Loading...
HomeMy WebLinkAboutLYNN DALE LT 3ALynn bale Lot 3A #015 - 273 - 73 Municipality of Anchorage On -Site Water and Wastewater Program - (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP161338 PID Number: 015-273-73 Dwelling: 0 Single Family (SF) M Duplex (D) 17� Multiple (SF and/or D) Project: F -I New Upgrade Kari Ryerson ABSORPTION FIELD Z Deep Trench F-1 Shallow Trench El Bed F-1 Mound Address 11000 Zelma Circle, Anchorage, AK 99507 El Other Phone Number of Bedrooms Soil Rating depth from original grade ITotal LEGAL DESCRIPTION Depth to pipe invert from original grade 2.98 Ft. Gravel depth beneath pipe 6.02 Ft. Subdivision Block Lot Lynn Dale 3A Fill added above original grade Varies 1.27 — 2.75 Ft. Gravel length (2 x 321) 64 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 770 Ft' 2 10 Ft. Well 100+ 100'+ 100'+ NA NA TANK Z Septic El S,T.E.P. El Holding El Other ANCHORAGE TANK 1 2000 Gal. Surface Water 100'+ 100'+ 100'+ NA Material Number of compartments NA Foundation 5)+ 10'+ 5'+ NA TIFT STATION Manufacturer Capacity I Curtain Drain I NA 50'+ NA NA Remarks *None known. Existing field left in place Pump on level at in. Pump off level at in. High water alarm at in. as CAT III reserve per permitted des�gn, S.T. & service line insulated. Pump make and model Electrical Insp ctions performed by Tank to 3034 Drainfield 3034 CO/MT 3034 Inspector ARCTERRA BENCHMARK (Assumed elevation) 100 ft Inspection l't 7/28/17 Location and description ,�d7/28/17 31d 7/31/17 4 U, Bottom of siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engin Conditional Approval: Date TH go 7116 Approved Date I eer's Stamp moponUonRepurt-9-1-12.doc AS -BUILT SYSTEM DETAILS/SITE PLAN Permit OSP161338 LYNN DALE LOT 3A PID# 015-273-73 x LX-X-Xj W 0 bo GREENHOUSE ORIG.FIELD CAT III RESERVE 48.2' SPLITTE CO F NEW M 000 -GAL 0(\ SEP TANK T c 12.0' CO C H CO Co Q G IVIT C I MT Co TO 30.5' ORIG. C j FIELD ST HOLE 3E BARN/ NOT rn -ORAGE CONNECTED FC 86.0' BMI EXISTING P, LOT 3A 6 -BR HOUSE 42.o' PD 44.0' q SCALEi V 30' 0 A- =25,5' MON B -C=51.5' FINAL GRADE A -D=37.5' —nn— , (Rga� MTM FABRIC',,"", 'w -B-D=62.0' I UM"TION v I ARMS ORIGINAL GRADE 5 ov q'i A -E=72.0 (4 2000 GAL cu TANK T E3 79 0. —2,7795 <' B -E=90.5' cu SEPTIC K) SEWER ROCK A -F=89,5' B -F=107,5' TRENCH 1 94.3 94,15 A-Cj=98,0' 32' c B -G=110,0' TOR TUBE MONITOR TUBE > FINAL GRADE 97.6 A -H=96.0' n B -H=108,5/ SCALEi NTS MTER FABRW'\",,\ V I ARES 9' A -I=79.5' B -I=92,0' 9 2=7 2 A -J=78,0' T B-J=90V SEWER ROCK 6w TRENCH 2 KI Gr4a vM uj cn 32' Js Ado,, SCALEi NTS A, k"� ()F _j .4 _j PREPARED FOR: E or KARI RYERSON �_'�CT r 61 11000 ZELMA CIR, ANCHORAGE, AK 99507 ol CQ TH* FIELD BOOKS COMPUTED: 0 KENNETH M. D�;a V) CE -7116 BOUNDARY- N A DRAWN: Bmw ip, STAKING: CHECKED: SLS KIVID 7' Ao ASSUILT., SLS DATE: 08/21/17 ID '�?onsslo"I" -dir E Dwc, nLF_ GRID: NW1562 M No-* "�"Po'�'81JLTING gr. ACAD "LE' FILE 17-178 AK. 995-n o RITE&,,, ARcTERRA CONSULTINCr, INC 212 E. 51" Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 4 �0HSuITING Cq �K..5]'1-5� 'F KENNETH Mt AMUS w SOILS PERCOLATION TEST, rt, s Af s Performed for: Kari Ryerson Date Performed: 7/27/2017 Project: Lynn Dale Lot 3 TEST HOLE # TH 17-1 Depth Feet SEE ATTACHED SITE PLAN FOR HOLE LOCATION 1 m Org/OL - SM Was Ground water encountered? NO What depth? NA 2 SP/GP Depth to water after monitoring? NA Date? NA 3 4 PERC BENCH 5- 6- 7- 8- 9- 10- 11- 12- 1.3- 14- 15- 16- 17- 18- 19- HOLE PRESOAKED 20- PRIOR TO TEST Reading Date Gross Time Net Time Depth to Water Net Drop 1 7/27/17 1:00 - 6" - 2 1:10 10 min 1 12/16" 44/16" 3 * 1:11 - 6" - 4 1:21 10 min 1 13/16" 4 3/16" 5 1:22 - 6" - 6 1:32 10 min 1 14/16" 4 2/16" 7 * 1:33 - 6" - 8 1:43 10 min 1 15/16" 4 1/16" 9 1:44 - 6" - 10 1:54 10 min 1 15/16" 4 1/16" 11 1:55 - 6" - 12 2:05 10 min 1 14/16" 4 2/16" Water Added Percolation Rate 2.4 (min/in) Perc Hole Diameter 6" Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161338 Tax Code Number: 01527373000 Work Type: Septic Upgrade Permit Effective Dates: December 13, 2016 to December 13, 2017 Design Engineer: PANNONE ENGINEERING SERVICES Subdivision: LYNN DALE Site Legal Address: LYNN DALE LT 3A G:2635 Owner/Address: RYERSON IAN M & KARI 11000 ZELMA CIRCLE ANCHORAGE AK 995160000 Site Mailing Address: 11000 ZELMA CIR, Anchorage This permit is for the construction of: Lot Size in Sq Ft: Total Bedrooms: cnr ail )JC���U•CI'I1C'llr 71816 .'y 0 Y Disposal Field I Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: At time of construction, 12 inches of clean water will be added to the percolation hole (twice). If it seeps away within 10 minutes, construction may begin immediately. If the 12 inches of water does not seep away in 10 minutes, a percolation test will be ran continuously until two consecutive water drop readings are within 1/16th of an inch. All readings shall be recorded and submitted to MOA Onsite. MOA is to be notified 2 hours prior to conducting this test. Receive ate Issued By: k&010A "S Date f� C la 12nar- 3 ko Municipality of Anchorage On -Site Water and Wastewater Program r (907) 343-7904 s At T CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-273-73 Expiration Date: 1. GENERAL INFORMATION Complete legal description LYNN DALE LOT 3A Location (site address) 11000 ZELMA CIRCLE, ANCHORAGE, AK 99507 Current Property owner(s) KARL RYERSON Mailing address Real Estate Agent 509 LOCUST STREET, RENO, NV 89502 2. TYPE OF DWELLING: Z Single Family (w/wo ADU) 0 Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone Day phone 3. NUMBER OF BEDROOMS: 6 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual 1Z Individual Well Holding Tank D Individual Water Storage El Community D Community Class_ Well El Public Sewer ❑ Public Water System 1-1 WaiverNariance request for: Distance: Received by: COSA to be released to the engineer, otherwise requested by the engineer. Date: A,_ / / 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTER.RA CONSULTING INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD., EAGLE RIVER AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 8/22/2017 WITH THIS COSA ARE PAID IN FULL AT OR BEFORE CLOSING. Engineers Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. t 6. DSD SIGNATURE ,4 9TI1 f a System #1 Approved for �_ bedrooms. System #2 Approved for bedrooms. Disapproved. Conditional approval for bedrooms, s I NTETH M. DU fof 'c (116 cyq n�PEss 0 with the following stipulations: WATER AND VMSTEWA I Pr,nGRAz. s By: Original Certificate Date: la/90/17_ The Municipality of Ancho ge Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc Legal Description: LYNN DALE LOT A. WELL DATA Kmore than 1septic system isonthe lot: CD8AChecklist #u__ Structure served by this system Parcel |D: 015 -273 - Well type PRVT M6-273 VVel|type{lyT |fA`B.orCprovide PVVS|D#Well Log (YYN) Date completed 7/2611{03 Sanitary seal (Y/N)Y Wires properly protected (YYN)y Total depth _i61 ft. Cased ho_161ft. Casing height (above ground) _12±in. FROM WELL LOG AT INSPECTION Date oftest 712611983 Static water level 151 ft. Well production 10 g -p -m- Co0bnn NEG colonies/100mL Nitrate 2.85 mg/L Arsenic: ND ug/L Date ofsample: 1B880YT TonkType/Nabshn| SEPTIC I STEEL Tank size 2000 gal. Number ofCompartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) Date of pumping NA - NEW TANK Pumper C. ABSORPTION FIELD DATA 8-8-2017 140 ft. g.p.m. Collected by: ARCTERRA Date installed 7/28/1 Clemnouts (Y7N) High water alarm (Y/N) N Dote installed 7128117 Soil rating (o4d mc or*c»`arn) 1.2System type DEEP TRENCH Length ft Width 2.5 ft. Gravel below pipe _6lC2ft. Total depth 10.27+ ft. (Measured 8/8/17) Eff.absorption area 7r»*u Monitoring tube y Depression over field N Date ofadequacy test Results (Paea/Fai|)___ For bedrooms Fluid depth inabsorption field before test in. Water added____gal. New depth___in. Elapsed Time: min. Final fluid depth ___in. Absorption rate >=g.p-d- Anynejuvenationtnsotment(pasi12mn.)(Y7N&type) N |fyes, give date________ D. LIFT STATION Date installed "Pump on" level atin. Datum E. SEPARATION DISTANCES WELL ONLOT TO: Septic tank/lift station onlot Absorption field onlot Public sewer main Size ingallons ________ "Pump off'leveu\in. Cycles tested M(Y/N)_ High water alarm level at Meets alarm & circuit requirements? On adjacent lots Onadjacent lots Pub|icsewer manhole/cleanout 100'+ Sewer /septic service line Holding tank Aohna| containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ONLOT TO: Building foundation Property line _f/± Absorption field Water main 10'+ Water service line 101+ Surface water 100'+ Wells onadjacent lots _iO0'+_-__- ABSORPTION FIELD ONLOT TO: in. Property line Building foundation _t8'+Water main Water Service line _1O'+Surface water Ddvowey.padkingkmhicle storage 10'+ Curtain drain. Wells onadjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION / certify that /have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA C0&4guidelines ineffect onthis date. OF A - -v4 41 Engineer's Printed Name - KENNETH M. DUFFUS Date ' + COGAcanary sheet 2-6'15.do 3SnOHN3TJO 3snOHN33�JO Iq 0 0 F X-X-Xl X X-X-X- "IS3 30VNIVK 9L iNS3 Ainiin soL ,LZ*022 M,, L2,6q.69N 0) 00 c3i Ul) 0 C\j z < Ld O� m (D tf) U- N 0 0 V) M < / °t 'o Q) LO 0 M M W 02 LLQ 8 6 V) (� , L2'60 L ll,,O-Y,69.62N) -CQ ECtS 0 CD 4 00 Q M Z-V'60L 3,,/9,99>68S -0 7-1 uCt2 TIMID E- LO w vwrlaz INS3 30VN[Vd(I 9'/ wm D cq 0 C) CJ 0 0. - S bD cn ate co 00 s IS -1 04 W --D Ls, -ION >01 I r�-Io 1 8- 0 0:<g) P— ED - u 4) LIJ Q > 0, < ti 4� E z < 0 0 �S 0 X— � z 0d 0'.0 =0 0 z u w < ei U) 0. >01 C) ai IOU ,O'Z* 3snOH b z ONIISIX3 CL 0 y 0 oW 30VNOJs NV8 3S60H 6 6.ZL co E- 08 V z bl 1 C� w w > il. If 3SnOHN3TJO 3snOHN33�JO Iq 0 0 F X-X-Xl X X-X-X- "IS3 30VNIVK 9L iNS3 Ainiin soL ,LZ*022 M,, L2,6q.69N 0) 00 c3i Ul) 0 C\j z < Ld O� m (D tf) U- N 0 0 V) M < co m 9 LLC 'o Q) LO 0 M M W 02 8 6 V) 4-a 0 -CQ ECtS 0 CD 4 00 Q M Ud -0 7-1 uCt2 LO wm D cq 0 C) CJ 0 0. - S bD co m 'o o 8 6 V) 4-a aj -0 uCt2 LO wm D cq 0 C) CJ 0 0. - S bD cn ate co 00 s IS -1 04 W --D -ION >01 I r�-Io 1 8- 0 0:<g) P— ED - u 4) Q > 0, ti 4� E z u tn 0 0 �S 0 X— > 0'.0 =0 0 z u 10 U) 0. >01 Municipality of Anchorage On-Site Water and Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-273-73 Expiration Date: 1. GENERAL INFORMATION Complete legal description Lynn Dale Lt3A Location (site address) 11000 Zelma Cir., Anchorage Ak. 99516 Current Property owner(s) Peter & Lori Hackenberger Day phone Mailing address '~ 1000 Zelma Cir., Anchorage Ak. 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: [] Single Family (w/wo ADU) [] Duplex [] Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class __ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual [] Holding Tank [] Community [] Public Sewer [] Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSAFee $ ~ Date of Payment Receipt Number COSA# Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OFINSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site System s Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone En.q neer nq Services LLC Address P;O. Box 1002171Anchoraqe, AK 99510 Engineer's Printed Name Steven R. Pannone Phone 272-8218 DSD SIGNATURE System #1 Approved for. bedrooms. System #2 Approved for. bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: By: ~~"/~ ~~- Original Certificate Date: / ~)'~ ~L.- ~ ~ The ~ iP i~tY f/f c~horageDeveloprnentSelv ices Division (DSD) issues Certificates ofOn-SiteSystems Appr0val(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or orniss[ons in the professional engineer's work. ATTACHMENTS: COSA Checklist X Septic System Advisory .~ Well Flow Advisory Nitrate Advisory Arsenic Advisory Other COSA blue sheet_9-1-12.doc If more than '1 septic system is on the lot: COSA Checklist # of Structure served by this system __ Certificate of On-Site Systems Approval Checklist Legal Description: Lynn Dale Lt 3A A. WELL DATA Well type P~v,~e 7/26183 Date completed __ Totaldepth 161 ff. IfA, B, or C provide PWSID #__ Sanitary seal (Y/N) Y Casedto 161 ft. FROM WELL LOG 7/26/83 Parcel ID: 015-273-73 Date of test Static water level 1 51 ft. Well production 1 0 g.p.m. WATER SAMPLE RESULTS: Coliform ~E~ colonies/100mL Nitrate ~.~[mglL Arsenic: /~')~ ug/L date of sample: IO--,~-f%~ Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 13 AT INSPECTION 9/28/12 137 5.1 in. g.p.m. Other bacteria ~ colonies/100 mL Collected by: ~ ~ ~-~ B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel Tanksize 1250 gal. Foundation cleanout (Y/N) Y Date of pumping 12/5/1 1 Date installed 1 1/31/83 Number of Compartments 2 Cleanouts (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N/A Pumper Northland Pumping Service, Inc. C. ABSORPTION FIELD DATA Date installed 11/31/83 Soil rating (g.p.d.l~ or ~/bdrm) 450 sf/bd Length 52 ft. Width 1.5 ft. Total depth 9+ ft. Eft. absorption area 624 ~ Monitoring tube Y Date of adequacy test 9/28/12 Results (Pass/Fail) Pass * Fluid depth in absorption field before test 68 in. Water added 600 gal. Elapsed Time:__144° min. Final fluid depth 68 in. Any rejuvenation treatment (past 12 mo.) (YIN & type) N System type Trench Gravel below pipe 6 ft. __ Depression ever field N For 4 bedrooms New depth 72 in. Absorption rate >= 600-t' g.p.d. If yes, give date LIFT STATION Date installed "Pump on" level at__ in. Datum Size in gallons "Pump off' level at__ in. Cycles tested Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ Absorption field on lot '100+ Public sewer main 75+ Sewer/septic service line 25+ Animal containment areas 100+ ** SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Water main '~ 0+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Water Service line '~ 0+ Curtain drain 50+ On adjacent lots 100+ On adjacent lots 100+ Public sewer manhole/cleanout 100+ Holding tank 100+ Manure/animal excrete storage areas 100+ Property line 5+ Water service line 10+ Absorption field 5+ Surface water 100+ Building foundation 10+ Su#ace water 100+ Wells on adjacent lots 100+ Water main 10+ Driveway, parking/vehicle storage 10-1' F. COMMENTS * This system has used 94% of its operational life. ** Animal containment/shelters have been removed. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Pdnted Name Steven R. Pannone Date ~ '~"i~ g)/'~.~~ COSA brown sheet_9-1-12.doc Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Septic System Advisory Certificate of On-Site Systems Approval # oscl21478 During a recent adequacy test on the septic system for Block , Lot 3A of Lynn Dale subdivision, 68 inches of standing water was observed in the absorption field. This indicates that approximately 94% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval