 200 Anchorage, AK 99517
Site address: 5020 Currin Circle Anchorage, AK 99516
Legal description (Sub'd., Block & Lot): Currin, Lot 3
Legal description (Township, Range & Section)
Lot Size: 42,354 Sq. Ft. Number of Bedrooms: Four (4)
THIS APPLICATION IS FOR: THIS APPLICATION IS AN:
(®all that apply) Initial X
Absorption Field X
Upgrade ❑
Septic Tank X
Renewal ❑
Holding Tank ❑
Privy ❑
Private Well
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: x'70 tel'] — Waiver Fees:
Date of Payment: C129- Date of Payment:
Receipt Number: Ci'1 i`l b Receipt Number:
Permit No. 0`J�t� )�y3 Waiver No.
C:\Users\AndEng\Desktop\Mike\Currin\Permit Application Lot 3.docC:lUsers\AndEng\Desktop\Mike\Currin\Permit Application Lot
3.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
April 2, 2012
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 3, Currin Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 3, Currin Subdivision intends to construct a new four-bedroom home
on the lot. We are therefore requesting a permit be issued for the construction of a new
well and septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed well and septic
system along with the alternate site. Also identified on the plans are the existing wells
in the area and septic systems on surrounding lots. No conflicts exist between the
proposed septic system and well or septic systems and wells on adjacent lots.
Drainage arrows are shown on the site plan showing the grade and direction of flow on
the lot. The drainage pattern will not be changed as a result of this project.
The test hole placed on the lot in the area of the absorption trenches and alternate site
indicate silty sand with gravel (SM). The percolation rate of the soil was determined to
be 12 minutes per inch. No groundwater was found during the placement of the test
holes and none was noted during the monitoring period. An application rate of .8
gallons per day per square foot was used in the design of the absorption system. We
are proposing to place a new 1,250 -gallon septic tank and 2-38' long by 5' wide by 4'
effective depth absorption trenches to treat and dispose of the effluent generated in the
house. The elevation of the distribution line in the absorption trench will be 3' below the
surface and the total depth will be 7'. A flow splitter valve will be placed to insure even
flow to each trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed
over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the septic system slopes to the southwest
at a shallow grade with some cross sloping from the east. The new trenches will be
Lot 3, Currin Subdivision
April 2, 2012
Page Two
constructed parallel with the contours of the slope as much as possible in conformance
with Municipal requirements. The new septic system will be constructed a minimum of
100' from all wells and any surface water and 10' the proposed and existing water
services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, Q
Michael E. Anderson, P.E.
Attachments
0 49th
MICHAEL E. ANDERSON
. No. CE -4381
I I
I i ,
I 1 I
I I I
I I I
(\J I I
I
TRACT A
I
I I
I I
I I
I I
I I
I I
c I I
C-------------------------------------------------------------------------------
---------------------- -------------------------------------------
__}__r______
; 1 1
I I 1 I
I I I I
1 I n
I i E.isling WNI
f 2A
\ / I • 1
\ / 1 hotwa wl
\ � I
Eistin9 "I
1
1
I I
I0 �
P
1------------
5 1
1 ^ I
1 LII I
I
1 I
I
I.
, I
, I
' 1 I
1 I
I I
1
1 v 1
I I
, I
1 I
, I
1 I
I
II
�.•'E OF q
vc `p...................
� G�: :' 1♦ GRIFFIN
i
49th ♦�
% ............................... .....
.........ICHA..LE.............ON.Q AREA MAP
�'; MICHAEL E. ANDERSON : � %
4
%♦♦ �••.• NO. CE-4361 .'�'_/
♦♦TF •.N-3����
♦44? P .......... P� SCALE 1" = IDD'
fh ,N 5;,����
Col
PLAT NO. 83-548
CURRIN SUBDIVISION
LOT 3
42,354 S.F.
/ CURRIN CIRCLE
N ` \
700.00.
Cis
^ ° I
Proposed Well
r
✓, m i u
THA
_—
is/
u o' j
Four Bedroom / �o /
\\ \ Home / ��• 100•
5°
\ 1,250 Gallon'-
\ °
y
4�2F•
Septic Tank sy \f i
\ zco \+ 2-38-Long_x 5' Wye_—
rsv
\ Ca 4• Effective th
\ o adsorption Trenc es
\ S N Aavenlex ireot ent system ti
THB}• wme
,
co N"o 48 Efroctrre
Existing well
'�
enptn
pe
®
MI \i b
s N 1 i
Existing Well
\
/ P
/ 20' T. & E. ESMT. \\
/
92'
\\
NOTE:
ScWater is Within ystem.
th
Nit
Any Portof New Septic S
---.��+�-�.........,q♦.
••
LEGEND
�: ��
MT - Monitor Tube
FCO Foundation Clean Out
;l
49th °:
-
TH — Test Hole
�.....: .............. ..... :.....�
CO - Clean Out
%Kd
FSV - Flow Splitter Valve
i.... v-- ...
��'....DCHAELE.AN........N-'"..
:MICHAEL E. ANDERSON �.
'
SITE PLAN
�I u, No. CE -4381 �
�♦ Thr, •.
`jJ
04w
SCALE 1" = 50'
�114111,MOFESSI����
LOT 3, CURRIN SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS
Four Bedroom Home Deep Trench System
Perc. Rate: 40 Min./inch 1,250 Gallon Septic Tank
Application Rate: .45 GPD/SF 8' Drainfield Rock
4 Bedrooms' 150 GPD/Bedroom = 600 SF Absorption Area
600 SF/.45 GPD/SF/16 SF/LF = 83.3 LF Trench Length
THEREFORE: Construct 2-42' Long x 3' Wide x 8' Effective Depth Absorption Trenches.
Flow Line Elevation in Trenches to be 3' Below Original Ground Surface. Total Depth to be
11' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank. Place Flow Splitter Valve to Insure Even Flow to Each Trench.
3'
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
i�
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock. 0 ......
Minimum 4' Separation From Groundwater. 0011/1
�......
Minimum 100' Separation From Private Wells in the Area. � m'
Minimum 100' Separation From Surface Water or Streams. ��I
M.
MICHAEL E. ANDERSON
No. CE4381
13
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 3, CURRIN SUB
PERFORMED FOR: SPINELL HOMES
DATE: 5/30/2012 PROJECT No.:
PARCEL ID#: TECHNICIAN:
DEPTH
(feet)
I
2
READING
TEST HOLE B
OB/OG
NET TIME
(MINUTES)
3
1F YES @ WHAT DEPTH? - ,S
TEST HOLE PRESOAKED PRIOR TO TESTING:
DEPTH OF WATER AFTER MONITORING: NONE L
ML
4
DATE OF MONITORING: 6/4/2012 0 0
BROWN SANDY SILT
SOME GRAVEL
5
30
5.75"
6
3
7
5.25"
8
4
9
30
6.00"
M. ANDERSON
SLOPE
e't :•-
y *? 49MI
:MIc►ANDM
s : 4361
feP •..... X.
I!._'fdrrs tOt*.
Yt
SITE PLAN
SEE SITE PLAN r
x
i
10
READING
WAS GROUND WATER ENCOUNTERED? NO
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
1F YES @ WHAT DEPTH? - ,S
TEST HOLE PRESOAKED PRIOR TO TESTING:
DEPTH OF WATER AFTER MONITORING: NONE L
11
3:00
DATE OF MONITORING: 6/4/2012 0 0
I
17
1
COMMENTS: Test Hole Pre Soaked Prior to Test.
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
6/1
1
3:00
5.00"
2
3:30
30
5.75"
.75"
3
3:32
5.25"
4
4:02
30
6.00"
.75"
5
4:04
5.50"
6
4:34
30
3.25"
.75"
PERCOLATION RATE:: 40 (MIN/INCH) PERC. HOLE DIA.. 10° (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON, CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 6/2/2012
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 3, CURRIN SUB
PERFORMED FOR: SPINELL HOMES
DATE: 3/1/12 PROJECT No.:
PARCEL ID#: TECHNICIAN: B. SCHILLER
DEPTH TEST HOLE HOLE AA
(feet)
1 OB/OG
2
3 SM
4 BROWN SILTY SAND
5
6
7
8
9
SLOPE
49IN*
_
AEL L ASN: CQ ;
C,E*4381- .ate
SITE PLAN
SEE SITE PLAN
u
i
14 BOH
15-
16-
17-
18-
19-
COMMENTS:
516171819
COMMENTS: Test Hole Pre Soaked Prior to
DATE
READING
WAS GROUND WATER ENCOUNTERED? NO
10
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
IF YES Q WHATDEPTH? - „S
1
4:25
DEPTH OF WATER AFTER MONITORING: NONE
11
DATE OF MONITORING: 4/2/12 O 0
14 BOH
15-
16-
17-
18-
19-
COMMENTS:
516171819
COMMENTS: Test Hole Pre Soaked Prior to
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
3/1
1
4:25
4.0"
2
4:55
30
6-1/2"
2-1/2"
3
4:56
4-1/4"
4
5:26
30
6-3/4"
2-1/2"
5
5:27
4-1/8"
6
5:57
30
6-5/8"
2-1/2"
PERCOLATION RATE: 12 (MIN/INCH) PERC. HOLE DIA. 8° (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON, CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 4/2/2012
CoJ
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 F
June 6, 2012
Municipality of Anchorage
5 a[ of 11'a—+
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 3, Currin Subdivision
Absorption Trench to Slope Waiver
Dear Onsite Services Engineer:
The absorption trenches on Lot 3, Currin Subdivision are proposed for construction
near a 33% slope which extends onto the neighboring property for a total drop of
approximately 14'. This slope only slightly exceeds the allowable 25% break in grade.
The end of the closest trench is 7' from the top of the slope. The other active trench is
13' and the alternate site is 11.5' from the top. In every case the 25% imaginary slope
when extended from 2' above the effluent distribution line does not daylight to existing
ground. We therefore request a waiver be issued allowing the trenches to be placed at
the proposed locations.
Sincerely,
W44_j � F'-a��
Michael E. Anderson, P.E.
001
• �33ry/y�111
���* }
a off
l
0 V00
s-' S'�T •.w
4a
00
VA
asoo }sioM
0
`o
adois o} }sasoo
youaal aaddn
In
LO
1
o Z
CD w
I
5; U)
d) C (J�
m w
aui� A}jadoad
N
D (n
cn o Q
o
LD
z
C-
w
Ln� m
1p
o
� J
o U
I
Ln
1
0
N
L
O
Ln
O
O Ln O
M N N
Ln
O
u1
0
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 3, CURRIN SUBDIVISION
GENERAL:
1. The scope of this project includes the procurement and placement of a new
1,250 -gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of 2 new 38' long X 5' wide X 4' effective depth
absorption trenches at the location also shown on the Site Plan. The
distribution line in the trenches will be placed at 3' below the existing ground
surface. Total depth of the trenches will be 7' below the existing ground
surface. The new absorption trenches and septic tank must be placed a
minimum of 100' from all private wells and any surface water in the area and
10' from the water service line proposed for the lot. A minimum of 3' of cover
is required over the absorption trench and 4' of cover over the septic tank. A
flow splitter valve must be placed to insure even flow to each trench.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
4. Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Building Safety Division On -Site Water and Wastewater Program
for system installations. Owners installing their own systems must receive
prior approval from the On -Site Water and Wastewater Program. before
beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250 -gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 3, Currin Subdivision
April 2, 2012
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
6. Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. All pockets of unacceptable materials must be removed and
replaced.
Lot 3, Currin Subdivision
April 2, 2012
Page 3 of 3
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as -built of the completed system.
• Municipality of Anchorage
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 017-341-18
1. GENERAL INFORMATION
Complete legal deesseription Currin, Lot 3
Location (site ad -dress) Currin Circle
Current Property owner(s) Spinell Homes, Inc. Day phone 344-5678
1900 W. Northern Lights Blvd. Anchorage, AK 99517
r/g 9 70 1j'2 ;#
RWSH! Ay
o N
a a �
30
Expiration Date: J�
Anchorage, AK
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
E] Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
Four
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
0
Individual
0
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for:
Received by: " C_ Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ %sem 51 ^ )2w k Waiver Fee $
Date of Payment l (ci1a!2� Date of Payment
Receipt Number 01 --) aS G Receipt Number
COSA # (YDG I a 1 S1 a Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for A_ bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for
Phone 522-7773
bedrooms, with the following stipulations:
By: K/ �J Original Certificate Date:
The Munici ality of chorege Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional dull engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet E - , c
If more than 1 septic system is on the lot:
COSA Checklist # _of _
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Currin Subdivision, Lot 3
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed 6/22/12 Sanitary seal (Y/N) Y
Total depth 287 ft. Cased to 287 ft.
FROM WELL LOG
Date of test 6/22/12
Static water level 243 ft.
Well production 20 9-13 m_
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate 1.71 mg/L
Arsenic 14/-0 ug/L Dateofsample: 12/11/12
Parcel ID: 017-341-18
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) >18 in.
AT INSPECTION
ft.
Collected by: M. Anderson
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 6/11/2012
Tank size 1,250 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N)
Date of pumping New Pumper Construction
C. ABSORPTION FIELD DATA
N
Date installed 6/11/12 Soil rating (g.p.d./ft2 orft2/bdrm) .45 GPD System type Deep Trench
Length 84 ft. Width 3 ft. Gravel below pipe 8 ft.
Total depth 13-14 ft. Eff. absorption area 1,344 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at in.
Datum
E. SEPARATION DISTANCES
WELL ON LOT TO:
Size in gallons Manhole/Access (Y/N)
"Pump off' level at in. High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
Septic tank/lift station on lot
>1 00'
Absorption field on lot
>100'
Public sewer main
N/A
Sewer /septic service line
>25'
Animal containment areas
>50'
SEPTIC/HOLDING TANK ON LOT TO:
On adjacent lots >100'
On adjacent lots >1 00'
Public sewer manhole/cleanout N/A
Holding tank N/A
Manure/animal excrete storage areas >100'
Building foundation >5, Property line >5'
Water main > 10' Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line >10' Building foundation >10'
Water Service line >10' Surface water >100'
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 12/19/2012
COSA brown sheet 10-10-12.doc
Absorption field >51
Surface water >100'
Water main
>10'
Driveway, parking/vehicle storage >1 0'
PLAT NO. 83-548
CURRIN SUBDIVISION
LOT 3
42,354 S.F. CURRIN CIRC`=
in
a
3
6.+ v 1 L. V 11 lql7 L/ L- l r%I L -
SCALE: 1"=20'
GASTALDI LAND
SURVEYING, LLC
JEFF A. GASTALDI, R.L.S.
2000 E. DOWUNG RD., SUITE 8
ANCHORAGE, ALASKA 99507
PHONE 248-5454
GRID DATE
SW2937 7/31/2012
F.B. JOB N0.
CURRIN3
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE.
♦'*wsraoo
OF A •�
.�•� .`
49TH
y� eeseoe.. eseee
•.p . Jeffery A. Gastaidia
LS -6091 •.'� m�AlF
At
16� 40
apr .ee .• Pd .
def®rsVAss* s
11 40'