Loading...
HomeMy WebLinkAboutCROSS VIEW ESTATES BLK 2 LT 28Ceoss View Estates Block Lot #015-221-86 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP121091 01522186000 WelISeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: June 07, 2012 to June 07, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: CROSS VIEW ESTATES Site Legal Address: CROSS VIEW ESTATES BLK 2 LT 28 G:2737 Owner/Address: H2L INVESTMENTS LLC 633 E 81ST AVE ANCHORAGE AK 995180000 Site Mailing Address: 5058 HERITAGE HEIGHTS DR, Anchorage Lot Size in Sq Ft: 45731 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~//~J,~ MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan Phone: 907-343-7904 Fax:907-343-7997 ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0t5-221-86 Property owner(s): H2L Investments Day phone: 350-1860 Mailing address: 633 East 81st Avenue Anchorage, AK 99516 Site address: 6070 Heritage Heights Drive Anchorage, AK 99518 Legal description (Sub'd., Block & Lot): Cross View Estates, Block 2, Lot 28 Legal description (Township, Range & Section) Lot Size: 45,73t Sq. Ft. Number of Bedrooms: Four (4) THIS APPLICATION IS FOR: ([] all tha~ apply) Absorption Field X Septic Tank X Holding Tank [] Privy [] Private Well X Water Storage [] THIS APPLICATION IS AN: Initial X Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: __ Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. C:\Users~AndEng\Desktop\Mike\Cross View Estates~Permit Application Lot 27 H2LdocC:\Users~AndEng~Desktop\Mike\Cross View Estates\Permit Application Lot 27 H2L.dec May 22, 2012 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~e~: Lot 28, Block 2, Cross View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 28, Block 2, Cross View Estates Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trenches and alternate site indicate silty sand with gravel (SM). The percolation rate of the soil was determined to be 27 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .6 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and 2-35' long by 3' wide by 8' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4' below the surface and the total depth will be 12'. A flow splitter valve will be placed to insure even flow to each trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the northwest Lot 28, Block 2, Cross Point Estates Subdivision May 22, 2012 Page Two at a 5% grade with some cross sloping from the east. The new trenches will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area, The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments I ji LOT 29, BLOCK 2 UNDEVELOPED LOT 5, BLOCK 4 HERITAGE HILLS UNDEVELOPED CROSS PLAT NO. 2006-171 VIEW ESTATES SUBDIVISION LOT 2a, BLOCK 2 49,439 S.F. NOTE: NO Areos of ExcesSive Slope or Surfoce Woter ore Within 100' ol Any Port of the New Septic System, / G. SLAB / EL. = 656' / co / 'our / Home NOT~: The 100' Well Radius end oll Easements Within 20' et the New Septic System Must be Stoked by o Reglstered Lend Surveyor Prior to Construction. STORM DRAIN ESMT. N 89'53'42"E 194.67' I~'~--ELEVATIONS BASED ON 1972 NGS DATUM (TYP) SITE PLAN SCALE 1' = 50' 2-55' Lon9 x S' Wide x 8' Effechve Depth Absorption Trenches LEGEND MT - Monitor Tube FCO - Foundotion Cleon Out TH - Test Hole CO - Cleon Out 2C0 - Double Cleon Out FSV - Flow Splitter Volve LOT 28, BLOCK 2, CROSS VIEW ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 28 Min./Inch 1.250 Gallon Septic Tank Application Rate: .6 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/.6 GPD/SF (Application Rate) = 1.000 SF Absorption Area 1.000 SF/16 SF/LF = 62.5 LF Trench Length THEREFORE: Construct 2 - 35' Long x 3' Wide x 8' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 12' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Place Splitter Valve to Insure Even Flow to Each Trench. Natural Backfill Geotextile Fabric 4" Perforated 6" L....)- PVC (Holes Down) Drainfield Rock 3' I TYPICAL DEEP TRENCH SECTION (No SCALE~ ,*'~. .......... NOTE: Grade Area Over Trench to Drain Away. ,, .~ Minimum 6 Separation From Bedrock. ,%'::'..'/.....t.......4....~....~.;.....& Minimum 4' Separation From Groundwater. ~_..~.~ Minimum 100 Separation From Wells in the Area. ,.~. c ^~ ~,~o~ ..-'~, MJnimum 100' Separation From Sufiace Water or Streams ~% No ~700 DEPTH (feet) 1 2-- 3 4-- 5 6-- 7-- 8 9-- 11 20. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6050 SOILS LOG - PERCOLATION TEST ] LEGAL DESCRIPTION: PERFORMED FOR: DATE: 5/10/2012 PARCEL ID#: LOT 28, BLOCK 2, CROSS VIEW ESTATES SUB. PROJECT No.: TECHNICIAN: OB/OG SILTY SAND WITH GRAVEL BOH @ 18' HARDING HOMES OF ALASKA [vi. ANDERSON SLOPE SITE PLAN SEE SITE PLAN WAS GROUND WATER ENCOUNTERED? NO DEPTH OF WATER AFTER MONITORING: NONE I 0 °~o ~ DATE OF MONITOKING: 5/17/2012 p ~ DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 5/11 1 11:14 .56" 2 11:44 30 1.75" 1.19" 3 11:45 .63" 4 12:15 30 1.75" 1.12" 5 12:16 .50" 6 12:46 30 1.62" 1.12" PERCOLATION KATE: 27 (MINfiNCH) PERC. HOLE DIA. 8" ~INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERI~ORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTE?Y THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES 1N EFFECT ON THIS DATE: 5/22/2012 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 28, BLOCK 2, CROSS VIEW ESTATES SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250-gallon septic tank at the location shown on the Site Plan. Work also includes the construction of 2 new 35' long X 3' wide X 8' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trench will be placed at 4' below the existing ground surface. Total depth of the trench will be 12' below the existing ground surface. The new absorption trench and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area and 10' from the water service line proposed for the lot. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. A flow splitter valve must be placed to insure even flow to each trench. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Building Safety Division On-Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On-Site Water and Wastewater Program. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250-gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 28, Block 2, Cross View Estates May 22, 2012 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below the distribution line must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfieid rock for a 5' wide trench. All pockets of unacceptable materials must be removed and replaced. Lot 28, Block 2, Cross View Estates May 22, 2012 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. oe d 2OIb •` _ Municipality of Anchorage J Vl-/ `� -2S On-Site Water and Wastewater Program (907) 343-7904 SAF ETY Certificate of On-Site Systems Approval Parcel I.D. 015-221-86 Expiration Date: 3 — ` " / g 1. GENERAL INFORMATION Complete legal description Cross View Estates Block 2 Lot 28 Location (site address) 5058 Heritage Heights Dr. Current Property owner(s) Angel & Maritza Cardenas Day phone Mailing address 5058 Heritage Heights Dr. Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: s Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received b•• ;... /.L _ Date: 1/6//8 COSA to be released to the engineer,unless otherwise requested by the e 0 -er. COSA Fee $ `J o�s Waiver Fee $ Date of Payment /NM Date of Payment Receipt Number (3qb ct6 Receipt Number COSA# 0566/00 i Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can vie estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 1/3/2018 •eco.• ':yrs 6. DSD SIGNATURE t' ' 4 .. �1 System#1 Approved for bedrooms 4eet System#2 Approved for bedrooms c�9•, CE-8149, Disapproved i�� APOF• FSSIONP ^r Conditional approval for bedrooms, with the following stipulations: -' ,.\�Ya�I I a ON-SITE ‘1,:'-,• WATERA,%o WASTFWATERND a' " : PROGRAM �_= •olfF ASO. 'vrsEtiv • ----!—_-- / 4 B . J I Original Certificate Date: /— 3 /2 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet J . If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Cross View Estates Block 2 Lot 28 Parcel ID:015-221-86 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/29/2012 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 227 ft. Cased to 227 ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 6/29/2012 12/8/2017 Static water level 150 ft 148 ft. Well production 15 g.p.m. 3.7 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 2.57 mg/L Arsenic ND ug/L Date of sample: 12/8/2017 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 8/8/2012 Tank size 1250 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N/A Date of pumping 12/14/2017 Pumper A+ Home Services C. ABSORPTION FIELD DATA Date installed 8/8/2012 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.6 GPD/SF System type Deep Trench Length 70 ft. Width 3 ft. Gravel below pipe 8 ft. Total depth 12 ft. Eff. absorption area 1,120 ft2 Monitoring tube Y Depression over field N Date of adequacy test 12/8/2017 Results(Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 45/7 in. Water added 610 gal. New depth 48/10 in. Elapsed Time: 120 min. Final fluid depth 45/7 in. Absorption rate >= 600+ g.p.d. N Any rejuvenation treatment (past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Survey on file. G. ENGINEER'S CERTIFICATION P OF A .\�� I certify that I have determined through field inspections and Ale tij.• review of Municipal records that the above systems are in *; ,.• TH A'\ •*7 conformance with MOA COSA guidelines in effect on this date. ,••••`4!0t? • •• 0 Engineer's Printed Name Steven Pannone ` ••.Steven 1. '' ne • 1/3/2018 '• CE-8149 ,,��� Date ��19f'• ,��'�rr COSA canary sheet_2-6-15.doc