Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
HERITAGE HILLS BLK 5 LT 6
Heritage Hills Block 5 Lot 6 #015-221-34 Inspection Report _1-1-1 o Municipality of Anchorage Community Development Department Page ( of On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: DSIP ( 21 0 Sf PID Number: O(g:� – 2 2 t –3V [' ''New ❑ Upgrade Name: N( TJ r 4- yr c ABSORPTION FIELD [d Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade ,�1 l ti � GPD/SF /D Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade f . 0 Ft. Gravel depth beneath pipe d. & Ft. Subdivision Block Lot AF P f t th AC S iA Fill added above original grade / 0 " Ft. Z Gravel –7 length) r9�j Ft. Township Range Section Gravel widthBeds: Z• U Ft. Number of Lines Distance between lines I Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft. well r� iUbl j/ /� k Shc� TANK Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacture f_ l v re* 1_N✓ Capacity Gal. Surface Water tF /r!U/.� /Ua Material 5 .�_ Number of compartments Z - Lot Line z J I{ r NA Foundation ZJI LIFT STATION Manufacturer Capacity Gal. Curtain Drain 1.414 Remarks Pump on level at Pump off I at High water alarm at (Al bcr..tr 11Yc�i n. in. in. Pump make model Electrical Inspections performed by Installer PIPE MATERIAL House to tankP 3o Tankto 3 � �i drainfleld 9 / •/� MP4__r.�rlie✓y.1 • Drainfeld 3P314 CO/MT 703W Inspector—i -, . kms N te.41 1 01 BENCH MARK (Assumed elevation) /,uo ft Inspection%&,t*S Iq Location and description G,PII Cr �, dates: 3 2 I•� P 0 COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp `tea®®a\p9 .o g� 0 �Ca®pt Conditional Approval: Date J it •A •• MICHAEL N. ANDERSON •. '1 00 r`o.�j �,` Approved rZ Date_ w�r 4�®�rnFSd" Inspection Report _1-1-1 o Permit No. OSP121051 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: HERITAGE HILLS BLK 5 LOT 6 PID No.: 015-221-34 —=r-----�=— I C�6MT= _= _,jC05 CO3 1 TCO // BENCH, TOP OF WOOD DECK \ TCO1 CO2 \\ L ----Z CO B 1 I I I I I I 1 MARK A B GRND. ELEV. PIP ELE FCO 8 37 99 95 c01 49 99 94 CO2 1 55 99 94 Tc01 38 60 99 TCO2 46 67 98 CO3 50 70 97 93.6 C 52 71 97 93.6 MT57 75 97 C05 44 55 96 92 Cos 70 95 95 92 EXISTING HOUSE 100' EXISTING WELL i ASBUILT SCALE: 1"=30' .. ...F �.... i 49TH i ♦. ... ........................ . a ........................... MICHAEL N. AND ♦�G/s N/V_E 469 \ i SEPTIC SECTION N.T.S. FROM :Alpine Drilling FAX N0. :907 345 0202 Apr.20 2012 06:20PM P1 Alpine Drilling & Enterprises Well Log Permit Number: #SW1 1 1 Date of Issue: 4-18,1 Parcel Identinc tion Number; 01522 -IM location? x Yes No Date Started: 4-18-12 Date Completed: 4-19-1 Is well located at approvedpermit Legal Description: Heritage Hills Block 6 Lot 6 Property Owner Name & Address: A d son MNatrwAve N 50% and Schutt Dale T50% Borehole Data: Depth (ft) Soil Type, Thickness & Wsw Strata From To slick -Up 0 2 sift 2 14 gravelly sift 14 31 silt 31 36 graven( $91 36 51 sandysilt 51 65 silt 65 91 silty gravel 91 94 gravelly silt 94 125 out 125 145 gravelly silt 145 230 silty water sand & gravel 230 234 Method of Drilling x air rotary ❑ cable tool Casing type: s"l Wall Thickness: 250 inches Diameter: 6 inches Depth: 234 feet Liner Type: Diameter: T inches Depth: _ feet 2nig stickep above grounds 2 feet Static water level (from ground level): 17Qfeet Pumping level:79_feat after 2 hours pumping 15 gpm Recovery Rate: 15 gpm Method of Testing: a' ti Well Intake Opening Type: x Open End ❑ Open Hole ❑ Screened Start _ feet Stopped — _fed ❑ Perforations Start _ fest Stopped feet Grout Type: Benton' Volume: Zhu Start 0 fbet5fed Pump: Intake Depth _ fact Pump size _ lip Brand Name Well Disinfected Upon Completion? x Yes © No Method of Disinfection: chlorine tablets Comments: Wen Driller. Alpine Drilling & Enterprises PO Box 110496 Anchorage AKAlaska Development Services Department Building Safety Division ,e ° 8 On -Site Water & Wastewater Program ` 4700 Elmore Road P.O. Box 196650 Mark Begich Anchorage, AK 99507 s n c r r Mayor www.murd_org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW Date of Issue: _ Parcel Identification Number: Legal Description Property Owner Name & Address: f 5f Y<LN c� of /arc 0 ff5 ec Pump Installation Date: Pump Intake Depth Below Top of Well Casing: -216, feet Pump Manufacturer's Name: Gl cam/ rii j Pump Model: "(7,; 5 q 5 fS 33" Pump Size i hp Pitless Adapter Burial Depth: I < feet Pitless Adapter Manufacturer's Name: C�_- •MPS .- // Pidess Adapter Installer: c✓l /<- Well C Well Disinfected Upon Completion?df Yes ❑ No Method of Disinfection: I Comments: /,3--/� h Pump Installer Name: Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Michael N. Anderson, P.E. Civil/Structural Engineering & Construction 4661 Natrona Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 July 18, 2012 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 II( N'�:R4e 1Yi 1.15 Re: 4 �BJkLZWk.J_ To Whom it may concern: This is an application for a lot line waiver of 3 feet on the above referenced lot. Justification for the waiver is the lot is small and doesn't have much room for the original and the secondary without encroaching on the west property line. The neighboring lot is owned by myself and will not object to this waiver. Approval of this lot line waiver will not impact any of the neighboring properties. If you have any question please call me at 727-8864. Sincerely ��� Michael N.'Anderson, P.E. Attachments: None Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907)343-7904 • Fax(907)343-7997 http://www.muni.or-q/Onsite Development Services Division On -Site Water and Wastewater Program mens Department **** VARIANCE/WAIVER REVIEW **** Waiver#: osp121052 COSA#: osc121407 Permit#: osP121051 PID#: 015-221-34 Legal Description: Heritage Hills B-5 L-6 Engineer: Mike N. Anderson Applicant: Merrit Homes Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 8.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: Q _ ' Approved by: of viewer ........................................ .... .. .. viewe.................. Rec#: 151742 Amount: $200.00 Date Paid: 4116112 **** VARIANCE/WAIVER REVIEW **** On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121051 Tax Code Number: 01522134000 Work Type: WellSeptic Initial Permit Effective Dates: April 18, 2012 to April 18, 2013 Design Engineer: ANDERSON CONSTRUCTION & ENG'G Subdivision: HERITAGE HILLS Site Legal Address: HERITAGE HILLS BILK 5 LT 6 G:2737 Owner/Address: ANDERSON MICHAEL N 50% & SCHUTT DALE T 50% 4661 NATRONA AVE ANCHORAGE AK 995160000 Site Mailing Address: Lot Size in Sq Ft: 20400 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Receivi Issued MUNICIPALITY OF F ANCHORAGE Community Development Department) Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. OI 5— Z2t -34 Property owner(s) Ch r, s Pr ✓ ro sv.o Avfr++r 1t /yan r S Day phone Mailing address Site address Legal description (Sub'd., Block & Lot) gra,-gea y(,//S (�, S L Co Legal description (Township, Range & Section) Lot Size 7-5 L40 Z) Sq. Ft. THIS APPLICATION IS FOR: (® all that apply) Absorption Field 9 Septic Tank Holding Tank ❑ Privy ❑ Private Well 15� Water Storage ❑ Number of Bedrooms If THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. re of property owner or authorized agent) Permit/Rush Fees: S3r7 f 200 IC Z 0 V Waiver Fees: $'266 - Date of Payment: r / z— Date of Payment: WM2 Receipt Number: /5Receipt Number: / n/5 / 3qa Permit No. Gspi� 105 1 Waiver No. W P1'g1o9' G ABuilding\On SiteTorms\Client FormsTermit App _010411.doc (Rev. 1/11) Michael N. Anderson, P.E. Civil/Structural Engineering & Construction 4661 Natrona Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 April 12, 2012 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: Heritage Hills Subd. Blk 5, Lot 6 To Whom it may concern This is a request for a new 4 bedroom septic system and well permit. A test hole was excavated at the northwest corner and found silty -sandy gravels, SM/GM for the entire 18 foot depth. No water was observed during the excavation or after the 7 day monitoring period. The perc rate was measured at 10 minutes per inch. -As ran be Y K b / AA. �� Please b@ R__.� ,I�� .,. a ,. a i« 4 p. sBe .... . .......... _ ooa te-uctify�}one. The new •.II NN i system will consist of a 47 foot deep trench for both the primary and secondary system, see the site plan. Several surrounding lots are vacant, but they will not be impacted by this new 4 bedroom system. The slope is flat as you enter the lot, then gradually slopes down about 10 percent to the northwest with no cut banks or open water with 200 feet. Please call me if you have any questions. Sine I Michael N. Anderson, P.E. O 20' STORM DRAIN EST. SECONDARY TRENCH 10' T&E EST. 10' OFFSET �\ 10' T&E EST, ------ ---- — 10' r —------------- i PROPERTY LINE r PROPERTY I UNE I ,co MT OFF—SET TO o 11 �� ----- --------- CO i BE FLAGGED afl t` i BYt` CO Go _ TCO PRIOR O PROPOSED �t� TOO DRAINFIELD `tom coNsr. co �/ C0 PROPOSED 4 �� 1 PROPOSED 1250 % BEDROOM GALLON SEPTIC HOUSE TANK �o I I ` I PROPOS WELL \ \ I DE�OMISSIONED FIELD I I I WELL RADIUS TO BACKFILLING FLAGGED 13Y..AROUND THE NEW SURVEYOR, PRIOR WELL CASING SHALL I I TO SEPTIC CONST. �� BE MOUNDED TO NT ANY PON THE FUTURE. VACANT LOT Septic Design Prepared for CHRIS PETERSON-MERRIT HOMES HERITAGE HILLS SUBD. BLK 5, LOT 6 Anchorage, Alaska Michael N. Anderson; P.E. DATE: 4661 NATRONA AVE. DRAWN: ANCHORAGE, ALASKA 99516 PH 345-3377 / FAX: 345-1391 I SCALE 4/12/2012 DJR 1"=30' bESIGN CRITERIA: 4 BDRM X 150 = 600 GPD SOILS = 600/0.8 = 750 GPD 750 GPD/16 = 47' (1) TRENCH 10.0' DEEP 8.0' EFFECTIVE 2.0' WIDE 47' LONG I \ / , , � c ?SEPTIC 1 I PROPOSED- \ DRAINFIELD \-rr------- L— — — — — — — IF— — — — — — 5 VACANT PROPOSED WELL 100' RADIUS, TYP— VACANT 3 MOUND OVER (TH#1) ot;E GRADE 0.5 ORG FlLTER FABRIC -10.0-L SEWER ROCK 2.0' 1 18 " BOTTOM OF HOLE 1SEPTIC � VACANTVACANT -PROPERTY LIN ELL 1 /SEPTIC LJ 5 Septic Design Prepared for CHRIS PETERSON-MERRIT HOMES HERITAGE HILLS SUBD. BLK 5, LOT 6 Anchorage, Alaska Michael N. Anderson, P.E. DATE: 4661 NATRONA AVE. DRAWN: ANCHORAGE, ALASKA 99516 PH 345-3377 / FAX: 345-1391 SCALE: 4/12/2012 DJR 1"=100' �'• 49 T 1AEL N. No. CE H N *7 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci. anchoraae.ak. us (907) 343-7904 Solis Log - Percolation Test OF •yep,• •�t.�y�� a9TH Performed For: Rd/ /q�r��e d Ir Jne r Date Performed: Legal Description: //.rrl 4qg e. //IS f/�' s/ L (m Township, Range, Section: — I (Feet)—`i, Or'3 ante S 1- 2- L004C/r rat 3- ((( N 4- COMMENTS U4 S'G MICHAEL N. ANDERSON ."e 94 9 FDn •..et Site Plan Reading Date WAS GROUND WATER 9- Depth to Water ENCOUNTERED? Q S 10- IF YES, AT WHAT DEPTH? L Depth to Water Atter D P 11- Monitoring? � h ei e 12- Date: 4 / 13- COMMENTS U4 S'G MICHAEL N. ANDERSON ."e 94 9 FDn •..et Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop rr L " 3// 71/ �., 3/1 PERCOLATION RATE /V (mi.W.A ch) PERC HOLE DIAMETER (Q TEST RUN BIETWEEN �FT AND FT !u Hxr.yF //1� i/ PERFORMED BY: J-1 "r-la.4 & Prb r"l I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Municipality of Anchorage Development Services Department Building Safety Division a On -Site Water and Wastewater Program 5. et. 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 ws wwwde 07) 343rg/ 04 <' ' �► CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. Df '- 22 ► - 3 LI COSAa 0t;C.1Wgo1 Expiration Date: �n - 1. GENERAL INFORMATION, Complete legal description H TJ , i d a c IJt s 5 o Location (site address) S_Q l l 1✓ 131 Sr 1�/e .Current. Property owner(s) M r r r. 4v m < <. Day phone Mailing address - Lending agency Day phone Mailing address: Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA m7l be held by DSD for pickup. i 2. NUMBER OF BEDROOMS: K , 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [ Individual On-site I Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ . Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent. professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and.may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are. valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my -Investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply'and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from myinvestigation and inspection, the on -"site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm M+ Jit AJi d evsuA Phone 2 7 — V96 4 Address t-4 (0 i/ f /�A (A'-fo r CL A Engineer's Printed Name I�?„ Na[ U11 d tfa on Date i OF.•�4( *: 4NO ✓.....,..rr%.. . j ,. /•f(✓.ssi r. If. ..... s.• MICHAEL N. ANDERSON 5. 'DSD SIG ATURE �f+ J �, CE 99 V Approved for �'r bedrooms. /.'• •Z�`��� Disapproved; Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other By; ' o Original Certificate Date: I — 6 - /—?— Municipality of Anchorage • ' ° Development Services Department Building Safety Division ° On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Af L -u Parcel ID: U t S — ZZ I — 3L( A. WELL DATA Well type P<t°'* �G if A, B, or C provide PWSID # Well Log (Y/N) Date completed ���/ %� Sanitary seal (Y/N) Wires properly protected (YM) _ Total depth 2`�i ft. Cased to Casing height (above ground) n.i FRO WE L LOG AT INSPECTION Date of test ( 'L Static water level ft. _e ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: ,} Coliformtcolonles/100 mL Nitrate Q, (0 1 mg/L Collected by: ?i 14 cAr e✓4w Arsenic:ugL date of sample:—L-2', Z B. SEPTIC/HOLDING TANK DATA Tank Type/Material e7 ati ` Date installed Tank size 17-5 gal. Number of Compartments Z- Cleanouts (YIN) Foundation cleanout.,(Y/N) Depression over tank (Y/N) High water alarm (YM) Date of pumping tt rtA7 Pumper C. ABSORPTION FIELD DATA Date installed A_1Z Soil rating (g.p.d./ft2 or fe/bdrm) At� System type 0 rr Length _� ft. Width 7.0 ft. Gravel below pipe P ft. Total depth f ft. Eff. absorption area jZ Monitoring tube Y Depression over field Date of adequacy test / Results (Pass/Fail) For _�_ bedrooms Fluid depth in absorption field before test in. Water addedgal. New depthin. Elapsed Time: Amin. Final fluid depth,-' in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed "Pump on" level at —in. Datum Size in gallons e/Access (YM) �ufn level at —in. High water alarm level at in. Cycles tested Meets alar & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 10a On adjacent lots b 0 ' Absorption field on lot 0 0 r 4- On adjacent lots /0 0 r 4 - Public sewer main Public sewer manhole/cleanout 141 r Sewer /septic service line 60 4- Holding tank Animal containment areas /00' Manure/animal excrete storage areas I a0 SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: S r Building foundation /d, f Property line Zt) Absorption field Water main P A. Water service tine 100 f- Surface water t O 0 �� Wells on adjacent lots 10b t4 - SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: � t Propertyline t i alvRf Building foundation ZJ '- Water main % • Water Service line t o d t 4- Surface water 10 d t Driveway, parking/vehide storage Curtain drain Nt Wells on adjacent tots /udl L F COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's.Printed Name N1 tz6Vred'161 d "r 00 Date L Z 1 ` COSA Fee $ & S Date of Payment Receipt Number (Rev. 4110) 0 ©scialgcri Waiver Fee $ _ Date of Payment Receipt Number 4,9 .. ..... .......p io io P MICHAERSON ; �'' C 99 `� S 89 59' E 160.00 EAST 131 st __- A VENUE OF i a 4 9P QUO oePe. LS -691 a_ HOLT�oO A -BUILT SURVEY 1" =30' 4�D�n�FE6510N°�' p� FINAL STHUCIURE AS-BU/LT GRID 2737 I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 6, BLOCK 5, HERITAGE HILLS THEINFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS 5PECIFICALLY TO 5HOW ANY ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS: ANDIS VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN NOT TO REUSED FOR POSITIONING ADDITIONAL STRUCTURES,IMPROVEMENTS, OR FENCELINES. THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT, ARE NOT SHOWN EXIST OTHER THAN NOTED. HEREON( UNLESS INDICATED) DATED AT ANCHORAGE,ALASKA THIS _4TH_ DAY OF NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE _SEPTEMBER , 2012. PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. HOLT LAND SURVEYING ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. 600 HIGHVIEW DRIVE 11682, FS 151-10 ANCHORAGE,AK 99515 395-5513