Bore, hole Data:
Soll '1~1~, T'aickae~s & Wat~ S~a~a
at/¢l~Up 0 2
o~a~m 2 3
~andy grovel 3 4
gmvel~ silt 4 36
stay sony grovel wet 36 40
gm~l~ s~t 40 53
s~ grovel 53 59
g~vel~ san~ si~ 67 101
cobbly ~ty gmvel wet ~01 ~07
~bb~ gmvelly slit d~ 107 122
~bb~ san~ ~ gravel ~0 ~22 . ~54
~al D~pdon: R~uht of. WaY ac,ui~ion Plat T~ct ~
~~er~ame&Add~= T~edini Pe~ Pa~emhip ~,~ i : ~
800 E Dimond Suite ~5
~ora~e, Alaska 99515 .... ,,,
Depth (~) Method of Ddl~g ~ ~ ~,,,,~ ~bl¢ ~o1
F~m To
i [[
Diameter:._6 [uci~es Depth: 146 feet
Llacr Type:
Casing sticlmp above ground: _2 feet
Static water level (f~om grotmd level): 9/feet
Pumpiag level: ~50 foot after
_2 hours pumping ~ gpm
R~CoY~W,]~t ,e: 10 gpm
Method of T~di~.. otrltt~
Well ~takr. Opening
[~] Open End ['10ytn Hole
[] Screened S~art feet Stopped feet
D Perforations S~art , feet Stopped feet
Grout Type: ~entonite3manules Volume: I bg
Depth: StanO feet
Pump: Intake Depth feet
Pump size hp Bt, md Name .
Well Disinfected Upon Completion? [] Yes [] No
Method ofDisinfectiom chlodn~ tablets .
Comment~: see follo~ing pump test
PO Bo~ ~ 10406
Anchorage Alaska 9951
A~¢aOon: The wort drillcrshMI provideawcU Ioglotbe ptoper[yo~met wi~[a 30 daysofcempletlonandt~eprop.nty
Municipality of Anchorage
T Mark Begich, Mayor
Building Safety Di%islon
P.O. Dox 196650 • 4700 Bragaw Street
Anchoragc, Alaska 99519-6650 • (907) 343.8301 • Pax (907) 343.80-00
March 31, 2004 http://ex-e.n,uni.org
Tuxedni Park Partnership
800 E Dimond Suite 3-545
Anchorage, AK 99515
Subject: On -Site Water and/or Wastewater Permit.
Permit Number: SW030079
Legal Description.tWg—ht of Way Acqutstti6nTractB3'
5•D
Dear Tuxedni Park Partnership:
An On -Site Water/Wastewater Permit, number S W030079, issued by this office for a single-family
system, will expire on April 13, 2004. This permit was valid for 365 calendar days.
If this was a well permit and the well has been drilled, a well log must be sent to this office for
documentation of the installation and to close the permit.
If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to
this office for review, approval and documentation. This as -built inspection report must be signed by
the licensed Professional Engineer who inspected the installation of the system. As -built inspection
reports are required to be submitted within 30 days of the completion of the system.
If no system was installed under this permit, and you are still planning to install a well or wastewater
disposal system, a new permit must be obtained from this office. A new permit for a second year may
be issued for a fee of $115.00 if the renewal application is received on or before the expiration date of
the original permit.
When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well
permit.
If you have any questions, please call this office at 343-7904.
S7es
,
aw
Joss, P.E.
Manager
On -Site Water and Wastewater Program
Enc: Copy of permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Permit Number: SW030079
"Legal Description: Right of Way Acquisition Tract B3
Design Engineer: 0060 DHI Engineering
Owner Name: Tuxedni Park Partnership
Owner Address: 800 E Dimond Suite 3-545
Anchorage . A 99515 -
Date Issued: Apr 14, 2003
Expiration Date: Apr 13, 2004
Parcel ID: 041-022-34
Site Address: 800 E Dimond
Lot Size: 43124 SO. FT.
Total Bedrooms: 0 Permit Bedrooms: 0
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
(5. -The following special provisions.' _
': THIS PERMIT EXPLICITLY FOR WELL WATER EXPLORATION. WHEN THE WELL HAS BEEN COMPLETED
'AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN
r APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE
y, INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED.
2 THIS PERMIT IS FOR TUXEDNI PARK BLOCK 3 TRACT B:
Received By:
Issued By:
Date: /W/,5/43
Date: U
Municipality of Anchorage
Development Services Department
Building Safety Division '
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.cl.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. ()cj!" Permit Number SWO30079
Propertyowner(ship Dayphone i44_1485
Mailing address (1 'I SAS
Mailing address (2) Anchorage Ax Zip Code 99c;15
Legal description (Lot, Block & Sub'd.) Tract B-3-Rightof Way Acquisition palt (82-239 )
Legal description (Section, Township & Range) NW 1 /4 , Sec 6, T12N R2W, S.M
Lot Size_0 4 a a cre Sq.Ft.
Number of Bedrooms
y,faLl
THIS APPLICATION IS FOR:
Sewer Only
❑
Well Only
IR
Sewer and Well
❑
Water Storage
❑
Sewer Upgrade
❑
THIS PROPERTY CONTAINS:
Hot Tub
❑
Jacuzzi
❑
Swimming Pool
❑
Water Softening Unit
❑
Therapy Pool
❑
that the above Information is correct. I further certify that this application is being made for a
'hrnily Dwelling apd is In accordance with applicable Municipal Codes.
(Signature of property
agent)
Permit Fees: ,nb /-`D Waiver Fees: _
Date of Payment: Ya -111 &_2 Date of Payment:
Receipt Number: =3b� Receipt Number:
(Rev. 12100)
00 DHI CONSULTING ENGINEERS
Civil Surveying Planning
Mr. Jim Cross April 11, 2003
Municipality of Anchorage W.O.: 02558
Dept. of Development Services
P.O. Box 196650
Anchorage, AK 99519-6650
RE: Tuxedni Park West
Domestic Well Locations
Dear Mr Cross,
Enclosed is a map showing the location of the three wells which we propose to construct and test for
purposes of meeting the "Aquifer Testing" as outlined by your Department. The wells as shown are at
the same locations as we discussed during our meeting on April 10m. We intend to drill the well on
Monday of next week in order to take advantage of the frost to support the drill rig.
As discussed, we will drill the well on Lot 5 (proposed) first. Based on the information we obtain during
the drilling of this well we will make adjustments to the depth to drill the next two wells. The object well
be to tap and test the shallow aquifer (80 to 150 feet), as this is the aquifer which most of the existing
wells (on adjacent lots) are currently using. Testing this aquifer should allow us to determine whether
there will be impact to near by wells.
Enclosed are the well applications for each well along with the $150.00 application fee (for each well).
If you have any questions concerning the enclosed information, please give me a call.
truly
Dee High,
Principal
mildh
e Iomm
cc: rim Mumer
Roger cmmo
55WtapA103 Mr
Dimond Center Tower, 5th Floor • 800 E. Dimond Blvd., Suite 3-545 • Anchorage, Alaska 99515
(907) 344.1385 • Fax 344-1383
ap
Z
0
LLI
0 'I'D