MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-561-08
Property owner(s) Verne Pomraning Day phone
Mailing address 11120 Great Dane Circle Anchorage, AK 99516
Site address George Court Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Rabbit Creek View & Heights Replat, Block 4V, Lot 15A
Legal description (Township, Range & Section)
Lot Size 24,943 Sq. Ft. Number of Bedrooms Two (2)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
([~ all that apply)
Absorption Field [] Initial [] Single Family (SF) []
(w/wo ADU)
Septic Tank [] Upgrade []
Duplex (D) []
Holding Tank [] Renewal []
Multiple Dwellings []
Privy [] (SF and/or D)
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_9-1-12.doc
ANDERSON ENGINEERING
P,O; BOX 240773
ANCHORAGE;AK 99524
$22~7773 ~77~7766 (FAX)
September 13, 2012
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~e~:
Lot 15A, Block 4V, Rabbit Creek View & Heights Subdivision Replat
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the subject lot intends to construct a new two-bedroom home on the lot.
We are therefore requesting a permit be issued for the construction of a new well and
septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed well and septic
system along with the alternate site. Also identified on the plans are the existing wells
and septic systems on surrounding lots. No conflicts exist between the proposed well
and septic system and wells or septic systems on adjacent lots. Drainage arrows are
shown on the site plan showing the grade and direction of flow on the lot. The drainage
pattern will not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption bed and alternate site
indicate the presence of sandy gravel with some silt for the first four feet (GM). The
gravel is underlain by tighter silty material. The percolation rate of the silt lense was
determined to be 30 minutes per inch. Groundwater was found during the placement of
the test hole at 7' below the surface and has remained at that level during the
monitoring period. An application rate of .4 gallons per day per square foot was used
in the design of the absorption system. We are proposing to place a new 1,000-gallon
septic tank and 2 new 25' long by 15' wide by absorption beds to treat and dispose of
the effluent generated in the house. The elevation of the distribution line in the
absorption beds will be at the existing ground surface and the total depth will be .5'
below ground. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over
the absorption trench and 4' over the septic tank. A flow splitter valve will be placed to
insure even flow to each bed.
The ground surface on the lot in the area of the septic system slopes to the west. The
new beds will be constructed parallel with the slope as much as possible in
conformance with Municipal requirements. The new septic system will be constructed a
Lot 15A, Block 4V, Rabbit Creek View and Heights Replat
September 13, 2012
Page Two
minimum of 100' from all wells and any surface water and 10' the proposed and existing
water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
.7
9
12
/
®
VACANT
16
Proposed Well
G EO/NG E COURT
18
19
AREA MAP
SCALE 1' = 100'
4700
DEPTH
(~et)
1
2--
3
4
5
6
7
8
9
11
MUNICIPALITY Of ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 10/12/2011
PARCEL ID#:
LOT 15A, BLOCK /4V, RAbbiT CREEK VIEW SUB.
VERN POMRANING
PROJECT No.:
TECHNICIAN:
NO ORGANIC LAYER SLOPE
GRAVEL W/SAND AND SILT
GH
SILT
HL
DENSE/DAHP
BOH @ 12'
A. HARALA
SITE PLAN
SEE SITE PLAN
WAS GROUND WATER ENCOUNTERED? YES
IF YES @ WHAT DEPTH~ 7' ~
DEPTH OF WATER AFTER MONITORING: 9/15/2012 p(~ 2% __
DATE OF MONITOPdNG: 7' ~_
E
I C 'N TES> IC 'N 'ES>I 0 'ES) Ic<'ES)
TEST HOLE PRESOAKED PR[OR TO TESTING:
10/12 I 2:15 ' 2,25"
2 2:45 50 3.50" 1.25"
3 2:/-*6 2.13"
/4 3:16 30 3.13" I.O0"
I 5 :5:17 2.00"
[ 6 3:/47 30 3.00" 1.00"
PERCOLATION RATE: 30 (MIR/INCH) PERC. HOLE D1A. 6" ~INCHES
TEST RUN BETWEEN: 4.5 FT. and 5.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. l, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUN1CIPLE GUIDELINES IN EFFECT ON THIS
DATE: 10/9/12
4700
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-,5050
DEPTH
(feet)
1
2--
3
4
5
6
7
8
9
11
20
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 10/12/2011
PARCEL ID#:
LOT 1SA, BLOCK 4V, RABBIT CREEK VIEW SUB.
VERN POMRANING
PROJECT No.:
TECHNICIAN:
No ORGANIC LAYER SLOPE
GRAVEL w/SAND AND SILT
GM
SILT
I'lL
DENSE/DAMP
BOH @ 12'
A. HARALA
SITE PLAN
WAS GROUND WATER ENCOUNTERED? YES
]F YES @ WHAT DEPTH
DEPTH OF WATER AFTER MONITORING: 9/15/2012 ~°/o
DATE OF MONITORING: 7'
DEPTH TO
DATE READING GROSS TIME NET TINE WATER NET DROF
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
10/12 I I:10 .63"
2 I:&O 50 1.75" 1.25"
5 1:4l .50"
4 2:11 50 1.50" 1.00"
5 2:12 .75"
6 2:&2 .50 1.75" 1.00"
PERCOLATION RATE: 30 (MIN/INCH) PERC. HOLE DIA. 6" .(INCHES)
TEST RUN BETWEEN: 4.5 FT. and 5.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. l, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE.'. 10/9/12