Loading...
HomeMy WebLinkAboutPTARMIGAN ROOST BLK 2 LT 2Ptarmigan Roost Block 2 Lot 2 #020-042-70 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ONSITE WASTEWATER INSPECTION REPORT Permit Number: OSP121294 PID Number: 020-042-70 ❑✓ New ❑ Upgrade Name: Northwood Homes ABSORPTION FIELD ❑ Deep Trench ❑✓ Shallow Trench ❑ Bed ❑ Mound Address P.O. Box 92301 Anchorage, AK 99509 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2GPD/SF 5Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2 Ft. Gravel depth beneath pipe 3-OFt. Subdivision Block Lot Ptarmigan Roost 2 2 Fill added above original grade 1.5-2 Ft, Gravel length 50 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trendies From Tank Field Lift Station Tank Line 431 Fe One Ft Well >100' >100' N/A N/A >25' TANK ❑ Septic ED S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank/Orenco Capacity 1,250Gal. Surface Water >100' >100' N/A N/A Material Steel Number of compartments Three Lot Line >5' 2'** N/A N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Anchorage Tank/Orenco Capacity 250 Gal. Curtain Drain None Noted Pump on level at Pump off level at High water alarm at Remarks **See Lot Line Waiver. 42 in. 42 in. 44 in. Pump make and model Electricalspactions performed by I Ir PIPEMATERIAL Housetotank D3034 Tankto D3034 drainfield Installer Sanders and Sanders Drainfield F810 ComnT D3034 Inspector A. Harala BENCHMARK (Assumed elevation) 100.Oft Inspection 16� 1/17/13 1/18/13 Location and description dates: 2" Garage Slab. 3' 4,h COMMUNITY DEVELOPMENT DEPARTMENT �••�� P� Date 2✓ "a a-13 •�P��'•gS�14 ii[�: '•,�� Conditional Approval: Lt/ �?P ✓ Iih49 TH • * e �� ........ �M. Nb.........o•o....4M I+prYatn� E A ego ♦,� :�CE -4381 ,: \�`�r �'e- (y v �L 3 — Z �! ' 13 Approve Date��t»�� Fo Inspection RepWI-1-12.doc Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 Permit Number: OSP121294 iR 30' PLAT NO. 71-214 PTARMIGAN ROOST LOT 2, BLOCK 2 47,036 S.F. N 8926'30"E 223.98'(R) S 89'56'20"E 224.04'(M) 10' UTIL ESMT. Page 2 of 3 PID NO.: 020-042-70 t El ANDERSON Three Bedroom Home J 1 aP C / Alternate Site 1H3 Ni f N 89'58'30'E 224.09'(M) ALTERNATE SITE: N 8926'30"E 223.98'(R) Advantex Treatment System with 30' Long x 5' Wide x 3' Effective Depth Absorption Trench. 2 GPD/SF Application Rate. PLAN AS -BUILT SCALE 1' = 40' 1xHa.lW MT — Monitor Tube FCO — Foundation Clean Out TH — Teat Hole CO — Clean Out MH — Man Hole A I B C \ 51 18.4' 25.2' \ 52 12.0' 30.9' MH 1 11.8'133.0' \ M1 1102AYI 1109.3' \ e 1 t El ANDERSON Three Bedroom Home J 1 aP C / Alternate Site 1H3 Ni f N 89'58'30'E 224.09'(M) ALTERNATE SITE: N 8926'30"E 223.98'(R) Advantex Treatment System with 30' Long x 5' Wide x 3' Effective Depth Absorption Trench. 2 GPD/SF Application Rate. PLAN AS -BUILT SCALE 1' = 40' 1xHa.lW MT — Monitor Tube FCO — Foundation Clean Out TH — Teat Hole CO — Clean Out MH — Man Hole Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP121294 PID No. 020-042-70 102.1 30 - 5116" Diameter Holes @ 1.25' U U) 1250 Gallon STEP Tank 119.2 Drainfield Rock 1 117.5 102.5 Groundwater@ 107.5' 10-12-12 7 12.5 PROFILE AS -BUILT _ICHAEL- NO.E. CEA438RSON No Scale 115.5 INSPECTION REPORT MUNICIPALITY OF ANCHORAGE, BUILDING SAFTY DIVISION 4700 ELMORE ROAD INSPECTION INFORMATION and HELP: (907) 343-8211 INSPECTION REQUEST: VOICE (907)343-8300 FAX (907) 249-7777 ,wrcf< f'%e-tui'r sNS?F-r--r13 -1 l9�- ;LOO -7, ONLINE: www.muni.org/BSD/inspections.cfm �� -7 1 -7 NAME: AA D `f /Jim. PERMIT #: F -I 9. - 18 l � COMPANY: TDE F-mD AC3L.�, (ZV; e f -S INSPECT DATE: PHONE: 26ig - r4(o90 PHONE: 630-<:)7(g'7 PHONE: ADDRESS: db301 L.uokJa vf.? LOT: BLOCK: a SUBDIVISION: C�AAI Rom�s-r GRID#: 3g 36 COMMENTS or DIRECTIONS: TYPE OF INSPECTION: Ez,6r-.7-W REINSPECTION: YES NO COMMENTS: (FOR INSPECTORS USE ONLY) PRINTED NAME: /'�/' DATE: 10 — c'-4/ - o/3' ve.naaaaaa.exuUgB IY Ulaver: ULUU4L I VUUU Date Started: 11=$-12 Bate 'Completed:Y 11-10-12 is well locatedat approved permit location? x Yes Ej ,No Legal Description: Ptarmigan Roost Blk 2 Lot 2 Property Owner Name & Address: Gunther J 1972, Stephan Helene 2008 CharRem Unitst% David J 238 Cambridge, Ma Borehole Data. Depth (ft) Method of Drillin x air rota Soil Type, Thickness & W`ater Strata. Prom To g rY ❑ 7toolCasing type:steelStick-up 0 2 WallThicim ss:.250 inchesOrganics & silt 2 13 Diameter: 6 inches Depth: 43.5 febedrock 13 286 Liner Type:Diameter: inches Depth: Casing stickup above ground; 2 feet H2O 250 Static water level from ground level): 9 feet 260 Pumping level.' -18 -0 -feet after 10 hours pumping 2_5 gpm Recovery Rate: 2_5 gpm Method of Testing: aik t Well Intake Opening Type: Ej Open find xOpen Hole ❑ Screened Start—feet Stopped —feet ❑ Perforations Start _ feet Stopped _ feet Grout Type: bentonite chins Volume: S bes Pump:IntakeDepth_ feet Pump size _ hp Brand Name Well Disinfected Upon Completion? x Yes ❑ No Method of Disinfection: chlorine talidets Comments: &Nell Driller: Alpine, Driihng & Enterprisas POBox 110496 Anchorage AK 99511 On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121294 Tax Code Number: 02004270000 Work Type: WellSeptic Initial Permit Effective Dates: September 21, 2012 to September 21, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: PTARMIGAN ROOST Site Legal Address: PTARMIGAN ROOST BLK 2 LT 2 G3238 Owner/Address: GUNTHER J (1972),STEPHANI & HELENE (2008) CHAR REM UNITST % DAVID J 238 MAIN ST CAMBRIDGE MA 021421016 Site Mailing Address: 16301 LUNA ST, Anchorage Lot Size in Sq Ft: 47036 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.B.3 12/Z 51 Z co -X l C61c.' 'fl- G1 p'h� f' �Gi %o cafii'on nGl n-ra Ke 5 'Brun dee I% Wai'Vcrg I651ne�. Received Issued By: 9-Z-3-1z— Date: Z / / Municipality of Anchorage Development Services Division On -Site Water and Wastewater Program �e�nt ti� e � �z y Department **** VARIANCEIWAIVER REVIEW **** Waiver#: OSP121416 COSA#: PID#:020-042-70 Permit#: OSP121294 Legal Description: Ptarmigan Roost Block 2 Lot 2 Engineer: Anderson Engineering Applicant: Northwood Homes Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 2.0 feet. In addition, the field is approved to be 25' from the excessive slope created when the driveway was constructed. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: 12 Zg /Z Approved by: L/ a L .... Name of Revie er .......................... A.... 0..........made......;.................... Real: 02103G Amount: 200.00 Date Paid: 11/14/12 **** VARIANCE/WAIVER REVIEW **** E \' Community Development Department Phone: 907-343-7904 Development Services Division �� Fax: 907-343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWERlWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-042-70 Property owner(s): Northwood Homes Day phone: 694-5890 Mailing address: P.O. Box 92301, Anchorage, AK 99509 Site address: 16301 Luna Street, Anchorage, AK 99516 Legal description (Sub'd., Block & Lot): Lot 2, Block 2, Ptarmigan Roost Legal description (Township, Range & Section) Lot Size: 47,036 SF Number of Bedrooms: Three (3) THIS APPLICATION IS FOR: THIS APPLICATION IS AN: (E all that apply) Absorption Field X Initial X Septic Tank X Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Private Well X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. signature of property owner or authorized agent) Permit/Rush Fees: 5C, - ;L00 — Date of Payment: t l la C:V Receipt Number: Permit No. 05 0 d l _aM Waiver Fees: Date of Payment: Receipt Number: Waiver No CALlsersWndEng\Desktop%Mike1T15N Lot 1121Permit Application Lot 112.docC:IUsersV\ndEnglDesktop\Mike1T15N Lot 1121Permit Application Lot 112.doc Ca -o�-f ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) December 27. 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 2, Ptarmigan Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The owner of Lot 2, Block 2, Ptarmigan Roost Subdivision intends to construct a three bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. No existing wells are closer than 100' from the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trenches indicated gravel with sand and silt (GM). The percolation rate of the soil was determined to be 3 minutes per inch. Groundwater was found during the placement of the test holes at depths of 14' and stabilized at 10' during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system and the trench will be centered around Test Hole No. 3. We are proposing to place a new 1,250 -gallon STEP tank and a 50' long by 5' wide by 3' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 6'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the STEP tank. The ground surface on the lot in the area of the absorption trenches slopes to the west at a grade approximating 5%, but encounters a 1:1 driveway backslope 25' from the edge of the trench in the worst case and 40' in the best case . A waiver allowing the trench to remain less than 50' from the slope has been submitted. The new trenches Lot 2, Block 2, Ptarmitgan Roost September 11, 2012 Page Two Co4:"1 will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, W J- Michael E. Anderson, P.E. Attachments ;• 49th X %.* MICHAEL E. ANDERSON NO. CE -4381 CD l ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) November 10, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 2, Ptarmigan Subdivision Septic System Design and Permit Application Percolation Test No. 1 Dear Onsite Services Engineer: The percolation test completed in Test Hole No. 1 was performed by Jackson Berkram a summer employee with no experience in soils testing. This was the first test he performed without supervision. His results indicated a percolation rate of 27 minutes per inch. I was on site during the excavation of the test hole and the construction of the percolation bench. Soils encountered were gravel with varying degrees of sand and silt. Visually it appeared the soil would absorb water at a rate of less than 5 minutes per inch. I was surprised at the results from the percolation test performed, but did not perform a check test. Recently the absorption trench was excavated and the same gravel with silt and sand was discovered. The soils were inspected by both Jeff Poet of the City and Alan Harala representing Anderson Engineering. They both agreed the accepting soil was substantially better than the 27 minutes per inch would indicate. A percolation test was run with results indicating a rate of less than 5 minutes per inch. We are confident the rate over the entire trench is less than 5 minutes per inch. Sincerely, 181MI M1111:11Mdr1roM Tiwa:8 165TH AVENUE \\ 5 /// I vv / Septic / Area 8 QQ I� �\ Existing Well _________ ------------ __ 2 \ �\ -n= ------------ /tzisting Wel O LLJ \Rro�olsed Well LLJ U7 I I /® \' I SAreaiin �I Existing Well 44 � / r�� SSe Area �;� 8 i ® = � 11 1 66TH AVENUE Existing Well \ vv i / �0 414# 4p- Ar�p .......... ..... A 49th °;♦ AREA MAP .. :. �� MICHAEL E. ANEERSON ; �= ♦ ff •., No. CE-4381 SCALE V = 100' ♦♦♦, �, �� [ �:� ♦4,1,ii So'.��. i I I � Existing Well v`v 1 A \ 1B % Existing Well 1 I \ � � \\ Existing Well I A ®i I 1 \ 4B PLAT NO. 71-214 PTARMIGAN ROOST LOT 2, BLOCK 2 47,036 S.F. 89 233' N 89'26'30"E 223.98'(R) S 89'56'20`E 224.04'(M) 10' UTIL. ESMT. ------------------------------------------------ 30' --------------------- __—_—__---_ 30' n Proposed Well Z M D O J O e% DRIVEWAY 2Da' LEGEND MT — Monitor Tube FCO — Foundation Clean Out TH — Test Hole CO — Clean Out MH — Man Hole zpE � 5% \ 1,250 Gallon %o STEP Tank _x \ \ N N Three �edroom Home \\ S2 FCO St G. SLAB fO n EL. = 229' 0 0 In O O P ®T12 M N 89'26'30"E 223.98'(R) NOTE: No Areas of Excessive Slope or Surface Water are Within 100' of Any Part of the New Septic System with the Exception of the Cut Slope for the Driveway. SITE PLAN SCALE 1" = 40' ALTERNATE SITE: Advantex Treatment System with 30' Long x 5' Wide x 3' Effective Depth Absorption Trench. 2 GPD/SF Application Rate. ___ -=x sx i i „sx T13 >xi 50' Long x 5' Wide x 3' Effective Depth Absorption Trench244, ALTERNATE SITE: Advantex Treatment System with 30' Long x 5' Wide x 3' Effective Depth Absorption Trench. 2 GPD/SF Application Rate. ___ LOT 2, BLOCK 2, PTARMIGAN ROOST SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Three Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon STEP Tank Application Rate: 1.2 GPD/SF 3' Drainfield Rock 3 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 375 SF Absorption Area 375 SF/5 SF/LF*.58 (Red. Factor) = 43.5 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 3' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 100' Separation From Private Wells in the Area. Natural Backfill 2'6" Topsoil and Seed Outer 6" Geotextile Fabric 6" 1" Perforated PVC (Holes Down) 7/16" Diameter Hole 3'0" 30 Holes @ 1.5' Drainfield Rock 5' TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEP"I'H (feet) 1 - 2 - 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2, BLOCK 2, PTARMIGAN ROOST SUBDIVISION PERFORMED FOR: JIM JACKSON DATE: 6/15/2012 PROJECT No.: PARCEL ID#: TECHNICIAN: J. BERKRAM TEST HOLE I OL/OG SILTY GRAVEL WITH SAND GM/ML MOIST BOH @ 15' N 0 WAS GROUND WATER ENCOUNTERED? YES IF YES @ WtIAT DEPTH? " DEPTH OF WATER AFTER MOuTORINc. Io DATE OF MONITORMC 10/12/2017. SITE PLAN SEE SITE PLAN x J L _ p E g-10% READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) F7/T2'6 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 9:02 2.25" 2 9:32 30 3.50" 1.25" 3 9:33 2.00" 4 10:03 10 3.13" 1.13" 5 10:04 2.13" 6 10:34 30 3.25" 1.12" PERCOLATION RATE: 27 (MIN/INCH) PERC. HOLE DIA 10" (INCHES) TEST RUN BETWEEN: 3.0 FT. and 4.0 FT, COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS _ DATE: 9/11/2012 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2, BLOCK 2, PTARMIGAN ROOST SUBDIVISION PERFORMED FOR: JIM JACKSON DATE: 6/15/2012 PROJECT No.: PARCEL ID#: TECHNICIAN: J. BERKRAM DDPTH TEST HOLE 2 (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IT 18- 19- OL/OG SILTY GRAVEL WITH SAND GM/ML MOIST BOH @ 15' SLOPE WAS GROUND WATER ENCOUNTERED? YES IF YES @ WHAT DEPTH? I4' S DEPTH OF WATER AFTER MO DATE OF MO " . R] E. ANDERSON SITE PLAN FSEFE PLAN x i MONITORING, 10' L I 8-10% MONITORING: 10/12/2012 P E DATE IT TO READING GROSS TIME NET TIME D ATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/26 1 11:13 0.75" 2 11:43 30 2.00" 1.25`' 3 11:44 1.13" 4 12:14 30 2.38" 1.25" 5 12:15 1.00" 6 12:45 30 2.25" 1.25" PERCOLATION RATE: 24 (MIN/INCH) PERC. HOLE DIA. T (INCHES) TEST RUN BETWEEN: 3_0 FT. and 4_0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 911112012 PERCOLATION RATE: 24 (MIN/INCH) PERC. HOLE DIA. T (INCHES) TEST RUN BETWEEN: 3_0 FT. and 4_0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 911112012 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST C -C) ?�-i LEGAL DESCRIPTION: LOT 2, BLOCK 2, PTARMIGAN ROOST SUBDIVISION PERFORMED FOR: JIM JACKSON DATE: 11/5/12 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA DEPTH TEST HOLE 3 (feet) 7 8 9 10 11 12 13 14 15 16 17 18' 19 SLOPE WAS GROUND WATER ENCOUNTERED? NO IF YES @ WH DEPTH OF WATER AFTER MO DATE OF MO SI IE FLAN SEE SITE PN i DEPTH? NITORING NI NITORING'. P E DATE OL/OG GROSS TIME (MlNures) 2 DEPTH To WA(INCHES) TER NET DROP (INCHES) 3 a 1115 4 a SILTY GRAVEL 1.62" WITH SAND 5 a GM/ML 6 8.75" BOH @ U 7 8 9 10 11 12 13 14 15 16 17 18' 19 SLOPE WAS GROUND WATER ENCOUNTERED? NO IF YES @ WH DEPTH OF WATER AFTER MO DATE OF MO SI IE FLAN SEE SITE PN i DEPTH? NITORING NI NITORING'. P E DATE READING GROSS TIME (MlNures) NET TIME (HlNures) DEPTH To WA(INCHES) TER NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 1115 1 10:08 1.62" 2 10:38 30 10.37" 8.75" 3 10:40 1.37" 4 11:10 30 10.06" 8.69" 5 11:11 1.50" 6 11:41 30 10.19" 8.69" PERCOLATION RATE: 3.5 (MIN/INCH) PERC. HOLE DIAY (INCHES) TEST RUN BETWEEN: 6.0 FT. and 7.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. SOILS ENCOUNTERED WERE CONSISTENT THROUGHOUT ABSORPTION TRENCH AREA. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 11/10/2012 CC) -0- 1 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766(FAX) November 12, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 2, Block 2, Ptarmigan Roost Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The house location on the lot will require a steep cut slope to provide an 8% driveway grade. The absorption trench must be moved as close to the east property line as possible to allow separation from the cut slope. Placement of the trench at this location will have no adverse affect on the well or septic system on the lot to the east. Separation distance requirements are easily met. We therefore recommend a waiver be issued allowing the absorption trench and alternate site to be 2' from the east property line. Sincerely, Michael E. Anderson, P.E. V 49th GV * MICHAEL E ANDERSON ._ No. CE -4381 . C 0 -115� I ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766(F December 27, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 2, Ptarmigan Roost Subdivision Absorption Trench to Slope Waiver Dear Onsite Services Engineer: The house location on the subject lot will require a steep cut slope to provide an 8% driveway grade. The absorption trench can only be located a minimum of 25' from the break in grade greater than 25% at the north end due to the remaining space available on the lot. Most of the trench will be at least 35' from the slope edge. The accepting soils at the absorption trench location are clean sandy gravel with some silt with percolation rates less than 5 minutes per inch. Septic effluent will be absorbed downward and will not migrate to the west. We hereby request the trench be allowed to remain 25' from the edge of the cut slope at the north end. Sincerely, J Michael E. Anderson, P.E. Attachment •o�OFq a. ••�P�......... ..... 4 i 3 49th ••••: ♦♦ �...:................ .. ... :..... �An ,MICHAEL E. , ANDERSON�.0 or. �. ♦�f ••. NO. CE -4381 ♦1 T4,E tL _ •�c�: 44a_ FE59 O N N L4 Cn O n O U O O Ul O V � O �' o Cn � NnV �F— D c omm0 �7 z D C� 0rri �CnN�:u OmO O w O M Z7 O Ul o m z � C CD C) Ul G Cf -)o O �t U' �' moo InOg�•�.. _ 2D U �.Q OD O I i it I I o I I°roPerty (Line i Municipality of Anchorage °. On -Site Water and Wastewater Program Ky (907)343-7904 / s. E.. RUSIV Certificate of On -Site Systems Approval // Parcel I.D. 020-042-70 Expiration Date: (o 1. GENERAL INFORMATION Complete legal description Ptarmigan Roost, Block 2, Lot 2 Location (site address) 16301 Luna Street Anchorage, AK 99516 Current Property owner(s) Northwood Homes Day phone 694-5890 Mailing address P.O. Box 92301 Anchorage, AK 99509 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) — ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Three 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaivertVariance request for: Distance: Received by: Date: - -COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ (O 2s� 2yil IZU5 Waiver Fee $ Date of Payment 3lcaul lGl3 �A Date of Payment Receipt Numberya u Receipt Number COSA # 0)C1 b 1 ��S Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on=sib water"tply and/or wastewater disposal system is (are) safe, functional and adequate for the number�of bedrooms anill type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE System #1 Approved for 3 bedrooms System #2 Approved for _ bedrooms Disapproved Conditional approval for Phone 522-7773 bedrooms, with the following stipulations: Ge- _Th 01.16 t'0K G AY ( _-_-E l e- G -F-/ ,-t gy;� �(/ _ > Original Certificate Date: " Thd ni ty age Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7- ATTACHMENTS: COSA Checklist X Nitrate-Advisory. Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Nue sheer_f , c If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Ptarmigan Roost, Block 2, Lot 2 Parcel ID: 020-04-70 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y Date completed 11/10/12 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 260 ft. Cased to 43.5 ft. Casing height (above ground) >18 in. FROM WELL LOG AT INSPECTION Date of test 11/10/12 Static water level 9 ft. Well production 2.5 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate '176 mg/L Arsenic N/D ug/L Date of sample: 3/11 /13 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/STEP Tank size 1,250 gal. Number of Compartments 3 Foundation cleanout (Y/N) Y Depression over tank (YIN) N Date of pumping New Pumper Construction C. ABSORPTION FIELD DATA 41 9 - p.m - Collected by: J. Anderson Date installed 1/17/2013 Cleanouts (Y/N) Y High water alarm (Y/N) Y Date installed 1/18/13 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD System type Wide Trench Length 50 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 7 ft. Eff. absorption area 431 fe Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed 1/17/13 Size in gallons 250 "Pump on" level at 42 in. "Pump off" level at 42 in. Datum Bottom of Tank Cycles tested New Const. E. SEPARATION DISTANCES WELL ON LOTTO: Septic tank/lift station on lot >100' Absorption field on lot >100' N/A Public sewer main Sewer /septic service line >25' >50' Animal containment areas SEPTICIHOLDING TANK ON LOT TO: Manhole/Access (Y/N) _ High water alarm level at Y 44 in. Meets alar & circuit requirements? Y On adjacent lots >1 00' On adjacent lots >1 00' Public sewer manhole/cleanout N/A Holding tank N/A Manurelanimal excrete storage areas >100' Building foundation >5r Property line >6 Water main >10' Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: 2'*** Property line Building foundation >10' Water Service line >10' Surfacewater >100' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS *** Cao I nt I inp Waiver G. ENGINEER'S CERTIFICATION ! certify that, l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 3/21/13 COSA brown sheet_10-10-12.doc Absorption field >5' Surface water >100' Water main >10' Driveway, parking/vehicle storage >10' Iz J 1 t1=30' 30' PLAT NO. 71-214 PTARMIGAN ROOST LOT 2, BLOCK 2 47,036 S.F. LEGEND • FOUND 5/8" REBAR 0 FOUND REBAR WITH ORANGE PLASTIC CAP STAMPED "LS -6914" SET 5/8" X 30" REBAR WITH YELLOW PLASTIC CAP STAMPED "LS -6091" (R) RECORD DIMENSION PER PLAT NO. 71-214 (M) MEASURED DIMENSION THIS SURVEY (P) SINGLE PROPORTION MEASUREMENT (H) HELD DIMENSION PER PLAT NO. 71-214 GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 2000 E. DOWLING RD., SUITE ANCHORAGE, ALASKA 9950 PHONE 248-5454 GRID DATE SW3238 2/28/2013 F.B. JOB NO. 12-07 1 PRS22 I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE. o4V P��..OF...q� 5•�� i *;49TH • :��0 ................... *o P ..... x:..45 Je y A. GastaldiAV �Ofessiona� �-°c '�