Loading...
HomeMy WebLinkAboutSEACLIFF BLK 3 LT 8Ac cliff Block Lot 8A #011-221-27 SUBMITTAL euc 8 gnu Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSPI21295 PID Number: 011-221-27 ❑ New 21 Upgrade Name: Jamie Cooper West ABSORPTION FIELD ❑ Deep Trench E Shallow Trench ❑ Bed ❑ Mound Address P.O. Box 534 Willow, AK 99688 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 1.2 GPD/SF 8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4 Ft. Gravel depth beneath pipe 4Ft. Subdivision Block Lot Seacliff 3 8A Fill added above original grade 2-3 Ft, Gravel length 51 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines I FL SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 510 Ft' I Ft. Well >200' >200' N/A N/A >25, TANK El Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,250Gal. Surface water >100' >100' N/A NIA Material Number of compartments Lot Line >5' >10' N/A NIA Steel Two NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. RemarksExisting Absorption Pit Decommissioned in Pump on level at in. Pump off level at in. High water alarm at in. Accordance with Municipal Code. Pump make and model Electrical Inspections performed by PIPE MATERIAL Housetotank D3034 Tankto Installer drainfield D3034 PCN, Inc. Drainfield HDPE CO/MT D3034 Inspector MEA BENCHMARK (Assumed elevation) 100.Oft Inspecttiones: im 10/13/12 2"tl Location and description 10/14/12 3'" a Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL ..l�,L,gs Conditional Approval: Date 49TH '•� 10.or ..........................nN MICHAEL I- A7'40W4W W I. .•� �E-43 ���i �� 1qf •. -...0�Approv Date l It 'VorEssit � �,t Inspection Re—1-1-12.doc Page 2 of 3 PID No.:011-221-27 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Permit Number: OSP121295 A I B S1 43.5' 26.7' S2 8.4' 48.4-133.3- 33.3'C4 C4 C5 Mt 1 68.8' 50.7' SEACLIFF SUBDIVISION LOT BA, BLOCK 3 17,282 S.F. 70,700 00 ` t Existing Absorption Crib \ \ Abandoned in Accordance with Municipal Code. ` FCD 2� ��rvs 4r Foor ,, tae wore' LEGEND SV — SepticVent CO — Clean Out MT — Mondor Tube TH — Test Hole C \ 49th .` .....i.;I............... If..._...^........ PLAN AS BUILT SCALE 1' = 30' MICHAEL E. ANDERSON Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP121295 PID No. 011-221-27 PROFILE AS -BUILT No Scale E Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP121295 01122127000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Terephone: (907) 343-7904 Upgrade Permit Effective Dates: September 24, 2012 to September 24, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: SEACLIFF Site LegalAddress: SEACLiFF BLK 3 LT 8A G:2424 Owner/Address: WEST JAMIE COOPER PO BOX 534 WILLOW AK 996880534 Site Mailing Address: 5117 SHORECREST DR, Anchorage Lot Size in Sq Ft: Total Bedrooms: 17282 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notif~ the Development Services - Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERNVELL PERMIT APPLICATION Parcel I.D. 01%221-27 Property owner(s) Jamie Cooper West Mailing address P.O. Box 534 Willow, AK 99688 Day phone Site address 5117 Shorecrest Drive Anchorage, AK Legal description (Sub'd~, Block & Lot) Seacliff, Block 3, Lot 8A Legal description (Township, Range & Section) Lot Size 47,282 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING 1 PiO~ BOZ 240773 ~.CHORAGE AK 99524 $22-7~73 September 11,2012 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 8A, Block 3, Seacliff Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing septic system on the subject lot was originally constructed in 1966 and is undocumented. It has failed and must be replaced. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the four- bedroom duplex on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic systems. The existing septic crib will be decommissioned in accordance with Municipal Code and a new 1,250 Gallon Septic Tank placed at the location shown. A new absorption trench will be constructed in accordance with Municipal Code. Also identified on the plans are the locations of the existing well on this and adjacent lots and adjacent septic systems. No conflicts exist between the proposed septic system and the wells on this or adjacent lots. Protective radii are shown to the adjacent wells. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Well Graded Gravel with Sand and Silt (GM/SM) the entire depth. The percolation rate was determined to be less than 5 minutes per inch. We have designed the new trench with an application rate of 1.2 gallons per date per square foot. No groundwater was found in the test hole and none developed during the monitoring period. We are proposing to place a 50' long trench by 5' wide with a 4' effective depth. The total depth of the system will be 8' with the distribution line at 4' below the existing surface. The ground surface on the lot is virtually fiat in the area of the proposed absorption trench. The trench will be placed parallel to the contours of the ground as much as Lot 8A, Block 3, Seacliff September 11, 2012 Page Two possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the existing well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 1 0A 2O 9A 21 6 7A VACANT 22A AREA NAP SCALE 1' = 100' / / / / / / / / / / / / r',,- z ~-0 ox _d o o ~ E 7 I LOT 8A, BLOCK 3 SEACLIFF SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Duplex 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms * 150 GPD/Bedroom ~ 600 SF Absorption Area 600 SF/1.2 GPD/SF/5 SF (Width) .5 (Red. Factor)= 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench at the Location Shown. FlowlJne Elevation to be 4' Below the Existing Ground Elevation. Total Depth to be 8' Below Existing Ground. Provide 4' of Cover Over Septic Tank and 3' of Cover Over Absorption Trench. Maintain 200' Separation From Class A Well in the Neighborhood. Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfleld Rock TYPICAL 5' WIDE TRENCH SECTION 4700 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-0050 DEPTH (feet) 1 OL/OG SLOPE 2-- 3 4 5 SILTY GRAVEL 6 WITH SAND GM/SM ? 8 DRY 9 11 20- SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 8A, BLOCK 5, SEACLIFF SUBDIVISION PERFORMED FOR: JAI'41E COOPER WEST DATE: 8/25/2012 PROJECT No.: PARCEL ID#:. TECHNICIAN: IdEA I TEST HOLE1 I BOH @ IL,' SITE PLAN SEE SITE PLAN WAS GROUND WATER ENCOUNTERED? NO IF YES ~ WHAT DEPTH?.__ S DEPTH OF WATER AFTER MONITORING: NONE ~ 2 °/o -- .- DATE OF MONITOPJNG: 9/10/2012 DEPTH TO DATE READING GROSS TIHE NET TIME WATER NET DROP (HINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 9/1 1 2:12 .?5" 2 2:42 30 8.50" 7.75" 3 2:43 .63" 4 3:13 30 8.38" 7.75" 5 3:14 1.00" 6 3:34 30 8.75" 7.75" PERCOLATION RATE: 3.9 (MIN/INCH) PERC. HOLE DIA. 10" .(INCHES) TEST RUN BETWEEN: 3.5 FT. and 4.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUN1CIPLE GUIDELINES IN EFFECT ON THIS DATE: 9/11/2012