Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FIRE LAKE HEIGHTS LT 1B
Fire Lake Heights Lot 1 B #051-351-33 Inspection Report_1-1-12.doc Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121388 PID Number: 051-351-33 ❑✓ New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD ❑ Deep Trench 0 Shallow Trench ❑ Bed ❑ Mound Address 165 E. Parks Hwy, Suite 200 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 357-9394 4 1.2GPD/SF 7.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.5 Ft Gravel depth beneath pipe 4.OFt Subdivision Block Lot Fire Lake Heights 1 B Fill added above original grade 0-1 Ft, Gravel length 50 Ft, Township Range Section Gravel width 5Ft. Beds: Number of Lines. Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 500 Ft' One Ft. Well >100' >100' N/A N/A >25, TANK p Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1 1,250Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' >10' NIA N/A Steel Two NA Foundation >5' >10' NIA NIA LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at in. Pump off level at in. High water alar at in. Pump make and model Electrical Inspections performed by Installer PIPEMATERIAL HousetotankD3034 Tankto D3034 drainfield _ Northern Excavation Drainfleld F810 Co/MT D3034 Inspector MEA BENCHMARK (Assumedelevatiori) 100.Oft Inspecttiones: 1" 10/30/12 2�a 10/30/12 Location and description s" a Garage Slab. COMMUNITY. DEVELOPMENT DEPARTMENT APPROVAL Conditional Approval: Date 491H N• N°. °N°Ne�N•q Approved Date/ /?j ��� FESS1 Inspection Report_1-1-12.doc Permit Number. OSP121388 Lot 2 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Lot 1 B 43,560 s.f. 12.1' 21.9' M1 34.1'177.5'1 C5 30.1-1 36.7' M2 1 30.5'138.6' Lot 1 A LEGEND C4 — Cleanout S1 — Septic Vent FCO — Foundation Cleanout TH — Test Hole M1 — Monitor Tube COLLETT DRIVE WALKER TRACT Lot 5 Alternate Site ®TH2 TH1® M1 M2 C41 I Four Bedroom Home COLLETT TRACT PLAN AS BUILT SCALE V = 40' 0 Well Lot 3A I y. 49th MICHAEL E. ANDERSON y -4381 No. CE Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit Number: OSP121388 PID No. 051-351-33 89.3 85.3 96.4 N /-94.8 N 1,250 Gallon STEP Tank zSf H n 93.3 n 92.8 Drainfleld Rods 85.3 77.8 50' (Trench No Groundwater � 10-2-08 89.3 I r 49th W PROFILE AS -BUILT /:MICHAEL E. g �{:Crsa:,. No. CE-4433ERS N 81 , No Scale M Permit Number: OSP 4213se Date of Issue w2wm Parcel identification Number: m3stnotto Date Started: 111112012 Date Completed— 1111rM2 is well located at approved pamt location? X Yes _JT3o Property DmTrlrtioa FIRE LAKE HEIGHTS Lot 18 Block Seaton: Town: Range: Property Owner Name & Address: TROY DAvtB wmEs 165 E. PARKS FflMY. #2048 WASILLA, AK 99VA Borehole Data: Depth Method of Drilling jx j air rotary cable tool Soil Type, Thickness & Water Strata From To Casing type: Casing Stickup a 2 Wall thickness o.2s inches Overburden 2 a Diameter 6 inches Total: ..._t02 feet Sand & Gravel 4 e2 L,iner type: Diameter inches Depth: feet Sand Gravel Sift 52 88 ----u -- Casing stick-np above ground: _2 feet Static Water Level(from top of easing) 125 feel Gray Bedrock Sot 85 1e0 BramBedrock 18e. 185 .Pumping Level: feet after —...._—_ Gray Bedrock 18s 187 _ .1. _ Hours pumping 45Cxpt3 Brown Bedrock 167 .199 RomVery Rate 45;6iP¢¢ _. Method of Testing- Air Grey Bedrock 199 218 Well Intake Opening Type Pink Bedrock 218 222 1...-1 Open End Ix } Open Hole n Screened Start feet Stopped feet X] Peribintions Start so feet Stopped 57 feet Grout Type: Bentonite dry granular Volume: S8 Pourer Depth 44 Start a feet Stopped 44 feet Pump Intake Depth: feet Pump size: HP brand name Well disinfected upon Completion? JX # Yes U No Method of disinfection CHLORINE 50 PPM Comments: WELL PRODUCES 45 GPM. PERFORATED AT 75- 85 FEET ALSO. Water Sample Results: Arsenic: N p ugtl Won Urmer• —_....._ GolasuYksu Nitrates ,2, 6 CIO Su"hum Water Waf: ... Total Coliform Bacteria �I t _colonies100mi Box 67026q Chug 7 Attention: The property owner shall provide this Iog to DSD (mite) and DNR within 30 days of completion. Parcel Identification Number: t6 I �5 I � V0 Legal Description L ct Pump Installation Date: Pump Intake Depth Below Top of Well Casing. feet Pump Manufacturer's Name i t < Pump Model: i, Pump Size hp Pidess Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: : ., 4 b,, , , , -,, Pitless Adapter Installer: I. - Well Disinfected Upon Completion? &[Yes No Method of Disinfection: Comments: Pump Installer Name. )yerty Owner Name & AddreE S A F E - y Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump, installation C lWater Mafk Begich A 995r,,7 Mayor r Pump Installation Log Well Drilling Permit Number: lvf i/,a, ;kdl fO Date Of Issue: Z& --P Y/ ,- Parcel Identification Number: t6 I �5 I � V0 Legal Description L ct Pump Installation Date: Pump Intake Depth Below Top of Well Casing. feet Pump Manufacturer's Name i t < Pump Model: i, Pump Size hp Pidess Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: : ., 4 b,, , , , -,, Pitless Adapter Installer: I. - Well Disinfected Upon Completion? &[Yes No Method of Disinfection: Comments: Pump Installer Name. )yerty Owner Name & AddreE S A F E - y Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump, installation On -Site Water & Wastewater System Permit Permit Number: OSP121388 Tax Code Number: 05135133000 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Work Type: WellSeptic Initial Permit Effective Dates: October 29, 2012 to October 29, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: FIRE LAKE HEIGHTS Site Legal Address: FIRE LAKE HEIGHTS LT 1 B G:0454 Owner/Address: OLMSTEAD KATHI 19436 LAURA LEE EAGLE RIVER AK 995778415 Site Mailing Address: 18511 COLLETT DR, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank l0 -30-12. E 1:O'D Lot Size in Sq Ft: 43560 Total Bedrooms: 4 N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. /0131//z GDS( well rv.V j -1v Ae eas'Y Received By: f� /12 . Z_9 '-t Z_— Issued i Issued By: /I Zl/�0-(�_�$ Date: MUNICIPALITY OF Community Development Department Development Services Division On -Site Water & Wastewater Program 10 11 h R�SHI . ANCHORAG , OCT �2t)12 Phone: 907-3 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-351-33 Property owner(s) Troy Davis Homes Day phone 357-9394 Mailing address 165 E. Parks Highway Wasilla, AK 99654 Site address 18511 Collett Drive Eagle River, AK 99577 Legal description (Sub'd., Block & Lot) Fire Lake Heights, Lot 11B Legal description (Township, Range & Section) Lot Size 43,560 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Q Initial FX1 Single Family (SF) Q (w/wo ADU) Septic Tank Q Upgrade ElDuplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. property owner or authorized agent) Permit/Rush Fees: 'J6b- lolm - DateofPayment: 10 h A ! I'a. r�n Receipt Number: c� '7)4�15 Cn Permit No. 05MW 3>%V Permit App_.-: 1Waiver Fees: Date of Payment: Receipt Number: Waiver No. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) October 28, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 113, Fire Lake Heights Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The owner of Lot 1 B intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The lot will be served by a private well. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. No existing wells are closer than 100' from the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the tract in the area of the absorption trench and alternate site indicated silty gravel with sand (GM) material. The percolation rate of the soil was determined to be slightly more than 1 minute per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 50' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 7'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the northwest at a grade of 5%. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any Lot 113, Fire Lake Heights October 28, 2012 Page Two surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Si�ncer�ely, Q Michael E. Anderson, P.E. Attachments MICHAEL E. ANDERSON .. No. CE -4381 C of OLIVIA DRIVE / \\ I I 1 O I I . I I i v2 Exiwrq wen I i t;� / (ll\ { 3 �\ w ow•II —f--- I Septic ire• / \\ \ --tom/ / \ � I F atln9 Well 1A \ 1 \� 4gr Pwd l g _ / s WALKER] TRACT �,\ O g I cau • a I I w•n �\ C04LETT TRACT �r9�♦ ■ 49th : ■ i..MICHAEL EAESO��... ■ ■ AREA M A P ■ �� F •••!0 `tom/-/„ ♦♦ ����; ;pESS ; SCALE 1" = 100' FIRE LAKE HEIGHTS SUBDIVISION LOT 1 B 43,560 S.F. 10' T & E Easement ---------------------------------------- Alternate S{te t 50' Long ti 5' Wide O,6l2 ®TH2 TH1�Co Absorption t�Tencve hpth COLLETT DRIVE .��orrrpr,a OF q��� LEGEND ����Q ,.••j. TH — Test Hole CO —Clean Out 41 MT — — Monitor Tube 49th ••°: �� FCO — Foundation Clean Out ' '""' 2CO — Double Clean Out ........ . C:.MICHAEL E. ANDER -4381SON NO. CE -4381 ..i _ - SITE PLAN ✓`t•�f�, ti, r_ a _ � O SCALE 1° 40' QUTAA MT 2C0 SV �• 1,250 Gallon sv Septic Tank / FCO \ N \ 00 � N OFour Bedroom W Home \ 0 O 00 � O O O O 1 Z 0 O ` b O Z 0 Proposed Well NOTE: No Slopes Greater than 25% Within / 50' of the Proposed Septic System. No Surface Water Within 100' of the / Proposed Septic System. N89°49'13"W 175.54' COLLETT DRIVE .��orrrpr,a OF q��� LEGEND ����Q ,.••j. TH — Test Hole CO —Clean Out 41 MT — — Monitor Tube 49th ••°: �� FCO — Foundation Clean Out ' '""' 2CO — Double Clean Out ........ . C:.MICHAEL E. ANDER -4381SON NO. CE -4381 ..i _ - SITE PLAN ✓`t•�f�, ti, r_ a _ � O SCALE 1° 40' LOT 1 B, FIRE LAKE HEIGHTS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Four Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Aplication Rate) = 500 SF Absorption Area 500 SF/5 SF/LF-.5 (Red. Factor) = 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 7' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. Natural Backfill 2'6" Geotextile Fabric 6" 4" Perforated PVC (Holes Down) 4'0" 5' Drainfield Rock DEEP TRENCH SECTION NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS � ISOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: FIRE LAKE HEIGHTS; LOT I PERFORMED FOR: KATHI OLMSTEAD DI DEPTH (feet I %—;zz] ORGANICS ITEST H=# 1 OIL CLASSIFICATIONS FIRE LAKE HEIGHTS, LOT 5 IQOM ii -y WA PERCOLATION RATE 1 (MIN.IINCH) PERC, HOLE DIA, 6 (INCHES? 2'0" TEST RUN BETWEEN 6 FT. AND 7 FT. A FOUR HOUR PRESOAK WAS PERFORMED: El YES E NO SOILS LOGGED BY: KYLE MAUS _ PERCOLATION TEST PERFORMED BY: KYLE MAUS PERFORMED BY DEC, Ltd, 1, JEFFREY A. HARNESS, CERTIFY THAT THIS.! PERFORMED IN ACCORDANCE it�WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: " I rPROPOSED READING CLOCK TIME NET TIME (MINUTES) UBUDIVISIONNE NET DROP (INCHES) 10/2/08 1 2:30 — 6. TH#2 THil 1 2 2:36 6 0 6" 3 2:36 — 4 2:42 6 0 6. APPROXIMATE — 6- WATER LINE 6 2:45 LOCATION. PERCOLATION RATE 1 (MIN.IINCH) PERC, HOLE DIA, 6 (INCHES? 2'0" TEST RUN BETWEEN 6 FT. AND 7 FT. A FOUR HOUR PRESOAK WAS PERFORMED: El YES E NO SOILS LOGGED BY: KYLE MAUS _ PERCOLATION TEST PERFORMED BY: KYLE MAUS PERFORMED BY DEC, Ltd, 1, JEFFREY A. HARNESS, CERTIFY THAT THIS.! PERFORMED IN ACCORDANCE it�WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: " DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 10/2/08 1 2:30 — 6. — 1 2 2:36 6 0 6" 3 2:36 — 4 2:42 6 0 6. 5 2:42 — 6- — 6 2:45 6 0 6. PERCOLATION RATE 1 (MIN.IINCH) PERC, HOLE DIA, 6 (INCHES? 2'0" TEST RUN BETWEEN 6 FT. AND 7 FT. A FOUR HOUR PRESOAK WAS PERFORMED: El YES E NO SOILS LOGGED BY: KYLE MAUS _ PERCOLATION TEST PERFORMED BY: KYLE MAUS PERFORMED BY DEC, Ltd, 1, JEFFREY A. HARNESS, CERTIFY THAT THIS.! PERFORMED IN ACCORDANCE it�WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: " GARNESS ENGINEERING GROUP, Ltd, I - -1 j r" CONSULTANTS& GE14ERAL CONTRACTORS _+:: ...�...< w DEPTH TO GROUNDWATER SOIL IG - PERCOLATION TEW LEGAL DESCRIPTION: FIRE LAKE HEIGHTS; LOT I PERFORMED FOR: KATHi OLMSTEAD DAT DEPTH — 2 *10 *0. (feet) ITEST HC ORGANICS I PROPOSED SOIL CLASSIFICATIONS 2 — :--7:=: GW zz--- ORG 3 GP ML UNE GM CL 4 GC O= - SW MH N•SP CH 5 SM OH Sr DEPTH TO GROUNDWATER DATE DRY - SO4/20-08 DRY 10/2/08 — 2 *10 *0. ----------- 6' DATE READING CLOCK NET TIME WATER LEVEL TIME iMINUTFS, READING FIRE LAKE HEIGHTS; LOT 5 10/2/08 1 — 6" sERVEl3 sr — 2 *10 *0. ----------- 6' 3 6. I PROPOSED N SUBDIVISION 5 UNE TH#2 + + *WATER LEVEL DROPPED TO OWITHIN 6 TO 10 MINUTES. PERCOLATION RATE BETWEEN 1 TO 1.66 MINUTES/INCH APPROXIMATE WATER LINE LOCATION, SCALE ELDORA DRIVE T- - 100' il DATE READING CLOCK NET TIME WATER LEVEL TIME iMINUTFS, READING NET DROP (INCHES) 10/2/08 1 — 6" — 2 *10 *0. ----------- 6' 3 6. — a *10 *0. 6" 5 6. *WATER LEVEL DROPPED TO OWITHIN 6 TO 10 MINUTES. PERCOLATION RATE BETWEEN 1 TO 1.66 MINUTES/INCH ,9L PERCOLATION RATE *1.66 (MIN.ANCH) PERC. HOLE DIA. 6 (INCHES: TEST RUN BETWEEN 6 FT, AND 7 FT. 20 A FOUR HOUR PRESOAK 'WAS PERFORMED: N YES El NO SOILS LOGGED BY: KYLE MAUS _ PERCOLATION TEST PERFORMED BY: KYLE MAUS PERFORMED BY GEG, Ltd, 1, JEFFREY A. GARNESS, CERTIFY THAT THIS WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:. IN ACCORDANCE MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D.051-351-33 Expiration Date: I (— t q' 2 1. GENERAL INFORMATION Complete legal description FIRE LAKE HEIGHTS LOT 16 Location (site address) 18511 COLLETT DRIVE, EAGLE RIVER, AK 99577 Current property owner(s) BRIAN JOHNSON & BRIDGET HANSON Day phone Mailing address Real estate agent 18511 COLLETT DRIVE, EAGLE RIVER, AK 99577 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5 50 1 Waiver Fee $ Date of Payment �q`� a ©12t2 Date of Payment Receipt Number I I Receipt Number COSA # 0 SC -2 21 3 57 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name _CURTIS HUFFMAN, PE Date 7/16/2022 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any estimate of how long a system will function satisfactory /�P•' • !� } for current or future occupants or guarantee that no unseen encroachments, deficiencies or j C3 discrepancies exist can be given by First Water Consulting & FW[.5 �....... .......... .r 6. DSD SIGNATURE • Curtis Huffman System #1 Approved for bedrooms ����F��s•,, cE12sss1 .���� System #2 Approved for bedrooms �l>>F�PROF SS10 P�`"` Disapproved Conditional approval for bedrooms, with the following stipulations: N -WA VV SJT T� E ' ASTf_ ND m Jo -o GRAM oma_ BY Original Certificate Date:_ �— The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory_ Other � � N Legal Description: FIRE LAKE HEIGHTS LT 1B Parcel ID: 051-351-33 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ® Well log is filed with Onsite (or attached) Well production at time of test 0.44 gpm Date drilled 11/1/2012 Water storage tank volume 1000+ gallons Total depth 222 ft Well disinfected for coliform test? ❑ Yes ® No Cased to 102 ft ® Coliform bacteria is Negative ® Sanitary seal is functioning correctly Nitrate mg/L ® Nitrate less than MRL (ND) ® Wires are properly protected Arsenic ug/L ® Arsenic less than MRL (ND) Casing height (above ground) 24 in. F Date of flow test for COSA 7/14/22 Collected by Static water level at beginning of test 141 ft. Date of Sample 7/19/2022 Comments WATER SYSTEM HAS 4 300 -GAL STORAGE TANKS AT BASICALLY 250 GAL EACH FOR PEAK / NORMAL WATER USE. B. TANK DATA C. LIFT STATION Age of tank(s) 10 years ❑ Required maintenance completed Tank type/material SEPTIC / STEEL Age of lift station _ years Measured operating fluid level in septic tank 50" Lift station material ® Standpipes/foundation cleanout per record drawing Comments: Date of pumping 7/12/22 D. ABSORPTION FIELD DATA Which system tested (date installed) 10/30/12 Adequacy test date 7/14/22 ® ALL standpipes present per record drawing Results E Pass For 4 bedrooms Total measured depth from grade 7 ft (max) Fluid depth prior to test 8 in Measured depth to pipe invert from grade 3.2 ft (min) Water added 650 gal ❑ N/A — pressurized field New depth 15 in ❑ Monitor tubes go to bottom of effective. If not, state depth into effective *MOA IR SHOWS 4' ED Elapsed time <1440 min ® Code -required soil cover over field Final fluid depth 7 in ❑ System presoaked Absorption rate 600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: MT/CO AT GRADE. MEASUREMENTS SHOW MISSING 0.2' ED+/- OR APPROXIMATELY. THE SAME AS THE MOA IR 4'ED. NES E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No ft Absorption Field > 5' Community Sewer Manhole/Cleanout > 100' ® Yes if No ft ® Yes if No ft Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No ft Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No ft Neighboring Absorption Fields > 100' Surface Water > 100' ® Yes Animal Containment > 50' ® Yes if No ft ® Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ®Yes if No ft ® Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No ft Property Line > 5' ® Yes if No ft Absorption Field > 5' - ® Yes if No ft Water Main > 10' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Wells on Adjacent Lots: Private Wells > 100' ® Yes if No ft Community Wells > 200' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No _ ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION �o�~`��-,q� I certify that l have determined through field inspections and review 'r .... of Municipal records that the above systems are in conformance with ®'dtj •• ;"� MOA COSA guidelines in effect on this date. '. .. ... ....... s1l vh..- l�.. . .. . . . . . . . . . . . . Curtis Huffman �$l�'F,/••� CE 128991 ..•���� !$ `P�<c�• • 8/18/22. •��� PROFESSVONA„X�. �NNio`4� Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Certificate of On -Site Systems Approval-,(COSA) #-OSC221357 - - - During a recent COSA on-site inspection and test of the potable water supply well on Lot 1B of Fire Lake Heights subdivision, the well's productivity was determined to be .44 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is .41 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. • • Gf L • :-t Municipality of Anchorage 4 On-Site Water and Wastewater Program < ' sv I (907) 343-7904 Certificate of On-Site Systems Approval 051-351-33 ' ) -?7---11 7 Parcel I.D. Expiration Date: 1. GENERAL INFORMATION Complete legal description FIRE LAKE HEIGHTS LOT 1B Location (site address) 18511 COLLETT DRIVE Current Property owner(s) FORECLOSURE Day phone Mailing address Real Estate Agent Day p ;ne 2. TYPE OF DWELLING: �� 4 [. Single Family (w/wo ADU) SEP z � _ ,-: r I� ' � ; III Duplex 1— ❑ Multiple Dwellings (Single Family and/or Duplex) /ti 3. NUMBER OF BEDROOMS: 4 o� Eo � gc" 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well E Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well n Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: NONE Distance: Received b Date: / V`� COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5aL Waiver Fee $ Date of Payment gia ia- Date of Payment Receipt Number _ 0/945D Receipt Number COSA# OSGt W LI Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm C&M ENGINEERING Phone 8545558 Address 30840 PRUDHOE BAY AVE Engineer's Printed Name CHARLES BALZARINI Date 9/24/17 •. ,f- 7„; *: � ; 9TH • * fs 6. DSD SIGNATURE System #1 Approved for Li bedrooms Apd , , LES G BALZARINI System #2 Approved for bedrooms ,48/ • • CE-13854 •4,.,�'' Disapproved �sF9•�/�647 • ��` F�pRO i;SS/l4.NA.� Conditional approval for bedrooms, with the following s,1 �- .;, �.,���°'b► ���ttttttitiirt `eP���.( of An�cyo,,;;;. z pN_S1T�� p wPSER N Original Certificate Date: ( _f C The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory � Other COSA blue sheet r - . If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: FIRE LAKE HEIGHTS LOT 1B Parcel ID:O 5 ) 3/7�_ 33 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# Well Log (YIN) YES 01 Date completed 11/$8/12 Sanitary seal (YIN) YES Wires properly protected (Y/N)YES Total depth 222 ft. Cased to 102 ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 11/26/12 _ 9/9/17 Static water level 125 ft. 132 ft. Well production 0.75 g.p.m. 0.50 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 0.261 mg/L Arsenic ND ug/L Date of sample: 9/11/17 Collected by: C&M ENGINEERING B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 10/30/12 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm(Y/N) N Date of pumping 03/28/17 PumperSANITARY PUMPERS C. ABSORPTION FIELD DATA Date installed 10/30/1x? Soil rating (g.p.d./ft afVt bcirrtrp` 1.2 System type SHALLOW Length 50 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 7.5 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test 9/9/17 Results (Pass/Fail)PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600* gal. New depth 0 in. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 600 g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) NO If yes, give date NA D. LIFT STATION Date installed — Size in gallons Manhole/Access (YIN) --� "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum �— Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot +100 On adjacent lots +100 Absorption field on lot +100 On adjacent lots +100 Public sewer main +100 Public sewer manhole/cleanout +100 Sewer/septic service line +25 Holding tank +75 Animal containment areas +100 Manure/animal excrete storage areas +100 SEPTIC/HOLDING TANK ON LOT TO: Building foundation +5 Property line +5 Absorption field +5 Water main +10 Water service line +10 Surface water +100 Wells on adjacent lots+100 ABSORPTION FIELD ON LOT TO: Property line +10 Building foundation +10 Water main +10 Water Service line+10 Surface water +100 Driveway, parking/vehicle storage +10 Curtain drain +50 Wells on adjacent lots +100 F. COMMENTS HOME WAS VACANT. LEACHFIELD PRECHARPED PRIOR TO TEST. G. ENGINEER'S CERTIFICATION °1' F Ai, ,�" 1 I certify that I have determined through field inspections and 9r :4 review of Municipal records that the above systems are in AM" conformance with MOA COSA guidelines in effect on this date. "� ,»� '�► �` ` ` * 0#4 Engineer's Printed Name CHARLES BALZARINI Date 9/25/17 '40 - RLES G BALZARINI 1G CE-13854 t 4 Jf /7;4717 PROFESSn'x •�; COSA canary sheet_2-6-15 doc • • Municipality of Anchorage 62C Development Services Department Building Safety Division SAFETY On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Certificate of On-Site Systems Approval (COSA) # OSC 171455 During a recent COSA on-site inspection and test of the potable water supply well on Block , Lot 1B of Fire Lake Heights subdivision, the well's productivity was determined to be .5 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4-bedroom residence is .41 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. r , RUSH! RUSH! a 1� 1 iiG E� • '� Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-351-33 Expiration Date: 9ZIZ113 1. GENERAL INFORMATION Complete legal description Fire Lake Heights, Lot 1 B Location (site address) 18511 Collett Drive Eagle River, AK 99577 Current Property owner(s) Troy Davis Homes Day phone 357-9394 Mailing address 165 E. Parks Hwy., Wasilla, AK 99654 Real Estate Agent Day phone 2. TYPE OF DWELLING: Q Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) pk V rcicm5& yv 9wner 3. NUMBER OF BEDROOMS: Four 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual F� Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Received by: _ COSA to be released engineer, unless otherwise requested by the engineer. Date: r 3 COSA Fee $ 1 o `7. w Waiver Fee $ Date of Payment s /[ �/3 Date of Payment Receipt Number 2 Receipt Number COSA # 6SC13116 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE q System #1 Approved fornbedrooms. System #2 Approved for, bedrooms. Disapproved. Conditional approval for Phone 522-7773 bedrooms, with the following stipulations: By: Original Certificate Date: 5 j The Municipality of Ancho age Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System A& Dry Arsenic Advisory Well Flow Adviso X Other COSA blue sheet 9-1-12.doc If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Fire Lake Heights, Lot 1 B A. WELL DATA Well type P If A, B, or C provide PWSID # Date completed 11/1/12 Sanitary seal (Y/N) Y Total depth 222 ft. Cased to 102 ft. FROM WELL LOG Date of test 11/1/12 Parcel ID: 051-351-33 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >18 in. AT INSPECTION Static water level 125 ft. ft. Well production .75 g.p.m, g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate •262 mg/L Arsenic N/D ug/L Date of sample: 4/24/13 Collected by: Anderson Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 10/30/12 Tank size 1,250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA Date installed 10/30/12 Soil rating (g.p.d./ftz or ft2/bdrm) 1.2 GPD/SF System type 5' Wide Length 50.ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 7.5ft. , Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Wateradded gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date ]111111141311l r30NUI Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off' level at in. High water alarm level at Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot > 100 On adjacent lots > 100 Absorption field on lot > On adjacent lots > 100 Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line >25' Holding tank N/A Animal containment areas >50 Manure/animal excrete storage areas >10O r SEPTIC/HOLDING TANK ON LOT TO: Building foundation >51 Property line >5, Water main > Water service line > Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10, Building foundation >10' ' Water Service line >10' Surface water >100 Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that have determined through field inspections and review of Municipal records that the above systems are in conforriiarice *ith MOA COSA guidelines in effect on this date. Engineer's PrAted Name Michael E. Anderson, P.E. Date 4/30/2013 COSA brown sheet_10-10-12.doc Absorption field >5' Surface water >100' Water main >10' Driveway, parking/vehicle storage >25' AV04AH ! ANDERSON 'Z-. CE -4381 0 in. Municipality of Anchorage ep 4 A Development Services Department ss Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # OSC131155 During a recent COSA on-site inspection and test of the potable water supply well on Lot 113 of Fire lake Heights subdivision, the well's productivity was determined to be 0.8 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is 0.42 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. L0 0 J N 0 J Rv z I I I I- 3 PLOT PLAN AS BUILT X SCALE 1" = 40' GRID NW 454 Project No. 13-043 Lang & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 (907) 522-6476 Phone 4000��pp Registered Land Surveyors (907) 522-4625 Fax oop OF A 0p ken®longsurvey.com / jonothanQlongsurvey.com O�P,`�..••••••.•..,gs�oo 1 hereby certify that I have surveyed the following described property: LOT IB, FIRE LAKE HEIGHTS SUBD. (Plat No. 2010-42) �* 49TH Anchorage Recording District, Alaska, and that the improvements situated thereon are a within the property Imes and do not encroach onto the property adjacent thereto, that Q... • .D no improvements on the property lying adjacent thereto encroach on the surveyedQ..,�_....�.t k�,i —. .�.. O premises .and That there are no roadways, transmission lines or other visible Oma„ °. KENNETH LAt� . easements on said property except as indicated hereon. � .�P Dated this the 'd. Day of N�`fi.,I.E� rat'-=, at Anchorage, Alaska OQnPc^p LS 5202.••oy�pO It is the responsibility of the owner to determine the existence of any easements, covenants. or restrictions which do not aooear on the recorded subdivision oloi. A 4\\ROFESS10NAl V o LO I I J° \ I I I I I� } U I � w J I 0 I I I I- 3 PLOT PLAN AS BUILT X SCALE 1" = 40' GRID NW 454 Project No. 13-043 Lang & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 (907) 522-6476 Phone 4000��pp Registered Land Surveyors (907) 522-4625 Fax oop OF A 0p ken®longsurvey.com / jonothanQlongsurvey.com O�P,`�..••••••.•..,gs�oo 1 hereby certify that I have surveyed the following described property: LOT IB, FIRE LAKE HEIGHTS SUBD. (Plat No. 2010-42) �* 49TH Anchorage Recording District, Alaska, and that the improvements situated thereon are a within the property Imes and do not encroach onto the property adjacent thereto, that Q... • .D no improvements on the property lying adjacent thereto encroach on the surveyedQ..,�_....�.t k�,i —. .�.. O premises .and That there are no roadways, transmission lines or other visible Oma„ °. KENNETH LAt� . easements on said property except as indicated hereon. � .�P Dated this the 'd. Day of N�`fi.,I.E� rat'-=, at Anchorage, Alaska OQnPc^p LS 5202.••oy�pO It is the responsibility of the owner to determine the existence of any easements, covenants. or restrictions which do not aooear on the recorded subdivision oloi. A 4\\ROFESS10NAl V o