Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 4V LT 15ARabbit Creek View & Heights Block 4V Lot 15A #020-561-08 MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-561-08 Property owner(s) Verne Pomraning Day phone Mailing address 11120 Great Dane Circle Anchorage, AK 99516 Site address George Court Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Rabbit Creek View & Heights Replat, Block 4V, Lot 15A Legal description (Township, Range & Section) Lot Size 24,943 Sq. Ft. Number of Bedrooms Two (2) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING P,O; BOX 240773 ANCHORAGE;AK 99524 $22~7773 ~77~7766 (FAX) September 13, 2012 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~e~: Lot 15A, Block 4V, Rabbit Creek View & Heights Subdivision Replat Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of the subject lot intends to construct a new two-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption bed and alternate site indicate the presence of sandy gravel with some silt for the first four feet (GM). The gravel is underlain by tighter silty material. The percolation rate of the silt lense was determined to be 30 minutes per inch. Groundwater was found during the placement of the test hole at 7' below the surface and has remained at that level during the monitoring period. An application rate of .4 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000-gallon septic tank and 2 new 25' long by 15' wide by absorption beds to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption beds will be at the existing ground surface and the total depth will be .5' below ground. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. A flow splitter valve will be placed to insure even flow to each bed. The ground surface on the lot in the area of the septic system slopes to the west. The new beds will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a Lot 15A, Block 4V, Rabbit Creek View and Heights Replat September 13, 2012 Page Two minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments .7 9 12 / ® VACANT 16 Proposed Well G EO/NG E COURT 18 19 AREA MAP SCALE 1' = 100' 4700 DEPTH (~et) 1 2-- 3 4 5 6 7 8 9 11 MUNICIPALITY Of ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PERFORMED FOR: DATE: 10/12/2011 PARCEL ID#: LOT 15A, BLOCK /4V, RAbbiT CREEK VIEW SUB. VERN POMRANING PROJECT No.: TECHNICIAN: NO ORGANIC LAYER SLOPE GRAVEL W/SAND AND SILT GH SILT HL DENSE/DAHP BOH @ 12' A. HARALA SITE PLAN SEE SITE PLAN WAS GROUND WATER ENCOUNTERED? YES IF YES @ WHAT DEPTH~ 7' ~ DEPTH OF WATER AFTER MONITORING: 9/15/2012 p(~ 2% __ DATE OF MONITOPdNG: 7' ~_ E I C 'N TES> IC 'N 'ES>I 0 'ES) Ic<'ES) TEST HOLE PRESOAKED PR[OR TO TESTING: 10/12 I 2:15 ' 2,25" 2 2:45 50 3.50" 1.25" 3 2:/-*6 2.13" /4 3:16 30 3.13" I.O0" I 5 :5:17 2.00" [ 6 3:/47 30 3.00" 1.00" PERCOLATION RATE: 30 (MIR/INCH) PERC. HOLE D1A. 6" ~INCHES TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. l, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUN1CIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/9/12 4700 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-,5050 DEPTH (feet) 1 2-- 3 4 5 6 7 8 9 11 20 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PERFORMED FOR: DATE: 10/12/2011 PARCEL ID#: LOT 1SA, BLOCK 4V, RABBIT CREEK VIEW SUB. VERN POMRANING PROJECT No.: TECHNICIAN: No ORGANIC LAYER SLOPE GRAVEL w/SAND AND SILT GM SILT I'lL DENSE/DAMP BOH @ 12' A. HARALA SITE PLAN WAS GROUND WATER ENCOUNTERED? YES ]F YES @ WHAT DEPTH DEPTH OF WATER AFTER MONITORING: 9/15/2012 ~°/o DATE OF MONITORING: 7' DEPTH TO DATE READING GROSS TIME NET TINE WATER NET DROF (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/12 I I:10 .63" 2 I:&O 50 1.75" 1.25" 5 1:4l .50" 4 2:11 50 1.50" 1.00" 5 2:12 .75" 6 2:&2 .50 1.75" 1.00" PERCOLATION RATE: 30 (MIN/INCH) PERC. HOLE DIA. 6" .(INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. l, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE.'. 10/9/12