On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP121229
PID Number: 011-161-49 ❑ New ❑✓ Upgrade
Name:
Wolverton Living Trust
ABSORPTION FIELD
❑ Deep Trench 21 Shallow Trench El Bed ❑Mound
Address
8483 Sundi Drive Anchorage, AK 99502
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
1.2GPDISF
11.1 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
7.1 Ft.
Gravel depth beneath pipe
4.OFt.
Subdivision
Block Lot
Halls
2
Fill added above original grade
0-1 Ft,
Gravel length
40 Ft.
Township Range Section
Gravel width
S.OFt.
Beds: Number of Lines
Distance between lines
Ft
SEPARATION DISTANCES
T°
Septic
Absorption
Lift Station
; Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line400
Ft2
1
Ft.
Well
>150'
>150'
N/A
I N/A
125'
TANK +❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1 1,250Gal,
Surface water
>100'
>100'
N/A
j N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
I N/A
Steel
1 Two
1.11
NA
Foundation
>5'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
None
Noted
Remarks
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL Housetotank D3034 Tank to D3034
drainfield
Alaska General
Drainfield HDPE CO/MT D3034
Inspector MEA
BENCH MARK (Assumed elevation) 100.Oft
Inspection.�
dates: f 8/21/12 2na 8/22/12
Location and description
aro —
4tn
Back Lower Deck. Northwest Corner.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
`s�gays Sia `k►
P�••�•..•,., q ►
`
Conditional Approval:
Date
AV
* e
.•. .a •Y• .•.�
.• .•••1• • • I...I..d
dd r'a^ .AMQIAa E ANDERSON :1%
CE -4381
►��t'p
Approved__ /` Date /v2'/3�
®�5®m+®+41-f
ibpeuurni Repun_ , 1p <.uuc
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
I 4700 Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
Permit No.: OSP121229 I On -Site Wastewater Disposal System or Well Inspection Report
Page 2 of 3
PID No. 011-161-49
V,
F-------
49th
MICHAEL E. ANDERSON
WORKSHOP/ LOT 2 M1 1
17,916 S.F. C C4 I
I
------ -------------------------
10' T&E Easement
LOT 18
SITE PLAN
SCALE 1' = 30'
LEGEND
CO -
Cleanout
HALL
SUBDIVISION,
LOT
2
SV -
Septic Vent
FCO
- Foundation
A I B I C I D
$1 24.1' 14.4'
I
= 26.3' 22.1'
Class C
.
C2 35.3' 27.8'
Well
C3 37.0' 28.6
19.01
M1 7.6 62.3'
F
- -
C4 61.8'
L
O
iLO
LOT i
I
S 89°41 ' 10"E
1
1143.70'
L.
N.
GRAVEL '.
-
-
DRIVEWAY-..:.
/
S2
I
..
/ S1
..
O
-
/g
C2
o
- r7
_
-
FCO
C3
1
O
/
m
/
o
W
o
�/
m
.4
Z
Theor
I
Berdioom
Huse
N
�
I
I
i
I
I
Z I
TH1 I
I
D I
fffffi—fTfTTI i /
V,
F-------
49th
MICHAEL E. ANDERSON
WORKSHOP/ LOT 2 M1 1
17,916 S.F. C C4 I
I
------ -------------------------
10' T&E Easement
LOT 18
SITE PLAN
SCALE 1' = 30'
LEGEND
CO -
Cleanout
MT -
Monitor Tube
TH -
Test Hole
SV -
Septic Vent
FCO
- Foundation
Cleanout
—f
DO
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP121229
98.5
to W U U
1,250
Tank
U
PID No. 011-161-49
40' (Trench Length)
PR❑FILE AS -BUILT
No Scale
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121229
Tax Code Number: 01116149000
Work Type: Septic Upgrade
Permit Effective Dates: August 10, 2012 to August 10, 2013
Design Engineer: ANDERSON ENGINEERING
Subdivision: HALLS
Site Legal Address: HALLS LT 2 G:2324
Owner/Address: WOLVERTON LIVING TRUST
WOLVERTON H E & D L/TRUSTEES 8483 SUNDI DRIVE ANCHORAGE AK 995025168
Site Mailing Address: 8483 SUNDI ST, Anchorage Lot Size in Sq Ft: 17916
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
A —/D I 2
Date:
MUNICIPALITY OF
Community Development Department C*_
Development Services Division
On -Site Water & Wastewater Program
Parcell.D. 011-161-49
Mayor ®an Sullivan
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Property owner(s): Harold Wolverton Day phone:
Mailing address: 8483 Sundi Drive Anchorage, AK 99502
Site address:
Same
Legal description (Sub'd., Block & Lot): Halls, Lot 2
Legal description (Township, Range & Section)
Phone: 907-343-7904
Fax: 907-343-7997
Lot Size 17,916 Sq. Ft. Number of Bedrooms: Three (3)
THIS APPLICATION IS FOR: THIS APPLICATION IS AN:
(El all that apply) Initial ElAbsorption Field X
Septic Tank
Upgrade X
Holding Tank ❑
Renewal ❑
Privy ❑
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 536 . ca' Waiver Fees:
Date of Payment: 9/d/0 Date of Payment:
Receipt Number: (9q5_(),:3 -2 Receipt Number:
Permit No. 0SPI '�? ],-a Waiver No.
C:\Users\AndEng\Desktop\Mike\Sampson Estates\Permit Application Lot 2.docC:\Users\AndEng\Desktop\MikelSampson
EstateslPennit Application Lot 2.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
August 1, 2012
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 2, Halls Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 2, Halls Subdivision intends to upgrade the septic system on the lot.
We are therefore requesting a permit be issued for the construction of a septic system
to accommodate the home. The attached Site Plan and backup documentation identify
the location and configuration of the proposed septic system along with the Class C
Well currently serving the home. The sewage from the house is now disposed through
the septic system on the adjacent lot. No conflicts exist between the proposed septic
system and well or septic systems on adjacent lots. Drainage arrows are shown on the
site plan showing the grade and direction of flow on the lot. The drainage pattern will
not be changed as a result of this project.
A test hole was placed on the lot in the area of the absorption trench. The log indicates
silty sand (SW/SM) in the zone specified for the absorption trench. The percolation rate
of the soil was determined to be 3.2 minutes per inch. No groundwater was found
during the placement of the test hole and none was noted during the monitoring period.
An application rate of 1.2 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,000 -gallon septic tank and a 40'
long by 5' wide by 4' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 9' below the surface and the total depth will be 13'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the
septic tank.
The ground surface on the lot in the area of the septic system slopes to the north at a
shallow grade. The slope becomes steeper with distance from the north property line.
The new trench will be constructed parallel with the contours of the slope as much as
Lot 2, Halls Subdivision
August 1, 2012
Page Two
possible in conformance with Municipal requirements. The new septic system will be
constructed a minimum of 150' from the Class C Well and 100' from any surface water
and 10' the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
49th
MICHAEL E. ANDERSON
Class C
Well
0
.V3: 49th
I \\
HALL SUBDIVISION,\ LOT 2
I '
NOTE',
No Conflicts with Wells or
Septic Systems on o
Surrounding Lots. X11
I '
Existing Sewer
Service Currently
Utilizes Septic
System on Lot 1.
LOT 1
S 89°41'10"
MICHAEL E. ANDERSON
I '
I
Cleanout
1 I 143.70'
Monitor Tube
TH —
Test Hole
jAbandon
Septic Vent
Existing
— Foundation
Service Line.
2% _
I
1,000 Gallon
I
Sepfic Tank
I
SV SV 2C0
I0
I
M
I
I o
I m
1 m
I
CO
I
I
I
1
TH1
I
I
I
I
9
I
I
I
/ 2%
I I
WORKSHOLOT 2 '
PS MT ! I
17,916 S.F. �
Co 1
------ ------------------------J
10' T&E Easement
NOTE
No Slopes >25% Within 50'
of Absorption Trench. No
Surface Water Within 100'.
LOT 18
SITE PLAN
SCALE I' = 30'
40' Long x 5' Wide
x4' Effective Depth
Absorption Trench
q:01:1►11f
CO —
Cleanout
MT —
Monitor Tube
TH —
Test Hole
SV —
Septic Vent
FCO
— Foundation
Cleanout
LOT 2, HALLS SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS
Three Bedroom Home 5' Wide Trench System
Perc. Rate: 1-5 Min./Inch 1,000 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
3 Bedrooms * 150 GPD/Bedroom = 450 SF Absor tion Area
450 SF/1.2 GPD/SF/5 SF (Width) *.5 (Red. Factor 37.5 LF Trench Length
THEREFORE: Construct a 40' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 9' Below Original Ground Surface. Total Depth to be
13' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank. Septic Tank Burial Depth a Minimum of 7'.
TYPICAL 5' WIDE TRENCH SECTION ••o����p�i
•.• E
(NO SCALE) ••,�p'(.............•••`..;�
NOTE: Grade Area Over Trench to Drain Away. Cts::
Minimum 6' Separation From Bedrock. .;,,�,,.,;4,9,th,,,g
Minimum 4' Separation From Groundwater. i
r..............
Minimum 100' Separation From Private Wells in the Area. �A: MICHAEL E. AND mZS
Minimum 100' Separation From Surface Water or Streams: �j %.% No. CE4381
E13
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
DEPTH
(feet)
1-
2
3
4
5-
6-
7-
8-
9-
10-
1I
12
13
14
15
16
17
1
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 2, HALLS
PERFORMED FOR: HAROLD WOLVERTON
DATE: 7/6/2012 PROJECT No.: _
PARCEL ID#: TECHNICIAN: _
TEST HOLE 1
HUM OG/OL
Sand with Silt
SW/Sm
Dry
:o■
MEA
SLOPE
N
WAS GROUND WATER ENCOUNTERED?
No
IF YES rQi WH
DEPTH OF WATER AFTER MO
DATE OF MO
AT DEPTH?
NITORING Mone O 2%
N[TORING: 7/31 p
CF GROSS TIMEJ NET TIME DEPTH TO NET DROP
DATE READING (MINUTES) (MINUTES) WATER (INCHES)
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
7/6 1 1:10/1:20 10 2.25"/5.50" 3.25"
2 1:21/1:31 10 2.00"/5.13" 3.13"
3 1:32/1:42 10 2.25°/5.38" 3.13"
4 1:43/1:53 10 2.13"/5.25,, 3.12"
5 1:54/2:04 10 2.00^/5.13^ 3.13"
6 2:05/2:15 10 2.13"/5.25" 3.12"
PERCOLATION RATE:: 32 (MINAINCH) PERC. HOLE DIA. 9 (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 7/31/2012
PERCOLATION RATE:: 32 (MINAINCH) PERC. HOLE DIA. 9 (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 7/31/2012
AI4IJS
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On-Site Systems Approval
Parcel I.D. 011-161-49 Expiration Date: S
1. GENERAL INFORMATION
Complete legal description HALLS LOT 2
Location (site address) 8483 SUNDI STREET,ANCHORAGE,AK 99502
Current property owner(s) JAMES&CYNTHIA RUTH Day phone
Mailing address 400 W 76TH AVE.APT. 101,ANCHORAGE,AK 99518
Real estate agent Day phone
2. TYPE OF DWELLING:
P Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Private Well ® Private Septic
Water Storage ❑ Holding Tank ❑
Community Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 55D Waiver Fee $
Date of Payment qi (41f q' Date of Payment
Receipt Number O1ci333/) Receipt Number
COSA# 10500!/2 C.. Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted.
Name of Firm ANDERSON CONSTRUCTION &ENGINEERING Phone 345-3377
Address 4640 SHOSHONI DRIVE,ANCHORAGE,AK 99516
Engineer's Printed Name MICHAEL N.ANDERSON,PE Date 4/22/2019
OF \
sI
*49 � • * v
6. DSD SIGNATURE
System #1 Approved for 3 bedrooms MICHAEL N. ANDERSON. he
No. CE 9489 w /
System #2 Approved for bedrooms 11 4/22/19/
Disapproved \ Ssiolo' .i
Conditional approval for bedrooms, with the following stipulations:
toll((((((
OF ug,
f'(
404,
ON-SITE
WATER " �
STEWATERAND '
bz
PGRAM
WARO ,
",?1/4
)>>>S)11111��\�`\
By: Original Certificate Date: —
—I
The Municipality of Anchorage Development Services Division (DSD)issues Certificates of On-Site Systems Approval (COSA)based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
COSA Checklist
Legal Description: HALLS LOT 2 Parcel ID: 011-161-49
If more than 1 septic system on lot: COSA Checklist# of Structure served by this system
A. WELL DATA— PRIVATE CLASS C
Well log is filed with Onsite (or attached) Well production at time of test gpm
Dat- •rifled Water storage tank volume gallons
Total de• ft Well disinfected for coliform test? ❑ Yes ® No
Cased to • ® Coliform bacteria is Negative
❑ Sanitary seal is f •ctioning correctly Nitrate ND mg/L ® Nitrate less than MRL (ND)
❑ Wires are properly pro -cted Arsenic 59.5 ug/L ❑ Arsenic less than MRL (ND)
Casing height (above ground) in. Collected by FWCS
Date of flow test for COSA Date of Sample 3/4/2019
Static water level at beginning of test ft.
Comments
B. TANK DATA—8/22/12 - 1250-gal C. LIFT STATION - NA
Age of tank(s) 6.5 years ❑ Required maintenance completed
Tank type/material STEEL Age of lift station years
Measured operating fluid level in septic tank 50.5" Lift station material
® Standpipes/foundation cleanout per record drawing Comments:
Date of pumping 10/1/2018
D. ABSORPTION FIELD DATA—40'L x 5'W x 4'ED— 1.2 GPD/SF = 400 SF
Which system tested (date installed) 8/22/2012 Adequacy test date 3/5/2019
® ALL standpipes present per record drawing Results El Pass For 3 bedrooms
Total measured depth from grade 11.5 ft (max) Fluid depth prior to test 0 in
Measured depth to pipe invert from grade 7.5 ft(min) Water added 700 gal
❑ N/A— pressurized field New depth 0 in
® Monitor tubes go to bottom of effective. If not, state Elapsed time <1 min
depth into effective
® Code-required soil cover over field Final fluid depth 0 in
® System presoaked Absorption rate 450+ gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N
date of test)
Gallons introduced 1700 gallons If yes, enter date
Comments/Deficiencies:
COSA Checklist copy.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)CLASS C WELL ADJ. LOT
Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout> !:
® Yes if No ft i es if No ft
Neighboring Tank > 100' ® Yes if No ft Private S- , - eptic Line > 25' ® Yes if No ft
Absorption Field on Lot > 100' ® Yes if No Holding Tank > 100' ® Yes if No ft
Neighboring Absorption Fields > 1 Animal Containment > 50' Z Yes if No ft
Yes if No ft
Manure/Animal Excreta Storage > 100'
Corr it1Sewer Main > 75' Z Yes if No ft ® Yes if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ® Yes if No ft Wells on Adjacent Lots:
Property Line > 5' ® Yes if No ft Private Wells > 100' ® Yes if No ft
Absorption Field > 5' ® Yes if No ft
Water Main > 10' ® Yes if No ft
Community Wells > 200' ® Yes if No ft
Water Service Line > 10' ® Yes if No ft
If septic tank is under driveway comment below
Surface Water> 100' ® Yes if No ft
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below
Property Line > 10' ® Yes if No ft Wells on Adjacent Lots:
Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No _ft
Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No ft
Surface Water> 100' ® Yes if No ft
F. ENGINEER'S COMMENTS
A OF AL
G. ENGINEER'S CERTIFICATION .
A.'. 1 ...ter' 1
I certify that I have determined through field inspections and review /:•'4 9 TH 1\ *
of Municipal records that the above systems are in conformance /
with MOA COSA guidelines in effect on this date. I 4
r
MICHAEL N. ANDERSON:
1 i No. CE 9489 .•4'w....SAO COSA Checklist copy.docx 4.22,:19 �'
0,z;
0FRsslO0' AV
1 I 8480T
25 I I
Lot 1
I
S89°41'10"E 143.70
1
t
N
1— 0 0 28.0 Lot 2
WE N Septic vent(typ)
WW t Gravel driveway N
0
I— W 5.2 0
_.. 8.3 ° °
O W deck tri
ti °
o Q �s 17.0 0 ° !i!H Lot 10
z to I--
p 18.5 ..
I
m W
i• 4 2 Story Frame house E L
Cf..'
O Window welt with Basement co CQ
ce) deck W fV
CO o O
0 W0
O 47.: 13.0 z
I A0 0,5o
37.0 =
00
L • J
25 10'T& E Easement NI
f ,
S89°41'10"E 142.96 _ __
Lot 17
Lot 18
`�\\�\ ` AS-BUILT NO CORNERS SET THIS DATE
�� OF •• %• I hereby certify that I have performed a Mortgagee's Inspection
. •
'QS' , of the following described property: LOT 2.
�~• 4�9 th 1� '•�"9 ,e HALLS SUBDIVISION
i�
L iiiigi• •�'�,.���' •• 11 . % Anchorage Recording Precinct,Alaska,and that the
0,4 �ieF Improvements situated thereon are within the property fines
I .Elizabeth L Walntka: / and do not overlap or encroach on the property lying
adjacent thereto,that no improvements on the
/ • 8°36 - LS •/� erty lying
adjacent thereto encroach on the premises In question and
1 "0 9•�.,� •• 4 that there are no roadways.transmission lines or other
'Ess• • • .�" A visible easements on said property except as Indicated
SCALE: 1"= 30' t r\\��� hereon.ct Anchorage,Alaska
EASEMENTS OF RECORD,OTHER THAN 2_ this 8th day of February ,2019.
THOSE SHOWN ON THE RECORDED z1
PLAT ARE NOT SHOWN HEREON FRED WALATKA&ASSOCIATES.L.L.C.
UNLESS OTHERWISE NOTED. RPH, FB 19-2,pg 9 BE gp7_z48-16136 Engineers and Surveyors