Loading...
HomeMy WebLinkAboutCAMPBELL CANYON LT 6Campbell Canyon Lot 6 #041 -01 1 -08 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ONSITE WASTEWATER INSPECTION REPORT Permit Number: OSP121346 PID Number: 041-011--419 d g 0 New ❑ Upgrade Name: Colony Builders ABSORPTION FIELD ❑ Deep Trench ❑✓ Shallow Trench ❑ Bed [:]Mound Address 9420 Vanguard Drive #A Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 -8GPD/SF 9.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5.8 Ft. Gravel depth beneath pipe 4.OFt. Subdivision Block Lot Campbell Canyon 6 Fill added above original grade 5-6 Ft. Gravel length 75 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines SEPARATION DISTANCE$ Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 Ftp One Ft. well >200' >200' N/A N/A >100' TANK ❑ Septic ❑ S.T.E.P. El Holding ❑ Other Manufacturer Anchorage Tank Capacky 1,250Gal. Surface water >100' >100' N/A NIA Material Number of compartments Lot Line >5' >10' N/A NIA Steel Two NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Septic Tank is 10 Gauge Steel. Pump on level at in. Pump off level at n. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPEMATERIAL Housetotank D3034 Tankto D3034 drainfeld Red Dog Excavation Drainfield HDPE CO/MT D3034 Inspector A. Harala BENCHMARK (Assumed elevation) 100.0a Inspectionts, dates: 12/4/12 2- 12/5/12 Location and description 3`° 5/23/13 41" Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL x,44 ...... At �Se1 Conditional Approval: Datear Mr ice,•' • ..N Mf Oee O ,••.. .•• •• ..•• .. � : MId1A@. E ANDH2SON . 2 c• . W Approved Date (0—«-/3 f��1�►s�� ���'' Insnenfinn Rannrt 1-t _17 nr Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT Permit Number: OSP121346 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 A B 444.4' 59.5' 48.2 66.9 75.9 62.1 70.8 79.2 51.0' 93.3' M2 51.1 91.4 LEGEND M1 - Monitor Tube FCO - Foundation Clean Out TH - Test Hole Cl - Clean Out FSV - flow Splitter Valve M SHIVALIK DRIVE n N 89'5832"E 49.23' Page 2 of 3 PID NO.: 041-011-08 1 1 1 -- 1 1 1 1 PLAT NO. 2005-118 \ I \ CAMPBELL CANYON u zea SUBDIVISION n e I ell `) \\Ir 2,07 o S.F. Four Bedroom House TH3 \ z I \ / ®H2 \' N� 6 \�- ' 0 g T- N i sl s M2 \\� 0.0 GZ M1 ®TH4 \\ �mo "92 I I c aIternate \\N ,Y W. �\ N I I \ \ N I STH1 o I I \ 0 I \ o I I \ \ O I I \ z I I \ I I I I Ar ice:' NV L I 49th EL PLAN AS -BUILT E. ANDERSON �Oc�ICH NO. CE -4381 SCALE V = 50' ra Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP121346 N �96.5 U) UU 1,250 Gallon Septic Tank NOTE: 10 Gauge Septic Tank Page 3 of 3 PID No. 041-011-08 No Groundwater No Bedrock 12-4-2012 PROFILE AS -BUILT No Scale 86.4 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1 - 2 3 4 5 6 7 8 9 10 - II 13 14 15 16 17 18 19 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 6, CAMPBELL CANYON SUBDIVISION PERFORMED FOR: CRowN POINTE HoMEs DATE: 12/4/2012 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA OB/OG TEST HOLE 4 b d d " a SILTY SAND WITH GRAVEL d SM d SITE FLAN SEE SITE PLAN it WAS GROUND WATER ENCOUNTERED? NO S IF YES @ WHAT DEPTH DEPTH OF WATER AFTER MONITORING: NONE 2% DATE OF MONITORING' 6/8/2012 a P E BOH @ 21' COMMENTS: TEST HOLE TO VERIFY LACK OF DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: PERCOLATION RATE: (MIN/INCH) PERC. HOLE DIA. INCHES) TEST RUN BETWEEN: FT. and FT. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/4/2013 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121346 Tax Code Number: 04101108000 Work Type: Septic Initial Permit Effective Dates: October 10, 2012 to October 10, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: CAMPBELL CANYON Site Legal Address: CAMPBELL CANYON LT 6 G:2044 Owner/Address: EGEMO JOE 1639 CYPRESS PT LADY LAKE FL 321592212 Site Mailing Address: Lot Size in Sq Ft: 52780 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either. A. Open and Close on the same day. B. Covered. sealed. and heated -to Drevent freezing _ -x •_ .. Special Provisions: Prior to construction, the 200' protective well radius must be staked by a registered land Surveyor.•., Received Issued By: MUNICIPALITY OF Community Development Department Development Services Division On -Site Water & Wastewater Program ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION o$ Parcel I.D. 041-011-x Property owner(s) Joe Egemo Day phone Mailing address 1639 Cypress Point Lady Lake, FL 32159 Site address Shivalik Drive at Aletha's Mountain Way Anchorage, AK Legal description (Sub'd., Block & Lot) Campbell Canyon, Lot 6 Legal description (Township, Range & Section) Lot Size 52,780 Sq. Ft. Number of Bedroomsa`� APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) - - Ab6orption Field 0 '° Initial 4 Single Family (SF) 0 (w/wo ADU) Septic Tank '`' Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. _.OL C.S_ '- t property owner or Permit/Rush Fees: S 3o (mi Date of Payment: Io I SII'a C Receipt Number. Permit No. OtA01 al 3`l Ia Permit Appj.1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) October 3, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Campbell Canyon Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The owner of Lot 6, Campbell Canyon Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The subdivision is currently served by a Class A Water System and no private well is required. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. Also identified on the plans are the existing Class A Well radius and septic systems on surrounding lots. No conflicts exist between the proposed septic system and the well or septic systems. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes were placed on the lot in the area of the absorption trench and alternate site during the subdivision phase. The logs indicate silty gravel with sand (GM). The percolation rate of the soil was determined to be 6-15 minutes per inch. No groundwater was found during the placement of the test hole and none was noted during the monitoring period. Bedrock was located at 14' to 16'. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 75' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4' below the surface and the total depth will be 8'. A minimum of Sof fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the northwest. The new trench will be constructed parallel with the contours of the slope as much as Lot 6, Campbell Canyon Subdivision October 3, 2012 Page Two possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 200' from the Class A Well and 100' from any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments �D 49th •�:� MICHAEL E. ANDERSON Nn. CE -4381 SHIVALIK DRIVE i7 M N 89'58'32"E 49.23' 1 1 1 1092' � I \ i septic Area I 2Io I n m I Il LOT 5 Z -11, N NA X 1096, FHousBedroom \\ I � \1108e. X o' u / A.C. DRIVE \ ti % rco co ®H3\\\\ Call Septi on W Z j Septic Tank z ,Y JS' Long x 5' Wille ® 2 4' 11.. a oopth / o. Absorption Trench / Atemote N site O G\ ._—Wahl Ramer NOTE: Prior to Construction the 200' Protective Well Radius must be Staked by a Registered Land o ®THI � \ Surveyor. ry I I \\ PLAT NO. 2005-118 \ VACANT a CAMPBELL CANYON SUBDIVISION o j j 52,780 S.F. \\\ \ z NOTE: I Subdivision is Served by a Class A Water System. No Conflicts with LEGENI Adjacent Septic Systems. D MT - Monitor Tube TH - Test Hole AD Clean Out AD T. E. EZ ap6, CO - Clean Out J '' N 5.43'12"E �����,OF 14 ..... ....:qC.. VACANT 0 ` 49th l V ............. 'MICHAEL E. ANDERSON No Areas of Excessive Slope or SITE PLAN `•� f No. CE -4381 Surface Water are Within 100' of Any Part of the New Septic System. SCALE 1" = 50' 3 LOT 6, CAMPBELL CANYON SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Four Bedroom Home 5' Wide Trench System Perc. Rate: 6-15 Min./Inch 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 4 Bedrooms * 150 GPD/Bedroom = 600 SF Absorption Area 600 SF/.8 GPD/SF/5 SF/LF*.5 (Red. Factor) = 75 LF Trench Length THEREFORE: Construct a 75' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) jrc NOTE: Grade Area Over Trench to Drain Away. C Minimum 6' Separation From Bedrock. JO..... Minimum 4' Separation From Groundwater. sx Minimum 200' Separation From Class A Well in the Area. � Minimum 100' Separation From Surface Water or Streams. MICHAEL E. ANDERSON 1. No. CE438i 0 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM 4700 SOUTH BRAGAW ANCHORAGE, AK 99519 SOILS LOG — PERCOLATION TEST PROJECT #: PERFORMED FOR: Sovthcentral Timber Development DATE PERFORMED: —5/8!2004 LEGAL DESCRIPTION' Lot 6. Campbell Canvon TEST HOLE # ? jOG/OL/PT NO S GH • i L IF YES, WHAT DEPTH? ,•� Silty Gravel s s •ts 14 t Lei. GM Bedrock asional Boulders - 20' WAS. GROUNDWATER ENCO_ 11MERED? NO S DEPTH OF WATER NET DROP L IF YES, WHAT DEPTH? 0 DEPTH OF WATER /�o�l�• P AFTER MONITORMG: S.S' E DATE: S^4r-0y SITE PLAN N See Site Plan See Site Plan READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start S/9/04 8:36 8" 1 9:06 30 S.S' 25- .5'Rechar a Recharge 9:07 r 2 9:37 30 5.75' 2.25' Recharge 938 8" 3 10:08 30 PERC RATE: 13.3 MIN./INCH FERC. HOLE DIAMETER: TEST RUN BETWEEN 50 FT. AND 6.0 T. COMMENTS Test Hale Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: AH I, tIICHAEL F. ANDERSON. CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/13/2004 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM 4700 SOUTH BRAGAW ANCHORAGE, AK 99519 SOILS LOG PERCOLATI PROJECT #: - ON TEST PERFORMED FOR: SouthcentralTimber Develooment DATE PERFORMED: 5/8/2004 LEGAL DESCRIPTION: Lot 6. Campbell Canyon TEST HOLE # 2 WAS GROUNDWATER ENCOUNTERED? NO IF YES, WHAT DEPTH? DEPTH OF WATER /�Q `t• AFTER MONITORING: DATE: s L 0 P E SITE PLAN N See Site Plan See Site Plan READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/9/04 8:45 8' 1 9:15 30 5.5` 25' —Recharge 9:16 8• 2 9:46 30 5.75" 2.25' Recharge 9:47 8' 3 10:17 30 PERC RATE: 13.3 MIN./INCH PERC. HOLE DIAMETER:_V TEST RUN BETWEEN 50 FT. AND 6.0 T. COMMENTS: Test Hole Pre Soa6ed Prior to Percolation Test. TEST PERFORMED BY: AN I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDUIINES ON THIS DATE: 5/13/2004 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM 4700 SOUTH BRAGAW ANCHORAGE, AK 99519 PROJECT #: SOILS LOG - PERCOLATION TEST PERFORMED FOR; Soutthrentral Timber Develooment DATE PERFORMED: —5/012004 LEGAL DESCRIPTION: Lot 6. Campbell Canyon TEST HOLE # 3 OG/DL/PT 7 17, Poorly Graded Gravel Medium to Dark Gray 25" - 4' Rocks GM with ML Clusters Intermittent WAS GROUNDWATER GROSS TIME NET TIME ENCOUNTERED? NO S 10:33 L. IF YES, WHAT DEPTH? 1 1 O DEPTH OF WATER At I It P AFTER MONITORING: 1D:44 E DATE: 2 Recharge See Site Pian READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/9/04 10:33 g- 1 1 10:43 10 Dry g- Rechar a 1D:44 g- 2 Recharge 10:54 10:55 10 Dryg+ 8- 3 11:05 10 PERC RATE: —125— MIN./INCH PERC. HOLE DIAMETER:. 6" TEST RLN BETWEEN,—LO—FT. AND. 6.0 T. COMMENTS: Test Hole Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: AN LMICHAEL_^` F• A� CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/13/2004 Municipality of anchorage On -Site Water and Wastewater Program 4' .r (907) 343-7904 s < Certificate of On -Site Systems Approval Parcel I.D. 041-011-08 1. GENERAL INFORMATION: Expiration Date:mwulIj Q0 �3 Complete legal description CAMPBELL CANYON: LOT 6 Location (site address) 10608 Aletha's Mountain Way *Anchorage 99507 Current Property owner(s) Michael Faust Mailing address Real Estate Agent 2. TYPE OF DWELLING: ❑X Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 717-9193 Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual .Individual Water Storage ❑ Holding Tank ❑ Community Class A Well ® Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee J� � Waiver Fee $ Date of Payment 5 Date of Payment Receipt Number -3:2 G/ Receipt Number V COSA # 5C 1 S � 6 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: L II �Z) In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or `L,.• "' encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, T,' i groundwater levels (that may fluctuate during the year), quality of construction (materials and ✓ workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and """"" ... "...... ' are outside the control of GEG. Satisfactory test results do not guarantee future performance of the ..... �...... system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of ��• .. .___,�- - • • • • •: the well or septic system. GEG makes no representation whether an alternative well or septic system np './ =hrey A. t?ornEss: can be installed on the property in the event either of the current systems fail to perform adequately in Q'�11 . ' Cr'-} 7 53 the future. The content of this report is for the sole benefit of the person/party that retained GEG to u� s.` �+ t `%1.•'* perform the evaluation. Reliance upon the information provided in this report by any other person or� ""' party (including subsequent property purchasers) is not authorized, nor will it confer any legal right � p o`esscn�^_ whatsoever. #AECC884 6. DSD SIGNATURE System #1 Approved for _�__ bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, OF (:3 yO.p//ter Jam' ON-SITE with the following tl latiWATER AND m WASToEV,IATER o PROGRA J Original Certificate Date: %91.2-o: i The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist x Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist Legal Description: CAMPBELL CANYON; LOT 6 Parcel ID: 041-011-08 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Well production at time of test gpm Date drilled Water storage tank volume gallons N �, Total depth ft Well disinfected for coliform test? ❑ Yes -*M Cased to ft ❑ Coliform bacteria is Negative ❑ Sanitary seal is functioning correctly Nitrate mg/L ❑ Nitrate less than MRL (ND) ❑ Wires are properly protected Arsenic ug/L ❑ Arsenic less than MRL (ND) Casing height (above ground) in. Collected by Date of flow test for COSA Date of Sample Static water level at beginning of test ft. Comments CLASS "A" PWSID #218642 B. TANK DATA Age of tank(s) 9 years Tank type/material SEPTI -TEE Measured operating fluid level in septic tank 50" FE -1 Standpipes/foundation cleanout per record drawing Date of pumping c' �"' /Z/ D. ABSORPTION FIELD DATA TRENCH C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: N/A Which system tested (date installed) 12/5/12 Adequacy test date 5/21/21 V ALL standpipes present per record drawing Results [DPass For 4 bedrooms Total measured depth from grade 15.5 ft (max) Fluid depth prior to test 5 in Measured depth to pipe invert from grade 11 ft (min) Water added 620 gal ❑ N/A — pressurized field New depth 17 in A-1 Monitor tubes go to bottom of effective. If not, state Elapsed time 120 min depth into effective ❑■ Code -required soil cover over field Final fluid depth 10 in ❑ System presoaked Absorption rate 600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NONE date of test) N/A Gallons introduced gallons If yes, enter date N/A Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' Yes if No ft Water Main > 10' Animal Containment > 50' ❑ Yes if No ft ❑ Yes if No ft ✓❑ Yes if No ft Water Service Line > 10' 0 Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway comment below Community Sewer Main > 75' ❑ Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Ul Yes if No ft Property Line > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: SHOWN ON AS -BUILT SURVEY. SEE ATTACHED DRAWINGS. Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100'✓❑ Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells > 200' ✓❑ Yes if No ft Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' ❑✓ Yes if No ft Water Service Line > 10' 0 Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS *APPROXIMATELY 200'. CANNOT BE ABSOLTELY CERTAIN WITHOUT WELL SHOWN ON AS -BUILT SURVEY. SEE ATTACHED DRAWINGS. G. ENGINEER'S CERTIFICATION o� 0F /� %�Q ........ . -q�,�4 l certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with p C� MOA COSA guidelines in effect on this date. .:. -.9-h. ... r ... * ............ ..l. . O ffr Garr s, 'CE 79 3 Q�9 '•i •�c�G COSA Checklist yellow sheet �Q P,o f e s slog°oma #AECC884 .1 o`d?-7►i L Mi@T 6 *VC9 V N IZ9-zoz MiiLO.9OoOO N ml AV �± • \1 G4 o• 0E •�CF • '� # n •IWP4. i AIF 06/0912021 07:02 8686770 APLUS PAGE 01 I/ SSp�IGHT F(U i, F'rS A FULL)L H�� i A+ HO SERVICES INC. 75C 1 E. 140th Avenue And orage, Alaska 9951.6 345-1890 CUSTOMER ■ ch—a , Faust ` 10608 Ai eflim Mountain My 6+Ue I,, MWO1 thy. usmc@�gmail.com � Blockv Lof . DESCR(PTION 1 w1D Gallons —N— ;';eptic .each Area Holding Tank ❑ PROBLEM%REA — CALL FOR MORE INFORMATION ❑ NEEDS To 13E DONE AGAIN IN 6 MONTHS I 90 Good Shap,, ❑ Sludge buildup on bottom ❑ Jim cap mlE sing or ❑ Cut standpipe to 1' above ground needs repla ging INVOICE # �= N., r jI Standpipes V° ❑ Floater on top ❑ Needs Septictrine �'�of • • f,G' 8p .; Municipality of Anchorage On-Site Water and Wastewater Program 4 (907) 343-7904 mill CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 041-011-08 Expiration Date: 1 [O `( 7 1. GENERAL INFORMATION Complete legal description CAMPBELL CANYON LOT 6 Location (site address) 10608 ALETHAS MOUNTAIN WAY,ANCHORAGE, AK 99507 Current Property owner(s) MICHAEL FAUST TRUST Day phone Mailing address 10608 ALETHAS MOUNTAIN WAY,ANCHORAGE,AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well: ❑ Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class A Well ® Public Sewer ❑ Public Water System ❑ WaiverNariance request for: Distance: Received by: i Lii . Date: ��/17 COSA to be released to the engineer, unless oth- ,1,7 uested by the engineer. COSA Fee $ JW- Waiver Fee $ Date of Payment gull ll? Date of Payment Receipt Number 0 GO(IAD Receipt Number COSA# 666 P11-10.6 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation_ Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD.,EAGLE RIVER,AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 8129/2017 THIS COSA DOCUMENT CANNOT BE USED TO TRANSFER TITLE UNLESS ALL VENDORS(ENGINEERING,SURVEYING,CONTRACTORS,ETC...ASSOCIATED WITH THIS COSA ARE PAID IN FULL AT OR BEFORE CLOSING. Engineers Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments,deficiencies or discrepancies exist. OF .41,q`Air1 `)4-• ' 4• Tli 6. DSD SIGNATURE System #1 Approved for Lr bedrooms. F tixti System #2 Approved for bedrooms. , s'', $ 7 16 ����/ L •c Disapproved. \ '' Fess OS•\' Conditional approval for bedrooms, with the following stipu atida0Ik((c((t „v.\TY OF �'�,1�, o , WATER o ER A ! ND m mW AST EWAMR =� PROGRAM I= /6.›,_SERVtG�s�' Original Certificate Date: oqi I 1 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory - ' ' Septic System Advisory Arsenic Advisory , , - - Well Flow Advisory Other COSA blue sheet 10-10-12.doc . . If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system _ Certificate of On-Site Systems Approval Checklist Legal Description: CAMPBELL CANYON LOT 6 Parcel ID: 041-011-08 A. WELL DATA Well type A If A, B. or C provide PWSID# 218642 Well Log (Y/N) Date completed Sanitary seal (YIN)Y Wires properly protected (Y/N) Total depth ft Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/1 00 mL Nitrate mg/L Arsenic: _ ug/L Date of sample: Collected by B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 12/4/2013.. Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 8/28/17 Pumper A+ C. ABSORPTION FIELD DATA Date installed 1215!201 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type WIDE TRENCH Length 75 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 15.5 ft. (Measured 8/28/17) Eff. absorption area 600 ft2 Monitoring tube Y Depression over field N Date of adequacy test 8/28/2017 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 3 in. Water added 620 gal. New depth 4.5 in. Elapsed Time: 10 min. Final fluid depth 3 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N _ If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) 'Pump on" level at in. "Pump off level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES -PUBLIC WATER WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 101+ Surface water 100'+ Wells on adjacent lots 200'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ _ Water main 10'+ Water Service line 10'+ Surface water 100'+ Driveway, parkinglvehicle storage 10'+ Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots 200'+ F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. '_s ,OF Engineer's Printed Name KENNETH M.DUFFUS Date 8/2912017 4 KENNI rU M. MA fir Al COSA canary sheet_2-6-15.doc 4 71 6 - O. Aar \`_�f • ® Municipality of Anchorage ° On -Site Water and Wastewater Program s (907) 343-7904 j VA a 1 Certificate of On -Site Systems Approval Parcel LD. 041-011-08 1. GENERAL INFORMATION Expiration Date: 12- - S ` / _�)_ Complete legal description Campbell Canyon, Lot 6 'Location (site address) 10608 Aletha's Mountain Way Current Property owner(,,) Colony Builders Inc. Day phone Mailing address 9420 Vanguary Drive # A Anchorage, AK 99507 Real Estate Agent. 2. TYPE OF DWELLING: I 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Four Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual I1 Individual Water Storage ❑ Holding Tank ❑ Community Class A Well 0 Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: Distance: Received by: ,� w Date:( sJt( ! COSA to be release(o thvengineer, unless otherwise requested by the engineer. COSA Fee $ 0/15411-0 Waiver Fee $ Date of Payment �O %3 Date of Payment Receipt Number Receipt Number COSA# /A3Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are)`safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection,=tt e on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD Sl System #1 Approved for y' bedrooms System #2 Approved for bedrooms Disapproved Date 6/3/2013 OF A4 400 � -* lk� 4918 Conditional approval for bedrooms, with the following 1-4381 By: o, d4 Original Certificate Date:_(p The•ung ali ' Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible forerrors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet ! :j , If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Campbell Canyon, Lot 6 A. WELL DATA C 218642 Parcel ID: 041-011-08 Well type lass A If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (YIN) _ Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate Arsenic ug/L Date of sample: g.p.m. ft. g.p.m. mg/L Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 12/4/13 Tank size 1,250 gal. Number of Compartments 2 Cleanouts (Y/N) Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Date of pumping New Const. Pumper Y I C. ABSORPTION FIELD DATA Date installed 12/5/13 Soil rating (g.p.d./ft2 or ft2/bdrm) •8 GPD/SF System type Wide Trench Length 75 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 14-15 ft. Eff. absorption area 600 fe Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For—bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed "Pump on" level at in. Datum Size in gallons _ "Pump off' level at Cycles tested Manhole/Access(YIN)— in. anhole/Access(YIN)_in. High water alarm level at Meets alarm & circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot N/A On adjacent lots N/A Absorption field on lot N/A On adjacent lots N/A Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line N/A Holding tank N/A Animal containment areas N/A Manurelanimal excrete storage areas _ SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5 Property line >5' Water main >10 Water service line >10 Wells on adjacent lots >200' ABSORPTION FIELD ON LOT TO: Property line >10 Building foundation >10' Water Service line >10 Surfacewater >100' Curtain drain None Noted Wells on adjacent lots >200' F. COMMENTS G. ENGINEER'S CERTIFICATION / certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 6/3/2013 COSA brown sheet 10-10-12.doc Absorption field >5' Surface water >100' Water main N/A Driveway, parking/vehiclestorage N/A in.